MODULE
Mini-spectrometer TM series
C10082MD, C10083MD
Integrating optical system, image sensor and circuit
TM series mini-spectrometers are polychromators integrated with optical elements, an image sensor and a driver circuit. Two models are available: C10082MD (TM-UV/VIS-MOS) and C10083MD (TM-VIS/NIR-MOS). Light to be measured is guided into the entrance port of TM series through an optical fiber and the spectrum measured with the built-in image sensor is output from the USB port to a PC for data acquisition. No external power supply is required since USB bus power is used for circuit operation. The TM series comes with sample software, device driver and DLL. The sample software lets you easily set measurement conditions, acquire and save data, and display graphs.
Features
Applications
l High throughput due to transmission grating made of quartz l Light source spectrum measurement l Sunlight or illumination analysis l Highly accurate optical characteristics l No external power supply required: Uses USB bus power l Absorbance measurement l Wide spectral response range l Easy to install into equipment l Wavelength conversion factor *1 is recorded in internal memory
s O p tic a l c h a ra c te ris tic s P a ra m e te r S p e c tra l re s p o n s e ra n g e S p e c tra l re s o lu tio n M a x . (S p e c tra l re s p o n s e h a lf w id th ) * 2 W a v e le n g th re p ro d u c ib ility * 3 W a v e le n g th te m p e ra tu re d e p e n d e n c e S p e c tra l s tra y lig h t * 2 , * 4 s E le c tric a l c h a ra c te ris tic s P a ra m e te r A /D c o n v e rs io n In te g ra tio n tim e In te rfa c e U S B b u s p o w e r c u rre n t c o n s u m p tio n T M -U V /V IS - M O S C10082MD 2 0 0 to 8 0 0 6 ± 0 .2 0 .0 2 -3 5 T M -V IS /N IR - M O S C10083MD 3 2 0 to 1 0 0 0 8 U n it nm nm nm n m /° C dB
Va lu e 16 5 to 1 0 0 0 0 U S B 1 .1 100
U n it b it ms mA
s G e n e ra l ra tin g s / A b s o lu te m a x im u m ra tin g s P a ra m e te r Va lu e U n it D im e n s io n s 9 4 (W ) × 9 0 (D ) × 5 5 (H ) mm Im a g e s e n s o r C M O S lin e a r im a g e s e n s o r (S 8 3 7 8 -1 0 2 4 Q ) N u m b e r o f p ix e ls 1024 p ix e ls S lit * 5 7 0 (H ) × 8 0 0 (V ) µm O p tic a l N A 0 .2 2 C o n n e c to r fo r o p tic a l fib e r SMA905D O p e ra tin g te m p e ra tu re * 6 + 5 to + 4 0 °C S to ra g e te m p e ra tu re -2 0 to + 7 0 °C * 1 : A c o n v e rs io n fa c to r fo r c o n v e rtin g th e im a g e s e n s o r p ix e l n u m b e r in to a w a v e le n g th is re c o rd e d in th e m o d u le . A c a lc u la tio n fa c to r fo r c o n v e rtin g th e A /D c o n v e rte d c o u n t in to th e in p u t lig h t in te n s ity is n o t p ro v id e d . * 2 : D e p e n d s o n th e s lit o p e n in g . Va lu e s w e re m e a s u re d w ith th e s lit o p e n in g lis te d in th e ta b le . * 3 : M e a s u re d u n d e r c o n s ta n t lig h t in p u t c o n d itio n s * 4 : W h e n m o n o c h ro m a tic lig h t o f th e fo llo w in g w a v e le n g th s is in p u t, s p e c tra l s tra y lig h t is d e fin e d a s th e ra tio o f th e c o u n t m e a s u re d a t th e in p u t w a v e le n g th , to th e c o u n t m e a s u re d in a re g io n o f th e in p u t w a v e le n g th ± 4 0 n m . C 10082M D : 500 nm , C 10083M D : 650 nm * 5 : E n tra n c e s lit a p e rtu re s iz e * 6 : N o c o n d e n s a tio n L ig h t s p e c tra lly s e p a ra te d b y a g ra tin g is fo c u s e d a c c o rd in g to lig h t w a v e le n g th o n p re d e te rm in e d im a g e s e n s o r p o s itio n s , a n d h ig h -o rd e r lig h t is a ls o in p u t o n to p o s itio n s a t in te g e r-m u ltip le s o f w a v e le n g th s . In th e s e m in i-s p e c tro m e te rs a n o p tic a l filte r is a tta c h e d to th e im a g e s e n s o r to c u t o ff h ig h -o rd e r lig h t, b u t th is a ls o c a u s e s a d ro p in th e im a g e s e n s o r o u tp u t a t th e fo llo w in g w a v e le n g th s . C 10082M D : N ear 340 nm and 500 nm , C 10083M D : N ear 500 nm and 700 nm Ty p e s n o t u s in g a h ig h -o rd e r lig h t c u t o ff filte r a re a ls o a v a ila b le . P le a s e s p e c ify b y a d d in g “-0 1 ” to th e ty p e n u m b e r w h e n o rd e rin g . (E x a m p le : C 1 0 0 8 2 M D -0 1 )
1
Mini-spectrometer TM series
s Optical component layout
TM series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a rugged optical base, making it possible to deliver high throughput and highly accurate optical characteristics.
