0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HMUA-FK-A12504

HMUA-FK-A12504

  • 厂商:

    HIROSE

  • 封装:

  • 描述:

    HMUA-FK-A12504 - MU Type Fiber Optic Connectors - Hirose Electric

  • 数据手册
  • 价格&库存
HMUA-FK-A12504 数据手册
MU Type Fiber Optic Connectors HMU Series Back panel side MU Package side SC FC sFeatures 1. JIS, IEC standard compliant and intermateability test certified. Comply with JIS C 5983 (F14 type fiber optic connectors) and IEC 61754-6. MU intermate test by NTT certified connector. 2. Flame resistant Satisfies flammability rating UL94V-0 Harsh Environment 3. Backplane MU Backplane connector has a self-holding mechanism which does not transfer any force on the back panel when both side of connector assemblies are fully connected. Back panel side connectors can be removed or inserted even both sides are mated. 4. Wide Variety of adapter type Attenuators Number of Fiber connections Type Board Mounting Snap-in Panel Mounting & Screw Panel Mounting Single K K Duplex K K 4 way --K 8 way K K 16 way -K 5. Simplified plugs and Receptacles Extremely small size (only 13.75mm Plug length). MU simplified plug is designed for equipments inside connection. Terminators sApplications Optical terminal equipment, optical relay racks, test equipment, telecommunication equipment and other systems requiring Small Form Factor optical connections. Please contact us if you have any requests. Hirose will offer excellent solutions to meet your requirements. 5 sProduct Specifications Ratings Operating temperature range -25°C to +70°C Storage temperature range -25°C to +70°C MU Item Optical Characteristics Insertion Loss Return Loss SM MM(GI) SM MM(GI) Test Method (IEC 61300/JIS C 5961) Wavelength 1310nm (LD) Wavelength 1310nm (LED) Wavelength 1310nm (LD) Specifications 0.5dB max. (AdPC) 0.3dB max. (AdPC) 40dB min. (AdPC) Simplex plug Engagement force: 20 N max. Separation force: 20 N max. Duplex plug Engagement force: 30 N max. Separation force: 30 N max. Copper alloy split sleeve Zirconia split sleeve 1N to 3N 1N to 2.5N Engagement and SC Separation forces Mechanical Characteristics Measured with corresponding connector. Ferrule with drawal force Cable retention (Straight pull) Durability (cycles, mating/unmating) Vibration Shock Extract zirconia gauge 1.249 ±0.0005 mm diameter from split sleeve. 70N tensile loads for one minute. 200 times (Backplane) 500 times (Plug) Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 axis. Acceleration of 981 m/s2, 6 ms duration, sin half-wave waveform, 10 cycles in each of the 3 axis. -10°C to 65°C, humidity: 90% to 96% 10 cycles -25°C to +70°C 100 cycles 960 hours at 85°C 960 hours at -25°C 48 hours in a 5% concentration of salt mist 1) Insertion loss fluctuation after test: 0.2dB max. 2) No visible damage, dislocation