0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX6-140D

EDSX6-140D

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX6-140D - ULTRASONIC FLOWMETER - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX6-140D 数据手册
ULTRASONIC FLOWMETER < DATA SHEET This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics and digital signal processing technologies, we realized a compact and lightweight design, and improved the accuracy and easiness to use while keeping with anti-bubble performance. The communication function (MODBUS: Option) is also applicable. SERIES > FSV, FLS/FSG/FSD FEATURES 1. Compact and light-weight Thanks to the adoption of the latest electronics the flow transmitter size and mass are 1/3 of our traditional instrument. 2. Full variety of sensors The flowmeter can be used with various types of sensors applicable for wide range of pipe size (ø13 to ø6000mm) and fluid temperature (-40 to +200°C). 3. High accuracy The flowmeter is designed for high accurary (better than ±1.0% of rate) by dynamic correction of fully-developed flow profile. Reynolds Number is calculated and a meter factor (K) is automatically applied for best accuracy at all flow velocities. Further, the adoption of new sound velocity measurement system permits measurements of fluids of unknown sound velocity. Moreover, affection from fluid temperature and pressure is negligible (AutoTemp./Press. compensation). 4. Excellent resistance against aerated flow Fuji's unique ABM feature improves measurement reliability for different flow like slurries, sludge, raw sewage and bubble-contained flow (acceptable up to air bubble of 12% volume at 1m/s velocity). 5. Quick response With the use of high-speed micro-processor suited for digital signal processing, the fast response time is realized. 6. Multi-lingual The following languages are supported for display: Japanese (Katakana), English, German French, and Spanish. 7. Excellent performance and easy operation LCD and function keys are allowing easy configuration and trouble shooting. − LCD with back light − Easy mounting of sensor − Trouble shooting − Easy operation with keypad on the front surface of the flow transmitter (FSV···S) Flow transmitter (FSV···S) Detector (FLSE12) (FLSE22) Detector (FSD22) Detector (FSD32) Detector (FSG) SPECIFICATIONS Operational specifications System configuration: Single-path system of a flow transmitter (Model FSV) and a detector (Model FLS/FSG/FSD) Applicable fluid: Homogenous liquid where the ultrasonic signal can be transmitted Bubble quantity: 0 to 12vol% (for pipe size 50A, water, velocity 1m/s) Fluid turbidity: 10000mg/L max. Type of flow: Fully-developed turbulent or laminar flow in a full-filled pipe Flow velocity range: 0 to ±0.3 ... ±32m/s EDSX6-140d Date Apr. 1, 2011 FSV, FLS/FSG/FSD Power supply: 100 to 240V AC +10%/-15%, 50/60Hz; or 20 to 30V DC Signal cable (between detector and converter): Coaxial cable (5m standard, 300m (60m for popular detector (FLS)) max.) Heat resistance: 80°C Installation environment: Non-explosive area without direct sunlight, corrosive gas and heat radiation. Ambient temperature: Flow transmitter: -20 to +55°C Detector: -20 to +60°C -20 to +80°C (for FLSE 2 2-A only) Ambient humidity: 95%RH max. Grounding: Class D (100 Ω) Arrester: Provided as standard at output and power supply