GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Features
Compact size 50.8 mm x 101.6 mm x 36.1 mm
(2 in x 4 in x 1.4 in) with density of 18W/in3
Universal AC Input Range (90 – 264VAC)
Output voltage of 12V (adjustable ±5%)
Maximum output current of 16.7A@ 12Vout (200W)
Standby output of 5V or 3.3V @ 0.25A
High efficiency with 80 PLUS® Gold Certification
Full load capability at 50ºC and 1m/s (200LFM) airflow
with derating at higher temperatures or lower airflows
Remote ON/OFF
Output overcurrent protection (non-latching)
Overtemperature protection
Output overvoltage protection
Up to 12ms of holdup time
Parallellable with current sharing
Applications
Active power factor corrected input
Telecommunications equipment
Conducted EMI - meets CISPR22 (EN55022) and FCC
Class A requirements
Embedded Computing
Compliant to RoHS II EU “Directive 2011/65/EU”
Storage Systems
Industrial equipment
UL and cUL approved to UL/CSA60950-1, TUV
(EN60950-1), CE Mark (for LVD) and CB Report available
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
In a small 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energy
efficiency. W i t h i t s s m a l l s i z e , t he CLP series is specifically designed to handle power challenges associated with tight
space and low airflow. Offering a leading 18W/in3 power density in a 1U high, fan- less form factor, the CLP series addresses a
broad range of applications in new products from communications, computing and data storage original equipment
manufacturers (OEMs). It delivers greater than 90 percent typical power efficiency and full load output at +50˚C (122˚F) with
higher temperature operation possible at derated output. The CLP series utilizes a unique design approach at this power level,
leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits.
Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP).
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
‡
February 14, 2017
©2017 General Electric Company. All rights reserved.
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Device
Min
Max
Unit
Input Voltage - Continuous
All
90
264
Vac
For up to 10 seconds max.
Input Voltage – Continuous – CATV Powering trapezoidal waveform
(Note: Output power is limited to 100W)
All
90
275
Vac
All
75
130
VRMS
Operating Ambient Temperature
All
-25
70
°C
CLP0212FPEX5Z01A, C
-40‡
85*
°C
CLP0212FPEX5Z02A
CLP0212FPEX5Z03A, C
-40‡
85*
°C
(in sealed enclosure applications with thermally conductive pad to
enclosure, PO,max = 65W)
CLP0212FPEX5Z02A
-40
55†
°C
(in sealed enclosure applications with thermally conductive pad to
enclosure, PO,max = 110W)
CLP0212FPEX5Z03A, C
-40
55†
°C
Storage Temperature
All
-40
85
°C
Humidity (non-condensing)
All
5
95
%
Altitude
All
5000
m
(see Thermal Considerations section)
‡ Startup at -40ºC is limited to 80% of maximum load (160W) for all versions, except the CLP0212FPEX5Z02A which can start up at full load.
* Unit is capable of operation up to 85ºC ambient for brief periods of time provided humidity is kept below 40%. Sustained operation at 85ºC when
input voltage is above 230VAC and output power loading is at or near the maximum rated value can degrade reliability of the product.
† Ambient temperature outside the sealed enclosure containing the power supply.
