POWER RELAY
2 POLES - 5A Low Profile Type
FTR-F1 Series
■■ FEATURES
• Low profile (height: 16.5mm)
• DPST/DPDT 5A
• High insulation
•
•
•
(due to its reinforced insulation construction)
Insulation Distance (between coil and contacts): 8mm min.
Dielectric strength : 5,000 VAC
Surge strength : 10,000 V
Pin configuration compatible to VB
UL, CSA, VDE, CQC recognized
RoHS compliant (Please see page 6 for more information)
■■ Part Numbers
[Example]
(a)
(b)
(c)
FTR-F1
(a)
-
A
(b)
Relay type
Contact configuration
Coil type / enclosure
(d)
Coil rated voltage
(e)
Contact material / TV type
(f)
Special type
A
(c)
005
(d)
FTR-F1
A
C
A
D
005
V
T
Nil
RG
V
(e)
-
RG
(f)
: FTR-F1 series
: 2 form A (SPST-NO)
: 2 form C
: Standard type (530mW)
: High sensitivity type (400mW contact material V type only)
: 1.5....110VDC
Coil rating table at page 3
: Gold plated silver alloy(standard type)
: Gold plated silver alloy
(TV-3 rating type, only for 2 form A standard coil type)
: Standard type
: Transparent cover type
Actual marking does not carry the type nameL "FTR"
E.g.: Ordering code: "FTR-F1AA005V", actual marking: "F1AA005V"
1
FTR-F1 Series
■■ Specifications
Item
Standard type
F1 (A, C) A
()V
2 form A
(DPST-NO)
2 form C
Contact Configuration
data
Construction
Material
Resistance
Contact rating
Max. carrying current
Timing
data
Life
Insulation
Surge strength Coil to contacts
Creepage
8mm
Voltage
250V
Pollution
3
Category
Other
Vibration resis- Misoperation
tance
Endurance
Shock resistance
Misoperation
Endurance
Dimensions / weight
Sealing
without bounce, no diode
without bounce, no diode
At rated load
At rated load
10000V / 1.2 x 50μs standard wave
8mm
Material group
No frost
3000VAC (50/60Hz), 1 minute
Clearance
EN61810-1,
VDE0435
Remarks / conditions
Single
Movable: Gold plate silver tin oxide (AgSnO2)
Stationary: Silver tin oxide
Max.100mΩ at 6VDC, 1A
Initial
5A, 250VAC / 24VDC
Resistive
7A
400VAC, 300VDC
1250VA / 120W
10 mA, 5VDC
530mW, 110V type: 550mW
400mW
260mW, 110V type: 270mW
225mW
-40ºC ~ +75ºC (at rated voltage)
-40ºC ~ +70ºC (Transparent cover type, -RG)
Operate
Max. 15ms
Release
Max. 5ms
Mechanical
Min. 20 x 10⁶ operations
Electrical
AC contact rating
Min. 100 x 103 operations
(resistive)
DC contact rating
Min. 100 x 103 operations
Lamp load (TV-3)
25 x 103 operations min.
Insulation resistance
Min. 1000MΩ at 500VDC
Dielectric
Open contacts
1000VAC (50/60Hz), 1 minute
strength
Coil contact
5000VAC (50/60Hz), 1 minute
Adjecent contacts
:
2 form A
(DSDT-NO)
Sensitive type
F1 (A, C) D
()V
2 form A
(DPST-NO)
2 form C
(DPDT)
Max. switching voltage
Max. switching power
Min. switching load *1
Rated power (20oC)
Operate power (20oC)
Operating temperature range
Coil
*1
TV-3 rating
F1 AA ( ) T
III a
C / 250V (reference voltage) (VDE 0110b)
10Hz ~ 55Hz ~ 10Hz single amplitude
0.825mm
10Hz ~ 55Hz ~ 10Hz single amplitude
1.65mm
Min. 100m/s² (11 ± 1ms)
Min. 1,000m/s² (6 ± 1ms)
12.8 x 29.0 x 16.5 mm / approx. 12.0g
Flux proof RTII
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual load
before production since reference values may vary according to switching frequencies, environmental contions and
expected reliability levels.