Applicable piping and fluid temperature: Detector Mounting Fluid method temperature range (Note 3) 9th digit in ø25 to ø100 mm Plastic (PVC, etc.) (Note 1) code symbol FLSE12 Metal pipe (SS, steel pipe, Y... -20 to ø50 to ø100 mm copper pipe, aluminum pipe, +100°C etc.) (Note 2) V method A... 0 to Plastic (PVC, etc.) (Note 1) +120°C Metal pipe (SS, steel pipe, (Note 4) FLSE22 ø50 to ø225 mm copper pipe, aluminum pipe, Heat shock etc.) (Note 2) resistance 150°C, 30min Pipe size Applicable pipe (inner diameter) material Performance specifications Rated accuracy: Detector Pipe size (diameter) ø25 to ø50 mm Plastic FLSE12 ø50 to ø100 mm Popular type ø50 to ø100 mm Metal pipe ø50 to ø225 mm Plastic FLSE22 ø50 to ø225 mm ø13 to ø50 mm FSD22 ø50 to ø100 mm Common type FSGS32 ø50 to below ø300 FSD32 FSGS51 ø300 to ø6000 mm FSGS31 ø50 to below ø300 FSGS41 FSGS50 ø300 to ø6000 mm Applicable pipe material Flow velocity Accuracy 2 to 32m/s 0 to 2m/s 2 to 32m/s 0 to 2m/s 2 to 32m/s 0 to 2m/s ±2.0% of rate ±0.04m/s ±1.0% of rate ±0.02m/s ±2.0% of rate ±0.04m/s ±1.0% of rate ±0.02m/s ±2.0% of rate ±0.04m/s ±1.5% to ±2.5% of rate ±0.03 to ±0.05m/s ±1.5% of rate ±0.03m/s ±1.0% of rate ±0.02m/s ±1.0% of rate ±0.0075m/s ±1.5% of rate ±0.03m/s ±1.5% of rate ±0.0113m/s Popular type 2 to 32m/s 0 to 2m/s 2 to 32m/s Metal pipe 0 to 2m/s 2 to 32m/s 0 to 2m/s 2 to 32m/s 0 to 2m/s 2 to 32m/s 0 to 2m/s Plastic, metal pipe 0.75 to 32m/s 0 to 0.75m/s 2 to 32m/s 0 to 2m/s 0.75 to 32m/s 0 to 0.75m/s Response time: 0.5s (standard mode) 0.2s as selected (quick response mode) Power consumption: 15VA max. (AC power supply) 6W max. (DC power supply) -40 to 100°C FSD22 ø13 to ø100 mm V method FSGS3 ø50 to ø300 mm Plastic (PVC, etc.) (Note 1) ø200 to Metal pipe (SS, steel pipe, FSGS41 ø1200 mm -40 to 80°C copper pipe, aluminum pipe, V or Z method ø200 to etc.) (Note 2) FSGS5 ø6000 mm FSD32 ø50 to ø400 mm -40 to 200°C Common type Functional specifications 4 to 20mA DC (1 point) Load resistance: 1 kΩ max. Digital output: Forward total, reverse total, alarm, acting range, flow switch, total switch assignable arbitrarily (1) Mechanical relay contact (isolated, socket provided, arrester incorporated) • Output: 1 point • Normal: Open/Close selectable • Contact capacity: 240V AC, 30V DC, 1A • Output frequency: 1P/s max. (pulse width: 50, 100, 200ms) (2) Transistor contact (isolated, open collector, arrester incorporated) • Outputs: 2 points • Normal: ON/OFF selectable • Contact capacity: 30V DC, 0.1A • Output frequency: 1000P/s max. (pulse width: 5, 10, 50, 100, 200ms) Digital input: 1 point (no-voltage contact) (option)/ Set zero, Preset total assignable Serial communication (option): RS-232C equivalent or RS-485, isolated, arrester incorporated Connectable quantity: 1 unit (RS-232C)/up to 31 units (RS-485: MODBUS) Baud rate: 9600, 19200, 38400bps Parity: None/Odd/Even selectable Stop bits: 1 or 2 bits selectable Analog signal: Note 1: If the pipe material is PP or PVDF, select FSGS31, FSGS41 or FSGS5. Note that the wall thickness is 15mm or less for PP, and 9mm or less for PVDF. Note 2: For cast iron pipe, lining pipe, old steel pipe or others through which the ultrasonic signal could not be transmitted easily, select FSGS31,FSGS41 or FSGS50. Lining material: Tar epoxy, mortar, rubber, etc. * In case the lining is not