Electrical Specifications
Parameter
Device
Min
Typ
Max
Unit
Operating Input Voltage
All
90
115/230
264
Vac
Input Source Frequency
All
All versions except
CLP0212FPEX5Z02A
CLP0212FPEX5Z02A
All
47
50/60
63
Hz
Input Current (VIN = 90Vac)
Input Power Factor
ARMS
ARMS
A Peak
0.95
Inrush Transient Current (VIN = 264Vac, Tamb = 25ºC)
All
100
Leakage Current to earth ground (VIN = 264Vac)
All
2
Output Voltage Setpoint
Output Voltage Tolerance (due to set point, temperature variations,
load and line regulation)
Output Voltage Adjustment Range
All
Output Remote Sense Range
All
Output Load Regulation
Output Line Regulation
Output Ripple and Noise – measured with 0.1µF ceramic capacitor in
parallel with 10µF tantalum capacitor, at 25°C1
Peak-to-peak (20MHz Bandwidth)
Dynamic Load Response – 50% to 75% load transient, 0.1A/µs slew
rate
Output voltage deviation
Settling Time
Output Current
Output Current
Output Current Limit Inception
1
4
1.6
12
mA
Vdc
All
-2
2
All
11.4
12.6
Vdc
250
mVdc
All
1.5
%Vout
All
0.5
%Vout
All
180
mV p-p
All
All
All versions except
CLP0212FPEX5Z02A
CLP0212FPEX5Z02A
5%
500
%
µs
16.7
Adc
0
0
All
8.34
115
%
Adc
% IO,max
Output ripple is 300mV p-p maximum at -40°C. To reduce further, additional external capacitance needed.
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 2
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Electrical Specifications (cont.)
Parameter
Device
Maximum Output Capacitance
Min
Standby Output Voltage
All
CLP0212FPXX5Z01A
CLP0212FPEX5Z01A, C
CLP0212FPXX3Z01A
Standby Output Current
All
Typ
Max
Unit
5000
µF
5
Vdc
3.3
Vdc
0.25
Adc
Efficiency: VIN = 230Vac, 20% load
All except ..Z02A
86.8
%
50% load
All except ..Z02A
91.1
%
100% load
All except ..Z02A
89.5
%
VIN = 115Vac, 20% load
All except ..Z02A
89.2
%
50% load
All except ..Z02A
90.3
%
100% load
All except ..Z02A
87.1
%
Holdup Time – VIN = 115Vac, 100% load2
65W load for CLP0212FPEX5Z02A
All except ..Z02A
CLP0212FPEX5Z02A
10
32
ms
VIN = 230Vac, 100% load
65W load for CLP0212FPEX5Z02A
All except ..Z02A
CLP0212FPEX5Z02A
10
32
ms
Isolation Specifications
Parameter
Device
Max
Unit
All
3000
Vac
Input to safety ground
All
1500
Vac
Outputs to safety ground
All
50
Vac
Isolation Voltage – Input to output
Min
General Specifications
Parameter
Device
Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case
3 (VIN=230Vac, Io = 16.7A, TA = 40ºC, airflow 200LFM, 90% confidence)
Weight
Symbol
Typ.
Unit
FIT
1,011.9
109/Hours
MTBF
988,276
Hours
185
6.5
g
oz.
All
All
Feature Specifications
Parameter
Device
Min
Typ
Max
Unit
On/Off Signal Interface – signal referenced to GND
Logic Low (Power Supply ON)
Input Low Current
All
7
mA
Input Low Voltage
All
1
V
Input High Current
All
600
µA
Input Voltage
All
5.5
V
50
ms
Logic High (Power Supply OFF)
2
Delay from ON/OFF being enabled to start of output voltage rise
All
Output Voltage Rise Time (from 10 to 90% of final value)
All
5
ms
Delay from Input being applied to standby output being in regulation
All
12
ms
Delay from Input being applied to all outputs being in regulation
All
30
ms
Output Overvoltage Protection (for main output currents above 0.1A)
All
13.8
18
Vdc
Holdup time is reduced at cold temperatures
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 3
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Feature Specifications (cont.)
