0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CLP0212FPEX5Z03A

CLP0212FPEX5Z03A

  • 厂商:

    GE

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 12V 200W

  • 数据手册
  • 价格&库存
CLP0212FPEX5Z03A 数据手册
GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Features  Compact size 50.8 mm x 101.6 mm x 36.1 mm (2 in x 4 in x 1.4 in) with density of 18W/in3  Universal AC Input Range (90 – 264VAC)  Output voltage of 12V (adjustable ±5%)  Maximum output current of 16.7A@ 12Vout (200W)  Standby output of 5V or 3.3V @ 0.25A  High efficiency with 80 PLUS® Gold Certification  Full load capability at 50ºC and 1m/s (200LFM) airflow with derating at higher temperatures or lower airflows  Remote ON/OFF  Output overcurrent protection (non-latching)  Overtemperature protection  Output overvoltage protection  Up to 12ms of holdup time  Parallellable with current sharing Applications  Active power factor corrected input  Telecommunications equipment   Conducted EMI - meets CISPR22 (EN55022) and FCC Class A requirements Embedded Computing  Compliant to RoHS II EU “Directive 2011/65/EU”  Storage Systems   Industrial equipment UL and cUL approved to UL/CSA60950-1, TUV (EN60950-1), CE Mark (for LVD) and CB Report available  ISO** 9001 and ISO 14001 certified manufacturing facilities  Description In a small 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energy efficiency. W i t h i t s s m a l l s i z e , t he CLP series is specifically designed to handle power challenges associated with tight space and low airflow. Offering a leading 18W/in3 power density in a 1U high, fan- less form factor, the CLP series addresses a broad range of applications in new products from communications, computing and data storage original equipment manufacturers (OEMs). It delivers greater than 90 percent typical power efficiency and full load output at +50˚C (122˚F) with higher temperature operation possible at derated output. The CLP series utilizes a unique design approach at this power level, leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits. Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP). * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards ‡ February 14, 2017 ©2017 General Electric Company. All rights reserved. GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous All 90 264 Vac For up to 10 seconds max. Input Voltage – Continuous – CATV Powering trapezoidal waveform (Note: Output power is limited to 100W) All 90 275 Vac All 75 130 VRMS Operating Ambient Temperature All -25 70 °C CLP0212FPEX5Z01A, C -40‡ 85* °C CLP0212FPEX5Z02A CLP0212FPEX5Z03A, C -40‡ 85* °C (in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 65W) CLP0212FPEX5Z02A -40 55† °C (in sealed enclosure applications with thermally conductive pad to enclosure, PO,max = 110W) CLP0212FPEX5Z03A, C -40 55† °C Storage Temperature All -40 85 °C Humidity (non-condensing) All 5 95 % Altitude All 5000 m (see Thermal Considerations section) ‡ Startup at -40ºC is limited to 80% of maximum load (160W) for all versions, except the CLP0212FPEX5Z02A which can start up at full load. * Unit is capable of operation up to 85ºC ambient for brief periods of time provided humidity is kept below 40%. Sustained operation at 85ºC when input voltage is above 230VAC and output power loading is at or near the maximum rated value can degrade reliability of the product. † Ambient temperature outside the sealed enclosure containing the power supply. Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 264 Vac Input Source Frequency All All versions except CLP0212FPEX5Z02A CLP0212FPEX5Z02A All 47 50/60 63 Hz Input Current (VIN = 90Vac) Input Power Factor ARMS ARMS A Peak 0.95 Inrush Transient Current (VIN = 264Vac, Tamb = 25ºC) All 100 Leakage Current to earth ground (VIN = 264Vac) All 2 Output Voltage Setpoint Output Voltage Tolerance (due to set point, temperature variations, load and line regulation) Output Voltage Adjustment Range All Output Remote Sense Range All Output Load Regulation Output Line Regulation Output Ripple and Noise – measured with 0.1µF ceramic capacitor in parallel with 10µF tantalum capacitor, at 25°C1 Peak-to-peak (20MHz Bandwidth) Dynamic Load Response – 50% to 75% load transient, 0.1A/µs slew rate Output voltage deviation Settling Time Output Current Output Current Output Current Limit Inception 1 4 1.6 12 mA Vdc All -2 2 All 11.4 12.6 Vdc 250 mVdc All 1.5 %Vout All 0.5 %Vout All 180 mV p-p All