EDSX6-117I

EDSX6-117I

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX6-117I - REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX6-117I 数据手册
REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER DATA SHEET The FCX – A 2 differential pressure transmitter accurately measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. Totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. FKD...4 FEATURES 1. High accuracy 0.2% accuracy for all calibrated spans is a standard feature for all DP models covering 0.32kPa {3.2mbar} range to 500kPa {5bar} high differential pressure range. 0.1% accuracy is available as option. Fuji’s microcapacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART® bilingual communications protocol and FOUNDATION™ fieldbus and Profibus™ compatibility FCX–A2 series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART ® compatible devices can communicate with FCX–A2. Further, by upgrading electronics FOUNDATION™ fieldbus and Profibus™ are also available. 4. Application flexibility Various options that render the FCX – A2 suitable for almost any process applications include: – Analog indicator at either the electronics side or terminal side – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing – Wide selection of materials – High temperature, high vacuum seals 5. Programmable output Linearization Function In addition to Linear and Square Root, output signal can be freely programmable. (Up to 14 compensated points at approximation.) 6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA, Over Scale: 20.8 to 21.6mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Static pressure, span, and range limit: Type F KD F KD F KD 3 5 6 Static pressure Span limit [kPa] (m bar} Max. Min. 0.32 { 3.2 } 1.3 { 13 } 5 { 50 } 32 { 320 } 130 { 1300 } 500 { 5000} Range limit [kPa] {m bar} +/– 32 {+/– 320} +/– 130 {+/– 1300} +/– 500 {+/– 5000} } Up to flange rating Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower limit of static pressure (vacuum limit), Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: Atmospheric pressure – The maximum span of each sensor can be converted to different units using factors as below. 1MPa =103kPa=10bar=10.19716kgf/cm2 =145.0377psi 1kPa=10mbar=101.976mmH2O=4.01463H2O Overrange limit: To maximum static pressure limit Output signal: 4 to 20mA DC (linear or square root) with digital signal superimposed on the 4 to 20mA signal Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. EDSX6-117i Date Jun. 1, 2006 FKD...4 Load limitations: see figure below [Ω] 2000 1533Ω Authorities ATEX Intrinsic safety Ex II 1 GD EEx ia IIC T5 Tamb = –40°C to +40°C EEx ia IIC T4 Tamb = –40°C to +80°C Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.134mH Load resistance 1500 1000 500 250 0 10 600Ω Operating area 24V 16.1 10.5V Power voltage 45V 50 [V] Factory Mutual Class I II III Div.1 Groups A, B, C, D, E, F, G T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P,M,1,2,3 Q,S,N,4,5,6 E,F,G,H,K – 13th digit Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K W,A,D Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C –10°C to +60°C Note: For communication with HHC(1) (Model: FXW), min. of 250Ω is required. Entity Parameters: Vmax=42.4V, Imax=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH CSA Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F, G Class III Div.1 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Imax=93mA, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=32.6nF, Li=1.134mH Ex ia IIC T4 IP66/67 Tamb = –40°C to +70°C Ex ia IIC T5 IP66/67 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=0.033µF, Li=1.034mH Hazardous locations: Authorities ATEX Flameproof Ex II 2 GD EEx d IIC T6 IP66/67 T85°C Tamb = – 40°C to +65°C EEx d IIC T5 IP66/67 T100°C Tamb = – 40°C to +85°C Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F, G T6 Type 4X Tamb max = +60°C Class I Div.1 Groups C, D Class II Div.1 Groups E, F, G Class III Div.1 Note) “Seal Not Required” enclosure is allowed. TIIS Ex do IIB+H2 T4 Tamb max = +55°C Maximum process temp. = +120°C Ex d IIC T5 IP66/67 pending Tamb = – 40°C to +85°C Ex d IIC T6 IP66/67 pending Tamb = – 40°C to +65°C