Thyristors
4 Amp Sensitive & Standard Triacs
Lxx04xx & Qxx04xx Series
RoHS
Description
The Lxx04xx and Qxx04xx are 4 Amp bidirectional solid
state switch series. They are designed for AC switching
and phase control applications such as motor speed and
temperature modulation controls, lighting controls, and
static switching relays.
Sensitive type devices guarantee gate control in Quadrants
I & IV as needed for digital control circuitry.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Features & Benefits
• Restricted (or limited) RFI
generation, depending on
activation point of
sine wave
• Surge capability up to
55 A
Agency Approval
Agency
• The L-package has
an isolation rating of
2500VRMS
Agency File Number
E71639
• Solid-state switching
eliminates arcing or
contact bounce that
create voltage transients
Main Features
Symbol
Value
Unit
IT(RMS)
4
A
VDRM / VRRM
400, 600, 800 or 1000
V
IGT (Q1)
3 to 25
mA
• Requires only a short gate
activation pulse in each
half-cycle
• RoHS-compliant
• Glass – passivated
junctions
• No contacts to wear out
from reaction of switching
events
Notes:
- L Package only.
- 400V and 600V for Sensitive Triac (L Device Type)
- 400V, 600V, 800V, or 1000V for Standard Triac (Q Device Type)
• Voltage capability up to
1000 V
Applications
Typical applications are AC solid-state switches, power
tools, home/brown goods and white goods appliances.
Schematic Symbol
Sensitive gate Triacs can be directly driven by
microprocessor or popular opto-couplers/isolators.
MT2
MT1
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
G
Absolute Maximum Ratings — Sensitive Triacs (4 Quadrants)
Symbol
Parameter
RMS on-state current
(full sine wave)
IT(RMS)
ITSM
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
Lxx04Ly
Value
Unit
4
A
TC = 90°C
Lxx04Vy/Lxx04Dy
TC = 95°C
Lxx04Ry
TC = 100°C
f = 50 Hz
t = 20 ms
33
f = 60 Hz
t = 16.7 ms
40
A
I2t
I2t Value for fusing
di/dt
Critical rate of rise of on-state current
(IG = 50mA with ≤ 0.1μs rise time)
f = 120 Hz
IGTM
Peak gate trigger current
tp=20μs
TJ = 110°C
4
A
PG(AV)
Average gate power dissipation
-
TJ = 110°C
0.3
W
Tstg
Storage temperature range
-
-
-40 to 150
°C
TJ
Operating junction temperature range
-
-
-40 to 110
°C
tp = 8.3 ms
TJ = 110°C
6.6
A2s
50
A/μs
Note: xx = voltage/10, y = sensitivity
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Absolute Maximum Ratings — Standard Triacs
Symbol
Parameter
IT(RMS)
RMS on-state current
(full sine wave)
ITSM
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
Qxx04Ly
TC = 100°C
Qxx04Vy/Qxx04Dy
TC = 110°C
Qxx04Ry
TC = 115°C
Value
Unit
4
A
f = 50 Hz
t = 20 ms
46
f = 60 Hz
t = 16.7 ms
55
I2t
I2t Value for fusing
di/dt
Critical rate of rise of on-state current
(IG = 50mA with ≤ 0.1μs rise time)
f = 120 Hz
IGTM
Peak gate trigger current
tp=20μs
PG(AV)
Average gate power dissipation
tp = 8.3 ms
TJ = 125°C
A
12.5
A2s
50
A/μs
TJ = 125°C
4
A
TJ = 125°C
0.3
W
Tstg
Storage temperature range
-40 to 150
°C
TJ
Operating junction temperature range
-40 to 125
°C
Note: xx = voltage/10, y = sensitivity
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Sensitive Triac (4 Quadrants)
Symbol
Test Conditions
IGT
VD = 12V RL = 60 Ω
Quadrant
I – II – III
IV
MAX.
Lxx04x3
Lxx04x5
Lxx04x6
3
5
5
10
3
5
10
20
VGT
VD = 12V RL = 60 Ω
ALL
MAX.
