0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2455R-100-73

2455R-100-73

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    HONEYWELL - 2455R-100-73 - Switch, Thermostat, SPST-NO/NC, 15A, Flange, Quick Connect

  • 数据手册
  • 价格&库存
2455R-100-73 数据手册
THERMOSTATS - COMMERCIAL Thermostats - Commercial Commercial thermostats include products for use in a wide array of small and major appliances, automotive applications, office copy machines, heat and smoke detectors and HVAC equipment. These snap-action thermostats include automatic or manual reset options, phenolic or ceramic housings, and a variety of mounting brackets and terminal options. NOTE: The products in this section do not follow the “how to use this catalogue” instructions provided in the catalogue introduction. Specific reference numbers are not given due to their custom nature. Please contact your local Honeywell sales office for ordering information. 2450R/2450HR/2455R Series Phenolic Automatic Reset Thermostats 2450HR 6,73 [0.265] A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product. These products are factory calibrated to the customer’s specification. Reset type: Amperage capacity: Housing material: Operating temperature range: Environmental exposure range: Automatic 15 A resistive max. Phenolic 0 °C to 150 °C [32 °F to 302 °F] 0 °C to 177 °C [32 °F to 350 °F] 2450R 2,36 [0.093] DIA. 1,57 [0.062] DEEP 13,94 [0.549] 12,34 9,12 [0.486] [0.359] 14,43 DIA. [0.568] 16,0 DIA. [0.630] SERIES NAME 2450HR Phenolic Automatic Reset Thermostat 2455R 14,43 DIA. [0.568] 9,63 [0.379] 16,0 DIA. [0.630] 14,43 DIA. [0.568] 11,91 [0.469] 0,51 [0.020] 16,0 DIA. [0.630] SERIES NAME 2450R Phenolic Automatic Reset Thermostat 0,51 [0.020] SERIES NAME 2455R Phenolic Automatic Reset Thermostat www.honeywell.com/sensing 27 THERMOSTATS - COMMERCIAL 2450RC/2450RCH/2455RC Series Ceramic Automatic Reset Thermostats 2450CM/2455RM Series Ceramic and Phenolic Manual Reset Thermostats A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product. A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. The circuit will stay open above room ambient temperature until the manual reset button is pressed. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product. Reset type: Amperage capacity: Housing material: Operating temperature range: Environmental exposure range: Reset type: Amperage capacity: Housing material: Operating temperature range: Automatic 15 A resistive max. Ceramic 0 °C to 260 °C [32 °F to 500 °F] –20 °C to 287 °C [0 °F to 550 °F] 2450RC 16,00 [0.379] Manual 15 A resistive max. Ceramic or phenolic 52 °C to 232 °C [125 °F to 450 °F] (ceramic) 52 °C to 150 °C [125 °F to 302 °F] (phenolic) Environmental exposure range: 10 °C to 260 °C [50 °F to 500 °F] (ceramic) 10 °C to 177 °C [50 °F to 350 °F] (phenolic) 2450CM 1,04 [0.041] MAX TRAVEL OF RESET BUTTON ON CONTACT OPENING 15,98 [0.629] 14,48 12,90 [0.570] [0.508] 9,63 [0.379] 14,43 DIA. [0.568] 9,55 9,04 [0.376] [0.356] 0,51 [0.020] 16,0 DIA. [0.630] SERIES NAME 2450RC Ceramic Automatic Reset Thermostat 0,51 [0.020] SERIES NAME 2450CM Ceramic Manual Reset Thermostat 2450RCH 2455RM 2,36 [0.093] DIA. 1,57 [0.062] DEEP 14,48 [0.570] 12,90 9,04 [0.508] [0.356] 14,43 DIA. [0.568] 16,0 DIA. [0.630] ENCLOSED DISK 1,04 [0.041] MAX TRAVEL OF RESET BUTTON ON CONTACT OPENING 2,77 DIA. RESET [0.109] BUTTON 15,88 ON CONTACT [0.625] CLOSING 14,43 DIA. [0.568] SERIES NAME 2450RCH Ceramic Automatic Reset Thermostat 11,91 [0.469] 16,0 DIA. [0.630] 2455RC SERIES NAME 2455RM Phenolic Manual Reset Thermostat 14,43 DIA. [0.568] 11,91 [0.469] 16,0 DIA. [0.630] 0,51 [0.020] SERIES NAME 2455RC Ceramic Automatic Reset Thermostat 28 www.honeywell.com/sensing 0,51 [0.020] THERMOSTATS - COMMERCIAL 2450A/2455A Series Heat Detection Thermostats 2450R/2450RCH/2455R/2455RC Series “One-shot” ½ in Thermostats The gold contacts open or close on a temperature rise of 47 °C to 107 °C [117 °F to 225 °F]. Products are designed for high limit applications where automatic reset is not desired. Reset type: Automatic Amperage capacity: 15 A resistive max. Housing material: Phenolic, epoxy-sealed cap and terminal Operating temperature range: 47 °C to 107 °C [117 °F to 225 °F] Environmental exposure range: 0 °C to 150 °C [32 °F to 302 ° F] Reset type: Amperage capacity: Housing material: Operating temperature range: 2450A None 15 A resistive max. ceramic or phenolic 52 °C to 260 °C [125 °F to 500 °F] (ceramic) 52 °C to 150 °C [125 °F to 302 °F] (phenolic) Environmental exposure range: 18 °C to 316 °C [0 °F to 600 °F] (ceramic) 18 °C to 177 °C [0 °F to 350 °F] (phenolic) 2450R 9,63 [0.379] 14,43 DIA. [0.568] 9,63 [0.379] 0,51 [0.020] 16,0 DIA. [0.630] SERIES NAME 2450A Heat Detection Thermostat 2455A 0,51 [0.020] SERIES NAME 2450R Phenolic “One-shot” ½ in Thermostat 11,91 [0.469] 2450RCH 2,36 [0.093] DIA. 1,57 [0.062] DEEP 0,51 [0.020] SERIES NAME 2455A Heat Detection Thermostat 14,48 [0.570] 12,90 9,04 [0.508] [0.356] 14,43 DIA. [0.568] 2455RBV Series Overmolded Automatic Reset Thermostats A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product. Reset type: Amperage capacity: Housing material: Operating temperature range: Environmental exposure range: Automatic 15 A resistive max. Ceramic or phenolic, epoxy overmold -12 °C to 105 °C [10 °F to 221 °F] -18 °C to 121 °C [0 °F to 250 °F] 16,0 DIA. [0.630] ENCLOSED DISK SERIES NAME 2450RCH Ceramic “One-shot” ½ in Thermostat 2455R 14,43 DIA. [0.568] 11,91 [0.469] 16,0 DIA. [0.630] 0,51 [0.020] 2455RBV AS REQUIRED SERIES NAME 2455R Phenolic “One-shot” ½ in Thermostat WIRE GAGE AND INSULATION AS REQUIRED AS REQUIRED 18,54 [0.730] 2455RC 14,43 DIA. [0.568] 11,91 [0.469] 16,0 DIA. [0.630] 17,27 DIA. [0.680] SERIES NAME 2455RBV Overmolded Automatic Reset Thermostat 0,51 [0.020] 0,51 [0.020] SERIES NAME 2455RC Ceramic “One-shot” ½ in Thermostat www.honeywell.com/sensing 29 THERMOSTATS - COMMERCIAL 2450R Series Annular Ring Cap Automatic Reset Thermostats 2450R Series Fully Sealed Thermostats A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product. Reset type: Amperage capacity: Housing material: Automatic 15 A resistive, 12 Vdc Phenolic, can be partially or totally sealed against water ingress Operating temperature range: -10 °C to 55 °C [14 °F to 131 °F] Environmental exposure range: -40 °C to 130 °C [-40 °F to 266 °F] Life Cycle Capability: 300 K at 12 Vdc, 10 A Low Temperature Differential: Down to 8 °C [46 °F] Switch Temperature Tolerance: ±3 °C A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Response to temperature changes is extremely rapid due to the inherently low mass of the disc and the small size of the product. Reset type: Amperage capacity: Housing material: Operating temperature range: Environmental exposure range: Life cycle capability: Low temperature differential: Switch temperature tolerance: Automatic 15 A resistive, 12 Vdc Phenolic housing, aluminium cap totally encapsulated in water resistant epoxy -10 °C to 55 °C [14 °F to 131 °F] -40 °C to 130 °C [-40 °F to 266 °F] 300 K at 12 Vdc, 10 A Down to 8 °C [46 °F] ±3 °C 16,1 MAX. [0.63] 14,43 DIA. [0.568] 9,63 [0.379] 16,0 DIA. [0.630] 11,5 [0.45] 0,51 [0.020] SERIES NAME 2450R Phenolic Annular Ring Cap Automatic Reset Thermostat 2450R/2455R Series Protected Thermostats A temperature-sensitive bimetal disc, electrically isolated from the switch, actuates the normally closed contacts. The contacts open when the surface or ambient temperatures increase to the operating snap point of the calibrated disc. Basic thermostat is protected from the environment by sealing it in a metal housing or encapsulating it in epoxy. Reset type: Amperage capacity: Housing material: Operating temperature range: Environmental exposure range: SERIES NAME 2450R Fully Sealed Thermostat Automatic 15 A resistive, 12 Vdc Brass, aluminium, stainless steel and epoxy 15 °C to 130 °C [59 °F to 266 °F] -40 °C to 155 °C [-40 °F to 311 °F] SERIES NAME 2450R Protected Thermostat 2455R Protected Thermostat 30 www.honeywell.com/sensing Bimetal Thermostats - Sensing and Control - Honeywell Automation and Control Solutions Temperature Sensors Bimetal Thermostats Thermal Cutoffs The Honeywell bimetal thermostat product line consists of Single-Pole, Single-Throw (SPST) hermetic and non-hermetic thermostats, including low-silhouette, logic level, auto reset, manual reset, one-shot, and subminiature thermostats and thermal switches. These products are also defined by their ability to reliably maintain precision temperature tolerances or high amperage electrical loads. They provide temperature control and overtemperature protection for the appliance, office automation, industrial, commercial aircraft and medical equipment industries. Search the Sensing and Control Interactive Catalog. Bimetal thermostats are snap-action devices designed to operate in extreme conditions, such as exposure to hazardous substances, dust particles and liquid immersion. Contacts are thermally and electrically isolated. Dust-proof performance is achieved by using a ceramic or phenolic base protected by a metal enclosure. A variety of custom configurations are available which provide environmental protection. All Sensing & Control Thermistors & Probes Thermostats >Redi-Temp Subminiature 3600 Series >Redi-Temp Series 3100 SPST Hermetic Series >Redi-Temp 3455 RC 15 AMP High Temp. Series >Bimetal Precision & Commercial Thermostats Select a product from one of the following bimetal categories: Products & Applications Thermal Products Glossary Precision Thermostats Commercial Thermostats Contact Us Request Free Literature Precision Thermostats Hermetic Thermostats Series 3100 Features Applications Tight temperature tolerances and differentials available 6 A 120 Vac rating Industrial glue guns Environmental exposure -62 ° C to 288 °C [-80 °F to 550 °F] Battery pack heater 3106 Gold alloy cross-point contacts for use in logic level circuits Tight temperature tolerances and differentials available Solid state control backup 3150 Low profile 7,7 mm [0.305 in] maximum design height 6 A 120Vac rating Commercial aircraft avionics Power supplies Tight temperature tolerances and differentials available Copy machine overheat protection Gold alloy cross-point contacts for use in logic level circuits Low profile 7,7 mm [0.305 in] maximum design height UL recognized and CSA certified Tight temperature tolerances and differentials available Dry circuit applications where space is limited 3156 Blood analyzers Custom Packaged Thermostats Series Features http://content.honeywell.com/sensing/prodinfo/thermostats/bimetalthermostat.asp (2 of 4)17/11/2005 09:56:24 Applications Search for product and support information. Advanced Search Bimetal Thermostats - Sensing and Control - Honeywell Automation and Control Solutions 3000 Customized probe length Heater control Custom probe materials Aircraft bleed air Duct sensing Liquid bath control Many termination/connector options Hydraulic oil temperature control Non-Hermetic Thermostats Series 3001, 3004 Features Low profile and lightweight (Model 3001) European approved (3004 only) Tight temperature tolerances and differentials available Applications Computers Office equipment Blood analyzers High Amperage Thermostats 15 A Series 3450, 3455R, 3455RBV 3450RC, 3455RC Features Applications Electrical rating to 15 A 120 Vac resistive UL recognized, CSA certified and European approved Single-pole, single-throw Power supplies Environmental