2
FTR-F1 Series
■■ Coil Data
530mW standard type
Coil code Rated Coil Voltage Coil Resistance +/-10% Must Operate Voltage* Must Release Voltage*
(VDC)
(Ω)
(VDC)
(VDC)
1.5
1.5
4.2
1.05
0.15
005
5
47
3.5
0.5
006
6
68
4.2
0.6
009
9
155
6.3
0.9
012
12
270
8.4
1.2
018
18
610
12.6
1.8
024
24
1,100
16.8
2.4
048
48
4,400
33.6
4.8
060
60
6,800
42.0
6.0
110
110
22,000
77.0
11.0
Rated Power
(mW)
530
550
400mW high sensitive type
Coil code Rated Coil Voltage Coil Resistance +/-10% Must Operate Voltage* Must Release Voltage*
(VDC)
(Ω)
(VDC)
(VDC)
1.5
1.5
5.6
1.125
0.15
003
3
22.5
2.25
0.3
005
5
62
3.75
0.5
006
6
90
4.5
0.6
009
9
202
6.75
0.9
012
12
360
9
1.2
024
24
1,440
18
2.4
048
48
5,760
36
4.8
Rated Power
(mW)
400
Note: All values in the table are valid at 20oC and zero contact current, unless otherwise specified.
*
:
Specified operated values are valid for pulse wave voltage.
Note: Please use at rated coil voltage. Please refer to characteristic data and set up adequate voltage in case of use at over voltage.
Care shall be taken on the heat generated on PC board when maximum carrying current exceeds 10A. Please perform the confirmation test with actual
conditions.
■■ Safety Standards
Type
UL
Compliance
UL 508
CSA
C22.2 No. 14
File No. LR 40304
VDE
CQC
IEC/EN61810-1
EN60065 clause 14.6.1 (FTR-F1AA ( )T)
EN60335-1 clause 15.3; 16.3; 29.1; 29.2; 29.3
EN60730-1 clause 12.2; 13.2; 20.1; 20.2; 20.3
GB/T21711.1, GB15092.1
(No.17002164350)
Contact rating
Flammability: UL 94-V-0 (plastics)
5A, 24VDC (resistive)
5A, 250VAC (resistive)
1/6 hp, 125VAC
1/4 hp, 250VAC
Pilot duty: C300
Pilot duty: R300 (FTR-F1CA( )V)
TV-3 (FTR-F1AA( )T)
(except for -RG type)
5A, 250 VAC (cosφ=1)
2A, 250 VAC (cosφ=0.4)
5A, 24VDC (0ms)
2A/32A, 250VAC (FTR-F1AA( )T)
5A, 250VAC (FTR-F1CA( )V)
3
FTR-F1 Series
■■ Characteristic Data (Reference)
* Characteristic data is not a guaranteed value, but measured values of samples from production line.
0A
L/R=7ms
L/R=15ms
4
FTR-F1 Series
■■ Dimensions
• Dimensions
FTR-F1A type
FTR-F1C type
* Dimensions of the terminals do not include thickness of pre-solder.
• Schematics
(BOTTOM VIEW)
FTR-F1A
FTR-F1C
• PC Board Mounting Hole Layout
(BOTTOM VIEW)
FTR-F1A
FTR-F1C
( ): Reference value
Unit: mm
* Tolerance of PC board mounting hole layout : ±0.1 unless otherwise specified.
Cautions
•
•
•
•
All values mentioned in this datasheet are provided under ideal conditions. Please perform the confirmation test
before actual use.
Reflow soldering is prohibited.
Do not use relays in the atmosphere with sulfide gas, chloride gas or nitric oxide. Contact resistance may increase.
Do not use silicon or silicon-containing product or materials near relays. It may cause contact failure.
5
FTR-F1 Series
GENERAL INFORMATION
1. ROHS Compliance
• All relays produced by Fujitsu Components are compliant with RoHS directive 2011/65/EU including amendments.
• Use of Cadmium in electrical contacts is exempted as per Annex III of the RoHS directive 2011/65/EU.
•
Please consider expiry date of exemption. Relays with Cadmium containing contacts are not to be used for
new designs.
All relays are lead-free. Please refer to Lead-Free Status Info for older date codes at:
http://www.fujitsu.com/downloads/MICRO/fcai/relays/lead-free-letter.pdf
Characteristic data is not guaranteed values, but measured values of samples from production line.
•
2. Recommended lead free solder condition
• Lead free solder plating on relay terminals is Sn-3.0Ag-0.5Cu, unless otherwise specified. This material has
been verified to be compatible with PbSn assembly process.
• Recommended solder for assembly: Sn-3.0Ag-0.5Cu.
Flow Solder Condition:
Pre-Heating: maximum 120˚C
within 90 sec.
