MODEL FP5000
008927
Issue 2
Configurable Pressure Transducer
DESCRIPTION
The Honeywell Model FP5000 Series is
a media-isolated piezoresistive silicon
pressure sensor offering multiple
output options (0 V to 5 V,
0 V to 10 V or 4 mA to 20 mA) for
reading pressure over the specified fullscale pressure span and temperature
range. It is compensated for sensor
offset, sensitivity, temperature effects
and non-linearity to offer improved
thermal stability and accuracy.
Hastelloy® C276 and 316L stainless
steel wetted parts provide durability
with abrasive or corrosive media.
DIFFERENTIATION
• Offers improved accuracy and
reliability
• Configurable platform enables
a sensor to be built to customer
requirements. Simplified
nomenclature and order codes makes
ordering easier
• Many pressure and operating
temperature range options
• Built from stocked components; most
configurations are shipped within ten
business days
• Extensive history of pressure
measurement know-how
VALUE TO CUSTOMERS
• Built on the Honeywell history of
higher-quality pressure sensing
technologies
• Next-gen design of the popular
FP2000 pressure sensor
• Offers more repeatable, reliable, and
accurate pressure measurements over
time
• Rugged, stainless steel pressure
sensors are built and tested to perform
and survive in many demanding
environments
• Configurable platform creates a wide
range of standard configurations
• Stocked components enable shipping
within ten business days on most
configurations
FEATURES
• Pressure ranges from 10 in-H2O
[0.36 psi] up to 5000 psi
• Gage, absolute, vacuum, barometric
and compound pressure types
• Higher accuracy to 0.1 %FSS BFSL
• Multiple output types: 0 Vdc to 5 Vdc,
0 Vdc to 10 Vdc, 4 mA to 20 mA
• Multiple electrical and pressure
connection options
• Zero adjustment through
potentiometer
• Operating temperature ranges from
-40°C to 125°C [-40°F to 250°F]
• Multiple compensation temperature
ranges
APPLICATIONS
• Test stands (Automotive, Aerospace,
Industrial, and Medical)
• R&D test labs
• Hydraulic and pneumatic system
monitoring
• Leak detection
• Manufacturing mold pressure control
• Faster response and higher resolution
• Pump and compressor control
• Fully analog reduced-noise signal
path provides continuous output
resolution
• Liquid level measurement
• Oil & gas process control
• Stainless steel construction
• Ha C276 and 316L stainless steel
wetted parts offer more enhanced
durability with abrasive or corrosive
media
• CE approved
• Intrinsically Safe: cFMus, ATEX,
IEC Ex certified 2AR option (4 mA to
20 mA)
PORTFOLIO
Model FP5000 pressure
transducers are part of
a comprehensive line of
Honeywell pressure sensors.
CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000
TABLE 1. PERFORMANCE SPECIFICATIONS
TABLE 3. ELECTRICAL CONNECTORS
Characteristic
Measure
Connector
Operating Temperature Range
Sealing
Operating pressure
ranges
Gage: 10 in-H2O [0.36 psi] to 5000 psi
Absolute: 5 psi to 5000 psi
Vacuum: 10 in-H2O [0.36 psi] to 15 psi
Barometric: 0 to 30 in-Hg,
16 to 32 in-Hg, 26 to 32 in-Hg
Compound ranges available consult
factory
Equivalent ranges are available in other
pressure units also: kPa, bar, mm-Hg,
in-Hg, mbar, torr, in-H2O
PT-02A-10-6P
-40°C to 125°C [-40°F to 250°F]
IP67
DIN FORM A
-40°C to 125°C [-40°F to 250°F]
IP65
DIN FORM C
-40°C to 90°C [-40°F to 194°F]
IP65
Integral cable
-40°C to 105°C [-40°F to 221°F]
IP67
Conduit fitting
-40°C to 105°C [-40°F to 221°F]
IP67
M12 x 1, 4-pin
-40°C to 85°C [-40°F to 185°F]
IP67
Accuracy1,7
0.2 %FSS BFSL (Standard accuracy)
0.1 %FSS BFSL (High accuracy)
Output (selectable)
0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, or
4 mA to 20 mA (two wire)
Resolution
Continuous (Fully analog signal path)
TABLE 2. ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Operating temperature range
See Table 3 (Electrical connectors)
Compensated temperature
range
See Table 4 (Thermal effects error
band)
Thermal effects error band
(TEB)2,3
See Table 4 (Thermal effects error
band)
Sealing
See Table 3 (Electrical connectors)
Notes:
1. Accuracies stated are with respect to best fit straight line (BFSL)
for all errors including linearity, hysteresis, and non-repeatability
through zero.
