DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER
DATA SHEET
The FCX–A III d ifferential pressure (fl ow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality.
FKC...5
FEATURES
1. High accuracy up to ±0.04% 0.065% accuracy as standard, 0.04% accuracy as option. Fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART® bilingual communications protocol FCX–AIII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–AIII. 4. Application flexibility Various options that render the FCX–AIII suitable for almost any process applications include. – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing – Wide selection of materials 5. Programmable output Linearization Function In addition to Linear and Square Root, output signal can be freely programmable. (Up to 14 compensated points at approximation.) 6. Burnout current flexibility (Under Scale: 3.2 to 4.0mA, Over Scale: 20.0 to 22.5mA) B urnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.
[ L-Type ]
[ T-Type ]
SPECIFICATIONS
Functional specifications
Service: Liquid, gas, or vapour Static pressure, span, and range limit:
Type F KC 11 FKC 22 FKC 33 FKC 35 FKC 36 FKC 38 FKC 43 FKC 45 FKC 46 FKC 48 FKC 49 Static pressure [MPa] {bar} −0.1 to + 0.2 {−1 to + 2} −0.1 to + 10 {−1 to + 100 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 42 {−1 to + 420 } −0.1 to + 42 {−1 to + 420 } −0.1 to + 42 {−1 to + 420 } −0.1 to + 30 {−1 to + 300 } −0.1 to + 30 {−1 to + 300 } Span limit [kPa] {m bar} Min. 0.1 1 0.1 { 1 0.32 { 3.2 1.3 { 13 5 { 50 30 { 300 0.32 { 3.2 1.3 { 13 5 { 50 30 { 300 500 {5000 { } } } } } } } } } } } { Max. 1 10 } 6 { 60 } 32 { 320 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } 32 { 320 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } 20000 {200000 } Range limit [kPa] {m bar} +/− 1 { +/− 10 } +/− 6 { +/− 60 } +/− 32 { +/− 320 } +/− 130 { +/− 1300 } +/− 500 { +/− 5000 } +/− 3000 { +/− 30000 } +/− 32 { +/− 320 } +/− 130 { +/− 1300 } +/− 500 { +/− 5000 } +/− 3000 { +/− 30000 } {+20000,−10000} { +200000,−100000}
Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications.
– Lower limit of static pressure (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at temperature below 60°C – The maximum span of each sensor can be converted to different units using factors as below. 1MPa =103KPa=10bar=10.19716kgf/cm2 =145.0377psi 1kpa=10mbar=101.9716mmH2O=4.01463inH2O
EDSX6-134h
Date Aug. 10, 2011
FKC...5
Over range limit: To maximum static pressure limit Output signal: 4 to 20mA DC (linear or square root) with digital signal superimposed on the 4 to 20mA signal Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. Load limitations: see figure below
[Ω] 2000 Load resistance 1474Ω R= E-10.5 (Imax+0.9)x10-3 577Ω Operating area 24V 10 16.35 10.5V Power voltage (DC) 45V 50 E[ V ]
1500 1000 500 250 0
Note: For communication with HHC(1) (Model: FXW), min. of 250 Ω required.
Hazardous locations: (Under an application) SEE TABLE2 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. Damping: Adjustable from HHC or local configurator unit with LCD display. The time constant is adjustable between 0.06 to 32 seconds. Zero elevation/suppression: −100% to +100% of URL Normal/reverse action: Selectable from HHC(1) Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.0mA to 22.5mA from HHC(1) “Output Underscale”: Adjustable within the range 3.2mA to 4.0mA from HHC(1)
3.2 4 20 22.5 [mA] Over scale Burnout Normal operating range Under scale Probable under range Burnout Probable over range
Temperature limit: Ambient: −40 to +85°C (−20 to +80°C for LCD indicator) (−40 to +60°C for arrester option) (−10 to +60°C for fluorinated oil filled transmitters) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. Process: −40 to +120°C for silicone fill sensor −20 to +80°C for fluorinated oil fill sensor Storage: −40 to +90°C Humidity limit: 0 to 100% RH Communication: W ith HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following items can be remotely displayed or configured. Note: HHC’s version must be higher than 7.0 (or FXW 1− 4), for FCX–AIII. Local configurator with LCD display (option): Local confi gurator with 3 push button and LCD display can support following items.