Parameter
Device
Min
Typ
Max
Unit
Input Undervoltage lockout3
Turn-on Threshold (100% load)
All
86
Vac
Turn-off Threshold (100% load)
All
82
Vac
DC OK – open collector, High when output available
Sink Current
All
4
mA
Maximum Collector Voltage
All
12
V
Environmental Specifications
Parameter
Device
Specification
Conducted Emissions
All
CISPR22 (EN55022) Class A with 3dB margin
Input Harmonics
All
EN61000-3-2
ESD
All
IEC 61000-4-2, Level 3
Radiated Immunity
All
IEC 61000-4-3, Level 2*
Electrical Fast Transient Common Mode
All
IEC 61000-4-4, Level 3
Surge Immunity
All
IEC 61000-4-5, Level 3
Conducted RF Immunity
All
IEC 61000-4-6, Level 3
Voltage Dips
All
EN61000 4.11, Level 3, Class B, C
Operating Shock
All
Three shocks, 15G peak, 11ms sine wave, two axes
Non-Operating Shock
All
Three shocks, 50G peak, 11ms sine wave, two axes
Operating and Non-Operating Vibration
All
5 – 9Hz, 0.5” double amplitude, 2G Peak, 0.5 oct./min., 2 cycles
9-500Hz, 4G pk-pk, 0.5 oct/min., 2 cycles
Shock and Vibration
* Radiated immunity is met when the power supply is tested in a suitable enclosure.
3
The undervoltage lockout thresholds vary with output load current level – decreasing as the load goes down
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 4
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Characteristic Curves
The following figures provide typical characteristics for CLP0212 power supply
20
94
OUTPUT CURRENT, Io (A)
92
EFFICIENCY, (%)
90
88
Vin=115VAC
86
Vin=230VAC
84
82
15
2m/s
(400LFM)
10
0.5m/s
(100LFM)
5
1m/s
(200LFM)
NC
80
0
2
4
6
8
10
12
14
16
0
18
30
35
OUTPUT LOAD, A
OUTPUT VOLTAGE
VO (V) (100mV/div)
IO (A) (10Adiv)
TIME, t (10ms/div)
INPUT VOLTAGE
VIN (V) (200V/div)
VO (V) (2V/div)
VO (V) (2V/div)
February 14, 2017
55
60
65
70
TIME, t (5ms /div)
TIME, t (10ms/div)
Figure 5. Typical Start-up (VIN = 115Vac).
50
Figure 4. Transient Response to Dynamic Load Change from
50% to 100% at Vin = 230Vac.
OUTPUT VOLTAGE
INPUT VOLTAGE
VIN (V) (200V/div)
OUTPUT VOLTAGE
Figure 3. Typical output ripple and noise (VIN = 230Vac,
100% load ).
45
Figure 2. Derating Output Current versus Ambient
Temperature and Airflow. Data shown for 115VAC in, at
230VAC in derating is the same or better. For derating at
other input voltages, consult the GE Technical
representative.
OUTPUT CURRENT,
VO (V) (50mV/div)
OUTPUT VOLTAGE
Figure 1. Power Supply Efficiency versus Output Current.
40
AMBIENT TEMPERATURE, TA OC
TIME, t (10ms/div)
Figure 6. Typical Start-up (VIN = 230Vac)
©2017 General Electric Company. All rights reserved.
Page 5
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Characteristic Curves (cont.)
INPUT VOLTAGE
VIN (V) (200V/div)
VO(V) (2V/div)
VIN (V) (200V/div)
VO(V) (2V/div)
OUTPUT VOLTAGE
INPUT VOLTAGE
OUTPUT VOLTAGE
The following figures provide typical characteristics for CLP0212 power supply
TIME, t (10ms/div)
Figure 7. Typical Hold-up waveforms (VIN = 115V, 100%
load).
February 14, 2017
TIME, t (10ms/div)
Figure 8. Typical Hold-up waveforms (VIN = 230V, 100% load).
©2017 General Electric Company. All rights reserved.
Page 6
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Safety Considerations
Output Voltage Adjustment
The CLP0212 power supply is intended for inclusion in other
equipment and the installer must ensure that it is in
compliance with all the requirements of the end application.
This product is only for inclusion by professional installers
within other equipment and must not be operated as a
stand-alone product. The power supply meets Class 1,
IEC60950, EN60950, with the following deviations: Nemko. UL
60950 (Recognized Component) C-UL (Canadian Approval by
UL).
