0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX5-92H

EDSX5-92H

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX5-92H - PRESSURE TRANSMITTER - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX5-92H 数据手册
PRESSURE TRANSMITTER DATA SHEET The FCX – A III p ressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. FKG...5 FEATURES 1. High accuracy up to ±0.04% 0.065% accuracy as standard, 0.04% accuracy as option. Fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advance Floating Cell” design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART® bilingual communications protocol FCX–AIII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–AIII. 4. Application flexibility Various options that render the FCX–AIII suitable for almost any process applications include: – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing 5. Burnout current flexibility (Under Scale: 3.2 to 4.0mA, Over Scale: 20.0 to 22.5mA) B urnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 6. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. [ L-Type ] [ T-Type ] Span, range and overrange limit: Span limit [kPa] {bar} Type Min. F KG 01 FKG 02 FKG 03 FKG 04 FKG 05 1.3 {0.013} 5 {0.05} 30 {0.3} 100 {1} 500 {5} Max. 130 {1.3} 500 {5} 3000 {30} 10000 {100} 50000 {500} Range limit [kPa] {bar} Lower limit Upper limit −100 {−1} −100 {−1} −100 {−1} −100 {−1} −100 {−1} 130 {1.3} 500 {5} 3000 {30} 10000 {100} 50000 {500} Overrange limit [MPa] {bar} 1 {10} 1.5 {15} 9 {90} 15 {150} 75 {750} Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower range limit (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at below 60°C – Conversion factors to different units; 1 MPa=103 kPa=10bar=10.19716kgf/cm2= 145.0377psi 1kPa=10mbar=101.9716mmH2O =4.01463inH2O Load limitations: see figure below [Ω] 2000 Load resistance 1474Ω R= E-10.5 (Imax+0.9)x10-3 577Ω Operating area 24V 10 16.35 10.5V Power voltage (DC) 45V 50 E[ V ] 1500 1000 500 250 0 SPECIFICATIONS Functional specifications Service: Output signal: Power supply: Liquid, gas, or vapour 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal. Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. Note: For communication with HHC(1) (Model: FXW), min. of 250  required. EDSX5-92h Date Aug. 10, 2011 FKG...5 Hazardous locations: (Under an application) SEE TABLE2 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. Damping: Adjustable from HHC or local configurator unit with LCD display. The time constant is adjustable between 0.06 to 32 seconds. Zero elevation/suppression: Z ero can be elevated or suppressed within the specified range limit of each sensor model. Normal/reverse action: Selectable from HHC(1). Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale”or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.0mA to 22.5mA from HHC(1) “Output Underscale”: Adjustable within the range 3.2mA to 4.0mA from HHC 3.2 4 20 22.5 [mA] Over scale Burnout Normal operating range Under scale Probable under range Burnout Probable over range Local configurator with LCD display (option): Local confi gurator with 3 push button and LCD display can support following items. Items By communication By local configurator with FXW (with 3 push button) Display Tag No. Model No. Serial No. & Software Version Engineering unit Range limit Measuring range Damping Output mode Burnout direction Calibration Output adjust Data Self diagnoses Printer (In case of FXW with printer option) External switch lock Transmitter display Linearize Rerange Saturate current Write protect History – Calibration history – Ambient temperature history v v v v v v v v v v — v v v v v v v v v v v Set v v — v — v v — v v v — — — v v v v v v v — Display v v v v v v v v v v — v