Factory Mutual TIIS CSA IECEx Scheme /SAA IECEx Scheme /SAA 2 Authorities ATEX Type n Nonincendive Ex II 3 GD EEx nL IIC T5 Tamb = –40°C to +40°C EEx nL IIC T4 Tamb = –40°C to +80°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=27nF, Li=1.134mH Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH EEx nAL IIC T5 Tamb = –40°C to +40°C EEx nAL IIC T4 Tamb = –40°C to +80°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W “Output Underscale”: Adjustable within the range 3.2mA to 3.8mA from HHC(1) 3.2 3.8 4 20 20.8 21.6 [mA] Over scale Burnout Normal operating range Under scale Probable under range Burnout Probable over range Factory Mutual Class I II III Div.2 Groups A, B, C, D, F, G T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P,M,1,2,3 Q,S,N,4,5,6 E,F,G,H,K – 13th digit Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K W,A,D Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C –10°C to +60°C Loop-check output: Transmitter can be configured to provide constant signal 3.8mA through 21.6mA by HHC(1). Temperature limit: Ambient: – 40 to + 85°C (– 20 to + 80°C for LCD indicator) (– 40 to + 60°C for arrester option) (– 10 to + 60°C for fluorinated oil fill transmitter) (– 10 to + 85°C for silicone oil “H”, “S”, “K”) (+ 20 to + 85°C for silicone oil “J”, “T”) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. Process: Fill fluid Fluorinated oil Silicone oil Code in the 13th digit of “Code symbols” W, A and D H J Y and G S T K Process temperature – 20 to 120°C – 15 to 250°C 85 to 300°C – 40 to 120°C – 15 to 250°C 85 to 300°C – 15 to 200°C 0.13kPa abs {1mmHg abs} or more 2.7kPa abs {20mmHg abs} Lower limit of static press. Atmospheric pressure CSA Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F, G Class III Div.2 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH – TIIS IECEx Scheme /SAA – Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw (span odjustment is not available with 9th digit code “L, P, M, Q, S, N”). Damping: Adjustable from HHC or local adjustment unit with LCD display. The time constant is adjustable between 0.12 to 32 seconds. Zero elevation/suppression: –100% to +100% of URL Normal/reverse action: Selectable from HHC(1) Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.8mA to 21.6mA from HHC(1) Storage: – 40 to +90°C Humidity limit: 0 to 100% RH Communication: With HHC(1) ( Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely displayed or reconfigured. Note: HHC’s version must be more than 6.0 (or FXW 1– 3), for FCXA2. Items Tag No. Model No. Serial No. Engineering unit Range limit Measuring range Damping Output mode Linear Square root Burnout direction Calibration Output adjust Data Self diagnoses Printer External switch lock Transmitter display Linearize Rerange (Note) (1) HHC: Hand Held Communicator Display v v v v v v v v v v v — v v — v v v v Set v v — v — v v v v v v v — — — v v v v 3 FKD...4 Programmable output linearization function: Output signal can be characterized with “14 points linear approximation function” from HHC(1). EMC Conformity: EN61326 (Note) (1) HHC: Hand Held Communicator Physical specifications Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. And 1-conduit or 2-conduit, as specified. Process connections: JIS, ANSI, or DIN raised face flanges. JIS: 10K80A, 10K100A, 30K80A, or 30K100A ANSI: 150LB 3", 150LB 4", 300LB 3", or 300LB 4" DIN: PN40 DN80 or PN16 DN100 See OUTLINE DIAGRAM for detailed dimensions. Diaphragm extension: 0, 50, 100, 150, or 200mm as specified. (See model code. Extended diaphragm is available only with 316L stainless steel or Hastelloy-C diaphragm) Process-wetted parts material: Diaphragm: 316L stainless steel, HastelloyC, Monel, Tantalum, Titanium or Zirconium Flange face:316 stainless steel, HastelloyC lining Monel lining, or Tantalum lining Extension: 316 stainless steel or HastelloyC Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating (standard), or 316 stainless steel (SCS14 per JIS G5121), as specified. Capillary: In case of 11th code “D, E, F, L, M, N, P”, PVC armored stainless steel. In case of 13th code “Q, R, S, T, V, W, X”, stainless steel armored stainless steel. Mounting flange: 304 stainless