Items By communication By local configurator with FXW (with 3 push button) Display Tag No. Model No. Serial No. & Software Version Engineering unit Range limit Measuring range Damping Output mode Burnout direction Calibration Output adjust Data Self diagnoses Printer (In case of FXW with printer option) External switch lock Transmitter display Linearize Rerange Saturate current Write protect History – Calibration history – Ambient temperature history Linear Square root v v v v v v v v v v v — v v v v v v v v v v v Set v v — v — v v v v v v v — — — v v v v v v v — Display v v v v v v v v v v v — v v — v v — v v v v v Set v v — v — v v v v v v v — — — v v — v v v v —
Programmable output linearization function: Output signal can be characterized with “14 points linear approximation function” from HHC(1). EMC Conformity: EN61326-1: 2006
Output limits conforming to NAMUR NE43 by order. Loop-check output: Transmitter can be configured to provide constant signal 3.2mA through 22.5mA by HHC(1).
(Note) (1) HHC: Hand Held Communicator
2
Performance specifications for linear output
Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode.
Performance specifications for square root output
Accuracy rating:
Span Output 50 to 100% 20 to 50% 10 to 20% over 0.1 × URL ±0.065 % ±0.163 % ±0.325 % below 0.1 × URL ±(0.015+0.05 × 0.1 × URL/Span)% ±2.5 × (0.015+0.05 × 0.1 × URL/Span)% ±5 × (0.015+0.05 × 0.1 × URL/Span)%
Accuracy rating: ( including linearity, hysteresis, and repeatability) Max span 32kPa to 3000kPa model: For spans greater than 1/10 of URL: ±0.065% of span or ±0.04% of span (21th digit: H) For spans below 1/10 of URL: 0.1 × URL ± 0.015+0.05 % of span Span Max span 20MPa model: For spans greater than 5Mpa: ±0.1% of span For spans below 5MPa: 5MPa ± 0.05+0.05 % of span Span Max span 1kPa, 6kPa model: For spans greater than 1/10 of URL: ±0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ±0.1% of upper range limit (URL) for 10 years for 6th digit code 3, 5, 6, 8 and 9. Temperature effect: Effects per 28°C change between the limits of −40°C and +85°C
Max span 1kPa, 6kPa model:
Output 50 to 100% 20 to 50% 10 to 20% Accuracy ±0.1 % ±0.25% ±0.5 %
(
)
(
)
Temperature effect: Effects per 28°C change between the lim-its of −40°C and +85°C
Range code Shift at 20% output point ± 0.375+0.25 URL %/28°C Span URL ± 0.24+0.03125 %/28°C Span
(
)
“1” and “2” “3” through “9”
(
)
(
)
Low flow cut-off: Customer configurable for any point between 0 to 20% of output
Range code (6th digit in Code symbols) “1”/1kPa {10mbar} “2”/6kPa {60mbar} “3”/32kPa {320mbar} “5”/130kPa {1300mbar} “6”/500kPa {5000mbar} “8”/3000 kPa {30000mbar} “9”/20000kPa {200000mbar}
Zero shift
Total effect
Performance specifications common for both atpt modes
± 0.125+0.1 URL % Span
(
)
± 0.15+0.1 URL % Span
(
)
Supply voltage effect: Less than 0.005% of calibrated span per 1V Update rate: 60 msec Step response: (without electrical damping)
URL URL ± 0.075+0.0125 Span % ± 0.095+0.0125 Span %
(
)
(
)
Range code (6th digit in code symbols) “1” “2” “3” “5” through “8”
Time constant (at 23°C) 0.33 s 0.3 s
Dead time
0.12 s 0.12 s 0.08 s
Static pressure effect:
Static pressure code (5th digit in Code symbols) “1” / 1kPa {10m bar} sensor “2” / 6kPa {60 m bar} sensor “2” “3” “4” Zero shift (% of URL) ±0.2% / 0.2MPa {2bar} ±0.2% / 3.2MPa {32bar} ±0.035% / 6.9MPa {69bar} ±0.2% / 6.9Mpa {69bar} FKC49
Overrange effect:
Static pressure code (5th digit in Code symbols) “1” / 1kPa {10m bar} sensor “2” / 6kPa {60m bar} sensor “2” “3” “3” “4” “4” Zero shift (% of URL) ±0.3% / 0.2MPa {2bar} ±0.1% / 3.2MPa {32bar} ±0.1% / 10MPa {100bar} ±0.1% / 16MPa {160bar} FKC3 5,6,8 ±0.15% / 16MPa {160bar} FKC33 ±0.25% / 42MPa {420 bar} FKC4 3,5,6,8 ±0.2% / 10MPa {100bar} FKC49
Mounting position effect: Zero shift, less than 0.12kPa {1.2m bar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Internal resistance for external field indicator: 12Ω or less
3
FKC...5
Physical specifications
Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. Process connections: 1/4-18 NPT or Rc1/4 on 54mm centers, as specified. Meets DIN 19213. Process-wetted parts material:
l e t e symbols) V W H J a i r e t aM doc Process t 7 ( i g i d h cover d oC n i 316 stainless steel(*1) 316 stainless steel(*1) 316 stainless steel(*1) 316 stainless steel(*1)
Optional features