of clamp or cable. FC 1) Insertion loss fluctuation after test: 0.2dB max. 2) No visible damage, cracks or part dislocation. Environmental Characteristics Humidity (Temperature/ humidity- cycles) Change of Temprature Dry heat Cold Salt mist Harsh Environment No significant corrosion. sMaterials Part Material Synthetic resin Steel Zirconia Synthetic resin Stainless steel or copper alloy (Nickel plating) Synthetic resin Zirconia Synthetic resin Zirconia or copper alloy Synthetic resin Attenuators Simplex plug housing Spring Ferrule Simplex adapter housing Adapter metal fittings Simplified receptacle housing Simplified plug Backplane connector housing Terminators Split sleeve Dust cap 6 sFunction diagram MU Duplex plug HMUA-2P2-H1 or HMUA-2P2-H2 and HMUA-F3-A1** Terminator HMUA-TM-P2 Simplex plug HMUA-P2-H1 or HMUA-P2-H2 and HMUA-F3-A1** 8-position Backpanel side HMUB-L8HA-1 or HMUB-L8HB-1 SC 8-position package side HMUB-L8PA-1 Dust cap HMUB-DP-1 Back panel Thickness: 2.4mm or 3.2mm FC Gold plate side Package Harsh Environment Duplex backpanel side HMUB-L2HA-1 or HMUB-L2HB-1 Attenuators Sleeve holder HMUB-SH-1 Dust cap HMUB-DJ-1 Duplex package side HMUB-L2PA-1 Simplex J plug HMUAJ-P1-H1 or HMUAJ-P1-H2 and HMUA-F3-A1** Terminator HMUAJ-TM-P1 Terminators 7 sPlug Housings qSimplex Plug Housing for 2mm cable MU 4.35 3.95 6.6 5.6 23.6 48.5 Part Number HMUA-P2-H1(07) HMUA-P2-H2(07) CL No. 710-0047-9-07 710-0001-8-07 Boot color Blue Light purple SC qSimplex Plug Housing for 0.9mm fiber 4.35 3.95 6.6 5.6 23.6 28 Part Number HMUA-P0.9-H1(01) HMUA-P0.9-H2(01) CL No. 710-0158-0-01 710-0159-2-01 Boot color Blue Light purple FC qDuplex Plug Housing for 2mm cable 8.85 8.45 4.5 JAPAN Harsh Environment 6.6 5.6 23.6 48.5 Part Number HMUA-2P2-H1(07) HMUA-2P2-H2(07) CL No. 710-0048-1-07 710-0002-0-07 Boot color Blue Light purple qDuplex Plug Housing for 0.9mm fiber Attenuators 8.85 8.45 4.5 6.6 5.6 JAPAN 23.6 28 Part Number HMUA-2P0.9-H1(01) HMUA-2P0.9-H2(01) CL No. 710-0162-7-01 710-0163-0-01 Boot color Blue Light purple Terminators qSimplex Plug Housing for 1.1mm Cable 4.35 3.95 5.6 6.6 23.7 54 Part Number CL No. Boot color HMUA-P1.1-H2 710-0133-9 Light purple Note: Ferrules, HMUA-F3A2-A12*(10) should be needed for this plug. (see page 9) Certain assemble tools are also needed. Please contact sales representative for the details. 8 sFerrules qFor MU plugs 0.001 ØA+0 (Hole diameter) MU Ø1 (Hole diameter) 4.95 +0.05 0 12 1.5 Ø1.249±0.0005 .1 2.6 2.6 Ø1.8 Ø3 SC Part Number HMUA-F3-A125(10) HMUA-F3-A1255(10) HMUA-F3-A126(10) CL No. 710-0024-3-10 710-0121-0-10 710-0025-6-10 A dimension 0.1255 0.1255 0.1265 Applicable Fiber cable SM,MM qFor HMUA-P1. 