glued to a pipe, the measurement may be impossible. Straight pipe length: Typically 10D for upstream and 5D for dowstream. (D: Pipe inner diameter) Refer to conditions on straight pipe for details (Japan Electric Measuring Instruments Manufacturers' Association Standard JEMIS-032). Note 3: If silicone-free grease is used as acoustic coupler, the fluid temperature range is 0 to 60°C regardless of the detector. Note 4: When the 9th digit in the code symbol is “A”, the applicable piping diameter is up to 150mm. 2 Cable length: 15m max. (RS-232C)/1km max. (RS-485) Data: Flow velocity, flow rate, forward total, reverse total, status, etc. Display device: 2-color LED (Normal: green, Extraordinary: red) LCD with 2 lines of 16 characters and back light Indication language: Japanese (Katakana)/English/French/ German/Spanish (changeable) Flow velocity/flow rate indication: Instantaneous flow velocity, instantaneous flow rate indication (minus indication for reverse flow) N umerals: 8 digits (decimal point is counted as 1 digit) Unit: Metric/Inch system selectable Metric system Velocity m/s Flow rate L/s, L/min, L/h, L/d, k L / d , M L / d , m 3/ s , m 3/min, m3/d, km3/d, Mm 3/d, BBL/s, BBL/ min, BBL/h, BBL/d, kBBL/d, MBBL/d Note: The ”gal” means USgal. Inch system ft/s gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/ d, ft3/s, ft3/min, ft3/d, Kft 3/d, Mft3/d, BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d, MBBL/d Flow switch: Lower limit, upper limit configurable independently Digital output available for status at actuated point Total switch: Forward total switching point configurable Digital output available when actuated External total preset: Preset total settable upon contact input setting Physical specifications Type of enclosure: Flow transmitter: FSV···S: IP66 FSV···H: IP67 (With large LCD) Detector: FLS (popular type): IP65 (When waterproot BNC connector is provided) FSG (common type): IP67 (Silicone compound is filled on the terminal part when wiring) FSG (submersible type): IP68 (submersible in water for 5 days) FSD (small diameter and high temperature type): IP52 Mounting method: Flow transmitter: Mounted on wall or by 2B pipe Detector: Clamped on pipe surface Acoustic coupler: Silicone rubber, silicone grease or siliconefree grease Note: The acoustic coupler is a medium that eliminates a gap between detector and pipe Type of acoustic coupler: Type Silicone rubber (KE-348W) Silicone grease (G40M) Silicone-free Grease for grease high (HIGH Z) temperature (KS62M) -30 to +250°C Total indication: Forward or reverse total value indication (negative indication for reverse direction) N umerals: 8 digits (decimal point is counted as 1 digit) Unit: Metric/Inch system selectable Metric system Total Inch system mL, L, m3, km3, Mm3, gal, kgal, ft3, kft3, Mft3, mBBL, BBL, KBBL mBBL, BBL, kBBL, ACRE-ft Configuration: Fully configurable from the 4-key pad (ESC, , , ENT) Zero adjustment: Set zero/Clear available External zero adjustment: Set zero available upon digital input setting Damping: 0 to 100s (every 0.1s) for analog output and flow velocity/flow rate indication Low flow rate cutoff: 0 to 5m/s in terms of flow velocity Alarm: Digital output available for Hardware fault or Process fault Burnout: Analog output: Hold/Overscale/Underscale/Zero selectable Flow rate total: Hold/Count selectable Burnout timer: 0 to 100s (every 1s) Bi-directional range: Forward and reverse ranges configurable independently. Hysteresis: 0 to 10% of working range Working range applicable to digital output Auto-2 range: 2 forward ranges configurable independently Hysteresis: 0 to 10% of working range Working range applicable to digital output Fluid temperature Teflon piping -40 to +150°C -30 to +150°C 0 to +60°C In case of Teflon piping, use grease. Procure silicone grease (G40M), if necessary, as an optional accessory. Material: Flow transmitter: Aluminum alloy Detector: Detector Sensor housing Sensor cover Guide rail – FLSE1 PBT SUS304 – FLSE2 PBT SUS304 – FSD22 PBT Aluminum alloy + plastic FSGS3 PBT SUS304 SUS304 + plastic – FSGS41 PBT SUS304 FSGS5 FSD32 SUS304 – SUS304 + aluminum alloy 3 FSV, FLS/FSG/FSD Signal cable: FLY3 (applicable detector: FLS) • Structure: Heat-resisting high-frequency coaxial cable (3D2V) • Sheath: Flame-resisting PVC • Outer diameter: ø5mm • T ermination: M3 amp terminal (flow transmitter side) and BNC connector (sensor side) FLY8, FLY9 (applicable detector: FSG, FSD) • Structure: High frequency coaxial cable (double shield) • Sheath: Black flame-resisting PVC • Outer diameter: ø7.3mm • T ermination: M3 amp terminal (flow transmitter side) and M4 amp terminal (FLY8).Note, however, that the detecter side of FSD22 and FSD32 is provided with BNC connector (FLY9). • Mass: Approx. 90g/m Flow transmitter FSV···S (IP66): H170×W142×D70mm Flow transmitter FSV···H (IP67): H277×W244×D95mm Detector: H50×W228×D34mm (FLSE1) H50×W348×D34mm (FLSE2) H90×W320×D53mm (FSD22) H46×W410×D50mm (FSGS3) H46×W54×D37mm (FSGS41) H67×W78×D84mm (FSGS5) H205×W530×D52mm (FSD32) Mass: Flow transmitter 1.5kg Flow transmitter 4.5kg Detector: 0.3kg 0.4kg 0.6kg 0.6kg 0.3kg 1.2kg 1.6kg (indoor type): (outdoor type): (FLSE1) (FLSE2) (FSD22) (FSGS3) (FSGS4) (FSGS5) (FSD32) PC Loader software Provided as standard •Compatible model is PC/AT compatible instrument. •Operation is undefined for PC98 series (NEC). •Main functions: Software for Main unit parameter setting/change on PC •OS: Windows 2000/XP •Memory requirement: 125MB min. •Disk unit: CD-ROM drive compatible with Windows 2000/XP •Hard disk capacity: Minimum vacant capacity of 52MB or more Note: O ptional communication board (specified at the 5th digit of code symbols) and loader cable (Model ZZP*TK4J1236) are additionally necessary for RS232C serial communication. Note: USB-RS232C converter For PC that does not support RS-232C serial interface, a converter is necessary for connecting the PC and main unit. USB-RS232C converter should be combined with the above loader cable. USB-CVRS9 (manufactured by Sanwa Supply) Dimensions: MEASURING PRINCIPLE With ultrasonic pulses propagated diagonally between the upstream and downstream sensors, flow rate is measured by detecting the time difference obtained by the flow of fluid. Detector Upstream sensor θ Flow velocity t1 t2 D CONFIGURATION DIAGRAM (1) Single-path system (V method) Cable Detector Flow transmitter DC 4 to 20mA Output signal Flow transmitter Digital signal (Up to 2 point) Downstream sensor (2) Single path system (Z method) Cable MOUNTING OF DETECTOR Ultra sonic oscillator Plastic wedge Pipe Detector Flow transmitter DC 4 to 20mA Digital signal (Up to 2 point) Lining 