0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
J2007001L007A

J2007001L007A

  • 厂商:

    GEC(通用电气公司)

  • 封装:

    -

  • 描述:

    SHELF

  • 数据手册
  • 价格&库存
J2007001L007A 数据手册
GE Critical Power Quick Start Guide CP Converter Shelf System –48V Shelf: J2007001 L014 CC109157657 DC input from left and right L015 150042727 DC input from left only Converters: CP2000DC54PEZ CC109162104 CP2500DC54PEZ CC109170528 Controller: CP841_3C3R CC109145331 No vertical spacing is required, allow a minimum 2 inch clearance at back of shelf for rectifier airflow. Refer to Compact Power Line (CPL) Brochure for details and accessories. Tools required: Wire cutters and strippers Torque wrench - 0-65 in-lb (0-10Nm) Cable crimpers Sockets - 5/16”, 7/16, etc. Screwdrivers - Philips #1 and #2, Flat small Step 3 - Connect -48V Output and Output Return Step 1 - Mount Shelf Lugs - 1/4” on 5/8” centers (not provided). Torque to 65 in-lb (7.3 Nm) - 7/16” socket. 1. Reposition mounting ears as required - 8 screws each. Torque to 25 in-lb (2.8Nm) - Phillips screwdriver. 2. Attach shelf to the frame using a minimum of four screws (two on each side) - 12-24 (provided). Torque to 35 in-lb (4Nm) - 5/16” socket. Step 4 - Connect DC Inputs  Feed each input from 80A breaker (shelf rating limited) Lugs - 1/4” on 5/8” centers (not provided). Torque to 65 in-lb (7.3 Nm) - 7/16” socket Step 2 - Connect Chassis Ground Some applications may rely on frame mounting screws for shelf ground omitting the chassis ground cable. CAUTION: Verify DC Input voltage and polarity with a voltmeter before proceeding. Note: Input Feed Returns must be externally connected to DC Reference (CO) ground. Minimum 6 AWG wire is recommended. Lugs - 1/4” on 5/8” centers (not provided). Torque to 65 in-lb (7.3 Nm) - 7/16” socket. DC Inputs - Converter Inputs Output Return (Ground) -48V Output 4 3 1 POS NEG NEG POS 2 Chassis Ground L014 shown (L015 has all DC input feeds from the right as viewed from the rear) CP Converter Shelf - Quick Start Guide Document 850033106 r04 2015 April 1 J4 1-Wire Battery Temp and Voltage Monitor J1 Alarms and Inputs - page 4 J5 LAN Port RS-232 Craft port J2 External Alarm Inputs - page 4 J7 External Distribution Shelf.- page 4 Signal Connections Step 5 - Set Jumpers - LAN Port and Relay per Galaxy Pulsar Edge Controller Quick Start Guide Step 6 - Install Controller per Galaxy Pulsar Edge Controller Quick Start Guide Step 7 - Install Signal and Communications Cables Connectors are on rear. 1. J1-2 Alarms and Inputs - Connect to office alarms and signals. See Information: Alarm Connections for Details 2. J5 LAN - Connect to Ethernet network. 3. J7 DIST - Connect to external distribution - if present. Step 8 - Install 1-Wire Battery Temp and Voltage Monitor per Galaxy Pulsar Edge Controller Quick Start Guide - Optional 1. Connect 1-Wire Battery Temp and Voltage Monitor to J3 Step 9 - Install Converter s 1. Slide converter into its slot approximately 3/4 of the way. 2. Open the faceplate by sliding the faceplate latch to the left until the faceplate releases and swings outward. 3. Slide the unit into the slot until it engages with the back of the shelf. Swing the faceplate closed to fully seat the converter. Verify the faceplate is latched. Latch Step 10 - Initial Start Up Verify that all AC, DC and Alarm connections are complete and secure. Turn on AC input breakers. If there are no alarms, make required adjustments to the default settings on the controller for this installation. Step 11 - Configure Controller per Galaxy Pulsar Edge Controller Quick Start Guide Verify and edit controller basic configuration parameters per site engineering instructions. 