712-419 Self-Locking Composite Conduit Adapter for Series 74 PEEK, PFA, ETFE, FEP or PTFE Tubing Shielding Optional
712 F T 419 XM 19 12-20 K-1 A
Product Series Connector Designator (A, F, H & U) Angular Function S - Straight T = 45° Elbow W = 90° Elbow Basic No. Finish (Table III) Shell Size (Table I) (See Note 1) Dash No. (Table II) Optional Length (See Note 3) Symbol "S" only Tubing Option (See Note 2) K = PEEK (Omit for PFA, ETFE, FEP, or PTFE) To accommodate EMI or Dacron overbraid (Omit if Not Required) Add Letter for Optional Configuration (See Detail A and Note 4) E +.06 (1.5) .720 .750 .750 .760 .780 .790 .820 .860 .890 .920 (18.3) (19.1) (19.1) (19.3) (19.8) (20.1) (20.8) (21.8) (22.6) (23.4)
A Thread Typ. (See Note 1) 1.250 (31.8) K - Entry Tubing shown for reference only (See Note1) Tubing I.D. J Typ (see Note 2)
Series 74 Convoluted Tubing
C AntiDecoupling Device G
Sym S – Straight
Knurl or Flute Style Manufacurer's Option, Typ. E F
Sym W 90°
H
Sym T 45° Raised configuration (Mfr's option)
Dash 1 configuration EMI or Dacron over Braid (See P/N Development)
Table I
Shell Size A,F & H G&U 08, 09 03, 10, 11 12, 13 14, 15 16, 17 18, 19 20, 21 22, 23 24, 25, 61 28 – 08 10, 11 12, 13 14, 15 16, 17 18, 19 20 22, 23 24, 25 F +.09 (2.3) .890 .950 1.020 1.050 1.070 1.080 1.110 1.150 1.180 1.210 (22.6) (24.1) (25.9) (26.7) (27.2) (27.4) (28.2) (29.2) (30.0) (30.7) G +.06 (1.5) .690 .750 .810 .880 .940 .970 1.060 1.130 1.190 1.340 (17.5) (19.1) (20.6) (22.4) (23.9) (24.6) (26.9) (28.7) (30.2) (34.0) H +.09 (2.3) 1.110 1.160 1.220 1.290 1.350 1.380 1.470 1.540 1.730 1.820 (28.2) (29.5) (31.0) (32.8) (34.3) (35.1) (37.3) (39.1) (43.9) (46.2) Tubing Size Max. 09 12 16 20 24 28 32 32 40 40
Table II
Dash Conduit No. I.D. 06 .188 (4.8) 09 .281 (7.1) 10 .312 (7.9) 12 .375 (9.5) 14 .437 (11.1) 16 .500 (12.7) 20 .625 (15.9) 24 .750 (19.1) 28 .875 (22.2) 32 1.000 (25.4) 40 1.250 (31.8) 48 1.500 (38.1) J Dia Max .540 (13.7) .630 (16.0) .690 (17.5) .730 (18.5) .800 (20.3) .870 (22.1) 1.000 (25.4) 1.180 (30.0) 1.320 (33.5) 1.470 (37.3) 1.760 (53.3) 2.130 (54.1) K Entry .120 (3.0) .220 (5.6) .240 (6.1) .290 (7.4) .340 (8.6) .400 (10.2) .520 (13.2) .650 (16.5) .780 (19.8) .900 (22.9) 1.080 (27.4) 1.320 (33.5) XM XW XB XO
Table III TABLE 2
Electroless Nickel Cadmium Olive Drab Over Electroless Nickel No Plating - Black Material No Plating - Base Material Non-conductive
NOTES: 1. Convoluted tubing size, tubing to be ordered seperately (see Series 74 Catalog, Type A Tubing Section, Standard Pitch). Dash 1 configuration accommodates Type B or D Tubing. 2. Different adapters are necessary to terminate PEEK tubing. Nominal I.D. reduced by approximately .060 (use Suffix P) in P/N development. 3. Add optional length in 1/4 inch increments: 20 = 5.00 inches. Omit for standard 1.250 length. 4. For permanant installation suse 3M Scotch Weld Tape after installing Metric dimensions (mm) are in parentheses and are for reference only. tubing/shield (see Detail A).
© 2003 Glenair, Inc.
CAGE Codes 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912 www.glenair.com E-Mail: sales@glenair.com D-32