All All versions except CLP0212FPEX5Z02A CLP0212FPEX5Z02A 5% 500 % µs 16.7 Adc 0 0 All 8.34 115 % Adc % IO,max Output ripple is 300mV p-p maximum at -40°C. To reduce further, additional external capacitance needed. February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 2 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Electrical Specifications (cont.) Parameter Device Maximum Output Capacitance Min Standby Output Voltage All CLP0212FPXX5Z01A CLP0212FPEX5Z01A, C CLP0212FPXX3Z01A Standby Output Current All Typ Max Unit 5000 µF 5 Vdc 3.3 Vdc 0.25 Adc Efficiency: VIN = 230Vac, 20% load All except ..Z02A 86.8 % 50% load All except ..Z02A 91.1 % 100% load All except ..Z02A 89.5 % VIN = 115Vac, 20% load All except ..Z02A 89.2 % 50% load All except ..Z02A 90.3 % 100% load All except ..Z02A 87.1 % Holdup Time – VIN = 115Vac, 100% load2 65W load for CLP0212FPEX5Z02A All except ..Z02A CLP0212FPEX5Z02A 10 32 ms VIN = 230Vac, 100% load 65W load for CLP0212FPEX5Z02A All except ..Z02A CLP0212FPEX5Z02A 10 32 ms Isolation Specifications Parameter Device Max Unit All 3000 Vac Input to safety ground All 1500 Vac Outputs to safety ground All 50 Vac Isolation Voltage – Input to output Min General Specifications Parameter Device Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case 3 (VIN=230Vac, Io = 16.7A, TA = 40ºC, airflow 200LFM, 90% confidence) Weight Symbol Typ. Unit FIT 1,011.9 109/Hours MTBF 988,276 Hours 185 6.5 g oz. All All Feature Specifications Parameter Device Min Typ Max Unit On/Off Signal Interface – signal referenced to GND Logic Low (Power Supply ON) Input Low Current All 7 mA Input Low Voltage All 1 V Input High Current All 600 µA Input Voltage All 5.5 V 50 ms Logic High (Power Supply OFF) 2 Delay from ON/OFF being enabled to start of output voltage rise All Output Voltage Rise Time (from 10 to 90% of final value) All 5 ms Delay from Input being applied to standby output being in regulation All 12 ms Delay from Input being applied to all outputs being in regulation All 30 ms Output Overvoltage Protection (for main output currents above 0.1A) All 13.8 18 Vdc Holdup time is reduced at cold temperatures February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 3 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Feature Specifications (cont.) Parameter Device Min Typ Max Unit Input Undervoltage lockout3 Turn-on Threshold (100% load) All 86 Vac Turn-off Threshold (100% load) All 82 Vac DC OK – open collector, High when output available Sink Current All 4 mA Maximum Collector Voltage All 12 V Environmental Specifications Parameter Device Specification Conducted Emissions All CISPR22 (EN55022) Class A with 3dB margin Input Harmonics All EN61000-3-2 ESD All IEC 61000-4-2, Level 3 Radiated Immunity All IEC 61000-4-3, Level 2* Electrical Fast Transient Common Mode All IEC 61000-4-4, Level 3 Surge Immunity All IEC 61000-4-5, Level 3 Conducted RF Immunity All IEC 61000-4-6, Level 3 Voltage Dips All EN61000 4.11, Level 3, Class B, C Operating Shock All Three shocks, 15G peak, 11ms sine wave, two axes Non-Operating Shock All Three shocks, 50G peak, 11ms sine wave, two axes Operating and Non-Operating Vibration All 5 – 9Hz, 0.5” double amplitude, 2G Peak, 0.5 oct./min., 2 cycles 9-500Hz, 4G pk-pk, 0.5 oct/min., 2 cycles Shock and Vibration * Radiated immunity is met when the power supply is tested in a suitable enclosure. 3 The undervoltage lockout thresholds vary with output load current level – decreasing as the load goes down February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 4 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Characteristic Curves The following figures provide typical characteristics for CLP0212 power supply 20 94 OUTPUT CURRENT, Io (A) 92 EFFICIENCY,  (%) 90 88 Vin=115VAC 86 Vin=230VAC 84 82 15 2m/s (400LFM) 10 0.5m/s (100LFM) 5 1m/s (200LFM) NC 80 0 2 4 6 8 10 12 14 16 0 18 30 35 OUTPUT LOAD, A OUTPUT VOLTAGE VO (V) (100mV/div) IO (A) (10Adiv) TIME, t (10ms/div) INPUT VOLTAGE VIN (V) (200V/div) VO (V) (2V/div) VO (V) (2V/div) February 14, 2017 55 60 65 70 TIME, t (5ms /div) TIME, t (10ms/div) Figure 5. Typical Start-up (VIN = 115Vac). 50 Figure 4. Transient Response to Dynamic Load Change from 50% to 100% at Vin = 230Vac. OUTPUT VOLTAGE INPUT VOLTAGE VIN (V) (200V/div) OUTPUT VOLTAGE Figure 3. Typical output ripple and noise (VIN = 230Vac, 100% load ). 