4 DETECTOR SELECTION GUIDE Type FLSE12 FLSE12 FLSE22 FLSE22 2-Y 2-Y Fluid Mounting temperature [°C] method -20 to 100 -20 to 100 2-A 0 to 120 2-A 0 to 120 V V Inner diameter of piping ø (mm) 13 25 25 50 100 100 200 250 300 400 1000 3000 6000 P 50 50 50 M 100 PM , PM , 150 225 FSGS32 Note) FSGS31 FSGS41 -40 to 80 V V Z 50 Px, P M , 200 200 200 200 300 Px, P M , Px, P M , 600 1200 3000 6000 FSGS51 Note) FSGS50 FSD22 FSD32 -40 to 100 -40 to 200 V Z V V Z Classification of piping materials 13 Px, P M , Px, P M , Px, P M , 50 100 Px, P M , 150 250 Px, P M , 400 Px : PP PVDF , P : Plastic (PVC, etc.) M : Msetallic piping (steel pipe, copper pipe, aluminum, etc.) Note: The ultrasonic signal cannot be transmitted easily when the classification of piping material is Px or the turbidity is high. In such a case, a preliminary check by a portable ultrasonic flowmeter is recommended. CODE SYMBOL 12345678 9 10 11 12 13 14 Description (Destination) (4th digit) Standard (English) 12345678 FSV E Y A B Y 1 Y Description Small diameter sensor (ø13 to ø100) V method High-temperature sensor *1 (ø50 to ø400) V or Z method FSD2 2 0S1 FSD3 2 0Y1 (Communication) (5th digit) None RS232C+DI RS485+DI Y 1 4 S H Y A (Use) (6th digit) Single measuring path (Power supply) (7th digit) AC100 to 240V 50/60Hz DC20 to 30V (Case structure) (9th digit) IP66 IP67 (Wire connection port) (10th digit) Weatherproof gland provided [G1/2 and G3/8 (internal threads)] Union (for pilica) with gland [G1/2 female screw] (when "H" is specified 9th digit) (Combination with explosion-proof detector) (11th digit) None Y A B C A B C N E A (Parameter setting) (12th digit) None Setting provided Setting provided + tag Tag (Mounting method) (13th digit) Pipe mount (if the 9th digit is S) Wall mount Pipe mount (if the 9th digit is H) (Area) (14th digit) America Europe, Middle East, Africa Asia *1: For turbid fluid or old pipe, cast iron pipe, mortar lining pipe or others through which the ultrasonic signal could not be transmitted easily, use an optional guide rail (TK4C6164C1), and carry out mounting by Z method. Applicable diameter range V method: ø50 to ø250 Z method: ø150 to ø400 Note: As standard acoustic coupler, silicone rubber (KE-348W) is provided for small diameter sensor, or grease for high temperature (KS62M) for high-temperature sensor. Y 5 FSV, FLS/FSG/FSD CODE SYMBOL 12345678 9 10 11 12 13 Description 12345678 9 10 F SGS 3 3 4 5 5 2 1 1 1 0 Y1 Y 1 Type (5th and 6th digits) Small sensor 2MHz (ø50 to ø300) V method Small sensor 1MHz (ø50 to ø300)*2 Middle sensor 1MHz (ø200 to ø1200) V or Z Large sensor 1MHz (ø200 to ø6000) method Large sensor 0.5KHz (ø200 to ø6000)*2 Y A B C Y A Acoustic coupler (10th digit) None*5 Silicon rubber (KE348) Silicone-free grease (HIGH-Z) (Note 2) Silicone grease (G40M) (Note 2) Additional specification (11th digit) None Tag plate Wire rope for mounting (12th digit) Specify it in the case of FSGS41 or FSGS5. None Nominal diameter: up to ø500mm Nominal diameter: up to ø1000mm Nominal diameter: up to ø1500mm Nominal diameter: up to ø3000mm Can be specified Nominal diameter: up to ø6000mm only for FSGS5 FLSE 12 22 3 Description Type (4th, 5th and 6th digits) Small diameter sensor, 2MNz (ø25 to ø100mm) Small sensor, 2MHz (ø50 to ø225mm) (Note 1) V method Y A B Y A Y B Acoustic coupler (7th digit) (Note 