Sensors and Switches
SENSING AND CONTROL
Product Catalog
Glo_Comm_minicat_Iss3_FINAL .PMD
1
1/10/2006, 3:43 PM
INTRODUCTION
SENSORS AND SWITCHES
Honeywell offers a wide selection of products and technology capability for applications in medical devices and equipment; heating, ventilation, airconditioning and refrigeration; information technology; home appliances; motor control and automotive passenger cars. This catalogue contains a
selection of our most popular, established product listings. To view our complete range of products, visit our web site at www.honeywell.com/
sensing.
How to use this catalogue
Honeywell – delivering excellence
For each referenced listing, key specification parameters, descriptions and
mounting drawing information are presented. These listings illustrate our
capabilities while the specifications included allow easy differentiation between
similar products. For products with no specific reference numbers,
please contact your local Honeywell sales office.
To assist in delivering the right products for our customers’ applications,
we listen to them to understand their needs. Using techniques such as
“Voice of the Customer” and “Concept Engineering,” we aim to deliver
the products and solutions. As part of Honeywell we can use local
knowledge and understanding combined with global expertise and
resources to achieve this. We can deploy many key technologies to bring
innovative solutions to customers’ problems.
There are, of course, many more product options available. Full product
specification information may be accessed on our web site
(www.honeywell.com/sensing). At the Home page enter the catalogue listing
reference in the SEARCH box and click GO! This will take you directly to the
interactive catalogue/specification search tables for this listing. Alternatively,
select and click the interactive catalogue icon on the Home page and then
choose a product category against which to do a specification search.
Also on the web site you can access installation instructions, application
notes, Frequently Asked Questions (FAQs), selection guides and
additional technical information.
Mounting dimensions
Mounting dimensions shown in each product section are for reference only.
For exacting layout work, request an engineering drawing from your nearest
Honeywell sales office. Where dual dimensions are shown on mounting
drawings, the first or upper one is millimetres (mm) and the second or lower
is inches (in). Where single dimensions are shown, they are millimetres
(mm), unless otherwise stated.
Our products are manufactured to work well and to last. We use Six
Sigma Plus productivity to ensure this is the case. We have award
winning manufacturing facilities around the world and recognised world
class business excellence in manufacturing and supply chain
management to deliver on time, anywhere in the world.
Our e-business approach offers instant access to product information,
technical support and application knowledge through our Internet site.
Check out our powerful new interactive catalogue that can search and
find the right products for customers’ needs and deliver a drawing ready
for incorporation in a CAD system direct to your desk.
And of course, we manage our whole business for the benefit of our
customers, using an acknowledged world-class business excellence approach
that incorporates Six Sigma principles.
To order these products
Simply contact your local Honeywell Distributor or your local Honeywell office.
More information on Honeywell products and how to contact us can be found
at http://locator.micro.honeywell.com/
© 2005 Honeywell International Inc. All rights reserved.
2
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
2
1/10/2006, 3:43 PM
CONTENTS
CONTENTS
Pressure Sensors
Page 4
Absolute, differential, gage and vacuum gage pressure sensors for
media that are compatible with a silicon diaphragm. These sensors are
often ideal for low-cost, commercial-grade applications such as printed
circuit boards. Small and reliable, they aim to offer excellent repeatability
and high accuracy under varying environmental conditions.
Mass Airflow Sensors
Page 13
Amplified and unamplified microbridge mass airflow sensors aim at
providing a sensitive, fast response and high accuracy over a broad
range of gas and air flows.
Force Sensors
Page 16
Compact, extremely sensitive devices for precise, reliable performance in
many applications that requires precision force measurement.
Humidity Sensors
Page 18
Relative humidity sensors with on-chip signal conditioning. Chemically
resistant packaging to accommodate many harsh environments. Sensor
construction consists of a planar capacitor with a second polymer layer
to protect against dirt, dust, oils and other hazards.
Temperature Sensors - RTDs
Page 19
Platinum and silicon-based thin film resistance temperature devices
(RTDs) for appropriate applications requiring small package size,
accuracy and linear outputs.
Temperature Sensors - Thermistors
Page 21
Precision Hi-Rel negative temperature coefficient (NTC) thermistors and
positive temperature coefficient (PTC) thermistors for use in a broad
variety of temperature measurement and control applications.
Temperature Sensors - Probes
Page 27
A variety of customized probes for use in the automotive and other
industries.
Thermal Cutoffs
Page 30
Dependable organic thermal cutoffs in temperatures ranging from 72 °C
to 240 °C [162 °F to 464 °F]. They are available in various lead lengths
and configurations.
Thermostats Redi-Temp ®
Page 32
Redi-Temp® is a line of standard thermostats offered in a range of preset temperatures. These standard products are available for immediate
delivery. They are often useful for low-volume applications where
standard configurations are acceptable.
! WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Thermostats - Commercial
Thermostats - Precision
3
Page 42
Hermetic and non-hermetic thermostats in standard and custom
packages for use in a wide variety of precision applications.
Thermostats - High Reliability
Page 63
Meet the stringent requirements of military and aerospace industries for
dielectric strength, moisture resistance, vibration, shock and hermetic
seal. These products meet all domestic and international approvals, as
well as appropriate military specifications.
Combi-sensor
Page 65
Liquid pressure/temperature sensor that uses piezoresistive and thermistor sensing technology to measure water pressure and temperature.
Heaters
Page 66
Wire-wound, chemically-etched, high temperature and transparent
heaters in a variety of sizes and geometries.
Magnetic Position Sensors
Page 68
Hall effect and magnetoresistive sensors for many applications that
require accurate, reliable outputs.
Infrared Products
Page 74
Optoelectronic standard infrared emitting diodes (IREDs), sensors and
assemblies for object presence, limit and motion sensing, position
encoding and movement encoding.
Current Sensors
Page 81
Adjustable linear null balance, digital and linear output current sensors
for monitoring ac or dc current.
Liquid Level Sensors
Page 87
Sensitive sensors in a variety of housing types for detecting the presence
or absence of a wide range of liquids.
Basic Switches
Page 89
Standard, miniature and subminiature switches available in a range of
enclosures and with a variety of actuators. They are often ideal for use
alone or built into assemblies.
Turbidity Sensors
Page 99
Turbidity sensing aims to provide a quick, practical indication of the
relative amount of solids suspended in water or liquids.
! WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices, or in any other application where failure of the
product could result in personal injury
Failure to comply with these instructions could result in
death or serious injury.
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
Page 34
Dependable bi-metal thermostats include a choice of automatic or
manual reset, phenolic or ceramic housings and a variety of mounting
brackets and terminal options.
1/10/2006, 3:43 PM
3
PRESSURE
Honeywell pressure sensors are small, low cost and reliable. They
promote excellent repeatability, high accuracy and reliability under
varying environmental conditions. In addition, they feature highly
consistent operating characteristics from one sensor to the next and
interchangeability without recalibration.
Pressure Sensors
We offer three pressure sensor measurement types—absolute,
differential and gage—including vacuum gage and bidirectional types. A
wide variety of pressure ranges, along with both amplified and
unamplified versions, are available.
Honeywell pressure sensors are best used in applications which require
precision pressure measurement.
24PC/26PC Series
24PC Series
Signal conditioning:
MEASUREMENT TYPE
Gage/vacuum gage
Differential/vacuum gage
Gage/vacuum gage
Differential/vacuum gage
Gage/vacuum gage
Differential/vacuum gage
Gage/vacuum gage
Differential
Gage
Differential
Gage
Supply voltage:
Operating temperature:
Port style:
Termination:
Unamplified noncompensated (24PC Series)
Compensated (26PC Series)
10 Vdc typ.
12 Vdc max. (24PC Series)
16 Vdc max. (26PC Series)
-40 °C to 85 °C [-40 °F to 185 °F]
Straight or flow through
PCB; 1 x 4; 0.600 in (Type 6)
PCB; 2 x 2; (Type 2)
1 x 4 with connector (Type 5)
PRESSURE RANGE
1.0 psi
5.0 psi
5.0 psi
15.0 psi
15.0 psi
30.0 psi
30.0 psi
0.5 psi
0.5 psi
100 psi
100 psi
REFERENCE
24PCAFA6G
24PCBFA6D
24PCBFA6G
24PCCFA6D
24PCCFA6G
24PCDFA6D
24PCDFA6G
24PCEFA6D
24PCEFA6G
24PCFFA6D
24PCFFA6G
PRESSURE RANGE
1.0 psi
1.0 psi
5.0 psi
5.0 psi
15.0 psi
15.0 psi
30.0 psi
30.0 psi
100 psi
250 psi
REFERENCE
26PCAFA6D
26PCAFA6G
26PCBFA6D
26PCBFA6G
26PCCFA6D
26PCCFA6G
26PCDFA6D
26PCDFA6G
26PCFFA6G
26PCGFA6D
PRESSURE RANGE
15.0 psi
30.0 psi
REFERENCE
24PCCFG6G
24PCDFG6G
PRESSURE RANGE
1.0 psi
15.0 psi
100 psi
REFERENCE
26PCAFG6G
26PCCFG6G
26PCFFG6G
26PC Series
OPTIONS
MEASUREMENT TYPE
Differential/vacuum gage
Gage/vacuum gage
Differential
Gage
Differential/vacuum gage
Gage/vacuum gage
Differential
Gage
Gage
Differential
Differential
Flow through
Type 6
Gage
MOUNTING DIMENSIONS (for reference only) mm/in
GAUGE SENSOR
1 x 4 Termination (Style 6) Port Style A, Straight
Pin 1 is notched, Pin 2 is next to Pin 1, etc.
24PC Series
MEASUREMENT TYPE
Flow through/vacuum gage
Flow through/vacuum gage
26PC Series
MEASUREMENT TYPE
Flow through/vacuum gage
Flow through
Gage/vacuum gage
4
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
4
1/10/2006, 3:43 PM
PRESSURE
24PC/26PC Series (continued)
Type 2
OPTIONS
26PC Series
MEASUREMENT TYPE
Flow through
PRESSURE RANGE
30.0 psi
REFERENCE
26PCDFG2G
Type 5
24PC SMT Series
PRESSURE RANGE
0 psi to 1.0 psi
0 psi to 5.0 psi
0 psi to 15.0 psi
REFERENCE
24PC01SMT
24PC05SMT
24PC15SMT
26PC SMT Series
PRESSURE RANGE
0 psi to 1.0 psi
0 psi to 5.0 psi
0 psi to 15.0 psi
REFERENCE
26PC01SMT
26PC05SMT
26PC15SMT
CPC/CPX Series, Low Pressure
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Accuracy grade:
26PC Series
MEASUREMENT TYPE
Flow through/vacuum gage
PRESSURE RANGE
100 psi
Unamplified
Compensated (CPC Series)
Noncompensated (CPX Series)
12 Vdc typ., 16 Vdc max.
-25 °C to 85 °C [-13 °F to 185 °F]
Barbed
PCB
Commercial (1.0 %)
REFERENCE
26PCFFU5G
24PC/26PC SMT (Surface-Mount
Technology)
Signal conditioning:
Unamplified noncompensated (24PC SMT Series)
Compensated (26PC SMT Series)
Supply voltage:
10 Vdc typ.
12 Vdc max. (24PC SMT Series)
16 Vdc max. (26PC SMT Series)
Operating temperature:
-40 °C to 85 °C [-40 °F to 185 °F]
Port style:
Straight, Ø 1,88 mm [0.74 in]
Termination:
SMT solder
Measurement type: Gage, vacuum gage, differential, wet/wet differential
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
5
1/10/2006, 3:43 PM
5
PRESSURE
CPC/CPX Series, Low Pressure (continued) DCXL/DUXL Series, Low Pressure
Signal conditioning:
Unamplified
Compensated (DCXL)
Noncompensated (DUXL)
12 Vdc typ., 16 Vdc max. (DCXL)
4.5 Vdc min., 8 Vdc max. (DUXL)
-25 °C to 85 °C [-13 °F to 185 °F]
Barbed
PCB
OPTIONS
Supply voltage:
CPC Series
MEASUREMENT TYPE
Differential
Gage
Differential
PRESSURE RANGE
1.0 psi [4.0 in H2O]
1.0 psi [4.0 in H2O]
1.0 psi [10.0 in H2O]
REFERENCE
CPCL04DFC
CPCL04GFC
CPCL10DFC
PRESSURE RANGE
4.0 in H2O
10.0 in H2O
REFERENCE
CPXL04DF
CPCL10DF
OPTIONS
CPX Series
MEASUREMENT TYPE
Differential
Differential
Operating temperature:
Port style:
Termination:
DC Series, Low Pressure
Signal conditioning:
Amplified compensated
Unregulated (DC001NDC4)
Regulated (DC005NDR4)
5 Vdc typ., 5.1 Vdc max. (DC001NDC4)
7 Vdc to 35 Vdc (DC005NDR4)
-25 °C to 85 °C [-13 °F to 185 °F]
Barbed
PCB
Supply voltage:
Operating temperature:
Port style:
Termination:
