0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LF07-WBJ-12P

LF07-WBJ-12P

  • 厂商:

    HIROSE

  • 封装:

  • 描述:

    LF07-WBJ-12P - Miniature Waterproof Shielded Connectors - Hirose Electric

  • 数据手册
  • 价格&库存
LF07-WBJ-12P 数据手册
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. NEW Miniature Waterproof Shielded Connectors LF Series Mated dimensions 8.9 mm max. (3 pos.) 36.4 Receptacle Plug Short turn bayonet lock Mating: Insert the plug, and then turn the locking collar clockwise, as indicated by the coupling direction marking. ■Features 1. Ease of shielded termination and connector assembly All components are self-aligning and do not require complex assembly tooling. The shield of the cable is connected with the metal housing of the connector using simple shielding clamp, supplied with the connector. Receptacle Locking collar Coupling direction marking Plug Un-mating: Turn the locking collar counter-clockwise than pull off the plug. 2. Water and dust protected IP67 protection rating. Complete protection against dust penetration and against water penetration when mated assembly is submerged at the depth of 1.8 meter for 48 hours. Coupling direction marking 3. Bayonet lock Short turn bayonet lock assures secure vibration resistant mating of the connectors. Shielding Connection - Plug 4. High current rating capacity Number of contacts 3 4 6, 12 and 20 11 Current rating 5A max. 10A max. 2A max. 10A max. 2A max. Built-in shield connection spring Cable shielding connection clamp Cable 5. RoHS compliant All components and materials comply with the requirements of the EU Directive 2002/95/EC. ■Applications Sensors, robots, injection molding machines, NC, factory automation equipment, surveying instruments, measuring instruments, medical equipment, surveillance cameras and base stations. 2008.5 Ø13 1 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products haveMiniature Waterproof Shielded Connectors products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series● been discontinued, or will be discontinued soon. Please check the ■Product Specifications Voltage rating 125V AC, 175V DC (3 pos.) 125V AC, 125V DC (4 pos.) 30V AC, 42V DC (6 pos. , 12pos. , 20pos.) 125V AC, DC (11 pos. A to D) 30V AC, 42V DC (11 pos. 1 to 7) 5A max. (3 pos.) 10A max. (4 pos.) 2A max. (6 pos. , 12pos. , 20pos.) 10A(11 pos. A to D), 2A(11 pos. 1 to 7) –25ç to +85ç (Note 1) –25ç to +85ç (Note 2) Rating Current rating Operating temperature range Storage temperature range Item 11.Contact resistance Specification 15 mø max. (3, 6, 12, 20 pos.) 15 mø max. (4 pos.) 15 mø max. (A to D), 15mø max. (1 to 7)(11 pos.) 1000 Mø min. 1A DC Conditions 12.Insulation resistance 13.Withstanding voltage No flashover or insulation breakdown. 500V DC (3, 4 pos.) 100V DC (6, 12, 20 pos.) 500V DC (A to D), 100V DC (1 to 7)(11pos.) 1250V AC/one minute (3, 4 pos.) 300V AC/one minute (6, 12, 20 pos.) 1250V AC(A to D),300V AC(1 to 7) / one minute(11pos.) Frequency: 10 to 500Hz, single amplitude of 0.75mm, acceleration of 98 m/s2 for 3 hours in 3 axis. Acceleration of 490m/s2, 11ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis. 1000 cycles Temperature: -55ç ➝ Room temperature ➝ +125ç ➝ Room temperature Time: 30 ➝ 10 to 15 ➝ 30 ➝ 10 to 15 (minutes) 5 cycles 96 hours at temperature of 40ç and humidity of 90% to 95%. Complete dust protection. No water penetration when submerged for 48 hours at the depth of 1.8 meter. 14.Vibration No electrical discontinuity for 10μs max. 15.Shock 16.Durability 16.(Mating/un-mating) 17.Temperature cycle No electrical discontinuity for 10μs max. 30 mø max. (3, 6, 12, 20 pos.) 10 mø max. (4 pos.) 10 mø max.(A to D), 30 mø max.(1 to 7)(11pos.) Insulation resistance: 100 Mø min. Insulation resistance: 110 Mø min. (When temperature high) Insulation resistance: 100 Mø min. (Dray state) When mated with corresponding connector. 