2) None Silicone rubber Silicone-free grease Fluid temperature range (9th digit) -20 to +100°C 0 to +120°C Optional specification (10th digit) None Tag Y A B C D E Note 1: When the 9th digit in the code symbol is “A”, the applicable piping diameter is up to 150mm. Note 2: Normally select silicone rubber as acoustic coupler. Silicone rubber in tube (100g) is furnished. If you place an order for several units, 1 tube may suffice for every 5 units. Select silicone-free grease for semiconductor manufacturing equipment or the like that is vulnerable to silicone. The silicone-free grease is water-soluble and, therefore, cannot be used in environment exposed to water or on piping subjected to a condensation. Since the grease does not set, a periodic maintenance (cleaning, refilling every about 6 months at normal temperature) is necessary. *2: For aging pipes, cast iron pipes or mortar-lined pipes that interrupts the propagation of ultrasonic signals, select FSGS31 or FSGS50. *3: Procure type FLY for the signal cable. *5: Silicone rubber (KE-348W) is provided as a standard accessory to fill the wiring mold. (It can also be used as an acoustic coupler.) If an additional acoustic coupler is required, select one among A, B and C. 12345678 9 10 11 12 13 F SGS 3 3 4 5 5 2 1 1 1 0 A1 1 Description Type (5th and 6th digits) Small sensor 2MHz (ø50 to ø300) V method Small sensor 1MHz (ø50 to ø300)*2 Middle sensor 1MHz (ø200 to ø1200) V or Z Large sensor 1MHz (ø200 to ø6000) method Large sensor 0.5KHz (ø200 to ø6000)*2 B C D E F G H J K L M N P Q R Z A C Y A Dedicated signal cable (9th digit) 10m 20m 30m 40m 50m 60m 70m 80m 90m 100m 110m 120m 130m 140m 150m Specified length (Contact us if length is more than 150m. Max. length is 300m.) Acoustic coupler (10th digit) Silicon rubber (KE348) Silicone grease (G40M) (Note 2) Additional specification (11th digit) None Tag plate Wire rope for mounting (12th digit) Specify it in the case of FSGS41 or FSGS5. None Nominal diameter: up to ø500mm Nominal diameter: up to ø1000mm Nominal diameter: up to ø1500mm Nominal diameter: up to ø3000mm Can be specified Nominal diameter: up to ø6000mm only for FSGS5 Y A B C D E *2: For aging pipes, cast iron pipes or mortar-lined pipes that interrupts the propagation of ultrasonic signals, select FSGS31 or FSGS50. 6 CODE SYMBOL • For detector FLS 12345678 • For detector FSG and FSD 12345678 FLY 3 0 0 0 0 0 0 0 0 0 Z 0 1 1 2 2 3 4 5 6 Z 5 0 5 0 5 0 0 0 0 Z 1 Description Type of sensor (4th digit code) (for FLS) Cable length (5, 6 and 7th digit) 5m 10 m 15 m 20 m 25 m 30 m 40 m 50 m 60 m Others (contact us) FLY 8 9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 Z 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 1 2 3 4 5 Z 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 0 0 0 0 0 Z 1 Description Type of sensor (4th digit) Small and large sensor (for FSG) Small dia and hight temp sensor (for FSD) Cable length (5,6 and 7th digit) 5m 10 m 15 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 100 m 110 m 120 m 130 m 140 m 150 m Others (contact us) Conditions on straight pipe Classification Upstream side Note: Must be procured unless the sensor is a submersible type. ( D : Inside diameter of pipe) Downstream side L 5D 10D or more L 10D 90 bend Detector 10D or more L 10D L 50D Tee 10D or more 0.5D or