0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX6-136H

EDSX6-136H

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX6-136H - REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX6-136H 数据手册
REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER DATA SHEET The FCX–AIII differential pressure transmitter accurately measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. Totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. FKD...5 FEATURES 1. High accuracy 0.2% accuracy for all calibrated spans is a standard feature for all DP models covering 0.32kPa {3.2mbar} range to 500kPa {5bar} high differential pressure range. 0.1% accuracy is available as option. Fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART® bilingual communications protocol FCX–AIII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–AIII. 4. Application flexibility Various options that render the FCX–AIII suitable for almost any process applications include: – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing – Wide selection of materials – High temperature, high vacuum seals 5. Programmable output Linearization Function In addition to Linear and Square Root, output signal can be freely programmable. (Up to 14 compensated points at approximation.) 6. Burnout current flexibility (Under Scale: 3.2 to 4.0mA, Over Scale: 20.0 to 22.5mA) B urnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Static pressure, span, and range limit: Type F KD FKD FKD 3 5 6 Static pressure Span limit [kPa] (m bar} Min. Max. 32 { 320 } 130 { 1300 } 500 { 5000} Range limit [kPa] {m bar} +/− 32 {+/− 320} +/− 130 {+/− 1300} +/− 500 {+/− 5000} } Up to flange rating 0.32 { 3.2 } 1.3 { 13 } 5 { 50 } Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower limit of static pressure (vacuum limit), Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: Atmospheric pressure – The maximum span of each sensor can be converted to different units using factors as below. 1MPa =103kPa=10bar=10.19716kgf/cm2 =145.0377psi 1kPa=10mbar=101.976mmH2O=4.01463H2O Overrange limit: To maximum static pressure limit Output signal: 4 to 20mA DC (linear or square root) with digital signal superimposed on the 4 to 20mA signal Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. EDSX6-136h Date Aug. 10, 2011 FKD...5 Load limitations: see figure below [Ω] 2000 Load resistance 1474Ω R= E-10.5 (Imax+0.9)x10-3 577Ω Operating area 24V 10 16.35 10.5V Power voltage (DC) (1) Process: Fill fluid Fluorinated oil Silicone oil Code in the 13th digit of “Code symbols” W, A and D H J Y and G S 45V 50 E[ V ] T K Process temperature −20 to 120°C −15 to 250°C 20 to 300°C −40 to 180°C 2.7kPa abs −15 to 250°C {20mmHg 20 to 300°C abs} 0.13kPa abs −15 to 200°C {1mmHg abs} or more Atmospheric pressure Lower limit of static press. 1500 1000 500 250 0 Note: For communication with HHC required. (Model: FXW), min. of 250 is Hazardous locations: TABLE 2 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. Damping: Adjustable from HHC or local configurator unit with LCD display. The time constant is adjustable between 0.06 to 32 seconds. Zero elevation/suppression: −100% to +100% of URL Normal/reverse action: Selectable from HHC(1) Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.0mA to 22.5mA from HHC(1) “Output Underscale”: Adjustable within the range 3.2mA to 4.0mA from HHC(1) 3.2 4 20 22.5 [mA] Over scale Burnout Normal operating range Under scale Probable under range Burnout Probable over range Storage: −40 to +90°C Humidity limit: 0 to 100% RH Communication: W ith HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following items can be remotely displayed or configured. Note: HHC’s version must be higher than 7.0 (or FXW 1− 