2. Thermal Effects Error Band - The maximum deviation in output
due to changes in temperature over the entire compensated
temperature range, relative to output measured at reference
temperature. Includes all errors due to: Thermal Effect on Offset
and Thermal Effect on Span.
3. Thermal effects error band (TEB) increases pro-rata for pressure
ranges below 5 psi [0.35 bar].
4. True Zero Output: The voltage output versions have onboard circuitry that allows the output signal to swing all the way to ground
(True Zero) and even a little below (~-0.2 V). This mitigates
increased error at lower voltage measurements.
5. Over pressure: The absolute maximum rating for pressure which
may be safely applied to the product for it to remain in specification once pressure is returned to the operating pressure range.
Exposure to higher pressure may cause permanent damage to
the product.
6. Burst pressure: The maximum pressure that may be applied to
the product without causing escape of the pressure media. The
product should not be expected to function after exposure to any
pressure beyond the rated burst pressure.
7. All specifications apply at 25°C [77°F] and under operating conditions unless otherwise noted.
8. Full Scale Span (FSS): The algebraic difference between output
signal measured at the upper and lower limits of the operating
pressure range. Also known as “span”.
9. Offset: The output signal obtained when the reference pressure
is applied to all available pressure ports. Also known as “null” or
“zero”.
10. Reference pressure: The pressure used as a reference (zero) in
measuring product performance. Unless otherwise specified, this
is vacuum (0 psia) for absolute pressure sensors and local ambient atmospheric pressure (0 psig) for gage/vacuum pressure
sensors.
11. Minimum operating pressure: The lower limit of the operating
pressure range.
2 sensing.honeywell.com
TABLE 4. THERMAL EFFECTS ERROR BAND (TEB)
Compensated
Temperature Range
For Standard
Accuracy
For High
Accuracy
0° C to 60° C
[40° F to 140° F]
< ±0.75 %FSS
< ±0.5 %FSS
-20° C to 80° C
[0° F to 180° F]
< ±1.5 %FSS
< ±1 %FSS
-40° C to 85° C
[-40° F to 185° F]
< ±2.25 %FSS
< ±1.5 %FSS
-40° C to 125° C
[-40° F to 250° F]
< ±2.25 %FSS
< ±1.5 %FSS
TABLE 5. MECHANICAL SPECIFICATIONS
Characteristic
Measure
Media
Gas, liquid
Over pressure5
Operating ranges
≤ 15 psi (1 bar):
6X FS
15 psi (1 bar)
< Operating ranges
≤ 1000 psi (70 bar):
4X FS
1000 psi (70 bar)
< Operating ranges
≤ 5000 psi (350 bar):
3X FS or 10000 psi (700 bar)
whichever is less
Burst pressure6
Operating ranges
≤ 15 psi (1 bar):
10X FS
15 psi (1 bar)
< Operating ranges
≤ 1000 psi (70 bar):
6X FS
1000 psi (70 bar)
< Operating ranges
≤ 5000 psi (350 bar):
4X FS or 10000 psi (700 bar)
whichever is less
Weight (approx.)