OPTIONS
DCXL Series
MEASUREMENT TYPE
Differential
Differential
PRESSURE RANGE
1.0 in H2O
10.0 in H2O
REFERENCE
DCXL01DN
DCXL10DN
PRESSURE RANGE
1.0 in H2O
10.0 in H2O
REFERENCE
DUXL01D
DUXL10D
DC001NDC4
MEASUREMENT TYPE
Differential
PRESSURE RANGE
1.0 in H2O
REFERENCE
DC001NDC4
PRESSURE RANGE
5.0 in H2O
REFERENCE
DC005NDR4
DC005NDR4
MEASUREMENT TYPE
Differential
DUXL Series
6
Glo_Comm_minicat_Iss3_FINAL .PMD
MEASUREMENT TYPE
Differential
Differential
www.honeywell.com/sensing
6
1/10/2006, 3:43 PM
PRESSURE
XCA Series
XPC Series
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Amplified compensated
5 Vdc typ., 16 Vdc max.
-25 °C to 85 °C [-13 °F to 185 °F]
Barbed
PCB
MEASUREMENT TYPE
Absolute
PRESSURE RANGE
15.0 psia
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Accuracy grade:
Unamplified compensated
12 Vdc typ., 16 Vdc max.
-25 °C to 85 °C [-13 °F to 185 °F]
Barbed
PCB
Commercial (1.0 %)
REFERENCE
XCA415AN
XCX Series
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Accuracy grade:
Unamplified compensated
12 Vdc typ., 16 Vdc max.
-25 °C to 85 °C [-13 °F to 185 °F]
Barbed
PCB
Commercial (1.0 %)
MEASUREMENT TYPE PRESSURE RANGE
Differential
1.0 psi
Differential
15.0 psi
PORT STYLE
Axial
Radial
REFERENCE
XPC01DFC
XPC15DTC
XSX Series, Low Pressure
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Accuracy grade:
MEASUREMENT TYPE
Differential
Differential
Differential
PRESSURE RANGE
1.0 psi
1.0 psi
15.0 psi
ACCURACY GRADE
High (0.50 %)
REFERENCE
XCX01DNC
XCX01DNH
XCX15DNC
MEASUREMENT TYPE
Gage
PRESSURE RANGE
4.0 in H2O
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
7
Unamplified uncompensated
12 Vdc typ., 16 Vdc max.
-25 °C to 85 °C [-13 °F to 185 °F]
Button
PCB
Commercial (1.0 %)
1/10/2006, 3:43 PM
REFERENCE
XSXL04GF
7
PRESSURE
ASDX Series
ASDX DO (Digital Output) Series
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Accuracy grade:
Amplified compensated
4.75 Vdc to 5.25 Vdc
-20 °C to 105 °C [-4 °F to 221 °F]
Taper 2,29 mm [0.090 in]
PCB
±2.0 %
A2 package
MEASUREMENT TYPE
Absolute
Absolute
Absolute
PRESSURE RANGE
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
REFERENCE
ASDX015A24R
ASDX030A24R
ASDX100A24R
MEASUREMENT TYPE
Absolute
Absolute
Absolute
PRESSURE RANGE
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
REFERENCE
ASDX015A24R-DO
ASDX030A24R-DO
ASDX100A24R-DO
PRESSURE RANGE
0 psi to 1 psi
0 psi to 1 psi
0 psi to 5 psi
0 psi to 5 psi
0 psi to 15 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 30 psi
0 psi to 100 psi
REFERENCE
ASDX001D44R-DO
ASDX001D44D-DO
ASDX005D44R-DO
ASDX005D44D-DO
ASDX015D44R-DO
ASDX015D44D-DO
ASDX030D44R-DO
ASDX030D44D-DO
ASDX100D44R-DO
PRESSURE RANGE
0 psi to 1 psi
0 psi to 5 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
REFERENCE
ASDX001G24R-DO
ASDX005G24R-DO
ASDX015G24R-DO
ASDX030G24R-DO
ASDX100G24R-DO
D4 package
MEASUREMENT TYPE
Differential/gage
Differential/gage
Differential/gage
Differential/gage
Differential/gage
PRESSURE RANGE
0 psi to 1 psi
0 psi to 5 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
REFERENCE
ASDX001D44R
ASDX005D44R
ASDX015D44R
ASDX030D44R
ASDX100D44R
G2 package
MEASUREMENT TYPE
Differential/gage
Differential/gage
Differential/gage
Differential/gage
Differential/gage
Differential/gage
Differential/gage
Differential/gage
Differential/gage
G2 package
PRESSURE RANGE
0 psi to 1 psi
0 psi to 5 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
8
Glo_Comm_minicat_Iss3_FINAL .PMD
Amplified
4.75 Vdc to 5.25 Vdc
-20 °C to 105 °C [-4 °F to 221 °F]
Taper 2,29 mm [0.090 in]
PCB
±2.0 %
A2 package
D4 package
MEASUREMENT TYPE
Gage
Gage
Gage
Gage
Gage
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Accuracy grade:
REFERENCE
ASDX001G24R
ASDX005G24R
ASDX015G24R
ASDX030G24R
ASDX100G24R
MEASUREMENT TYPE
Gage
Gage
Gage
Gage
Gage
www.honeywell.com/sensing
8
1/10/2006, 3:43 PM
PRESSURE
ASDXL Series
ASDXL DO (Digital Output) Series
Signal conditioning:
Output signal:
Operating temperature:
Port style:
Termination:
Accuracy grade:
Amplified
0.5 Vdc to 4.5 Vdc
Compensated 0 °C to 85 °C [32 °F to 185 °F]
Taper 2,29 mm [0.090 in]
PCB
2.0 %
Signal conditioning:
Output signal:
Operating temperature:
Port style:
Termination:
Accuracy grade:
Amplified
HEX E25 to EA8
Compensated 0 °C to 85 °C [32 °F to 185 °F]
Taper 2,29 mm [0.090 in]
PCB
2.0 %
D4 package
D4 package
MEASUREMENT TYPE
Bidirectional
Bidirectional
Differential
PRESSURE RANGE
±5 in H20
0 in to 10 in H2O
0 in to 10 in H2O
REFERENCE
ASDXL005D44D
ASDXL010D44D
ASDXL010D44R
MEASUREMENT TYPE
Bidirectional
Bidirectional
Differential
REFERENCE
ASDXL005D44D-DO
ASDXL010D44D-DO
ASDXL010D44R-DO
PRESSURE RANGE
0 in to 10 in H2O
REFERENCE
ASDXL010G25R-DO
G2 package
G2 package
MEASUREMENT TYPE
Gage
PRESSURE RANGE
0 in to 10 in H2O
REFERENCE
ASDXL010G24R
MEASUREMENT TYPE
Gage
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
PRESSURE RANGE
±5 in H2O
±10 in H2O
0 in to 10 in H2O
9
1/10/2006, 3:43 PM
9
PRESSURE
140PC Series
SDX Series
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Amplified
8 Vdc typ., 16 Vdc max.
-40 °C to 85 °C [-40 °F to 185 °F]
Straight
PCB
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Calibrated zero and span
20 Vdc
Calibrated 0 °C to 50 °C [32 °F to 122 °F]
Straight
PCB
Note: Dimensions shown apply to Differential and Absolute versions.
Gage units are identical, except the P1 port is absent.
MEASUREMENT TYPE
Gage/vacuum gage
Differential/vacuum gage
Gage
Gage
Differential/vacuum gage
Differential/vacuum gage
Gage
Absolute
Absolute
Gage
Differential/vacuum gage
Differential/vacuum gage
PRESSURE RANGE
TERMINATION
15 psi
1.0 psi
1.0 psi
2.0 psi
5.0 psi
-39 in H2O to 55 in H2O
5.0 psi
15 psia
15 psia
Leadwire
15 psi
±2.5 psi
±5.0 psi
Leadwire
REFERENCE
141PC15G
142PC01D
142PC01G
142PC02G
142PC05D
142PC05D97
142PC05G
142PC15A
142PC15AW95
142PC15G
143PC03D
143PC05DW
A2/G2 package
MEASUREMENT TYPE
Gage
Absolute
PRESSURE RANGE
0 psi to 5 psi
0 psi to 15 psi
REFERENCE
SDX05G2
SDX15A2
PRESSURE RANGE
0 psi to 1 psi
0 psi to 5 psi
0 psi to 15 psi
REFERENCE
SDX01D4
SDX05D4
SDX15D4-A
160PC Series, Low Pressure
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Amplified
8 Vdc typ., 16 Vdc max.
-40 °C to 85 °C [-40 °F to 185 °F]
Straight
PCB
D4 package
MEASUREMENT TYPE
Differential
Differential
Differential
Note: Dimensions shown apply to Differential and Absolute versions.
Gage units are identical, except the P1 port is absent.
MEASUREMENT TYPE
Differential/vacuum gage
Differential/vacuum gage
Differential/vacuum gage
Differential/vacuum gage
Differential/vacuum gage
Differential/vacuum gage
Differential/vacuum gage
PRESSURE RANGE
0 in to 27.68 in H2O
±5.0 in H2O
-20 cm to 120 cm H2O
-20 cm to 120 cm H2O
±2.5 in H2O
10.0 in H2O
5.0 in H2O
10
Glo_Comm_minicat_Iss3_FINAL .PMD
SUPPLY VOLTAGE
5 Vdc
REFERENCE
162PC01D
163PC01D36
163PC01D48
163PC01D61
163PC01D75
164PC01D37
164PC01D76
www.honeywell.com/sensing
10
1/10/2006, 3:43 PM
PRESSURE
SDX IND Series
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
HPX Series
Calibrated zero and span
20 Vdc
Calibrated 0 °C to 50 °C [32 °F to 122 °F]
Straight
PCB
Signal conditioning:
Supply voltage:
Operating temperature:
Termination:
None
3 Vdc typ., 10 Vdc max.
-20 °C to 100 °C [-4 °F to 212 °F]
PCB
SOIC package
MEASUREMENT TYPE
Differential
Differential
PRESSURE RANGE
0 in H2O to 5 in H2O
0 in H2O to 10 in H2O
REFERENCE
SDX005IND4
SDX010IND4
MEASUREMENT TYPE
Absolute
Absolute
Absolute
Absolute
PRESSURE RANGE
0 psi to 15 psi
0 psi to 30 psi
0 psi to 50 psi
0 psi to 100 psi
REFERENCE
HPX015AS
HPX030AS
HPX050AS
HPX100AS
40PC Series, Miniature Signal
Conditioned
Signal conditioning:
Supply voltage:
Operating temperature:
Port style:
Termination:
Amplified
5 Vdc ±0.25 Vdc
-45 °C to 125 °C [-49 °F to 257 °F]
Straight for O-ring interface
PCB, unformed
DIP package
MEASUREMENT TYPE
Bi-directional gage/vacuum gage
Gage
Vacuum
Gage
Gage
Gage
Gage
Gage
Gage
PRESSURE RANGE
±50 mm Hg
0 to 300 mm HG
0 to -15.0 psi
15.0 psi
30.0 psi
100 psi
150 psi
250 psi
500 psi
REFERENCE
40PC001B1A
40PC006G1A
40PC015V1A
40PC015G1A
40PC030G1A
40PC100G1A
40PC150G1A
40PC250G1A
40PC500G1A
MEASUREMENT TYPE
Gage
Gage
Gage
Gage
Gage
PRESSURE RANGE
0 psi to 5.8 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 50 psi
0 psi to 100 psi
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
11
1/10/2006, 3:43 PM
REFERENCE
HPX005GD
HPX015GD
HPX030GD
HPX050GD
HPX100GD
11
PRESSURE
HSD Series
Signal conditioning:
Supply voltage:
Operating temperature:
Output signal:
Termination:
MEASUREMENT TYPE
Absolute
Amplified
3.0 Vdc ±0.01 Vdc
-20 °C to 105 °C [-4 °F to 221 °F]
HEX E25 to EA8
OCLPP (Open Cavity Leadless Plastic Package)
PRESSURE RANGE
0 psi to 15 psi
12
Glo_Comm_minicat_Iss3_FINAL .PMD
REFERENCE
HSD015A
www.honeywell.com/sensing
12
1/10/2006, 3:43 PM
MASS AIRFLOW
Mass Airflow sensors contain a thin-film, thermally isolated bridge
structure that consists of a heater and temperature sensing elements.
The bridge structure promotes sensitivity and fast response to the flow
of air or other gas over the chip.
Mass Airflow Sensors
State-of-the-art chip design and manufacturing techniques allow the
microbridge to be sensitive, fast and small. Used in appropriate
applications where airflow needs to be measured.
Supply voltage:
Operating temperature:
Media compatibility:
8 Vdc to 15 Vdc
-25 °C to 85 °C [-13 °F to 185 °F]
Dry gas only
AWM2000 Series
AWM3000 Series
The AWM2000 Series microbridge mass airflow sensor is a passive
device comprised of two Wheatstone bridges and has bidirectional
sensing capability. The heater control circuit is required for operation per
specifications. The sensing bridge supply circuit is also required for
operation per specifications. These two circuits are not on board the
package and must be supplied in the application. The differential amplifier
is often a useful interface for the sensing bridge. It can be used to
introduce gain and to voltage offsets to the sensor output.
Like the AWM2000 Series, the dual Wheatstone bridges control airflow
measurement. The AWM3000 Series is amplified; therefore, it can be
used to increase the gain and to introduce voltage offsets to the sensor
output. The heater control circuit and the sensing bridge supply circuit
are on board the package.