4), for FCX–AIII. Local configurator with LCD display (option): Local confi gurator with 3 push button and LCD display can support following items. Items By communication By local configurator with FXW (with 3 push button) Display Tag No. Model No. Serial No. & Software Version Engineering unit Range limit Measuring range Damping Output mode Burnout direction Calibration Output adjust Data Self diagnoses Printer (In case of FXW with printer option) External switch lock Transmitter display Linearize Rerange Saturate current Write protect History – Calibration history – Ambient temperature history Linear Square root v v v v v v v v v v v — v v v v v v v v v v v Set v v — v — v v v v v v v — — — v v v v v v v — Display v v v v v v v v v v v — v v — v v — v v v v v Set v v — v — v v v v v v v — — — v v — v v v v — Output limits conforming to NAMUR NE43 by order. Loop-check output: Transmitter can be configured to provide constant signal 3.2mA through 22.5mA by HHC(1). Temperature limit: Ambient: −40 to + 85°C (−20 to + 80°C for LCD indicator) (−40 to + 60°C for arrester option) (−10 to + 60°C for fluorinated oil fill transmitter) (−10 to + 85°C for silicone oil “H”, “S”, “K”) *) (+ 20 to + 85°C for silicone oil “J”, “T”) *) *) In case of capillary length is more than 7m, max temperature is +55°C. For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. Programmable output linearization function: Output signal can be characterized with “14 points linear approximation function” from HHC(1). EMC Conformity: EN61326-1: 2006 (Note) (1) HHC: Hand Held Communicator 2 Performance specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode. Physical specifications Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. Process connections: JIS, ANSI, or DIN raised face flanges. JIS: 1 0K80A, 10K100A, 30K80A, or 30K100A ANSI: 150LB 3", 150LB 4", 300LB 3", or 300LB 4" DIN: PN40 DN80 or PN16 DN100 See OUTLINE DIAGRAM for detailed dimensions. Diaphragm extension: 0, 50, 100, 150, or 200mm as specified. (See model code. Extended diaphragm is available only with 316L stainless steel or Hastelloy-C diaphragm) Process-wetted parts material: Diaphragm: 316L stainless steel, Hastelloy-C, Monel, Tantalum, Titanium or Zirconium Flange face: 316 stainless steel, HastelloyC lining Monel lining, or Tantalum lining Extension: 316 stainless steel or HastelloyC Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with polyester coating (standard), or 316 stainless steel (ASTM CF8M), as specified. Capillary: In case of 11th code “D, E, F, L, M, N, P“, PE armored stainless steel. In case of 13th code “Q, R, S, T, V, W, X“, stainless steel armored stainless steel. Mounting flange: 304 stainless steel or carbon steel Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting Mass {weight}: T ransmitter approximately 12 to 31kg without options. Add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option 1.5kg per 50mm extension of diaphragm Accuracy rating: ( including linearity, hysteresis, and repeatability) (Standard) For spans greater than 1/10 of URL: 0.2% of span For spans below 1/10 of URL: 0.1  URL ± 0.1+0.1 % of span Span (Option) (Code; 21th digit H,K) For spans greater than 1/10 of URL: 0.1% of span For spans below 1/10 of URL: 0.1  URL ± 0.05+0.05 % of span Span Stability: ±0.2% of upper range limit (URL) for 10 years. Temperature effect (*): Effects per 28°C change between the limits of −40°C and +85°C (Standard) Zero shift: ±0.35% of URL Total effect: ±0.5% of URL (Option) (Code; 21th digit J,K) Zero shift: ±0.3% of URL Total effect: ±0.4% of URL ( ( ) ) Note: * Excluding effect by temperature difference between the seals. Static pressure effect: Zero shift; 0.2% of URL / 1MPa Span