more L 30D D L 5D Diffuser 1.5D L 10D Reducer L 50D L 30D Various Valve In case that flow control valve exists on upstream side. Stop valve Check valve L 50D Pump P L 10D In case that flow control valve exists on downstream side. (Note) The source : JEMIS-032 7 FSV, FLS/FSG/FSD OUTLINE DIAGRAM (Unit:mm) U bolt (M8) (option) 2.5 2.5 75 Mtg. plate 1 142 70 1 10 9 U bolt (M8) (option) Mtg. hole 20 2- ø9 72 10 Ultrasonic Flow Meter 170 200 (233) ESC ENT 277 TIME DELTA-C 312 25 SS tag (option) Cable gland Mtg. pipe Earth terminal (M4) 153 Bracket (option) 5.7 Mtg. pipe 95 220 14 230 Earth terminal (M4) For sensor cable (PF3/8) 39 40 For power supply & output cable (PF1/2) 40 40 40 For sensor cable (PF1/2) For power supply & output cable (PG13.5) Flow transmitter : FSV···S (IP66) SS tag (option) L Flow transmitter : FSV···H (IP67) H Sensor BNC connector Frame Lock clip 34 Spacing (Adjustable every 3mm) Type Pipe size (mm) 28 (50) L 228 348 H 31 30 Spacing 21 to 120 21 to 240 Mass. approx (kg) 0.3 0.4 FLSE12 25 to 100 FLSE22 50 to 225 Detecter (type : FLSE 2) (popular type) 8 OUTLINE DIAGRAM (Unit:mm) Saddle Connector Connector Scale(inch) Saddle Scale(mm) Distance between two sensors 0 to 133 Distance between two sensors 0 to 330 Scale (inch) mm Scale (mm) Name plate Element holder 320 Lock nut Lock nut Element holder Cursor Cursor 36 90 max. φ26 90max. 205max. 33±0.5 52.5 Detector FSD22 (Small diameter sensor) 44±1 Detector FSD32 (High-temperature sensor) Frame 5 P Name plate 47 Spacing : 0 to 270 410±2 400 Sensor 5 5 P Frame 410±2 400 Sensor 5 530±2 50±1 33 Chain Mounting spring VIEW FROM P Frame guide Name plate 50±1 33 47 Spacing : 0 to 270 Chain Mounting spring 46±1 Frame guide (10) (10) VIEW FROM P (Common type) 46±1 (Submersible type) Detector FSGS3 (Small sensor) Name plate Name plate 84±1 84±1 114 114 78±1 Sensor Wire rope Mounting spring 67±1 78±1 Sensor L(cable length (m) : specified by order) Wire rope Mounting spring 67±1 (Common type) (Submersible type) Detector FSGS5 (Large sensor) 9 Ø19 ø19 L (cable length (m) : specified by order) inch FSV, FLS/FSG/FSD OUTLINE DIAGRAM (Unit:mm) Name plate Name plate 54±1 114 54±1 Sensor 114 Sensor Wire rope 37±1 Mounting spring 37±1 L (cable length (m) : specified by order) Wire rope Mounting spring 46±1 46±1 (Common type) Ø19 (Submersible type) Detector FSGS41 (Middle sensor) Signal cable : FLY3 (For FLS) ø15 BNC connector Signal cable : FLY8 (For FSG) 8 3-ø4.3 41 To Detector ø11 L (cable length (m) : specified by order) L (cable length (m) : specified by order) 30 To Detector ø5 ø7.3 To Flow transmitter To Flow transmitter ø3. 5.5 2 L : By specification when ordered. 3-ø3.2 L : By specification when ordered. 5.5 Signal cable : FLY9 (For FSD) ø14.5 BNC connector Loader cable : ZZP*TK4J1236 34 Connector 67 ø11 L (cable length (m) : specified by order) ø7.3 30 46 To Detector To Personal computer 3.2±0.2 (m) ø6.9 To Flow transmitter To Flow transmitter Terminal cap (Red) 3ø3 .2 Terminal cap (Yellow) Terminal cap (Black) Red TXD 5.5 Yellow RXD RS-232C Black COM 3-ø3.2 L : By specification when ordered. 