steel or carbon steel Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting Mass {weight}: Transmitter approximately 15kg without options. Add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 1.5kg per 50mm extension of diaphragm Performance specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode. Accuracy rating: (including linearity, hysteresis, and repeatability) (Standard) For spans greater than 1/10 of URL: 0.2% of span For spans below 1/10 of URL: 0.1 × URL ± 0.1+0.1 % of span Span (Option) (Code; 21th digit H,K) For spans greater than 1/10 of URL: 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.2% of upper range limit (URL) for 3 years. Temperature effect (*): Effects per 28°C change between the limits of – 40°C and +85°C (Standard) Zero shift: ± 0.35% of URL Total effect: ± 0.5% of URL (Option) (Code; 21th digit J,K) Zero shift: ± 0.3% of URL Total effect: ± 0.4% of URL ( ( ) ) Note: * Excluding effect by temperature difference between the seals. Static pressure effect: Zero shift; 0.2% of URL for flange rating pressure Span shift: – 0.2% of calibrated span for flange rating pressure Overrange effect: Zero shift; 0.1% of URL for flange rating pressure Supply voltage effect: Less than 0.005% fo calibrated span per 1V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. (Classification: 2-abc: 0.2% span per SAMA PMC 33.1) Update period: 120 msec *) Step response: (without electrical damping) Range code “3” “5” “6” Time constant (*) 2 s 0.2 s 1.7 s 1.7 s *) Faster response is available as option (maximum update rate: 25 times per second). Dead time (*) Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Turn-on time: 4 sec. Internal resistance for external field indicator: 12Ω or less 4 [kPa abs] {mbar abs} Silicone (Code Y,G) Silicone (Code S) Silicone (Code T) [kPa abs] {mbar abs} Sealing liquid:Silicone (Code K) 101 {1010} 101 {1010} Operating pressure Operating area Operating pressure 53.3 {533} Operating area 13.3 {133} Non-operating area 2.7 {27} –40 –15 60 85 120 Process temperature[°C ] 200 230 250 300 0.27 {2.7} 0.13 {1.3} –15 100 Process temperature[°C ] 200 Fig. 1 Relation between process temperature and operating pressure Fig. 2 Relation between process temperature and operating pressure Optional features A plug-in analog indicator (2.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. An optional 5-digit LCD meter with engineering unit is also available. Local adjustment unit with LCD display: An optional 5-digit LCD meter with Zero/ Span adjustment function, loop-check function and damping adjustment function, is available. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: Oil-free procedures as above. Includes fluorinated oil for fill. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. Vacuum service: Special silicone oil and filling procedure are applied. See Fig. 1, Fig. 2. Optional tag plate: An extra stainless steel tag for customer tag data is wired to the transmitter. Coating of cell: Cell’s surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive. Indicator: ACCESSORIES Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS 8-47) Z/S board: Parts No.=ZZPFCX4-A070 When Z/S board is mounted on the FCX– A2 a mplifier unit, external adjustment screw will be available for zero and span adjustment. 5 FKD...4 CODE SYMBOLS 12345678 9 10 11 12 13 14 15 21 Digit 4 Description G 1/2 (×1) 1/2-14NPT (×1) Combination with 12th digit code "C, E, P, Q" are not Pg13.5 (×1) available. M20 × 1.5 (×1) G 1/2 (×2) 1/2-14NPT (×2) Pg13.5 (×2) M20 × 1.5 (×2) Flange size and rating Mounting flange JIS 10K 80A 304 stainless JIS 10K 100A steel JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN16/40 DN80 DIN PN16 DN100 JIS 20K 80A ANSI/JPI 600LB 3B JIS 10K 80A Carbon steel JIS 10K 100A JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN16/40 DN80 DIN PN16 DN100 JIS 10K 80A 316 stainless ANSI/JPI 150LB 3B steel ANSI/JPI 150LB 4B ANSI/JPI 300LB 3B ANSI/JPI 300LB 4B ANSI/JPI 600LB 3B 3 inch wafer None 4 inch wafer (wafer type) 0.32.... 32 {3.2..... 320} 1.3...... 130 {13...... 1300} 5......... 500 {50...... 