Potentiometer
Feature Descriptions
Standby Power Supply
Fig. 10. Diagram showing location of the potentiometer
used to adjust the power supply output voltage.
A standby output in the CLP0212 power supply of either 3.3
or 5V, comes on when AC input in the operating range is
applied. In the Z02A and Z03A versions of the power supply,
the standby output is not accessible.
The output voltage can be adjusted between 11.4V and 12.6V
using a potentiometer on the power supply. See Fig. 10 for a
diagram showing location of the potentiometer.
Remote Sense
Remote On/Off
All versions of the CLP0212 power supply except the Z02A
and Z03A versions feature a TTL-compatible On/Off control
input. The power supply turns ON when the On/Off input
goes low, and turns OFF when the input goes high. Note
that if the On/Off pin is left unconnected, the power supply
main output remains off.
Figure 9 shows the circuit configuration for using the On/Off
pin. Either a suitable semiconductor device such as a BJT or
FET or a mechanical switch can be used to turn the power
supply On and Off. The switch must be capable of handling
the On/Off pin current which may be up to 6mA when
closed. The switch On voltage drop must also be sufficiently
small so that the photo diode inside the power supply is
turned ON when the external switch is ON.
Note that the standby output voltage could be either 3.3V or
5V depending on the CLP0212 power supply variant
selected. If no On/Off control is desired, the On/Off pin can
be externally connected to the COM pin and the power
supply will automatically turn ON when AC input is within
range.
CLP POWER SUPPLY
STANDBY OUTPUT
1
Overcurrent Protection
To provide protection in a fault condition (output overload), the
power supply is equipped with internal current-limiting
circuitry and can endure current limiting continuously. At the
point of current-limit inception, the unit enters hiccup mode.
The power supply operates normally once the output current is
brought back into its specified range.
Overvoltage Protection
Overvoltage protection is a feature of the CLP0212 power
supply that protects both the load and the power supply from
an output overvoltage condition. When an overvoltage occurs,
the power supply shuts down and goes into hiccup mode until
the overvoltage condition is removed. It is not necessary to
recycle the input to restart the power supply when this
protection is activated.
Overtemperature Protection
1K
2
4
5
3.65K
The power supply has both positive and negative remote
sense connections that can be connected to the positive
and negative rails of the main output near the load. Care
should be taken in routing the sense lines to ensure that
noise is not picked up or that additional filtering elements
that affect the stability of the power supply are not used.
The power supply will operate without the remote sense
connections being made, however if remote sense near the
load is not used it is recommended that the remote sense
lines be connected directly to the main output terminals.
2
ON/OFF
1
SWITCH
COM
The CLP0212 also features overtemperature protection in
order to provide additional protection in a fault condition. The
power supply is equipped with a thermal shutdown circuit
which detects excessive internal temperatures and shuts the
unit down. Once the power supply goes into overtemperature
shutdown, it will cool before attempting to restart. The
overtemperature protection circuit will typically activate when
the unit is operated at 200W output with an ambient
temperature of 60ºC and 1m/s (200LFM) airflow.
Fig. 9. Schematic showing ON/OFF circuitry.
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 7
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout limit,
power supply operation is disabled. The power supply will
begin to operate at an input voltage above the undervoltage
lockout turn-on threshold. Note that the undervoltage lockout
limits are load dependent and the power supply turns ON and
can operate at much lower input voltage levels when at light
or no load.
DC OK
The CLP0212 provides a DC OK signal that indicates when
the output has come up and is in regulation. This is an opencollector type signal that goes high when the output is
available and within regulation.
Fig. 11. Preferred airflow direction for cooling.
Power Good LED
A green LED (located next to HDR3) illuminates when the main
output voltage is above 10V.
