GAS DISCHARGE TUBES (GDTS)
Littelfuse's GDTs (Gas Discharge Tubes) are placed in
front of, and in parallel with, sensitive telecom equipment
such as power lines, communication lines, signal lines
and data transmission lines to help protect them from
damage caused by transient surge voltages that may
result from lightning strikes and equipment switching
operations. These devices do not influence the signal in
normal operation. However, in the event of an overvoltage
surge, such as a lightning strike, the GDT switches to a low
impedance state and diverts the energy away from the
sensitive equipment.
Our GDTs offer a high level of surge protection, a broad
voltage range, low capacitance, and many form factors
including new surface mount devices, which makes them
suitable for applications such as Main Distribution Frame
(MDF) modules, high data-rate telecom applications (e.g.
ADSL, VDSL), and surge protection on power lines. Their low capacitance also results in less signal distortion. When
used in a coordinated circuit protection solution with PolySwitch devices, they can help equipment manufacturers meet
stringent safety regulatory standards.
BENEFITS
APPLICATIONS
• Helps provide overvoltage fault protection against
damage caused by high energy surges
• Suitable for use in sensitive equipment due to
impulse sparkover response
• Suitable for high-frequency applications
• Highly reliable performance
• Telecommunications
- MDF modules, xDSL equipment, RF systems,
antenna, base stations
• Industrial and Consumer Electronics
- Power supplies, surge protectors, alarm systems,
irrigation systems
• New surface-mount devices for automated
manufacturing
FEATURES
• RoHS compliant
• Devices tested per ITU K.12 recommendations
• Halogen free
(refers to: Br≥900ppm, Cl≥900ppm, Br+Cl≥1500ppm)
• Various lead configurations and surface-mount
options
• Wide range of voltages (75V-4000V)
• Optional fail-short mechanism
• Wide range of form factors
(3mm, 5mm, 6mm, 7mm, 8mm diameter devices)
• Non radioactive materials
• Devices certified to UL497B and UL1449
• Low capacitance and insertion loss
• Crowbar device with low arc voltage
• High accuracy spark-over voltages for high precision
designs
RoHS Compliant, ELV Compliant
Specifications subject to change without notice. ©2016 Littelfuse, Inc.
73
Gas Discharge Tubes (GDTs)
Figures G1-G2 — Typical Circuits for Gas Discharge Tubes
Figure G1
Figure G2
Two
Two
Electrode
Electrode
Devices
Devices
forfor
Ungrounded
Ungrounded
Circuits
Circuits
PolySwitch
PolySwitch
Device
Device
(A) (A)
Telecom
Telecom
LineLine
Three
Three
Electrode
Electrode
Devices
Devices
forfor
Grounded
Grounded
Circuits
Circuits
Protected
Protected
Equipment
Equipment
GDTGDT
(B) (B)
PolySwitch
PolySwitch
Device
Device
(A) (A)
(A’)(A’)
Telecom
Telecom
LineLine
(B’)(B’)
Thyristor
Thyristor
(A’)(A’)
Protected
Protected
Equipment
Equipment
GDTGDT
(B) (B)
(B’)(B’)
Thyristors
Thyristors
PolySwitch
PolySwitch
Device
Device
Table G1 — Device Voltage Ratings, Surge Rating, Capacitance, Insulation Resistance
and Agency Approval for Two-Electrode Gas Discharge Tubes
DC
Sparkover
Voltage
Part Number
Impulse
Sparkover
Voltage
@ 100V/s
± 20% Tolerance
@ 1kV/μs
75*
600
90
600
140
600
GTCS23-XXXM-R01-2
GTCC23-XXXM-R01-2
150
600
200
700
230
700
300
900
350
1000
400
1000
Impulse
Discharge Current
Impulse
Withstanding
Voltage
Capacitance
Insulation
Resistance
UL Rating
8x20μs
10 Hits
(5 Hits Each
Polarity)
8x20μs
300 Hits
(150 Hits Each
Polarity)
10/700μs
10 Hits
(5 Times Each
Polarity)
@1MHz
@100VDC†
1kA
100A
4kV
很抱歉,暂时无法提供与“GTCS25-301M-R02-2”相匹配的价格&库存,您可以联系我们找货