Blocks and Holders
Fuse Blocks
General Information
4. Determine if NEC, CSA, UL, or other requirements
are applicable
If fuse blocks will be installed in equipment to be submitted for agency
approval, the requirements should be obtained from the approving
agency in advance of fuse and fuse block selection.
5. Select the type of wire termination
A choice of three types of wire termination is available:
a) Screw* — for use with spade lugs or ring terminals.
b) Screw with Pressure Plate* — for use with solid or stranded wire
without terminal. Recommended where vibration will be a factor.
c) Box Lug — the most durable. For use with all types of solid wire and
Class B and Class C stranded wire. Not for use with welding cable or
other rope-stranded conductors.
* 1/4” Quick Connect terminals rated for up to 20A are
available on the Midget and Class CC fuse blocks.
Fuse Block Selection
The following guidelines should help simplify the selection of proper
fuse blocks:
Screw
with
Pressure
Plate
(P)
1. Determine the system voltage
Since fuses are selected on the basis of system voltage, fuse blocks are
selected to match the voltage rating of the fuse.
Screw
(S)
Box
Lug
(C)
6. Decide on the number of poles in each block
2. Determine the design short-circuit current
Class H fuse blocks will accept Class H or K5 fuses (which have an
interrupting rating of up to 50,000 amperes) and Class R fuses (which
have a 200,000 A.I.R.). To prevent the possibility of inserting a fuse
with the incorrect interrupting rating, the use of Class R fuse blocks is
recommended for use with Class R fuses. Use Class H fuse blocks with
Class H or K5 fuses. These fuse blocks are dimensionally the same, but
the Class R fuse blocks incorporate a rejection feature which allows only
Class R fuses to be inserted.
The number of poles for each set of fuses is determined by the
characteristics of the circuit. The option to gang individual fuse blocks
into long strips will be determined by the available space and by the
type of wire being used.
Blocks and Holders
Available and/or design short-circuit current is an important
consideration when determining the class of fuse and fuse blocks to
use. If available short-circuit current cannot be determined, or if it will
vary with equipment location, select fuses with a 200,000 ampere
interrupting rating (A.I.R.) and mating fuse blocks with a withstand rating
of 200,000 amperes for maximum safety.
7. Determine if fuse clips need to be reinforced
Fuse clips may have a tendency to lose some of their tension over a
period of time. This may be prevented by specifying reinforced fuse
clips. Reinforced clips are standard on certain fuse blocks (see individual
product pages).
Ordering Information
The Littelfuse fuse block part number consists of 6 or 7 components, as
shown below and in the individual fuse block data tables.
3. Determine the type and ampere rating of the fuse to be used
In addition to voltage and interrupting rating as discussed above, the
fuse ampere rating, opening characteristics (fast acting or time-delay)
and size are other important considerations in fuse selection. Once the
fuse type is selected, the mating fuse block can be chosen. Fuse blocks
are available in 30, 60, 100, 200, 400 and 600 amp ratings, and may be
used with a fuse rated at the corresponding amperage rating or below.
For example, a fuse block rated at 30 amperes may be used with a fuse
rated from 0 to 30 amperes.
For all Class R, H, J, T and 15, 20
& 60A Class G Fuse Blocks
© 2005 Littelfuse • POWR-GARD™ Products Catalog
www.littelfuse.com
For all Class CC, Midget and 30A
Class G Fuse Blocks
111
Blocks and Holders
Class J Fuse Blocks
600 Volt
Class J 600V
Amp
Rating
No. of
Poles
Catalog
Number
Connector Type
Maximum
Wire Size
(Add Suffix Shown)
Pressure
Box
Screw
Plate
Lug
1
LJ60030-1 S (R)
P (R)
C (R)
2
LJ60030-2 S (R)
P (R)
C (R)
S & P = #10 CU
30
C = #6 CU
3
LJ60030-3 S (R)
P (R)
C (R)
Adder LJ60030-A S (R)
P (R)
C (R)
1
LJ60060-1
C (R)
2
LJ60060-2
C (R)
60
C = #2 CU-AL
3
LJ60060-3
C (R)
1
LJ60100-1
CR
100
#2/0 CU-AL
3
LJ60100-3
CR
1
LJ60200-1
C
200
250 MCM CU-AL
3
LJ60200-3
C
1
LJ60400-1
CR
400
(2) 350 MCM CU-AL
3
LJ60400-3
CR
1
LJ60600-1
CR
600
(2) 500 MCM CU-AL
3
LJ60600-3
CR
Note: Reinforcing springs standard on all Class J fuse blocks rated 100A and above.
