Miniature Low Pressure Sensors
24PC Series, Uncompensated/Unamplified
0.5 psi to 250 psi
Datasheet
Miniature Low Pressure Sensors
The 24PC Series Miniature Pressure Sensors are small, cost-effective devices intended for use with wet or dry media.
These sensors feature proven sensing technology that uses a specialized piezoresistive micromachined sensing element
to offer high performance, reliability, and accuracy. Each sensor contains four active piezoresistors that form a Wheatstone
bridge. When pressure is applied, the resistance changes and the sensor provides a milliVolt output signal that is
proportional to the input pressure.
The low power 24PC sensors are designed to accommodate pressures from 0.5 psi to 250 psi and have an operating
temperature range of -40 ºC to 85 ºC [-40 ºF to 185 ºF].
The 24PC sensors have the flexibility to be excited with constant current or constant voltage. When driven by constant
current, the pressure sensor’s terminal voltage will rise with increasing temperature. The rise in voltage not only temperature
compensates the span but also provides an indication of the sensor’s temperature.
These sensors can accommodate a variety of wet and dry media that are compatible with polyphthalamide (PPA) plastics
and media seals specified in the Nomenclature and Order Guide (see Figure 2). The 24PC sensors are RoHS compliant.
They are designed and manufactured according to ISO 9001 standards.
What makes our sensors better?
24PCXXJ6G
• Wet/Wet capability (i.e., liquids on both ports)
• Selectable seals available to match media used
• Higher pressure ranges for use in high pressure applications
24PCXXH6D
• Wide variety of pressure port types
• Available in both SIP and DIP packages
24PCXXK2G
For all available configurations, see Table 4.
MINIATURE • WET/WET Capability • SELECTABLE SEALS
2
sensing.honeywell.com
Features
and Benefits
One sensor does the work of two!
True wet/wet differential media sensing
Provides liquid sensing in differential applications
Wide operating temperature range of -40 ºC to 85 ºC
[-40 ºF to 185 ºF]
Allows use in a wide variety of applications
By matching pressure ranges to the application, we optimize
resolution and improve system accuracy.
Variety of pressure ranges within 0.5 psi to 250 psi
Provides flexibility in customers’ pneumatic designs
Absolute, differential, and gage measurement types
Allows customers to choose the sensor that fits their application
Gives customers greater system flexibility in their designs.
Variety of pressure port Types and lead terminations
Provides application flexibility
Also available in SMT and flow-through package
styles
Provides added design flexibility
sensing.honeywell.com
3
Potential Applications
MEDICAL
OXygen Conentrators
May be used to measure the sieve bed pressure to optimize system performance
DENTAL CHAIRS
May be used to control the pneumatic pressure in the various dental instruments
HEMODIALYSIS
May be used to monitor the correct pressure to help ensure optimum blood
filtration
INDUSTRIAL
Water CONTROL VALVES
May be used to monitor the water consumption in homes and buildings
IRRIGATION EQUIPMENT
May be used to control the water pressure and flow being delivered
FILTER MONITORING
May be used to detect when the filters are clogged and need to be replaced
PRESSURE VALVES
May be used to measure and control pressure in industrial processes
AIR COMPRESSORS
May be used to control the pressure being delivered to the end user equipment
breathalizerS
May be used to measure the exhalation pressure to ensure proper breath analysis
4
sensing.honeywell.com
24PC Series, Uncompensated/Unamplified
Table 1. Absolute Maximum Ratings1
Characteristic
Min.
Typ.
Max.
Unit
Note
Supply voltage
2.5
10
12
Vdc
–
Input resistance
4
5
6
kOhm
–
Output resistance
4
5
6
kOhm
–
Time response
–
–
1
ms
2
Absolute maximum ratings are the extreme limits the device will withstand without damage.
1
Time required for the output to increase from 10% to 90% of span in response to a step change in input pressure from the specified min. to max.
operating pressure.
2
Table 2. Technical Specifications
Characteristic
Parameter
Operating temperature range:
without EPDM seals
with EPDM seals
-40 °C to 85 °C [-40 °F to 185 °F]
-20 °C to 85 °C [-4 °F to 185 °F]
Storage temperature range
-55 °C to100 °C [-67 °F to 212 °F]
Soldering terminal temperature/time
Vibration
Shock
Life
315 °C [599 °F] max./10 s max.