1.3
VGD
VD = VDRM RL = 3.3 kΩ TJ = 110°C
ALL
MIN.
0.2
IH
dv/dt
IT = 100mA
MAX.
400V
VD = VDRM Gate Open TJ = 100°C
600V
TYP.
Lxx04x8
Unit
mA
V
V
5
10
10
15
25
25
30
35
15
15
20
25
mA
V/μs
(dv/dt)c
(di/dt)c = 2.16 A/ms TJ = 110°C
TYP.
0.5
1
1
1
V/μs
tgt
IG = 2 x IGT PW = 15μs IT = 5.6 A(pk)
TYP.
2.8
3.0
3.0
3.2
μs
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Standard Triac
Symbol
Test Conditions
IGT
VD = 12V RL = 60 Ω
Quadrant
Qxx04x3
Qxx04x4
I – II – III
MAX.
10
25
IV
TYP.
25
50
Unit
mA
VGT
VD = 12V RL = 60 Ω
I – II – III
MAX.
1.3
1.3
VGD
VD = VDRM RL = 3.3 kΩ TJ = 125°C
ALL
MIN.
0.2
0.2
V
IH
IT = 200mA
MAX.
20
30
mA
400V
40
75
600V
30
50
dv/dt
VD = VDRM Gate Open TJ = 125°C
800V
VD = VDRM Gate Open TJ = 100°C
(dv/dt)c
IG = 2 x IGT PW = 15μs IT = 5.6 A(pk)
VD = 2/3 VDRM Gate Open TJ = 125°C
40
1000V
(di/dt)c = 2.16 A/ms TJ = 125°C
tgt
dv/dt
MIN.
800V
V
V/μs
50
TYP.
2
2
V/μs
TYP.
2.5
3.0
μs
40
-
V/μs
Note: xx = voltage/10, x = package
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Static Characteristics (TJ = 25°C, unless otherwise specified)
Symbol
Test Conditions
VTM
ITM = 5.6A tp = 380 µs
MAX.
Lxx04xy
IDRM
VDRM = VRRM
IRRM
MAX.
Qxx04xy
Value
Unit
1.60
V
TJ = 25°C
400-600V
5
μA
TJ = 110°C
400-600V
200
μA
μA
TJ = 25°C
400-1000V
10
TJ = 125°C
400-800V
2
TJ = 100°C
1000V
3
mA
Thermal Resistances
Symbol
Parameter
RƟ(J-C)
Junction to case (AC)
RƟ(J-A)
Junction to ambient
Value
L/Qxx04Dy
L/Qxx04Ly
L/Qxx04Ry
L/Qxx04Vy
L/Qxx04Ly
L/Qxx04Ry
L/Qxx04Vy
Unit
1.5
3.0
1.1
1.5
50
45
70
°C/W
°C/W
Note: xx = voltage/10, x = package, y = sensitivity
Figure 2: N
ormalized DC Gate Trigger Current for
All Quadrants vs. Junction Temperature
Figure 1: Definition of Quadrants
ALL POLARITIES ARE REFERENCED TO MT1
(+)
IGT
GATE
MT1
IGT
MT1
REF
IGT
GATE
(+)
+
IGT
MT2
3.0
2.0
1.0
IGT
GATE
0.0
MT1
REF
REF
QII QI
QIII QIV
MT2
(-)
IGT
IGT
GATE
MT2
IGT (TJ = 25°C)
(-)
+
4.0
Ratio of
MT2
MT2 POSITIVE
(Positive Half Cycle)
-
MT2 NEGATIVE
(Negative Half Cycle)
MT1
-65
-40
-40
10
35
60
85
110
125
Junction Temperature (TJ)- ºC
REF
Additional Information
Datasheet
Resources
Samples
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Figure 3: Normalized DC Holding Current
vs. Junction Temperature
Figure 4: N
ormalized DC Gate Trigger Voltage for
All Quadrants vs. Junction Temperature
2.0
2.0
VGT (TJ = 25°C)
VGT
3.0
1.5
1.0
Ratio of
IH
Ratio of
IH (TJ = 25°C)
4.0
1.0
0.5
0.0
0.0
-65
-40
-40
10
35
60
85
110
-65
125
-40
-40
Junction Temperature (TJ)- ºC
60
85
110
125
Figure 6: M
aximum Allowable Case Temperature
vs. On-State Current
4.0
125
Qxx04Vy
Qxx04Dy
120
Maximum Allowable
Case Temperature (TC) - °C
CURRENT WAVE FORM: Sinusoidal
3.0
35
