060-G626-05

060-G626-05

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    060-G626-05

  • 数据手册
  • 价格&库存
060-G626-05 数据手册
MODEL FP2000 008835 Issue 6 Differential Pressure Transducer DESCRIPTION The FP2000 series is a configurable differential pressure transducer which allows the customer to select the configuration which best fits the needs of the application. Choose from multiple accuracies, outputs, pressure ports, electrical terminations, and pressure ranges. The FP2000 is available with differential wet/wet and wet/dry configurations. DIFFERENTIATION • Welded stainless steel construction • Customized specifications available • Configurable platform enables a sensor to be built to customer requirements • Bi-directional functionality of pressure measurement • Optional bi-directional calibration available • Small package size VALUE TO CUSTOMERS • Built on the Honeywell history of higher-quality pressure sensing technologies • Configurable platform creates a wide range of standard configurations • Broad compensated temperature ranges • Multiple outputs to choose from to meet variety of application needs POTENTIAL APPLICATIONS • Test stands (automotive, aerospace, and industrial) • R&D test labs • Hydraulic and pneumatic system monitoring • Leak detection • Pump and compressor control • Tank level measurement • Monitor pressure changes for preventive maintenance • Flow rate measurement Approved Approved FEATURES • mV/V, 4 mA to 20 mA, ±5 Vdc, ±10 Vdc • Differential (wet/wet, wet/dry) • Multiple electrical connector and pressure port offerings • Intrinsically safe option • CE available FP2000 pressure sensors are custom built from stocked components. Please see http://sensing.honeywell.com for updated listings FIGURE 1. TYPICAL SYSTEM DIAGRAM In-line amplifiers (Used with unamplified units only) Amplifier Output Universal in-line amplifiers U2W 4 mA to 20 mA (2-wire) 6q PORTFOLIO 6r 6a Customer supplied Chart recorder Alarm panel Data acquisition Computer PLC Model FP2000 6m Mating connectors & cables PT06A-10-6S (option 6a) mV/V – 4 conductor cable 4 mA to 20 mA – 3 conductor cable 0-5/ 0-10 Vdc – 3 conductor cable Standard DIN 43650 (option 6m) Mini DIN 40050 (option 6n) Display units SC500 SC2000 SC2001 SC3004 GM (unamp. only) GM-A (amp. only) NK (unamp. only) HH (unamp. only) From general process pressure transducers to hazardous location pressure products, Honeywell offers a comprehensive selection of gage, absolute, differential, vacuum, and barometric pressure transducers to meet market demands. Each of our trandsucers can be customized to meet your needs, whatever your application. To view the entire product portfolio, click here. DIFFERENTIAL PRESSURE TRANSDUCER, MODEL FP2000 TABLE 1. PERFORMANCE SPECIFICATIONS TABLE 3. MECHANICAL SPECIFICATIONS CHARACTERISTIC MEASURE CHARACTERISTIC MEASURE Accuracy see Note 1 Media Gas, liquid Output (selectable) mV/V , 4 mA to 20 mA (two wire), ±5 Vdc, ±10 Vdc Resolution Infinite Overload safe Positive (+) direction Model FDW and FDD 4X full scale or 3000 psi whichever is less Overload safe Negative (-) direction Model FDW and FDD 4X full scale or 250 psi whichever is less Overload burst Positive (+) direction Model FDW and FDD 3000 psi Overload burst Negative (-) direction Model FDW and FDD 500 psi Wetted material Ha C276 & 316L Stainless Steel TABLE 2. ELECTRICAL SPECIFICATIONS CHARACTERISTIC MEASURE Amplified (4 mA to 20 mA; ±5 Vdc) 9 Vdc to 28 Vdc Amplified (±10 Vdc) 15 Vdc to 28 Vdc Unamplified (mV/V) 10 Vdc Note 1: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. Consult Factory to specify 4 mA at negative full scale and 20 mA at