70-ODC15

70-ODC15

  • 厂商:

    GRAYHILL

  • 封装:

  • 描述:

    70-ODC15 - DC Output Modules - Grayhill, Inc

  • 数据手册
  • 价格&库存
70-ODC15 数据手册
DC Output Modules FEATURES • Transient Protection: Meets the requirements of IEEE 472, "Surge Withstanding Capability Test" • SPST, Normally Open • UL, CSA, CE, TÜV Certified • Optical Isolation • OpenLine® and G5 Modules Provide Replaceable 5x20mm Glass Fuses • Built-in Status LED • Lifetime Warranty 70L-ODC 70G-ODC 70-ODC 70M-ODC DIMENSIONS For complete dimensional drawings, see pages L-4 or L-5. LOAD CURRENT (AMPS) 4 3 2 1 STANDARD, G5 PACKAGES MINIATURE PACKAGE FUSES G5 Fuses are 5 Amp Littelfuse part number 217005 or equivalent. OpenLine® fuses are 3.15 Amp Littelfuse part number 2173.15. Fuse kits available, see page L-104. OPENLINE PACKAGE/CH Maximum Current Versus Ambient Temperature The chart indicates continuous current to limit the junction temperatures to 115°C. Information is based on steady state heat transfer in a 2 cubic foot sealed enclosure. 200 VDC STYLE -40˚ -20˚ 0 20˚ 40˚ 60˚ 80˚ AMBIENT TEMPERATURE (˚C) 100˚ CIRCUITRY Standard, Mini, G5 + VDC LOAD 1 Figure 1 OpenLine ® TYPICAL WIRING FOR MODULE 0 VOLTAGE SPIKE PROTECTION LOAD 2 I/O MODULE PIN # + – GND 5 Vcc 6 A CH. A CONTROL 7 CHANNEL A OPTICAL ISOLATION DRIVER CIRCUIT 1 2 1 2 LOAD – DC SUPPLY DRIVER CIRCUIT + B OPTICAL ISOLATION DRIVER CIRCUIT 3 3 DC SUPPLY + DC CONTROL Rx 3 4 CH. B 8 CONTROL 2.15K MODULE ID 9 CHANNEL B – 4 BASE OR RACK 4 LOAD I/O Modules 1 2 3 4 – TERMINAL BLOCK # Fuse and status LED in G5 and OpenLine modules only. SPECIFICATIONS: By Package Style Package Style Specifications Load Current Range Surge Current for 1 Sec. Maximum Reverse Logic Voltage Isolation Voltage2 Vibration3 Mechanical Shock4 Storage Temp. Range Operating Temp. Range Warranty 1 Std (70-) Units A A Vdc Vrms 0.02-3.5 5 -5 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime Mini (70M-) G5 (70G-) OL (70L-) °C °C 0.02-3.0 5 -5 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.02-3.5 5 -5 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.02-2.0/CH 5 -5 2500 IEC68-2-6 IEC68-2-27 -40 to 100 -40 to 85 Lifetime See Figure 1 for derating. Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g. I/O 8 G rayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com DC Output Modules SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Miniature, Normally Open Standard, Normally Open Specifications Maximum Line Voltage Load Voltage Range Max. Off-State Leakage @ Max. Line Maximum Turn-On Time Maximum Turn-Off Time Typ. Power Dissipation Clamping Voltage Nominal Logic Voltage (Vcc) Logic Voltage Range Maximum Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Units Vdc Vdc mA µSec µSec W/A Vdc Vdc Vdc mA Ω Vdc 60 3-60 1.5 20 50 1 80 5 2.5-10 14 300 1 200 4-200 0.01 75 750 1.5 360 5 2.5-9 18 220 1 60 3-60 0.01 75 500 1 80 5 2.5-10 14 300 1 60 3-60 1.5 20 50 1 80 15 10-18 9 1800 1 60 3-60 0.01 75 500 1 80 15 10-18 9 1800 1 60 3-60 1.5 20 50 1 80 24 15-30 9 2700 1 60 3-60 0.01 75 500 1 80 24 15-30 9 2700 1 Grayhill Part Number 70M-ODC5 70M-ODC5A 70M-ODC5B 70M-ODC15 70-ODC5 70-ODC5A 70-ODC5B 70-ODC15 70M-ODC15B 70-ODC15B 70M-ODC24 70M-ODC24B 70-ODC24 70-ODC24B G5 and OpenLine® Modules Type/Function Fusible, Normally Open Specifications Maximum Line Voltage Load Voltage Range Max. Off-State Leakage @ Max. Line Maximum Turn-On Time Maximum Turn-Off Time Typ. Power Dissipation Clamping Voltage Nominal Logic Voltage (Vcc) Logic Voltage Range Maximum Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Units Vdc Vdc mA µSec µSec W/A Vdc Vdc Vdc mA Ω Vdc 60 3-60 1.5 20 50 1 80 5 4-6 13 150 1 200 4-200 0.01 75 750 1.5 360 5 4-6 13 150 1 60 3-60 0.01 75 500 1 80 5 4-6 13 150 1 60 3-60 1.5 20 50 1 80 15 10-20 9 1500 1 60 3-60 0.01 75 500 1 80 15 10-20 9 1500 1 60 3-60 1.5 20 50 1 80 24 18-32 9 2700 1 60 3-60 0.01 75 500 1 80 24 18-32 9 2700 1 70G-ODC5 70G-ODC5 70G-ODC5A 70G-ODC5B Grayhill Part Number 70G-ODC15 70G-ODC15B 70G-ODC24 70G-ODC24B OpenLine® Modules Type/Function Dual, Fusible, Normally Open Specifications Maximum Line Voltage Load Voltage Range Max. Off-State Leakage @ Max. Line Maximum Turn-On Time Maximum Turn-Off Time Typ. Power Dissipation Clamping Voltage Nominal Logic Voltage (Vcc) Logic Voltage Range Maximum Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground Minimum Drop Out Voltage Units Vdc Vdc mA µSec µSec WA Vdc Vdc Vdc mA Ω Vdc 60 3-60 1.5 20 50 1 80 5 4.5-28 7/CH 2.15K 1 200 4-200 .01 75 750 1.5 360 5 4.5-28 7/CH 2.15K 1 60 3-60 .01 75 500 1 80 5 4.5-28 7/CH 2.15K 1 Grayhill Part Number 70L-ODC 70L-ODCA 70L-ODCB Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. I/O Modules Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com I/O 9
70-ODC15 价格&库存

很抱歉,暂时无法提供与“70-ODC15”相匹配的价格&库存,您可以联系我们找货

免费人工找货