1-H* plug ØA +0.001 (Hole diameter) 0 Ø0.6 (Hole diameter) FC Ø1.249±0.0005 Ø1.525 .1 2.6 2.6 4.95 +0.05 0 12 1.5 Ø1.8 Ø3 Harsh Environment Part Number HMUA-F3A2-A125(10) HMUA-F3A2-A1255(10) HMUA-F3A2-A126(10) CL No. 710-0138-2-10 710-0142-0-10 710-0139-5-10 A dimension 0.1255 0.1255 0.1265 Applicable Fiber cable SM,MM Attenuators Terminators 9 sAdapters qSimplex Adapter / Snap-in Panel Mounting MU BPanel Cutout MU-A JAPAN 26 10.4 7.6 +0.2 0 7.3 10 SC Panel thickness:1.6mm 12 1.8 Part Number HMUA-A-3 CL No. 710-0103-8 Split sleeve Zirconia qSimplex Adapter / Screw Panel Mounting FC BPanel Cutout 17.5 12.5 MU-AS JAPAN 10.7 +0.2 0 Ø 2- 2. 4 12.5±0.2 7.6 +0.2 0 2- Ø2.4 +0.2 0 or 2-M2∞0.4 10.4 26 7.3 Harsh Environment 12 Part Number HMUA-AS-3 CL No. 710-0104-0 Split sleeve Zirconia Attenuators qSimplex Adapter / Board Mounting BBoard Mounting Pattern MU-A MU-A 26 10.4 9.5 12.7 ±0.1 4-Ø2.4±0.1 9.5 ±0.1 6.6 Board thickness: 1.6mm Terminators 12.7 Part Number HMUA-AH-3 CL No. 710-0105-3 Split sleeve Zirconia 10 10.7 +0.2 0 qDuplex adapter / Snap-in Panel Mounting 4.5mm Type 2 2 14 4.5 MU-2A JAPAN BPanel Cutout MU 10.1 +0.2 0 1 1 26 9.8 14.3 +0.2 0 4.5 12 Panel thickness:1.6mm SC 12 1.8 Part Number HMUA-2A-4 CL No. 710-0187-8 Split sleeve Zirconia qDuplex Adapter / Snap-in Panel Mounting 6.25mm Type FC 6.2 5 Refer to page 75 for details of the Attenuators. Part Number HMUA-2AK-1 CL No. 710-0196-9 Split sleeve Zirconia Harsh Environment Note:The outer dimension is the same as the above "HMUA-2A-4". qDuplex Adapter / Screw Panel Mounting qDuplex Adapter / Board Mounting Attenuators BPanel Cutout 5 ±0.2 15 ±0.2 10.1+0.2 0 2- Ø2.4 +0.2 0 or 2-M2∞0.4 BBoard Mounting Pattern 12.7 ±0.1 14.3 +0.2 0 12.7 ±0.1 4- Ø2.4 ±0.1 Terminators Board thickness: 1.6mm Part Number HMUA-2AS-4 CL No. 710-0188-0 Split sleeve Zirconia Part Number HMUA-2AH-4 CL No. 710-0189-3 Split sleeve Zirconia 11 q8-Position Adapter / Snap-in Panel Mounting 12 MU 26 1.8 12 MU-8A JAPAN BPanel Cutout 42.3+0.2 0 10.1+0.2 0 1 2 3 4 5 6 7 8 9.8 1 2 3 4 5 6 7 8 SC 5 4.5 42 Panel thickness:1.6mm Part Number HMUA-8A-3 CL No. 710-0174-6 Split sleeve Zirconia q8-Position Adapter / Screw Panel Mounting FC 26 12 MU-8AS JAPAN BPanel Cutout 42.3 +0.2 0 25±0.2 15 ±0.2 10.1+0.2 0 5 4.5 Harsh Environment 9.8 15 20 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 2-Ø 2.4 25 42 2-Ø2.4 +0.2 or 2-M2∞0.4 0 Part Number HMUA-8AS-3 CL No. 710-0175-9 Split sleeve Zirconia Attenuators q8-Position Adapter / Board Mounting MU-8A 12.7 JAPAN 26 BBoard Mounting Pattern 40.6±0.1 9 Terminators 12.7±0.1 Part Number HMUA-8AH-3 1 1 2 2 3 3 4 4 40.6 42 5 5 6 6 5 4.5 Board thickness: 1.6mm 7 7 8 8 4-Ø2.4±0.1 CL No. 710-0176-1 Split sleeve Zirconia 12 sCost effective adapters q8-Position Adapter / Screw Panel Mounting MU 50.5 46.5 40.5 5 4.5 9.8 2-Ø2.3 26 1.8 SC BPanel Cutout 2-Ø2.4+0.2 or 2-M2∞0.4 0 10.1 +0.3 0 2.5 FC 40.6 +0.2 0 46.5±0.1 Panel