10 G at 20 Hz to 2000 Hz
100 G for 11 ms
1 million cycles min.
sensing.honeywell.com
5
Miniature Low Pressure Sensors
Table 3. Performance Characteristics (Vcc =10.00 ±0.01 Vdc; Ta = 25 °C [77 °F])
Operating Pressure Range
Characteristic
0 psi to
0.5 psi
0 psi to
1 psi
0 psi to
5 psi
0 psi to
15 psi
0 psi to
30 psi
0 psi to
100 psi
0 psi to
250 psi
Unit
Note
Typ.
Max.
Typ.
Max.
Typ.
Max.
Typ.
Max.
Typ.
Max.
Typ.
Max.
Typ.
Max.
Span
–
35
±10
–
45
±15
–
115
±30
–
225
±60
–
330
±90
–
225
±69
–
212
±68
mV
1
Null offset
–
0 ±30
–
0 ±30
–
0 ±30
–
0 ±30
–
0 ±30
–
0 ±30
–
0 ±30
mV
2
Linearity (Best
Fit Straight Line,
P2>P1)
±0.2
±1.0
±0.2
±1.0
±0.2
±1.0
±0.2
±1.0
±0.2
±1.0
±0.2
±1.0
±0.2
±1.0
%span
3
Null shift
(0 °C to 25 °C,
25 °C to 50 °C)
±1.0
–
±1.0
–
±1.0
–
±1.0
–
±1.0
–
±1.0
–
±1.0
–
mV
4
Span shift
(0 °C to 25 °C,
25 °C to 50 °C)
±5.0
–
±5.0
–
±5.0
–
±5.0
–
±5.0
–
±5.0
–
±5.0
–
%span
5
Repeatability
and hysteresis
±0.5
–
±0.5
–
±0.5
–
±0.5
–
±0.5
–
±0.5
–
±0.5
–
mV
6
Overpressure
–
20
–
20
–
20
–
45
–
60
–
200
–
250
psi
7
Span is the algebraic difference between the output signal measured at the upper and lower limits of the operating pressure range, where
Port 2 (P2)>Port 1 (P1).
1
2
The output signal obtained when zero pressure is applied to all available ports.
3
The maximum deviation of product output from a straight line fitted to the output measured over the specified operating pressure range, calculated
according to BFSL. The straight line is fitted along a set of points that minimizes the sum of the square of the deviations of each of the points (“leastsquares” method).
The maximum deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at a reference
temperature of 25 °C.
4
5
The maximum deviation in span due to changes in temperature over the compensated temperature range, relative to full-scale span measured at a
reference temperature of 25 °C.
6
Repeatability is the maximum difference between the output readings when the same pressure is applied consecutively, under the same operating
conditions, with pressure approaching from the same direction within the specified operating pressure range. Hysteresis is the maximum difference
between output readings when the same pressure is applied consecutively, under the same operating conditions, with pressure approaching from
opposite directions within the specified operating pressure range.
Overpressure is the maximum pressure that may safely be applied to the product for it to remain in specification once pressure is returned to the
operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all
available pressure ports at any temperature within the operating temperature range.
7
Figure 1. Circuit Diagram
PIN 1
VCC
PIN 2
OUTPUT
A
PIN 4
OUTPUT
B
PIN 3
GROUND
6
sensing.honeywell.com
Output “A” increases as P2 pressure increases.
Symbol
Description
Output “B” deceases as P2 pressure increases.
Vcc
supply
OUTPUT A
bridge positive output
GROUND
ground
OUTPUT B
bridge negative output
24PC Series Miniature Low Pressure Sensors, Uncompensated/Unamplified
24PC Series, Uncompensated/Unamplified
Figure 2. Nomenclature and Order Guide1, 4
For example, a 24PCBEJ6G catalog listing defines a 24PC Series Miniature Low Pressure Sensor, Uncompensated/Unamplified,
5 psi pressure range, EPDM seal material, needle pressure port type, 1 x 4 SIP, 15,2 mm [0.60 in] long termination configuration, with
normal polarity output and gage pressure measurement type.
