0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1120-0469

1120-0469

  • 厂商:

    GAMEWELL-FCI

  • 封装:

  • 描述:

    1120-0469 - System Control Unit - Gamewell-FCI by Honeywell

  • 数据手册
  • 价格&库存
1120-0469 数据手册
7200 SERIES SCU SYSTEM CONTROL UNIT DESCRIPTION The System Control Unit (SCU) contains the system processor, system operating software and the system configuration memory to coordinate “distributive processing” of all 7200 Series system operations. The SCU functions as the system information and control center, processing all messages from any cable connected unit, including two degrade alarm (ADAC®) modes to ensure system survivability. It mounts in the top position in the cabinet. The System Control Unit also provides two (2) notification appliance circuits, Class A or B, Style Z or Y, remote city outputs (city box or polarity reversal), and alarm and trouble actuated relay contacts. A pluggable terminal block is provided with the SCU for the connection of all field wiring. This block will accommodate wire sizes up to 12 AWG. The SCU is a one and one half size unit. The SCU also includes a Programming/Diagnostic Center with a two-character 7-segment digital display providing system operation, programming and internal trouble shooting features. Three front panel user switches are provided for system “RESET/LAMP TEST”, “SILENCE”, and “ACKNOWLEDGE”. Additional switches include “PROGRAMMING”, and “NORMAL/OFF” switches for “MUNICIPAL” circuits, control of “NOTIFICATION (CIRCUIT) 1” and “NOTIFICATION (CIRCUIT) 2”. LEDs located on the System Control Unit include: • • • • • • Red Yellow Yellow Yellow Yellow Yellow “ALARM” “SUPERVISORY” “SYSTEM TROUBLE” “TROUBLE NOTIFICATION 1” “TROUBLE NOTIFICATION 2” “GROUND FAULT” • • • • • Yellow Yellow Yellow Yellow Yellow “TROUBLE MUNICIPAL” “SIGNAL SILENCE” “PROGRAM 1” “PROGRAM 2” “DEGRADE” TECHNICAL AND ORDERING INFORMATION Part No. 1120-0469 Model SCU Supervisory Current .050 amp. Alarm Current .260 amp. Description System Control Unit ADAC® is a registered trade mark of Fire Control Instruments, Inc. Specifications are provided for information only and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice. © 1997 All Rights Reserved 301 2nd Ave Waltham, MA 02451-1133 USA TEL: (781) 487-0088 FAX: (781) 370-4132 9020-0292/Ver. 1.3
1120-0469 价格&库存

很抱歉,暂时无法提供与“1120-0469”相匹配的价格&库存,您可以联系我们找货

免费人工找货