exposure for the 3450 & 3455R -18 °C to 177 °C [0 °F to 350 °F] Environmental exposure for the 3455RBV -18 °C to 121 ° C [0 °F to 250 °F] Computers (where high amperage loads are present) High temperature environmental exposure -18 ° C to 288 °C [0 °F to 550 °F] Electrical rating to 15 A 120 Vac resistive UL recognized, CSA certified and European approved Single-pole, single-throw Communications equipment Computers (where high amperage loads are present) Medical equipment Communications equipment Medical equipment Appliances Manual Reset Thermostats Series 3455RM, 3450CM Features Manually resettable operation (reset button) Electrical rating to 15 A 120 Vac resistive UL recognized and CSA certified Environmental exposure 10 ° C to 177 °C [50 °F to 350 F] Applications Where automatic reset is not preferred Commercial Thermostats Phenolic Thermostats Series 2450R, 2450HR, 2455R Features Applications 15 A, 120 Vac; 10 A, 240 Vac Copy machines UL recognized, CSA certified and European approved Contacts are available for mV and mA applications Environmental exposure 0 °C to 177 °C [32 °F to 350 °F] Medical equipment http://content.honeywell.com/sensing/prodinfo/thermostats/bimetalthermostat.asp (3 of 4)17/11/2005 09:56:24 Power supplies Bimetal Thermostats - Sensing and Control - Honeywell Automation and Control Solutions Ceramic Thermostats Series 2450RC, 2450RCH, 2455RC Features 15 A 120 Vac; 10 A 240 Vac UL recognized, CSA certified and European approved Contacts are available for mV and mA applications Environmental Exposure 0 °C to 177 °C [32 °F to 350 °F] Applications Office automation products Table-top applications Industrial equipment Appliances Manual Reset Thermostats Series 2455RM, 2450CM Features 15 A, 120 Vac; 10 A, 240 Vac UL recognized, CSA certified and European approved Environmental Exposure for 2455RM -18 °C to 121 °C [0 ° F to 250 °F] Environmental exposure for 3450CM 10 °C to 260 °C [50 ° F to 500 °F] Applications Office automation products Medical equipment Overmolded Automatic Reset Thermostats Series 2455RBV Features 15 A ,120 Vac; 8.3 A, 240 Vac Applications Industrial equipment UL recognized, CSA certified and European approved Environmental exposure -18 ° C to 121 °C [0 °F to 250 °F] Heat Detection Thermostats Series 2450A, 2455RA Features UL recognized Applications Heat detection Environmental exposure 0 °C to 150 °C [32 °F to 302 °F] One-shot Thermostats Series 2450R, 2455R, 2450RC, 2455RC Features Applications 15 A, 120 Vac; 10 A, 240 Vac Automation equipment UL recognized, CSA certified and European approved Environmental exposure for 2450R & 2455R 0 °C to 177 ° C [32 °F to 350 °F] Environmental exposure for 2450RC & 2455RC 0 °C to 288 °C [32 °F to 550 °F] Tabletop appliances http://content.honeywell.com/sensing/prodinfo/thermostats/bimetalthermostat.asp (4 of 4)17/11/2005 09:56:24 ‘Permanent Stock’ of Thermostats Type 2455R • Functions: Open on Rising Temperature, and Close on Rising Temperature • Standard Mounting Bracket: B 203 S • Terminals: horizontal T 146 • Operating Temperatures in 10° C Steps. • Up to 15A and up to 250V AC • Silver contact system Part Number 2455R- 100-84 2455R- 100-72 2455R- 100-73 2455R- 100-85 2455R- 100-74 2455R- 100-75 2455R- 100-76 2455R- 100-77 2455R- 100-86 2455R- 100-98 2455R- 100-88 2455R- 100-89 2455RC- 9100-373 2455R- 100-78 2455R- 100-79 2455R- 100-92 2455R- 100-93 2455R- 100-94 2455R- 100-95 2455R- 100-96 Function Open Close °C +/-K °C +/-K 30 3 15 40 3 25 50 3 35 60 3 45 70 3 55 80 3 65 90 3 75 100 4 80 110 4 90 120 4 98 130 4 110 140 4 115 150 7 120 Close Open °C +/-K °C +/-K 50 3 35 6 60 3 45 6 80 3 65 6 90 3 75 6 100 4 80 7 120 4 100 7 140 4 115 8 Mounting Bracket B 203S 4 6 6 6 6 6 6 7 7 6 8 8 8 Terminals T 146
2455R-100-73 价格&库存

很抱歉,暂时无法提供与“2455R-100-73”相匹配的价格&库存,您可以联系我们找货

免费人工找货