18.Humidity 19.Water / dust protection Note 1: Includes temperature rise caused by the current flow. Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating temperature range and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation. ■Materials / Finish Components Body / back shell Insulator Contacts Gasket Material Zinc alloy PPS Copper alloy Chloroprene rubber Finish / Color Nickel plated Black Gold plated Black Remarks –––––––––– UL94V-0 –––––––––– –––––––––– ■Ordering Information 1 Series name 2 Shell size : LF 07 10 13 W : Waterproof type B : Bayonet lock P : Plug R : Receptacle J : Jack : 3, 4, 6, 11, 12, 20 P : Male contact S : Female contact LF 07 - W B P - 6 S 1 2 3 4 5 6 7 3 Waterproof 4 Lock Mechanism 5 Connector type 6 Number of contacts 7 Contact type 2 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series●Miniature Waterproof Shielded Connectors ■Plugs B (Cable dia.) ØA (Shown one example) Unit:mm Part number LF07WBP-3S LF07WBP-3P LF07WBP-6S LF07WBP-6P LF10WBP-4S LF10WBP-4P LF10WBP-12S LF10WBP-12P LF13WBP-20S LF13WBP-20P LF13WBP-11S LF13WBP-11P CL No. 136-0003-7 136-0004-0 136-0001-1 136-0002-4 136-0005-2 136-0006-5 136-0007-8 136-0008-0 136-0009-3 136-0010-2 136-0011-5 136-0012-8 Contact Female Male Female Male Female Male Female Male Female Male Female Male Number of contacts 3 ØA B ØC Weight RoHS 12.3 6 4 14.8 12 20 17.9 11 35.3 5 11g 41.8 7.3 17g YES 51.9 8.7 29g ■Receptacles C D ØB ØA F(HEX) E (Shown one example) Unit:mm Part number LF07WBR-3P LF07WBR-3S LF07WBR-6P LF07WBR-6S LF10WBR-4P LF10WBR-4S LF10WBR-12P LF10WBR-12S LF13WBR-20P LF13WBR-20S LF13WBR-11P LF13WBR-11S CL No. 136-1003-2 136-1004-5 136-1001-7 136-1002-0 136-1005-8 136-1006-0 136-1007-3 136-1008-6 136-1009-9 136-1010-8 136-1011-0 136-1012-3 Contact Male Female Male Female Male Female Male Female Male Female Male Female Number of contacts 3 ØA ØB ØC C 15.15 D E F Weight RoHS 10.3 6 4 12.8 12 20 13 15.05 15.25 19.05 7.65 1M9∞0.75 11 4g 6g 7.75 M11∞0.75 13 5g 6g 9g 10g 9g 10g YES 15.3 17.25 15.9 11 18.3 19.05 7.75 M14∞0.75 17 Note: Recommended hex nut tightening torque: 1.5 to 2 N·m (3,4,6, and 12 pos.), 2 to 2.5 N·m (11, 20 pos.) ØC 3 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products haveMiniature Waterproof Shielded Connectors products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series● been discontinued, or will be discontinued soon. Please check the ■Jacks C ØB ØA (Shown one example) Unit:mm Part number LF07WBJ-3P LF07WBJ-3S LF07WBJ-6P LF07WBJ-6S LF10WBJ-4P LF10WBJ-4S LF10WBJ-12P LF10WBJ-12S LF13WBJ-20P LF13WBJ-20S LF13WBJ-11P LF13WBJ-11S CL No. 136-2003-8 136-2004-0 136-2001-2 136-2002-5 136-2005-3 136-2006-6 136-2007-9 136-2008-1 136-2009-4 136-2010-3 136-2011-6 136-2012-9 Contact Male Female Male Female Male Female Male Female Male Female Male Female Number of contacts 3 ØA ØB C ØD Weight RoHS 10.3 6 11.5 36.3 5.0 11g 4 12.8 12 29g 15.9 11 16.9 52.4 8.7 30g 29g 30g 13.8 42.4 7.3 16g YES 20 4 ØD (Cable dia.) The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series●Miniature Waterproof Shielded Connectors ■Applicable tools Unit:mm Description Manual cable clamp crimp Part number LF-TC-01 CL No. 150-0234-6 LF series Applicable cable dia. 5 (Note) 7.3 · 8.7 HR10A-TC-02 150-0041-2 ■Solder termination fixture Note: Applicable cable dia. is only 5mm for LF series. Part number LF07BP-T01 LF07BJ-T01 LF10BP-T01 LF10BJ-T01 LF13BP-T01 LF13BJ-T01 CL No. 150-0232-0 150-0233-3 150-0235-9 150-0236-1 150-0237-4 150-0238-7 Applicable connectors LF07WBP-6S,6P,3S,3P LF07WBJ-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF10WBJ-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P LF13WBJ-20S,20P,11S,11P ■Panel Cutout Alignment guide ■Contact position arrangement and specifications Shell size LF07 LF10 9 1 10 2 A 1 5 2 6 3 7 A 5 .0 +0 0 unit (mm) Shell size LF07 LF10 B +0.05 0 A Ø9.05 Ø11.05 Ø14.05 B 8.1 10.2 13.1 Panel thickness 0.5 to 2 0.7 to 2 0.7 to 2 LF13 LF13 1 Contact configuration 3 2 1 6 5 4 1 2 3 4 3 1 2 8 B C D 4 6 2 7 3 8 4 5 9 10 7 12 11 3 6 54 11 12 13 14 15 16 17 18 19 20 Number of contacts Withstanding voltage Current rating Insulation resistance Contact resistance Solder pot inner diameter 3 1250V AC 5A 1000Mø 15mø 1.15mm 6 300V AC 2A 4 1250V AC 10A 1000Mø 5mø 12 300V AC 2A 1000Mø 15mø 0.8mm 4 AC1250V 4 10A 11 7 AC300V 7 2A 20 AC300V 2A 1000Mø 4mø 0.8mm 1000Mø 4 5mø 4 Ø1.7 7 15mø 7 Ø0.8 0.8mm 1.7mm Note 1: The contact configuration as viewed from the female contact connector mating side. Note 2: The ▼ symbol indicates polarizing key position. Note 3: Withstanding voltages are test voltage values. 5 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products haveMiniature Waterproof Shielded Connectors products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series● been discontinued, or will be discontinued soon. Please check the ■Termination and Assembly Instructions The connectors are delivered with pre-assembed condition and the disassembly as shown No.1. No. Illustration Solder termination fixture Operation 1 Plug disassembly 1 Insert the plug into securely held solder termination fixture as shown. Fixture Part No. Applicable connector LF07BP-T01 LF07WBP-6S,6P,3S,3P LF10BP-T01 LF10WBP-4S,4P,12S,12P LF13BP-T01 LF13WBP-20S,20P,11S,11P 1 Plug Locking collar Insertion direction Body / insulator assembly Backshell 2 2 Loosen the backshell turning it counter clockwise and remove it from the body/ insulator assembly. 1 Solder termination fixture Jack Jack Disassembly 1 Insert the jack into the securely held solder termination fixture as shown. Fixture Part No. Applicable connector LF07BJ-T01 LF07WBJ-6S,6P,3S,3P LF10BJ-T01 LF10WBJ-4S,4P,12S,12P LF13BJ-T01 LF13WBJ-20S,20P,11S,11P Insertion direction 2 Body / insulator assembly Backshell 2 Loosen the backshell turning it counterclockwise. 2 1 Backshell Connector Assembly 1 Apply a coating of Loctite 7649 (Manufactured by Henckel Japan, Ltd,) primer to the threaded sections of the backshell and the tightening collar. Completely dry the coated surfaces. Threaded section Threaded section Note (1) Drying time at room temperature is approximately 30 to 70 seconds. (2) Ensure sufficient ventilation of the area at time of drying. (3) Take necessary steps to protect the coated surfaces from contamination. Tightening collar 6 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series●Miniature Waterproof Shielded Connectors No. Illustration Operation 2 2 Backshell 2 Strain relief collar Tightening collar Thread the tightening collar, strain relief collar, seal bushing and the backshell over the cable as illustrated. Cable preparation end Seal bushing Cable 3 1 A Cable outer jacket Cable preparation 1 Strip the cable’s outer jacket to the dimensions illustrated in the table 1. Shielding mesh Table 1. Stripping Dimensions Number of Conductors 3 6 4 12 11 20 A mm 8 to 9 13 to 14 14 to 15 22 to 23 (No.A to D) 23 to 24 (No.1 to 7) 23 to 24 Note (1) Exercise caution not to damage the shielding mesh. (2) Any damage to the cable’s outer jacket may affect the waterproof performance of the assembled connector. 2 Shielding mesh Wires Cable outer jacket 2 Fold back the shielding mesh over the cable’s outer jacket assuring that it is uniform on its diameter. 