Junction Temperature (TJ)- ºC
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
Average On-State
Power Dissipation (PD(AV)) - Watts
10
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
2.0
1.0
Qxx04Ry
115
110
105
100
Qxx04Ly
95
CURRENT WAVE FORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured
as shown on Dimensional Drawing
90
85
80
0.0
0.0
1.0
2.0
3.0
4.0
75
5.0
0
RMS On-State Current (IT(RMS)) - Amps
2
3
Maximum Allowable
Ambient Temperature (TA) - °C
Maximum Allowable
Case Temperature (TC) - °C
Lxx04Vy
Lxx04Dy
Lxx04Ly
90
85
80
CURRENT WAVE FORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured
as shown on Dimensional Drawing
75
70
65
6
120
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
FREE AIR RATING – NO HEATSINK
105
95
5
Figure 8: Maximum Allowable Ambient Temperature
vs. On-State Current
Lxx04Ry
100
4
RMS On-State Current (IT(RMS)) - Amps
Figure 7: Maximum Allowable Case Temperature
vs. On-State Current
110
1
100
80
Qxx04Ly
Qxx04Ry
60
L/Qxx04Vy
40
Lxx04Ly
20
60
0
1
2
3
4
RMS On-State Current (IT(RMS)) - Amps
5
6
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RMS On-State Current [IT(RMS)] - Amps
Note: xx = voltage/10, y = sensitivity
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Figure 9: On-State Current vs. On-State Voltage (Typical)
20
TJ = 25°C
Positive or Instantaneous
On-State Current (IT) - Amps
18
16
14
12
10
8
6
4
2
0
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Positive or Instantaneous
On-State Voltage (VT) - Volts
Figure 10: Surge Peak On-State Current vs. Number of Cycles
Peak Surge (Non-repetitive) On-State Current
(ITSM) – Amps
100
Supply Frequency: 60Hz Sinusoidal
Load: Resistive
RMS On-State [IT(RMS)]: Max Rated Value at
Specific Case Temperature
Qxx04Ry
Qxx04Ly
Qxx04Dy
Qxx04Vy
Notes:
1. G
ate control may be lost during and immediately
following surge current interval.
2. O
verload may not be repeated until junction
temperature has returned to steady-state
rated value.
Lxx04Ry
Lxx04Ly
Lxx04Dy
Lxx04Vy
10
1
1
10
100
1000
Surge Current Duration – Full Cycles
Note: xx = voltage/10, y = sensitivity
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Soldering Parameters
Pb – Free assembly
Pre Heat
- Temperature Min (Ts(min))
150°C
- Temperature Max (Ts(max))
200°C
- Time (min to max) (ts)
60 – 180 secs
Average ramp up rate (Liquidus Temp) (TL) to peak
5°C/second max
TS(max) to TL - Ramp-up Rate
5°C/second max
Reflow
- Temperature (TL) (Liquidus)
217°C
- Temperature (tL)
60 – 150 seconds
Peak Temperature (TP)
260°C +0/-5
Time within 5°C of actual peak Temperature (tp)
20 – 40 seconds
Ramp-down Rate
5°C/second max
Time 25°C to peak Temperature (TP)
8 minutes Max.
