Dry Contact and Mechanical Relay Output Modules
FEATURES • SPST, Normally Open • UL, CSA Certified • 1500 Vac Optical Isolation • G5 and OpenLine® Modules Provide Replaceable 5x20mm Glass Fuse • Built-in Status LED • Lifetime Warranty • Switch AC or DC with the Same Module • Very Low Off-State Leakage Current for AC loads • No Off-State Leakage Current for DC loads
70L-ODC5R 70G-ODCR/OACRLY 70-ODCR/OACRLY 70M-ODCR
CIRCUITRY
Standard, Mini, G5
LOAD
VAC/VDC
1
OpenLine®
1
2
5
LOAD
2
+VCC
3
AMP
6 7
AMP INPUT
4
3
8
AMP
4 9
GROUND
5
Fuse and status LED in G5 modules only.
I/O Modules
SPECIFICATIONS BY PACKAGE STYLE
Package Style Specifications Isolation Voltage Vibration2 Mechanical Shock3 Storage Temp. Range Operating Temp. Range
1 2 1
Std (70-) Units Vrms 1500 MIL-STD-202 MIL-STD-202 -40 to 70 -40 to 70
Mini (70M-)
G5 (70G-)
OpenLine® (70L-)
°C °C
1500 MIL-STD-202 MIL-STD-202 -40 to 70 -40 to 70
1500 MIL-STD-202 MIL-STD-202 -40 to 70 -40 to 70
1500 IEC68-2-6 IEC68-2-7 -40 to 70 -40 to 70
Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. 3 MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g.
I/O 10
G rayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Dry Contact and Mechanical Relay Output Modules
SPECIFICATIONS BY PART NUMBER
Standard and Miniature Modules
Type/Function Miniature, Normally Open Standard, Normally Open Specifications Maximum Line Voltage Load Voltage Range Maximum Contact Rating Maximum Switching Current1 Maximum Carry Current1 Minimum Life Expectancy @ 10 Vdc/10 mA @ 48 Vdc/100 mA @ 120 Vac/80 mA @ 30 Vdc or 230 Vac/3A Maximum Contact Resistance Maximum Off-State Leakage Maximum Turn-On Time2 Maximum Turn-Off Time2 Nominal Logic Voltage (Vcc) Logic Voltage Range Maximum Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop-Out Voltage Maximum Reverse Logic Voltage Units Vdc/Vac Vdc/Vac W A A Cycles Cycles Cycles Cycles mΩ mA mSec mSec Vdc Vdc mA Ω Vdc Vdc 100/120 0-100/0-120 10 0.5 1.0 200 x 106 500 x 103 500 x 103 — 250 .002 1 1 5 4.8-6.0 10 500 2.5 -5 110/250 0-110/0-250 90 3.0 5.0 — — — 100 x 10 6 250 .002 11 11 5 4.8-6.0 26 200 4.8 -5 100/120 0-100/0-120 10 0.5 1.0 200 x 106 500 x 103 500 x 103 — 250 .002 1 1 24 20-30 16 1700 23 -5 70M-ODC5R 70-ODC5R Grayhill Part Number 70-OAC5RLY 70M-ODC24R 70-ODC24R
G5 and OpenLine® Modules
Type/Function G5 Fusible, Normally Open Specifications Maximum Line Voltage Load Voltage Range Maximum Contact Rating Maximum Switching Current1 Maximum Carry Current1 Minimum Life Expectancy @ 1Vdc/10 mA @ 10 Vdc/10 mA @ 48 Vdc/100 mA @ 120 Vac/80 mA @ 30 Vdc or 230 Vac/3A Maximum Contact Resistance Maximum Turn-On Time2 Maximum Turn-Off Time 2 Max. Off-State Leakage @ Max. Line Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop-Out Voltage
1 2
Grayhill Part Number 70L-ODC5R Units Vdc/Vac Vdc/Vac W A A Cycles Cycles Cycles Cycles Cycles mΩ mSec mSec mA Vdc Vdc mA Ω Vdc 200/200 0-200/0-200 10 0.5 1.5 1000 x 106 — — 500 x 103 300 1 1 .002 5 4.5-6.0 30 max./channel 167 4.5 100/120 0-100/0-120 10 0.5 1.0 — 200 x 106 500 x 103 500 x 103 — 250 1 1 .002 5 4.8-6.0 10 500 1 110/250 0-110/0-250 90 3.0 5.0 — — — — 100 x 106 250 11 11 .002 5 4.8-6.0 26 200 1 100/120 0-100/0-120 10 0.5 1.0 — 200 x 106 500 x 103 500 x 103 — 250 1 1 .002 24 18-32 23 1200 23 70G-ODC5R 70G-OAC5RLY 70G-ODC24R
I/O Modules
Inductive loads require diode suppression or RC network. Times include debounce.