10 5.5 Ø19 CONNECTION DIAGRAM Earth terminal (M4) AC power supply 1 2 3 4 DC power supply 1 2 3 4 Option 1 2 3 4 G SHILD TXDR2 TXDR1 RS-485 + L N + − DI1 AC100 to 240V 50/60Hz DC20 to 30V Status input (DI) 11 12 13 1 2 To flow transmitter 3 4 1 2 3 4 5 6 7 8 9 10 + − + − + − + − GND HF1 GND HF2 *1 SH DI1 GND RXD RS-232C TXD DO1 TR out DO2 TR out DO3 RELAY I out *1 SH Max. DC30V, 0.1A Max. AC240V/ DC30V, 1A To downstream-side sensor Status input (DI) To upstream-side sensor *1) Only for double shield coaxial cable (type FLY8, 9) SCOPE OF DELIVERY •Flow transmitter (provided with U-bolt and nuts for pipe mount) •Detector (provided with mounting fixture and acoustic coupler) *The acoustic coupler is option for popular type detectors. •Signal cable •CD-ROM (contains instruction manual, loader software) ITEMS DESIGNATED ORDERING 1. Detector code symbols 2. Flow transmitter code symbols 3. Signal cable code symbols 4. For large sensor: Mounting pipe size 5. Tag No. as necessary 6. If parameter setting is specified, send back the attached parameter specification table duly filled. OPTIONAL ACCESSORIES Name 1 Guide rail for high-temperature sensor 2 PC Loader cable 3 Silicon grease (G40M) 4 Silicone rubber (KE 348W) 5 Silicone-free grease (HIGH Z) 6 High-temperature grease (KS62M) 7 Fuse for AC power 8 Fuse for DC power 9 Wire rope for mounting the sensor Spring Wire rope Nomal diameter: up to ø500mm Nomal diameter: up to ø1000mm Nomal diameter: up to ø1500mm Nomal diameter: up to ø3000mm Nomal diameter: up to ø6000mm ZZP*TK464686C1 ZZP*TK464686C2 ZZP*TK464686C3 ZZP*TK464686C6 ZZP*TK464686C13 ZZP*TK745007P1 Drawing No. ZZP*TK4C6164C1 ZZP*TK4J1236C1 ZZP*45231N5 ZZP*45735N2 ZZP*TK7M0981P1 ZZP*TK7G7983C1 ZZP*TK7N3827P8 ZZP*TK7J1005P1 11 FSV, FLS/FSG/FSD Setting item ID No Language System unit Flow unit Total unit Measuring conditions Outer diameter Pipe material Wall thickness Lining material Lining thickness Kind of fluid Viscosity Sensor mount Sensor type Transmission voltage Damping Cut off 1st line Display 1st line decimal point position 2nd line 2nd line decimal point position Range type Full scale 1 Full scale 2 Analog output Range HYS. Burnout (current) Burnout timer Output low limit Output high limit Rate limit Rate limit timer Initial value 0000 Total output English Metric m3/h m 3 Setting value Setting item Total mode Total rate Total preset Pulse width Burnout (total) Burnout timer DO1 output type (Note 1) DO1 output actuation DO2 output type DO2 output actuation DO3 output type DO3 output actuation DI1 input type DI1 input actuation Operation mode Communication Communication mode Baud rate Parity Stop bit Station No. Initial value Stop 0m3 0m3 50.0msec Hold 10sec Not used ON when actuated Not used ON when actuated Not used ON when actuated Not used ON when actuated Standard RS-232C 9600bps Odd 1 bit 1 Setting value 60.00mm PVC pipe 4.00mm Without lining − Water 1.0038×10-6m2/s V metod FLS_12 80Vpp 5.0sec 0.150m /h 3 Flow velocity (m/s) ****.*** Flow rate (m3/h) ****.*** Single range 15.000m3/h 0.000m3/h 10.00% Hold 10sec -20% 120% 0.000m3/h 0sec Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that conditions 1 and 2 shown below are satisfies. Condition 1 : Flow span-1*[m3/s] total pulse value*[m3] Flow span-1*[m3/s] total pulse value*[m3] 1000 [In the case of DO1 and DO2] 1 [In the case of DO3] 1000 2 × total pulse width [ms] Output conditions Condition 2 : * In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan Output conditions
EDSX6-140D 价格&库存

很抱歉,暂时无法提供与“EDSX6-140D”相匹配的价格&库存,您可以联系我们找货

免费人工找货