Axial Lead & Cartridge Fuses
5×20 mm > Time-Lag > 477 Series
477 Series, 5×20 mm, Time-Lag Fuse
RoHS Pb
PS
E
Description
400Vdc/500Vac rated, 5x20mm, time-lag, surge withstand
ceramic body cartridge fuse.
Features
• Designed to International
(IEC) Standard for use
globally.
• Follow the IEC 60127-2,
Sheet 5 specification for
time-lag fuses
Agency Approvals
• Available in cartridge and
axial lead form
• RoHS compliant and
lead-free
Applications
Agency
PS
E
Agency File Number
Cartridge:
NBK040609-JP1021A
NBK040609-JP1021C
NBK100408-JP1021A
Leaded:
NBK040609-JP1021B
NBK040609-JP1021D
NBK100408-JP1021B
Ampere Range
1A – 5A
6.3A – 12A
16A
High energy and power efficient applications.
Electrical Characteristics for Series
1A – 5A
6.3A – 12A
16A
% of Ampere
Rating
1620077
0.500A – 8A
150%
E10480
0.500A - 16A
40025413
1A, 3.15A
J50248089
10A, 12A, 16A
N/A
0.500A – 16A
210%
275%
Additional Information
400%
Datasheet
Resources
Samples
1000%
Ampere Rating
Opening Time
.5 - .8
1 - 3.15
4 - 6.3
8 - 16
.5 - .8
1 - 3.15
4 - 6.3
8 - 16
.5 - .8
1 - 3.15
4 - 6.3
8 - 16
.5 - .8
1 - 3.15
4 - 6.3
8 - 16
.5 - .8
1 - 3.15
4 - 6.3
8 - 16
60 minutes, Minimum
60 minutes, Minimum
60 minutes, Minimum
30 minutes, Minimum
30 minutes, Maximum
30 minutes, Maximum
30 minutes, Maximum
30 minutes, Maximum
.25 sec., Min.; 80 sec. Max.
.75 sec., Min.; 80 sec. Max.
.75 sec., Min.; 80 sec. Max.
.75 sec., Min.; 80 sec. Max.
.05 sec., Min.; 5 sec. Max.
.095 sec., Min.; 5 sec. Max.
.15 sec., Min.; 5 sec. Max.
.15 sec., Min.; 5 sec. Max.
.005 sec., Min.; .15 sec. Max.
.01 sec., Min.; .15 sec. Max.
.01 sec., Min.; .15 sec. Max.
.01 sec., Min.; .15 sec. Max.
© 2020 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: BA.09/16/20
Axial Lead & Cartridge Fuses
5×20 mm > Time-Lag > 477 Series
Electrical Characteristic
Max Voltage
Rating (V)
Amp
Code
Amp
Rating
.500
.800
001.
002.
3.15
004.
005.
06.3
008.
010.
012.
0.5
0.8
1
2
3.15
4
5
6.3
8
10
12
AC
500
500
500
500
500
500
500
500
500
500
500
DC
400
400
400
400
400
400
400
400
400
400
400
016.
16
500
400
Interrupting Rating
100A@500VAC
1500A@400VDC
100A@500VAC
500A@400VDC
100A@500VAC
400A@400VDC
Agency Approvals
Nominal Cold
Resistance
(Milli-ohms)
Nominal
Melting
2
I t (A2 sec.)†
PS
E
1055.900
430.000
139.400
55.200
27.700
17.200
13.700
10.970
8.305
4.950
4.730
0.300
0.909
1.800
9.120
50.109
52.480
76.500
121.451
203.520
509.000
576.000
x
x
x
x
x
x
x
x
x
x*
x*
x*
x*
x*
x*
x*
x
x
x
x
x**
x**
x**
x**
x**
x**
x**
x**
x**
-
x
x
x
x
-
3.100
1331.200
x
x
-
x***
-
*100A @ 600Vac also available. Add suffix "MXE6P". Example: 0477004.MXE6P.
**Semko approval for 100A@500Vac and 200A@400Vdc.
***100A@ 500Vac and 300A@400Vdc for 16A
†2
I t test at 10x rated current.
10A
12A
16A
3.15A
4A
5A
6.3A
8A
2A
0.800A
1A
Average Time Current Curves
0.500A
Temperature Re-rating Curve
© 2020 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: BA.09/16/20
Axial Lead & Cartridge Fuses
5×20 mm > Time-Lag > 477 Series
Soldering Parameters - Wave Soldering
Recommended Process Parameters:
280
Wave Parameter
Lead-Free Recommendation
(Depends on Flux Activation Temperature)
(Typical Industry Recommendation)
260
240
Preheat:
220
200
180
160
140
Temperature Minimum:
100°C
Temperature Maximum:
150°C
Preheat Time:
120
100
60-180 seconds
Solder Pot Temperature:
80
260°C Maximum
Solder Dwell Time:
60
40
240
230
220
210
200
190
180
170
160
150
140
130
120
110
90
100
80
70
60
50
40
30
20
10
0
2-5 seconds
Recommended Hand-Solder Parameters:
Solder Iron Temperature: 350°C +/- 5°C
Heating Time: 5 seconds max.
Note: These devices are not recommended for IR or Convection Reflow process.
20
0
Temperature (°C) - Measured on bottom side of board
300
Time (Seconds)
Cooling Time
Preheat Time
Dwell Time
Product Characteristics
Body: Ceramic
Cap: Nickel–plated Brass
Leads: Tin–plated Copper
MIL-STD-202, Method 211, Test Condition A
Materials
Terminal Strength
Operating Temperature
Thermal Shock
Vibration
MIL-STD-202 Method 208
Cap 1: Brand logo, current and voltage ratings
Cap 2: Series and agency approval markings
Available in Bulk (M=1000 pcs/pkg)
Solderability
Product Marking
Packaging
Dimensions
–55ºC to +125ºC
MIL-STD-202, Method 107, Test Condition B (5
cycles, –65ºC to +125ºC)
MIL-STD-202, Method 201
Humidity
MIL-STD-202, Method 103, Test Condition A
(High RH (95%) and elevated temp (40ºC) for
240 hours)
Salt Spray
MIL-STD-202, Method 101, Test Condition B
Part Numbering System
0477 xxxx M X E P
0477000XP
Series
Amp Code
0477.500XEP
to
0477.800XEP
40±1.0
Refer to Amp Code Column of
Electral Characteristics Table
5.6±0.4
21.5±1.0
Quantity Code
M = 1000
0.65±0.05*
0477001.XEP
to
0477016.XEP
Packing Code
40±1.0
X = Filler
5.5±0.3
21.5±1.0
Option Code
E: Axial Lead
Others: Special Options
Please Call Littelfuse for detail.
0.65±0.05*
All dimensions in mm
Notes:
* Ratings above 5A 1.0±0.05 diameter lead.
Lead-Free
Packaging
Quantity &
Packaging Code
Reel Size
1000
MX
N/A
N/A
1000
MXE
N/A
N/A
1000
MRET1
T1=53mm (2.087”)
Packaging Option
Packaging Specification
Quantity
Bulk
N/A
Bulk
Reel and Tape
477 Series
Disclaimer Notice - Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications,
devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth
in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable
for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and
Conditions of Sale, unless otherwise agreed by Littelfuse. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own
applications. Littelfuse products are not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at www.littelfuse.com/disclaimer-electronics.
© 2020 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: BA.09/16/20