24PC
B
Product Series Pressure Range
24PC Series
Miniature Low
Pressure Sensors,
Uncompensated/
Unamplified
E
J
Seal Material
Pressure Port Type
2G
Termination Configuration,
Output, Pressure
Measurement Type
A
1 psi
F
fluorosilicone
A
Straight
B
5 psi
E
EPDM
B
Barbed
C
15 psi
N
neoprene
C
Luer
D
30 psi
S
silicone
D
Modular
E
0.5 psi
H
M5 thread port
F
100 psi
I
90° (opposite Pin 1)
1G normal polarity, gage
G
250 psi
J
Needle
2G 2 x 2 DIP, normal polarity, gage
2
K
90° (toward Pin 1)
M
1/4-28 thread
S
Manifold mount
T
Long barbed
1 x 4 SIP, 15,2 mm [0.60 in] long,
6A normal polarity, absolute3
1 x 4 SIP, 15,2 mm [0.60 in] long,
6D normal polarity, differential
1 x 4 SIP, 15,2 mm [0.60 in] long,
6G normal polarity, gage
1 x 4 SIP, 10,2 mm [0.40 in] long,
Every combination may not be possible. Contact customer service.
1
2
Available in 0.5 psi, 1 psi, 5 psi and 15 psi pressure ranges only.
3
Absolute pressure sensors require pressure port types A or D.
Various wire harnesses with end connector options are available. Contact customer service.
4
Notes:
1. Every combination may not be possible. Contact customer service.
2. Available in 0.5 psi, 1 psi, 5 psi and 15 psi pressure ranges only.
3. Absolute pressure sensors require pressure port types A or D.
4. Various wire harnesses with end connector options are available. Contact cus
sensing.honeywell.com
7
Miniature Low Pressure Sensors
Table 4. All Available Standard Configurations (See Figure 2)
Termination Configuration, Output, Pressure Measurement Type
6A
A
Straight
Pressure Port Type
6G
1G
B
Barbed
N/A
C
Luer
N/A
N/A
H
M5
Thread
N/A
I
90°
(Opposite
Pin 1)
N/A
N/A
J
Needle
N/A
N/A
K
90°
(Toward
Pin 1)
N/A
N/A
M
1/4-28
Thread
N/A
S
Manifold
Mount
N/A
T
Long
Barbed
N/A
sensing.honeywell.com
2G
N/A
D
Modular
8
6D
N/A
N/A
24PC Series, Uncompensated/Unamplified
Figure 3. Mounting Dimensions (For Reference Only: mm/[in].)
24PCXXA6A
24PCXXA6D
12,7
[0.5]
1,2 DIA.
[0.05]
12,7
[0.5]
2X 6,4 DIA.
[0.25]
8,0
[0.32]
8,0
[0.315]
15,2
[0.60]
15,2
[0.60]
2,5
[0.10]
3X 2,5
[0.10]
PORT 2
2X 4,5
[0.18]
13,4
[0.53]
[ 0,4
0.02]
9,0
[0.35]
1,7
[0.07]
21,7
[0.85]
2X 5,1 DIA.
[0.20]
21,7
[0.85]
0,4
[0.02]
9,0
[0.35]
4X 1,0
[0.04]
2,5
[0.10]
PORT 2
4X 0,5
[0.02]
3X 2,5
[0.10]
4X 1,0
[0.04]
4X 0,5
[0.02]
6,4 DIA.
[0.25]
PORT 1
1,7
[0.07]
34,4
[1.35]
5,0 DIA.
[0.20]
24PCXXA6G
PORT 1
24PCXXA2G
12,7
[0.5]
1,9 DIA.
[0.07]
8,0
[0.32]
4 3 2 1
6,4 DIA.
[0.25]
3
12,7
[0.5]
4
1,9 DIA.
[0.07]
8,0
[0.32]
15,2
[0.60]
2
4X 1,0
[0.04]
2,5
[0.10]
PORT 2
6,4 DIA.
[0.25]
PORT 2
1
8,9
[0.35]
5,1 DIA.
