    RSS-24MCW-FR - Single & Multi-Candela - Gamewell-FCI by Honeywell

  • 数据手册
  • 价格&库存
RSS-24MCW-FR 数据手册
Cooper-Wheelock RSS-RSSP Series Single & Multi-Candela RSS Series Strobes, RSSP Series Strobe Plates Description The Cooper-Wheelock Series RSS Strobes and RSSP Strobe Plates have low current draw while maintaining outstanding performance, reliability, and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall, or ceiling mount applications. Strobe options for wall mount modules include 15/75, or the MCW multi-candela strobe with field selectable settings of 15/30/75/100 cd, or the high intensity MCWH strobe with field selectable 135/185 cd settings. Ceiling mount models include the MCC multi-candela ceiling strobe with field selectable settings of 15/30/75/95 cd, or the high intensity MCCH strobe with field selectable 115/177 cd settings. All models may be synchronized with the CooperWheelock SM or DSM Sync Modules. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. CooperWheelock’s synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. Cooper-Wheelock’s Series RSS Strobes employ an Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4” square, 100 mm European backbox or to the SHBB surface back box. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional 0.65” of trim for the appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-candela Strobe Plate is a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitone devices, or speakers and easily mounts to standard 4” backboxes or for surface mount use with the CooperWheelock SBL2 surface backbox. RSS Series RSS Series RSS Series Multi-Candela Indicator (bottom of lens) Features • Approvals include: - UL Standard 1971 - California State Fire Marshal (CSFM) - New York City (MEA) - Factory Mutual (FM) ADA/NFPA/UFC/ANSI compliant. Wall mounted models are available with field selectable multi-candela settings of 15, 30, 75, or 110 cd with high intensity models settable to 135 or 185 cd. Ceiling mounted models are available with field selectable multi-candela settings of 15, 30, 75, or 95 cd with high intensity models set to 115 or 177 cd. Single candela models provide 15/75 cd. Strobes flash once per second over the regulated voltage range. • • • • • • 12 & 24 VDC models with wide UL “regulated volt age range” using filtered DC or unfiltered FWR input volt age. • Synchronize with SM or DSM sychronization modules. • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires. An ISO 9000-2000 Company GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 ©2006 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. Gamewell-FCI. All rights reserved. www.gamewell-fci.com 9020-0575 Rev. B page 1 of 4 General Notes • Strobes are designed to flash at one flash per second minimum over Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of one to two flashes per second and ADA guidelines specify a flash rate of one to three flashes per second. • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). • “Regulated Voltage Range” is the newest terminology used by UL to identify the voltage range. Prior to this, UL used the term “Listed Voltage Range”. Table 1: Average RMS Current* RSS/ RSSP 24VDC Models 1575 cd 16 VDC 24 VDC 33 VDC RSS/ RSSP 24 VDC Models 121575W 8 VDC 12 VDC 17.5 VDC Table 2: Audible/Speakers for RSSP Strobe Plate Product Multitone Appliances Horns Motor Bells Speakers Series AMT, MT AH, NH, HS MB-G6/G10 ET-1010/1080, E70, ET70 Chimes CH70 SM-12/24-R DSM-12/24-R 6369 6374 24 24 Model Number SYNC Modules Order Code Input Voltage (VDC) Average Mean Current @ 24 VDC 0.028 0.035 W W Mounting Options RSS/RSSP - Wall Mount 241575W 15 cd 30 cd 75 cd 110 cd 0.062 0.102 0.192 0.265 135 cd 0.300 185 cd 0.420 0.068 15 cd 24MCW 24MCWH RSS - Ceiling Mount 24MCC 24MCCH 30 cd 75 cd 95 cd 115 cd 177 cd 0.420 0.101 0.112 0.211 0.292 0.300 0.064 0.041 0.062 0.116 0.155 0.195 0.270 0.045 0.072 0.128 0.171 0.195 0.270 0.047 0.032 0.047 0.081 0.107 0.145 0.190 0.035 0.052 0.089 0.118 0.145 0.190 RSS/ RSSP Wall Mount * Average RMS Current is per UL average RMS method and Average Mean Current is per UL average mean method. 12 volt models use Average Mean Current. For rated inrush and peak current across the UL Listed voltage range for both filtered DC and unfiltered Vrms (FWR), see installation instructions. 