Signal conditioning:
Port style:
Sensor resistance:
Signal conditioning:
Port style:
Unamplified (-44.5 mVdc to 44.5 mVdc)
Straight
5 kOhm
FLOW/PRESSURE RANGE
±200 sccm
±4.0 in H2O (10 mBar)
±1000 sccm (1 SLPM)
REFERENCE
AWM2100V
AWM2200V
AWM2300V
FLOW/PRESSURE RANGE
±200 cm
+2.0 in H20 (5 mBar)
±1000 sccm (1 SLPM)
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
Amplified (1 Vdc to 5 Vdc)
Straight
13
1/10/2006, 3:43 PM
REFERENCE
AWM3100V
AWM3200V
AWM3300V
13
MASS AIRFLOW
AWM40000 Series
AWM5000 Series - High Flow
The microbridge mass airflow sensor operates on the theory of heat
transfer. Mass airflow is directed across the surface of the sensing
elements. Output voltage varies in proportion to the mass air or other
gas flow through the inlet and outlet ports of the package. The specially
designed housing precisely directs and controls the airflow across the
microstructure sensing element. Mechanical design of the package
typically allows it to be easily mounted to printed circuit boards.
AWM5000 Series microbridge mass airflow sensors feature a venturi
type flow housing. They measure flow as high as 20 standard liters per
minute (SLPM) while inducing a maximum pressure drop of 2.25 in H2O.
The microbridge chip is in direct contact with the flow stream, greatly
reducing error possibilities due to orifice or bypass channel clogging.
The microbridge mass airflow sensor has a unique silicon chip based on
advanced microstructure technology. It consists of a thin-film, thermally
isolated bridge structure containing heater and temperature sensing
elements. The bridge structure provides a sensitive and fast response to
the flow of air or other gas over the chip. Dual sensing elements
positioned on both sides of a central heating element indicate flow
direction as well as flow rate. Laser trimmed thick film and thin film
resistors provide consistent interchangeability from one device to the
next.
Port style:
SIGNAL CONDITIONING
Unamplified (8.5 mV)
Unamplified (54.7 mV)
Amplified (1 Vdc to 5 Vdc)
Amplified (1 Vdc to 5 Vdc)
Manifold
FLOW/PRESSURE RANGE
±25 sccm
±1000 sccm (1 SLPM)
±1000 sccm (1 SLPM)
+ 6 SLPM
REFERENCE
AWM42150VH
AWM42300V
AWM43300V
AWM43600V
The rugged plastic package has been designed to withstand common
mode pressures up to 50 psi, and the small sensing element allows
100 g of shock without compromising performance. The included
“AMP” compatible connector provides reliable connection in many
demanding applications.
Each AWM5000 sensor contains circuitry which performs amplification,
linearization, temperature compensation and gas calibration. A 1 Vdc to
5 Vdc linear output is possible for all listings regardless of flow range
(5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide,
nitrous oxide or argon). All calibration is performed by active laser.
Signal conditioning:
Port style:
Amplified (1 Vdc to 5 Vdc)
Threaded, ¼ in NPT
FLOW/PRESSURE RANGE
0 SLPM to 5 SLPM (N2 calibration)
0 SLPM TO 10 SLPM (N2 calibration)
0 SLPM to 20 SLPM (CO2 calibration)
0 SLPM to 20 SLPM (N2 calibration)
REFERENCE
AWM5101VN
AWM5102VN
AWM5104VC
AWM5104VN
CAUTION
PRODUCT DAMAGE
AWM Series Microbridge Mass Airflow Sensors are not
designed to sense liquid flow and will be damaged by
liquid flow through the sensor.
Failure to comply with these instructions could result in
product damage.
14
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
14
1/10/2006, 3:44 PM
FORCE
MASS AIRFLOW
AWM700 Series
NOTICE
AWM700 Series microbridge mass airflow sensors provide in-line flow
measurement with a specially designed bypass flow housing. The
sensors measure flow as high as 200 standard litres per minute (SLPM)
while inducing a pressure drop of 1 inch H2O, typically. The AWM700 has
a high flow range capability in a small package.
Signal conditioning:
Port style:
Amplified (1 Vdc to 5 Vdc)
Tapered, 22 mm
FLOW/PRESSURE RANGE
+ 200 SLPM
REFERENCE
AWM720P1
LAMINAR FLOW
Due to the fast response time of the sensor, these
specifications were generated using laminar flow.
Airflow instability or “turbulence” present in the
airstream will result in an increase in measurement
uncertainty.
The turbulent flow problem can be corrected by either
straightening the airflow using flow laminarizing or by
slowing the response of the sensor using a simple RC
time constant on the output of the sensor. This, of
course, slows down the sensor response time. The
values needed depend on the amount of turbulence
present in the application.
Several techniques for laminarizing the flow include
adding hex shaped honeycombs, foam, screen
materials or adding constrictors (frits) to the flow
stream. There are various commercial laminar flow
elements that can be purchased. Unfortunately the
greater the efficiency of the laminarizer, the greater the
increase in pressure drop in order to establish a given
flow rate. Plastic honeycomb material probably gives
the most improvement for the least pressure drop. In
any test fixture, the avoidance of sharp radii is an
absolute requirement.
CAUTION
AWM90000 Series
PRODUCT DAMAGE
The AWM90000 Series microbridge mass airflow sensors are available in
two versions, mass flow and differential pressure. The AWM92100V has
a flow range of ±200 sccm with a pressure drop of only 0.49 mBar,
typically. The AWM92200V is a differential pressure version that has a
range of ±2 in H2O.
The AWM90000 Series has a 1 ms response time, operates with a
supply voltage from 8.0 Vdc to 15.0 Vdc, while consuming only 50 mW
of power. The compact plastic package will withstand a maximum
overpressure of 25 psi without compromising performance.
Signal Conditioning:
Port Style:
AWM Series Microbridge Mass Airflow Sensors are not
designed to sense liquid flow and will be damaged by liquid
flow through the sensor.
Failure to comply with these instructions could result in
product
Unamplified
Straight
FLOW RANGE (FULL SCALE)
±200 SCCM
PRESSURE RANGE
±2.0 H2O (5 mBar)
REFERENCE
AWM92100V
AWM92200V
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
15
1/10/2006, 3:44 PM
15
FORCE
Force Sensors
Force sensors operate on the principle that the resistance of siliconimplanted piezoresistors will increase when the resistors flex under any
applied force. The sensor concentrates force from the application,
through the stainless steel plunger, directly to the silicon sensing
element. The amount of resistance changes in proportion to the amount
of force being applied. This change in circuit resistance results in a
corresponding mV output level.
FSG Series
FSL Series
Supply voltage:
360 mV span @ 10 Vdc
Operating temperature:
-40 °C to 85 °C [-40 °F to 185 °F]
Sensitivity:
0.20 mV/g min., 0.24 mV/g typ., 0.28 mV/g max.
Overforce:
5500 g
Supply voltage:
60 mV span @ 5 Vdc
Operating temperature:
-40 °C to 85 °C [-40 °F to 185 °F]
Sensitivity:
0.10 mV/g min., 0.12 mV/g typ., 0.14 mV/g max.
Overforce:
4500 g
Plunger actuator - force range 1500 g
Ball bearing actuator - force range 500 g
REFERENCE
FSG15N1A
Non-compensated
16
Glo_Comm_minicat_Iss3_FINAL .PMD
REFERENCE
FSG15N1A
Non-compensated
www.honeywell.com/sensing
16
1/10/2006, 3:44 PM
FORCE
FORCE
Model 1865 Force/Pressure Transducer
FS Series Force/Pressure Sensor
Model 1865 is a high-performance transducer specifically designed to
address the needs of certain medical and specialized OEM applications.
Offering laser-trimmed compensation, Model 1865 may be specified to
operate with either a constant current or voltage supply.
The FS01/FS03 Sensors are special low-cost, peizoresistive-based
force sensors. These high-level voltage output, calibrated and
temperature- compensated sensors give an accurate and stable
output over a 5 °C to 50 °C [41 °F to 122 °F] temperature range.
They offer simple operation from a single 5.0 Vdc supply. The FS01/
FS03 sensors feature an integrated circuit sensor element and lasertrimmed, thick-film ceramic in a small plastic housing. Their extremely
small size often enables the use of multiple sensors in limited available
space. This package also provides excellent corrosion resistance and
isolation to external package stress.
Model 1865 employs a solid state piezoresistive pressure transducer
mounted in a plastic package. For applications where force is applied by
a flexible membrane to the sensor, such as found in infusion pumps,
Model 1865’s precision height silicone diaphragm provides long life and
is often a reliable replacement for older force or load cell transducers.
Utilizing a silicon rubber diaphragm, Model 1865 is compatible with
some liquid media applications. Model 1865 may be operated in either
current or voltage excitation, and its output may be amplified or signal
conditioned, as required. The semiconductor-based sensor offers high
resolution using its Wheatstone bridge strain gage design. The height of
the unit’s patented, poured-in-place silicon rubber diaphragm is
controlled to promote sensitivity to low pressure. This diaphragm is
bonded to a plastic header and transmits force applied through a special
silicone gel to the diaphragm of a silicon piezoresistive die. The back of
the die is exposed to atmospheric pressure, which results in a gage
pressure output.
Supply voltage:
Operating temperature:
Maximum force:
12.0 Vdc
0 °C to 70 °C [32 °F to 158 °F]
7 lb
Pressure over-range protection: 3X span or 60 psi, whichever is least
Media/materials compatibility
Top side:
Room atmosphere, directly applied force, and liquids
compatible with dimethyl silicon, polyetherimide (Ultem®)
Bottom side:
Non-corrosive dry gasses and fluids compatible with
silicon, pyrex, RTV silicone and ceramic
Sensor:
Gage pressure
Diaphragm:
Dimethyl silicone
Compensation:
Laser-trimmed normalized output
PRESSURE
0 lb to 1.5 lb
0 lb to 3.0 lb
REFERENCE
FS01
FS03
OPTIONS
Excitation 1.5 mA
PRESSURE
0 psi to 5 psi
0 psi to 10 psi
0 psi to 15 psi
0 psi to 25 psi
0 psi to 30 psi
REFERENCE
1865-01G-L-N
1865-02G-L-N
1865-03G-L-N
1865-04G-L-N
1865-05G-L-N
Excitation 10 Vdc
PRESSURE
0 psi to 5 psi
0 psi to 10 psi
0 psi to 15 psi
0 psi to 25 psi
0 psi to 30 psi
REFERENCE
1865-01G-K-N
1865-02G-K-N
1865-03G-K-N
1865-04G-K-N
1865-05G-K-N
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
17
1/10/2006, 3:44 PM
17
HUMIDITY
Relative Humidity/Temperature and Relative Humidity sensors are
configured with integrated circuitry to provide on-chip signal
conditioning. These sensors contain a capacitive sensing die set in
thermoset polymers that interacts with platinum electrodes. The laser
trimmed sensors have an interchangeability of ±5 % from 0 %RH to
60 %RH, with stable, low drift performance.
Humidity Sensors
Absorption based humidity sensors provide both temperature and %RH
(Relative Humidity) outputs. On-chip signal processing ensures linear
voltage output versus %RH. Sensor laser trimming offers accuracy of
± 2.5 %, and achieves 2 %RH accuracy with calibration.
Supply voltage:
Operating humidity range:
Operating temperature range:
4.0 Vdc to 5.8 Vdc
0 %RH to 100 %RH, non-condensing
-40 °C to 85 °C [-40 °F to 185 °F]
HIH-4000 Series
HIH Series
The HIH-4000 Series humidity sensors are designed specifically for high
volume OEM users. Direct input to a controller or other device is made
possible by this sensor’s linear voltage output. With a typical current
draw of only 200 µA, the HIH-4000 Series is often ideally suited for low
drain, battery operated systems. Tight sensor interchangeability reduces
or eliminates OEM production calibration costs. Individual sensor
calibration data is available.
HIH-3602 Monolithic integrated circuit
These sensors deliver instrumentation-quality RH sensing performance
in a competitively priced, solderable SIP. Available in two lead spacing
configurations, the RH sensor is a laser trimmed, thermoset polymer
capacitive sensing element with on-chip integrated signal conditioning.
Package style:
HIH-3602-A and HIH-3602-C RH sensors combine both relative
humidity and temperature sensing in a TO-5 housing with a hydrophobic
sintered stainless steel filter. The temperature sensor is thermally
connected with the RH sensor making the HIH-3602-A/C often ideal for
measuring dew point and other absolute moisture terms.
Package style:
Termination:
NIST certification:
TO-5 can
0,46 mm [0.18 in]
NIST calibration sensor-specific printout
Solderable SIP
TEMPERATURE SENSOR
100 kOhm ±5 % @ 25 °C, NTC 0-50 C
1000 Ohm ±0.2 % @ 0 °C, platinum RTD
REFERENCE
HIH-3602-A
HIH-3602-C
HIH-3602-L Integrated circuit
TERMINATION
2,54 mm [0.100
1,27 mm [0.050
2,54 mm [0.100
1,27 mm [0.050
in]
in]
in]
in]
lead
lead
lead
lead
pitch
pitch
pitch
pitch
CALIBRATION
None
None
with calibration and data printout
with calibration and data printout
REFERENCE
HIH-4000-001
HIH-4000-002
HIH-4000-003
HIH-4000-004
The HIH-3602-L Relative Humidity (RH) sensor delivers instrumentationquality RH sensing performance in a rugged, low cost, slotted TO-39
housing. On-board signal conditioning reduces product development
times while a typical current draw of only 200 µA makes the HIH-3602-L
perfect for battery powered systems. This sensor should be shielded
from bright light.