shift: −0.2% of calibrated span / 1MPa Overrange effect: Zero shift; 0.1% of URL for flange rating pressure Supply voltage effect: Less than 0.005% of calibrated span per 1V Update rate: 60 msec Step response: (without electrical damping) Range code “3” “5” “6” Time constant (at 23°C) 2 s 0.12 s 1.7 s 1.7 s Dead time Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100M at 500V DC. Internal resistance for external field indicator: 12 or less 3 FKD...5 [kPa abs] {mbar abs} Silicone (Code Y,G) Silicone (Code S) Silicone (Code T) 101 {1010} Operating pressure 53.3 {533} Operating area [kPa abs] {mbar abs} Sealing liquid:Silicone (Code K) 101 {1010} Operating pressure Operating area 13.3 {133} Non-operating area 2.7 {27} −40 −15 20 60 85 120 180 Process temperature [°C] 230 250 300 0.27 {2.7} 0.13 {1.3} −15 100 Process temperature [°C] 200 Fig. 1 Relation between process temperature and operating pressure Fig. 2 Relation between process temperature and operating pressure Optional features Indicator: A plug-in analog indicator (2.5% accuracy). An optional 5-digit LCD meter with engineering unit is also available. Local configurator with LCD display: An optional 5 digits LCD meter with 3 push buttons can support items as using communication with FXW. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: Oil-free procedures as above. Includes fluorinated oil for fill. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. Vacuum service: Special silicone oil and filling procedure are applied. See Fig. 1, Fig. 2. Optional tag plate: An extra stainless steel tag for customer tag data is wired to the transmitter. Coating of cell: Cell s surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive. ACCESSORIES Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS 8-47) 4 CODE SYMBOLS 12345678 9 10 11 12 13 14 15 21 Digit 4 Description G1/2 T type 1/2-14NPT T type Pg 13.5 T type M20 × 1.5 T type G1/2 L type 1/2-14NPT L type Pg 13.5 L type M20 × 1.5 L type Mounting flange Flange size and rating 304 stainless JIS 10K 80A steel JIS 10K 100A JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN16/40 DN80 DIN PN16 DN100 JIS 20K 80A ANSI/JPI 600LB 3B Carbon steel JIS 10K 80A JIS 10K 100A JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN16/40 DN80 DIN PN16 DN100 316 stainless JIS 10K 80A steel ANSI/JPI 150LB 3B ANSI/JPI 150LB 4B ANSI/JPI 300LB 3B ANSI/JPI 300LB 4B ANSI/JPI 600LB 3B None 3 inch wafer (wafer type) 4 inch wafer 0.32.... 32 {3.2..... 320} 1.3...... 130 {13...... 1300} 5......... 500 {50...... 5000} Flange face Diaph. extension [mm] Diaphragm 316 stainless 0 316L stainless steel 50 steel 100 (*2) 150 200 Hastelloy-C 0 Hastelloy-C 316 stainless steel 0 316L stainless +Au coating 316 stainless steel 0 Hastelloy-C Monel 0 Monel Tantalum 0 Tantalum Titanium 0 Titanium (*3) Zirconium 0 Zirconium Note FKD 5 0 Digit No. of code 5 6 7 8 S T V W 5 0 1 2 3 4 5 6 7 8 9 M R A B C D E F G H J K S T U V W X P Q Note 1 3 5 6 6 7 Note 2 V A B C D H J W M T P R 5 Note 3 8 Note 1: (*1) Note 2: (*2) Note 3: (*3) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance. Available for 5th digit code "1", "3", "5", "7", "B", "D", "F", "H", "K", "Q", "U", "W", when 13th digit code "S", "T", "K". Available for 6th code "5", "6" and 5th code "0", "2", "4", "6", "8", "A", "C", "E", "G", "J", "P", "M", "R", "S", "T", "W". 