ENTRANCE SLIT COLLIMATING LENS TRANSMISSION GRATING
C10082MD, C10083MD
s Connection example (transmission light measurement)
Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable measurements are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement setup.
UV-VIS FIBER LIGHT SOURCE (Deuterium lamp and Halogen lamp) L10290
MINISPECTROMETER USB CABLE PC
FOCUSING MIRROR
IMAGE SENSOR
KACCC0287EA
FIBER
QUARTZ CELL (For holding liquid sample)
KACCC0288EF
s Dedicated software package (supplied with unit)
Installing the dedicated software package (containing sample software, device driver, DLL)*7 into your PC allows running the following basic tasks: · Measurement data acquisition and save · Measurement condition setup · Module information acquisition (wavelength conversion factor, polychromator type, etc.) · Graphic display · Arithmetic operation Pixel number to wavelength conversion Dark subtraction Comparison calculation with reference data (transmittance, reflectance) Gaussian approximation (peak position and count, FWHM) Note: Two or more mini-spectrometers can be connected and used with one PC simultaneously. *7: Compatible OS: Microsoft Windows Professional Edition 2000 (SP3 or later) and XP (SP1a or later) Device driver and DLL for controlling hardware are also provided. You can develop your own measurement programs by using a software development environment that includes Microsoft Visual C++ and Visual Basic.*8 The DLL provides functions such as USB port open/close, measurement condition setup, measurement data and module information acquisition. *8: Operation of the device driver and DLL has been verified only with Microsoft Visual C++® and Visual Basic®. Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States.
2
Mini-spectrometer TM series
s Measurement example
Line spectra from LED were measured with C10082MD (TM-UV/VIS-MOS)
40000 ORANGE LED (Typ. Ta=25 ˚C) RED LED
C10082MD, C10083MD
s Dimensional outline (unit: mm)
94
30000 BLUE LED
AD COUNT
20000
10000
0 200
300
400
500
600
700
800
WAVELENGTH (nm)
KACCB0126EA KACCA0171EC
s Accessories
· USB cable · Dedicated software (sample software, device driver, DLL)
s Options (sold separately)
Optical fibers for light input Type. No A9762-01 Product name Fiber for UV/visible range (resistance to UV) Core diameter (µm) 600 Specification N.A.=0.22, length 1.5 m, connectorized SMA905D at both ends
55
90
3
Mini-spectrometer TM series
C10082MD, C10083MD
n
Mini-spectrometer line-up
Type No. Type
TM-UV/VIS-CCD High sensitivity TM-UV/VIS-CCD High resolution
Spectral response range (nm)
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Spectral resolution Max. (nm)
Image sensor
C10082CA C10082CAH
6
200 to 800
1* 6
Back-thinned type CCD image sensor
TM series
C10082MD C10083CA C10083CAH C10083MD C9404CA
TM-UV/VIS-MOS Wide dynamic range TM-VIS/NIR-CCD High sensitivity TM-VIS/NIR-CCD
CMOS linear image sensor
High resolution
TM-VIS/NIR-MOS Wide dynamic range TG-UV-CCD High sensitivity TG-UV-CCD
320 to 1000
8 (λ=320 to 900 nm) Back-thinned type CCD image sensor 1* (λ=320 to 900 nm) 8 3
CMOS linear image sensor Back-thinned type CCD image sensor Back-thinned type CCD image sensor CMOS linear image sensor
TG series
C9404CAH
C9404MC C9405CA C9405MC C9406GC C9913GC C9914GB C9407MA
* Typ.
High resolution
TG-UV-MOS
200 to 400
1*
3
Wide dynamic range
TG-SWNIR-CCD High sensitivity
500 to 1100
TG-SWNIR-MOS Wide dynamic range TG-NIR
Back-thinned type 5 (λ=550 to 900 nm) CCD image sensor
5 (λ=550 to 1100 nm) 7
900 to 1700
NMOS linear image sensor
TG series
Non-cooled type
TG-cooled NIR-I
Low noise (cooled type)
TG-cooled NIR-II
7
1100 to 2200 340 to 780
InGaAs linear image sensor
Low noise (cooled type)
8 9
CMOS linear image sensor
RC series
RC-VIS-MOS
Spectrometer module
OEM model
Type No.
RC series
Type
RC-VIS-MOS
Spectral response range (nm)
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Spectral resolution Max. (nm)
Image sensor
CMOS linear image sensor
C9409MA
Spectrometer head
340 to 780
9
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2007 Hamamatsu Photonics K.K.
HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741 Cat. No. KACC1119E05
4
Jan. 2007 DN