[0.20]
21,7
[0.85]
27,8
[1.10]
21,7
[0.85]
9,0
[0.35]
4,5
[0.18]
9,0
[0.35]
2X 6,4 DIA.
[0.25]
4 3 2 1
4 3 2 1
4X 0,5
[0.02]
3X 2,5
[0.10]
2X 1,9 DIA.
[0.07]
0,4
[0.02]
1,7
[0.07]
4X 0,5
[0.02]
2,1
[0.08]
4X 1,0
[0.04]
2X 5
[0.20]
4X 0,4
[0.02]
2X 8
[0.31]
PORT 1
PORT 1
sensing.honeywell.com
9
Miniature Low Pressure Sensors
Figure 3. Mounting Dimensions (continued)
24PCXXB6D
24PCXXB6G
12,7
[0.5]
12,7
[0.5]
8,0
[0.32]
2,0 DIA.
[0.08]
8,0
[0.32]
4 3 2 1
15,2
[0.60]
4 3 2 1
15,2
[0.60]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
20,4
[0.80]
2,5
[0.10]
PORT 2
PORT 2
4,1 DIA.
[0.16]
0,4
[0.02]
4,4
[0.17]
2,5
[0.10]
3X 2,5
[0.10]
5,6
[0.22]
3,6
[0.14]
9,0
[0.35]
33,1
[1.30]
4,7 DIA.
[0.19]
4X 1,0
[0.04]
4X 0,5
[0.02]
3,2 DIA.
[0.13]
20,4
[0.80]
1,6
[0.06]
4,7 DIA.
[0.19]
5,6
[0.22]
3,6
[0.14]
0,4
[0.02]
9,0
[0.35]
1,6
[0.06]
6,4 DIA.
[0.25]
PORT 1
4,1 DIA.
[0.16]
5,0 DIA.
[0.20]
PORT 1
24PCXXB1G
24PCXXB2G
12,7
[0.5]
2,0 DIA.
[0.08]
8,0
[0.32]
10,2
[0.40]
3
4 3 2 1
4X 0,5
[0.02]
3X 2,5
[0.10]
3,6
[0.14]
2,0 DIA.
[0.08]
4
8,0
[0.32]
2
4X 1,0
[0.04]
1
PORT 2
2,5
[0.10]
PORT 2
20,4
[0.80]
12,7
[0.5]
4,7 DIA.
[0.19]
5,6
[0.22]
4,1 DIA.
[0.16]
0,4
[0.02]
9,0
[0.35]
3,2 DIA.
[0.13]
20,4
[0.80]
3,6
[0.14]
5,6
[0.22]
26,5
[1.04]
9,0
[0.35]
4X 0,5
[0.02]
1,6
[0.06]
2,0
[0.08]
4X 1,0
[0.04]
2X 5
[0.20]
PORT 1
PORT 1
10
sensing.honeywell.com
3,2 DIA.
[0.13]
4X 0,4
[0.02]
2X 8
[0.31]
3,2 DIA.
[0.13]
24PC Series, Uncompensated/Unamplified
Figure 3. Mounting Dimensions (continued)
24PCXXC6D
24PCXXC6G
12,7
[0.5]
12,7
[0.5]
8,0
[0.32]
1,2 DIA.
[0.05]
8,0
[0.32]
4 3 2 1
15,2
[0.60]
4 3 2 1
15,2
[0.60]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
2,5
[0.10]
4,6 DIA.
[0.18]
PORT 2
9,7
[0.38]
31,3
[1.23]
0,4
[0.02]
9,0
[0.35]
4,4
[0.17]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
3,9 DIA.
[0.15]
18,7
[0.74]
2,5
[0.10]
PORT 2
4,6 DIA.
[0.18]
9,7
[0.38]
0,4
[0.02]
9,0
[0.35]
1,7
[0.07]
1,7
[0.07]
6,4 DIA.
[0.25]
PORT 1
3,9 DIA.
[0.15]
5,0 DIA.
[0.20]
PORT 1
24PCXXC1G
24PCXXC2G
12,7
[0.5]
1,2 DIA.