A plug-in analog indicator (2.5% accuracy). An optional 5-digit LCD meter with engineering unit is also available. Local configurator with LCD display: An optional 5 digits LCD meter with 3 push buttons can support items as using communication with FXW. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: The fill fluid is fluorinated oil. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Static pressure rating for code “3” (16 MPa) is degraded to 10MPa. Vacuum service: Special silicone oil and filling procedure are applied. See Fig. 1. Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: C ell’s surface is finished with epoxy/ polyurethane double coating. Specify if environment is extremely corrosive. Indicator:
Diaphragm
Wetted sensor body
Vent/drain
316L stainless 316 stainless steel steel Hastelloy-C 316 stainless steel Hastelloy-C Hastelloy-C lining 316L stainless 316 stainless steel steel +Au coating Monel Tantalum Monel lining Tantalum lining
316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel
M T
316 stainless steel(*1) 316 stainless steel(*1)
316 stainless steel 316 stainless steel
Notes: * (1) ASTM CF8M Remark: Availability of above material design depends on ranges and static pressure. Refer to “Code symbols” .
Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with polyester coating (standard), or 316 stainless steel (SCS14 per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard), 304 or 316 stainless steel (for static pressure code “1”, “2”, and “3” only), or 630 stainless steel (for static pressure code “3” and “4” only). Static pressure rating for code “3” with 304 and 316 stainless steel bolts is degraded to 10MPa. Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 or 316 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm(JIS 50A) pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass{weight}: Transmitter approximately 3.1 to 3.6kg without options. Add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option
Silicone oil (Code:Y,G,N) Silicone oil (Code:R) [kPa abs] {mbar abs} 101 {1010} Operating pressure
20 {200}
Operating area
4 {40} 2.7 {27}
None-operating area −40 −15 60 85 120
Process temperature [°C] Fig. 1 Relation between process temperature and operating pressure
4
CODE SYMBOLS
12345678 9 10 11 12 13 14 15 21
Conduit Oval flange Process Case type connection connection screw 7/16-20UNF T type G1/2 Rc1/4 7/16-20UNF 1/2-14NPT 1/4-18NPT T type 1/4-18NPT T type M10 (or M12)(*1) Pg 13.5 1/4-18NPT T type M10 (or M12)(*1) M20×1.5 7/16-20UNF 1/4-18NPT T type Pg 13.5 7/16-20UNF L type G1/2 Rc1/4 7/16-20UNF 1/2-14NPT 1/4-18NPT L type 1/4-18NPT L type M10 (or M12)(*1) Pg 13.5 1/4-18NPT L type M10 (or M12)(*1) M20×1.5 7/16-20UNF 1/4-18NPT L type Pg 13.5 5, 6, 7 Static Span limit (*2) Process Diaphragm Wetted pressure cover cell body [MPa] [kPa] {bar} (m bar) –0.1 to 316 stainless steel 316L stainless steel 316 stainless steel 0.1…1 +0.2 SUS316 316 stainless steel Hast. C {1…10} {–1 to+2} 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C –0.1 to+10 0.1…6 316 stainless steel 316L stainless steel 316 stainless steel {–1 to 100} {1…60} SUS316 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C –0.1 to+16 0.32…32 316 stainless steel 316L stainless steel 316 stainless steel {–1 to+160} {3.2…320} SUS316 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel Tantalum lining 316 stainless steel Tantalum 1.3…130 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {13…1300} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel Tantalum lining 316 stainless steel Tantalum 5…500 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {50…5000} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel Tantalum lining 316 stainless steel Tantalum 30…3000 316 stainless steel 316L stainless steel 316 stainless steel {300…30000} 316 stainless steel 316L stainless steel 316 stainless steel +Au coating –0.1 to+42 0.32…32 316 stainless steel 316L stainless steel 316 stainless steel {–1 to+420} {3.2…320} SUS316 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel 1.3…130 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {13…1300} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel 5…500 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {50…5000} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel –0.1 to+30 30…3000 316 stainless steel 316L stainless steel 316 stainless steel {–1 to+300} {300…30000} 316 stainless steel 316L stainless steel 316 stainless steel +Au coating 500…20000 316 stainless steel 316L stainless steel 316 stainless steel {5000…200000}
Digit 4
Description
Note
FKC
5
Digit No. of code
Note 1 Note 1
Note 1 Note 1
5 6 7 8 9 S T V W X
Note 2
11V 11W 11J 11H 22V 22W 22J 22H 33V 33W 33J 33H 33M 33T 35V 35W 35J 35H 35M 35T 36V 36W 36J 36H 36M 36T 38V 38J 43V 43W 43J 43H 43M 45V 45W 45J 45H 45M 46V 46W 46J 46H 46M 48V 48J 49V
Note 1: (*1) The thread is M12, if 42MPa {420bar} static pressure is specified. Note 2: (*2) 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance.
