Flashers and Tower Lighting Controls
Sequencing Controls
SC3 / SC4 SERIES
Description
The SC3/SC4 Series are solid-state 3 or 4 channel chasers
designed for sequential three circuit flashing of incandescent
lamp loads. Unlike electromechanical chasers, there are no
contacts to arc, wear, and eventually fail.
Operation
Sequential 3 or 4 circuit flashing of incandescent loads with
equal time delays for each load. Upon application of input
voltage, Load 1 is energized. At the end of the time delay, Load 1
de-energizes and Load 2 energizes. At the end of the time delay,
Load 2 de-energizes and Load 3 energizes. This cycle continues
until input voltage is removed. The set time delay (rate) is the
timing for the whole cycle, for all 3 loads (output contacts).
Reset: Removing input voltage resets the unit and cycle.
Features & Benefits
Wiring Diagram
L1
N/L2
FEATURES
BENEFITS
Totally solid state
and encapsulated
No moving parts to arc and wear out over time and
encapsulated to protect against shock, vibration,
and humidity
1A steady solid
state output
Provides 100 million operations in typical conditions.
Accessories
V = Voltage
L1 = Load 1
L2 = Load 2
L3 = Load 3
L4 = Load 4
P1015-13 (AWG 10/12), P1015-64 (AWG 14/16),
P1015-14 (AWG 18/22) Female Quick Connect
These 0.25 in. (6.35 mm) female terminals are
constructed with an insulator barrel to provide
strain relief.
P1015-18 Quick Connect to Screw Adapter
Screw adapter terminal designed for use with
all modules with 0.25 in. (6.35 mm) male quick
connect terminals.
SC4 shown. For SC3, terminal 6 and
load L4 are eliminated.
Ordering Information
MODEL
INPUT VOLTAGE
RATING
CHANNEL
FLASH RATE
SC3120A
120VAC
1A
3 Sequential
Adjustable
30 - 30FPM
SC4120A
120VAC
1A
4 Sequential
Adjustable
30 - 30FPM
If you don’t find the part you need, call us for a custom product 800-843-8848
© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/sc3-sc4
Rev: 1-A-062316
Flashers and Tower Lighting Controls
Sequencing Controls
SC3 / SC4 SERIES
Specifications
Technical Data
Operation
Flasher Function Diagram
FLASHER (CHASING)
Sequential 3 circuit flashing of
incandescent lamp loads. Fixed rate.
V = Voltage
R = Reset
L1, L2, L3, L4 = Lamps
TD = Time Delay
(all are equal)
For sequential 4 circuit and adjustable rates,
please contact the factory.
Rate
Fixed: 30 operations per minute (±10%)
Input
Voltage
120VAC ±15%
AC Line Frequency
50/60 Hz
Output
Type
Solid state
Rating
1A steady state per output
Mechanical
Mounting
Surface mount with two #6 (M3.5 x 0.6) screws
Termination
0.25 in. (6.35 mm) male quick connect terminals
Dimensions H 88.9 mm (3.5”); W 63.5 mm (2.5”);
D 31 mm (1.22”)
Protection
Circuitry
Encapsulated
Dielectric Breakdown
≥ 2000V RMS terminals to mounting surface
Insulation Resistance
≥ 100 MΩ
Environmental
Operating/Storage
Temperature
-20° to 60°C / -40° to 85°C
Humidity
95% relative, non-condensing
Weight
≅ 5.4 oz (153 g)
4
SC4 shown.
For SC3, L4 is eliminated and L1 TD
begins as soon as L3 TD is completed.
Specifications