0.336 0.179 0.136 SM Sync Module is rated for 3.0 amperes @ 24 VDC DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is 20. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fci.com 9020-0575 Rev. B page 2 of 4 WIRING DIAGRAMS SERIES RSS/RSSP APPLIANCES NON-SYNCHRONIZED FROM PRECEDING APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP + - + - TO NEXT APPLIANCE OR EOLR SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F A C P STROBE NAC CIRCUIT + STROBE - STROBE RSS + AUDIBLE EOLR - AUDIBLE RSS +SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT STROBE NAC CIRCUIT OUT SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MUTIPLE DSM MODULES DSM #1 STROBE NAC CIRCUIT + SYNC - SYNC DSM + SYNC - SYNC + OUT 1 + IN 1 MINUS 1 RSS RSS RSS RSS RSS F A C P STROBE NAC CIRCUIT DSM #2 + SYNC - SYNC F A C P STROBE NAC CIRCUIT RETURN RSS RSS + AUDIBLE - AUDIBLE MINUS 2 + IN 2 + OUT 2 DSM #3 RSS RSS RSS STROBE NAC CIRCUIT + SYNC - SYNC RSS RSS DSM INTERCONNECTING WIRING SHOWN. MAXIUMUM OF TWENTY (20) MODULES STROBE/PLATE ASSEMBLY FROM PRECEDING APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP STROBE/PLATE ASSEMBLY FROM PRECEDING APPLIANCE OR FACP AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON + - + - TO NEXT APPLIANCE OR EOLR + AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY - + - TO NEXT APPLIANCE OR EOLR TO NEXT STROBE OR EOLR +STROBE +APPLIANCE FROM PRECEDING APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP + +STROBE + +APPLIANCE GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fci.com 9020-0575 Rev. B page 3 of 4 Architects and Engineers Specifications The visual notification appliances shall be Cooper-Wheelock Series RS strobe appliances or approved equals. The Series RSS shall be Listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series RSS shall be of low current design. Where multi-candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL Standard 1971 at: 15, 30, 75, and 110 cd, or 135/185 cd for wall mount, or 15, 30, 75, and 95cd or 115/177 cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 cd UL Standard 1971 Listing with 75 cd on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Cooper-Wheelock’s SM and DSM Sync Modules. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate, (i.e. contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series RSS Strobe appliances shall incorporate a patented universal mounting plate that allows mounting on a single-gang, double-gang, 4-inch square, 100 mm European type backbox, or the SHBB surface backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the appliance an attractive appearance. The appliance shall not have any mounting holes or screw heads visible when the installation is complete. The Series RSSP Multi-Candela or single candela Strobe Plate shall be mounted on either a standard 4-inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. Specifications and Ordering Information Model RSS-24MCW-FR RSS=241575W-FR RSS-121575W-FR RSS-24MCC-FW RSS-24MCCR-FW RSS-24MCCH-FW RSS-24MCCR-FW RSS-24MCWH-FR RSSWP-2475W-FR RSSP-121575W-FR RSSP-24MCW-FR RSSP-241575W-FR RSSP-24MCWH-FR Order Wall Ceiling NonCode Mount Mount Sync 9400 7471 7476 3158 3159 3461 3463 3465 9013 7798 9402 7793 9482 X X X — — — — X X X X X X — — — — — — — X X X X X X X X X X X X X X X X X Sync w/ SM or DSM Strobe Candela 15/30/75/110 15 (75 on Axis) 15 (75 on Axis) 15/30/75/95 15/30/75/95 115/177 115/177 135/185 75 @ -31°F 15 (75 on Axis) 15/30/75/110 15 (75 on Axis) 135/185 24 VDC X 12 VDC # Model # Model Square Color Color or Round Red White UL MEA CSFM FM BFP X X X X X X X X X X X X X X — X X X X X X — X — X — — X — — — — — X — — X X X — — — — X X X X x X — — — X X X X — — — — Square Square Square Square Round Square Round Square Square Square Square Square Square X X X X X X x X X X X X X X X X * * * * * X X X X * X X X * * * * * X X X X * X X X * * * * * X X X X * X X X * * * * * * X X X * # Models are available in either red or white. * PENDING GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 www.gamewell-fci.com 9020-0575 Rev. B page 4 of 4
RSS-24MCW-FR 价格&库存

很抱歉,暂时无法提供与“RSS-24MCW-FR”相匹配的价格&库存,您可以联系我们找货

免费人工找货