0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX5-91H

EDSX5-91H

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX5-91H - ABSOLUTE PRESSURE TRANSMITTER - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX5-91H 数据手册
ABSOLUTE PRESSURE TRANSMITTER DATA SHEET The FCX -A III a bsolute pressure transmitter accurately measures absolute pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. FKA...5 FEATURES 1. High accuracy 0 .2% accuracy for all calibrated spans is a standard feature for all AP models covering 1.6kPa {0.016bar} range to 3000kPa {30bar} high pressure range. 0.1% accuracy is available as option. Fuji’s micro-capacitance silicon sensor assures this accuracy for all suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advanced Floating Cell” design which protects the pressure sensor against changes in tempera ture, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART® bilingual communications protocol FCX -AIII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX -AIII. 4. Application flexibility Various options that render the FCX -A III s uitable for almost any process applications include: – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing – Wide selection of materials 5. Burnout current flexibility (Under Scale: 3.2 to 4.0mA, Over Scale: 20.0 to 22.5mA) B urnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 6. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. [ L-Type ] [ T-Type ] SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Span, range, and overrange limit: Span limit [kPa abs] {bar abs} Overrange limit [MPa] {bar} 0.5 {5} 0.5 {5} 1.5 {15} 9 {90} Type Min. FKA FKA FKA FKA 01 02 03 04 1.6 {0.016} 1.6 {0.016} 5 {0.05} 30 {0.3} Max. 16 {0.16} 130 {1.3} 500 {5} 3000 {30} Range limit [kPa abs] {bar abs} 0 to +16 {0 to +0.16} 0 to +130 {0 to +1.3} 0 to +500 {0 to +5} 0 to +3000 {0 to +30} Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – The maximum span of each sensor can be converted to different units using factors as below. 1MPa abs=103kPa abs=10bar abs=10.19716kgf/cm2 abs =145.0377psi abs 1kPa abs =10mbar abs=101.9716mmH2O abs =4.01463inH2O abs=7.50062mmHg abs Output signal: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal. Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. EDSX5-91h Date Aug. 10, 2011 FKA...5 Load limitations: see figure below [Ω] 2000 Load resistance 1474Ω R= E-10.5 (Imax+0.9)x10-3 577Ω Operating area 24V 10 16.35 10.5V Power voltage (DC) 45V 50 E[ V ] 1500 1000 500 250 0 Note: For communication with HHC(1) (Model: FXW), min. of 250 is required. Hazardous locations: SEE TABLE2 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. Damping: Adjustable from HHC or local configurator unit with LCD display. The time constant is adjustable between 0.06 to 32 seconds. Zero elevation/suppression: Zero can be elevated within the specified range limit of each sensor model. Normal/reverse action: Selectable from HHC(1). Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction:Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.0mA to 22.5mA from HHC(1) “Output Underscale”: Adjustable within the range 3.2mA to 4.0mA from HHC(1) 3.2 4 20 22.5 [mA] Over scale Burnout Normal operating range Under scale Probable under range Burnout Probable over range Temperature limit: Ambient: −40 to +85°C (−20 to +80°C for LCD indicator) (−40 to +60°C for arrester option) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. Process: −40 to +85°C for silicone fill sensor Storage: −40 to +90°C Humidity limit: 0 to 100% RH Communication: W ith HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following items can be remotely displayed or configured. Note: HHC’s version must be higher than 7.0 (or FXW 1– 4), for FCX AIII. Local configurator with LCD display (option): Local confi gurator with 3 push button and LCD display can support following items. Items By communication By local configurator with FXW (with 3 push button) Display Tag No. Model No. Serial No. & Software Version Engineering unit Range limit Measuring range Damping Output mode Burnout direction Calibration Output adjust Data Self diagnoses Printer (In case of FXW with printer option) External switch lock Transmitter display Linearize Rerange Saturate current Write protect History – Calibration history – Ambient temperature history v v v v v v v v v v — v v v v v v v v v v v Set v v — v — v v — v v v — — — v v v v v v v — Display v v v v v v v v v v — v v — v v — v v v v v Set v v — v — v v — v v v — — — v v — v v v v — EMC Conformity: EN61326-1: 2006 Output Limits comforming the NAMUR NE43 by order. Loop-check output: Transmitter can be configured to provide constant signal 3.2mA through 22.5mA by HHC(1). (Note) (1) HHC: Hand Held Communicator 2 Performance specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode. Process-wetted parts material: l a i r e t aM edoc t Process t 7 ( i g i d h cover e d oC “ n i symbols”) V H Wetted sensor body Diaphragm Vent/drain Accuracy rating: ( including linearity, hysteresis, and repeatability). (Standard) For spans greater than 1/10 of URL: ±0.2% of span For spans below 1/10 of URL: ± 0.1 + 0.1 0.1 x URL % of span Span 316 316 stainless 316/316L 316L steel (*1) stainless steel stainless steel stainless steel Hastelloy-C 316 stainless 316/316L Hastelloy-C lining steel (*1) stainless steel Note: (*1) SCS14A per JIS G 5121 (equivalent CF8M per ASTM A351/A351M) Remarks: Availability of above material design depends on ranges. Refer to “Code symbols”. ( ) (Option) (code: 21th digit H) (Not available for Max span 16kPa abs, 130kPa abs) For spans greater than 1/10 of URL: ±0.1% of span For spans below 1/10 of URL: ± 0.05 + 0.05 0.1 x URL % of span Span ( ) ±0.2% of upper range limit (URL) for 10 years. Temperature effect: E ffect per 28°C change between the limits of - 40°C and +85°C URL Zero shift: ± 0.125+0.1 % Span Total effect: ± 0.15+0.1 URL % Span Stability: ( ( ) ) Overrange effect: Zero shift; ±0.2% of URL for any overrange to maximum limit Supply voltage effect: Less than 0.005% of calibrated span per 1V Update rate: 60 msec Step response: Time constant: 0.08 s (at 23°C) Dead time: 0.12 s (without electrical damping) Mounting position effect: Zero shift, less than 0.1kPa{1mbar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting zero. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100M at 500V DC. Internal resistance for external field indicator: 12 or less Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with polyester coating (standard), or 316 stainless steel (ASTM CF8M), as specified. Bolts and nut: Cr-Mo alloy (standard), 304 or 316 stainless steel Fill fluid: Silicone oil Mounting bracket: 304 or 316 stainless steel. Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass{weight}: Transmitter approximately 2.9 to 3.4kg without options. Add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option Optional features A plug-in analog indicator (2.5% accuracy) An optional 5-digit LCD meter with engineering unit is also available. Local configurator with LCD display: An optional 5 digits LCD meter with 3 push buttons can support items as using communication with FXW. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2  50µs) Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. 304 stainless steel bolts and nuts, ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Optional tagplate: An extra stainless steel tag for customer tag data is wired to the transmitter. Coating of cell: C ell’s surface is finished with epoxy/ polyurethane double coating. Specify if environment is extremely corrosive. Indicator: Physical specifications Electrical connections: G 1/2, 1/2-14NPT, Pg13.5, or M20 x 1.5 conduit, as specified. Process connections: 1/4-18 NPT or Rc1/4 on 54mm centers, as specified. 3 FKA...5 CODE SYMBOLS Digit 4 Description Process connection Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT Span limit [kPa abs]{bar abs}(*1) 1.6…16 {0.016…0.16} 1.6…130 {0.016…1.3} 5…500 {0.05…5} 30…3000 {0.3…30} Oval flange screw 7/16-20UNF 7/16-20UNF M10 M10 7/16-20UNF 7/16-20UNF 7/16-20UNF M10 M10 7/16-20UNF Process cover 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Conduit connection G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 Diaphragm 316L stainless steel Hast. C 316L stainless steel Hast. C 316L stainless steel Hast. C 316L stainless steel Hast. C Case type T type T type T type T type T type L type L type L type L type L type Wetted cell body Note1 316 stainless steel Hast. C lining 316 stainless steel Hast. C lining 316 stainless steel Hast. C lining 316 stainless steel Hast. C lining Note 12345678 9 10 11 12 13 14 15 21 FKA 0 5 Digit No. of code 5 6 7 8 9 S T V W X 6, 7 1V 1H 2V 2H 3V 3H 4V 4H 9 10 11 Indicator Arrester