    EDSX6-139H - PORTABLE TYPE ULTRASONIC FLOWMETER (PORTAFLOW-C) - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX6-139H 数据手册
PORTABLE TYPE DATA SHEET ULTRASONIC FLOWMETER (PORTAFLOW-C) FSC, FSD P ORTAFLOW-C is a portable type ultrasonic flowmeter utilizing the transit time measuring method, using a clampon type detector. It is a compact and lightweight instrument incorporating the latest electronics and digital signal processing technologies, realizing high performance and easy operation. FEATURES 1. Compact and lightweight The adoption of the latest electronics and digital signal processing technologies has reduced the size and weight of the flow transmitter by 30% and 30%, respectively, in comparison with the Fuji conventional portable flowmeter (Model FSC). (in comparison to our existing model) 2. Battery operation The flowmeter is designed for 12 hours of continuous operation via built-in battery which is rechargeable in 3 hours with the exclusive power adapter. 3. Full variety of detectors The flowmeter is suitable for various types of detectors applicable for small to large diameter pipe (pipe inner diameter φ13 to φ6000mm) and low to high temperature (−40 to +200°C). 4. High accuracy and high-speed response The flowmeter is designed for high accuracy (±1.0%). Response time is within 1 second. 5. Improved anti-bubble characteristic Anti-bubble characteristic is greatly improved by digital signal processing. 6. Excellent performance and easy operation Large graphic LCD that is outside but easy to read. Minimum number of function keys are used for page selection, allowing easy setting. While battery is working, the flowmeter is water resistant and tolerates exposure to rain. 7. Large capacity storage by SD memory card Measured data is periodically stored in SD memory card. For example, in the case of 256MB (option), it can be saved about 1 year measurement date(In case of saving period 30 seconds, 14 kinds of saved data). Available up to 8MB. 8. Serial communication Use of a USB port allows easy connection to a personal computer. Measured date collection panel and Loader software for PC (standard) which is available for display and change of parameter (site setting) are prepared. 9. Heat quantity (calorie) measurement Heat quantity (calorie) may be measured by temperature input, making energy management easy for cooling and heating. Flow transmitter (FSC) Detector for transit time(FSD) Detector for high-temperature(FSD) 10. Graphic printer connection (option) Easy recording with the Integral type printer. 11. Flow velocity profile measurement (option) Flow profile may be observed in real time. SPECIFICATIONS Measuring objects Measurement fluid: Uniform liquid in which ultrasonic waves can propagate. Turbidity of fluid: 10000 mg/L or less State of fluid: Well-developed turbulent or laminar flow in a filled pipe. Fluid temperature: −40 to +200°C Measuring range: 0···±0.3 to ±32m/s Piping conditions Applicable piping material: Select from carbon steel, stainless steel, cast iron, PVC, FRP, copper, aluminum, acrylic or material of known sound velocity. Pipe size: Flow rate measurement φ13 to φ6000mm Flow velocity profile measurement φ40 to φ1000mm EDSX6-139h Date Jul. 22, 2011 FSC, FSD Lining material: Select from no lining, tar epoxy, mortar, rubber, Teflon, pyrex glass or material of known sound velocity. Note) No gap allowed between the lining and the pipe. Straight pipe length: 10D or more upstream and 5D or more downstream (D: internal pipe diameter) Refer to Japan Electric Measuring Instruments Manufactures’ Association’s standard JEMIS-032 for details. Analog output signals: 4 to 20mA