4 to 5mm Wires Cable outer jacket Shielding mesh (Folded back) 3 B Stripping dimensions Cable outer jacket Wires 3 Strip the wires to the dimensions illustrated in the Table 2. Note When stripping the wires exercise caution not to damage it’s insulation, folded over shielding mesh or cable’s outer jacket. Conductors Table 2. Stripping Dimensions Number of Conductors 3 6 4 12 11 20 B mm 2.5±0.5 2±0.5 3±0.5 2±0.5 3±0.5 (No.A to D) 2±0.5 (No.1 to 7) 2±0.5 7 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products haveMiniature Waterproof Shielded Connectors products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series● been discontinued, or will be discontinued soon. Please check the No. Illustration Operation 4 Soldering 1 Soldering conditions Soldering iron tip temperature: 350±10ç Soldering time: within 5 sec. Note (1) Assure that the solder compound is sufficiently melted on the soldering iron tip. (2) When applying, make sure that the solder will flow correctly at all the contact surfaces between the conductor and the contact. 2 –1 Cmm Wire 2 – 1 6, 12, 20, 11(No.1∼7) Conductors Insulator Contact Table 3 Number of Conductors 6 Number of contacts 1 to 6 1 to 9 10 to 12 1 to 5,16 to 20 6 to 15 1 to 4 5 to 7 C mm 4 4 6 4 6 6 4 (1) Place a heat-shrink tubing (inside diameter of 1.1 mm min.) over every other wire. Perform the soldering of the contact and the (2) conductor, with the wire’s insulation touching the contact as shown. After soldering, slide the heat shrink tubing (3) over the soldered joint and shrink it. The tubing should touch the insulator as shown. Heat-shrink tubing 12 20 11 2 –2 Insulator Insulator wall 2 – 2 3, 4, 11(No.A∼D) Conductors Insulator Contact Contact Insulator wall Wire insulation (1) Perform the soldering of the contact and the conductor, with the wire’s insulation touching the contact as illustrated. (2) When soldering, to maintain the insulation between adjacent contacts. Make sure that the wire’s insulation remains below the edge of the insulator’s wall 0.5 mm min., as illustrated. Wire insulation Solder 0.5 mm min. D Cable outer jacket 3 3 After the soldering, keep a distance of D between the contact end and the cable’s outer jacket as illustrated. Note Shielding mesh (Folded back) Table 4. Wire Dimensions Number of Conductors 3 6 4 12 11 20 D mm 6 to 7 10 to 11 13 to 14 18 to 19 The distance of D is required in order to assure correct assembly of the backshell. 8 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series●Miniature Waterproof Shielded Connectors No. Illustration Operation 5 1 Crimping of the Shielding Clamp Solder termination fixture Body / insulator assembly 1 After completion of the soldering operations carefully remove (holding on the locking collar) the body/insulator assembly from the solder termination fixture. Note Soldered joints Exercise caution not to damage or deform the solder joints. 2 Wires Cable outer jacket Cable outer jacket 2 mm max. Copper tape 2 Wrap the folded over shielding mesh with 5 to 6 mm wide copper tape to assure that it will not become loose. Apply the copper tape so that the shielding mesh does not protrude from under it. Shielding mesh Note Copper tape 5 to 6mm After wrapping the copper tape, the tape should overlap itself by 2 mm max. 3 Cable outer jacket Ground clamp Copper tape 1±0.5mm Copper tape Cable outer jacket 3 Insert the “U” shaped shielding clamp over the copper tape as shown on the illustration. It is critical that the overlap of the copper tape is located inside the shielding clamp as shown on the illustration. Note When the end of the copper tape wrapping is positioned at the open side of the ground fitting, the end portion of the copper tape wrapping will no longer be covered by the ground fitting when the ground fitting is crimped. Wires Shielding mesh Overlap of the copper tape Shielding clamp 4 Commercially available pliers E 4 Using commercially available pliers bend the open ends of the shielding clamp as illustrated, assuring that it stays in place. The dimension of E. between opposing edges of the shielding clamp is necessary to assure correct final crimp. Table 5 Shell size Shielding clamp Overlap of the copper tape LF07 LF10 LF13 E 5mm max. 7mm max. 9 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products