[0.05]
3
8,0
[0.32]
10,2
[0.40]
4X 0,5
[0.02]
3X 2,5
[0.10]
18,7
[0.74]
1,2 DIA.
[0.05]
4
8,0
[0.32]
4 3 2 1
2
4X 1,0
[0.04]
2,5
[0.10]
PORT 2
1
PORT 2
3,9 DIA.
[0.15]
4,6 DIA.
[0.18]
9,7
[0.38]
9,0
[0.35]
12,7
[0.5]
18,7
[0.74]
3,9 DIA.
[0.15]
4,6 DIA.
[0.18]
9,7
[0.38]
24,8
[0.98]
9,0
[0.35]
0,4
[0.02]
4X 0,5
[0.02]
1,7
[0.07]
4X 1,0
[0.04]
2X 5
[0.20]
4X 0,4
[0.02]
2X 8
[0.31]
PORT 1
PORT 1
sensing.honeywell.com
11
Miniature Low Pressure Sensors
Figure 3. Mounting Dimensions (continued)
24PCXXD6A
24PCXXD6D
12,7
[0.5]
12,7
[0.5]
1,2 DIA.
[0.05]
8,0
[0.32]
1,2 DIA.
[0.05]
8,0
[0.32]
4 3 2 1
15,2
[0.60]
4 3 2 1
15,2
[0.60]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
2,5
[0.10]
PORT 2
1,7
[0.07]
2,5
[0.10]
PORT 2
0,4
[0.02]
9,0
[0.35]
0,4
[0.02]
9,0
[0.35]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
21,7
[0.85]
4,4
[0.17]
1,7
[0.07]
PORT 1
6,4 DIA.
[0.25]
5,0 DIA.
[0.20]
PORT 1
24PCXXD6G
24PCXXD2G
12,7
[0.5]
1,2 DIA.
[0.05]
8,0
[0.32]
3
4 3 2 1
15,2
[0.60]
9,0
[0.35]
2,5
[0.10]
9,0
[0.35]
PORT 2
0,4
[0.02]
PORT 1
sensing.honeywell.com
1,2 DIA.
[0.05]
1
PORT 2
4X 1,0
[0.04]
1,7
[0.07]
12
4
8,0
[0.32]
2
4X 0,5
[0.02]
3X 2,5
[0.10]
12,7
[0.5]
4X 0,5
[0.02]
0,59
[15.1]
2,0
[0.08]
4X 1,0
[0.04]
2X 5
[0.20]
PORT 1
4X 0,4
[0.02]
2X 8
[0.31]
24PC Series, Uncompensated/Unamplified
Figure 3. Mounting Dimensions (continued)
24PCXXH6D
12,7
[0.5]
24PCXXH6G
1,2 DIA.
[0.05]
8,0
[0.32]
12,7
[0.5]
4 3 2 1
8,0
[0.32]
15,2
[0.60]
3,6
[0.4]
10,2
[0.40]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
2,5
[0.10]
M5 X 0,8
21,7
[0.85]
4,4
[0.17]
34,4
[1.35]
2,5
[0.10]
4X 1,0
[0.04]
3X 2,5
[0.10]
3,6
[0.4]
0,4
[0.02]
9,0
[0.35]
4 3 2 1
4X 0,5
[0.02]
7,3 DIA.
[0.29]
PORT 2
1,1
[0.4]
1,2 DIA.
[0.05]
PORT 2
M5 X 0,8
1,1
[0.4]
21,7
[0.85]
1,7
[0.07]
0,4
[0.02]
9,0
[0.35]
6,4 DIA.
[0.25]
1,7
[0.07]
5,0 DIA.
[0.20]
PORT 1
PORT 1
24PCXXH1G
24PCXXH2G
12,7
[0.5]
1,2 DIA.
[0.05]
8,0
[0.32]
3
4 3 2 1
7,3 DIA.
[0.29]
3,6
[0.4]
1,1
[0.4]
21,7
[0.85]
9,0
[0.35]
4
1,2 DIA.
[0.05]
8,0
[0.32]
15,2
[0.60]
4X 0,5
[0.02]
3X 2,5
[0.10]
12,7
[0.5]
4X 1,0
[0.04]
1,1
[0.4]
2,5
[0.10]
PORT 2
7,3 DIA.