45 Figure 2. Derating Output Current versus Ambient Temperature and Airflow. Data shown for 115VAC in, at 230VAC in derating is the same or better. For derating at other input voltages, consult the GE Technical representative. OUTPUT CURRENT, VO (V) (50mV/div) OUTPUT VOLTAGE Figure 1. Power Supply Efficiency versus Output Current. 40 AMBIENT TEMPERATURE, TA OC TIME, t (10ms/div) Figure 6. Typical Start-up (VIN = 230Vac) ©2017 General Electric Company. All rights reserved. Page 5 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Characteristic Curves (cont.) INPUT VOLTAGE VIN (V) (200V/div) VO(V) (2V/div) VIN (V) (200V/div) VO(V) (2V/div) OUTPUT VOLTAGE INPUT VOLTAGE OUTPUT VOLTAGE The following figures provide typical characteristics for CLP0212 power supply TIME, t (10ms/div) Figure 7. Typical Hold-up waveforms (VIN = 115V, 100% load). February 14, 2017 TIME, t (10ms/div) Figure 8. Typical Hold-up waveforms (VIN = 230V, 100% load). ©2017 General Electric Company. All rights reserved. Page 6 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Safety Considerations Output Voltage Adjustment The CLP0212 power supply is intended for inclusion in other equipment and the installer must ensure that it is in compliance with all the requirements of the end application. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand-alone product. The power supply meets Class 1, IEC60950, EN60950, with the following deviations: Nemko. UL 60950 (Recognized Component) C-UL (Canadian Approval by UL). Potentiometer Feature Descriptions Standby Power Supply Fig. 10. Diagram showing location of the potentiometer used to adjust the power supply output voltage. A standby output in the CLP0212 power supply of either 3.3 or 5V, comes on when AC input in the operating range is applied. In the Z02A and Z03A versions of the power supply, the standby output is not accessible. The output voltage can be adjusted between 11.4V and 12.6V using a potentiometer on the power supply. See Fig. 10 for a diagram showing location of the potentiometer. Remote Sense Remote On/Off All versions of the CLP0212 power supply except the Z02A and Z03A versions feature a TTL-compatible On/Off control input. The power supply turns ON when the On/Off input goes low, and turns OFF when the input goes high. Note that if the On/Off pin is left unconnected, the power supply main output remains off. Figure 9 shows the circuit configuration for using the On/Off pin. Either a suitable semiconductor device such as a BJT or FET or a mechanical switch can be used to turn the power supply On and Off. The switch must be capable of handling the On/Off pin current which may be up to 6mA when closed. The switch On voltage drop must also be sufficiently small so that the photo diode inside the power supply is turned ON when the external switch is ON. Note that the standby output voltage could be either 3.3V or 5V depending on the CLP0212 power supply variant selected. If no On/Off control is desired, the On/Off pin can be externally connected to the COM pin and the power supply will automatically turn ON when AC input is within range. CLP POWER SUPPLY STANDBY OUTPUT 1 Overcurrent Protection To provide protection in a fault condition (output overload), the power supply is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters hiccup mode. The power supply operates normally once the output current is brought back into its specified range. Overvoltage Protection Overvoltage protection is a feature of the CLP0212 power supply that protects both the load and the power supply from an output overvoltage condition. When an overvoltage occurs, the power supply shuts down and goes into hiccup mode until the overvoltage condition is removed. It is not necessary to recycle the input to restart the power supply when this protection is activated. Overtemperature Protection 1K 2 4 5 3.65K The power supply has both positive and negative remote sense connections that can be connected to the positive and negative rails of the main output near the load. Care should be taken in routing the sense lines to ensure that noise is not picked up or that additional filtering elements that affect the stability of the power supply are not used. The power supply will operate without the remote sense connections being made, however if remote sense near the load is not used it is recommended that the remote sense lines be connected directly to the main output terminals. 