Do not exceed
280°C
Physical Specifications
Terminal Finish
Body Material
Terminal Material
100% Matte Tin-plated
UL Recognized compound meeting
flammability rating V-0
Copper Alloy
tP
TP
Temperature
Reflow Condition
Ramp-up
TL
tL
TS(max)
Preheat
TS(min)
25
Ramp-do
Ramp-down
tS
time to peak temperature
Time
Environmental Specifications
Test
AC Blocking
Temperature Cycling
Design Considerations
Temperature/Humidity
Careful selection of the correct component for the
application’s operating parameters and environment will
go a long way toward extending the operating life of the
Thyristor. Good design practice should limit the maximum
continuous current through the main terminals to 75% of
the component rating. Other ways to ensure long life for
a power discrete semiconductor are proper heat sinking
and selection of voltage ratings for worst case conditions.
Overheating, overvoltage (including dv/dt), and surge
currents are the main killers of semiconductors. Correct
mounting, soldering, and forming of the leads also help
protect against component damage.
High Temp Storage
Low-Temp Storage
Resistance to
Solder Heat
Solderability
Lead Bend
Specifications and Conditions
MIL-STD-750, M-1040, Cond A Applied Peak AC
voltage @ 125°C for 1008 hours
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min dwell time
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85% rel humidity
MIL-STD-750, M-1031,
1008 hours; 150°C
1008 hours; -40°C
MIL-STD-750 Method 2031
ANSI/J-STD-002, category 3, Test A
MIL-STD-750, M-2036 Cond E
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Dimensions — TO-220AB (R-Package) — Non-Isolated Mounting Tab Common with Center Lead
TC Measuring Point
O
A
E
Area (REF.) 0.17 IN2
Dimension
8.13
.320
P
A
MT2
B
C
13.36
.526
D
7.01
.276
Notch In
Gate Lead
To ID.
Non-isolated
Tab
F
R
Inches
Millimeters
Min
Max
Min
Max
0.380
0.420
9.65
10.67
2.92
B
0.105
0.115
2.67
C
0.230
0.250
5.84
6.35
D
0.590
0.620
14.99
15.75
E
0.142
0.147
3.61
3.73
F
0.110
0.130
2.79
3.30
G
0.540
0.575
13.72
14.61
H
0.025
0.035
0.64
0.89
J
0.195
0.205
4.95
5.21
K
0.095
0.105
2.41
2.67
L
0.060
0.075
1.52
1.91
L
M
0.085
0.095
2.16
2.41
H
N
0.018
0.024
0.46
0.61
O
0.178
0.188
4.52
4.78
P
0.045
0.060
1.14
1.52
R
0.038
0.048
0.97
1.22
Min
Max
Min
Max
0.380
0.420
9.65
10.67
2.92
G
K
N
J
MT1
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
M
MT2 GATE
Dimensions — TO-220AB (L-Package) — Isolated Mounting Tab
TC Measuring Point
O
A
E
P
Area (REF.) 0.17 IN2
Dimension
8.13
.320
A
B
C
13.36
.526
D
7.01
.276
F
R
G
L
H
K
N
J
MT1
MT2 GATE
M
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
Inches
Millimeters
B
0.105
0.115
2.67
C