Package style:
Termination:
NIST certification:
T0-39 can
0,46 mm [0.18 in]
None
CAUTION
PRODUCT DAMAGE
The inherent design of this component causes it to be
sensitive to the electrostatic discharge (ESD). To prevent
ESD-induced damage and/or degradation, take normal ESD
precautions when handling this product.
Failure to comply with these instructions could result in
product damage
18
Glo_Comm_minicat_Iss3_FINAL .PMD
REFERENCE
HIH-3602-L
www.honeywell.com/sensing
18
1/10/2006, 3:44 PM
TEMPERATURE - RTDS
Temperature Sensors - RTDs
Honeywell’s thin-film RTD (Resistance Temperature Detector) temperature
sensors feature two distinct series. These sensors are laser-trimmed for
accuracy and interchangeability. Linear outputs are stable and fast.
The TD Series Temperature Sensors are silicon-based RTDs. They offer
2000 Ohm nominal resistance at 20 °C. Temperature range of -40 °C to
150 °C [-40 °F to 302 °F].
The HEL Series Temperature Sensors are platinum RTDs, offering
100 Ohm or 1000 Ohm versions and temperature ranges of -200 °C to
540 °C [-300 °F to 1000 °F].
HEL-700 Series 100/1000 Ohm Platinum
RTD
Supply voltage:
Base resistance
and interchangeability:
4 Vdc to 9 Vdc
1000 ±2 Ohm (±0.2 %) @ 0 °C (standard)
1000 ±1 Ohm (±0.1 %) @ 0 °C (optional)
OPTIONS
HEL-700
Temperature range:
Packaging style/termination:
Type A
-200 °C to 540 °C [-300 °F to 1000 °F]
Radial chip/ribbon leads (type A)
Radial chip/no leads (type B)
SMT (axial) flip chip/no leads (type C)
100 Ohm
(0.00385 Ohm/Ohm/°C DIN standard)
PACKAGING STYLE
Type A
Type A
BASE RESISTANCE AND INTERCHANGEABILITY
Standard
Optional
REFERENCE
HEL-700-T-0-A
HEL-700-T-1-A
Type B
Type B
Standard
Optional
HEL-700-T-0-B
HEL-700-T-1-B
1000 Ohm
(0.00375 Ohm/Ohm/°C)
PACKAGING STYLE
Type A
Type A
BASE RESISTANCE AND INTERCHANGEABILITY
Standard
Optional
REFERENCE
HEL-700-U-0-A
HEL-700-U-1-A
Type B
Type B
Standard
Optional
HEL-700-U-0-B
HEL-700-U-1-B
Type C
Type C
Standard
Optional
HEL-700-U-0-C
HEL-700-U-1-C
Type B
Type C
Centre lead
not connected
CAUTION
PRODUCT DAMAGE
The inherent design of this component causes it to be
sensitive to the electrostatic discharge (ESD). To prevent
ESD-induced damage and/or degradation, take normal ESD
precautions when handling this product.
Failure to comply with these instructions could result in
product damage
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
19
1/10/2006, 3:44 PM
19
TEMPERATURE - RTDS
HEL-700 Series 100/1000 Ohm Platinum
RTD (continued)
TD Series 2000 Ohm Silicon RTD
HEL-705/707/711/712/716/717
OPTIONS
Temperature range:
-200 °C to 260 °C [-320 °F to 500 °F]
(HEL-705/711/716)
-75 °C to 540 °C [-100 °F to 1000 °F]
(HEL-707/712/717)
Ceramic case
12 in leadwires
None
Packaging style:
Termination:
NIST calibration:
Supply voltage:
Temperature range:
10 Vdc
-40 °C to 150 °C [-40 °F to 302 °F]
TD4A Liquid temperature sensor
PACKAGING STYLE
Threaded aluminium case
TERMINATION
Leadwires
REFERENCE
TD4A
100 Ohm
(0.00385 Ohm/Ohm/°C DIN standard)
BASE RESISTANCE AND INTERCHANGEABILITY
Standard
Optional
REFERENCE
HEL-705-T-0-12-00
HEL-705-T-1-12-00
Standard
Optional
HEL-707-T-0-12-00
HEL-707-T-1-12-00
Standard
Optional
HEL-711-T-0-12-00
HEL-711-T-1-12-00
Standard
Optional
HEL-712-T-0-12-00
HEL-712-T-1-12-00
Standard
Optional
HEL-716-T-0-12-00
HEL-716-T-1-12-00
Standard
Optional
HEL-717-T-0-12-00
HEL-717-T-1-12-00
TD5A Subminiature temperature sensor
PACKAGING STYLE
Plastic case
TERMINATION
SIP
1000 Ohm
(0.00375 Ohm/Ohm/°C)
BASE RESISTANCE
AND INTERCHANGEABILITY
Standard
Optional
NIST CALIBRATION
REFERENCE
HEL-705-U-0-12-00
HEL-705-U-1-12-00
Standard
Optional
HEL-707-U-0-12-00
HEL-707-U-1-12-00
Standard
Optional
HEL-711-U-0-12-00
HEL-711-U-1-12-00
Standard
Optional
HEL-712-U-0-12-00
HEL-712-U-1-12-00
Standard
Optional
Optional
NIST @ 0 °C and 100 °C
Standard
Optional
HEL-717-U-0-12-00
HEL-717-U-1-12-00
20
Glo_Comm_minicat_Iss3_FINAL .PMD
HEL-716-U-0-12-00
HEL-716-U-1-12-00
HEL-716-U-1-12-C2
www.honeywell.com/sensing
20
1/10/2006, 3:44 PM
REFERENCE
TD5A
TEMPERATURE - THERMISTORS
TEMPERATURE - THERMISTORS
Temperature Sensors - Thermistors
Thermistors change resistance with a change in temperature. They do
not amplify, rectify, polarize or generate a signal. The thermistor
temperature may be changed by the surrounding temperature or by
self-heating the thermistor by passing a current through it.
Most applications such as temperature measurement and control or
copper coil compensation require that the power dispersed in a
thermistor be kept to a minimum so as not to perceptibly self-heat the
thermistor. Other applications depend entirely on the self-heating effect.
When the surrounding temperature is fixed, the resistance of a
thermistor is largely a function of power being dispersed within it,
raising its temperature above its environment. Under these operating
conditions, the temperature may rise 100 °C to 200 °C [121 °F to
392 °F] and the resistance may be lowered to 1/1000th of its original
value at low current.
This self-heating characteristic provides a whole field of uses for the
thermistor. In the self-heat state it is thermally sensitive (its resistance
will be changed) to any condition, changing the rate at which heat is
conducted away from it. If the rate of heat removal is ideally fixed, then
the thermistor is sensitive to power input and suited for use in voltage
or power level control applications.
Glass Encapsulated Chip (GEC)
Thermistors
OPTIONS
At 25 °C [77 °F]
The GEC thermistors are high-quality, hermetically-sealed, glassencapsulated chip thermistors in an axial lead package. They cover the
full temperature range of -60 °C to 300 °C [-76 °F to 572 °F]. These
rugged sensors are designed for many applications which demand
reliability at low cost. The uniform dimensions often are ideally suited for
automated assembly.
Operating temperature:
-60 °C to 300 °C [-76 °F to 572 °F]
Encapsulation:
DO-35 glass
Lead material:
Tinned copper-clad steel
Dissipation constant (DC):
2.5 mW/°C in still air min.
Time constant (TC):
4 s in still air max.
Resistance range at 25 °C [77 °F]:
1 kOhm to 1 MOhm
CHIP
THERMISTOR
2,0 DIA.
[0.08]
GLASS
ENCAPSULATION
28,6
[1.125]
4,6
[0.81]
OHM
1,000
2,000
3,000
5,000
5,000
10,000
10,000
10,000
20,000
30,000
50,000
50,000
100,000
100,000
200,000
500,000
1M
% TOLERANCE
10
10
10
5
10
5
10
5
10
10
5
10
5
10
10
10
10
R/T CURVE
10A
10
10
10
10
10
16
16
16
16
16
16
16
16
1
1
1
REFERENCE
135-102DAG-J01
135-202FAG-J01
135-302FAG-J01
135-502FAF-J01
135-502FAG-J01
135-103FAF-J01
135-103FAG-J01
135-103LAF-J01
135-203LAG-J01
135-303KAG-J01
135-503LAF-J01
135-503LAG-J01
135-104LAF-J01
135-104LAG-J01
135-204QAG-J01
135-504QAG-J01
135-105QAG-J01
Interchangeable R/T curve matched
±1 °C from 0 °C to 100 °C [32 °F to 212 °F]
OHM
10,000
20,000
30,000
50,000
100,000
R/T CURVE
16
16
16
16
16
REFERENCE
135-103LFW-J01
135-203LFW-J01
135-303LFW-J01
135-503LFW-J01
135-104LFW-J01
0,51 DIA. TINNED COPPER CLAD STEEL
[0.020]
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
21
1/10/2006, 3:44 PM
21
TEMPERATURE - THERMISTORS
TEMPERATURE - THERMISTORS
Uncoated chip
Epoxy-coated or Uncoated Chip
Thermistors
Epoxy-coated or uncoated chip thermistors are available in a broad
range of custom resistance values and R/T curves. They are also
available in two lead types:
0,76 MAX
[0.030]
• Uninsulated: 0,2032 mm [0.008 in] diameter, tinned copper for
1 kOhm or less, and tinned copper alloy for greater than 1 kOhm.
1,40 ±0,51
[0.055 ±0.020]
1,40 ±0,51
[0.055 ±0.020]
®
• Insulated: 0,254 mm [0.010 in] diameter, nickel wire, Teflon -insulated,
38,1 mm [1.5 in] long and furnished with 6,35 mm [0.25 in] stripped
ends of 0,4064 mm [0.016 in] and 0,508 mm [0.020 in] tin-plated
copper leads.
Operating temperature range:
-40 °C to
Encapsulation:
Lead material:
• Uninsulated:
• Insulated:
125 °C [-40 °F to 257 °F]*
Epoxy-coated or uncoated
tinned copper/copper alloy
tinned copper/copper alloy
with nickel wire Teflon
Dissipation constant (DC):
0.75 mW/°C in still air min.
Time constant (TC):
15 s in still air max.
Resistance range at 25 °C [77 °F]:
100 Ohm to 100 kOhm
*Very accurate (±0.2 °C) when used between 0 °C to 70 °C
[32 °F to 158 °F]. Other ranges and tolerances are available.
10 % tolerance at 25 °C [77 °F], uninsulated leads
OHM
100
300
500
1,000
2,000
3,000
5,000
10,000
20,000
30,000
50,000
100,000
R/T CURVE
17
17
10A
10A
16
16
16
16
16
18
1
1
REFERENCE
195-101CAG-A01
195-301CAG-A01
195-501DAG-A01
195-102DAG-A01
195-202LAG-A01
195-302LAG-A01
195-502LAG-A01
195-103LAG-A01
195-203LAG-A01
195-303KAG-A01
195-503QAG-A01
195-104QAG-A01
10 % tolerance at 25 °C [77 °F], insulated leads
OPTIONS
Epoxy-coated chip
38,1
[1.50]
2,54 MAX
[0.10]
10 % tolerance at 25 °C [77 °F], uninsulated leads
OHM
100
300
500
1,000
2,000
3,000
5,000
10,000
20,000
30,000
50,000
100,000
R/T CURVE
17
17
10A
10A
16
16
16
16
16
18
1
1
OHM
100
300
500
1,000
2,000
3,000
5,000
10,000
20,000
30,000
50,000
100,000
R/T CURVE
17
17
10A
10A
16
16
16
16
16
18
1
1
REFERENCE
197-101CAG-A01
197-301CAG-A01
197-501DAG-A01
197-102DAG-A01
197-202LAG-A01
197-302LAG-A01
197-502LAG-A01
197-103LAG-A01
197-203LAG-A01
197-303KAG-A01
197-503QAG-A01
197-104QAG-A01
10 % tolerance at 25 °C [77 °F], insulated leads
OHM
100
300
500
1,000
2,000
3,000
5,000
10,000
20,000
30,000
50,000
100,000
R/T CURVE
17
17
10A
10A
16
16
16
16
16
18
1
1
22
Glo_Comm_minicat_Iss3_FINAL .PMD
REFERENCE
199-101CAG-A01
199-301CAG-A01
199-501DAG-A01
199-102DAG-A01
199-202LAG-A01
199-302LAG-A01
199-502LAG-A01
199-103LAG-A01
199-203LAG-A01
199-303KAG-A01
199-503QAG-A01
199-104QAG-A01
www.honeywell.com/sensing
22
1/10/2006, 3:44 PM
REFERENCE
198-101CAG-A01
198-301CAG-A01
198-501DAG-A01
198-102DAG-A01
198-202LAG-A01
198-302LAG-A01
198-502LAG-A01
198-103LAG-A01
198-203LAG-A01
198-303KAG-A01
198-503QAG-A01
198-104QAG-A01
TEMPERATURE - THERMISTORS
TEMPERATURE - THERMISTORS
UNI-CURVE® Interchangeable Thermistors
®
The UNI-CURVE Interchangeable thermistors are temperature-matched.
They offer additional cost savings by eliminating the need for individual
resistance temperature calibration, as well as standardization of circuit
components and simplification of design and replacement problems.