5 FKD...5 12345678 9 10 11 12 13 14 15 21 Description Digit 9 Indicator Arrester None None Analog, 0 to 100% linear scale None Analog, 0 to 100% sq. root scale (*7) None Analog, custom scale None Analog, double scale (linear and sq. root) None None Yes Analog, 0 to 100% linear scale Yes Analog, 0 to 100% sq. root scale (*7) Yes Analog, custom scale Yes Analog, double scale (linear and sq. root) Yes Digital, 0 to 100% linear scale None Digital, custom scale None Digital, 0 to 100% square root scale None Digital, 0 to 100% linear scale Yes Digital, custom scale Yes Digital, 0 to 100% square root scale Yes Digital, 0 to 100% linear scale (Local configurator unit with LCD display) None Digital, custom scale (Local configurator unit with LCD display) None Digital, 0 to 100% square root scale (Local configurator unit with LCD display) None Digital, 0 to 100% linear scale (Local configurator unit with LCD display) Yes Digital, custom scale (Local configurator unit with LCD display) Yes Digital, 0 to 100% square root scale (Local configurator unit with LCD display) Yes 10 None (for ordinary locations) TIIS, Flameproof (Cable gland seal) (*11) TIIS, Intrinsic safety FM, Flameproof (or explosionproof) (*14) FM, Intrinsic safety and nonincentive FM Combined of flameproof and intrinsic safety (*14) ATEX Flameproof (*13) ATEX Intrinsic safety ATEX Type n ATEX Combined of flameproof and intrinsic safety (*13) IECEx Scheme, Flameproof (*13) IECEx Scheme, Intrinsic safety CSA, Flameproof (or explosionproof) (*14) CSA, Intrinsic safety and nonincentive NEPSI, Flameproof (or exprosionproof) NEPSI, Intrinsic safety NEPSI, Combined of flameproof and intrinsic safety 11 Capillary Mounting bracket armor of capilary 1.5 m 304 Stainless steel PE 3 304 Stainless steel PE 5 304 Stainless steel PE 6 304 Stainless steel PE 7 304 Stainless steel PE 8 304 Stainless steel PE 10 304 Stainless steel PE 1.5 304 Stainless steel Stainless steel 3 304 Stainless steel Stainless steel 5 304 Stainless steel Stainless steel 6 304 Stainless steel Stainless steel 7 304 Stainless steel Stainless steel 8 304 Stainless steel Stainless steel 10 304 Stainless steel Stainless steel 12 Extra SS tag plate Stainless steel elec. housing None None Yes None None (*6) None Yes None None Yes (*8) Yes Yes Note 4: (*4) Note 5: Note 6: Note 7: Note 8: (*5) (*6) (*7) (*8) Note FKD 5 0 Digit No. of code Note 7 Note 7 A B C D J E F G H K L P M Q S N 1 2 3 4 5 6 Note 11 Note 14 Note 14 Note 13 Note 13 Note 13 Note 14 A C G D H V X K P M R T E J F S U (*4) (*4) (*4) (*4) (*4) (*4) (*4) (*5) (*5) (*5) (*5) (*5) (*5) (*5) Coating of cell None None Yes Yes Yes Yes Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 4 Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 D E L F M N P Q R S T V W X Note 6 Note 8 Note 8 Y B M N P Q Available for 13th digit code "Y, W, G, A, D". Inquire about in case of 13th other code. Available for all 13th digit code. Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select "Yes". In case of squre root output mode, squre root scale is not available. Not available for 10th digit code "C". 6 12345678 9 10 11 12 13 14 15 21 Note Description Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code "V", "W", "A", "B", "C" and "D") Chlorine service Fluorinated oil (7th digit code "H", "T") High temp. 250°C Silicone oil 7th digit code "V", "W", "A", "B", "C", High temp. 300°C Silicone oil "D", "H", "F", "G", "K", and "L" (*9) High temp. and vacuum (250°C) Silicone oil 7th digit code "V", "W", "A", "B", "C", Note 9 High temp. and vacuum (300°C) Silicone oil and "D" High temp. and high vacuum Silicone oil 14 None Yes (Available for 5th digit code "0", "2", "4", "6", "8", "A", "C", "E", "G", "J", "P", "M", "R", "S", "T", "V", "X" and 7th digit code "V", "W", "J". Not available for the 13th digit code "H", "J".) (*10) Note 10 21 High accuracy type Instruction manual attached Low temperature effect type Instruction manual attached H+J Instruction manual attached Instruction manual unattached High accuracy type Instruction manual unattached Low temperature effect type