v — v v — v v v v v Set v v — v — v v — v v v — — — v v — v v v v — EMC Conformity: EN61326-1: 2006 Performance specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode. Output limits conforming to NAMUR NE43 by order. Loop-check output: Transmitter can be configured to provide constant signal 3.2mA through 22.5mA by HHC. Temperature limit: Ambient: −40 to +85°C (−20 to +80°C for LCD indicator) (−40 to +60°C for arrester option) (−10 to +60°C for fluorinated oil fill transmitter) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. Process: −40 to +100°C for silicone fill sensor −20 to +80°C for fluorinated oil fill sensor Storage: −40 to +90°C Humidity limit: 0 to 100% RH Communication: W ith HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following items can be remotely displayed or configured. Note: HHC’s version must be higher than 7.0 (or FXW 1– 4), for FCX AIII. (Note) (1) HHC: Hand Held Communicator 2 Accuracy rating: ( including linearity, hysteresis, and repeatability) Max span below 10000kPa model: For spans greater than 1/10 of URL: ±0.065% of span or ±0.04% of span (21th digit: H) For spans below 1/10 of URL: 0.1  URL ± 0.015+0.05 % of span Span Max span 50000kPa model: For spans greater than 1/10 of URL: ±0.1% of span For spans below 1/10 of URL: 0.1  URL ± 0.05+0.05 % of span Span Stability: ±0.1% of upper range limit (URL) for 10 years. Temperature effect: E ffects per 28°C change between the limits of −40°C and +85°C URL Zero shift: ±(0.075+0.0125 span )% URL Total effect: ±(0.095+0.0125 )% span Overrange effect: Z ero shift; 0.2% of URL for any overrange to maximum limit Supply voltage effect: Less than 0.005% of calibrated span per 1V Update rate: 60 msec Step response: Time constant: 0.08s (at 23°C) Dead time: approximately 0.12s (without electrical damping) ( ( ) ) Mounting position effect: Zero shift, less than 0.1kPa {1m bar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100M at 500V DC. Internal resistance for external field indicator: 12 or less Optional features Indicator: A plug-in analog indicator (2.5% accuracy) An optional 5-digit LCD meter with engineering unit is also available. Local configurator with LCD display: An optional 5 digits LCD meter with 3 push buttons can support items as using communication with FXW. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: The fill fluid is fluorinated oil. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Vacuum service: Special silicone oil and filling procedure are applied. See Fig.1. Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell’s surface is finished with epoxy/polyurethane double coating. Specify if environment is extermely corrosive. Silicone oil (Code:Y,G,N) Silicone oil (Code:R) [kPa abs] {mbar abs} 101 {1010} Operating pressure Operating area 20 {200} Physical specifications Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. Process connections: 1/4-18 NPT or Rc1/4 on 54mm centers, as specified. Meet DIN 19213 Process-wetted parts material: l e t e symbols) V W J a i r e t aM doc Process t 7 ( i g i d h cover d oC n i 316 stainless steel(*1) 316 stainless steel(*1) 316 stainless steel(*1) Wetted sensor body Diaphragm Vent/drain H M T 316L stainless 316 stainless steel steel 316 stainless Hastelloy-C steel 316L stainless 316 stainless steel steel +Au coating Hastelloy-C 316 stainless Hastelloy-C lining steel(*1) Monel lining Monel 316 stainless steel(*1) Tantalum Tantalum 316 stainless lining steel(*1) 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Note: *(1) ASTM CF8M Remark: Availability of above material design depends on ranges. Refer to “Code symbols” . Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with polyester coating (standard), or 316 stainless steel (SCS14 per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard), 304 or 316 stainless steel (630 stainless steel for 50MPa unit). Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 or 316 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass {weight}: Transmitter approximately 2.9 to 3.4kg without options. Add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option 4 {40} 2.7 {27} None-operating area −40 −15 60 85 120 Process temperature [°C ] Fig. 1 Relation between process temperature and operating pressure 3 FKG...5 CODE SYMBOLS 12345678 9 10 11 12 13 14 15 21 Digit 4 Description Oval flange Process screw connection 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF Span limit Process cover [kPa]{bar}(*2) 1.3…130 316 stainless steel {0.013…1.3} 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel SCS14 316 stainless steel Conduit connection G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 Diaphragm 316L stainless steel Hast. C 316L stainless steel +Au coating Hast. C Monel Tantalum 316L stainless steel Hast. C 316L stainless steel +Au coating Hast. C Monel Tantalum 316L stainless steel Hast. C 316L stainless steel +Au coating Hast. C Monel Tantalum 316L stainless steel Hast. C 316L stainless steel +Au coating Hast. C Monel Tantalum 316L stainless steel Hast. C 316L stainless steel +Au coating Case type T type T type T type T type T type L type L type L type L type L type Wetted cell body 316 stainless steel SUS316 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel SUS316 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel SUS316 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel SUS316 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel SUS316 316 stainless steel Note F KG 0 5 Digit No. of code Note 1 Note 1 Note 1 Note 1 5 6 7 8 9 S T V W X 6, 7 Note 2 1V 1W 1J 1H 1M 1T 2V 2W 2J 2H 2M 2T 3V 3W 3J 3H 3M 3T 4V 4W 4J 4H 4M 4T 5V 5W 5J 5…500 {0.05…5} 30…3000 {0.3…30} 100…10000 {1…100} 500…50000 {5…500} 9 Indicator None Analog, 0 to 100% linear scale Analog, custom scale None Analog, 0 to 100% linear scale Analog, custom scale Digital, 0 to 100% linear scale Digital, custom scale Digital, 0 to 100% linear scale Digital, custom scale Digital, 0 to 100% linear scale (Local configurator unit with LCD display) Digital, custom scale (Local configurator unit with LCD display) Digital, 0 to 100% linear scale (Local configurator unit with LCD display) Digital, custom scale (Local configurator unit with LCD display) Arrester None None None Yes Yes Yes None None Yes Yes None A B D E F H L P Q S 1 2 None 4 Yes 5 Yes Note 1 : (*1) Note 2 : (*2) For 50MPa {500bar} units, M12 is provided rather than M10. 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance. 4 12345678 9 10 11 12 13 14 15 21 Digit 10 11 12 13 14 15 21 Description None (for ordinary locations) TIIS, Flameproof (Cable gland seal) (*6) TIIS, Intrinsic safety FM, Flameproof (or explosionproof) (*9) FM, Intrinsic safety and nonincentive FM Combined of flameproof and intrinsic safety (*9) ATEX Flameproof (*8) ATEX Intrinsic safety ATEX Type n ATEX Combined of flameproof and intrinsic safety (*8) IECEx Scheme, Flameproof (*8) IECEx Scheme, Intrinsic safety CSA, Flameproof (or explosionproof) (*9) CSA, Intrinsic safety and nonincentive NEPSI, Flameproof (or exprosionproof) NEPSI, Intrinsic safety NEPSI, Combined of flameproof and intrinsic safety Vent/drain Mounting bracket Process connection Standard None Standard Standard Yes, SUS304 Standard Standard Yes, SUS316 Standard Side None Standard Side Yes, SUS304 Standard Side Yes, SUS316 Standard Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None (*3) None None Yes Yes None Yes None Yes Yes (*5) Yes