5
FKC...5
12345678
9 10 11 12 13
14 15
21
Digit 9
Description Indicator Arrester None None Analog, 0 to 100% linear scale None Analog, 0 to 100% sq. root scale (*3) None Analog, custom scale None Analog, double scale (Linear and sq. root) None None Yes Analog, 0 to 100% linear scale Yes Analog, 0 to 100% sq. root scale (*3) Yes Analog, custom scale Yes Analog, double scale (Linear and sq. root) Yes Digital, 0 to 100% linear scale None Digital, custom scale None Digital 0 to 100% square root scale None Digital, 0 to 100% linear scale Yes Digital, custom scale Yes Digital 0 to 100% square root scale Yes Digital, 0 to 100% linear scale (Local configurator unit with LCD display) None Digital, custom scale (Local configurator unit with LCD display) None Digital, 0 to 100% square root scale (Local configurator unit with LCD display) None Digital, 0 to 100% linear scale (Local configurator unit with LCD display) Yes Digital, custom scale (Local configurator unit with LCD display) Yes Digital, 0 to 100% square root scale (Local configurator unit with LCD display) Yes None (for ordinary locations) TIIS, Flameproof (Cable gland seal) (*12) TIIS, Intrinsic safety FM, Flameproof (or explosionproof) (*15) FM, Intrinsic safety and nonincentive FM Combined of flameproof and intrinsic safety (*15) ATEX Flameproof (*14) ATEX Intrinsic safety ATEX Type n ATEX Combined of flameproof and intrinsic safety (*14) IECEx Scheme, Flameproof (*14) IECEx Scheme, Intrinsic safety CSA, Flameproof (or explosionproof) (*15) CSA, Intrinsic safety and nonincentive NEPSI, Flameproof (or exprosionproof) NEPSI, Intrinsic safety NEPSI, Combined of flameproof and intrinsic safety Vent/drain Mounting bracket Process connection Standard None Standard Specify “A” or “C” or “K” , Standard Yes, SUS304 for the 7th digit code Standard Standard Yes, SUS316 “B” “L, or “U” Standard ,” Side None Standard Side Yes, SUS304 Standard Side Yes, SUS316 Standard Extra SS tag plate Stainless steel elec, housing Coating of cell None None None Yes None None None None Yes (*4) Yes None Yes None Yes Yes (*11) Yes Yes Yes Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code “V” “W” “J” only) , , Chlorine service Fluorinated oil (7th digit code “H” “T”) , NACE specification Silicone oil (Not available for 7th digit code “T” and 15th digit code “A” “B”) , Vacuum service Silicone oil for vacuum use Teflon (gasket)
Note
FKC
5
Digit No. of code
Note 3
Note 3
A B C D J E F G H K L P M Q S N 1 2 3 4 5 6
10
Note 12 Note 15 Note 15 Note 14
Note 14 Note 14 Note 15
A C G D H V X K P M R T E J F S U
11
A C K D F L
12
Note 4
Note 11 Note 11
Y B M N P Q
13
Y W G A D N R B
14
Note 3: (*3) In case of square root output mode, square root scale is not available. Note 4: (*4) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes” .