150 g [5.3 oz]
Wetted parts material
Ha C276 and 316L stainless steel
Labels
Laser engraved
CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000
TABLE 6. ELECTRICAL SPECIFICATIONS7
Specifications
2AM, 2AR:
4 mA to 20 mA (2 wire)
2AN:
0 V to 5 V (3 wire)4
2AP:
0 V to 10 V (3 wire)4
Supply voltage
9 Vdc to 28 Vdc
9 Vdc to 28 Vdc
14 Vdc to 28 Vdc
Current consumption
4 mA to 24 mA
< 6 mA
< 6 mA
Output at minimum operating
pressure11 - (compound,
barometric)
4 mA ±0.5 %FSS
0 V ±0.5 %FSS
0 V ±0.5 %FSS
Full scale span (FSS)8
16 mA ±1 %FSS
5 V ±1 %FSS
10 V ±1 %FSS
Frequency response
3500 Hz
3500 Hz
3500 Hz
Reverse voltage protection
Yes, 28 V
Yes, 28 V
Yes, 28 V
Load impedance
< 950 Ohm at 28 V decreasing
linearly to 0 Ohm at 9 V
> 10K Ohms
> 10K Ohms
Output at reference pressure 10 (absolute, gage, vacuum)
Insulation resistance
>500 MOhm to case GND at 33 V
>500 MOhm to case GND at 33 V
>500 MOhm to case GND at 33 V
Overvoltage protection
>32 V
>32 V
>32 V
Power up time
< 1 sec
< 1 sec
< 1 sec
Zero adjustment potentiometer
Yes, > ±5 %FS adjustment,
accessible from top after
demounting connector
Yes, > ±5 %FS adjustment,
accessible from top after
demounting connector
Yes, > ±5 %FS adjustment,
accessible from top after
demounting connector
Sensing and Internet of Things
3
CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000
TABLE 7. DIN FORM A (6M), DIN FORM C (6BO) WIRING
STANDARD
PIN
ALTERNATIVE
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
Designation
Designation
Designation
Designation
1
(+) Supply
(+) Supply
(+) Supply
(+) Supply
2
(+) Output
(+) Output
(+) Output
Supply return/ (-) Output
3
No connection
Supply return/ (-) Output
No connection
(+) Output
E
No connection
No connection
Case GND
Case GND
TABLE 8. PT02A-10-6P, 6-PIN (6A) WIRING
STANDARD
PIN
ALTERNATIVE
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
Designation
Designation
Designation
Designation
A
(+) Supply
(+) Supply
(+) Supply
(+) Supply
B
No connection
Supply return
(+) Output
(+) Output
C
No connection
(-) Output
No connection
No connection
D
(+) Output
(+) Output
No connection
Supply return/ (-) Output
E
No connection
No connection
No connection
No connection
F
No connection
No connection
No connection
No connection
TABLE 9. INTEGRAL CABLE (6Q), CONDUIT FITTING (6R) WIRING
STANDARD
ALTERNATIVE
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
Designation
Designation
Designation
Designation
Red
(+) Supply
(+) Supply
(+) Supply
(+) Supply
Black
(+) Output
Supply return
Not available
Supply return/ (-) Output
Green
Not available
(-) Output
Not available
Not available
White
Not available
(+) Output
(+) Output
(+) Output
PIN
TABLE 10. M12 X 1, 4-PIN (6BJ) WIRING
STANDARD
ALTERNATIVE
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
4 mA to 20 mA
(2AM, 2AR)
0 V to 5 V/0 V to 10 V
(2AN, 2AP)
Designation
Designation
Designation
Designation
1
(+) Supply
(+) Supply
(+) Supply
(+) Supply
2
No connection
(+) Output
(+) Output
No connection
3
(+) Output
Supply return/ (-) Output
No connection
Supply return/ (-) Output
4
Case GND
Case GND
Case GND
(+) Output
PIN
TABLE 11. INTRINSICALLY SAFE APPROVALS FOR OPTION 2AR (NOT AVAILABLE ON 2AM, 2AN, 2AP)
Agency
Approvals
cFMus
Class I, Div 1, Groups A, B, C, D
Class I, Zone 0, AEx/Ex ia IIC T4/T5 Ga
Ta= -40°C to 40°C (T5), -40°C to 85°C (T4)
ATEX
II 1 G Ex ia IIC T4/T5 Ga
Ta= -40°C to 40°C (T5), -40°C to 85°C (T4)
IEC Ex
Ex ia IIC T4/T5 Ga
Ta= -40°C to 40°C (T5), -40°C to 85°C (T4)
See Honeywell’s website (http://sensing.honeywell.com) for up-to-date information regarding intrinsically safe approvals. Refer to Installation
manual #008-0751-00 for installation/wiring instructions, cautions and warnings.