Paralleling/Load Share
This power supply can be paralleled to provide larger load
currents than can be delivered from a single power supply. Up
to four power supplies may be paralleled. Paralleling is
accomplished by connecting the Current Share signals of
multiple power supplies together. At load current levels above
20%, the output currents of multiple power supplies will be
within ±5% of the full load value.
Operation In a Sealed Enclosure
The CLP0212 power supply can also be operated in a sealed
enclosure provided proper means for removing heat from the
power supply are used. Figure 12 shows an arrangement
where a thermally conductive pad is used to transfer heat
from the bottom of the power supply into the enclosure. Under
such conditions, the power supply is capable of reduced power
operation as shown in Table 1. Note that the Ambient
Temperature shown in Table 1 is that outside the sealed
enclosure, the CLP0212 may see higher ambient temperatures.
If remote sense is used when paralleling is employed, the
remote sense connection points should be common to both
power supplies.
For applications where redundancy among paralleled power
supplies is desired, ORing diodes or other active ORing circuitry
needs to be connected in series with each output.
Enclosure Wall
Thermal Considerations
The power supply can be operated in a variety of thermal
environments; however sufficient cooling should be provided
to ensure reliable operation.
Considerations include ambient temperature, airflow, power
supply dissipation and the need for increased reliability. A
reduction in the operating temperature of the power supply
will result in increased reliability. The thermal data presented
here is based on measurements taken in a wind tunnel.
Heat Transfer via Convection
Thermally Conductive Pad
Fig. 12. Example arrangement of the CLP0212 for sealed
enclosure applications.
Table 1. Output Power Capability when the CLP0212 is
operated in a sealed enclosure with thermal pad for
conduction cooling.
Ambient Temperature (ºC)
25
40
55
55
(CATV Powering Input
Voltage Waveform)
Increased airflow through the power supply enhances the heat
transfer via convection. Figure 11 shows the preferred airflow
direction. Contact your GE Energy technical representative for
derating information in other airflow directions.
Note: Under Natural Convection cooling conditions, the
maximum load is restricted to 100W as OTP will be triggered
at higher loads.
Max. Output Power (W)
170
150
110
100
.
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 8
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
EMI performance
All CLP0212 power supplies are specified to meet conducted Class A EMI requirements per CISPR 22 (EN55022) with at least 3dB of
margin. Results of tests conducted without any external filtering are shown below. These indicate 10dB or better of margin over
the Class A limits.
CLP0212FPXX5Z01A (120VAC in, 12V @ 180W out, Negative of Output Grounded)
CLP0212FPXX5Z01A (208VAC in, 12V @ 180W out, Negative of Output Grounded)
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 9
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
CLP0212FPEX5Z03A (120VAC in, 12V @ 180W out, Negative of Output Grounded)
CLP0212FPEX5Z03A (208VAC in, 12V @ 180W out, Negative of Output Grounded)
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 10
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
CLP0212FPEX5Z03A + 2 x 4.7nF “Y” capacitors + 0.47µF “X” capacitors (120VAC in, 12V @ 180W out, Negative of
Output Grounded)
90.0
80.0
Amplitude (dBuV)
70.0
Class B Q-P Limits
60.0
50.0
Measured Q-P Data
40.0
30.0
20.0
10.0
0
150.0K
10.0M
1.0M
30.0M
Frequency (MHz)
CLP0212FPEX5Z03A + 2 x 4.7nF “Y” capacitors + 0.47µF “X” capacitors (208VAC in, 12V @ 180W out, Negative of
Output Grounded)
90.0
80.0
Amplitude (dBuV)
70.0
Class B Q-P Limits
60.0
50.0
Measured Q-P Data
40.0
30.0
20.0
10.0
0
150.0K
1.0M
10.0M
30.0M
Frequency (MHz)
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 11
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Mechanical Outline (all except CLP0212…Z02A & CLP0212…Z03A, C versions)
Dimensions are in millimeters.
