Special Application Fuses
PICO® 304 Series Fuses > 277V UL913 Intrinsically Safe Fuse
PICO® 304 Series – 277V UL913 Intrinsically Safe Fuse
RoHS
Description
Features
Agency
• High Interrupting Rating of • Designed for operation
1500A
in a range of hazardous
environments
• Well suited for 277V
application
• Encapsulated and sealed
(1mm minimum)
• Current rating options
from 0.050 to 0.750A
• Surface Mount Device
IN
A
Agency Approvals
Agency File Number
Ampere Rating
DEMKO 13 ATEX 1200U
50 - 750mA
E358130
50 - 750mA
IECEx UL 13.0077U
50 - 750mA
Applications
• Testing, measuring or
• Process control and
processing electronic and
automation
electrical equipment
• Sensors
• Motor controllers
• Lighting
IM
Reference Standards
Agency
RY
The PICO® 304 Series offers a range of suface mountable
encapsulated fuses certified under UL 913, the standard
for intrinsically safe electrical equipment, to operate in
hazardous locations. Ideal for use in oil, gas, mine, chemical,
and pharmaceutical industries, the PICO 304 Series surface
mountable fuse was designed to limit the energy and
temperature generated during its operation. The fuse design
and its encapsulant are suitable for use in an intrinsically
safe apparatus and associated apparatus for peak voltage not
exceeding 375V.
Standards
• Communication handsets/ • Flow/gas meters
two-way radios
EN 60079-0, EN 60079-11,
EN 60079-26
IECEx
IEC 60079-0, IEC 60079-11,
IEC 60079-26
UL
UL 913, UL 60079-0,
UL 60079-11
% of Ampere
Rating
CAN/CSA C22.2 No. 157,
CAN/CSA C22.2 No. 60079-0,
CAN/CSA C22.2 No. 60079-11
110%
4 Hours, Minimum
300%
10 Seconds, Maximum
cUL
EL
ATEX
Electrical Characteristics for Series
Opening Time
Electrical Specifications by Items
Ampere
Rating
(A)
Amp
Code
Nominal
Melting
I2t (A2 Sec.)
Minimum Cold
Resistance at
-20°C (Ohms)
0304.050
0.050
0304.080
0.080
.050
0.00019
.080
0.00035
0304.100
0.100
.100
0304.160
0.160
.160
0304.200
0.200
.200
0304.250
0.250
.250
0304.500
0.500
0304.750
0.750
Agency Approvals
Minimum Cold
Resistance at
-40°C (Ohms)
Nominal Cold
Resistance at
25°C (Ohms)
9.202
9.010
12.00
X
X
X
6.031
5.963
8.19
X
X
X
0.00070
2.709
2.668
5.00
X
X
X
0.00202
2.297
2.292
3.00
X
X
X
0.00288
1.935
1.839
2.68
X
X
X
0.00662
1.268
1.105
1.60
X
X
X
.500
0.04462
0.392
0.368
0.46
X
X
X
.750
0.13448
0.219
0.196
0.27
X
X
X
Interrupting
Rating
PR
Catalog
Number
1500A @
277VAC/DC
Notes: 1) The fuse must be mounted so that creepage and clearance distances are not impaired in any way.
2) The fuse is suitable for use in intrinsically safe equipment and associated apparatus for voltage not exceeding 375V peak.
3) Maximum surface temperature rise at 170% rated current: ≤200mA = 88°C, 250mA = 52°C, 500mA = 52°C, and 750mA = 45°C.
© 2017 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 02/22/17
Special Application Fuses
PICO® 304 Series Fuses > 277V UL913 Intrinsically Safe Fuse
-40ºC to +60ºC
-40ºC to +56ºC
-40ºC to +84ºC
0.750A
-40ºC to +56ºC
1) Any use of the 304 Series fuse outside of the ambient temperature ranges specified in
the table is subject to additional investigation.
Thermal Shock
Withstands 5 cycles of –55°C to
125°C
Vibration
Per MIL-STD-202
Insulation Resistance
(After Opening)
Greater than 10,000 ohms
(at twice rated DC voltage)
10
TIME IN SECONDS
Note:
IN
A
RY
0.250A
0.500A
100
.750A
Ambient Temperature
≤0.200A
.050A
Operating Temperature
Current Rating
.500A
Average Time Current Curves
.080A
.100A
.160A
.200A
.250A
Product Characteristics
1
0.1
0.01
0.001
Reflow Condition
Pre Heat
- Temperature Min (Ts(min))
150°C
- Temperature Max (Ts(max))
- Time (Min to Max) (ts)
200°C
60 - 120 seconds
5°C/second max
EL
Average Ramp-up Rate
(Liquidus Temp (TL) to peak)
TS(max) to TL - Ramp-up Rate
Reflow
Pb-free assembly
- Temperature (TL) (Liquidus)
- Temperature (tL)
5°C/second max
217°C
60 - 90 seconds
260+0/-5°C
Time within 5°C of
actual peak Temperature (tp)
20 -40 seconds
Ramp-down Rate
5°C/second max
Time 25°C to Peak Temperature (TP)
8 minutes max
Do not exceed
260°C
Wave Soldering
260°C, 10 sec. max
PR
Peak Temperature (TP)
0.01
1
10
CURRENT IN AMPERES
0.1
100
1000
tP
TP
Critical Zone
TL to TP
Ramp-up
TL
tL
TS(max)
Temperature
Soldering Parameters
IM
0.0001
Ramp-down
TS(min)
25
Preheat
tS
time to peak temperature
(t 25ºC to peak)
Time
© 2017 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 02/22/17
Special Application Fuses
PICO® 304 Series Fuses > 277V UL913 Intrinsically Safe Fuse
Dimensions (mm)
Temperature Rerating Curve
140
120
IN
A
RY
6.09 ± 0.10
13.67 ± 0.10
PERCENT OF RATING
2.91 ± 0.10
6.03 ± 0.10
LF Phils. 2017
304.XXX UL913 277V
II 1 G Ex ia IIC
IECEx UL 13.0077U
DEMKO 13 ATEX 1200U
100
80
60
25˚C
40
0.10 Max.
20
1.37± 0.10
10.90± 0.20
2.00± 0.10
-60
-40
-20
0
20
40
60
80
100
AMBIENT TEMPERATURE (˚C)
Note:
3.00
RECOMMENDED PAD LAYOUT
1) Rerating depicted in this curve is in addition to the standard rerating of 25% for
continuous operation.
Part Numbering System
0304 .050 Z R
11.20
EL
IM
1.70
SERIES
AMP CODE
Refer to Electrical
Specifications table
QUANTITY CODE
Z = 800 pcs
H = 100 pcs
PACKAGING CODE
R = Tape and Reel
Packaging
Packaging Specification
24mm Tape and Reel
EIA 481-1
PR
Packaging Option
© 2017 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 02/22/17
Quantity
Quantity &
Packaging Code
800
ZR
100
HR
120
很抱歉,暂时无法提供与“0304.750HR”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+207.225811+25.11805
- 5+197.356535+23.92179
- 10+182.5515710+22.12727
- 50+157.8846050+19.13736