Yes Yes Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code "V", "W", "J" only) Chlorine service Fluorinated oil (7th digit code "H", "T") NACE specification Silicone oil (Not available for 6th digit code "5", 7th digit code "T", 15th digit code "A", "B") Vacuum service Silicone oil for vacuum use Teflon (gasket) Vent Drain plug type (*10) Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Standard Standard Cr-Mo alloy hexagon bolt/nut Standard NACE bolt/nut (ASTM A193 B7M/A194 2HM) NACE bolt/nut (ASTM A320 L7M/A194 2HM) (*11) Standard Standard 304 stainless steel bolt/304 stainless steel nut Standard 630 stainless steel bolt/304 stainless steel nut (*12) Standard 316 stainless steel bolt/316 stainless steel nut (*11) (*4) High accuracy type (*11) Instruction manual attached Opposite Vent/Drain Plug Position Instruction manual attached Instruction manual unattached Opposite Vent/Drain Plug Position Instruction manual unattached Note F KG 0 5 A C G D H V X K P M R T E J F S U Digit No. of code Note 6 Note 9 Note 9 Note 8 Note 8 Note 8 Note 9 A C K D F L Note 3 Note 5 Note 5 Y B M N P Q Y W G A D N R B Note 10 A B C D E F U H C L P Note 11 Note 11 Note 11 Note 12 Note 11 Note 4 Note 11 Note3: (*3) Customer tag number can be engraved on standartd stainless steel name plate. If extra tag plate is required, select "Yes". Note4: (*4) If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. Note5: (*5) Not available for 10th digit code "C". Note6: (*6) Available for 4th digit code "S". Note8: Note9: Note10: Note11: Note12: (*8) Available for 4th digit code "6", "8", "T", "W". (*9) Available for 4th digit code "6", "T". (*10) In case of tropical use, select stainless bolts and nuts. (*11) Not available for 6th digit code "5". (*12) Available for 6th digit code "5". ACCESSORIES ( Model FFP, refer to Data Sheet No. EDS6-128) Converts process connection to 1/2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Hand-held communicator: ( Model FXW, refer to Data Sheet No. EDS8-47) Oval flanges: ORDERING INFORMATION When ordering this instrument, specify. 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occured in the transmitter. Hold/Overscale/Overscale Unless otherwise specified, output hold function is supplied. 4. Indication method (indicated value and unit) in case of the actual scale (code D,H,P,S on 9th digit). 5. Tag No.(up to 14 alphanumerical characters), if required. 5 FKG...5 OUTLINE DIAGRAM (Unit:mm) MTG. PIPE JIS 50A (2B) VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE2) IN CASE OF 4TH DIGIT CODE "S,V,W,X" IN CASE OF 4TH DIGIT CODE "T" 10 "A" PRESS. CONN. 41 8 ZERO ADJ. SCREW 103 φ81 103 120 41 U-BOLT M8 38 57 37 VENT/DRAIN PLUG 172 "B" CONDUIT CONN. (21) (11) 126 WITH DIGITAL IND. 41 43 4 HOLES 9 DIA. (175) WITH ANALOG IND. NOTE3) EARTH TERMINAL DETAIL "A" (PRESS. CONN.) φ18.5 2.5 H φ15 198 φ13 φ33.5 G1/2 + −/CK− CK+ 75 17 DETAIL "B" (CONDUIT CONN.) (201)NOTE3) OVAL FLANGE SCREW SEE TABLE1 SIDE VENT(OPTION) 8 F 10 SEE TABLE1 D SEE TABLE1 E L.P H.P 4-M8×12 4th digit of the code symbols S T V W X Conduit conn. D G 1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 E 18 16 10.5 16 10.5 F 2 4 4.5 4 4.5 Press. conn. H Rc1/4 1/4-18N T P 1/4-18N T P 1/4-18N T P 1/4-18N T P Oval frange screw 7/16-20UNF SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 M10 SCREW DEPTH15 M10 SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 70 27 104 TABLE 1 OPTION PARTS FOR FLAMEPROOF OF TIIS (JAPAN) 10th digit code C (Cable gland type) NOTE1) G1/2 DETAIL C CONNECTION DIAGRAM 19 106 "C" CONDUIT CONN. CABLE GLAND NOTE1) IN CASE OF 10TH CODE “C”φ11 CABLE IS SUITBLE. , NOTE2) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). NOTE3) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H,M,T" 