positive full scale. Note 2: All amps add 2 inches to sensor housing length. TABLE 4. ENVIRONMENTAL SPECIFICATIONS ORDER CODE FDD FDW Temperature, error band RANGE TEMPERATURE, COMPENSATED less than 1 psi 10 °C to 45 °C [50 °F to 110 °F] 1 psi and less than 5 psi 5 °C to 50 °C [40 °F to 120 °F] 5 psi and above 5 °C to 60 °C [40 °F to 140 °F] less than 1 psi 10 °C to 45 °C [50 °F to 110 °F] 1 psi and less than 5 psi 5 °C to 50 °C [40 °F to 120 °F] TEMPERATURE, OPERATING TEMPERATURE, OPERATING -40 °C to 116 °C [-40 °F to 240 °F] -29 °C to 85 °C [-20 °F to 185 °F] Unamplified Output: Option 2U Voltage Output: Option 2D,2E,2F,2G Current Output: Option 2P,2Y,2N 5 psi and above 5 °C to 60 °C [40 °F to 140 °F] 0.10 % accuracy ±0.5 % full scale – – 0.25 % accuracy ±1.0 % full scale – – 2 sensing.honeywell.com DIFFERENTIAL PRESSURE TRANSDUCER, MODEL FP2000 TABLE 5. INTERNAL AMPLIFIERS AMPLIFIER SPECIFICATIONS UNAMPLIFIED OUTPUT: OPTION 2U VOLTAGE OUTPUT: OPTION 2D VOLTAGE OUTPUT: OPTION 2G CURRENT TWO-WIRE: OPTION 2P Output signal at null 0 Vdc 0 Vdc 0 Vdc 4 mA Output signal at full scale output 50 mV 5 Vdc 10 Vdc 20 mA Input power (voltage) 10 Vdc 9 Vdc to 28 Vdc 15 Vdc to 28 Vdc 9 Vdc to 32 Vdc Input power (current) 2 mA @ 10 Vdc 10 mA 15 mA 4 mA to 24 mA Frequency response Natural frequency 300 Hz 300 Hz 300 Hz Power supply rejection N/A 60 dB 60 dB 60 dB Operating temperature -40 °C to 116 °C [-40 °F to 240 °F] -29 °C to 85 °C [-20 °F to 185 °F] -29 °C to 85 °C [-20 °F to 185 °F] -29 °C to 85 °C [-20 °F to 185 °F] Reverse voltage protection N/A Yes Yes Yes Short circuit protection N/A Momentary Momentary Yes AMPLIFIER SPECIFICATIONS VOLTAGE OUTPUT: OPTION 2E VOLTAGE OUTPUT: OPTION 2F INTRINSICALLY SAFE AMP: OPTION 2N (2N)*** CURRENT TWO-WIRE: OPTION 2Y Output signal at null 0 Vdc 0 Vdc 4 mA 4 mA Output signal at full scale output 5 Vdc 10 Vdc 20 mA 20 mA Input power (voltage) 9 Vdc to 28 Vdc 15 Vdc to 28 Vdc 9 Vdc to 28 Vdc 9 Vdc to 32 Vdc Input power (current) 10 mA 15 mA 4 mA to 24 mA 4 mA to 24 mA Frequency response 2000 Hz 2000 Hz 2000 Hz 2000 Hz Power supply rejection 60 dB 60 dB 60 dB 60 dB Operating temperature -29 °C to 85 °C [-20 °F to 185 °F] -29 °C to 85 °C [-20 °F to 185 °F] -29 °C to 85 °C [-20 °F to 185 °F] -29 °C to 85 °C [-20 °F to 185 °F] Reverse voltage protection Yes Yes Yes Yes Short circuit protection Momentary Momentary Yes Yes Sensing and Internet of Things 3 DIFFERENTIAL PRESSURE TRANSDUCER, MODEL FP2000 FIGURE 2. MOUNTING DIMENSIONS ELECTRICAL TERMINATION Code 6a: 6-pin, vented, Bendix style Code 6m: 4-pin, vented, standard DIN (43650) Code 6q: 4-conductor, vented, integral cable, 1,52 m [5 ft] FDW Code 6r: 4-conductor, vented, integral cable, conduit fitting 1,52 m [5 ft] FDD PRESSURE PORTS Code 5a 1/4-18 NPT female Code 5b 1/4-18 NPT male Code 5c 7/16-20 UNF female Code 5d 7/16-20 UNF male Code 5f G 1/4 B female Code 5g G 1/4 B male Code 5h 1/8-27 NPT female Code 5i 1/8-27 NPT male Code 5p M12-1.5 male Code 5q M12-1.5 female Code 5r 9/16-18 SAE male Code 5s 9/16-18 SAE female Up to 1000 psi Up to 1000 psi 4 sensing.honeywell.com DIFFERENTIAL PRESSURE TRANSDUCER, MODEL FP2000 TABLE 7. WIRING CODES UNAMPLIFIED OUTPUT: OPTION 2U VOLTAGE OUTPUT: OPTION 2D/2E VOLTAGE OUTPUT: OPTION 2G/2F CURRENT TWO-WIRE: OPTION 2P/2Y INTRINSICALLY SAFE AMP: OPTION 2N (2N)*** BENDIX PTIH-10-6P (OPTION 6A) No shunt cal A B C D E F (+) Excitation (+) Excitation (-) Excitation (-) Excitation (-) Output (+) Output A B C D E F (+) Supply (-) Supply return (-) Output 0 Vdc to 5 Vdc (+) Output No connection No connection A B C D E F (+) Supply (-) Supply return (-) Output 0 Vdc to 10 Vdc (+) Output