Instruction manual unattached T+U Instruction manual unattached Note 9: (*9) Treatment; Standard Note 10: (*10) If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. Note 11: (*11) Available for 4th digit code "S". Note 13: (*13) Available for 4th digit code "6", "8", "T", "W". Note 14: (*14) Available for 4th digit code "6", "T". Digit 13 FKD 5 0 Digit No. of code Y W G A D H J S T K Y C H J K L T U V 7 FKD...5 ORDERING INFORMATION When ordering this instrument, specify: 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Hold / Overscale / Underscale Unless otherwise specified, output hold function is supplied. 4. Output mode (linear or square root output) Unless otherwise specified, output mode is linear. 5. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S ,2 ,5 on 9th digit). 6. Tag No. (up to 14 alphanumerical characters), if required. 8 OUTLINE DIAGRAM (Unit:mm) MTG. PIPE JIS 50A (2B) 10 ZERO ADJ. SCREW IN CASE OF 4TH DIGIT CODE "S,V,W" IN CASE OF 4TH DIGIT CODE "T" 8 38 U-BOLT M8 57 37 "B" CONDUIT CONN. 195 (21) (11) WITH ANALOG IND. N HOLES h DIA 4 HOLES 9 DIA. INNER OF GASKET WITH DIGITAL IND. φH±1 φ81 103 103 P φD φE φF φG FLANGE 242 t 41 126 43 EARTH TERMINAL 20 L φ15 M K 2-M8X12 S J SEE TABLE1 L.P. 4th digit of the code symbols S T V W Conduit conn. J K M G 1/2 18 2 1/2-14NPT 16 4 Pg13.5 10.5 4.5 M20×1.5 16 4 7th digit of the code symbols V, W, J, H, M, T, P, R A B C D L 0 50 100 150 200 MASS.APPROX(kg) 12.7∼18.2 13.7∼29.2 14.2∼29.7 14.7∼30.2 15.2∼30.7 62 70 120 INNER OF GASKET 221 H.P. 2-M6 SCREW DEPTH 9 DETAIL "B" (CONDUIT CONN.) 5th digit of the code symbols 0, A, S M 2, C 1, B 3, D 4, E, T 6, G, V R, X 5, F, U 7, H, W 8, J 9, K φD 185 200 210 210 240 191 210 210 229 254 200 220 φF CorrosionStandard resistant materials materials specification specification φE Note 1 Note 2 126 134 150 126 134 160 126 134 170 151 158 175 151 158 195 126 134 152.5 126 134 168 126 134 168 151 158 190.5 151 158 200 126 134 160 180 151 158 φG φH±1 100 100 100 103 103 100 100 100 103 103 100 103 73 73 73 96 96 73 73 73 96 96 73 96 t 38 42 48 38 52 44 49 52 44 52 44 40 P 116 116 116 141 141 116 116 116 141 141 116 141 N-φh 8-19 8-23 8-23 8-19 8-25 4-20 8-23 8-23 8-20 8-23 8-18 8-18 FLANGE JIS-10K-80A JIS-20K-80A JIS-30K-80A JIS-10K-100A JIS-30K-100A ANSI 150LB 3B ANSI 300LB 3B ANSI 600LB 3B ANSI 150LB 4B ANSI 300LB 4B DIN PN40 DN80 DIN PN16 DN100 φG φF 20 <WAFER TYPE> 11th digit of the code symbols D, Q E, R L, S F, T M, V N, W P, X S(m) 1.5 3 5 6 7 8 10 80A, 3B 100A, 4B Q 116 141 Note1) In case of the 7th digit of type code is V, A, B, C, D, J or W. Note2) In case of the 7th digit of type code is H, M, T, P or R. OPTION PARTS FOR FLAMEPROOF OF TIIS (JAPAN) 10th digit code C (Cable gland type) NOTE1) G1/2 φ33.5 DETAIL C φ13 CONNECTION DIAGRAM + −/CK− CK+ 75 106 20 "C" CONDUIT CONN. G1/2 CABLE GLAND NOTE1) IN CASE OF 10TH CODE “C”φ11 CABLE IS SUITBLE. , 17 19 Q TABLE 1 φ E φ81 9 FKD...5 IN CASE OF 4TH DIGIT CODE "5,7,8" MTG. PIPE JIS 50A (2B) 10 IN CASE OF 4TH DIGIT CODE "6" EARTH TERMINAL (21) (11) WITH ANALOG IND. WITH DIGITAL IND. 8 ZERO ADJ. SCREW 100 38 U-BOLT M8 57 37 208 "B" CONDUIT CONN. 100 N HOLES h DIA 4 HOLES 9 DIA. INNER OF GASKET φH±1 φD φE φF φG P FLANGE 20 L t 242 127 20 DETAIL "B" (CONDUIT CONN.) φ15 M 248 J SEE TABLE1 2-M8X12 S K L.P. 4th digit of the code symbols 5 6 7 8 Conduit conn. J K M G 1/2 18 2 1/2-14NPT 16 4 Pg13.5 10.5 4.5 M20×1.5 16 4 7th digit of the code symbols V, W, J, H, M, T, P, R A B C D L 0 50 100 150 200 MASS.APPROX(kg) 12.7∼18.2 13.7∼29.2 14.2∼29.7 14.7∼30.2 15.2∼30.7 62 70 120 φ E H.P. INNER OF GASKET 2-M6 SCREW DEPTH 9 5th digit of the code symbols 0, A, S M 2, C 1, B 3, D 4, E, T 6, G, V R, X 5, F, U 7, H, W 8, J 9, K