DC, one point (load resistance, 600Ω or less) Instantaneous velocity, instantaneous flow rate or heat quantity (calorie) after scaling. Analog input signal: 4 to 20mA DC, one point (input resistance, 200Ω or Total less) 4 to 20mA DC, one point (in- 2 points put resistance, 200Ω or less) or 1 to 5V DC, one point Used to input temperature for heat quantity measurement, etc. SD memory card: Used for data logger function and recording screen data. Available up to 8GB (Option256MB) Compliant media • SD memory card: speed class 2, 4, 6 • SDHC memory card: speed class 4, 6 Format • FAT16: 64MB to 2GB • FAT32: 4GB, 8GB Otherwise, reading and saving are impossible. File format • Date logger: CSV file • Screen date: Bit map file Serial communication: USB port (device* compatible): Mini B receptacle Connectable number of Mini B receptacles: 1 unit Transmission distance: 3m max. Transmission speed: 500kbps Data: Instantaneous velocity, instantaneous flow rate, total value, heat quantity (calorie) value, error information, logger data, etc. * Device: Connected plug from PC Printer (option): To be mounted on top of transmitter unit Thermal line dot printing Note) When the Chinese display is selected, printing is made in kanji characters. Ambient temperature: −10 to +55°C (Without printer) −10 to +45°C (With printer) Ambient humidity: 90%RH or less Type of enclosure: IP64 (Without printer) Enclosure case: Plastic case Outer dimensions: H210 × W120 × D65mm (Without printer) H320 × W120 × D65mm (With printer) Weight: 1.0kg (Without printer) 1.2kg (With printer) Performance specifications Accuracy rating: Pipe inner diameter φ13 to φ50mm φ50 to φ300mm φ300 to φ6000mm Flow velocity range 2 to 32m/s 0 to 2m/s 2 to 32m/s 0 to 2m/s 1 to 32m/s 0 to 1m/s Accuracy ±1.5% of rate ±0.03m/s ±1.0% of rate ±0.02m/s ±1.0% of rate ±0.01m/s Note) Reference conditions are based on JEMIS-032. Flow transmitter (Type: FSC) Power supply: Built-in battery or AC power adapter Built-in battery: Exclusive lithium button battery (5000m Ah) Continuous operation time, approx. 12 hours (without printer, back light OFF, output current not used and at normal ambient temperature (20°C)) Recharging time, approx. 3 hours (power adapter used) Recharging temperature range: 0 to +40°C Power consumption: Min. 3W and Max. 16W The consumption varies depending on the use conditions. Power adapter: Exclusive power adapter 90V to 264V AC (50/60Hz), 70VA or less. LCD: Semi-transmissive color graphic display 240 × 320 (with back light) Measurement value (instantaneous flow rate, integrated flow rate) and various settings are displayed. Excellent visibility even outdoors in direct sunlight. LED display: Status display when using AC power adapter. DC IN (green): Power supply status CHARGE (red): Battery charging underway Operation keypad: 11 buttons (ON, OFF, ENT, ESC, MENU,  ,  ,  ,  , LIGHT, PRINT) Power failure backup: Measurement value is backed up by nonvolatile memory. Clock backup with lithium battery (effective term, 10 years or more) Response time: 1 second Various functions Display language: Selectable from Japanese, English, German, French, Spanish or Chinese (switchable by key operation). Clock display function: Time (year, month, day, hour, minute) display (configurable) Monthly error: about 1 minutes at normal temperature (20°C). 