*For optional fuse block covers, refer to POWR-Covers section of this catalog. For
reinforcing clips on blocks rated 30-60 amp, add “R” suffix to connector type.
Specifications
Features/Benefits
Voltage Ratings:
Ampere Ratings:
Approvals:
LJ60030
1.69"
[7.6]
1.69"
[42.8]
3.38"
3.38"
[85.7]
[85.7]
[85.7]
.30"
TYP.
1.04"
[26.4]
[42.8]
3.38"
.57"
1.16"
JTD_ID/JTD (time-delay) and JLS (fast acting) series fuses
[26.4]
1.69"
[42.8]
Recommended Fuses
1.04"
.216[5.5] x .79[20.0] SLOT
MOUNTING HOLE
[14.5]
[29.4]
1 POLE
© 2005 Littelfuse • POWR-GARD™ Products Catalog
Blocks and Holders
• Phenolic blocks have side barriers for isolation.
• Spring reinforced fuse clips are standard on 100A and larger blocks.
Reinforcing springs are optional on 30 and 60 amp blocks.
• Space saving 30A design — Up to 45% smaller than existing
30A fuse blocks. 30A interlocking adder block available to create
any number of poles (consult factory for availability). Integral DIN rail
mount allows this block to be securely fastened to 35 mm “hat” type
DIN rails without the use of tools.
600 Volts
0 – 600 amperes
UL Listed: File No. E14721
CSA Certified: File No. LR73091
.57" TYP.
2.20"
[14.5]
3.25"
[82.5]
[56.0]
2 POLE
.71"
1.95"
[17.9]
[49.5]
3 POLE
www.littelfuse.com
117
Blocks and Holders
Class J Fuse Blocks
600 Volt
LJ60060
1.67"
3.20"
[42.4]
4.07"
.265" x .325" SLOT
[6.7 x 8.3] TYP.
[120]
4.07"
[103]
4.07"
[103]
2.03"
[103]
2.03"
[51.7]
2.03"
[51.7]
.76"
[19]
4.72"
[81.2]
.45"
[12]
[51.7]
.76"
[19]
1.53"
[38.8]
1 POLE
.45"
[12]
1.53"
[38.8]
1.53"
[38.8]
3 POLE
2 POLE
.57"
.76"
[14 ]
[19]
.45"
[12]
2.09"
[53.0]
Blocks and Holders
LJ60100
1 POLE
LJ60200
1.31"
3.00"
[76.2]
[33.39]
3 POLE
.34" THRU [8.6]
.75" C'BORE [19.1]
x .400" DP. [10.2]
6.13"
[156]
.50"
[13]
.62"
2.00"
[50.8]
118
1 POLE
6J200
2.67"
[16]
[67.9]
www.littelfuse.com
3 POLE
© 2005 Littelfuse • POWR-GARD™ Products Catalog
Blocks and Holders
Class J Fuse Blocks
600 Volt
LJ60400
1 POLE
3 POLE
1 POLE
3 POLE
LJ60600
www.littelfuse.com
Blocks and Holders
© 2005 Littelfuse • POWR-GARD™ Products Catalog
119
很抱歉,暂时无法提供与“LJ600603CR”相匹配的价格&库存,您可以联系我们找货
免费人工找货