Operating temperature range:
-40 °C to 150 °C [-40 °F to 302 °F]*
Encapsulation:
Epoxy-coated
Lead material:
Tinned copper alloy
Dissipation constant (DC):
0.75 mW/°C in still air min.
Time constant (TC):
15 s in still air max.
Resistance range at 25 °C [77 °F]:
1 kOhm to 100 kOhm
*Very accurate (±0.2 °C) when used between 0 °C to 70 °C
[32 °F to 158 °F]. Other ranges and tolerances are available.
Disc Thermistors
Uncoated or epoxy-coated Disc thermistors are available in a broad
range of custom resistance values and R/T curves. They are only
available with uninsulated leads. Diameters range from 2,54 mm [0.1 in]
to 10,16 mm [0.4 in]. They are often ideally suited for low-cost
applications with a maximum temperature of 150 °C [302 °F]. They are
also typically well suited for PC board mount and are available on tape
and reel.
Operating temperature range:
-60 °C to 150 °C [-76 °F to 302 °F]
Encapsulation:
Epoxy-coated or uncoated
Lead material:
Uninsulated: tinned copper/copper alloy
Dissipation constant (DC):
Varies with size,
ranges from 3 mW/°C to 8 mW/°C
Time constant (TC):
Varies with size ranges from 10 s to 32 s
Resistance range at 25 °C [77 °F]:
100 Ohm to 100 kOhm
OPTIONS
38,1
[1.50]
2,4
[0.095]
Epoxy-coated chip
6,35
[0.25]
0,2032 DIA. TINNED COPPER ALLOY
[0.008]
OPTIONS
38,1
[1.50]
±0,2 °C tolerance at 25 °C [77 °F]
0 °C to 70 °C [32 °F to 158 °F]
OHM
1,000
2,252
3,000
5,000
10,000
30,000
30,000
50,000
100,000
R/T CURVE
10A
16
16
16
16
18
1
1
1
REFERENCE
192-102DET-A01
192-222LET-A01
192-302LET-A01
192-502LET-A01
192-103LET-A01
192-303KET-A01
192-303QET-A01
192-503QET-A01
192-104QET-A01
±0,5 °C tolerance at 25 °C [77 °F]
0 °C to 70 °C [32 °F to 158 °F]
OHM
1,000
2,252
3,000
5,000
10,000
30,000
30,000
50,000
100,000
R/T CURVE
10A
16
16
16
16
18
1
1
1
REFERENCE
192-102DEV-A01
192-222LEV-A01
192-302LEV-A01
192-502LEV-A01
192-103LEV-A01
192-303KEV-A01
192-303QEV-A01
192-503QEV-A01
192-104QEV-A01
±1,0 °C tolerance at 25 °C [77 °F]
0 °C to 70 °C [32 °F to 158 °F]
OHM
1,000
2,252
3,000
5,000
10,000
30,000
30,000
50,000
100,000
R/T CURVE
10A
16
16
16
16
18
1
1
1
REFERENCE
192-102DEW-A01
192-222LEW-A01
192-302LEW-A01
192-502LEW-A01
192-103LEW-A01
192-303KEW-A01
192-303QEW-A01
192-503QEW-A01
192-104QEW-A01
LEAD SPACING
10 % tolerance at 25 °C [77 °F]
Lead diameter 0,4064 mm [0.016 in]
Lead spacing 2,54 mm [0.1 in]
OHM
500
1,000
3,000
5,000
10,000
50,000
100,000
R/T CURVE
10
10
16
16
16
1
1
DC MIN.
3
4
3
4
4
3
3
23
REFERENCE
140-501FAG-RB1
140-102FAG-RB1
140-302LAG-RB1
140-502LAG-RB1
140-103LAG-RB1
140-503QAG-RB1
140-104QAG-RB1
10 % tolerance at 25 °C [77 °F]
Lead diameter 0,508 mm [0.020 in]
Lead spacing 5,08 mm [0.2 in]
OHM
100
200
300
1,000
3,000
5,000
10,000
30,000
50,000
R/T CURVE
10
10
10
16
16
16
1
1
1
DC MIN.
4
5
6
6
6
7
4
6
7
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
TC MAX.
10
10
10
10
10
10
10
1/10/2006, 3:44 PM
TC MAX.
16
18
20
20
22
35
20
25
30
REFERENCE
143-101FAG-RC1
143-201FAG-RC1
143-501FAG-RC1
143-102LAG-RC1
143-302LAG-RC1
143-502LAG-RC1
143-103QAG-RC1
143-303QAG-RC1
143-503QAG-RC1
23
TEMPERATURE - THERMISTORS
Uncoated chip
Standard Bead Thermistors
2,54
[0.10]
Standard Bead thermistors are hermetically-sealed in glass. These small
units provide maximum stability when used to 300 °C [572 °F] for high
temperature design requirements. They are often ideally suited for many
stringent military, aerospace and oceanographic applications.
Operating temperature range:
-60 °C to 300 °C [-76 °F to 572 °F]
Encapsulation:
Glass hermetic seal
Lead material:
Platinum iridium
Dissipation constant (DC):
0.4 mW/°C in still air min.
Time constant (TC):
4 s in still air max.
Resistance range at 25 °C [77 °F]:
200 Ohm to 1 MOhm
38,1
[1.50]
LEAD SPACING
OPTIONS
10 % tolerance at 25 °C [77 °F]
Lead diameter 0,4064 mm [0.016 in]
Lead spacing 2,54 mm [0.1 in]
OHM
500
1,000
3,000
5,000
10,000
50,000
100,000
R/T CURVE
10
10
16
16
16
1
1
DC MIN.
3
4
3
4
4
3
3
TC MAX.
10
10
10
10
10
10
10
REFERENCE
142-501FAG-RB1
142-102FAG-RB1
142-302LAG-RB1
142-502LAG-RB1
142-103LAG-RB1
142-503QAG-RB1
142-104QAG-RB1
10 % tolerance at 25 °C [77 °F]
Lead diameter 0,508 mm [0.020 in]
Lead spacing 5,08 mm [0.2 in]
OHM
100
200
300
500
1,000
3,000
5,000
10,000
30,000
50,000
R/T CURVE
10
10
10
10
16
16
16
1
1
1
DC MIN.
4
5
6
6
6
6
7
4
7
8
TC MAX.
16
18
20
25
20
22
35
20
28
32
2,29
[0.09]
9,5
[0.375]
REFERENCE
145-101FAG-RC1
145-201FAG-RC1
145-301FAG-RC1
145-501FAG-RC1
145-102LAG-RC1
145-302LAG-RC1
145-502LAG-RC1
145-103QAG-RC1
145-303QAG-RC1
145-503QAG-RC1
1,14 DIA.
[0.045]
0,1016 DIA.
[0.004]
Adjacent leads
20 % Tolerance at 25 °C [77 °F]
OHM
200
1,000
2,000
5,000
10,000
20,000
50,000
100,000
200,000
500,000
1M
R/T CURVE
8
11
11
11
12
13
14
15
15
4
5
RATIO 0 °C/50 °C
4.80
7.04
7.04
7.04
7.59
9.11
9.53
10.45
10.45
11.78
13.12
REFERENCE
112-201BAJ-B01
112-102EAJ-B01
112-202EAJ-B01
112-502EAJ-B01
112-103FAJ-B01
112-203HAJ-B01
112-503JAJ-B01
112-104KAJ-B01
112-204KAJ-B01
112-504NAJ-B01
112-105PAJ-B01
0,1016 DIA.
[0.004]
1,14 DIA
[0.045]
2,29
[0.090]
9,5
[0.375]
Axial leads
20 % Tolerance at 25 °C [77 °F]
OHM
2,000
5,000
10,000
100,000
600,000
24
Glo_Comm_minicat_Iss3_FINAL .PMD
R/T CURVE
11
11
12
15
4
www.honeywell.com/sensing
24
1/10/2006, 3:44 PM
RATIO 0 °C/50 °C
7.04
7.04
7.59
10.45
11.78
REFERENCE
112-202EAJ-H01
112-502EAJ-H01
112-103FAJ-H01
112-104KAJ-H01
112-604NAJ-H01
TEMPERATURE - THERMISTORS
Small Bead Thermistors
Glass Probe Thermistors
Small Bead Thermistors feature relatively uniform size, offer ultra-fast
time response and are highly sensitive to electric power. They are often
ideally suited for use in low heat capacity applications and their micro size
many times makes them perfect for use in extremely small assemblies
such as catheters and hypodermic needles. They are also often used in
self-heat applications such as gas analysis, gas flow measurement and
thermal conductivity analysis.
Glass Probe thermistors are shock resistant, rugged, glass-encapsulated
units that are ideally suited for immersion in fluid and convenient for
mounting in air sensor assemblies. They are available in two
configurations: standard and mini.
Operating temperature range:
-60 °C to 300 °C [-76 °F to 572 °F]
Encapsulation:
Glass hermetic seal
Lead material:
Platinum iridium
Dissipation constant (DC):
0.1 mW/°C in still air min.
Time constant (TC):
1 s in still air max.
Resistance range at 25 °C [77 °F]:
2 kOhm to 100 kOhm
Operating temperature range:
Encapsulation:
Lead material:
Dissipation constant (DC):
-60 °C to 300 °C [-76 °F to 572 °F]
Glass
Dumet (copper-clad Ni-Fe wire)
• Standard: 1.0 mW/°C in still air min.
• Mini: 0.7 mW/°C in still air min.
Time constant (TC):
• Standard: 22 s in still air max.
• Mini: 10 s in still air max.
Resistance range at 25 °C [77 °F]:
1 kOhm to 10 MOhm
OPTIONS
OPTIONS
2,51
[0.020]
9,5
[0.375]
50,8
[2.00]
0,36 DIA.
[0.014]
2,54
[0.10]
0,0254 DIA.
[0.001]
0,3048 DIA. DUMET
[0.012]
Adjacent leads
at 25 °C [77 °F]
OHM
2,000
8,000
30,000
% TOLERANCE
25
20
25
R/T CURVE
9
11
11
RATIO 0 °C/50 °C [32 °F/122 °F]
5.50
7.04
7.04
OHM
2,000
8,000
10,000
100,000
% TOLERANCE
25
20
20
25
REFERENCE
111-202CAK-B01
111-802EAJ-B01
111-303EAK-B01
0,0254 DIA.
[0.001]
0,36 DIA
[0.014]
0,51
[0.020]
Axial leads
at 25 °C [77 °F]
Standard
20 % Tolerance at 25 °C [77 °F]
dc 1.0 mW/°C min., TC 22 s max.
OHM
1,000
2,000
5,000
10,000
50,000
100,000
200,000
500,000
1M
10 M
R/T CURVE
11
11
11
12
14
15
15
4
5
6
9,5
[0.375]
31,5
[1.25]
RATIO
7.04
7.04
7.04
7.59
9.53
10.45
10.45
11.89
13.12
15.65
REFERENCE
121-102EAJ-Q01
121-202EAJ-Q01
121-502EAJ-Q01
121-103FAJ-Q01
121-502JAJ-Q01
121-104KAJ-Q01
121-202KAJ-Q01
121-504NAJ-Q01
121-105PAJ-Q01
121-106QAJ-Q01
12,7
[0.50]
1,5
[0.06]
R/T CURVE
9
11
11
13
RATIO 0 °C/50 °C [32 °F/122 °F]
5.50
7.04
7.04
9.11
REFERENCE
111-202CAK-H01
111-802EAJ-H01
111-103EAJ-H01
111-104HAK-H01
0,2032 DIA. DUMET
[0.008]
Mini
20 % Tolerance at 25 °C [77 °F]
dc 0.7 mW/°C min., TC 10 s max.
OHM
1,000
2,000
10,000
50,000
100,000
R/T CURVE
11
11
12
14
15
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
12,7
[0.50]
25
1/10/2006, 3:44 PM
RATIO
7.04
7.04
7.59
9.53
10.45
REFERENCE
120-102EAJ-Q01
120-202EAJ-Q01
120-103FAJ-Q01
120-502JAJ-Q01
120-104KAJ-Q01
25
TEMPERATURE - THERMISTORS
E-I Matched Bead Thermistors
ICL Inrush Current Limiter Thermistors
E-I Matched Bead thermistors are designed for use in many gas
chromatography and other thermal conductivity gas analysis
instruments. Each bead is mounted to a special hermetically-sealed
header. For maximum sensitivity, the higher resistance units should be
used at higher ambient temperatures.
ICL Inrush Current Limiter thermistors are a cost-effective way of limiting
the inrush of current that may damage components in a switching
power supply and in other power devices when the equipment is turned
on. These devices have solderable leads and are PC board mountable.
Operating temperature range:
Encapsulation:
Lead material:
-60 °C to 300 °C [-76 °F to 572 °F]
Glass hermetic seal
Tinned Ni-Fe
THERMISTOR
BEAD
12,7
[0.50]
9,65
[0.38]
31,75
[1.25]
Operating temperature range:
-40 °C to 185 °C [-40 °F to 365 °F]
Maximum steady state current:
1 A to 30 A
Encapsulation:
Black silicone
Lead material:
Tinned copper
Dissipation constant (DC):
12.7 mW/°C to 23 mW/°C
Time constant (TC):
32 s to 93 s
Resistance range at 25 °C [77 °F]:
0.5 Ohm to 220 Ohm ±20 %
Resistance at max. steady state current:
0.01 Ohm to 2.34 Ohm
Max. diameter:
9,5 mm [0.374 in] to 32.0 mm [1.260 in]
Max. thickness:
5,0 mm [0.204 in] to 8.0 mm [0.327 in]
Lead diameter:
0,8 mm [0.032 in] to 1.0 mm [0.040 in]
0,76 DIA.TINNED Ni-Fe
[0.03]
DIA.