2 ON/OFF 1 SWITCH COM The CLP0212 also features overtemperature protection in order to provide additional protection in a fault condition. The power supply is equipped with a thermal shutdown circuit which detects excessive internal temperatures and shuts the unit down. Once the power supply goes into overtemperature shutdown, it will cool before attempting to restart. The overtemperature protection circuit will typically activate when the unit is operated at 200W output with an ambient temperature of 60ºC and 1m/s (200LFM) airflow. Fig. 9. Schematic showing ON/OFF circuitry. February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 7 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Input Undervoltage Lockout At input voltages below the input undervoltage lockout limit, power supply operation is disabled. The power supply will begin to operate at an input voltage above the undervoltage lockout turn-on threshold. Note that the undervoltage lockout limits are load dependent and the power supply turns ON and can operate at much lower input voltage levels when at light or no load. DC OK The CLP0212 provides a DC OK signal that indicates when the output has come up and is in regulation. This is an opencollector type signal that goes high when the output is available and within regulation. Fig. 11. Preferred airflow direction for cooling. Power Good LED A green LED (located next to HDR3) illuminates when the main output voltage is above 10V. Paralleling/Load Share This power supply can be paralleled to provide larger load currents than can be delivered from a single power supply. Up to four power supplies may be paralleled. Paralleling is accomplished by connecting the Current Share signals of multiple power supplies together. At load current levels above 20%, the output currents of multiple power supplies will be within ±5% of the full load value. Operation In a Sealed Enclosure The CLP0212 power supply can also be operated in a sealed enclosure provided proper means for removing heat from the power supply are used. Figure 12 shows an arrangement where a thermally conductive pad is used to transfer heat from the bottom of the power supply into the enclosure. Under such conditions, the power supply is capable of reduced power operation as shown in Table 1. Note that the Ambient Temperature shown in Table 1 is that outside the sealed enclosure, the CLP0212 may see higher ambient temperatures. If remote sense is used when paralleling is employed, the remote sense connection points should be common to both power supplies. For applications where redundancy among paralleled power supplies is desired, ORing diodes or other active ORing circuitry needs to be connected in series with each output. Enclosure Wall Thermal Considerations The power supply can be operated in a variety of thermal environments; however sufficient cooling should be provided to ensure reliable operation. Considerations include ambient temperature, airflow, power supply dissipation and the need for increased reliability. A reduction in the operating temperature of the power supply will result in increased reliability. The thermal data presented here is based on measurements taken in a wind tunnel. Heat Transfer via Convection Thermally Conductive Pad Fig. 12. Example arrangement of the CLP0212 for sealed enclosure applications. Table 1. Output Power Capability when the CLP0212 is operated in a sealed enclosure with thermal pad for conduction cooling. Ambient Temperature (ºC) 25 40 55 55 (CATV Powering Input Voltage Waveform) Increased airflow through the power supply enhances the heat transfer via convection. Figure 11 shows the preferred airflow direction. Contact your GE Energy technical representative for derating information in other airflow directions. Note: Under Natural Convection cooling conditions, the maximum load is restricted to 100W as OTP will be triggered at higher loads. Max. Output Power (W) 170 150 110 100 . February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 8 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power EMI performance All CLP0212 power supplies are specified to meet conducted Class A EMI requirements per CISPR 22 (EN55022) with at least 3dB of margin. Results of tests conducted without any external filtering are shown below. These indicate 10dB or better of margin over the Class A limits. CLP0212FPXX5Z01A (120VAC in, 12V @ 180W out, Negative of Output Grounded) CLP0212FPXX5Z01A (208VAC in, 