LVR040S

LVR040S

  • 厂商:

    HAMLIN

  • 封装:

    插件

  • 描述:

  • 数据手册
  • 价格&库存
LVR040S 数据手册
PolySwitch® PTC Devices PRODUCT: LVR040S DOCUMENT: SCD24906 REV LETTER: L REV DATE: JULY 26, 2016 PAGE NO.: 1 OF 3 Overcurrent Protection Device Specification Status: Released Electrical Rating at 20°C Rated Operating Voltage/ Interrupt Current: 240 VAC /5.5 ARMS 240 VDC /5.5 A DC 135 VAC/20.0 ARMS 135 VDC/20.0 A DC Max Interrupt Voltage: 265 VAC/DC 5.5 ARMS Insulating Material : Cured, Flame Retardant Epoxy Polymer Lead Material: 22 AWG Sn Plated Copper Marking: 240 L040 Manufacturer’s Mark and Voltage Part Identification Lot Identification (can be on back) TABLE I. DIMENSIONS: mm: in*: A B MIN MAX MIN MAX -11.5 -19.5 -(0.46 -(0.77) *Rounded off approximation C MIN 4.3 (0.17) D MAX 5.8 (0.23) MIN 7.6 (0.30) E MAX --- MIN --- MAX 3.8 (0.15) TABLE II. PERFORMANCE RATINGS: IHOLD RATED CURRENT CURRENT RATINGS TIME TO TRIP RESISTANCE POST-TRIP RESISTANCE STANDARD TRIP NOMINAL TRIPPED POWER DISSIPATION @ 265 V RMS AMPS AT 20oC HOLD AMPS AT 20oC SECONDS AT 20oC, 2.0A MAX OHMS AT 20oC MIN MAX 0.6 0.97 OHMS AT 20oC MAX WATTS AT 20oC 1.9 2.0 0.40 HOLD 0.40 Recognitions: Reference Documents: Precedence: Effectivity: Warning: TRIP 0.90 24.0 UL, TUV, CSA, CQC. PS300 This specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Refer to Page 2 of this document for application limitations. © 2016 Littelfuse,Inc Specifications are subject to change without notice. Revised July 26, 2016 Littelfuse.com PolySwitch® PTC Devices Overcurrent Protection Device PRODUCT: LVR040S DOCUMENT: SCD24906 REV LETTER: L REV DATE: JULY 26, 2016 PAGE NO.: 2 OF 3 Warning: Application Limitations for the LVR Product Line 1. Users should independently evaluate the suitability of and test each product selected for their own application. 2. This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can be exceeded in a fault condition. Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame. 3. A PTC device is not a fuse - it is a nonlinear thermistor that limits current. Because under a fault condition all PTC devices go into a high resistance state but not open circuit, hazardous voltage may be present at PTC locations. 4. The devices are intended for protection against occasional overcurrent or overtemperature fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated. 5. In most applications, power must be removed and the fault condition cleared in order to reset a PTC device. However, under certain unusual conditions, a PTC device may automatically reset. Accordingly, PTC devices should not be used in an application where an automatic reset could create a safety hazard, such as garbage disposals and blenders. 6. It is the responsibility of the user to determine the need for back up or fail safe protection to prevent damage that may occur in the event of abnormal function or failure of the PTC device. 7. Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of a PTC device. 8. Devices are not recommended for reflow soldering. 9. Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, or mechanical procedures for electronic components. 10. PTC devices are not recommended to be installed in applications where the device is constrained such that its PTC properties are inhibited, for example in rigid potting materials or in rigid housings which lack adequate clearance to accommodate device expansion. 11. Contamination of the PTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices. © 2016 Littelfuse,Inc Specifications are subject to change without notice. Revised July 26, 2016 Littelfuse.com PolySwitch® PTC Devices Overcurrent Protection Device PRODUCT: LVR040S DOCUMENT: SCD24906 REV LETTER: L REV DATE: JULY 26, 2016 PAGE NO.: 3 OF 3 Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, lifesaving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. © 2016 Littelfuse,Inc Specifications are subject to change without notice. Revised July 26, 2016 Littelfuse.com
LVR040S 价格&库存

很抱歉,暂时无法提供与“LVR040S”相匹配的价格&库存,您可以联系我们找货

免费人工找货