thickness:1.6mm Part Number HMUA-8A-2 HMUA-8A-B2 CL No. 710-0155-1 710-0119-8 Split sleeve Zirconia Copper alloy Harsh Environment q16-Position Adapter / Screw Panel Mounting 90 86 80 5 4.5 D B 9 F 7 5 3 1 2-Ø2.3 8.6 9.8 6.6 D B 9 F 1.6 7 5 3 1.2 1 Attenuators 1.8 26 2.5 MU-16A BPanel Cutout 2- Ø2.4+0.2 or 2-M2∞0.4 0 10.1+0.3 0 6.7 +0.2 0 0 1.6 -0.3 80.1+0.2 0 86±0.1 Panel thickness:1.6mm 0 1.2 -0.3 Part Number HMUA-16A-2 HMUA-16A-B2 CL No. 710-0143-2 710-0113-1 Split sleeve Zirconia Copper alloy 8.7 +0.2 0 JAPAN Terminators 13 sAngled Adapters qDuplex Angled Adapter with Shutter / Snap-in Panel Mounting MU BPanel Cutout 10.1 +0.2 0 9.8 12 17.8 +0.2 0 (t=2.5mm) 22 20.1 15.4 Panel 17.6 2.5 11 7.6 30.3 (40˚ ) 2. 7 16.4 Part Number HMUA-2A-40-4-S1 CL No. 710-0194-3 Split sleeve Zirconia 11.8 SC Mounting Angle 40° qDuplex Angled Adapter / Snap-in Panel Mounting FC 26 BPanel Cutout 10.1+0.2 0 12 9.8 (40˚ ) 2. 7 2 2 1 1 11.8 4.5 Panel thickness: 2.5mm Harsh Environment Part Number HMUA-2A-40-4 CL No. 710-0177-4 Split sleeve Zirconia Mounting Angle 40° q4-Position Angled Adapter / Snap-in Panel Mounting 12 9.8 35 26 2. 7 BPanel Cutout 10.1 +0.2 0 2 2 4.5 (40˚ 22.5 ) 31.8+0.2 0 26 Panel thickness: 2.5mm 1 1 Attenuators 2 2 1 1 Part Number HMUA-4A-40-4 CL No. 710-0178-7 Split sleeve Zirconia Mounting Angle 40° Terminators BPanel Cutout Panel Cutout dimensions Fiber Position 06(Duplex+4 position) 08(4 position∞2) 10(Duplex+4 position∞2) 12(4 position∞3) 14(Duplex+4 position∞3) 16(4 position∞4) 18(Duplex+4 position∞4) 20(4 position∞5) Panel cutout:Xmm 047.4 061.4 077.1 091.0 106.7 120.7 136.3 150.3 Panel thickness: 2.5mm ∞ +0.2 0 10.1 +0.2 0 14 17.8 +0.2 0 sEnhanced Shielding Adapter qDuplex shielding Adapter / Screw Panel Mounting 2-Ø 2.4 14 2-9.8 MU C5 26 2 10.1+0.2 0 2-Ø2.4+0.2 0 or M2∞0.4 22 18 2-12.7 Recommended Panel Cutout(2:1) 18±0.1 13 +0.2 0 SC Part Number HMUA-2AS-6 CL No. 710-0209-9 Split sleeve Zirconia Housing Hole(Ø2) Split sleeve Metal shell FC BShielding Effectiveness Example Shielding effectiveness comparison(18~26.5GHz) 90.00 Electric-field strength(dBµV/m) 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 Conventional Adapter HMUA-2A-4 Harsh Environment Shielded Adapter HMUA-2AS-6 Attenuators 18.0 18.5 19.0 19.5 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 25.0 25.5 26.0 26.5 Frequency(GHz) Pre Amplifier Antenna Spectrum Analizer Panel Adapters 12pcs Antenna DATA Panel cutout Terminators PC 45 DATA Shielded box 0 Conventional type Shielded type 10.1 +0.2 0 450 18±0.1 10.1 +0.2 0 0 M2∞ .4 Signal generator Source RF connector RF cable Source Fig.1 Measurement system Fig.2 Shielded box 13 +0.2 0 14.3 450 15 sBackpanel side Connector Housings qDuplex Backpanel side Connector Housing MU BPanel Cutout 4-R0.8 max. 18.9 11.89±0.1 