2 Instantaneous value display function: Instantaneous velocity, instantaneous flow rate display (The flow in reverse direction is displayed with minus “−.”) Numeric value: 10 digits (decimal point equals 1 digit) Unit: Metric/English system selectable Metric system Velocity: m/s Flow rate: L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s, m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d, MBBL/d English system Velocity: ft/s Flow rate: gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d, ft3/s, ft3/min, ft3/h, ft3/d, kft3/d, Mft3/d, BBL/s, BBL/min, BBL/h, BBL/ d, kBBL/d, MBBL/d Total value display function: Display of forward or reverse total (reverse is displayed as minus) Numeric value: 10 digits (decimal point is corresponding to 1 digit) Unit: Metric/English system selectable Metric system Flow rate total: mL, L, m3, km3, Mm3, mBBL, BBL, kBBL English system Flow rate total: gal, kgal, ft3, kft3, Mft3, mBBL, BBL, kBBL, ACRE-ft Consumed heat quantity (calorie) display function: Display of consumed heating medium Metric system Heat flow: MJ/h, GJ/h Total heat quantity: MJ, GJ English system Heat flow: MJ/h, GJ/h, BTU/h, kBTU/h, MBTU/h, kWh, MWh Total heat quantity: MJ, GJ, BTU, kBTU, MBTU, kW, MWh J : Joule BTU : British thermal unit W : Watt Computation function of consumed heat quantity (calorie): This function calculates the heat quantity received and sent with liquid (water) in cooling and heating. Consumed heat quantity q = K · Q · (T1–T2) K : heat quantity (calorie) conversion factor (For heating K = 4.123, For cooling = 4.186) Temperature display function: Fluid temperature be displayed by current input from temperature transmitter. Metric system Temperature unit: °C or K English system Temperature unit: F or K Site data storage function: Max. 32 locations (sites) data (pipe size, material, fluid type and etc) can be stored into built-in non-volantile memory. Damping: 0 to 100sec (every 0.1sec) configurable for analog output and velocity/flow rate display Low flow cut: Equivalent to 0 to 5m/s Output setting function: Current output scaling, output type, burnout setting and calibration Serial communication function: Instantaneous velocity, instantaneous flow rate, total value, heat flow, error information, received waveform, analog input, velocity profile data, logger data, etc. may be downloaded to personal computer. Logger function: Instantaneous velocity, instantaneous flow rate, total value, heat flow, error information, received waveform, analog input, velocity profile date can be saved in a SD memory card. Waveform display function: Bi-directional received waveforms may be displayed. Graph display function: Flow rate trend graph may be displayed. Printing function (option): Hard copy output of a screen Periodic printing (type: text, graph) Logger date (type: text, graph) Flow velocity profile measurement (option): Flow velocity profile may be observed in real time using the exclusive detector (option). (Refer to page 5 for details.) Detector (Type: FSD) Type of detector: Kind Small diameter Small type Middle type Large type High temperature Type FSD22 FSD12 FSD41 FSD51 FSD32 Internal pipe diameter (mm) φ13 to φ100 φ50 to φ400 φ200 to φ1200 φ200 to φ6000 φ50 to φ400 Fluid temperature −40 −40 −40 −40 −40 to to to to to 100°C 100°C 80°C 80°C 200°C Converter Temperature sensor T1: Fluid temperature (inlet) Converter Temperature sensor Detector (type : FSD) Mounting method: Mounting on outside of pipe Sensor mounting method: V or Z method Signal cable: Exclusive coaxial cable Standard 5m (included with FSD41, 51 and FSD32) Heat exchanger T2: Fluid temperature (outlet) Heat source Q: Flow rate of the fluid 3 FSC, FSD Method for connection: Flow transmitter side Exclusive connector Detector side Large/middle type: Screw terminal Others: BNC connector Ambient temperature: −20 to +60°C Ambient humidity: Large/middle type sensor: 100%RH or less Others: 90%RH or less Type of enclosure: Large/middle type sensor: IP67 Others: IP52 Material and mounting belt/wire: Kind Type Sensor case Mounting bracket Aluminum alloy Plastic + Plastic Aluminum alloy Plastic + Plastic Plastic SUS304 Plastic −− Aluminum alloy SUS304 + SUS304 Mounting belt /wire Plastic cloth belt Plastic cloth belt Stainless wire Stainless wire Stainless belt MEASURING PRINCIPLE With ultrasonic pulses propagated diagonally between the upstream and downstream sensors, flow rate is measured by detecting the time difference obtained by the flow of fluid. Detector Upstream sensor θ Flow velocity V t1 t2 D Output Flow signal transmitter Downstream sensor MOUNTING OF DETECTOR PZT oscillator Plastic wedge Pipe Lining Small diamFSD22 eter Small type FSD12 Middle type FSD41 Large type FSD51 High temperaFSD32 ture Extension cable (option): Extended when the length of the detector signal cable is not sufficient. Length: 10m, 50m CONFIGURATION DIAGRAM (1) When V method is used for mounting Cable Detector Flow transmitter Cable Detector 4 to 20mA DC (2) When Z method is used for mounting DETECTOR SELECTION GUIDE Type (Name) FSD22 (Small diameter) FSD12 (Small type) FSD41 (Middle type) FSD51 (Large type) Fluid temperature Mounting method [°C] −40 to 100 −40 to 100 V V Z V −40 to 80 Z V −40 to 80 Z V Z *1) 50 150 200 200 250 400 400 1200 3000 6000 *1) Inner diameter of piping ø (mm) 13 25 *2) 13 50 150 200 100 300 400 600 50 100 200 250 300 400 1000 3000 6000 FSD32 (High-temperature) −40 to 200 *1) When FSD12 or FSD32 is mounted using the Z-size method, guide rail (option) is required additionally. *2) For the pipe inner diameter of φ13mm, the sensor mounting dimension may be 0.0mm or less depending on pipe material and thickness. When the sensor mounting dimension is 0.0mm or less,measurement error is about 2 to 5%. It shows pipe thickness of each material that the sensor mounting size is to be 0.0mm, when fixing a pipe. If the fluid is the one other than water, and if the sound velocity of fluid is faster than the one of water, the sensor mounting size is to be 0.0mm or more. Required min. pipe thickness (fluid: water) (Unit: mm) Steel pipe 2.15 or more FRP 3.21 or more Stainless pipe 1.87 or more Ductile cast iron 2.15 or more PVC pipe 3.69 or more PEEK 3.69 or more Copper pipe 3.82 or more PVDF 3.69 or more Cast-iron pipe 2.98 or more Acrylic pipe 2.90 or more Aluminum pipe 1.99 or more Polypropylene 3.69 or more 4 Flow transmitter 4 to 20mA DC FLOW VELOCITY PROFILE DISPLAY FUNCTION (OPTION) Flow velocity profile can be observed in real time using the dedicated detector from the outside. It is specifiable by the code symbol of flow transmitter. Measurement principle • Ultrasonic pulses are transmitted through the fluid flow. Entrained bubbles and microscopic particles within the fluid create frequency phase shifts (Doppler effect.) The resulting doppler shifts are integrated across the inside pipe diameter cross section. The resulting profile curve is a real-time dynamic display of the flow profile within the pipe. Sensor 1 (FSD) APPLICATION Pulse Doppler method is applicable to observe flow velocity profile in real time, display the flow status in the pipe, and decide the appropriate measurement location. Also, it can be used for diagnosis of flow and laboratory test. SPECIFICATIONS Measuring fluid: Uniform liquid in which ultrasonic waves can propagate. Turbidity of fluid: Axisymmetric flow in a filled pipe. Fluid temperature: −40 to +100°C (FSDP2) −40 to +80°C (FSDP1,FSDP0) Air bubble quantity: 0.02 to 15Vol% (Velocity is 1m/s) Pipe size: Small type sensor : φ40 to φ200mm Middle type sensor :φ100 to φ400mm Large type sensor :φ200 to φ1000mm Measurement