Magnetoresistive Sensor ICs
005987
2SS52M Series
Issue 2
Datasheet
2SS52M-T2
2SS52M-T3
2SS52M
2SS52M-S
SS552MT
DESCRIPTION
The 2SS52M Series Digital Magnetoresistive Sensors are
omnipolar, solid-state sensors with a built-in magnetoresistive
bridge integrated on silicon and encapsulated in a plastic
package. The integrated circuit also includes a band-gap
regulator and a digital output in response to very low magnetic
fields.
These sensor ICs may be operated with either a North or a
South magnetic pole applied in parallel to the sensor IC. The
polarity does not need to be identified, simplifying installation in
single pole applications and doubling the resolution in rotating
magnet applications.
These small and highly sensitive omnipolar devices have
become a popular building block for flow metering, motor RPM
and cylinder position sensing.
They are available in five package styles:
• 2SS52M: U-pack, 3-pin, in-line sensor IC with straight leads
supplied in bulk packaging (1000 units per bag)
• SS552MT: SOT-89B surface-mount sensor IC supplied on
tape and reel which allows for compact design with automated
component placement (1000 units per tape and reel)
• 2SS52M-S: U-pack, 3-pin in-line, surface-mount sensor IC
supplied in bulk packaging (1000 units per bag)
• 2SS52M-T2: U-pack, 3-pin, in-line sensor IC with formed
leads supplied in ammo pack tape-in-box (5000 units per box)
• 2SS52M-T3: U-pack, 3-pin, in-line sensor IC with straight
leads supplied in ammo pack tape-in-box (5000 units per box)
Sensing and Productivity Solutions
FEATURES
• High sensitivity: 25 Gauss maximum operate point allows for
extended sensing distance or a smaller magnet
• 3.8 Vdc to 30 Vdc supply voltage range
• Omnipolar sensing: Activates with either North or South pole
• Temperature range: -40 °C to 150 °C [-40 °F to 302 °F]
• Digital current-sinking output
• RoHs compliant, meets Directive 2002/95/EC
POTENTIAL APPLICATIONS
Industrial
• High frequency flow sensing in HVAC, water, fuel meters, and
gas utility meters
• Anti-tamper detection in water, electric, and gas utility meters
• Liquid level detection
• Motor RPM sensing
• In-cylinder position sensing
Medical
• RPM sensing in exercise and rehabilitation equipment
• Magnetic interrupt in exercise and rehabilitation equipment
• Absence/presence detection in infusion pumps
• Position sensing of medication dispensing cabinet drawers
• Incline position sensing in hospital beds
White goods
• Lid, door and drawer position detection
• Fluid flow detection
• Liquid level detection
PORTFOLIO
The 2SS52M Series is part of Honeywell’s family of Digital
Magnetoresistive Sensor ICs:
• SM351LT, SM353LT
• SM351RT, SM353RT, SM451R, SM453R
Magnetoresistive Sensor ICs
2SS52M Series
Table 1. Electrical and Environmental Specifications
(At Vsupply = 3.8 Vdc to 30 Vdc, TA = -40 ºC to 150 ºC [-40 ºF to 302 ºF] except where otherwise specified.)
Characteristic
Condition
Min.
Typ.
Max.
Unit
Supply voltage
no load
3.8
—
30
Vdc
Supply current:
operated
released
24 °C ±2 °C, 16 Vdc ±0.5 % Vsupply
24 °C ±2 °C, 16 Vdc ±0.5 % Vsupply
—
—
6
6
11
10
mA
—
—
—
10.0
μA
sinking, 20 mA max.
—
0.25
0.40
V
1600 Ohm, 20 pF load
1600 Ohm, 20 pF load
—
—
0.2
0.1
1.5
1.5
μs
—
-40 [-40]
—
150 [302]
°C [°F]
Output leakage current (released)
Output voltage (operated)
Outptut switching time:
rise (10 % to 90 %)
fall (90 % to 10 %
Operating temperature range
Soldering temperature and time:
SS552MT
all other catalog listings
infrared reflow process: peak temperature 245 °C [473 °F] for 10 s max.
wave soldering process: 250 °C to 260 °C [482 °F to 500 °F] for 3 s max.