2 CP Converter Shelf - Quick Start Guide Document 850033106 r04 2015 April Information: Alarm Connections See the Compact Power Line Brochure for details. Alarm connections are on the rear of the shelf - J1 is Alarm Outputs and J2 is Alarm Inputs. Change alarm descriptions via LAN port (Web pages) or Craft port (EasyView2) when required. Connector Controller Pin J2 - All Controllers J1 - Controller Variants Color 1 BK 2 BR 3 4 5 6 7 8 9 10 R O Y G BL V S W 0I5R_D - 5 Alarm Relays 3C3R - 3 Alarm Relays, 9C0R_USB - 9 Inputs Color Output: R3 = Rtn Output: R2 = Rtn Input: PBT/TR Input: Hi Ext. Temp. Input: PBT/TR Input: Hi Ext. Temp. Y Output: R1 = Rtn Output: PMN Rtn Output: PMJ Rtn Output: R3 = ACF Output: R2 = RFA Output: R1 = BD Output: PMN Output: PMJ Output: R1 = Rtn Output: PMN Rtn Output: PMJ Rtn Input: RTNS Input: Cust. Alrm 1 Output: R1 = BD Output: PMN Output: PMJ Input: Low Ext. Temp. Input: Fan Fail Input: Hydrogen Present Input: Returns Input: Cust. Alrm 1 Input: Cust. Alrm 2 Input: Cust. Alrm 3 Input: Cust. Alrm 4 O J1: 1. Includes a mixture of Alarm Inputs and / or Alarm Outputs depending on the controller model. 2. Connector Part: Cvilux HDR10-CP35H Alarm Inputs: 1. “dry” contacts, apply no voltage. 2. Return for all alarm inputs is pin 6. Alarm Outputs: relays contacts. S V W BL BR BK All Input: SPD Fail -Input: AUX MAJ Input: Air Cond. Fail Input: Door Open -48V -48V -48V J2: 1. Includes 4 Alarm Inputs. 2. Connector Parts: Molex 39-01-2086 Housing 39-00-0087 Contacts Alarm Inputs: 1. Contact closures or opens to -48V. 2. Pins 6, 7, and 8 provide -48V for these alarm inputs. Information: Connections - External Distribution - J7 J7 Pin Wire Color Description 1 BK FAJ 2 3 4 5 6 7 8 9 10 BR R O Y G BL V S W Coil Rtn LVD_NC LVD_NO Shunt OS Coil 1 Coil 2 LVD Status Return Shunt + J7: 1. Connector P/N Cvilux HDR10-CP35H CP Converter Shelf - Quick Start Guide Document 850033106 r04 2015 April 31 Specifications and Application  Specifications and ordering information are in the Compact Power Line (CPL) Brochure available at www.gecriticalpower.com  Equipment and subassembly ports: 1. are suitable for connection to intra-building or unexposed wiring or cabling; 2. can be connected to shielded intra-building cabling grounded at both ends.  Grounding / Bonding Network – Connect to an Isolated Ground Plane (Isolated Bonding Network) or an Integrated Ground Plane (MeshBonding Network or Common Bonding Network).  Installation Environment - Install in Network Telecommunication Facilities, OSP, or where NEC applies.  DC return may be either Isolated DC return (DC-I) or Common DC return (DC-C). Reference Documents These documents are available at www.gecriticalpower.com. Document Title 850035894 Galaxy Pulsar Edge Quick Start Guide CC848836981 Galaxy Pulsar Edge Controller Family Product Manual Compact Power Line (CPL) Brochure 2 4 CP Converter Shelf - Quick Start Guide GE ● 601 Shiloh Rd. ● Plano, TX 75074 ● 1- 888-546-3243 www.gecriticalpower.com Document 850033106 r04 2015 April
J2007001L007A 价格&库存

很抱歉,暂时无法提供与“J2007001L007A”相匹配的价格&库存,您可以联系我们找货

免费人工找货