High Current Fuses
MEGA® and MEGA® Clear Top Fuse Rated 32V
The MEGA® Fuse is designed for high current circuit protection up to 500A with “Diffusion
Pill Technology.” The MEGA® Fuse also provides time delay characteristics. Designed and
patented by Littelfuse, the MEGA® Fuse is ideal for battery and alternator protection application
and other heavy gauge cables requiring ultra-high current protection.
Specifications
MEGA ® Fuses
MEGA ® Clear Top Housing Fuse
Time-Current Characteristic Curves
10000
1000
100
TIME [s]
Ordering Information
Time-Current Characteristics
Package
Bolt Bolt Hole
Plating
Size
Size
Qty
Opening Time Min / Max (s)
Rating
40-250
300-500
0298xxx.ZXEH
80 - 250
500
None
M8
2
75
–/–
14,400 / ∞
0298xxx.ZXH
300 - 500
500
None
M8
2
100
14,400 / ∞
–/–
0298xxx.UX1M8 80 - 500
500
None
M8
1
135
120 / 1800
–/–
0298xxx.ZXB
40 - 250
500
Ag
M8
2
200
1 / 15
1 / 15
0298xxx.ZXA
80 - 500
500
None
M6
2
350
0.3 / 5
0.5 / 5
600
0.1 / 1
0.1 / 1
MEGA Clear Top Housing Material Fuse
0298xxx.UXT
10
% of
Rating
Part Number
60A
80A
100A
125A
150A
175A
200A
225A
250A
300A
TIME-CURRENT CHARACTERISTIC CURVES (RECORDED@23°C)
Voltage Rating:
32 VDC
Interrupting Rating:
2000A @ 32 VDC
Recommended Environmental Temperature: -40˚C to + 125˚C
Terminals Materials: Copper (Silver plated copper available)
Housing Material:
PPA-GF33HS (U.L. 94 Flammability rating - HB)
Clear Top Housing Material:
PES (top) (U.L. 94 Flammability rating - V0)
PPA-GF33HS (bottom) (U.L. 94 Flammability rating - HB)
Mounting Torque M6:
8-14 Nm
Mounting Torque M8:
12-18 Nm
Complies with:
ISO 8820-5
40 - 250
500
None
M8
2
Ratings
1
0.1
0.01
10
100
1000
10000
10000
400A
450A
500A
350A
CURRENT [A]
1000
TIME [s]
100
10
1
0.1
100
1000
CURRENT [A]
REV07272021
10000
Part Number
Current
Rating (A)
Color Code 3 Test Cable Size Typ. Voltage
(mm2)
Drop (mV)
0298040._1
40
–
1
0298060._
60
–
0298080._
80
0298100._
100
0298125._
125
0298150._
Typ. Cold
Resistance (mΩ)
Typ. I2t
(A2s)
4
132
2.51
8,700
6
119
1.50
21,000
10
87
0.72
21,500
16
87
0.56
31,100
16
80
0.42
57,800
150
25
92
0.35
100,000
0298175._
175
25
86
0.29
168,000
0298200._
200
35
83
0.26
204,000
0298225._
225
35
82
0.22
257,000
0298250._
250
50
82
0.20
389,000
0298300._2
300
70
74 4
0.17
315,000
0298350._2
350
70
68 4
0.14
500,000
2
0298400._
400
70
64
4
0.13
610,000
0298450._2
450
70
60 4
0.11
1,050,000
0298500._2
500
70
58 4
0.09
2,050,000
1: Not mentioned in ISO standards
2: Short Circuit Protector only
3: 0298xxx.ZXB has white font color on all ratings.
4: Voltage Drop measurements for short circuit protectors taken at 75% of rated current.
The typical I2t is an average value calculated from the breaking capacity tests by using the melting time before the arcing occurs.
®
Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for
surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse ®
product documentation. Warranties granted by Littelfuse ® shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse ® documentation. Littelfuse ® shall not be liable for any claims or
damages arising out of products used in applications not expressly intended by Littelfuse ® as set forth in applicable Littelfuse ® documentation. The sale and use of Littelfuse ® products is subject to Littelfuse Terms and Conditions of
Sale, unless otherwise agreed by Littelfuse ®.
33
littelfuse.com
High Current Fuses
MEGA® Fuse Rated 32V
Dimensions
Dimensions in mm for reference only.
See outline drawing for dimensions and tolerances.
ZX & UXT Versions
UX1M8 Version
68.6
50.8
29.2
(25.4)
XXXAMP
19.0
16.3
M6: Ø6.6
M8: Ø8.6
XXXA
9.9 (40A-250A)
10.7 (300A-500A)
1.02 (40A-250A)
1.8 (300A-500A)
Typical Derating
Temperature Table
Temperature Security Margin is 20%
Please contact Littelfuse® for Details Regarding Derating Test Set-Up.
max. allowed current load [A] at ambient temperature
40A
60A
80A
100A
125A
150A
175A
200A
225A
250A
300A
350A
400A
450A
500A
Max Recommended
Environmental
Temperature
Derating curves may change depending on the final condition of the application (terminals characteristics, wire
size etc..).
Please ask Littelfuse for more information.
-20°C
0°C
20°C
65°C
85°C
95°C
105°C
125°C
35
48
81
101
129
149
164
184
194
230
272
311
317
337
378
33
46
76
95
123
141
156
175
184
218
258
294
300
320
358
31
43
72
90
116
133
147
165
174
205
242
277
283
302
337
26
36
61
76
98
112
124
139
147
173
204
232
239
256
284
23
32
55
69
88
102
112
126
134
157
184
209
216
232
257
22
30
52
65
83
96
106
119
127
147
174
197
204
219
242
20
28
49
61
78
90
99
112
119
138
162
184
191
206
227
17
23
41
51
66
76
84
94
101
116
136
154
161
175
191
REV07272021
Littelfuse ® products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for
surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse ®
product documentation. Warranties granted by Littelfuse ® shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse ® documentation. Littelfuse ® shall not be liable for any claims or
damages arising out of products used in applications not expressly intended by Littelfuse ® as set forth in applicable Littelfuse ® documentation. The sale and use of Littelfuse ® products is subject to Littelfuse Terms and Conditions of
Sale, unless otherwise agreed by Littelfuse ®.
34