Vdc No connection No connection A B C D E F (+) Supply No connection No connection (+) Output 4 mA to 20 mA No connection No connection A B C D E F (+) Supply No connection No connection (+) Output 4 mA to 20 mA Case ground No connection With shunt cal (option 3d) A B C D E F (+) Excitation (-) Excitation (+) Output (-) Output No connection Shunt Cal A B C D E F (+) Supply (-) Supply return (-) Output 0 Vdc to 5 Vdc (+) Output No connection Shunt cal A B C D E F (+) Supply (-) Supply return (-) Output 0 Vdc to 10 Vdc (+) Output No connection Shunt cal A B C D E F (+) Supply No connection No connection (+) Output 4 mA to 20 mA No connection Shunt cal A B C D E F (+) Supply No connection No connection (+) Output 4 mA to 20 mA No connection Shunt cal 1 2 3 GND (+) Supply (+) Output Supply/ output com. No connect. to case 1 2 3 GND (+) Supply (+) Output Supply/ output com. No connect. to case 1 2 3 GND (+) Supply (+) Output 4 mA to 20 mA No connection No connection 1 2 3 GND (+) Supply (+) Output Case ground No connection 1 2 3 GND (+) Supply (+) Output Supply/output com. Shunt cal 1 2 3 GND (+) Supply (+) Output Supply/output com. Shunt cal 1 2 3 GND (+) Supply (+) Output 4 mA to 20 mA No connection Shunt cal 1 2 3 GND (+) Supply (+) Output Case ground Shunt cal STD. DIN 43650 (OPTION 6M) No shunt cal 1 2 3 4 (+) Excitation (+) Output (-) Output (-) Excitation With shunt cal (option 3d) Not Applicable 1.83 M [5 FT] INTEGRAL CABLE (OPTION 6Q) No shunt cal R Bl G W (+) Excitation (-) Excitation (-) Output (+) Output With shunt cal (option 3d) Not Applicable R Bl G W (+) Supply (-) Supply return (-) Output (+) Output 0 Vdc to 5 Vdc R Bl G W (+) Supply (-) Supply return (-) Output (+) Output 0 Vdc to 10 Vdc R Bl (+) Supply (+) Output 4 mA to 20 mA R Bl W (+) Supply (+) Output 4 mA to 20 mA Case ground R Bl G W (+) Supply (-) Supply return Shunt cal (+) Output 0 Vdc to 5 Vdc R Bl G W (+) Supply (-) Supply return Shunt cal (+) Output 0 Vdc to 10 Vdc R Bl G (+) Supply (+) Output 4 mA to 20 mA Shunt cal R Bl W G (+) Supply (+) Output 4 mA to 20 mA Case ground Shunt cal R Bl G W (+) Supply (-) Supply return (-) Output (+) Output 0 Vdc to 5 Vdc R Bl G W (+) Supply (-) Supply return (-) Output (+) Output 0 Vdc to 10 Vdc R Bl (+) Supply (+) Output 4 mA to 20 mA R Bl W (+) Supply (+) Output 4 mA to 20 mA Case ground R Bl G W (+) Supply (-) Supply return Shunt cal (+) Output 0 Vdc to 5 Vdc R Bl G W (+) Supply (-) Supply return Shunt cal (+) Output 0 Vdc to 10 Vdc R Bl G (+) Supply (+) Output 4 mA to 20 mA Shunt cal R Bl W G (+) Supply (+) Output 4 mA to 20 mA Case ground Shunt cal CONDUIT FITTING (OPTION 6R) No shunt cal R Bl G W (+) Excitation (-) Excitation (-) Output (+) Output With shunt cal (option 3d) Not Applicable Note: For wiring codes, R=red; Bl = black; W = white; G = green. Color specifies cable and letter or number specifies connection *** See Honeywell’s Web site (http://measurementsensors.honeywell.com) for most up-to-date information regarding Intrinsically Safe approvals ref. #008-0547-00. Sensing and Internet of Things 5 DIFFERENTIAL PRESSURE TRANSDUCER, MODEL FP2000 HOW TO ORDER The FP2000 Order Code is an easy way for you to order exactly what you want the factory to build. Simply make one selection in each of the six required categories. Choose adders and accessories only if you require them. By visiting our Web site at www.honeywell.com/sensing you can view complete technical specifications for the FP2000. Step 1 TRANSDUCER TYPE o o Unit type o psi o torr o mBar o kPa o bar o in Hg o mm Hg o in H2O Step 4 ADDERS o Enhanced thermals Differential: 0 °F to 180 °F o Shunt cal o CE rating o Zero