0.230
0.250
5.84
6.35
D
0.590
0.620
14.99
15.75
E
0.142
0.147
3.61
3.73
F
0.110
0.130
2.79
3.30
G
0.540
0.575
13.72
14.61
H
0.025
0.035
0.64
0.89
J
0.195
0.205
4.95
5.21
K
0.095
0.105
2.41
2.67
L
0.060
0.075
1.52
1.91
M
0.085
0.095
2.16
2.41
N
0.018
0.024
0.46
0.61
O
0.178
0.188
4.52
4.78
P
0.045
0.060
1.14
1.52
R
0.038
0.048
0.97
1.22
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Dimensions — TO-251AA (V-Package) — V-PAK Through Hole
TC Measuring Point
E
MT2
Area: 0.040 IN2
H
D
Dim
5.28
.208
J
A
5.34
.210
B
R
P
Q
S
K
C
MT1
L
F
MT2
GATE
G
I
Inches
Millimeters
Min
Typ
Max
Min
Typ
A
0.037
0.040
0.043
0.94
1.01
Max
1.09
B
0.235
0.242
0.245
5.97
6.15
6.22
C
0.350
0.361
0.375
8.89
9.18
9.53
D
0.205
0.208
0.213
5.21
5.29
5.41
E
0.255
0.262
0.265
6.48
6.66
6.73
F
0.027
0.031
0.033
0.69
0.80
0.84
G
0.087
0.090
0.093
2.21
2.28
2.36
H
0.085
0.092
0.095
2.16
2.34
2.41
I
0.176
0.180
0.184
4.47
4.57
4.67
J
0.018
0.020
0.023
0.46
0.51
0.58
K
0.035
0.037
0.039
0.90
0.95
1.00
L
0.018
0.020
0.023
0.46
0.52
0.58
1.32
P
0.042
0.047
0.052
1.06
1.20
Q
0.034
0.039
0.044
0.86
1.00
1.11
R
0.034
0.039
0.044
0.86
1.00
1.11
S
0.074
0.079
0.084
1.86
2.00
2.11
Dimensions — TO-252AA (D-Package) — D-PAK Surface Mount
MT2
E
D
6.71
.264
5.28
.208
TC Measuring Point
Dim
A
6.71
.264
5.34
.210
B
1.60
.063
P
Q
C
1.80
.071
GATE
F
MT1
MT2
Area : 0.040 IN2
3
.118
G
I
O
L
K
M
N
J
H
4.60
.181
Inches
Millimeters
Min
Typ
Max
Min
Typ
A
0.037
0.040
0.043
0.94
1.01
Max
1.09
B
0.235
0.243
0.245
5.97
6.16
6.22
C
0.106
0.108
0.113
2.69
2.74
2.87
D
0.205
0.208
0.213
5.21
5.29
5.41
E
0.255
0.262
0.265
6.48
6.65
6.73
F
0.027
0.031
0.033
0.69
0.80
0.84
G
0.087
0.090
0.093
2.21
2.28
2.36
H
0.085
0.092
0.095
2.16
2.33
2.41
I
0.176
0.179
0.184
4.47
4.55
4.67
J
0.018
0.020
0.023
0.46
0.51
0.58
K
0.035
0.037
0.039
0.90
0.95
1.00
L
0.018
0.020
0.023
0.46
0.51
0.58
M
0.000
0.000
0.004
0.00
0.00
0.10
N
0.021
0.026
0.027
0.53
0.67
0.69
O
0°
0°
5°
0°
0°
5°
P
0.042
0.047
0.052
1.06
1.20
1.32
Q
0.034
0.039
0.044
0.86
1.00
1.11
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
Product Selector
Part Number
Voltage
400V
600V
Gate Sensitivity Quadrants
800V
1000V
I – II – III
Type
IV
Package
Lxx04L3
X
X
-
-
3 mA
3 mA
Sensitive Triac
TO-220L
Lxx04D3
X
X
-
-
3 mA
3 mA
Sensitive Triac
TO-252 D-PAK
Lxx04R3
X
X
-
-
3mA
3mA
Sensitive Triac
TO-220R
Lxx04V3
X
X
-
-
3 mA
3 mA
Sensitive Triac
TO-251 V-PAK
Lxx04L5
X
X
-
-
5 mA
5 mA
Sensitive Triac
TO-220L
Lxx04D5
X
X
-
-
5 mA
5 mA
Sensitive Triac
TO-252 D-PAK
Lxx04R5
X
X
-
-
5mA
5mA
Sensitive Triac
TO-220R
Lxx04V5
X
X
-
-
5 mA
5 mA
Sensitive Triac
TO-251 V-PAK
Lxx04L6
X
X
-
-
5 mA
10 mA
Sensitive Triac
TO-220L
Lxx04D6
X
X