φD 185 200 210 210 240 191 210 210 229 254 200 220 φF CorrosionStandard resistant materials materials specification specification φE Note 1 Note 2 126 134 150 126 134 160 126 134 170 151 158 175 151 158 195 126 134 152.5 126 134 168 126 134 168 151 158 190.5 151 158 200 126 134 160 180 151 158 φG φH±1 100 100 100 103 103 100 100 100 103 103 100 103 73 73 73 96 96 73 73 73 96 96 73 96 t 38 42 48 38 52 44 49 52 44 52 44 40 P 116 116 116 141 141 116 116 116 141 141 116 141 N-φh 8-19 8-23 8-23 8-19 8-25 4-20 8-23 8-23 8-20 8-23 8-18 8-18 FLANGE JIS-10K-80A JIS-20K-80A JIS-30K-80A JIS-10K-100A JIS-30K-100A ANSI 150LB 3B ANSI 300LB 3B ANSI 600LB 3B ANSI 150LB 4B ANSI 300LB 4B DIN PN40 DN80 DIN PN16 DN100 φG φF 20 <WAFER TYPE> 11th digit of the code symbols D, Q E, R L, S F, T M, V N, W P, X S(m) 1.5 3 5 6 7 8 10 80A, 3B 100A, 4B Q 116 141 Note1) In case of the 7th digit of type code is V, A, B, C, D, J or W. Note2) In case of the 7th digit of type code is H, M, T, P or R. CONNECTION DIAGRAM + −/CK− CK+ 20 10 75 Q TABLE 1 φ81 TABLE 2 Authorities ATEX Intrinsic safety Ex II 1 G Ex ia IIC T5 Tamb = –40°C to +50°C Ex ia IIC T4 Tamb = –40°C to +70°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Factory Mutual Class I II III Div.1 Groups A, B, C, D, E, F G , T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P ,M,1,2,3 Q,S,N,4,5,6 E,F ,G,H,K − 13th digit Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C CSA Authorities ATEX Flameproof Ex II 2 GD Ex d IIC T6 IP66/67 T85°C Tamb = −40°C to +65°C Ex d IIC T5 IP66/67 T100°C Tamb = −40°C to +85°C Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F G , T6 Type 4X Tamb max = +60°C Class I Div.1 Groups C, D Class II Div.1 Groups E, F G , Class III Div.1 Note) “Seal Not Required” enclosure is allowed. TIIS Ex do IIB+H2 T4 Tamb max = +60°C Maximum process temp. = +120°C Ex d IIC T5 IP66/67 Tamb = −40°C to +85°C Ex d IIC T6 IP66/67 Tamb = −40°C to +65°C Ex d IIB+H2 T6 Tamb = −40°C to +60°C Factory Mutual Entity Parameters: Vmax=28V, Imax=94.3mA, Pi=0.66W, Ci=35.98nF Li=0.694mH , CSA Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F G , Class III Div.1 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Imax=94.3mA, Ci=25nF (Without Arrester), Ci=36nF (With Arrester),Li=0.6mH (Without analog meter), Li=0.7mH (With analog meter) Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=38.4nF Li=0.694mH , Ex ia IIC T4 Tamb = –40°C to +70°C Ex ia IIC T5 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Ex ia IIC T4 Ex d IIB+H2 T6 / Ex ia IIC T4 Model code 9th digit A,B,C,D,J L,P ,M,1,2,3 Q,S,N,4,5,6 E,F ,G,H,K − 13th digit Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C IECEx Scheme NEPSI Authorities ATEX Type n Nonincendive Ex II 3 GD EEx nL IIC T5 Tamb = −40°C to +50°C EEx nL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=25.18nF Li=0.694mH , Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH , EEx nAL IIC T5 Tamb = −40°C to +50°C EEx nAL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W TIIS IECEx Scheme NEPSI Factory Mutual (pending) Class I II III Div.2 Groups A, B, C, D, F G , T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P ,M,1,2,3 Q,S,N,4,5,6 E,F ,G,H,K − 13th digit Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K Y,G,H,J,S,T,K W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C Entity Parameters: Ui=42.4V, Ii=113mA, Pi=1W, Ci=35.98nF Li=0.694mH , CSA Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F G , Class III Div.2 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Ci=25.18nF (Without Arrester), Ci=35.98nF (With Arrester), Li=0.694mH 11 FKD...5 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan
EDSX6-136H 价格&库存

很抱歉,暂时无法提供与“EDSX6-136H”相匹配的价格&库存,您可以联系我们找货

免费人工找货