[0.29]
M5 X 0,8
0,4
[0.02]
21,7
[0.85]
1
PORT 2
M5 X 0,8
27,8
[1.09]
3,6
[0.4]
21,7
[0.85]
9,0
[0.35]
4X 0,5
[0.02]
1,7
[0.07]
2
4X 1,0
[0.04]
2X 5
[0.20]
4X 0,4
[0.02]
2X 8
[0.31]
PORT 1
PORT 1
sensing.honeywell.com
13
Miniature Low Pressure Sensors
Figure 3. Mounting Dimensions (continued)
24PCXXI6D
24PCXXI6G
5,1 DIA.
[0.20]
6,4 DIA.
[0.25]
4,1
[0.16]
36,2
[1.43]
5,1 DIA.
[0.20]
6,4 DIA.
[0.25]
4,1
[0.16]
36,2
[1.43]
8,0
[0.32]
8,0
[0.32]
4 3 2 1
4 3 2 1
15,2
[0.60]
15,2
[0.60]
2,5
[0.10]
4X 0,5
[0.02]
3X 2,5
[0.10]
4X 1,0
[0.04]
7,0
[0.28]
14,5
[0.57]
2,9
[0.11]
1,6
[0.06]
0,4
[0.02]
9,0
[0.35]
27,2
[1.07]
2,5
[0.10]
4X 0,5
[0.02]
3X 2,5
[0.10]
PORT 2
1,6
[0.06]
4X 1,0
[0.04]
7,0
[0.28]
2,0 DIA.
[0.08]
1,7
[0.07]
14,5
[0.57]
4,4
[0.17]
2,9
[0.11]
0,4
[0.02]
9,0
[0.35]
6,4 DIA.
[0.25]
PORT 1
1,6
[0.06]
PORT 2
1,6
[0.06]
2,0 DIA.
[0.08]
1,7
[0.07]
5,0 DIA.
[0.20]
PORT 1
24PCXXJ6D
24PCXXJ6G
12,7
[0.5]
0,6 DIA.
[0.02]
12,7
[0.5]
8,0
[0.32]
8,0
[0.32]
4 3 2 1
15,2
[0.60]
4X 0,5
[0.02]
3X 2,5
[0.10]
4 3 2 1
15,2
[0.60]
4X 1,0
[0.04]
2,5
[0.10]
1,9 DIA.
[0.07]
PORT 2
6,4 DIA.
[0.25]
4X 0,5
[0.02]
3X 2,5
[0.10]
22,1
[0.87]
4X 1,0
[0.04]
2,5
[0.10]
PORT 2
1,9 DIA.
[0.07]
6,4 DIA.
[0.25]
22,1
[0.87]
0,4
[0.02]
9,0
[0.35]
34,8
[1.37]
0,6 DIA.
[0.02]
4,4
[0.17]
PORT 1
0,4
[0.02]
9,0
[0.35]
1,6
[0.06]
6,4 DIA.
[0.25]
1,6
[0.06]
5,0 DIA.
[0.20]
PORT 1
14
sensing.honeywell.com
24PC Series, Uncompensated/Unamplified
Figure 3. Mounting Dimensions (continued)
24PCXXJ2G
24PCXXK6D
8,0
[0.315]
3
12,7
[0.5]
4
4,1
[0.16]
15,2
[0.60]
0,6 DIA.
[0.02]
8,0
[0.32]
2
1
PORT 2
6,4 DIA.
[0.25]
22,1
[0.87]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
1,9 DIA.
[0.07]
2,5
[0.10]
7,0
[0.28]
28,2
[1.11]
14,5
[0.57]
9,0
[0.35]
21,0
[0.83]
9,0
[0.35]
2,9
[0.11]
PORT 2
2,0 DIA
[0.08]
1,7
[0.07]
4,4
[0.17]
4X 1,0
[0.04]
2X 5
[0.20]
1,6
[0.06]
0,4
[0.02]
27,2
[1.07]
4X 0,5
[0.02]
6,4 DIA.