12V @ 180W out, Negative of Output Grounded) February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 9 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power CLP0212FPEX5Z03A (120VAC in, 12V @ 180W out, Negative of Output Grounded) CLP0212FPEX5Z03A (208VAC in, 12V @ 180W out, Negative of Output Grounded) February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 10 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power CLP0212FPEX5Z03A + 2 x 4.7nF “Y” capacitors + 0.47µF “X” capacitors (120VAC in, 12V @ 180W out, Negative of Output Grounded) 90.0 80.0 Amplitude (dBuV) 70.0 Class B Q-P Limits 60.0 50.0 Measured Q-P Data 40.0 30.0 20.0 10.0 0 150.0K 10.0M 1.0M 30.0M Frequency (MHz) CLP0212FPEX5Z03A + 2 x 4.7nF “Y” capacitors + 0.47µF “X” capacitors (208VAC in, 12V @ 180W out, Negative of Output Grounded) 90.0 80.0 Amplitude (dBuV) 70.0 Class B Q-P Limits 60.0 50.0 Measured Q-P Data 40.0 30.0 20.0 10.0 0 150.0K 1.0M 10.0M 30.0M Frequency (MHz) February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 11 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Mechanical Outline (all except CLP0212…Z02A & CLP0212…Z03A, C versions) Dimensions are in millimeters. Tolerances: x.x mm ± 0.5mm [unless otherwise indicated] x.xx mm ± 0.25mm VOUT TOP VIEW NEUTRAL RTN LINE NEUTRAL SIDE VIEW 3D-VIEW February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 12 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Mechanical Outline - CLP0212FPEX5Z02A Dimensions are in millimeters. Tolerances: x.x mm ± 0.5mm [unless otherwise indicated] x.xx mm ± 0.25mm TOP VIEW SIDE VIEW 3D-VIEW February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 13 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Mechanical Outline - CLP0212FPEX5Z03A, C Dimensions are in millimeters. Tolerances: x.x mm ± 0.5mm [unless otherwise indicated] x.xx mm ± 0.25mm VOUT TOP VIEW RTN LINE NEUTRAL SIDE VIEW 3D-VIEW February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 14 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Connector Information Connector Connector on Power Supply Mating Connector AC Input Connector (HDR1) 5-1376382-1 from Tyco or equivalent 1376388-1 from Tyco or equivalent DC Output Connector (HDR2) 39-28-1043 from Molex or equivalent 39-01-2040 from Molex or equivalent Signal Connector (HDR3) 53047-0810 from Molex or equivalent 51021-0800 from Molex or equivalent DC Output Connector (HDR2) Signal Connector (HDR3) Pinout Information AC Input Connector (HDR1) Pin 1 Line Pin 1 VO Pin 1 Current Share Pin 2 Neutral Pin 2 VO Pin 2 +S (Remote Sense +) Pin 3 RTN Pin 3 -S (Remote Sense -) Pin 4 RTN Pin 4 Remote On/Off Pin 5 DC-OK (Output OK) Pin 6 COM (Output Return) Pin 7 COM (Output Return) Pin 8 Standby Output Note: Signal Connector HD3 is not present in the Z02A and Z03A, C versions. February 14, 2017 ©2017 General Electric Company. All rights reserved. Page 15 GE Data Sheet CLP0212 Open Frame Power Supply 90 - 264Vac input; 12Vdc output; 200W Output Power Ordering Information Please contact your GE Sales Representative for pricing, availability and optional features. Table 2. Device Codes Device Code Input Voltage Range Output Voltage Output Current On/Off Control Standby Supply Temperature Range Comcode CLP0212FPXX5Z01A* 90 – 264Vac 12.0Vdc 16.7A Negative Logic 5V@0.25A -25 to 70ºC 150032000 CLP0212FPXX3Z01A* 90 – 264Vac 12.0Vdc 16.7A Negative Logic 3.3V@0.25A -25 to 70ºC 150032001 CLP0212FPEX5Z01A* 90 – 264Vac 12.0Vdc 16.7A Negative Logic 5V@0.25A -40 to 70ºC 150032002 CLP0212FPEX5Z02A* 90 – 264Vac 12.0Vdc 8.34A Absent Not accessible -40 to 70ºC 150032003 CLP0212FPEX5Z03A* 90 – 264Vac 12.0Vdc 16.7A Absent Not accessible -40 to 70ºC 150032004 CLP0212FPXX5Z03A* 90 – 264Vac 12.0Vdc 16.7A Absent Not accessible -25 to 70ºC 150032005 CLP0212FPEX5Z01C 90 – 264Vac 12.0Vdc 16.7A Negative Logic 5V@0.25A -40 to 70ºC 150038518 CLP0212FPEX5Z03C 90 – 264Vac 12.0Vdc 16.7A Absent Not accessible -40 to 70ºC 150038520 * Not recommended for new designs Contact Us For more information, call us at USA/Canada: +1 877 546 3243, or +1 972 244 9288 Asia-Pacific: +86.021.54279977*808 Europe, Middle-East and Africa: +49.89.878067-280 www.gecriticalpower.com GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. February 14, 2017 ©2017 General Electric Company. All International rights reserved. Version 1.39
CLP0212FPEX5Z03A 价格&库存

很抱歉,暂时无法提供与“CLP0212FPEX5Z03A”相匹配的价格&库存,您可以联系我们找货

免费人工找货