None None Analog, 0 to 100% linear scale None Analog, custom scale None None Yes Analog, 0 to 100% linear scale Yes Analog, custom scale Yes Digital, 0 to 100% linear scale None Digital, custom scale None Digital, 0 to 100% linear scale Yes Digital, custom scale Yes Digital, 0 to 100% linear scale (Local configurator unit with LCD display) None Digital, custom scale (Local configurator unit with LCD display) None Digital, 0 to 100% linear scale (Local configurator unit with LCD display) Yes Digital, custom scale (Local configurator unit with LCD display) Yes None (for ordinary locations) TIIS, Flameproof (Cable gland seal) (*6) TIIS, Intrinsic safety FM, Flameproof (or explosionproof) (*9) FM, Intrinsic safety and nonincentive FM Combined of flameproof and intrinsic safety (*9) ATEX Flameproof (*8) ATEX Intrinsic safety ATEX Type n ATEX Combined of flameproof and intrinsic safety (*8) IECEx Scheme, Flameproof (*8) IECEx Scheme, Intrinsic safety CSA, Flameproof (or explosionproof) (*9) CSA, Intrinsic safety and nonincentive NEPSI, Flameproof (or exprosionproof) NEPSI, Intrinsic safety NEPSI, Combined of flameproof and intrinsic safety Vent/drain Mounting bracket Standard None Standard Yes, stainless steel (SUS304) Standard Yes, stainless steel (SUS316) Side None Side Yes, stainless steel (SUS304) Side Yes, stainless steel (SUS316) A B D E F H L P Q S 1 2 4 5 Note6 Note9 Note9 Note8 Note8 Note8 Note9 A C G D H V X K P M R T E J F S U A C K D F L Note1: (*1) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance. 4 12345678 9 10 11 12 13 14 15 21 Digit 12 Description Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None (*2) None None Yes Yes None Yes None Yes Yes (*5) Yes Yes Yes Treatment Fill fluid Standard Silicone oil Degreasing Silicone oil NACE specification Silicone oil (7th digit code "T" and 15th digit code "A", "B" are not available) Teflon (gasket) (*3) Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut NACE bolt/nut (ASTM A193 B7M/A194 2HM) NECE bolt/nut (ASTM A320 L7M/A194 2HM) 304 stainless steel bolt/304 stainless steel nut 316 stainless steel bolt/316 stainless steel nut (*4) High accuracy type (*7) Instruction manual attached Opposite Vent/Drain Plug Position Instruction manual attached Instruction manual unattached High accuracy type(*7) Instruction manual unattached Opposite Vent/Drain Plug Position Instruction manual unattached Note FKA 0 5 Digit No. of code Note2 Note5 Note5 Y B M N P Q 13 Y G N 14 15 B Note 3 A B C D E U Note 4 Note 7 H C L T P 21 Note 7 Note2: (*2) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select "Yes". Note3: (*3) In case of tropical use, select stainless bolts and nuts. Note4: (*4) If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. Note5: (*5) Not available for 10th digit code “C”. Note6: (*6) Available for 4th digit code "S". Note7: (*7) Available for 6th digit code "3", "4". Note8: (*8) Available for 4th digit code "6", "8", "T", "W". Note9: (*9) Available for 4th digit code "6", "T". ACCESSORIES (Model FFP refer to Data Sheet No. EDS6, 128) Converts process connection to 1/2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Hand held communicator: (Model FXW, refer to Data Sheet No. EDS 8-47) Oval flanges: ORDERING INFOMATION When ordering this instrument, specify. 1. CODE SYMBOLS 2. Measuring range. 3. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Hold / Overscale / Underscale Unless other wise specified, output hold function is supplied. 4. Indication method (indicated value and unit) in case of the actual scale (code D, H, P S on 9th digit). , 5. Tag No. (up to 14 alphanumerical characters), if required. 5 FKA...5 OUTLINE DIAGRAM (Unit:mm) . VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE3) IN CASE OF 4TH DIGIT CODE "6" WITH ANALOG IND. WITH DIGITAL IND. "A" PRESS. CONN. IN CASE OF 4TH DIGIT CODE "5,7,8,9" 10 8 (21) (11) ZERO ADJ. SCREW MTG. PIPE JIS 50A (2B) 41 EARTH TERMINAL ZERO 110 38 VENT/DRAIN PLUG "B" CONDUIT CONN. 37 168 (171) 17 127 20 NOTE2) 57 4 HOLES 9 DIA. U-BOLT M8 DETAIL "A" (PRESS. CONN.) φ18.5 H 2.5 DETAIL "B" (CONDUIT CONN.) (229) NOTE2) OVAL FLANGE SCREW SEE TABLE1 φ15 SIDE VENT(OPTION) φ81 100 SCS13 70 E L.P 10 SEE TABLE1 D SEE TABLE1 4-M8×12 H.P 4th digit of the code symbols 5 6 7 8 9 Conduit conn. D G 1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 E 18 16 10.5 16 10.5 F 2 4 4.5 4 4.5 Press. conn. H Rc1/4 1/4-18N T P 1/4-18N T P 1/4-18N T P 1/4-18N T P Oval frange screw 7/16-20UNF SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 M10 SCREW DEPTH15 M10 SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 27 70 104 TABLE 1 CONNECTION DIAGRAM + −/CK− CK+ 75 20 NOTE2) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H,M,T" NOTE3) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). 