Tolerances: x.x mm ± 0.5mm [unless otherwise indicated]
x.xx mm ± 0.25mm
VOUT
TOP VIEW
NEUTRAL
RTN
LINE
NEUTRAL
SIDE VIEW
3D-VIEW
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 12
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Mechanical Outline - CLP0212FPEX5Z02A
Dimensions are in millimeters.
Tolerances: x.x mm ± 0.5mm [unless otherwise indicated]
x.xx mm ± 0.25mm
TOP VIEW
SIDE VIEW
3D-VIEW
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 13
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Mechanical Outline - CLP0212FPEX5Z03A, C
Dimensions are in millimeters.
Tolerances: x.x mm ± 0.5mm [unless otherwise indicated]
x.xx mm ± 0.25mm
VOUT
TOP VIEW
RTN
LINE
NEUTRAL
SIDE VIEW
3D-VIEW
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 14
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Connector Information
Connector
Connector on Power Supply
Mating Connector
AC Input Connector (HDR1)
5-1376382-1 from Tyco or equivalent
1376388-1 from Tyco or equivalent
DC Output Connector (HDR2)
39-28-1043 from Molex or equivalent
39-01-2040 from Molex or equivalent
Signal Connector (HDR3)
53047-0810 from Molex or equivalent
51021-0800 from Molex or equivalent
DC Output Connector (HDR2)
Signal Connector (HDR3)
Pinout Information
AC Input Connector (HDR1)
Pin 1
Line
Pin 1
VO
Pin 1
Current Share
Pin 2
Neutral
Pin 2
VO
Pin 2
+S (Remote Sense +)
Pin 3
RTN
Pin 3
-S (Remote Sense -)
Pin 4
RTN
Pin 4
Remote On/Off
Pin 5
DC-OK (Output OK)
Pin 6
COM (Output Return)
Pin 7
COM (Output Return)
Pin 8
Standby Output
Note: Signal Connector HD3 is not present in the Z02A and Z03A, C versions.
February 14, 2017
©2017 General Electric Company. All rights reserved.
Page 15
GE
Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
Ordering Information
Please contact your GE Sales Representative for pricing, availability and optional features.
Table 2. Device Codes
Device Code
Input
Voltage Range
Output
Voltage
Output
Current
On/Off Control
Standby
Supply
Temperature
Range
Comcode
CLP0212FPXX5Z01A*
90 – 264Vac
12.0Vdc
16.7A
Negative Logic
5V@0.25A
-25 to 70ºC
150032000
CLP0212FPXX3Z01A*
90 – 264Vac
12.0Vdc
16.7A
Negative Logic
3.3V@0.25A
-25 to 70ºC
150032001
CLP0212FPEX5Z01A*
90 – 264Vac
12.0Vdc
16.7A
Negative Logic
5V@0.25A
-40 to 70ºC
150032002
CLP0212FPEX5Z02A*
90 – 264Vac
12.0Vdc
8.34A
Absent
Not accessible
-40 to 70ºC
150032003
CLP0212FPEX5Z03A*
90 – 264Vac
12.0Vdc
16.7A
Absent
Not accessible
-40 to 70ºC
150032004
CLP0212FPXX5Z03A*
90 – 264Vac
12.0Vdc
16.7A
Absent
Not accessible
-25 to 70ºC
150032005
CLP0212FPEX5Z01C
90 – 264Vac
12.0Vdc
16.7A
Negative Logic
5V@0.25A
-40 to 70ºC
150038518
CLP0212FPEX5Z03C
90 – 264Vac
12.0Vdc
16.7A
Absent
Not accessible
-40 to 70ºC
150038520
* Not recommended for new designs
Contact Us
For more information, call us at
USA/Canada:
+1 877 546 3243, or +1 972 244 9288
Asia-Pacific:
+86.021.54279977*808
Europe, Middle-East and Africa:
+49.89.878067-280
www.gecriticalpower.com
GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s)
or information.
February 14, 2017
©2017 General Electric Company. All International rights reserved.
Version 1.39