8.39+0.2 0 7.71±0.1 (2-R1) 18.59±0.15 12.2±0.1 8.2 ±0.1 JAPAN 17.8 15.24 4.5 2 1 L2HA (2-R1) 9.8 13.2 6.2 12.3 SC Part Number HMUB-L2HA-1 HMUB-L2HB-1 CL No. 710-0017-8 710-0018-0 Panel thickness 2.4mm 3.2mm Note: Screw fastening torque: 0.03Nm q8-Position Backpanel side Connector Housing FC 8 BPanel Cutout 11.89±0.1 8.39 +0.2 0 (4-R1) 8-R0.8 max. 4.5 7 6 5 4 3 37.3 27.94 L8AH 41.5 1 Harsh Environment 9.8 13.2 6.2 12.3 Part Number HMUB-L8HA-1 HMUB-L8HB-1 CL No. 710-0019-3 710-0020-2 Panel thickness 2.4mm 3.2mm Note: Screw fastening torque: 0.03Nm sSleeve Holder 8 Attenuators 3.75 Ø2.59 Ø3.52 Terminators Gold plated section Part Number HMUB-SH-1 CL No. 710-0021-5 Split sleeve Zirconia Note: This Sleeve Holder should be used for duplex and 8-position package side connector housing and J Plug Housing connector plug. Insert the Sleeve Holder using dedicated tool #HMUB-TS-1. The gold plated section of the Sleeve Holder should be inserted into the package side connector housing. 16 4-3.35+0.2 0 2 27.94 ±0.1 37.6 +0.2 0 sPackage side Connector Housings qDuplex Package side Connector Housing 9 BBoard Mounting Pattern 8.61 ±0.05 5.08 ±0.1 MU 13.85 Ø2.1 ±0.1 5.08 23.3 SC 12.7 18.7 12.7 ±0.1 4 pieces attached 4 pieces attached Ø3.2 ±0.1 Part Number HMUB-L2PA-1 CL No. 710-0015-2 JAPAN 10.5 1.8 M2∞0.4 M2∞0.4 Note : Screw fastening torque : 0.15Nm q8-Position Package side Connector Housing 9 L2PA BBoard Mounting Pattern 5.08±0.1 8.61±0.05 FC 36.45 Ø2.1±0.1 5.08 23.3 Harsh Environment 39.37 42.9 4 pieces attached 4 pieces attached 39.37±0.1 Ø3.2 ±0.1 Part Number HMUB-L8PA-1 CL No. JAPAN 10.5 Note : Screw fastening torque : 0.15Nm 1.8 M2∞0.4 M2∞0.4 710-0016-5 L8PA Attenuators sJ Plug Housing qSimplex J Plug Housing for 0.9mm fiber 3.7 3 Terminators 4.75 15 28 Part Number HMUAJ-P0.9-H1(01) HMUAJ-P0.9-H2(01) CL No. 710-0160-1-01 710-0161-4-01 Boot color Blue Light purple 17 Simplified Receptacles & Plug sFeatures MU qSpace saving Installation image (33) FC SC (15) Harsh Environment Simplified plug Split sleeve Terminators Attenuators 18 sSimplified Receptacles qSimplex Simplified Receptacle / Screw Panel Mounting BPanel Cutout MU 18 13.5 9.9 2-Ø2.4 13.5 ±0.2 8.5 +0.2 0 MU SR JAPAN 2- Ø2.4 +0.2 or 2-M2∞0.4 0 4 6.9 +0.2 0 SC Part Number HMUA-SR-11 HMUA-SR-B1 CL No. 710-0094-9 710-0182-4 Split sleeve Zirconia Copper alloy 20.5 2.5 11.8 8.2 6.6 q8-position Simplified Receptacle / Screw Panel Mounting FC BPanel Cutout 5 4.5 7 5 3 2-Ø2.4 8.4 +0.2 0 1 2-Ø2.4+0.2 or 2-M2∞0.4 0 7 5 3 1 8SR JAPAN 9.8 MU 43.9 48.9 38.9 7 8 39.1 +0.2 0 43.9±0.1 Harsh Environment 8.2 Part Number HMUA-8SR-2 I HMUA-8SR-B2 CL No. 710-0172-0 710-0146-0 Split sleeve Zirconia Copper alloy 3 20.5 Attenuators q10-position Simplified Receptacle / Screw Panel Mounting BPanel Cutout 60 56 50 5 4.5 9 7 5 3 