OPTIONS
THICKNESS
Helium-matched assembly
Characteristics:
115-802EDJ-801
Resistance at 25 °C [77 °F]:
8000 Ohm ±25 %
Resistance at 0 °C [32 °F] (approx.):
23,200 Ohm
Resistance at 50 °C [122 °F] (approx.):
3,200 Ohm
Ratio of resisistance 0 °C/50 °C:
6.56 to 7.99
Beta nominal at 25 °C:
3495 K
Temperature coefficient at 25 °C:
-3.9 %/°C
Time constant (TC) still air max.:
1s
Dissipation constant (DC) still air min.:
0.16 mW/°C
DC helium:
0.5 mW/°C
Power rating (air):
45 mW
Power rating (helium):
140 mW
Max. ambient temperature:
250 °C [482 °F]
Max. operating temperature (including self-heat): 300 °C [572 °F]
Resisistance at max. operating temperature:
25 Ohm
2 % resistance at 25 °C [77 °F]
DESCRIPTION
Two 111-802EAJ-H01 each mounted on a glass hermetic seal and matched in
helium to within 30 mV, 25 mV and 20 mV of each other at 2 mA, 5 mA,
10 mA and 15 mA.
REFERENCE
115-802EDJ-801
Air-matched assembly
Characteristics:
115-202CDK-801
Resistance at 25 °C [77 °F]:
2000 Ohm ±25 %
Resistance at 0 °C [32 °F] (approx.):
4900 Ohm
Resistance at 50 °C [122 °F] (approx.):
890 Ohm
Ratio of resistance 0 °C/50 °C:
4.95 to 6.95
Beta nominal at 25 °C:
3000 K
Temperature coefficient at 25 °C:
-3.4 %/°C
Time constant (TC) still air max.:
1s
Dissipation constant (DC) still air min.:
0.16 mW/°C
DC helium:
0.5 mW/°C
Power rating (air):
15 mW
Power rating (helium):
60 mW
Max. ambient temperature:
100 °C [212 °F]
Max. operating temperature (including self-heat): 150 °C [302 °F]
Resisistance at max. operating temperature:
88 Ohm
25,4 MIN.
[1.00]
7,87 NOM.
[0.310]
OHM
0.5
1
1
2
2.5
2.5
2.5
5
5
10
10
10
10
10
12
16
20
40
50
80
120
220
MAX. STEADY
STATE CURRENT (A)
30
20
30
18
8
8
15
6
7
2
3.2
5
6
8
4
4
2
2
2
2.5
3
2
RESISTANCE AT MAX.
STEADY STATE CURRENT (OHM)
0.01
0.02
0.02
0.03
0.07
0.06
0.03
0.1
0.07
0.3
0.18
0.13
0.15
0.1
0.26
0.27
0.5
0.6
0.72
0.75
0.9
0.8
5 % resistance at 25 °C [77 °F]
DESCRIPTION
Two 111-202CAK-H01 each mounted on a glass hermetic seal and matched in
air to within 15 mV of each other at 5 mA, 10 mA and 15 mA.
26
Glo_Comm_minicat_Iss3_FINAL .PMD
REFERENCE
115-202CDK-801
www.honeywell.com/sensing
26
2.54 NOM.
[0.10]
1/10/2006, 3:44 PM
REFERENCE
ICL32OR530-01
ICL221R020-01
ICL321R030-01
ICL222R018-01
ICL152R508-01
ICL122R508-01
ICL222R515-01
ICL155R006-01
ICL155R007-01
ICL1010002-01
ICL1010004-01
ICL1210005-01
ICL1510006-01
ICL2210008-01
ICL1512004-01
ICL1516004-01
ICL1220002-01
ICL1240002-01
ICL1250002-01
ICL1580003-01
ICL2212103-01
ICL1522102-01
TEMPERATURE - PROBES
Temperature Sensors - Probes
Temperature Sensor Probes are finished thermistor assemblies complete
with thermistor housing, extension leads and usually a connector. A
variety of customized packages are available.
NOTE: The products in this section do not follow the “how to use this
catalogue” instructions provided in the catalogue introduction. Specific
reference numbers are not given due to their custom nature. Please
contact your local Honeywell sales office for ordering information.
ES120 Series Coolant/Oil Temperature
Sensor Probes
ES110 Series Inlet Air Temperature
Sensor Probes
The ES120 probe is a thermistor mounted into a plastic lead frame and
assembled into a metal body. This subassembly is then overmolded to
produce both the electrical connection system and the hexagonal shape
for easy installation. The all-plastic design reduces heat loss through the
sensor, thereby reducing wind chill effects.
The ES110 probe is a thermistor mounted into a plastic lead frame and
assembled into a metal body. This subassembly is then overmolded to
produce both the electrical connection system and the hexagonal shape
for easy installation. Two end configurations are available depending
upon response required or degree of protection. The all-plastic design
reduces heat loss through the sensor, thereby reducing wind chill effects.
Operating temperature range:
-40 °C to 155 °C [-40 °F to 311 °F]
Encapsulation:
NTC (Negative Temperature Coefficient) encapsulated
in thermal epoxy
Lead material:
Terminals are 2,8 mm x 0,8 mm [0.11 in x 0.03 in] brass
with a copper flash protection layer with final plating to
customer requirement (silver, tin, gold, etc.)
Dissipation constant:
Tor values (time to reach 63.2 % of the difference
between two temperatures) are typically 19 s rising
temperature and 14 s falling temperature
Time constant:
None
Resistance range at 25 °C [77 °F]
2.5 kOhm at 20 °C [68 °F] ±5 %
Operating temperature range:
-40 °C to 155 °C [-40 °F to 311 °F]
Encapsulation:
Standard NTC (Negative Temperature Coefficient) epoxy
protection
Lead material:
Terminals are 2,8 mm x 0,8 mm [0.11 in x 0.03 in]
brass with a copper flash protection layer with final plating
to customer requirement (silver, tin, gold, etc.)
Dissipation constant:
0.85 mW/°C in still air at 25 °C [77 °F]
Time constant:
1 s in liquids, 12 s max. in still air
Resistance range at 25 °C [77 °F]
2.5 kOhm at 20 °C [68 °F] ±5 %
SERIES NAME
ES120 Coolant/Oil Temperature Sensor Probe
SERIES NAME
ES110 Inlet Air Temperature Sensor Probe
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
27
1/10/2006, 3:44 PM
27
TEMPERATURE - PROBES
Air Conditioning Temperature Sensor
Probes
Earth Return (Ground) Temperature
Sensor Probes
A fully overmolded and protected sensor incorporating a specially
developed NTC (Negative Temperature Coefficient) to withstand many
very aggressive, damp operating conditions. The housing is snap fit
promoting easy assembly.
An all-metal temperature sensor, with the body being the ground,
incorporating a flat disc thermistor held flush on the base of the body by
a spring-loaded pressure pad. This sensor provides a quick response to
small variations in high temperature changes.
Operating temperature range:
-30 °C to 100 °C [-22 °F to 212 °F]
Encapsulation:
Special NTC epoxy coating
Lead material:
Terminals are 2,8 mm x 0,8 mm [0.11 in x 0.03 in]
brass with a copper flash protection layer with
final plating to customer requirement (silver, tin, gold, etc.)
Dissipation constant:
2.5 mW/°C in still air
Time constant:
2 s in water, 15 s max. in still air
Resistance range at 25 °C [77 °F]:
9 kOhm at 0 °C [32 °F] ±1.5 %
Operating temperature range:
Encapsulation:
NAME
Air Conditioning Temperature Sensor Probe
NAME
Earth Return (Ground) Temperature Sensor Probe
Refrigerant Temperature Sensor Probes
Surface Temperature Sensor Probes
A fully sealed, quick response temperature sensor suitable for use in
many HVAC systems.
Sensor assembly is designed to have good heat conductivity between the
thermistor element and the area to be monitored. Time response is
consistent with the thermal conductivity of the surface being measured.
Multiple configurations allow sensor to be mounted, bolted, riveted or
attached adhesively.
Operating temperature range:
-40 °C to 140 °C [-40 °F to 284 °F]
Encapsulation:
NTC (Negative Temperature Coefficient) encapsulated in a
thermal heat paste
Lead material:
Terminals are 1,5 mm x 0,6 mm [0.06 in x 0.02 in]
brass with a copper flash protection layer with final
plating to customer requirement (silver, tin, gold, etc.)
Dissipation constant:
Tor values (time to reach 63.2 % of the difference
between two temperatures) are typically 10 s
rising temperature and 6 s falling temperature
Time constant:
None
Resistance range at 25 °C [77 °F]:
2.5 kOhm at 20 °C [68 °F],
calibrated at ±3 % at 100 °C [212 °F]
Operating temperature range:
Encapsulation:
-60 °C to 150 °C [-76 °F to 302 °F]
Thermally conductive epoxy used to pot
discrete component into surface-style housing
Lead material:
Insulated lead wires and terminals when required, other
options available
Dissipation constant:
3.3 mW/°C to 12 mW/°C
(varies with size and housing style)
Time constant:
1 s to 40 s (application dependent)
Resistance range at 25 °C [77 °F]:
Per customer requirements
NAME
Surface Temperature Sensor Probe
NAME
Refrigerant Temperature Sensor Probe
28
Glo_Comm_minicat_Iss3_FINAL .PMD
-40 °C to 155 °C [-40 °F to 311 °F]
NTC (negative temperature coefficient)
encapsulated in a silicone paste
Lead material:
Standard Lucar type or other variations
Dissipation constant:
3 mW/°C in still air
Time constant:
10 s in automotive coolant
Resistance range at 25 °C [77 °F]:
Per customer requirements
www.honeywell.com/sensing
28
1/10/2006, 3:44 PM
TEMPERATURE - PROBES
Air/Gas Temperature Sensor Probes
Immersion Temperature Sensor Probes
Air/Gas probes contain an exposed thermistor element because gas is
not as good a heat conductor or thermal sink as a liquid, and because
time response is normally an important consideration. The sensor
housing may be composed of plastic or other thermally conductive
materials to reduce conduction and heat from the gas circulating around
the thermistor. Multiple configurations allow easy mounting.
Custom designed and application specific, immersion probes are
designed to be directly placed in the liquid medium to be measured. A
large variety of housing alloys are available. Multiple configurations allow
easy mounting.
Operating temperature range:
-60 °C to 150 °C [-76 °F to 302 °F]
Encapsulation:
None, sensing element is exposed
Lead material:
Insulated lead wires and terminals when required,
other options available
Dissipation constant:
0.1 mW/°C to 3 mW/°C (design specific)
Time constant:
4 s to 150 s (application and design dependent)
Resistance range at 25 °C [77 °F]:
Per customer requirements
Operating temperature range:
-60 °C to 300 °C [-76 °F to 572 °F]
Encapsulation:
NTC (Negative Temperature Coefficient) encapsulated in
housing appropriate to the application
Lead material:
Insulated lead wires and terminals when required,
other options available
Dissipation constant:
5 mW/°C to 10 mW/°C (varies with size
and housing style)
Time constant:
1 s to 12 s (design dependent)
Resistance range at 25 °C [77 °F]
Per customer requirements
NAME
Air/Gas Temperature Sensor Probe
NAME
Immersion Temperature Sensor Probe
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
29
1/10/2006, 3:44 PM
29
THERMAL CUTOFFS
Thermal Cutoffs
Thermal Cutoffs include products for use in a wide array of small
appliances, major appliances, office copy machines, automotive and
HVAC equipment. These devices are available in various lead lengths and
configurations. Honeywell offers versions that are compliant with
European Directive 2002/95/EC, otherwise known as RoHS (Restriction
of Hazardous Substances), in electrical and electronic equipment.
NOTE: The products in this section do not follow the “how to use this
catalogue” instructions provided in the catalogue introduction. Specific
reference numbers are not given due to their custom nature. Please
contact your local Honeywell sales office for ordering information.
NOTICE
• To maximize product life, use a 30 °C [86 °F] min. differential
between the operating ambient temperature at the fuse location
and the specified functioning temperature of the fuse being used.
Maintain a 40 °C [104 °F] min. differential between devices with
functioning temperatures above 200 °C [392 °F].
• Under no condition should the thermal cutoff be exposed to a
continuous normal temperature rating in excess of 200 °C
[392 °F]. Only proper testing of the above will determine the
selected thermal cutoff’s suitability within the application.
D Series
81,79
[3.220]
The D Series responds to temperature by interrupting an electrical circuit
when the operating and/or environmental temperature exceeds the
thermal rating of the fuse. This is accomplished when the organic pellet
experiences a phase change, allowing the spring activated contacts to
permanently open the circuit.
Operating temperature range:
Environmental exposure range:
35,05
[1.380]
46,74
[1.840]
11,61 REF.
[0.457]
SILVER-PLATED
BRASS CASE
72 °C to 240 °C [162 °F to 464 °F]
see notice
TIN-PLATED
18 AWG 1,02 [0.040]
COPPER WIRE
SILVER-PLATED
18 AWG 1,02 [0.040]
COPPER WIRE
NAME
DXXX-002
64,26
[2.530]
29,21
[1.150 ]
35,05
[1.380 ]
69,09
[2.720]
11,61 REF.