range: 0 to ±0.3: ±Maximum Velocity (depending on the pipe diameter) Refer to chart, table.1. Note) This function is to observe flow velocity profile, and it may be different from actual flow rate. Air bubbles Reflection Sensor 2 (FSD) Flow velocity Profile 2 Flow velocity Profile 1 Flow Flow velocity Piping wall Center Piping wall The above shows an example when using two sensors. One detector displays the flow velocity profile for a radius. Block diagram (1) Using one sensor Cable Sensor (FSD) Flow Transmitter Power supply DETECTOR FOR FLOW VELOCITY PROFILE MEASUREMENT (TYPE: FSDP) Mounting method: Mounting on outside of existing pipe Ambient temperature: −20 to +80°C Ambient humidity: 100% RH or less Type of enclosure: IP67 (with waterproof BNC connector provided.) Material: Sensor housing: PBT Guide frame: Aluminum alloy Mounting belt: Plastic cloth belt/stainless belt (2) Using two sensors Cable Sensor (FSD) Power supply Flow Transmitter Sensor (FSD) 5 FSC, FSD Table.1 Maximum measurement range of Pulsed Doppler method. When nominal thickness of a stainless pipe of pipe material is Sch20s and the fluid is water, the maximum measurement range varies depending on the outer diameter of pipe, nominal thickness, material, or fluid type. Unit: m/s Diameter FSDP2 FSDP1 FSDP0 40A 6.56 50A 6.52 65A 5.31 80A 4.65 90A 4.12 100A 3.69 7.25 125A 6.08 3.08 150A 5.20 2.63 200A 4.05 7.77 2.04 250A 6.38 3.30 300A 5.41 2.78 350A 4.90 2.51 400A 4.31 2.20 450A 3.80 500A 3.48 550A 3.17 600A 2.91 650A 2.71 700A 2.52 750A 2.35 800A 2.21 850A 2.08 900A 1.97 1000A 1.77 Unit: m3/h FSDP2 FSDP1 FSDP0 33.6 52.7 72.1 86.5 102 118 231 289 147 354 179 474 908 239 1168 604 1428 735 1598 820 1858 951 2118 2358 2618 2879 3096 3357 3618 3879 4140 4400 4902 PC Loader software Equipped as standard • PC/AT compatible machines. (Operation on custom built PCs or shop-brand PCs cannot be guaranteed.) • Major functions: Performs parameter (site setting) display /change of the main unit and collects measured date. Instantaneous velocity, instantaneous flow rate, total value, error information, received waveform, analog input, logger data, etc. may be downloaded in a personal computer. • O/S: Windows2000/XP/Vista* • Memory requirement: 128MB or more • Disk unit: Windows2000/XP/Vista-compatible CD-ROM drive • Hard disk drive capacity: Free space of 64MB or more * Windows Vista: Use it in basic mode. It is not available for Windows Aero. CODE SYMBOL 12345678 9 10 11 FSC S 1 2 0 1 1- 0 Description Standard Basic system Basic system + Printer None Provided (detector to measure flow velocity profile is separately required.) AC power + power cord (125V AC) for Japanese and North American use AC power + power cord (250V AC) for European and Korean use AC power + power cord (250V AC) for Chinese use Modification No. None Provided (256MB) None (Factory-set language: English) Provided/Japanese (Factory-set language: Japanese) Provided/English (Factory-set language: English) Provided/Chinese (Factory-set language: Chinese) A B C 1 0 1 Y J E C (Note1) Instruction manual contained in CD is the standard attached article. (Note2) You can change the language by key operation. 