GPTR3190
PHASE CONTROLLED SCR
High reliability operation DC power supply AC drives
VOLTAGE UP TO AVERAGE CURRENT SURGE CURRENT BLOCKING CHARACTERISTICS Characteristic
VRRM VRSM VDRM IDRM IRRM Repetitive peak reverse voltage Non-repetitive peak reverse voltage Repetitive peak off-state voltage Repetitive peak off-state current, max. Repetitive peak reverse current, max. VDRM, single phase, half wave, Tj = Tjmax VRRM, single phase, half wave, Tj = Tjmax
2400 V 1900 A 22 kA
Conditions
Value
2400 V 2500 V 2400 V 70 mA 70 mA
ON-STATE CHARACTERISTICS
IT(AV) IT(RMS) ITSM I²t VT(TO) Average on-state current R.M.S. on-state current Surge on-state current I² t for fusing coordination Threshold voltage On-state slope resistance Peak on-state voltage, max Holding current, max Latching current, typ Tj = Tjmax Tj = Tjmax On-state current IT = 5000 A , Tj = 25 °C Tj = 25 °C Tj = 25 °C Sine wave,180° conduction, Th = 55 °C Sine wave,180° conduction, Th = 55 °C Non rep. half sine wave, 50 Hz, VR = 0 V, Tj = Tjmax 1900 A 2984 A 22 kA 2420 kA²s 1,04 V 0,23 mΩ 2,15 V 300 mA 500 mA
rT
VTM IH IL
TRIGGERING CHARACTERISTICS
VGT IGT VGD PGM PG(AV) IFGM VFGM VRGM Gate trigger voltage Gate trigger current Non-trigger voltage Peak gate power dissipation Average gate power dissipation Peak gate current Peak gate voltage (forward) Peak gate voltage (reverse) Tj = 25 °C, VD = 5 V Tj = 25 °C, VD = 5 V VD = 67% VRRM, Tj = Tjmax Pulse width 0.5 ms 3V 400 mA 0,15 V 100 W 5W 30 A 12 V 3V
SWITCHING CHARACTERISTICS
di/dt dV/dt tq Critical rate of rise of on-state current Critical rate of rise of off-state voltage Turn-off time, typ Tj = Tjmax Tj = Tjmax Tj = Tjmax, IT = 800 A, di/dt = -12.5 A/µs VR = 100 V, VD = 67% VDRM, dV/dt = 20 V/µs 200 A/µs 1000 V/µs 400 µs
THERMAL AND MECHANICAL CHARACTERISTICS
Rth(j-c) Rth(c-h) Tjmax Tstg F Thermal resistance (junction to case) Thermal resistance (case to heatsink) Max operating junction temperature Storage temperature Clamping force ± 10% Mass Double side cooled Double side cooled 0,016 °C/W 0,001 °C/W 125 °C -40 / 125 °C 30 kN 1400 g
Document GPTR3190T001
PHASE CONTROLLED SCR
GPTR3190
Current rating - sine wave
Power loss - sine wave
Heatsink temperature [°C]
130 120 110 90 80 70 60 50 0 500
30° 60° 90° 120° 180°
1000 IT [A]
1500
2000
PF [W]
100
4500 4000 3500 3000 2500 2000 1500 1000 500 0 0 500
180°
90° 60° 30° 120°
1000 IT[A]
1500
2000
Maximum surge current d.s. cooled 25 20 ITSM [A] I [A] ITT[A] 15 10 5 0 1 10 Number of cycle current pulses [n] 100
On-state voltage drop
4000 4000 3500 3500 3000 3000 2500 2500 2000 2000 1500 1500 1000 1000 500 500 0 0 0 0 0,5 0,5 1 1
Tj=T Tj=Tjmax jmax
1,5 VT V] VT [[V]
2
2,5
Thermal impedance (j-c)
0,018 0,016 0,014 0,012 0,01 0,008 0,006 0,004 0,002 0 0,001
ZTH(j-c) [°C / W]
0,01
0,1 Time [s]
1
10
100
dimensions mm
In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet
without notice. Document GPTR3190T001