EMI/RFI Environ.
Backshells
AS85049/17
Straight EMI/RFI Environmental Backshell
CONNECTOR DESIGNATOR:
F
N = Electroless Nickel
W = 1,000 Hr. Cadmium Olive Drab
over Electroless Nickel
MIL-DTL-38999, Series I and II
40M38277, PAN 6433-1
PATT 614, PATT 616
NFC93422 Series HE308 and HE309
M85049/17
Basic
Part Number
Finish
X = Aluminum, Nickel Flurocarbon Polymer
Z = Aluminum, Zinc-Nickel, Black
10
N
03
Clamp Size
(Table III)
Dash Number
(Table I)
TABLE I: Shell Size,
Thread and Dimensions
39
Dash
No.
08
10
12
14
16
18
20
22
24
Series I
Shell
Size
Series II
A Thread
Class 2B
B Dia
Max
09
11
13
15
17
19
21
23
25
08
10
12
14
16
18
20
22
24
.438 - 28 UNEF
.562 - 24 UNEF
.688 - 24 UNEF
.813 - 20 UNEF
.938 - 20 UNEF
1.063 - 18 UNEF
1.188 - 18 UNEF
1.313 - 18 UNEF
1.438 - 18 UNEF
.570 (14.5)
.700 (17.8)
.830 (21.1)
.950 (24.1)
1.080 (27.4)
1.200 (30.5)
1.330 (33.8)
1.450 (36.8)
1.580 (40.1)
Shell
Size
TABLE II: Shell Size
and Clamp Size
Shell
Size
Shell
Size
Dash
No.
Series I
Series II
08
10
12
14
16
18
20
22
24
09
11
13
15
17
19
21
23
25
08
10
12
14
16
18
20
22
24
Length Code
(Table IV)
Omit for Standard
TABLE III: Clamp Size, Cable Range and Dimensions
Clamp Size
Min Max
01
01
02
02
02
03
03
03
04
A
02
03
04
05
06
07
08
09
10
Clamp
Size
Min
Cable Range
Max
01
02
03
04
05
06
07
08
09
10
.062 (1.6)
.125 (3.2)
.250 (6.4)
.375 (9.5)
.500 (12.7)
.625 (15.9)
.750 (19.1)
.875 (22.2)
1.000 (25.4)
1.125 (28.6)
.125 (3.2)
.250 (6.4)
.375 (9.5)
.500 (12.7)
.625 (15.9)
.750 (19.1)
.875 (22.2)
1.000 (25.4)
1.125 (28.6)
1.250 (31.8)
E
Max
.781 (19.8)
.969 (24.6)
1.062 (27.0)
1.156 (29.4)
1.250 (31.8)
1.375 (34.9)
1.500 (38.1)
1.625 (41.3)
1.750 (44.5)
1.875 (47.6)
F
Max
1.250 (31.8)
1.250 (31.8)
1.250 (31.8)
1.250 (31.8)
1.312 (33.3)
1.375 (34.9)
1.500 (38.1)
1.625 (41.3)
1.625 (41.3)
1.625 (41.3)
APPLICATION NOTES
TABLE IV: Length Code
© 2012 Glenair, Inc.
1.
Length
Code
Available
Shell Sizes
Length
Standard
A
B
C
08 - 24
08 - 24
14 - 24
20 - 24
1.500 (38.1)
2.500 (63.5)
3.500 (88.9)
4.500 (114.3)
2.
3.
For complete dimensions
see the applicable Military
Specification.
Metric dimensions (mm) are in
parentheses.
Cable Range is defined as
the accommodation range
for the wire bundle or cable.
Dimensions shown are not
intended for inspection criteria.
CAGE Codes 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
E-Mail: sales@glenair.com
39-16
www.glenair.com