2-Ø2.3 10.1+0.3 0 2-Ø2.4+0.2 or M2∞0.4 0 9.8 9 7 5 3 1 1 50.1+0.2 0 56 ±0.1 Terminators t=1.6 11.75 1.8 20.5 8.2 Part Number HMUA-10SR-4 I HMUA-10SR-B4 CL No. 710-0193-0 710-0201-7 Split sleeve Zirconia Copper alloy 2.5 19 q8-position Simplified Receptacle - for extremely high density applications 5 4.5 7 5 3 1 MU 7 5 3 41 42.3 38.9 7 8.2 1 9.8 SC Part Number HMUA-8SR-3 I HMUA-8SR-B3 CL No. 710-0168-3 710-0117-2 Split sleeve Zirconia Copper alloy q16-Position Simplified Receptacle - for extremely high density applications 5 4.5 FC D B F 9 7 5 3 1 2.2 9 20.5 D B F 9 7 5 3 6.5 80.5 81.8 78.4 7 Harsh Environment 1 9.8 8.2 Part Number HMUA-16SR-55 HMUA-16SR-B5 CL No. 710-0173-3 710-0122-2 Split sleeve Zirconia Copper alloy Attenuators BMounting Example Terminators a 20 2.2 9 20.5 sSimplified Plug 0.001 ØA+0 (Hole diameter) qSimplex simplified Plug for 0.9mm fiber Ø1.249±0.0005 MU 3 2 3 5.75+0.05 0 13.75 Part Number HMUA-FK-A125(04) HMUA-FK-A1255(04) HMUA-FK-A126(04) CL No. 710-0099-2-04 710-0107-9-04 710-0100-0-04 A dimension 0.1255 0.1255 0.1265 Ferrule Applicable Fiber cable SC Zirconia SM, MM sSplit Sleeve FC 0 6.8 -0.1 Harsh Environment Part Number HMUA-D(01) HMUA-SLIT-SLEEVE(01) CL No. 710-0147-3-01 710-0130-0-01 Split sleeve Zirconia Copper alloy sExtraction Tool for Simplified Plug Attenuators 5 20 2.15 3.1 3.25 Terminators Part Number HMUA-FK-T3 CL No. 710-0148-6 21 sDust Caps qDust Cap for Backpanel side connector housings MU 4.35 3.95 2.4 6.6 5.6 23.6 SC Part Number HMUB-DP-1 CL No. 710-0135-4 Applicable connector Back panel side housing qDust Cap for Package side connector housings Ø2.55 Ø4.4 6.2 MUDJ 4 21.6 Part Number CL No. 710-0060-7 Applicable connector housing HMUB-L2PA-1 HMUB-L8PA-1 Harsh Environment HMUB-DJ-1 qDust Cap for Adapters 4.35 3.95 Attenuators 2.4 6.6 5.6 23.6 Part Number HMUA-DP-2 CL No. 710-0131-3 Applicable connector Adapter, simplified receptacle Terminators 22 6.2 JAPAN FC Ø6 sTools qInsertion / Extraction Tool for Plug MU Part Number HMUA-TP-1 HMUB-TP-1 CL No. 710-0074-1 710-0075-4 Color of Tip Blue Brown Remarks For Conventional Adapters SC For MU Backplane system qInsertion / Extraction Tool for Plug Cost effective type FC Part Number HMU/HEMD-1P CL No. ----- Harsh Environment qExtraction Tool for J Plug Attenuators Part Number HMUB-TJ-1 CL No. 710-0076-7 qInsertion / Extraction Tool for Sleeve Holder Terminators Part Number HMUB-TS-1 CL No. 710-0077-0 23 qCrimp Tools MU Part Number HT402/HMUA-P2-H2 CL No. 902-6040-4 Applicable plug housing HMUA-P2-H2,H1 HMUA-2P2-H2,H1 SC qStop Ring Insertion Tool FC Part Number HMUA.J/PR-MD CL No. 902-6019-8 Applicable connector MU plug housings except HMUA-P1.1-H2 Terminators Attenuators Harsh Environment 24
HMUA-FK-A12504 价格&库存

很抱歉,暂时无法提供与“HMUA-FK-A12504”相匹配的价格&库存,您可以联系我们找货

免费人工找货