Blade Fuses
MICRO2™ Blade Fuses Rated 32V
The MICRO2™ Fuse is the new standard for vehicle circuit protection. Its sub-miniature
design meets the need for more circuits to be protected while utilizing less space and its
ability to cope with high temperatures in adverse environments makes the MICRO2™ Fuse of
recommended choice for protection.
Black amperage stamps are used on the 20A & 25A / light colored housings to improve
contrast for vision system inspection.
Specifications
MICRO2 TM Blade Fuses
Voltage Rating:
MICRO2
(Silver Plated)
32 VDC
MICRO2 Sn
(Tin Plated)
32 VDC
Interrupting Ratings:
1000A @ 32 VDC
1000A @ 32 VDC
*Component Level Temperature Range:
**System Level Temperature Range:
-40˚C to +125˚C
-40˚C to +105˚C
-40˚C to +105˚C
-40˚C to +85˚C
105°C and 85°C are typical system level temperature requirements.
Terminals:
Ag plated zinc alloy
Housing Material:
Conforms to:
PA66
PA66
SAE 2741 and ISO 8820-3 in reference to electrical, mechanical
and environmental performance requirements
Ordering Information
Part Number
MICRO2 TM Sn
(Tin plated) Blade Fuses
Time-Current Characteristics
Package Size
% of Rating
MICRO2 (Silver Plated)
110
100 h / –
4000
135
0.75 sec / 120 sec
0327xxx.UXS
500
160
0.30 sec / 50 sec
0327xxx.LXS
50
200
0.15 sec / 5 sec
0327xxx.YX2T
4000
350
0.04 sec / 0.50 sec
600
0.02 sec / 0.100 sec
Ratings
Dimensions in mm
Typ. Voltage Drop
(mV)
Cold Resistance
(mΩ)
I2t
(A2s)
3 (*)
113
31.7
9
0327005._
5
116
17.4
17
032707.5_
7.5
106
10.8
47
0327010._
10
102
7.7
89
0327015._
15
94
4.9
189
0327020._
20
91
3.5
397
0327025._
25
90
2.6
585
0327030._
30
88
2.1
1028
Part Number
0327003._
Temperature Rerating Curve
Opening Time Min / Max
0327xxx.YX2S
MICRO2 Sn (Tin Plated)
Dimensions
Sn plated zinc alloy
Current Rating
Housing
(A)
Material Color
* 3 A rating is available
only as Ag Plated version
MICRO2 Fuse Time-Current Characteristics
Time-Current Characteristic Curves
1000.
100.
3
10.
5
Time (s)
7.5
10
15
20
1.
25
30
0.1
0.01
REV11212019
1
10
100
*Component Level Temperature =
the maximum ambient temperature
that a single fuse will survive. This
does not factor-in the heat from a
populated fuse box, but does include
the heat from the current load with
the proper rerating. **System Level
Temperature represents the ambient
temperature of the fuse box at a
location within the vehicle. The
temperature within a populated fuse
box (in a given location) will be
higher. The limiting factor is the
plating. Sn-plating’s temperature
limit is ≈130°C, and Ag-plating
allows up to 150°C at the terminal
interface.
1000
Current (A)
Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for
surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse
product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages
arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless
otherwise agreed by Littelfuse.
2
littelfuse.com
很抱歉,暂时无法提供与“0327020.YX2T”相匹配的价格&库存,您可以联系我们找货
免费人工找货