[0.25]
1,6
5,1 DIA.
[0.06]
[0.20]
4X 0,4
[0.02]
2X 8
[0.31]
6,4 DIA.
[0.25]
PORT 1
4 3 2 1
5,0 DIA.
[0.20]
PORT 1
24PCXXK6G
24PCXXK2G
12,7
[0.5]
8,0
[0.32]
8,0
[0.315]
21,0
[0.83]
4,1
[0.16]
4,1
[0.16]
15,2
[0.60]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
2,5
[0.10]
7,0
[0.28]
14,5
[0.57]
7,0
[0.28]
9,0
[0.35]
2,9
[0.11]
PORT 2
2,0 DIA.
[0.08]
0,4
[0.02]
6,4 DIA.
[0.25]
1,6
5,1 DIA.
[0.06]
[0.20]
14,5
[0.57]
1,6
[0.06]
2,9
[0.11]
PORT 2
6,4 DIA.
[0.25]
1,6
,1 DIA.
[0.06]
5
[0.20]
1,6
[0.06]
9,0
[0.35]
20,6
[0.81]
4X 1,0
[0.04]
2X 5
[0.20]
4X 0,5
[0.02]
1,7
[0.07]
4 3 2 1
13,6
[0.51]
4X 0,4
[0.02]
2X 8
[0.31]
5,0 DIA.
[0.20]
PORT 1
2
1
3
4
6,4 DIA.
[0.25]
sensing.honeywell.com
15
Miniature Low Pressure Sensors
Figure 3. Mounting Dimensions (continued)
12,7
[0.5]
24PCXM6D
24PCXXM6G
1,2 DIA.
[0.05]
12,7
[0.5]
8,0
[0.32]
1,2 DIA.
[0.05]
8,0
[0.32]
4 3 2 1
15,2
[0.60]
4 3 2 1
15,2
[0.60]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
2,5
[0.10]
PORT 2
9,1 DIA.
[0.36]
¼-28 UNF
2,5
[0.10]
PORT 2
1,8
[0.07]
3,6
[0.4]
7,1 DIA.
[0.30]
0,4
[0.02]
9,0
[0.35]
4,4
[0.17]
9,1 DIA.
[0.36]
¼-28 UNF
3,2
[0.13]
24,0
[0.94]
36,7
[1.44]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
1,8
[0.07]
3,6
[0.4]
3,2
[0.13]
24,0
[0.94]
0,4
[0.02]
9,0
[0.35]
1,7
[0.07]
1,7
[0.07]
6,4 DIA.
[0.25]
PORT 1
7,1 DIA.
[0.30]
5,0 DIA.
[0.20]
PORT 1
24PCXXM1G
24PCXXM2G
12,7
[0.5]
1,2 DIA.
[0.05]
8,0
[0.32]
10,2
[0.40]
3
3X 2,5
[0.10]
3,6
[0.4]
1,1
[0.4]
21,7
[0.85]
9,0
[0.35]
4
8,0
[0.32]
4 3 2 1
4X 0,5
[0.02]
12,7
[0.5]
2
2,5
[0.10]
4X 1,0
[0.04]
24,0
[0.94]
PORT 2
1
1,2 DIA.
[0.05]
¼-28 UNF
3,6
[0.4]
M5 X 0,8
1,8
[0.07]
3,2
[0.13]
0,4
[0.02]
4X 0,5
[0.02]
4X 1,0
[0.04]
2X 5
[0.20]
PORT 1
PORT 1
sensing.honeywell.com
7,1 DIA.
[0.30]
9,0
[0.35]
1,7
[0.07]
16
9,1 DIA.
[0.36]
PORT 2
4X 0,4
[0.02]
2X 8
[0.31]
24PC Series, Uncompensated/Unamplified
Figure 3. Mounting Dimensions (continued)
24PCXX6SD
24PCXXS6G
12,7
[0.5]
1,2 DIA.
[0.05]
12,7
[0.5]
8,0
[0.32]
8,0
[0.32]
6,3 DIA.
[0.25]
4 3 2 1
4 3 2 1
15,2
[0.60]
4X 1,0
[0.04]
2,5
[0.10]
2,5
[0.10]
9,1 DIA.
