NEW
Power Supply Connectors For Industrial Equipment
PX Series
Structure prevents mis-insertion
Key
Shape of opening prevents reverse insertion
Pict.-➀
sFeatures
1. Power supply connector for high-current:
Withstands voltage of 2200V AC max. and 10A/contact (60A/6contacts) of rated current.
Reliable terminal structure
retainer
2. Housing design prevents incorrect insertion:
Opening section is designed to prevent reverse insertion and mating direction is easily checked. Additionally, the opening section is keyed to prevent misalignment of plugs in parallel applications. (See the right Pict.➀.)
Sealing section (3 contacts)
As this window is opened, contact section can easily be checked. Wall structure prevents retainer deformation 16-18
Contact spring guard section
Applicable Wire Size (AWG No.) Since the retainer portion is lowered by onestep, the possibility of spring deformation is minimized even if the lock is released.
3. Reduced Size:
When compared to traditional products, Hirose’s plug is smaller in size by 65% and the receptacle is smaller by 55%. (For more details, refer to page 2.)
Fig.-➀
4. Reliable contact structure: ➀Three point contact ➁Gold plated contacts (standard) with high-level environmental
resistance ➂Contact spring guard structure ➃Structure prevents retainer deformation (Refer to the right Fig.➀.)
Label space
5. Easy Cable Assembly: ➀Use of dedicated crimping tools will make harness work
easier.One tool crimps both AWG#16 and AWG#18 wire. ➁Positive lock can be felt on contact insertion. ➂Release of contact lock can easily be performed with dedicated jig, which facilitates the wiring modification after assembly.
Avoid any short between adjacent terminals
Two layer structure enables high-density mounting.
99.4
1
sProduct Specifications
Temp. Range Ratings Voltage Current Description 1.contact resistance 2.insulation resistance 3.voltage resistance 4.Insertion/Withdrawal life 5.vibration resistance 6.shock resistance -55ç~+105ç AC600V 10A Specifications 10mø maximum 1000Mø minimum No flashover/dielectric breakdown Measured at 100mA. Measured at DC 500V. AC 2200V for 1 minute. 1000 times of insertion/withdrawal Frequency:10-55Hz(1cycle,5 min.) One-sided amplitude:Test at 0.75mm, 3 directions for 2 hours, respectively Acceleration: 490m/S2 Duration: 11ms Test at sine half-wave, 3 axes, bi-directional three times, respectively. Test the followings for 5 cycles : Temperature : -55/+05~+35/+85/+05~+35ç Time : -30/+10~+15/+30/+10~15Minutes Continuous condition of 40±2ç in temperature and 90~95% in humidity for 96 hours. Leave in 5% of salt water for 48 hours. Requirements
➀Contact resistance : 20mø or less ➁No damage, cracks or looseness of parts ➀No instantaneous electric disconnection of
10 µs or more ➁Contact resistance : 20møor less ➂No damage, cracks or looseness of parts
7.temperature cycle
➀Contact resistance : 20mø or less ➁Insulation resistance : 1000Mø or more ➂No damage, cracks or looseness of parts ➀Contact resistance : 20mø or less ➁Insulation resistance : 1000Mø or more ➂No damage, cracks or looseness of parts ➀No heavy corrosion
8.humidity resistance in steady state 9.Corrosion, salt mist
sMaterial Quality/Processing
Parts Contacts Insulator Metal fixture Material Copper alloy PBT resin(UL94V-0) Copper alloy Solder plating Finish Gold plating
BComparison In Size With Conventional Equivalent
(mm)
PX Width Plug Height Depth Width Receptacle Height Depth 34.2 07.0 23.0 28.0 14.8 27.4
A company-made 07.15 22.80 39.40 18.47 27.18
A
Plug
A
Receptacle
12
12 A 6
width width
7 F A
depth
F
R
F S
For volume ratio, plug is downsized to : nearly 65%; and receptacle : nearly 55%.
1
2
height
height
depth
6
11 5
10 4
9 3
PX10 AF6WP
2
8
7 1
1
2
3
4
5
6
44.94
PX50-AF6S
sReceptacles
q6position/2row
Type
PX10-AF6WP CL236-0001-0
BDimensions For Circuit Board
BTerminal-To-Terminal Distance
Installation(For Your Information) t=1.6~2.4
Of Board Installed Section
✽ Where t=1.6 (Setting value depends on thickness of boards.)