haveMiniature Waterproof Shielded Connectors products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series● been discontinued, or will be discontinued soon. Please check the No. Illustration Operation Crimping tool 5 5 Forming cavity 5 Both sides of the shielding clamp must be placed in the forming cavity of the tool (as shown on the illustration) and crimped over the cable by closing the tool completely. Crimping tool Forming cavity HR10A-TC-02 5.3 7.0 7.9 9.1 Applicable cable diameter Shielding clamp diameter after crimping 5mm ––– 7.3mm 8.7mm 5.3mm to 5.5mm 5.3 7.0 ––– 7.9mm to 8.1mm 9.1mm to 9.3mm LF-TC-01 6 1 , 2 Threaded section Backshell Connector Assembly 1 Place the body/insulator assembly in the applicable solder termination fixture. For plug assembly Fixture Part No. LF07BP-T01 LF10BP-T01 LF13BP-T01 For jack assembly Fixture Part No. LF07BJ-T01 LF10BJ-T01 LF13BJ-T01 Applicable connector LF07WBJ-6S,6P,3S,3P LF10WBJ-4S,4P,12S,12P LF13WBJ-20S,20P,11S,11P Applicable connector LF07WBP-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P Wrench width : D Table 6 Shell size Tightening torque Wrench width LF07 LF10 LF13 1N·m~1.5N·m 1N·m~1.5N·m 1.5N·m~2N·m 10mm 13mm 16mm 2 Coat the thread section of the body/insulator assembly with Loctite 271 compound (manufactured by Henckel Japan, Ltd.) or equivalent, tightening it with a torque specified in the table 6. It is critical that the cable itself will not turn or twist during this operation. Note 3 , 4 3 Seal bushing Strain relief collar Slide forward the seal bushing and insert it in the backshell until fully seated. Slide forward the strain relief collar and insert it in the backshell, making sure that the opposing protrusions fit inside the corresponding grooves, as shown on the illustration. 4 Groove Protrusion Tightening collar Note It is critical that the protrusions are inside the corresponding grooves. 5 Threaded section Tightening collar 5 Verify that the Locktite 7649 primer (or equivalent) on the threaded sections of the backshell and tightening collar are dry. Apply the Locktite 271 compound to the tightening collar’s threaded section and attach it to the backshell. 10 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF Series●Miniature Waterproof Shielded Connectors No. Illustration Operation Tightening collar 6 6 6 Remove the connector from the solder termination fixture, holding it by the locking collar. Do not pull on the cable. Wrench width Shell size Tightening torque Wrench width LF07 LF10 LF13 0.8N·m~1N·m 0.7N·m~1N·m 1 N·m~1.5 N·m 10mm 13mm 16mm 1. To maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applicable diameter. 2. Consult HRS representative when using different cables. ■Cable Specifications (Reference) No. of contact Material Conductor Size (mm) Construction Size (AWG) Sectional area Diameter (mm) Insulator Diameter (mm) Material Density Diameter (mm) Diameter (mm) Ø0.18 AWG #20 ––––––– Ø0.98 Ø1.5 (Standard) Soft copper wire 85% Ø3.6 Ø5±0.2 3 pos. Soft copper wire Ø0.26 AWG #16 1.25 Ø1.5 Ø2.1 (Standard) 0.3 Soft copper wire 80% Ø5.5 Ø7.3±0.2 4 pos. Soft copper wire Ø0.16 AWG #26 ––––––– Ø0.48 0.2 Soft copper wire 85% Ø3.4 Ø5±0.2 6 pos. Soft copper wire 12 pos. Soft copper wire Ø0.16 7 /Ø0.16 mm dia. AWG #26 0.14 Ø0.48 0.21 Soft copper wire 80% Ø4.2 Ø7.3±0.2 20 pos. Soft copper wire Ø0.16 7 /Ø0.16 mm dia. AWG #26 0.14 Ø0.48 Ø0.9 (Standard) 0.21 Soft copper wire 80% Ø5.1 Ø8.7±0.2 Ø0.26 11 pos. Soft copper wire Soft copper wire Ø0.16 26 /Ø0.26 mm dia. 7 /Ø0.16 mm dia. AWG #16 AWG #26 1.25 Ø1.5 0.3 0.14 Ø0.48 0.235 80% Ø6.7 Ø8.7±0.2 20 /Ø0.18 mm dia. 20 /Ø0.26 mm dia. 7 /Ø0.16 mm dia. Ø0.88 (Standard) Ø0.9 (Standard) Ø2.1 (Standard) Ø0.95 (Standard) Soft copper wire Thickness (mm) 0.26 Jacket Shield 11
LF07-WBJ-12P 价格&库存

很抱歉,暂时无法提供与“LF07-WBJ-12P”相匹配的价格&库存,您可以联系我们找货

免费人工找货