[0.36]
PORT 2
1,3
[0.05]
0,4
[0.02]
9,0
[0.35]
4,4
[0.17]
4X 1,0
[0.04]
4X 0,5
[0.02]
3X 2,5
[0.10]
9,1 DIA.
[0.36]
PORT 2
26,54
[1.04]
6,3 DIA.
[0.25]
15,2
[0.60]
4X 0,5
[0.02]
3X 2,5
[0.10]
13,9
[0.55]
1,2 DIA.
[0.05]
1,3
[0.05]
1,7
[0.07]
13,9
[0.55]
9,0
[0.35]
0,4
[0.02]
1,7
[0.07]
6,4 DIA.
[0.25]
PORT 1
5,0 DIA.
[0.20]
PORT 1
24PCXXS1G
24PCXXS2G
12,7
[0.5]
1,2 DIA.
[0.05]
8,0
[0.32]
10,2
[0.40]
3
4
1,2 DIA.
[0.05]
8,0
[0.32]
6,3 DIA.
[0.25]
4 3 2 1
12,7
[0.5]
2
1
6,3 DIA.
[0.25]
PORT 2
4X 0,5
[0.02]
3X 2,5
[0.10]
13,9
[0.55]
4X 1,0
[0.04]
PORT 2
9,1 DIA.
[0.36]
1,8
[0.07]
6,3 DIA.
[0.25]
5,1 DIA.
[0.20]
9,0
[0.35]
1,3
[0.05]
13,9
[0.55]
2,5
[0.10]
0,4
[0.02]
9,1 DIA.
[0.36]
9,0
[0.35]
4X 0,5
[0.02]
4X 1,0
[0.04]
2X 5
[0.20]
4X 0,4
[0.02]
2X 8
[0.31]
1,7
[0.07]
PORT 1
sensing.honeywell.com
17
Miniature Low Pressure Sensors
Figure 3. Mounting Dimensions (continued)
24PCXXT6D
24PCXXT6G
12,7
[0.5]
12,7
[0.5]
8,0
[0.32]
8,0
[0.32]
4 3 2 1
4 3 2 1
15,2
[0.60]
15,2
[0.60]
4X 0,5
[0.02]
3X 2,5
[0.10]
28,0
[1.10]
4X 1,0
[0.04]
2,5
[0.10]
PORT 2
4,7 DIA.
[0.19]
1,8
[0.07]
4,1 DIA.
[0.16]
11,2
[0.44]
0,4
[0.02]
9,0
[0.35]
4X 1,0
[0.04]
2,5
[0.10]
PORT 2
4,7 DIA.
[0.19]
1,8
[0.07]
28,0
[1.10]
40,7
[1.60]
4,4
[0.17]
4X 0,5
[0.02]
3X 2,5
[0.10]
3,2 DIA.
[0.13]
4,1 DIA.
[0.16]
11,2
[0.44]
1,6
[0.06]
0,4
[0.02]
9,0
[0.35]
6,4 DIA.
[0.25]
PORT 1
1,6
[0.06]
5,0 DIA.
[0.20]
PORT 1
24PCXXT2G
3
12,7
[0.5]
4
8,0
[0.32]
2
1
1,2 DIA.
[0.057]
PORT 2
1,8
[0.07]
28,0
[1.10]
11,2
[0.44]
4,7 DIA.
[0.19]
3,2 DIA.
[0.13]
4,1 DIA.
[0.16]
9,0
[0.35]
4X 0,5
[0.02]
4X 1,0
[0.04]
2X 5
[0.20]
PORT 1
18
sensing.honeywell.com
4X 0,4
[0.02]
2X 8
[0.31]
3,2 DIA.
[0.13]
ADDITIONAL INFORMATION
The following associated literature is available at sensing.honeywell.com:
• Product Line Guide
• Product Range Guide
• Product Installation Instructions
• Application-Specific Information
• Technical Notes
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with each
product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847 or
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items it finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness for
a particular purpose. In no event shall Honeywell be liable
for consequential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
32302909-A-EN IL50
February 2015
© 2015 Honeywell International Inc. All rights reserved.