5000} Flange face Diaph. extension [mm] Diaphragm 316 stainless 0 316L stainless steel 50 steel 100 (*2) 150 200 0 Hastelloy-C Hastelloy-C 50 100 150 200 0 316 stainless stell 316L stainless +Au coating 0 Monel Monel 0 Tantalum Tantalum 0 Titanium Titanium (*3) 0 Zirconium Zirconium 1/40 Note FKD A B C D S T V W 4 0 Digit No. of code 5 0 1 2 3 4 5 6 7 8 9 M R A B C D E F G H J K S T U V W X P Q Note 1 3 5 6 6 7 Note 2 V A B C D H F G K L J M T P R Note 3 Note 1: (*1) Note 2: (*2) Note 3: (*3) 100: 1 turn down is possible, but should be used at a span greater than of the maximum span for better performance. Available for 13th digit code "S", "T", "K" and 5th digit code "1", "3", "5", "7", "B", "D", "F", "H", "K", "Q", "U", "W". Available for 6th code "2", "3" and 5th code "0", "2", "4", "6", "8", "A", "C", "E", "G", "J", "P", "M", "R", "S", "T", "W". 6 12345678 9 10 11 12 13 14 15 21 Digit Description 9 Indicator Arrester None None Analog, 0 to 100% linear scale None Analog, 0 to 100% sq. root scale None Analog, custom scale None Analog, double scale (linear and sq. root) None Z/S board attached. None Yes Analog, 0 to 100% linear scale Yes Analog, 0 to 100% sq. root scale Yes Analog, custom scale Yes Analog, double scale (linear and sq. root) Yes Digital, 0 to 100% None Digital, custom scale None Digital, 0 to 100% square root None Digital, 0 to 100% Yes Digital, custom scale Yes Digital, 0 to 100% square root Yes Digital, 0 to 100% (Local adjustment unit with LCD display) None Digital, custom scale (Local adjustment unit with LCD display) None Digital, 0 to 100% square root (Local adjustment unit with LCD display) None Digital, 0 to 100% (Local adjustment unit with LCD display) Yes Digital, custom scale (Local adjustment unit with LCD display) Yes Digital, 0 to 100% square root (Local adjustment unit with LCD display) Yes 10 None (for ordinary locations) TIIS, Flameproof (Conduit seal) (Available for 4th digit code "A", "S") TIIS, Flameproof (Cable gland seal) (Available for 4th digit code "A", "S") FM, Flameproof (or explosionproof) (Available for 4th digit code "B", "T") CSA, Flameproof (or explosionproof) (Available for 4th digit code "B", "T") ATEX, Flameproof IECEx Scheme/SAA, Flameproof (Approval pending) TIIS, Intrinsic safety FM, Intrinsic safety and nonincendive CSA, Intrinsic safety and nonincendive ATEX, Intrinsic safety ATEX, Type n IECEx Scheme/SAA, Intrinsic safety FM, Combined of Flameproof and Intrinsic safety 11 Capillary Mounting bracket armor of capilary 1.5 m 304 Stainless steel PVC (*4) 3 304 Stainless steel PVC (*4) 5 304 Stainless steel PVC (*4) 6 304 Stainless steel PVC (*4) 7 304 Stainless steel PVC (*4) 8 304 Stainless steel PVC (*4) 10 304 Stainless steel PVC (*4) 1.5 304 Stainless steel Stainless steel (*5) 3 304 Stainless steel Stainless steel (*5) 5 304 Stainless steel Stainless steel (*5) 6 304 Stainless steel Stainless steel (*5) 7 304 Stainless steel Stainless steel (*4) 8 304 Stainless steel Stainless steel (*4) 10 304 Stainless steel Stainless steel (*4) 12 Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None (*6) Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes Note 4: (*4) Available for 13th digit code "Y, W, G, A, D". Inquire about in case of 13th other code. Note 5: (*5) Available for all 13th digit code. Note 6: (*6) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select "Yes". Note FKD 4 0 Digit No. of code A B C D J E F G H K L P M Q S N 1 2 3 4 5 6 A B C D E X R G H J K P T V Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 5 Note 5 Note 5 Note 5 Note 4 Note 4 Note 4 D E L F M N P Q R S T V W X Note 6 Y B C E M N P Q 7 FKD...4 12345678 9 10 11 12 13 14 15 21 Note Description Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code "V", "A", "B", "C", "D"and "J") Chlorine service Fluorinated oil (7th digit code "H", "F", "G", "K", "L"and"T") High temp. 250°C Silicone oil 7th digit code "V", "A", "B", "C", "D", "H", "F", "G", "K" and "L" High temp. 300°C Silicone oil (*7) High temp. and vacuum (250°C) Silicone oil Note 7 High temp. and vacuum (300°C) Silicone oil 7th digit code "V", "A", "B", "C", and "D" High temp. and high vacuum Silicone oil 14 None Yes (Available for 5th digit code "0", "2", "4", "6", "8", "A", "C", "E", "G", "J", "P", "M", "R", "S", "T", "U", "X" and 7th digit code "V", "H", "M", "T", "P", "R". Not available for the 13th digit code "H", "J", "S", "T", "K".) (*8) Note 8 21 High accuracy type Instruction manual attached Low temperature effect type Instruction manual attached H+J Instruction manual attached Instruction manual unattached High accuracy type Instruction manual unattached Low temperature effect type Instruction manual unattached T+U Instruction manual unattached Note 7: (*7) Treatment; Standard Note 8: (*8) If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. Digit 13 FKD 4 0 Digit No. of code Y W G A D H J S T K Y C H J K L T U V 8 ORDERING INFORMATION The product conforms to the requirements of the Electromagnetic compatibility Directive 94/9/EC as detailed within the technical construction file number TN513035. The applicable standards used to demonstrate compliance are : EMI (Emission) Frequency range MHz 30 to 230 230 to 1000 EN61326 : 1997 Class A (standard for Industrial Location) Limits 40dB (µV/m) quasi peak, measured at 10m distance 47dB (µV/m) quasi peak, measured at 10m distance Reference standard CISPR16-1 and CISPR16-2 When ordering this instrument, specify: 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Hold / Overscale (21.6mA) / Underscale (3.2mA) Unless otherwise specified, output hold function is supplied. 4. Output mode (linear or square root output) Unless otherwise specified, output mode is linear. 5. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S on 9th digit). 6. Tag No. (up to 26 alphanumerical characters), if required. EMI (Immunity) Phenomenon Electrostatic discharge EN61326: 1997 Annex A (standard for Industrial Location) Test value Basic standard EN61000-4-2 Performance criteria B 4kV (Contact) 8kV (Air) 80 to 1000MHz Electromagnetic 10V/m field 80%AM (1kHz) Rated power frequency magnetic field Burst 30A/m 50Hz 2kV 5kHz 1.2µs/50µs 1kV (Line to line) 2kV (Line to ground) 0.15 to 80MHz 3V 80%AM (1kHz) EN61000-4-3 A EN61000-4-8 A EN61000-4-4 B Surge EN61000-4-5 B Conducted RF EN61000-4-6 A Note) Definition of performance criteria A: During testing, normal performance within the specification limits. B: During testing, temporary degradation, or loss of function or performance which is self-recovering. 9 FKD...4 OUTLINE DIAGRAM (Unit:mm) In case of 4th digit code "A.B.C.D.E" MTG. pipe JIS 50A (2B) U-bolt M8 In case of 4th digit code "T" Zero ADJ. screw 94.5 10 8 In case of 4th digit code "S.V.W.X" Fastener (Flamproof only) Up 105 ø80 52.5 105 Down 38 58 4 holes 9 dia. 28 201 (27) 88 104 "A" Conduit conn. With field IND. "B" Conduit conn. Note) Cable gland (option) Inner of gasket No flange is attached in case of 5th digit code "P,Q". P øD øF øG øH 20 L t 270 48 43 Earth tarminal Electronics unit KM 17 222 Detail "A" (Conduit donn.) ø15 Detail "B" ø13 J See table 1 CONDUIT CONN. 4TH DIGIT CODE J K M A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V D, W Pg13.5 M20 1.5 8 16 4.5 5 G1/2 S L.P. 2-M8 12 H.P. S Sensor unit 54 70 120 CONNECTION DIAGRAM Table 1 5TH DIGIT OF THE CODE SYMBOLS 0, A, S M 2, C 1, B 3, D 4, E, T 6, G, V R, X 5, F, U 7, H, W 8, J 9, K øD 185 200 210 210 240 191 210 210 229 254 200 220 øE 150 160 170 175 195 152.5 168 168 190.5 200 160 180 øF øG 126 126 126 151 151 126 126 126 151 151 126 151 100 100 100 103 103 100 100 100 103 103 100 103 øH 73 73 73 96 96 73 73 73 96 96 73 96 t 38 42 48 38 52 44 49 52 44 52 44 40 P 116 116 116 141 141 116 116 116 141 141 116 141 N-øh 8-19 8-23 8-23 8-19 8-25 4-20 8-23 8-23 8-20 8-23 8-18 8-18 (FLANGE) JIS-10K-80A JIS-20K-80A JIS-30K-80A JIS-10K-100A JIS-30K-100A ANSI 150LB 3B ANSI 300LB 3B ANSI 600LB 3B ANSI 150LB 4B ANSI 300LB 4B DIN PN40 DN80 DIN PN16 DN100 øE ø80 70 N holes h dia. CK CK 7TH DIGIT CODE V, J, H, M, T, P, R A,F B,G C,K D,L L 0 50 100 150 200 MASS.APPROX. (kg) 14∼19.5 15∼30.5 15.5∼31 16∼31.5 16.5∼32 11TH DIGIT S 11TH DIGIT S (m) (m) CODE CODE D, Q E, R L, S F, T 1.5 3 5 6 M, V N, W P, X 7 8 10 Note) Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. 10 11 FKD...4 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDSX6-117I 价格&库存

很抱歉,暂时无法提供与“EDSX6-117I”相匹配的价格&库存,您可以联系我们找货

免费人工找货