Table 2. Magnetic Characteristics (At Vsupply = 3.8 Vdc to 30 Vdc.)
Temperature Range
Operate
Release
Differential
Minimum
Maximum
Minimum
Minimum
Maximum
-20 °C to 85 °C [-4 °F to 185 °F]
—
25 Gauss
5 Gauss
—
7 Gauss
-40 °C to 150 °C [-40 °F to 302 °F]
—
25 Gauss
4 Gauss
—
8 Gauss
Table 3. Absolute Maximum Specifications
Characteristic
Min.
Typ.
Max.
Unit
Supply voltage
-0.5
—
30
Vdc
Voltage externally applied to output:
OFF condition only
OFF or ON condition
—
-0.5
—
—
30
—
Vdc
Output current
Storage temperature
Magnetic flux
—
—
20
mA
-40 [-40]
—
150 [302]
°C [°F]
—
—
no limit
Gauss
NOTICE
Absolute maximum ratings are the extreme limits the device will withstand
without damage to the device. Electrical and mechanical characteristics are
not guaranteed as maximum limits (above recommended operting conditions)
are approached, nor will the device necessarily operate at absolute maximum ratings.
CAUTION
ELECTROSTATIC
SENSITIVE
DEVICES
DO NOT OPEN OR HANDLE
EXCEPT AT A
STATIC FREE WORKSTATION
ESD SENSITIVITY:
CLASS 2
2
sensing.honeywell.com
Magnetoresistive Sensor ICs
2SS52M Series
Figure 1. Block Diagram for Current Sinking Output (NPN)
Vsupply (+)
Output (0) N.H.
Magnetoresistive
sensor
Trigger circuit
and amplifier
Ground (-)
Figure 2. Magnet Alignment to the Sensor IC
All Other Catalog Listings
SS552MT
(2SS52M shown)
S
N
S
N
N
S
OR
OR
N
S
• Operated by magnetic fields (North or South pole) that are parallel to the sensor IC; arrows indicate direction of magnetic flux.
• Due to the inherent high sensitivity of these sensor ICs, stray magnetic fields that are parallel to the sensor IC may affect operation.
Sensing and Productivity Solutions
3
Magnetoresistive Sensor ICs
2SS52M Series
Figure 3. Mounting Dimensions (For reference only. mm/in.)
2SS52M
Sensor IC
SS522MT
Sensor IC
4,52
[0.178]
1,57
[0.062]
1,70
[0.067]
0,15
[0.006]
3,05
[0.120]
2SSM
2,49
[0.098]
4,52
[0.178]
4,17
[0.164]
2,39
[0.094]
(+)
0,051
[0.002]
Magnetic Sensor
(-)
3X 0,41
[0.016]
3X 0,150
[0.059]
1,37
[0.054]
(0)
4,39
[0.173]
4,50
[0.177]
14,99
[0.59]
(-)
3X 0,38
[0.015]
(0)
(+)
3X 0,43 Max.
[0.017]
2X 1,27
[0.050]
0,76
[0.030]
3X 0,38
[0.015]
7,98
[0.314]
SS522MT
Tape and Reel
1,41 Max.
[0.016]
5,84 Max.
[0.230]
2,01
[0.079]
2,31 Max.
[0.091]
[0.059]
0,10 Max.
[0.004]
5,51
[0.217]
Top cover tape
11,99
[0.472]
5,00
[0.197]
A
4,60
[0.181]
Section A-A
[0.512]
1,75
[0.069]
ø1,50
A
1,91
[0.075]
ø13,00
3,99
[0.157]
8,00
[0.315]
12,19
[0.480]
3X 1,50 Min.
[0.059]
ø33,02
13,39 Max.