and span adjustments Adder code 1y o mV/V o 5 Vdc o 10 Vdc o 4 mA to 20 mA (CE only) o 4 mA to 20 mA (IS and CE) 2u 2e 2f 2y 2n (2N) Step 3 PRESSURE RANGE OUTPUT Differential Range code Range code o 0.5 psi AN o 100 psi BR o 1 psi AP o 150 psi CJ o 2 psi AR o 200 psi CL o 2.5 psi AS o 250 psi CN o 5 psi AT o 300 psi CP o 10 psi AV o 400 psi CQ o 15 psi BJ o 500 psi CR o 25 psi BL o 600 psi CS o 30 psi BM o 750 psi CT o 50 psi BN o 1000 psi CV o 75 psi BP Type Code FDW FDD Differential - wet/wet Differential - wet/dry Step 2 ACCURACY o 0.10 % o 0.25 % 3d 9e 14c Accuracy code 1 2 Basic output code 2u 2d 2g 2p 2N If adding 1y, 3d, 9e or 14c 2u 2e 2f 2y 2y NOTE: If any ADDERS are required, the output code must be revised. See step 4. PRESSURE PORT o 1/4-18 NPT female o 1/4-18 NPT male o 7/16-20 UNF female o 7/16-20 UNF male o G 1/4 B female o G 1/4 B male o 1/8-27 NPT female o 1/8-27 NPT male o M12 x 1.5 male o M12 x 1.5 female o 9/16-18 UNF SAE male o 9/16-18 UNF SAE female Port code 5a 5b 5c 5d 5f 5g 5h 5i 5p 5q 5r 5s ELECTRICAL CONNECTOR o Bendix PTIH-10-6P o DIN 43650 o Mini DIN (40050) o Integral polyurethane 5-ft cable o 1/2 x 14 NPT conduit 5-ft cable exit NOTE: If you choose any adder output from step 4, you must revise your output code selection using this output code chart. IS outputs available only on ranges up to 5000 psi. ACCESSORIES Mating connectors only o Mini DIN o Bendix o mV/V o 5 Vdc o 10 Vdc o 4 mA to 20 mA o 4 mA to 20 mA (IS) Acc. code AA161 AA111 Connector code 6a 6m 6n 6q 6r Step 5 Mating conn. with 15 ft. cable for Bendix connector (6A) Without With shunt shunt (3d) o mV/V AA113 AA513 o 4 mA to 20 mA AA116 AA516 o 0 to 5/0 to 10 Vdc AA117 AA517 EXAMPLE ORDER CODE FDW 1 CN 1Y 2Y 5B 6A Selection Description Transducer type Accuracy Pressure range Adders Output Pressure port Electrical output connections Code Differential wet/wet 0.10 % 250 psi Enhanced temperature range 4 mA to 20 mA 1/4-18 NPT male Bendix PTIH-10-6P FDW 1 CN 1y 2y 5b 6a There must be a code in each of the six basic code boxes. If there are no adders or accessories chosen, leave the boxes blank. DESCRIPTION Order code BASIC CODE Type Accuracy ADDER CODE (SEE STEP 4) Range Output Pressure Elect. conn. Accessory code Zero and span adjustments are located on the side. See drawing for details. No zero and span adjustments are available on mV/V output option. 6 sensing.honeywell.com Extended Shunt cal. IS/CE rated Pots NOTES WARRANTY/REMEDY 1. Accuracies stated are expected for best-fit straight line for all errors, including linearity, hysteresis, and non-repeatability through zero. 2. For low pressure ranges, temperature effects may vary. 3. The wet/wet differential pressure transducer has two separate, welded Hastelloy diaphragms. In wet/dry unit, the wet port (high port) has all-welded stainless steel and Hastelloy construction. The dry port (low port) has no isolation diaphragm. 4. For differential pressure ranges at 0.10 % accuracy, non-amplified output @ 10 Vdc excitation = 100 mV. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. FOR MORE INFORMATION Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit sensing.honeywell.com or call: International +815 618 3231 USA/Canada +302 327 8920 Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 008835-6-EN | 6 | 09/19 © 2019 Honeywell International Inc. All rights reserved. m WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. m WARNING MISUSE OF DOCUMENTATION • • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury.
060-G626-05 价格&库存

很抱歉,暂时无法提供与“060-G626-05”相匹配的价格&库存,您可以联系我们找货

免费人工找货
060-G626-05
  •  国内价格
  • 1+12350.19708
  • 2+11875.13676

库存:2