[0.457]
SILVER-PLATED
BRASS CASE
3,99
[0.157]
34,04
[1.340]
35,05
[1.380]
11,61 REF.
[0.457]
SILVER-PLATED
BRASS CASE
TIN-PLATED
18 AWG 1,02 [0.040]
COPPER WIRE
3,99
[0.157]
TIN-PLATED
18 AWG 1,02 [0.040]
COPPER WIRE
SILVER-PLATED
18 AWG 1,02 [0.040]
COPPER WIRE
NAME
DXXX-001
NAME
DXXX-003
30
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
30
1/10/2006, 3:44 PM
3,99
[0.157]
SILVER-PLATED
18 AWG 1,02 [0.040]
COPPER WIRE
THERMAL CUTOFFS
RD Series
The RD Series responds to temperature by interrupting an electrical
circuit when the operating and/or environmental temperature exceeds
the thermal rating of the fuse. This is accomplished when the organic
pellet experiences a phase change, allowing the spring activated
contacts to permanently open the circuit.
The electrical resistance of an RD Series thermal cutoff is comparable to
that found in an equal length of 18 gage solid copper wire. With proper
heat flow, heat generation below 15 A is minimal. Above 15 A, the upper
limit on current capacity will depend on the environment for each
specification.
Operating temperature range:
Environmental exposure range:
72 °C to 240 °C [162 °F to 464 °F]
see notice on previous page
NAME
RDXXX-001
NAME
RDXXX-002
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
31
1/10/2006, 3:45 PM
31
THERMOSTATS - REDI-TEMP®
Thermostats - Redi-Temp®
Redi-Temp® is a line of standard thermostat products offered in a range
of pre-set temperatures. These products are available standard for
immediate delivery. They are often useful for low-volume applications
where standard configurations are acceptable, as well as for evaluating
new designs and prototypes.
3455RC 15 A High Temperature Universal
Thermostat Series
Open on rise
Shipped from stock, the 3455RC Series thermostats are often suitable
for applications such as copy machines, power supplies,
telecommunications and ovens. UL, CSA and European approval
agencies listings available.
Electrical rating:
Housing material:
Operating temperature range:
Environmental exposure range:
15 A resisitive max., 120 Vac
High density ceramic base
0 °C to 150 °C [32 °F to 302 °F]
-18 °C to 288 °C [0 °F to 550 °F]
OPEN/CLOSE °F
65 ±5/30 ±8
75 ±5/40 ±8
85 ±5/55 ±8
95 ±5/65 ±8
105 ±5/75 ±8
115 ±5/85 ±8
125 ±5/95 ±8
135 ±5/105 ±8
145 ±5/115 ±8
155 ±5/125 ±8
165 ±5/135 ±8
175 ±5/145 ±8
185 ±5/155 ±8
195 ±5/165 ±8
205 ±6/175 ±8
215 ±6/185 ±8
225 ±6/195 ±8
235 ±6/205 ±8
245 ±6/215 ±8
255 ±7/225 ±8
275 ±7/245 ±8
295 ±7/265 ±8
315 ±10/275 ±15
OPEN/CLOSE °C
18 ±3/-1 ±5
24 ±3/4 ±5
29 ±3/13 ±5
35 ±3/18 ±5
41 ±3/24 ±5
46 ±3/29 ±5
52 ±3/35 ±5
57 ±3/41 ±5
63 ±3/46 ±5
68 ±3/52 ±5
73 ±3/57 ±5
79 ±3/63 ±5
85 ±3/68 ±5
91 ±3/73 ±5
96 ±4/79 ±5
102 ±4/85 ±5
107 ±4/91 ±5
113 ±4/96 ±5
118 ±4/102 ±5
124 ±4/107 ±5
135 ±4/118 ±5
146 ±4/129 ±5
157 ±6/135 ±8
REFERENCE
3455RC-100-220
3455RC-100-221
3455RC-100-222
3455RC-100-223
3455RC-100-224
3455RC-100-225
3455RC-100-226
3455RC-100-227
3455RC-100-228
3455RC-100-229
3455RC-100-230
3455RC-100-231
3455RC-100-232
3455RC-100-233
3455RC-100-234
3455RC-100-235
3455RC-100-236
3455RC-100-237
3455RC-100-238
3455RC-100-239
3455RC-100-240
3455RC-100-241
3455RC-100-242
CLOSE/OPEN °C
21 ±5/2 ±3
32 ±5/16 ±3
43 ±5/27 ±3
54 ±5/38 ±3
66 ±5/49 ±3
77 ±5/60 ±3
88 ±5/71 ±3
99 ±5/82 ±4
110 ±4/93 ±4
REFERENCE
3455RC-100-243
3455RC-100-244
3455RC-100-245
3455RC-100-246
3455RC-100-247
3455RC-100-248
3455RC-100-249
3455RC-100-250
3455RC-100-251
Close on rise
CLOSE/OPEN °F
70 ±8/35 ±5
90 ±8/60 ±5
110 ±8/80 ±5
130 ±8/100 ±5
150 ±8/120 ±5
170 ±8/140 ±5
190 ±8/160 ±5
210 ±8/180 ±6
230 ±8/200 ±6
32
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
32
1/10/2006, 3:45 PM
THERMOSTATS - REDI-TEMP®
3100 SPST Hermetic Thermostat Series
Shipped from stock, the 3100 Series thermostats are often suitable for
applications such as computers, medical electronics, power supplies,
industrial controls and test equipment. They feature a laser-welded
hermetic seal, are pre-set and tamper-proof. UL listings available.
Electrical rating:
Environmental exposure range:
30 A resisitive max., 120 Vac/240 Vac
-62 °C to 288 °C [-80 °F to 550 °F]
3600 Series Subminiature Thermostats
TO-5 Package
Shipped from stock, the 3600 Series thermostats feature logic-level
switching with gold contacts, have no power budget and are wave
solderable with a hermetic seal. They are often suitable for applications
such as power supplies, logic boards, telecommunications, medical
electronics and robotics.
Electrical rating:
Dielectric strength:
Operating temperature range:
Environmental exposure range:
15 A resisitive max., 120 Vac
500 Vac, 60 Hz for 1 s
-40 °C to 100 °C [-40 °F to 212 °F]
-50 °C to 177 °C [58 °F to 351 °F]
Open on rise
OPEN/CLOSE °F
40 ±5/20 ±5
50 ±5/30 ±5
60 ±5/40 ±5
70 ±5/50 ±5
80 ±5/60 ±5
90 ±5/70 ±5
100 ±5/80 ±5
110 ±5/90 ±5
120 ±5/100 ±5
130 ±5/110 ±5
140 ±5/120 ±5
150 ±5/130 ±5
160 ±5/140 ±5
170 ±5/150 ±5
180 ±5/160 ±5
190 ±5/170 ±5
200 ±5/180 ±5
210 ±8/185 ±6
220 ±8/195 ±6
230 ±8/205 ±6
240 ±8/215 ±6
250 ±8/225 ±6
OPEN/CLOSE °C
4 ±3/-7 ±3
10 ±3/-1 ±3
16 ±3/4 ±3
21 ±3/10 ±3
27 ±3/16 ±3
32 ±3/21 ±3
38 ±3/27 ±3
43 ±3/32 ±3
49 ±3/38 ±3
54 ±3/43 ±3
60 ±3/49 ±3
66 ±3/54 ±3
71 ±3/60 ±3
77 ±3/66 ±3
82 ±3/71 ±3
88 ±3/77 ±3
93 ±3/82 ±3
99 ±5/85 ±4
104 ±5/91 ±4
110 ±5/96 ±4
116 ±5/102 ±4
121 ±5/107 ±4
REFERENCE
3100U-3-1431
3100U-3-1432
3100U-3-1433
3100U-3-1434
3100U-3-1435
3100U-3-1436
3100U-3-1437
3100U-3-1438
3100U-3-1439
3100U-3-1440
3100U-3-1441
3100U-3-1442
3100U-3-1443
3100U-3-1444
3100U-3-1445
3100U-3-1446
3100U-3-1447
3100U-3-1448
3100U-3-1449
3100U-3-1450
3100U-3-1451
3100U-3-1452
Close on rise
OPTIONS
Open on rise
OPEN/CLOSE °C
40 ±5
45 ±5
50 ±5
55 ±5
60 ±5
65 ±5
70 ±5
75 ±5
80 ±5
85 ±5
90 ±5
95 ±5
100 ±5
REFERENCE
3600040010001
3600045010001
3600050010001
3600055010001
3600060010001
3600065010001
3600070010001
3600075010001
3600080010001
3600085010001
3600090010001
3600095010001
3600100010001
MIN DIFF. °C
2
2
2
5
5
5
5
5
5
7
7
7
7
REFERENCE
3601040010001
3601045010001
3601050010001
3601055010001
3601060010001
3601065010001
3601070010001
3601075010001
3601080010001
3601085010001
3601090010001
3601095010001
3601100010001
Close on rise
CLOSE/OPEN °F
40 ±5/20 ±5
50 ±5/30 ±5
60 ±5/40 ±5
80 ±5/60 ±5
100 ±5/80 ±5
120 ±5/100 ±5
140 ±5/120 ±5
160 ±5/140 ±5
180 ±5/160 ±5
200 ±5/180 ±5
220 ±6/195 ±8
CLOSE/OPEN °C
4 ±3/-7 ±3
10 ±3/-1 ±3
16 ±3/4 ±3
27 ±3/16 ±3
38 ±3/27 ±3
49 ±3/38 ±3
60 ±3/49 ±3
71 ±3/60 ±3
82 ±3/71 ±3
93 ±3/82 ±3
104 ±4/91 ±5
REFERENCE
3100U-3-1453
3100U-3-1454
3100U-3-1455
3100U-3-1456
3100U-3-1457
3100U-3-1458
3100U-3-1459
3100U-3-1460
3100U-3-1461
3100U-3-1462
3100U-3-1463
OPEN/CLOSE °C
40 ±7
45 ±7
50 ±7
55 ±7
60 ±7
65 ±7
70 ±7
75 ±7
80 ±7
85 ±7
90 ±7
95 ±7
100 ±7
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
MIN DIFF. °C
2
2
2
5
5
5
5
5
5
7
7
7
7
33
1/10/2006, 3:45 PM
33
THERMOSTATS - COMMERCIAL
Thermostats - Commercial
Commercial thermostats include products for use in a wide array of small
and major appliances, automotive applications, office copy machines,
heat and smoke detectors and HVAC equipment. These snap-action
thermostats include automatic or manual reset options, phenolic or
ceramic housings, and a variety of mounting brackets and terminal
options.
NOTE: The products in this section do not follow the “how to use this
catalogue” instructions provided in the catalogue introduction. Specific
reference numbers are not given due to their custom nature. Please
contact your local Honeywell sales office for ordering information.
NOTICE
Limitations: Type 2455RM/2450CM is intended as a manual reset
control. It is not to be used on applications where a limit thermostat
is required unless backup protection is provided. Units have been
tested by UL for 1,000 cycles under load, 5,000 cycles no load, and
are not considered limit devices.
WARNING
PERSONAL INJURY
Do not use the bi-metallic, snap action thermostat components as
final safety devices in any application. Their intended use is to
provide an electrical disruption in the application circuit in the event
of a change in temperature conditions.
Failure to comply with these instructions could result in death or
serious injury.
2450R/2450HR/2455R Series Phenolic
Automatic Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product. These products are factory calibrated to the customer’s
specification.
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
Automatic
15 A resistive max.
Phenolic
0 °C to 150 °C [32 °F to 302 °F]
0 °C to 150 °C [32 °F to 302 °F]
14,43 DIA.
[0.568]
9,63
[0.379]
16,0 DIA.
[0.630]
SERIES NAME
2450R Phenolic Automatic Reset Thermostat
34
Glo_Comm_minicat_Iss3_FINAL .PMD
6,73
[0.265]
13,94
[0.549]
12,34
9,12 [0.486]
[0.359]
14,43 DIA.
[0.568]
16,0 DIA.
[0.630]
SERIES NAME
2450HR Phenolic Automatic Reset Thermostat
14,43 DIA.
[0.568]
0,51
[0.020]
11,91
[0.469]
16,0 DIA.
[0.630]
SERIES NAME
2455R Phenolic Automatic Reset Thermostat
www.honeywell.com/sensing
34
2,36 [0.093] DIA.
1,57 [0.062] DEEP
1/10/2006, 3:45 PM
0,51
[0.020]
THERMOSTATS - COMMERCIAL
2450RC/2450RCH/2455RC Series
Ceramic Automatic Reset Thermostats
2450CM/2455RM Series Ceramic and
Phenolic Manual Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product.
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. The circuit will stay open above room ambient
temperature until the manual reset button is pressed. Response to
temperature changes is extremely rapid due to the inherently low mass
of the disc and the small size of the product.
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Automatic
15 A resistive max.
Ceramic
0 °C to 260 °C [32 °F to 500 °F]
-20 °C to 287 °C [0 °F to 550 °F]
Manual
15 A resistive max.
Ceramic or phenolic
52 °C to 232 °C [125 °F to 450 °F] (ceramic)
52 °C to 150 °C [125 °F to 302 °F] (phenolic)
Environmental exposure range: 10 °C to 260 °C [50 °F to 500 °F] (ceramic)
10 °C to 150 °C [50 °F to 302 °F] (phenolic)
1,04 [0.041] MAX TRAVEL OF
RESET BUTTON
ON CONTACT OPENING
16,00
[0.379]
15,98
[0.629]
14,48
12,90 [0.570]
[0.508]
14,43 DIA.