6 41.3 F 226 8 . VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE3) IN CASE OF 4TH DIGIT CODE "S,V,W,X" "A" PRESS. CONN. ZERO ADJ. SCREW 41 10 8 MTG. PIPE JIS 50A (2B) IN CASE OF 4TH DIGIT CODE "T" φ81 103 103 70 41 RO 38 57 37 172 4 HOLES 9 DIA. U-BOLT M8 (175) VENT/DRAIN PLUG WITH DIGITAL IND. NOTE2) EARTH TERMINAL OVAL FLANGE SCREW SEE TABLE1 SIDE VENT(OPTION) 198 (201) NOTE2) DETAIL C φ13 φ33.5 G1/2 + −/CK− CK+ 75 17 "C" CONDUIT CONN. (21) (11) 41 126 43 "B" CONDUIT CONN. WITH ANALOG IND. DETAIL "A" (PRESS. CONN.) φ18.5 2.5 H DETAIL "B" (CONDUIT CONN.) φ15 120 8 F 10 SEE TABLE1 D SEE TABLE1 E L.P H.P 4-M8×12 4th digit of the code symbols S T V W X Conduit conn. D G 1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 E 18 16 10.5 16 10.5 F 2 4 4.5 4 4.5 Press. conn. H Rc1/4 1/4-18N T P 1/4-18N T P 1/4-18N T P 1/4-18N T P Oval frange screw 7/16-20UNF SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 M10 SCREW DEPTH15 M10 SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 27 70 104 TABLE 1 OPTION PARTS FOR FLAMEPROOF OF TIIS (JAPAN) 10th digit code C (Cable gland type) NOTE1) G1/2 CONNECTION DIAGRAM 19 106 CABLE GLAND NOTE1) IN CASE OF 10TH CODE “C”φ11 CABLE IS SUITBLE. , NOTE2) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H" NOTE3) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). 20 41.3 φ81 7 FKA...5 TABLE 2 Authorities ATEX Intrinsic safety Ex II 1 G Ex ia IIC T5 Tamb = –40°C to +50°C Ex ia IIC T4 Tamb = –40°C to +70°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Factory Mutual Class I II III Div.1 Groups A, B, C, D, E, F G , T4 Entity Type 4X Model code 9th digit A,B,D L,P ,1,2 Q,S,4,5 E,F ,H Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C CSA Authorities ATEX Flameproof Ex II 2 GD Ex d IIC T6 IP66/67 T85°C Tamb = −40°C to +65°C Ex d IIC T5 IP66/67 T100°C Tamb = −40°C to +85°C Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F G , T6 Type 4X Tamb max = +60°C Class I Div.1 Groups C, D Class II Div.1 Groups E, F G , Class III Div.1 Note) “Seal Not Required” enclosure is allowed. TIIS Ex do IIB+H2 T4 Tamb max = +60°C Maximum process temp. = +120°C Ex d IIC T5 IP66/67 Tamb = −40°C to +85°C Ex d IIC T6 IP66/67 Tamb = −40°C to +65°C Ex d IIB+H2 T6 Tamb = −40°C to +60°C Type n Nonincendive Ex II 3 GD EEx nL IIC T5 Tamb = –40°C to +50°C EEx nL IIC T4 Tamb = –40°C to +70°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=25.18nF Li=0.694mH , Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH , EEx nAL IIC T5 Tamb = –40°C to +50°C EEx nAL IIC T4 Tamb = –40°C to +70°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W Factory Mutual (pending) Class I II III Div.2 Groups A, B, C, D, F G , T4 Entity Type 4X Model code 9th digit A,B,D L,P ,1,2 Q,S,4,5 E,F ,H CSA Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C Factory Mutual Entity Parameters: Vmax=28V, Imax=94.3mA, Pi=0.66W, Ci=35.98nF Li=0.694mH , CSA Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F G , Class III Div.1 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Imax=94.3mA, Ci=25nF (Without Arrester), Ci=36nF (With Arrester), Li=0.6mH (Without analog meter), Li=0.7mH (With analog meter) Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=38.4nF Li=0.694mH , Ex ia IIC T4 Tamb = –40°C to +70°C Ex ia IIC T5 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Ex ia IIC T4 Ex d IIB+H2 T6 / Ex ia IIC T4 Model code 9th digit A,B,D L,P ,1,2 Q,S,4,5 E,F ,H 13th digit Y,G,N Y,G,N Y,G,N Y,G,N Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C IECEx Scheme NEPSI Authorities ATEX TIIS IECEx Scheme NEPSI Entity Parameters: Ui=42.4V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH , Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F G , Class III Div.2 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Ci=25.18nF (Without Arrester), Ci=35.98nF (With Arrester), Li=0.694mH Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. P rinted in Japan
EDSX5-91H 价格&库存

很抱歉,暂时无法提供与“EDSX5-91H”相匹配的价格&库存,您可以联系我们找货

免费人工找货