3
q4Position/2
Row Type
PX10-AD4WP CL236-0005-0
Label space size 17.2∞10.2
25.2 terminal No.5 21.2 terminal No.8
5
D
A
8
R
D A
7.3
S
1 4
14.8
27.4
terminal No.1 3.4 10.2 22.8
terminal No.4
4.1
3.8 8.4 8 6.7 11.4
BDimensions For Circuit Board
BTerminal-To-Terminal Distance
t=1.6~2.4
Installation(For Your Information)
10.2 terminal No.6 terminal No.5 terminal No.2 terminal No.1
.75 R0
1.4 8-Ø -hole) ugh 1.5 thro
Of Board Installed Section
5. 09
P=3.4 terminal No.8 terminal No.7 terminal No.3 P= 3.8 terminal No.4
(6)
(8)
(
3.7 π
6.7
11.4
board end
(through-hole) 22.8
connector position
✽ Where t=1.6 (Setting value depends on thickness of boards.)
4
4.5
8 4
7 3
PX10 AD4WP
6 2
5 1
5. 09
sPlug
q6-Position
Type
PX50-AF6S CL236-0002-2
q4-Position
Type
terminal No.2 terminal No.1 terminal No.3 terminal No.4
(This picture shows the state of cable insertion.)
A
1
2
3
4
PX50-AD4S CL236-0006-3
21.2 27.4 Label space size 11.6∞6.1
PX50 --- AD4S
21.5
23
A
D
7
5
sSimple-Type Plug Holder Cover
qFor
6-Position Type
PX-6WS-CV
qFor
CL236-0004-8
4-Position Type
22.8
15.9
A
PX4WS-CV
PX-4WS-CV
CL236-0007-6
Label Space Size 17.2∞6.1
BInstallation status
➀ ➁
BInstallation method diagram
q6-Position
Type
➂
➃
q4-Position
Type
A D
10.6
PX50-AD4S (2-layerd)
1
2
3
The holder cover is not a rugged support fixture but only meant for alignment of the plugs. If external force is imposed by pulling of cables, etc. before mating, please bundle all cables together around the connector with union bands, etc.
6
A
D
A
4
PX4WS-CV
sTerminal
AWG No. # 16, 18 Delivery state Reeled Packed Product No. PX50-SC-231 PX50-SC-131 CL No. CL236-0003-5 CL236-0008-9 Packing volume 1 reel: 5000 cables 1 pack: 100 cables
Please order by integral multiple of the packing volume.
sCrimping Tool
Description Automatic Manual Form Auto crimper Applicator Hand tool (✽) Product No. CM-105 AP105-PX50-3 HT104/PX50-3 PX50-SC-TC CL No. CL901-0005-4 CL901-2573-8 CL250-0229-4 CL250-0233-1 Adaptive terminal PX50-SC-231 PX50-SC-131 PX50-SC-✽31
Crimp terminal drawing jig
✽ For our manual crimping tools, we employ the rotate-replace procedure to use the crimper depending on wire size.
Note.) Since manual crimping tool cannot provide fine adjustment of crimp height, please use the proper crimp height of auto crimper in crimping of the wires other than specified ones
7
sCrimp Terminal Drawing Jig
PX50-SC-TC
CL250-0233-1
When the crimp terminal drawing jig is inserted and pushed from the fitting section of a connector as shown below, retainer lock of the terminal will be released. Then please extract the cable. If the retainer is too lowered after extracting terminal, put it in a former position and reinsert. Position and direction of the jig top to be inserted are as shown in the Figures below. Be careful that any mistake will lead to the damage of terminal.
qHow
To Extract Crimp Terminal ➀ ➁
➂
➃
✽ Insert the jig top into the peak of convex section on terminal hole.
Creativ e
ks to World El e Lin
HIROSE ELECTRIC CO.,LTD.
5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8586,JAPAN PHONE:3-3491-9741 FAX :3-3493-2933
8
The contents of this catalog are current as of April 1999. Contents are subject to change without notice for the purpose of improvements.
onics ctr
很抱歉,暂时无法提供与“PX10-AF6WP”相匹配的价格&库存,您可以联系我们找货
免费人工找货