[0.724]
Measured at hub
[1.300]
ø50,04 Min.
[1.970]
ø178,05
[7.01]
Direction of feed from reel
4
sensing.honeywell.com
Magnetoresistive Sensor ICs
2SS52M Series
Figure 3. Mounting Dimensions (continued)
2SS52M-S
Sensor IC
4,52
[0.178]
1,57
[0.062]
3,05
[0.120]
2SSM
3X 0,38
[0.015]
(0)
(-)
(+)
3X 0,43 Max.
[0.017]
3X 0,38
[0.015]
1,52
[0.06]
3X 0,38
[0.015]
2X 1,27
[0.050]
2SS52M-T2
Ammo pack tape-in-box
Adhesive Tape
16,00
[0.63]
Sensor IC 24
Sensor IC 1
0,51 Max.
[0.020]
Fold
24,05
[0.947]
2,54 Min.
[0.100]
Sensor IC 1
5,97
[0.235]
8,99
[0.354]
18,01
[0.709]
Fold
6,35
[0.250]
12,7
[0.500]
ø3,99
2,54 Typ.
[0.100]
[0.157]
2SS52M-T3
Ammo pack tape-in-box
Adhesive Tape
Sensor IC 24
Sensor IC 1
0,51 Max.
[0.020]
24,05
[0.947]
2,54 Min.
[0.100]
Fold
Sensor IC 1
5,97
[0.235]
8,99
[0.354]
18,01
[0.709]
Fold
6,35
[0.250]
1,27 Typ.
[0.050]
12,7
[0.500]
ø3,99
[0.157]
Sensing and Productivity Solutions
5
Magnetoresistive Sensor ICs
2SS52M Series
Table 4. Order Guide
Catalog Listing
2SS52M
6
Description
Magnetoresistive sensor IC, omnipolar, U-pack, straight leads 14,99 mm
[0.590 in] long, bulk packaging (1000 units per bag)
SS552MT
Magnetoresistive sensor IC, omnipolar, SOT-89B surface-mount package,
tape and reel packaging (1000 units per reel)
2SS52M-S
Magnetoresistive sensor IC, omnipolar, U-pack, surface-mount package,
bulk packaging (1000 units per bag)
2SS52M-T2
Magnetoresistive sensor IC, omnipolar, U-pack, formed leads 14,99 mm
[0.590 in] long, ammo pack tape-in-box packaging (5000 units per box)
2SS52M-T3
Magnetoresistive sensor IC, omnipolar, U-pack, straight leads 14,99 mm
[0.590 in] long, ammo pack tape-in-box packaging (5000 units per box)
sensing.honeywell.com
ADDITIONAL MATERIALS
The following associated literature is available on the Honeywell
website at sensing.honeywell.com:
• Product line guide
• Product range guide
• SS552MT installation instructions
• Magnetic sensor IC selection chart
• Application Notes:
• Technical Notes:
- Solid-State Sensors Glossary of Terms
- Interpreting Operating Characteristics for
Solid-State Sensors
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
- Magnetoresistive sensors: Position and solid state sensor
- Blood Recovery System
m WARNING
m WARNING
MISUSE OF DOCUMENTATION
•
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Warranty/Remedy
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgement
or consult your local sales office for specific warranty details. If
warranted goods are returned to Honeywell during the period of
coverage, Honeywell will repair or replace, at its option, without
charge those items it finds defective. The foregoing is buyer’s
sole remedy and is in lieu of all other warranties, expressed
or implied, including those of merchantability and fitness for
a particular purpose. In no event shall Honeywell be liable for
consequential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
your local sales office.
To learn more about Honeywell’s
sensing and switching products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com, or
e-mail inquiries to
info.sc@honeywell.com
Honeywell Sensing and Productivity
Solutions
9680 Old Bailes Road
Fort Mill, SC 29707
honeywell.com
005987-2-EN IL50
April 2016
© 2016 Honeywell International Inc. All rights reserved.