6 (for transit time) 12345678 OPTIONAL ITEMS Description Name 1 2 Battery AC power adapter Specifications Special type Li-ion battery (7.4V, 2500mAh) Arrangement No. ZZP∗TK7N6384P1 FSD 1 2 4 5 3 2 2 1 1 2 0 1 Small type (for φ50 to φ400mm) *1) *2) Small diameter (for φ13 to φ100mm) Middle type (for φ200 to φ1200mm) Large type (for φ200 to φ6000mm) High-temperature (for φ50 to φ400mm) *1) *2) None Provided (Middle/Large type only) Y 1 Special type power adapter and 90 to 264V AC, 50/60Hz · Power connector conversion code ZZP∗TK7N6380C4 3 Power code General use Modification No. Japan, North America:125V AC 2m Europe, Korea: 250V AC 2m China: 250V AC 2m To be mounted on top of converter Thermal serial dot system (8 x 384 dot) Maker: SEIKO I SUPPLY Co. Ltd. Type: TP-211C-1 Specifications: Thermal roll paper Width: 58mm×ø48mm ZZP∗TK7N6621P1 ZZP∗TK7N6608P1 ZZP∗TK7N6609P1 ZZP∗TK4J2634C1 4 Printer Note) *1) Applicable diameter range: V method: φ50 to φ250 (FSD32), φ50 to φ300 (FSD12) Z method: φ150 to φ400 (FSD32, FSD12) Use the optional guide rail, if a pipe that does not allow ultrasonic waves to pass through easily, such as when an old pipe, cast iron pipe or a pipe with mortar lining is used, or the flow or liquid high in turbidity is measured. Employ the Z method for mounting. 5 Printer roll paper ZZP∗TK7N6381P1 6 Silicone grease (for flow velocity profile measurement) 12345678 Maker: Shin-Etsu Chemical Co., Ltd. Type: · For standard use G40M, 100g ZZP∗45231N5 · For high temperature KS62M, 100g ZZP∗TK7P1921C1 Special type signal cable, 5m × 2 · FSD12, 22, 32 (Connector on one side) · FSD41 (Connector on one side) · FSD51 (Connector on one side) ZZP∗TK7N7795C1 ZZP∗TK7N7795C2 ZZP∗TK7N7795C3 ZZP∗TK7N6323P11 7 Signal cable FSD P2 P1 P0 0Y1 Description Small type (φ40 to φ200mm) Middle type (φ100 to φ400mm) Large type (φ200 to φ1000mm) 0 8 9 BNC adapter · BNC adapter (×2) Extension signal cable None Y 1 General use Modification No. Special type coaxial cable with BNC connector ZZP∗TK468664C3 · 10m × 2 ZZP∗TK468664C4 · 50m × 2 ZZP∗TK4J2639C1 10 Analog 6-core cable, 1.5m, with connector input/output cable SCOPE OF DELIVERY Name of unit 1 Basic system Scope of delivery 1) Conversion unit 2) Power adapter and Power connector conversion cord 3) Power cord 4) Analog input/output cord (1.5m) 5) USB cable (1m) 6) Carrying case 7) Strap 8) Special type signal cable (5m × 2) 9) BNC adapter 10) CD-ROM (Instruction manual and Loader software for PC) 1) Printer unit + rolled paper (1 roll) 2) SD memory card (256MB) 3) Bound instruction manual (including a detector) 11 Mounting belt /wire · Small type/small diameter sensor: Plastic cloth belt · Large type sensor: Stainless wire Nominal diameter f200 to f500mm f200 to f1000mm f200 to f2000mm f200 to f3000mm f200 to f6000mm · High-temperature sensor: Stainless steel belt ZZP∗TK7G7979C1 ZZP∗TK7G7980C1 ZZP∗TK7G7980C2 ZZP∗TK7G7980C3 ZZP∗TK7G7980C4 ZZP∗TK7G7980C5 ZZP∗TK7P1943C1 2 Option 12 Guide rail for hightemperature sensor (In mounting by the Z method) ZZP∗TK4J5917C3 · Mounting bracket material: Aluminum alloy+SUS304 · FSD32 Name of unit Scope of delivery 1 Detector for propa- 1) Sensor unit gation time differ- 2) Signal cable (5m) (included with FSD41, 51) ence (FSD) 3) Mounting belt/wire 4) Silicone grease (100g) 2 Detector for flow 1) Detector unit v e l o c i t y p r o f i l e 2) Mounting belt/wire (FSDP) 3) Silicone grease (100g) Note 1) Silicon grease is for filling a gap between a detector and a pipe joint area. It is provided with a detector. Since silicon grease does not become hardened, if you use it in the long term, periodic maintenance is required. (Under the condition of room temperature, semiannual cleaning and refill is recommended.) Note 2) When you order a detector alone, an instruction manual is not provided. Please request, if necessary. 