6
12345678
9 10 11 12 13
14 15
21
Digit 15
Description
21
(*8) Vent Drain plug type Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Standard Cr-Mo alloy hexagon bolt/nut Standard Note 5 NACE bolt/nut (ASTM A193 B7M/A194 2HM) (*5) Standard NACE bolt/nut (ASTM A320 L7M/A194 2HM) Standard Note 6 304 stainless steel bolt/304 stainless steel nut (*6) Standard Note 7 630 stainless steel bolt/304 stainless steel nut (*7) Standard Note 6 316 stainless steel bolt/316 stainless steel nut (*6) Standard Note 9 (*9) Note 10 High accuracy type (*10) Instruction manual attached Opposite Vent/Drain Plug Position Instruction manual attached Instruction manual unattached Opposite Vent/Drain Plug Position Instruction manual unattached Static pressure should be −0.1 to +10MPa {−1 to +100bar}. Available for 5th digit code “1” “2” “3” In case of stainless steel bolt ,,. with 5th digit code “3” static pressure should be −0.1 to +10MPa {−1 to + 100bar}. , Available for 5th digit code “3” “4” ,. In case of tropical use, select stainless bolts and nuts. If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. Available for 5th digit code “3” “4” and 6th digit code “3” to “8” , . Not available for 10th digit code ”C” . Available for 4th digit code "S". Available for 4th digit code "6", "8", "T", "W". Available for 4th digit code "6", "T".
Note Note 8
FKC
5 A B C D E F U H C L P
Digit No. of code
Note 5: (*5) Note 6: (*6) Note 7: (*7) Note 8: (*8) Note 9: (*9) Note 10: Note 11: Note 12: Note 14: Note 15: (*10) (*11) (*12) (*14) (*15)
7
FKC...5
ACCESSORIES
Oval flanges: ( Model FFP, refer to Data Sheet No. EDS6-128) Converts process connection to 1/2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel.
ORDERING INFORMATION
When ordering this instrument, specify: 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Hold / Overscale / Underscale Unless otherwise specified, output hold function is supplied. 4. Output mode (linear or square root output) Unless otherwise specified, output mode is linear. 5. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S on 9th digit). 6. Tag No. (up to 14 alphanumerical characters), if required.
Equalizing valves: (Model FFN, refer to Data Sheet No. EDS6-128) Available in Carbon steel or in 316 stainless steel and in pressure rating 16MPa or 42MPa. Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS 8-47)
8
OUTLINE DIAGRAM (Unit:mm)
.
VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE2)
IN CASE OF 4TH DIGIT CODE "S,V,W,X"
IN CASE OF 4TH DIGIT CODE "T"
MTG. PIPE JIS 50A (2B) 41
"A" PRESS. CONN. 10 ZERO ADJ. SCREW 8
φ81
120
41
103
103
ZERO
RO
38 57 4 HOLES 9 DIA. U-BOLT M8 37 (21) 195 (198) VENT/DRAIN PLUG (11)
"B" CONDUIT CONN.
WITH ANALOG IND. 41
126
126 43
WITH DIGITAL IND. NOTE3) EARTH TERMINAL
DETAIL "A" (PRESS. CONN.) 2.5 φ18.5 H
DETAIL "B" (CONDUIT CONN.) φ15
SIDE VENT(OPTION)
8
E
F
L.P 4-M8×12
H.P
10 SEE TABLE1
D SEE TABLE1
4th digit of the code symbols S T V W X
Conduit conn. D G 1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 E 18 16 10.5 16 10.5 F 2 4 4.5 4 4.5
Press. conn. H Rc1/4 1/4-18N T P 1/4-18N T P 1/4-18N T P 1/4-18N T P
Oval frange screw 7/16-20UNF SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 M10 SCREW DEPTH15 M10 SCREW DEPTH15 7/16-20UNF SCREW DEPTH15
54 70 104
TABLE 1
OPTION PARTS FOR FLAMEPROOF OF TIIS (JAPAN) 10th digit code C (Cable gland type) NOTE1)
DETAIL C φ13 φ33.5
CONNECTION DIAGRAM
+ −/CK− CK+
G1/2
75
106 20
"C" CONDUIT CONN. G1/2
CABLE GLAND
NOTE1) IN CASE OF 10TH CODE “C”φ11 CABLE IS SUITBLE. , NOTE2) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). NOTE3) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H,M,T"
17
19
41.3
221 (224) NOTE3)
OVAL FLANGE SCREW SEE TABLE1
φ81
70
9
FKC...5
.
VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE2)
IN CASE OF 4TH DIGIT CODE "6" IN CASE OF 4TH DIGIT CODE "5,7,8,9"
WITH ANALOG IND.
WITH DIGITAL IND.
MTG. PIPE JIS 50A (2B) 41
10
"A" PRESS. CONN.
EARTH TERMINAL
8
(21) (11)
ZERO ADJ. SCREW
ZERO
100
127
U-BOLT M8
38 57 37 191 (194) 17 127 20 VENT/DRAIN PLUG NOTE3) "B" CONDUIT CONN.
4 HOLES 9 DIA.
DETAIL "A" (PRESS. CONN.) φ18.5 H 2.5
DETAIL "B" (CONDUIT CONN.) OVAL FLANGE SCREW SEE TABLE1 φ15 NOTE3) SIDE VENT(OPTION) 8 41.3 L.P 4-M8×12 H.P 54 70 104 F 248(251)
10 SEE TABLE1
D SEE TABLE1
4th digit of the code symbols 5 6 7 8 9
Conduit conn. D G 1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 E 18 16 10.5 16 10.5 F 2 4 4.5 4 4.5
Press. conn. H Rc1/4 1/4-18N T P 1/4-18N T P 1/4-18N T P 1/4-18N T P
TABLE 1
CONNECTION DIAGRAM
+ −/CK− CK+
75
E
Oval frange screw 7/16-20UNF SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 M10 SCREW DEPTH15 M10 SCREW DEPTH15 7/16-20UNF SCREW DEPTH15
20
NOTE2) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). NOTE3) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H,M,T"
10
φ81
70
TABLE 2
Authorities ATEX Intrinsic safety Ex II 1 G Ex ia IIC T5 Tamb = –40°C to +50°C Ex ia IIC T4 Tamb = –40°C to +70°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Factory Mutual Class I II III Div.1 Groups A, B, C, D, E, F G , T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P ,M,1,2,3 Q,S,N,4,5,6 E,F ,G,H,K − 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C CSA Authorities ATEX Flameproof Ex II 2 GD Ex d IIC T6 IP66/67 T85°C Tamb = −40°C to +65°C Ex d IIC T5 IP66/67 T100°C Tamb = −40°C to +85°C Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F G , T6 Type 4X Tamb max = +60°C Class I Div.1 Groups C, D Class II Div.1 Groups E, F G , Class III Div.1 Note) “Seal Not Required” enclosure is allowed. TIIS Ex do IIB+H2 T4 Tamb max = +60°C Maximum process temp. = +120°C Ex d IIC T5 IP66/67 Tamb = −40°C to +85°C Ex d IIC T6 IP66/67 Tamb = −40°C to +65°C Ex d IIB+H2 T6 Tamb = −40°C to +60°C Type n Nonincendive Ex II 3 GD EEx nL IIC T5 Tamb = −40°C to +50°C EEx nL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=25.18nF Li=0.694mH , Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH , EEx nAL IIC T5 Tamb = −40°C to +50°C EEx nAL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W Factory Mutual (pending) Class I II III Div.2 Groups A, B, C, D, F G , T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P ,M,1,2,3 Q,S,N,4,5,6 E,F ,G,H,K − CSA 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C
Factory Mutual
Entity Parameters: Vmax=28V, Imax=94.3mA, Pi=0.66W, Ci=35.98nF Li=0.694mH , CSA Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F G , Class III Div.1 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Imax=94.3mA, Ci=25nF (Without Arrester), Ci=36nF (With Arrester), Li=0.6mH (Without analog meter), Li=0.7mH (With analog meter) Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=38.4nF Li=0.694mH , Ex ia IIC T4 Tamb = –40°C to +70°C Ex ia IIC T5 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Ex ia IIC T4 Ex d IIB+H2 T6 / Ex ia IIC T4 Model code 9th digit A,B,C,D,J L,P ,M,1,2,3 Q,S,N,4,5,6 E,F ,G,H,K − 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C
IECEx Scheme
NEPSI
Authorities ATEX
TIIS
IECEx Scheme
NEPSI
Entity Parameters: Ui=42.4V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH ,
Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F G , Class III Div.2 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Ci=25.18nF (Without Arrester), Ci=35.98nF (With Arrester), Li=0.694mH
11
FKC...5
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.
International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice.
Printed in Japan