PRODUCT ADVISORY NOTICE
KEEPING YOU INFORMED OF PRODUCT CHANGES
To:
All 90 Series DIP Switch Customers, Sales Representatives and Distributors
Date:
July 20, 2014
Subject:
Base and Cover Plastic Material Change
This Product Advisory Notice is to alert you that there is a coming change to a series of Grayhill DIP switches and
our records show your company has purchased one or more of the affected part numbers in the past. Please
forward this notification to the appropriate person(s) in your organization.
Description of the Change
The thermoplastic material that is used in the base and cover piece parts is changing from 30% glass filled
polyamide (PA46) to 33% glass filled polyphthalamide (PPA).
Reason for Change
The new material performs better than the current material in reflow process applications where more demanding
process temperatures as used. The new material also improves the tape seal adhesion to the switches by virtue
of being less susceptible to moisture absorption during processing or storage. The new material has the added
benefit of being Halogen Free and of meeting all current RoHS and REACH requirements.
Effective Date
All two through eight position 90 Series DIP switches manufactured after August 30th (date code 1436 or later)
may be built with either PA46 or PPA.
Part Numbers Affected
The table below lists the Grayhill part numbers included in the change notice:
2s
3s
5s
6s
8s
10s
90B02SLT
90B03ST
90B05SLT
90B06ST
90B08SLT
90B10SLT
90YY2882R
90YY3143SGWR
90B02ST
90HBJ03PT
90B05ST
90B06T
90B08ST
90B10ST
90YY2901S
90YY3145SGWR
90HBJ02PRT
90HBW03PRT
90HBJ05PRT
90CR06SGWRT 90GB08ST
90GB10ST
90YY2923SGWR 90YY3148SGWR
90HBJ02PT
90HBW03PT
90HBJ05PT
90HBJ06PRT
90HBJ08PRT
90HBJ10PRT
90YY2928SGWR 90YY3203SGWR
90HBW05PRT
90HBJ06PT
90HBJ08PT
90HBJ10PT
90YY3048S
90YY3205SGWR
90HBW02PRT
Custom
90HBW02PT
7s
90HBW05PT
90HBW06PRT
90HBW08PRT
90HBW10PRT
90YY3048SR
90YY3326PR
90HBW02RT
90B07ST
90HBW05T
90HBW06PT
90HBW08PT
90HBW10PT
90YY3062SR
90YY3370PR
90HBW02T
90HBW07PRT
90HGBW05PRT
90HBW08RT
90HBW08RT
90YY3111SR
90YY3371PR
90HBW07PT
90YY3142SGWR 90YY3372SGWR
Test Data Available
A summary of the tests performed on the new material is attached to this notice. The full test report is available
on: http://www.grayhill.com/about-us/product-advisory-notices/
Action Required
Please forward this notification to the appropriate person(s) in your organization. No other action is
required. However, if you would like to receive a free sample, please contact your Grayhill, Inc. sales associate.
561 Hillgrove Avenue • LaGrange, Illinois • 60525-5997 • Ph: 708.354.1040 • Fax: 708.354.2820
1.3.
TEST SUMMARY
Table 1 – Test Summary
Test Description
Thermal shock
Mechanical Life
Dielectric Withstand Voltage
Contact Resistance
Moisture Resistance
Insulation Resistance
Resistance to Reflow Solder
Processing
Process Seal
Mechanical Shock
Vibration Resistance
Terminal Strength
Thermal Aging
Solderability
Flammability
Operating Force
Basic Standard
MIL-STD-202 Method 107G,
PS90 – 90 Series Product
Specification
MIL-STD-83504/12,
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 301,
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 307,
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 106,
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 302,
PS90 – 90 Series Product
Specification
Test Results
PASS
PASS
PASS
PASS
PASS
PASS
PS90 – 90 Series Product
Specification
PASS
MIL-STD-202 Method 112,
PS90 – 90 Series Product
Specification
PASS
MIL-STD-202 Method 213,
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 204
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 211A,
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 108A ,
PS90 – 90 Series Product
Specification
MIL-STD-202 Method 208,
PS90 – Series Product
Specification
IEC Standard 60695-11-5
UL-94, PS90 – 90 Series
Product Specification
PS90 – 90 Series Product
Specification
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Test Date
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
01/30/2014
To
02/24/2014
Test Location
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
Grayhill, Inc.
5 of 37
OPS Form #333, Rev A
11/12/12
Report SM04-17 Rev. A
很抱歉,暂时无法提供与“90HGBW05PRT”相匹配的价格&库存,您可以联系我们找货