PIM-SS 数据手册
PIM-SS Features • Ten addressable Class B or five addressable Class A initiating device circuits. • Removable 12 AWG (3.25 mm²) to 18 AWG (0.9 mm²) plug-in terminal blocks. • Use with Gamewell’s IF602, 610, 632, 654 and 658 with SmartScan™ loop card. • Status indicators for each point. • Unused addresses may be disabled. • Rotary address switches. • Class A or Class B operation. • Mount one or two modules in a BB-XP cabinet (optional). • Mount up to six modules on a CHS-6 chassis in a BB-25 cabinet (optional). • Mounting hardware included. Ten-Input Monitor Module Description Gamewell’s SmartScanTM PIM-SS teninput monitor module provides an interface between a control panel and normally open contact devices in intelligent alarm systems such as conventional pull stations and heat detectors. The first address on the PIM-SS is set from 01 to 90 and the remaining modules are automatically assigned to the next nine higher addresses. Provisions are included for disabling a maximum of two unused addresses. SS-M with SS-B6 base The supervised state (normal, open, or short) of the monitored device is sent back to the panel. A common SLC input is used for all modules, and the initiating device loops share a common supervisory supply and ground — otherwise each monitor operates independently from the others. Each PIM-SS module has panel-controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off. Listings Listings and approvals below apply to the PIM-SS Ten-Input Monitor Module. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: file S521. • CSFM approved: file 7300-1288:169. • MEA approved: file 368-01-E Vol. II. Product Line Information PIM-SS: Ten-input monitor module. BB-25: Optional cabinet for up to six modules mounted on CHS-6 chassis (below). Dimensions, DOOR: 24.0" (60.96 cm) wide x 12.632" (32.0852 cm) high, x 1.25" (3.175 cm) deep, hinged at bottom; BACKBOX: 24.0" (60.96 cm) wide x 12.550" (31.877 cm) high x 5.218" (13.2537 cm) deep. CHS-6: Chassis, mounts up to six modules in a BB-25 cabinet. PIM-SS CS-2468 09/01/06 Page 1 of 2 Specifications Standby current: 3.5 mA (SLC current draw with all addresses used; if some addresses are disabled, the standby current decreases). Alarm current: 55 mA (assumes all ten LEDs solid ON). Temperature range: 32°F to 120°F (0°C to 49°C) for UL applications Humidity: 10% to 85% noncondensing for UL applications Dimensions: 6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x 1.25" (31.75 mm) deep. Shipping weight: 1.1 lb. (0.499 kg) including packaging. Mounting options: CHS-6 chassis, BB25 cabinet, or suitably grounded metallic cabinet. Wire gauge: 12 AWG (3.25 mm²) to 18 AWG (0.9 mm²). Power-limited circuits m ust employ type FPL, FPLR, or FPLP cable as required by Article 760 of the NEC. PIM-SS is shipped in Class B position; remove shunt for Class A operation. Maximum IDC wiring resistance: 1500 ohms. Maximum IDC voltage: 12 VDC. Maximum IDC current: 1 mA. FIGURE 1: Typical Initiating Device Circuit Configuration — Class B, Style B. NOTE: Any number of UL-Listed contact closure devices may be used. DO NOT MIX fire alarm initiating and supervisory devices on the same initiating device circuit. Install contact closure devices per manufacturer’s installation instructions. 52347w1.wmf 52347w2.wmf FIGURE 2: Typical Fault-Tolerant Initiating Device Circuit Configuration — Class A, Style D. NOTE: Any number of UL-Listed contact closure devices may be used. DO NOT MIX fire alarm initiating and supervisory devices on the same initiating device circuit. Install contact closure devices per manufacturer’s installation instructions. Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118 www.gamewell-fci.com A Honeywell Company © 2006 Gamewell-FCI Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell-FCI. Page 2 of 2 PIM-SS CS-2468 09/01/06
PIM-SS
1. 物料型号: - 型号为PIM-SS,这是一个十输入监控模块。

2. 器件简介: - PIM-SS模块提供控制面板与智能报警系统中通常开路接触设备(如传统拉杆站和热探测器)之间的接口。

3. 引脚分配: - 模块具有可移除的12 AWG(3.25 mm²)至18 AWG(0.9 mm²)的插入式端子块。

4. 参数特性: - 待机电流:3.5 mA(如果所有地址都使用时的SLC电流消耗;如果有些地址被禁用,待机电流会降低)。 - 报警电流:55 mA(假设所有十个LED常亮)。 - 温度范围:32°F至120°F(0°C至49°C)适用于UL应用。 - 湿度:10%至85%非凝结水适用于UL应用。 - 尺寸:6.8英寸(172.72毫米)高x 5.8英寸(147.32毫米)宽x 1.25英寸(31.75毫米)深。 - 运输重量:1.1磅(0.499公斤),包括包装。 - 端子线规:12 AWG(3.25 mm²)至18 AWG(0.9 mm²)。

5. 功能详解: - 可寻址的10个Class B或5个Class A启动设备电路。 - 每个点都有状态指示器。 - 未使用的地址可以被禁用。 - 旋转地址开关。 - Class A或Class B操作。 - 可以在BB-XP机柜中安装一个或两个模块(可选)。 - 在BB-25机柜中的CHS-6底盘上最多安装六个模块(可选)。 - 包括安装硬件。

6. 应用信息: - 与Gamewell的IF602、610、632、654和658配合SmartScan™回路卡使用。

7. 封装信息: - 可以安装在CHS-6底盘、BB25机柜或适当接地的金属机柜中。 - PIM-SS在出厂时处于Class B位置;移除旁路即可进行Class A操作。 - 电源限制电路必须使用FPL、FPLR或FPLP电缆,如NEC第760条所要求。