4 sensing.honeywell.com
CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000
Figure 1. Product Nomenclature
NF
G
1
BR , 1AK , 2AM , 5F , 6M ,7BA
Calibration
Product Series
NF
5-point calibration at 77°F
FP5000 pressure transducer
9A
9-point calibration at 77°F
Type
G
A
V
B
C
Wiring
Gage
Absolute
7BA
7BB
Vacuum
Barometric (UG, UQ, UR only)
Standard
Alternative
Compound (consult factory)
Electrical Connection
Accuracy
1
2
*
6A
6M
6BO
6Q
6R
6BJ
0.10 %*
0.20 %
Not available in ranges < 2 psi
Range
KD
KF
KG
KH
KJ
KL
KM
KQ
KR
KS
KT
kPa
35 kPa
100 kPa
200 kPa
300 kPa
700 kPa
1000 kPa
1500 kPa
3000 kPa
5000 kPa
7000 kPa
10000 kPa
in-H2O
WA*
WC*
WE*
WG*
10 in-H2O
20 in-H2O
30 in-H2O
50 in-H2O
psi
bar
ME
MF
NA
MG
NB
MH
MI
MJ
NC
MK
ND
ML
NE
MY
NG
1 bar
2 bar
3.5 bar
5 bar
7 bar
10 bar
20 bar
30 bar
35 bar
50 bar
70 bar
100 bar
135 bar
200 bar
350 bar
in-Hg
UG 30 in-Hg
UQ 16-32 in-Hg
UR 26-32 in-Hg
More ranges are available.
Please consult Honeywell for options.
AN*
AP*
AT
AV
BJ
BL
BM
BN
BP
BR
CJ
CL
CN
CP
CQ
CR
CS
CT
CV
DJ
DL
DM
DN
DR
DIN A 43650, 4-pin
DIN C, 4-pin
Integral cable, 5 feet#
Conduit fitting with 5 feet# cable
M12 x 1 (IEC 61076-2-101 style AM), 4-pin
Consult factory for other cable lengths
#
0.5 psi
1 psi
5 psi
10 psi
15 psi
25 psi
30 psi
50 psi
75 psi
100 psi
150 psi
200 psi
250 psi
300 psi
400 psi
500 psi
600 psi
750 psi
1000 psi
1500 psi
2000 psi
2500 psi
3000 psi
5000 psi
* Not available in absolute pressure type
PT02A-10-6P, 6-pin
Pressure Port
5A
5B
5D
5F
5G
5P
5AE
5I
1/4-18 NPT female
1/4-18 NPT male
7/16-20 UNF male
G1/4 B female
G1/4 B male
M12 x 1.5 male
1/2-14 NPT male
1/8-27 NPT male
Output
2AM
2AN
2AP
2AR
4 mA to 20 mA
0 Vdc to 5 Vdc
0 Vdc to 10 Vdc
4 mA to 20 mA Intrinsically Safe
(see Table 11 for certifications)
Temperature Compensation
Ranges with blue highlight (greater than 100 kPa, 15 psi, 1 bar)
are NOT available in Vacuum.
1AK
1Y1
1AP1
1BA2
1
2
0°C to 60°C [40°F to 140°F]
-20°C to 80°C [0°F to 180°F]
-40°C to 85°C [-40°F to 185°F]
-40°C to 125°C [-40°F to 250°F]
1Y and 1AP not available for pressure ranges below 5 psi [0.35 bar]
1BA not available for pressure ranges below 50 psi [3.5 bar]
SAMPLE CATALOG LISTINGS
Order Code
Description
NFA1BM,1AK,2AP,5A,6A,7BA
Model FP5000; 0.10% accuracy; 30 psi absolute;
compensated across 0°C to 60°C [40°F to 140°F];
0 Vdc to 10 Vdc output; 1/4-18 NPT female port;
PT02A-10-6P 6-pin electrical connector; standard wiring
NFG2DR,1Y,2AR, 5G,6Q,7BB
Model FP5000; 0.20% accuracy; 5000 psi gage;
compensated across -20°C to 80°C [0°F to 180°F];
Intrinsically Safe 4 mA to 20 mA output; G 1/4 B male port;
5 ft long integral cable; alternative wiring
Sensing and Internet of Things
5
CONFIGURABLE PRESSURE TRANSDUCER, MODEL FP5000
Figure 2. Mounting Dimensions
ELECTRICAL TERMINATION
Code 6BO: 4-pin,
Micro DIN Form C
Code 6M: 4-pin,
Standard DIN 43650 Form A
Ø 31,8
[1.3]
Ø 31,8
[1.3]
10,4
[0.4]
26,0
[1.1]
Code 6Q: 4-conductor, vented, Code 6R: 4-conductor, vented, Code 6BJ: 4-pin M12 x 1
1/2-14 NPT conduit exit with
Integral cable
(IEC 61076-2-101) style AM
integral cable
Code 6A: 6-pin,
Bendix connector
7,9
[0.3]
18,2
[0.7]
8,8
[0.3]
21,3
[0.8]
10,4
[0.4]
Ø 31,8
[1.3]
Ø 25,0
[1.0]
8,8 [0.3]
Code 5F: G 1/4 B
female
Code 5A: 1/4-18 NPT
female
37,1
[1.5]
37,1
[1.5]
22,2
[0.9]
22,2
[0.9]
Code 5G: G 1/4 B male
15,1
[0.6]
22,2
[0.9]
22,2
[0.9]
6 sensing.honeywell.com
35,8
[1.4]
41,1
[1.6]
18,4
[0.7]
Code 5D: 7/16-20 UNF
male
16,8
[0.7]
27,2
[1.1]
Choose from
electrical termination code: 6BO, 6M, 6A, 6Q, 6BJ & 6R
Choose from
pressure ports:
Codes 5AE, 5G, 5P, 5B, 5D, or 5I
16,8
[0.7]
Code 5B: 1/4-18 NPT
male