-
-
5 mA
10 mA
Sensitive Triac
TO-252 D-PAK
Lxx04R6
X
X
-
-
5mA
10mA
Sensitive Triac
TO-220R
Lxx04V6
X
X
-
-
5 mA
10 mA
Sensitive Triac
TO-251 V-PAK
Lxx04L8
X
X
-
-
10 mA
20 mA
Sensitive Triac
TO-220L
Lxx04D8
X
X
-
-
10 mA
20 mA
Sensitive Triac
TO-252 D-PAK
Lxx04R8
X
X
-
-
10mA
20mA
Sensitive Triac
TO-220R
Lxx04V8
X
X
-
-
10 mA
20 mA
Sensitive Triac
TO-251 V-PAK
Qxx04L3
X
X
X
-
10 mA
-
Standard Triac
TO-220L
Qxx04D3
X
X
X
-
10 mA
-
Standard Triac
TO-252 D-PAK
Qxx04V3
X
X
X
-
10 mA
-
Standard Triac
TO-251 V-PAK
Qxx04R3
X
X
X
-
10mA
-
Standard Triac
TO-220R
Qxx04L4
X
X
X
X
25 mA
-
Standard Triac
TO-220L
Qxx04D4
X
X
X
X
25 mA
-
Standard Triac
TO-252 D-PAK
Qxx04R4
X
X
X
X
25mA
-
Standard Triac
TO-220R
Qxx04V4
X
X
X
X
25 mA
-
Standard Triac
TO-251 V-PAK
Packing Options
Part Number
Marking
Weight
Packing Mode
Base Quantity
L/Qxx04LyTP
L/Qxx04Ly
2.2 g
Tube
1000 (50 per tube)
L/Qxx04DyRP
L/Qxx04Dy
0.3 g
Embossed Carrier
2500
L/Qxx04DyTP
L/Qxx04Dy
0.3 g
Tube Pack
750 (75 per tube)
L/Qxx04VyTP
L/Qxx04Vy
0.4 g
Tube Pack
750 (75 per tube)
L/Qxx04LyTP
L/Qxx04Ly
2.2g
Tube
1000 (50 per tube)
L/Qxx04RyTP
L/Qxx04Ry
2.2g
Tube
1000 (50 per tube)
Note: xx = Voltage/10; y = Sensitivity
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21
Thyristors
4 Amp Sensitive & Standard Triacs
TO-252 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
* Cover tape
XXXXXX
DC
MT1
MT2
0.315
(8.0)
0.512 (13.0) Arbor
Hole Dia.
0.059
DIA
(1.5)
XX
DC
XX
XXXXXX
*
DC
0.524
(13.3)
XX
0.63
(16.0)
XXXXXX
Gate
XXXXXX
0.157
(4.0)
12.99
(330.0)
Dimensions
are in inches
(and millimeters).
0.64
(16.3)
Direction of Feed
Part Numbering System
Part Marking System
TO-251AA- (V Package)
TO-252AA- (D Package)
Q 60 04 L 4 xx
LEAD FORM DIMENSIONS
xx : Lead Form Option
DEVICE TYPE
L : Sensitive Triac
Q : Standard Triac
SENSITIVITY & TYPE
Sensitive Triac:
3 : 3 mA (QI, II, III, IV)
5 : 5 mA (QI, II, III, IV)
6 : 5 mA (QI, II, III)
10 mA (QIV)
8 : 10 mA (QI, II, III)
20 mA (QIV)
Standard Triac:
3 : 10 mA (QI, II, III)
4 : 25 mA (QI, II, III)
VOLTAGE RATING
40 : 400V
60 : 600V
80 : 800V
K0 : 1000V
CURRENT RATING
04 : 4A
PACKAGE TYPE
L :TO-220 Isolated
R :TO-220 Non-Isolated
V :TO-251 (V-Pak)
D :TO-252 (D-Pak)
L6004V4
YMLDD
®
Date Code Marking
Y:Year Code
M: Month
TO-220
AB -Code
(L and R Package)
L: Location Code
DD: Calendar Code
Q6004R4
YM
®
®
Date Code Marking
Y:Year Code
M: Month Code
XXX: Lot Trace Code
Disclaimer Notice - Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are
not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at http://www.littelfuse.com/disclaimer-electronics.
© 2021 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: TK.08/23/21