13 Guide rail for · Mounting bracket material: small type Aluminum alloy+plastic detector · FSD12 (In mounting by the Z method) 14 SD memory Maker: Apacer Technology, Inc. card Type: AP-ESD256TPSR Capacity: 256MB 15 USB cable Maker: Sunwa Supply Inc. Type: KU-AMB510 Specifications: Mini USB cable (1.0m) ZZP∗TK4J5917C1 ZZP∗TK7N6386P1 ZZP∗TK7N6622P1 7 FSC, FSD Diagram To connect signal cables for FSD12, FSD22, FSD32, FSDP2, FSDP1, FSDP0 Exclusive use signal cable Printer (option) BNC connector Detector To connect signal cables for FSD41 FSD51 BNC connector Signal cable PORTAFLOW Detector input (the downstream side) Detector input (the upstream side) Detector Flow transmitter BNC adaptor AO analog output 4 to 20mA DC AICH1 analog input 4 to 20mA DC or 1 to 5 V DC AICH2 analog input 4 to 20mA DC AC90 to 264V ON FEED OFF ESC ENT Analog input/output cable Print MENU CHARGE DC IN PC SD SD memory card USB cable To connect PC Power connector Conversion cord Power cord AC power adaptor for use AC adaptor Conditions on straight pipe (D: Nominal diameter of pipe) Type Length of upstream straight pipe Length of downstream straight pipe L ≥ 5D 10D or more L ≥ 10D 90° bend Detector 10D or more L ≥ 10D L ≥ 50D Tee 10D or more 0.5D or more L ≥ 30D D L ≥ 5D Diffuser 1.5D or more L ≥ 10D Contraction pipe L ≥ 50D L ≥ 30D Valve Flow controlled upstream Isolation valve Check valve L ≥ 50D Pump P L ≥ 10D Flow controlled downstream Note) Source: Japan Electric Measuring Instruments Manufacturers' Association (JEMIS-032) 8 OUTLINE DIAGRAM (Unit:mm) Flow transmitter 120±1.8 65±1.8 2-M4, Depth5 (both sides) PORTAFLOW Sensor (downstream) DOWNSTREAM 210±2.5 UPSTREAM SENSOR Sensor (upstream) AI/AO ON FEED OFF ESC ENT DC12V Analog input/output Print MENU CHARGE DC IN DC power input Power switch SD memory card slot USB port Weight : Approx. 1.0kg 9 FSC, FSD OUTLINE DIAGRAM (Unit:mm) Flow transmitter (with printer) 120±1.8 65±1.8 Printer 2-M4, Depth5 (both sides) Approx. 320±4.5 PORTAFLOW Sensor (downstream) DOWNSTREAM UPSTREAM SENSOR Sensor (upstream) AI/AO ON FEED OFF ESC ENT DC12V Analog input/output Print MENU CHARGE DC IN DC power input Power switch SD memory card slot USB port Weight : Approx. 1.2kg 10 OUTLINE DIAGRAM (Unit:mm) Saddle Scale(inch) Scale(mm) Connector Spacing: 0 to 133 mm Saddle Connector Scale (inch) Scale (mm) Spacing: 0 to 348 Name prate 540±2 Name plate Lock nut Element holder Cursor 320±2 36±0.5 (114) Mounting spring BNC Connector Lock nut Element holder Cursor inch 52.5±0.5 90max. Weight : Approx. 0.8kg 52.5±0.5 90max. 36±0.5 Weight : Approx. 0.6kg Detector FSD12 (Small type) Detector FSD22 (Small diameter) Connector Scale(inch) Saddle Name plate 54±2 Scale(mm) Name plate Distance between two sensors 0 to 330 Sensor A 530±2 37±1 Wire rope 46±1 Lock nut Element holder Cursor ø4.3 8.5 8 φ26 90max. 205max. 33±0.5 Cable 5000 −0 +200 CONNECTION DIAGRAM G+ Weight : Approx. 1.7kg 44±1 TO FLOW TRANSMITTER Weight : Approx. 1.3kg Detector FSD32 (High-temperature) Detector FSD41 (Middle type) (ø19) 11 FSC, FSD OUTLINE DIAGRAM (Unit:mm) Name plate Wire rope Mounting spring BNC connector 92±2 Sensor unit (114) 78±1 L Detector A (ø19) Type. Mfd. 67±2 Absorber unit Ser.No. ø4.3 8.5 8 Cable BNC Connector Made in Japan 5000 −0 +200 Frame Weight : Approx.2.2kg Detector FSD51 (Large type) Clip Straight plug (ø12.3) AO AI ch1 AI ch2 (ø5) (H) W±1 100±5 1500 -0 +100 Weight : approx. 0.1kg Code color Black (BK) White (W) Red (R) Green (G) Yellow (Y) Brown (BN) Clip color Red (R) Black (BK) Red (R) Black (BK) Red (R) Black (BK) (+) (−) (+) (−) (+) (−) Mark AO AI ch1 Type FSDP2 FSDP1 FSDP0 Diameter (mm) φ40 to φ200 φ100 to φ400 φ200 to φ1000 L 260±1.2 260±1.2 350±2.0 H 70 72 90 W 57 57 85 Weight Approx. (kg) 0.8 0.9 2.0 AI ch2 Analog input/output cable Detector FSDP (Detector for flow velocity profile measurement) Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan
EDSX6-139H 价格&库存

很抱歉,暂时无法提供与“EDSX6-139H”相匹配的价格&库存,您可以联系我们找货

免费人工找货