10,4
[0.4]
Ø 25,0
[1.0]
Ø 25,0
[1.0]
Choose from pressure ports:
Codes 5F or 5A
PRESSURE
PORTS
Ø 31,8
[1.3]
Ø 31,8
[1.3]
Code 5AE: 1/2-14 NPT
male
18,0
[0.7]
Code 5P: M12 x 15 male Code 5I: 1/8-27 NPT
male
15,2
[0.6]
13,2
[0.5]
, CAUTION
m WARNING
•
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
PRODUCT DAMAGE DUE TO
MECHANICAL ISSUES
PERSONAL INJURY
Ensure torque specifications are determined for the
specific application. (Mating materials and thread
sealants can result in significantly different torque
values from one application to the next.)
• When using mating parts made of stainless steel, use
a thread sealant with anti-seize properties to prevent
thread galling. Ensure the sealant is rated for the
application.
• Use appropriate tools (such as an open-ended wrench
or deep-well socket) to install transducers.
• Always hand-start transducers into the hole to prevent
cross threading and damage.
• Ensure that torque is not applied to the electrical
connector.
• Ensure that the proper mating electrical connector
with a seal is used to connect the transducer. Improper
or damaged seals can compromise ingress protection,
leading to short circuits.
• To ensure proper environmental sealing and electrical
connections when using a connector, follow the
connector manufacturer’s installation guidelines.
• All terminal cavities must be sealed using the correct
wire gauge and seal combination.
• If only two leads are used, any additional terminal
cavities should be sealed per the connector
manufacturer’s installation guide.
• Honeywell recommends using a crimping tool for
crimping wires to the connector terminals.
• Contact the individual connector manufacturer for
connector wiring.
Failure to comply with these instructions could result in
product damage.
, NOTICE
Refer installation manual #008-0751-00 for installation/
wiring instructions, cautions and warnings related to
Intrinsically Safe FP5000 (option 2AR).
FOR MORE INFORMATION
Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications,
pricing, or the nearest Authorized Distributor,
visit sensing.honeywell.com or call:
USA/Canada
+302 327 8920
Latin America
+1 305 805 8188
Europe
+1 302 327 8920
Japan
+81 (0) 3-6730-7152
Singapore
+65 6355 2828
Greater China
+86 4006396841
Failure to comply with these instructions could result in
death or serious injury.
m WARNING
MISUSE OF DOCUMENTATION
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied
with each product.
Failure to comply with these instructions could result in
death or serious injury.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship during the
applicable warranty period. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgment or
consult your local sales office for specific warranty details.
If warranted goods are returned to Honeywell during the
period of coverage, Honeywell will repair or replace, at its
option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness
for a particular purpose. In no event shall Honeywell be
liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance
personally, through our literature and the Honeywell website,
it is buyer’s sole responsibility to determine the suitability of
the product in the application.
Specifications may change without notice. The information
we supply is believed to be accurate and reliable as of this
writing. However, Honeywell assumes no responsibility for
its use.
Honeywell
Sensing and Internet of Things
830 East Arapaho Road
Richardson, TX 75081
Hastelloy® is a registered trademark of Haynes International, Inc.
008927-2-EN | 2 | 06/20
© 2020 Honeywell International Inc.