Gas Discharge Tubes
High Performance Beta Range
RoHS
Greentube™ HV Series Gas Plasma Arresters
®
The HV Series is a 2-terminal bi-directional, voltage triggered
switch designed for the protection of high voltage circuits.
Switching voltages for the devices are fixed depending on the
part number selected. The gas plasma trigger technology offers
very fast switching speeds, high current capability and very low
leakage currents.
Features
• 2 terminal configuration.
pr
od
uc OB
th S
as OL
be ET
en E:
di
sc
on
tin
ue
d
• Very high Isolation up to the specified switching voltage.
• Switching performance is virtually unaffected by changes in
ambient temperature.
• UL 1414 class Y2 rated. Listed under file number E56529.
• Moisture resistance as per MIL-STD-202 method 106
Applications
8
+0.20
- 0.20
8
+0.20
- 0.20
0.8
+0.050
- 0.050
• To protect of high voltage circuits.
• To provide isolation between chassis and ground.
8
+0.20
- 0.20
60.0
+4
Th
is
HV XXX A
8
+0.20
- 0.20
60.0
+4
HV XXX C
ORDERING INFORMATION
HV 275
Mechanical Specifications:
Weight:
Materials:
Voltage (x10)
Lead Form
Device Marking:
1.42g (0.049oz.)
Electrode Base: Copper alloy
Electrode Plating material: Bright Sn
Body: Ceramic
Littelfuse ‘LF’ marking, voltage and
product code
A= Axial lead, tape & reel
C= Core
w w w. l i t t e l f u s e . c o m
8
GAS DISCHARGE
TUBES
(90-98%RH, 65˚C).
• Tape and reel to EIA 481-1.
351
Gas Discharge Tubes
Gas Plasma Voltage Dependent Switches
RoHS
Greentube™ HV Series Gas Plasma Arresters
Device Ratings and Specifications
DC Breakover Voltage (VBO) (1)
Insulation Resistance (RS) (2)
Max Capacitance (Co) (3)
2850 – 3500 V
Max Impulse Breakover Voltage (IBO) (5)
3700 V
100 M1
1.0 pF
Maximum Ratings:
pr
od
uc OB
th S
as OL
be ET
en E:
di
sc
on
tin
ue
d
Impulse Discharge Current (4) …………………………………………………… 3 kA, 10 shots
Storage Temperature TSTG ……………………………………………………… -40 - +150˚C
Operating Temperature
……………………………………………………… -40 - +150˚C
Notes:
(1) Measured @ 500 Volts / Second
(2) Measured @ 1000 Volts DC
(3) Measured @ 1 MHz, zero Volt bias
(4) Using 8/20µs double exponential pulse
Th
is
(5) Measured at 100 Volts/µs rate of rise
352
w w w. l i t t e l f u s e . c o m
®