20 6 41.3 φ81 70 MTG. PIPE JIS 50A (2B) VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE2) IN CASE OF 4TH DIGIT CODE "6" WITH ANALOG IND. WITH DIGITAL IND. "A" PRESS. CONN. IN CASE OF 4TH DIGIT CODE "5,7,8,9" 10 8 41 EARTH TERMINAL (21) (11) ZERO ADJ. SCREW 110 U-BOLT M8 38 57 37 "B" CONDUIT CONN. VENT/DRAIN PLUG 4 HOLES 9 DIA. 168 (171) NOTE3) 17 127 20 DETAIL "A" (PRESS. CONN.) φ18.5 H 2.5 DETAIL "B" (CONDUIT CONN.) (229) NOTE3) OVAL FLANGE SCREW SEE TABLE1 SIDE VENT(OPTION) 226 φ15 8 E 10 SEE TABLE1 D SEE TABLE1 4-M8×12 L.P H.P 4th digit of the code symbols 5 6 7 8 9 Conduit conn. D G 1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 E 18 16 10.5 16 10.5 F 2 4 4.5 4 4.5 Press. conn. H Rc1/4 1/4-18N T P 1/4-18N T P 1/4-18N T P 1/4-18N T P Oval frange screw 7/16-20UNF SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 M10 SCREW DEPTH15 M10 SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 70 104 27 TABLE 1 CONNECTION DIAGRAM + −/CK− CK+ 75 20 NOTE2) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). NOTE3) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H,M,T" 41.3 F φ81 100 70 7 FKG...5 TABLE 2 Authorities ATEX Intrinsic safety Ex II 1 G Ex ia IIC T5 Tamb = –40°C to +50°C Ex ia IIC T4 Tamb = –40°C to +70°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Factory Mutual Class I II III Div.1 Groups A, B, C, D, E, F G , T4 Entity Type 4X Model code 9th digit A,B,D L,P ,1,2 Q,S,4,5 E,F ,H − CSA Authorities ATEX Flameproof Ex II 2 GD Ex d IIC T6 IP66/67 T85°C Tamb = −40°C to +65°C Ex d IIC T5 IP66/67 T100°C Tamb = −40°C to +85°C Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F G , T6 Type 4X Tamb max = +60°C Class I Div.1 Groups C, D Class II Div.1 Groups E, F G , Class III Div.1 Note) “Seal Not Required” enclosure is allowed. TIIS Ex do IIB+H2 T4 Tamb max = +60°C Maximum process temp. = +120°C Ex d IIC T5 IP66/67 Tamb = −40°C to +85°C Ex d IIC T6 IP66/67 Tamb = −40°C to +65°C Ex d IIB+H2 T6 Tamb = −40°C to +60°C Type n Nonincendive Ex II 3 GD EEx nL IIC T5 Tamb = −40°C to +50°C EEx nL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=25.18nF Li=0.694mH , Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH , EEx nAL IIC T5 Tamb = −40°C to +50°C EEx nAL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W Factory Mutual (pending) Class I II III Div.2 Groups A, B, C, D, F G , T4 Entity Type 4X Model code 9th digit A,B,D L,P ,1,2 Q,S,4,5 E,F ,H − CSA 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C Factory Mutual 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C Entity Parameters: Vmax=28V, Imax=94.3mA, Pi=0.66W, Ci=35.98nF Li=0.694mH , CSA Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F G , Class III Div.1 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Imax=94.3mA, Ci=25nF (Without Arrester), Ci=36nF (With Arrester),Li=0.6mH (Without analog meter), Li=0.7mH (With analog meter) Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=38.4nF Li=0.694mH , Ex ia IIC T4 Tamb = –40°C to +70°C Ex ia IIC T5 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Ex ia IIC T4 Ex d IIB+H2 T6 / Ex ia IIC T4 Model code 9th digit A,B,D L,P ,1,2 Q,S,4,5 E,F ,H − 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C IECEx Scheme NEPSI Authorities ATEX TIIS IECEx Scheme NEPSI Entity Parameters: Ui=42.4V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH , Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F G , Class III Div.2 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Ci=25.18nF (Without Arrester), Ci=35.98nF (With Arrester), Li=0.694mH International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan
EDSX5-92H 价格&库存

很抱歉,暂时无法提供与“EDSX5-92H”相匹配的价格&库存,您可以联系我们找货

免费人工找货