1400

1400

  • 厂商:

    GAMEWELL-FCI

  • 封装:

  • 描述:

    1400 - Ionization detector - Gamewell-FCI by Honeywell

  • 数据手册
  • 价格&库存
1400 数据手册
1400 System Sensor Ionization Smoke Detector Description The System Sensor 1400 dual-chamber ionization smoke detector is specifically designed to meet the performance requirements of fire detection/alarm systems. This detector uses a state-of-the-art unipolar sensing chamber. The detector is designed to provide open area detection and is compatible with FCI fire alarm control panels. The detector operation and sensitivity can be tested in place. The detector has an LED which flashes every ten seconds indicating that power is being applied to the detector. The LED lights steadily when the detector is in alarm. A remote LED annunciator is available as an optional accessory. The 1400 detector includes a tamper-resistant feature that, when used, prevents removal of the detector without the use of a tool. Sensitivity testing is performed by inserting a tool into the recessed test switch opening. Field metering of detector sensitivity may be performed with the aid of a voltmeter and test kit MOD 400R. 1400 Features • Unique dual unipolar sensor provides exceptional stability. • Built-in tamper-resistant feature. • Built-in test switch. • Built-in visual alarm indicator. • Remote LED option. • Compatible with FCI control panels. • Field metering of detector sensitivity. • Removable insect screen and cover for field cleaning. • Sealed against dirt, insects, and back pressure. • Insect-resistant screening (.020"/.508mm openings). • Convenient terminal strip wiring. Specifications Nominal sensitivity Operating voltage Standby current Operating temperature 1.5%/ft. obscuration 8.5 - 35 VDC (24 VDC nominal) 100 µA maximum 32° to 120° F (0° to 49° C) Operating humidity 10 % - 93 % relative humidity Air velocity 1,200 ft. per minute maximum Altitude 10,000 feet Construction Off-white flame retardant plastic Diameter 5.5 inches (14 cm) Height 3.12 inches (8.0 cm) Weight 0.7 lb (310 gm) Note: Alarm current is limited by the control panel initiating device circuit. An ISO 9001-2000 Company Ordering Information Part Number 1400 Description Ionization detector GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2006 Gamewell-FCI. All rights reserved. www.gamewell-fci.com 9020-0586 Rev. B page 1 of 2 Mounting • On a 4-inch square box with plaster ring and FCI supplied mounting bracket kit. Minimum depth 1.5 inches. • On a 3.5 or 4-inch octagonal box. Minimum depth 1.5 inches. • Directly to ceiling using plastic screw anchors. Refer to N.F.P.A. 72, Chapter 2-3. “Smoke Sensing Fire Detectors” for spacing, location of detectors and other guidelines. Views Showing Position of Test Magnet Installation Line up the arrows on the detector with the arrows on the mounting bracket. Turn the detector clockwise until the detector clicks into place. To use the tamper-proof feature, break the smaller tab at the scribed line in the tamper-proof tab located on the detector mounting bracket. Install the detector. To remove the detector from the bracket when using the tamper-proof feature, insert the blade of a small screwdriver into the hole on the side of the base and push the plastic lever away from the detector head. Turn the detector counterclockwise for removal. NOTE: The decorative ring must be removed in order to remove a head after it has been made tamper-proof. NOTE: The number of two-wire smoke detectors which can be accommodated per zone varies with different control panels. Consult the control panel instruction manual to determine the capacity. Testing Detectors may be tested in the following ways: • A. Insert a tool into the test opening in the unit. For the complete procedure, refer to the Installation and Maintenance Instructions furnished with each detector. • B. Field metering of detector sensitivity may be performed with the aid of a voltmeter and test kit MOD 400R. For the complete procedure, refer to the Installation and Maintenance Instructions furnished with each detector. Maintenance Cleaning programs should be adapted to the individual environment in conformance with NFPA Standard 72. We recommend, at the least, an annual cleaning of the unit. The detector screen and cover assembly can be removed, revealing the sensing chamber. A vacuum cleaner can be used to remove dust from the screen, cover and sensing chamber. For the complete procedure, refer to the Installation and Maintenance instructions furnished with each detector. WARNING: To prevent detector contamination during construction, smoke detectors must be protected from dust and contamination until area is clean and dust free. See NFPA 72-5-3.7.1.3. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fci.com 9020-0586 Rev. B page 2 of 2

很抱歉,暂时无法提供与“1400”相匹配的价格&库存,您可以联系我们找货

免费人工找货
61400-1
  •  国内价格
  • 20+0.11553
  • 200+0.1074
  • 600+0.09926
  • 3000+0.09112

库存:30

1461400-1
  •  国内价格
  • 1+1.674
  • 10+1.5965

库存:978

LFCN-1400+
  •  国内价格
  • 1+14.52001

库存:44

0430201400
  •  国内价格
  • 1+2.3958
  • 10+2.1978
  • 30+2.1582
  • 100+2.0394

库存:400

DFLU1400-7
    •  国内价格
    • 1+0.8568
    • 10+0.8228
    • 100+0.7412
    • 500+0.7004

    库存:2133

    0430251400
    •  国内价格
    • 1+0.91567
    • 100+0.83605

    库存:4502

    160014-0013
    •  国内价格
    • 1+2.28246
    • 10+2.09538
    • 30+2.05796

    库存:28

    SS-1400S-L2
    •  国内价格
    • 1+0.4123
    • 10+0.3968
    • 100+0.3503
    • 500+0.341

    库存:0

    503149-1400
    •  国内价格
    • 1+1.86689
    • 10+1.71989
    • 30+1.69049
    • 100+1.60229

    库存:25