Soldering:
dip within 5 sec. at
255˚C ± 5˚C solder bath
Relay must be cooled by air immediately
after soldering
Solder by Soldering Iron:
Soldering Iron: 30-60W
Temperature: maximum 350-360˚C
Duration:
maximum 3 sec.
We highly recommend that you confirm your actual solder conditions
3. Moisture Sensitivity
• Moisture Sensitivity Level standard is not applicable to electromechanical relays, unless otherwise indicated.
4. Tin Whiskers
• Dipped SnAgCu solder is known as presenting a low risk to tin whisker development. No considerable
length whisker was found by our in house test.
6
FTR-F1 Series
Fujitsu Components International Headquarter Offices
Japan
FUJITSU COMPONENT LIMITED
Shinagawa Seaside Park Tower 19F,
12-4, Higashi-shinagawa 4-chome, Shinagawa-ku,
Tokyo,140-0002, Japan
Tel: (81-3) 3450-1682
Fax: (81-3) 3474-2385
Email: fcl-contact@cs.jp.fujitsu.com
Web: www.fujitsu.com/jp/fcl/
Asia Pacific
FUJITSU COMPONENTS ASIA, LTD.
102E Pasir Panjang Road
#01-01 Citilink Warehouse Complex
Singapore 118529
Tel: (65) 6375-8560
Fax: (65) 6273-3021
Email: fcal@sg.fujitsu.com
Web: www.fujitsu.com/sg/products/devices/components
North and South America
FUJITSU COMPONENTS AMERICA, INC
2290 North First Street, Suite 212
San Jose, CA 95131, USA
Tel: (1-408) 745-4900
Fax: (1-408) 745-4970
Email: components@us.fujitsu.com
Web: us.fujitsu.com/components
China
FUJITSU ELECTRONIC COMPONENTS (SHANGHAI) CO., LTD.
Unit 4306, InterContinental Center
100 Yu Tong Road, Shanghai 200070,
China
Tel: (86-21) 3253 0998
Fax: (86-21) 3253 0997
Email: fcal@sg.fujitsu.com
Web: www.fujitsu.com/sg/products/devices/components
Europe
FUJITSU COMPONENTS EUROPE B.V.
Diamantlaan 25
2132 WV Hoofddorp
Netherlands
Tel: (31-23) 5560910
Fax: (31-23) 5560950
Email: info@fceu.fujitsu.com
Web: www.fujitsu.com/uk/components
Hong Kong
FUJITSU COMPONENTS HONG KONG CO., LTD
Unit 506, Inter-Continental Plaza
No.94 Granville Road, Tsim Sha Tsui, Kowloon,
Hong Kong
Tel: (852) 2881-8495
Tex: (852) 2894-9512
Email: fcal@sg.fujitsu.com
Web: www.fujitsu.com/sg/products/devices/components/
Korea
FUJITSU COMPONENTS KOREA LIMITED
Alpha Tower #403, 645 Sampyeong-dong,
Bundang-gu, Seongnam-si, Gyeonggi-do,
13524 Korea
Tel: (82) 31-708-7108
Fax: (82) 31-709-7108
Email: fcal@sg.fujitsu.com
www.fujitsu.com/sg/products/devices/components/
©2018 Fujitsu Components Europe B.V. All rights reserved. All trademarks or registered trademarks are the property of their respective owners.
The contents, data and information in this datasheet are provided by Fujitsu Component Ltd. as a service only to its user and only for general
information purposes.
The use of the contents, data and information provided in this datasheet is at the users’ own risk.
Fujitsu has assembled this datasheet with care and will endeavor to keep the contents, data and information correct, accurate, comprehensive,
complete and up to date.
Fujitsu Components Europe B.V. and affiliated companies do however not accept any responsibility or liability on their behalf, nor on behalf of its
employees, for any loss or damage, direct, indirect or consequential, with respect to this datasheet, its contents, data, and information and related
graphics and the correctness, reliability, accuracy, comprehensiveness, usefulness, availability and completeness thereof.
Nor do Fujitsu Components Europe B.V. and affiliated companies accept on their behalf, nor on behalf of its employees, any responsibility or liability
for any representation or warrant of any kind, express or implied, including warranties of any kind for merchantability or fitness for particular use,
with respect to these datasheets, its contents, data, information and related graphics and the correctness, reliability, accuracy, comprehensiveness,
usefulness, availability and completeness thereof. Rev. July 17th, 2018
7