[0.568]
9,55
9,04 [0.376]
[0.356]
9,63
[0.379]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
2450RC Ceramic Automatic Reset Thermostat
SERIES NAME
2450CM Ceramic Manual Reset Thermostat
14,48
[0.570]
12,90
9,04 [0.508]
[0.356]
16,0 DIA.
[0.630]
15,88 ON CONTACT
[0.625] CLOSING
14,43 DIA.
[0.568]
11,91
[0.469]
16,0 DIA.
[0.630]
ENCLOSED DISK
0,51
[0.020]
SERIES NAME
2455RM Phenolic Manual Reset Thermostat
SERIES NAME
2450RCH Ceramic Automatic Reset Thermostat
14,43 DIA.
[0.568]
1,04 [0.041] MAX TRAVEL
OF RESET BUTTON ON
CONTACT OPENING
2,77 DIA. RESET
[0.109] BUTTON
2,36 [0.093] DIA.
1,57 [0.062] DEEP
14,43 DIA.
[0.568]
0,51
[0.020]
11,91
[0.469]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
2455RC Ceramic Automatic Reset Thermostat
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
35
1/10/2006, 3:45 PM
35
THERMOSTATS - COMMERCIAL
2450A/2455RA Series Heat Detection
Thermostats
The gold contacts open or close on a temperature rise of 47 °C to 107 °C
[117 °F to 225 °F].
Reset type:
Automatic
Amperage capacity:
15 A resistive max.
Housing material:
Phenolic, epoxy-sealed cap and terminals
Operating temperature range:
47 °C to 107 °C [117 °F to 225 °F]
Environmental exposure range:
0 °C to 150 °C [32 °F to 302 ° F]
9,63
[0.379]
0,51
[0.020]
SERIES NAME
2450A Heat Detection Thermostat
2450R/2450RCH/2455R/2455RCH/
2467RC/2467RCH Series “One-shot”
½ in Thermostats
Products are designed for high limit applications where automatic reset
is not desired.
Reset type:
Amperage capacity:
None
15 A resistive max.
21 A resistive max. (2467RC/2467RCH Series)
Housing material:ceramic or phenolic, with or without epoxy-sealed cap
and terminal
Operating temperature range: 52 °C to 260 °C [125 °F to 500 °F] (ceramic)
52 °C to 250 °C [125 °F to 500 °F] (ceramic) (2467RC Series)
52 °C to 150 °C [125 °F to 302 °F] (phenolic)
Environmental exposure range: -18 °C to 316 °C [0 °F to 600 °F] (ceramic)
-18 °C to 150 °C [0 °F to 302 °F] (phenolic)
14,43 DIA.
[0.568]
16,0 DIA.
[0.630]
11,91
[0.469]
0,51
[0.020]
9,63
[0.379]
0,51
[0.020]
SERIES NAME
2450R Phenolic “One-shot” ½ in Thermostat
2,36 [0.093] DIA.
1,57 [0.062] DEEP
SERIES NAME
2455A Heat Detection Thermostat
2455RBV Series Overmolded Automatic
Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product.
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
Automatic
15 A resistive max.
Ceramic or phenolic, epoxy overmold
-12 °C to 105 °C [10 °F to 221 °F]
-18 °C to 121 °C [0 °F to 250 °F]
14,48
[0.570]
12,90
9,04 [0.508]
[0.356]
14,43 DIA.
[0.568]
16,0 DIA.
[0.630]
ENCLOSED DISK
SERIES NAME
2450RCH Ceramic “One-shot” ½ in Thermostat
2467RCH Ceramic “One-shot” ½ in Thermostat
14,43 DIA.
[0.568]
11,91
[0.469]
AS REQUIRED
16,0 DIA.
[0.630]
WIRE GAGE AND
INSULATION AS
REQUIRED
AS REQUIRED
18,54
[0.730]
17,27 DIA.
[0.680]
SERIES NAME
2455RBV Overmolded Automatic Reset Thermostat
36
Glo_Comm_minicat_Iss3_FINAL .PMD
SERIES NAME
2455R Phenolic “One-shot” ½ in Thermostat
14,43 DIA.
[0.568]
11,91
[0.469]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
2455RC Ceramic “One-shot” ½ in Thermostat
2467RC Ceramic “One-shot” ½ in Thermostat
www.honeywell.com/sensing
36
0,51
[0.020]
1/10/2006, 3:45 PM
0,51
[0.020]
THERMOSTATS - COMMERCIAL
2450R Series Annular Ring Cap
Automatic Reset Thermostats
2450R Series Fully Sealed Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product.
Reset type:
Amperage capacity:
Housing material:
Automatic
15 A resistive, 12 Vdc
Phenolic, can be partially or totally sealed
against water ingress
Operating temperature range:
-10 °C to 55 °C [14 °F to 131 °F]
Environmental exposure range:
-40 °C to 130 °C [-40 °F to 266 °F]
Life cycle capability:
300 K at 12 Vdc, 10 A
Low temperature differential:
Down to 8 °C [46 °F]
Switch temperature tolerance:
±3 °C
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product.
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
Life cycle capability:
Low temperature differential:
Switch temperature tolerance:
Automatic
15 A resistive, 12 Vdc
Phenolic housing, aluminium cap totally
encapsulated in water-resistant epoxy
-10 °C to 55 °C [14 °F to 131 °F]
-40 °C to 130 °C [-40 °F to 266 °F]
300 K at 12 Vdc, 10 A
Down to 8 °C [46 °F]
±3 °C
16,1 MAX.
[0.63]
14,43 DIA.
[0.568]
9,63
[0.379]
16,0 DIA.
[0.630]
11,5
[0.45]
0,51
[0.020]
SERIES NAME
2450R Phenolic Annular Ring Cap Automatic Reset Thermostat
2450R/2455R Series Protected
Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Basic thermostat is protected from the environment
by sealing it in a metal housing or encapsulating it in epoxy.
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
SERIES NAME
2450R Fully Sealed Thermostat
Automatic
15 A resistive, 12 Vdc
Brass, aluminium, stainless steel and epoxy
15 °C to 130 °C [59 °F to 266 °F]
-40 °C to 155 °C [-40 °F to 311 °F]
SERIES NAME
2450R Protected Thermostat
2455R Protected Thermostat
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
37
1/10/2006, 3:45 PM
37
THERMOSTATS - COMMERCIAL
Standard Terminal Guide
Horizontal Solder
Vertical Solder Inside
T-101
T-106
T-147
T-146
Special Terminals
T-140
3/16 in Quick Connect,
Flat
T-149
3/16 in Quick Connect
Vertical
T-150
Specify Crimp Direction
Up or Down
T-102
38
Glo_Comm_minicat_Iss3_FINAL .PMD
T-107
1/4 in Quick Connect,
Vertical
1/4 in Quick Connect,
Horizontal
Vertical Solder Outside
T-103
T-105
T-120
T-121
T-115
www.honeywell.com/sensing
38
1/10/2006, 3:45 PM
THERMOSTATS - COMMERCIAL
Standard Terminal Guide (continued)
1/4 in Quick Connect, 45° 3/16 in Quick Connect, 45° Spade Terminal
Horizontal Weld Tab
T-141
T-151
T-148
T-161
T-162
T-167
T-165
T-164
T-168
T-160
T-169
T-166
T-170
T-178
T-179
T-188
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
39
1/10/2006, 3:45 PM
39
THERMOSTATS - COMMERCIAL
Standard Mounting Bracket Guide
Stationary Surface Brackets
Moveable Surface Brackets
B-201/B-201A/B-201B
B-203/B-203A/B-203B
Air Stream Brackets
B205/B205A
Special Mounting Brackets
B-206
B-207
B-212/B-212A
B-213
40
Glo_Comm_minicat_Iss3_FINAL .PMD
B-209
B-210
B-230
B-239
www.honeywell.com/sensing
40
1/10/2006, 3:45 PM
THERMOSTATS - COMMERCIAL
Standard Mounting Bracket Guide (continued)
B-249
B-246
B-250
Mounting Studs
Brass Hex Stud Mount
B-220-B-227
B-240
Bracket/Terminal Orientation (Intermediate angles available on specific request.)
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
41
1/10/2006, 3:45 PM
41
THERMOSTATS - PRECISION
Thermostats - Precision
Precision snap-action thermostats include both hermetic and nonhermetic devices for use in a wide array of applications including
computers, copy machines, aircraft, radar equipment, medical
equipment and electronic control systems. We also offer custompackaged thermostats for application flexibility and industrial-grade
thermostats designed to operate in extreme environmental conditions.
NOTE: The products in this section do not follow the “how to use this
catalogue” instructions provided in the catalogue introduction. Specific
reference numbers are not given due to their custom nature. Please
contact your local Honeywell sales office for ordering information.
NOTICE
Limitations: Type 3455RM/3450CM is intended as a manual reset
control. It is not to be used on applications where a limit thermostat
is required unless backup protection is provided. Units have been
tested by UL for 1,000 cycles under load, 5,000 cycles no load, and
are not considered limit devices.
WARNING
PERSONAL INJURY
3001/3004 Series Non-Hermetic
Thermostats
Do not use the bi-metallic, snap action thermostat components as
final safety devices in any application. Their intended use is to
provide an electrical disruption in the application circuit in the event
of a change in temperature conditions.
Failure to comply with these instructions could result in death or
serious injury.
The 3001/3004 Series are factory pre-set, single pole, single throw
thermal switches available to open and close on temperature rise. The
phenolic base is made dust-proof by a metal closure which also provides
thermal and electrical isolation for the silver contacts. The low silhouette
design of the 3001 Series makes it an excellent choice where a nonhermetic precision unit is required for tight tolerances. The 3004 Series
offers a metal sleeve insert-rivet construction and higher spacing to meet
European approval agency requirements. It is also UL recognized and
CSA certified.
Amperage:
1 A to 3 A (3001, 3001U Series)* 2 A to 4 A (3004 Series)*
Housing material:
Phenolic base with metal closure
Operating temperature range:
-18 °C to 168 °C [0 °F to 335 °F]
Environmental exposure range:
-18 °C to 177 °C [0 °F to 350 °F]
Dielectric strength:
MIL-STD-202, Method 301
1500 Vac 60 Hz terminal to case (2000 Vac 3004)
Insulation resistance:
MIL-STD-202, Method 302, Cond. B
500 MOhm, 500 Vdc applied
Contact resistance:
MIL-STD-202, Method 307, 50 mOhm
Hermetic seal:
MIL-STD-202, Method 112, Cond. A, 1x10-5 atm cc/s
Moisture resistance:
MIL-STD-202, Method 106
*Based on 240 Vac and life-cycle dependent. Call for further details.
42
Glo_Comm_minicat_Iss3_FINAL .PMD
SERIES NAME
3001 Series Non-Hermetic Thermostat
3001U Series Non-Hermetic Thermostat
3004 Series Non-Hermetic Thermostat
www.honeywell.com/sensing
42
1/10/2006, 3:45 PM
THERMOSTATS - PRECISION
3100/3106 Series Hermetic Thermostats
The 3100/3106 Series is a single pole, single throw switch activated by a
snap-action bimetal disc. Temperature calibrations are pre-set at the
factory and each unit is 100 % thermally and mechanically inspected. It is
available to open or close on temperature rise. The case is laser welded to
form a hermetically-sealed steel housing with a glass-to-metal seal at the
terminal junction. It is manufactured and tested to meet or exceed critical
commercial and industrial specifications. The 3106 Series has gold alloy
contacts for low voltage applications.
0.5 A resistive (3106 Series)
7 A resistive (3100 Series)
Housing material:
Steel housing with glass-to-metal
seal at terminal junction
Operating temperature range: -29 °C to 260 °C [-20 °F to 500 °F] (3100 Series)
-29 °C to 204 °C [-20 °F to 400 °F] (3106 Series)
Environmental exposure range:
-62 °C to 288 °C [-80 °F to 550 °F]
Dielectric strength:
MIL-STD-202, Method 301
1250 Vac 60 Hz terminal to case (3100, 3100U, 3106 Series)
1500 Vac 60 Hz terminal to case (3100UX Series)
Insulation resistance:
MIL-STD-202, Method 302, Cond. B
50 MOhm, 500 Vdc applied
Contact resistance:
MIL-STD-202, Method 307
25 mOhm (3106 Series)
50 mOhm (3100 Series)
Hermetic seal:
MIL-STD-202, Method 112, Cond. A
1x10-5 atm cc/s
Moisture resistance:
MIL-STD-202, Method 106
3150/3156 Series Low Silhouette
Hermetic Thermostats
The 3150/3156 Series is a single pole, single throw switch activated by a
snap-action bimetal disc. Temperature calibrations are pre-set at the
factory and each unit is 100 % thermally and mechanically inspected. It is
available to open or close on temperature rise. The case is laser welded to
form a hermetically-sealed steel housing with a glass-to-metal seal at the
terminal junction. The low silhouette and compact design often make it
especially well suited for applications that require miniaturization. The
3156 Series has gold alloy contacts for low voltage applications.
Amperage:
SERIES NAME
3100 Hermetic Thermostat
3100U Hermetic Thermostat
3100UX Hermetic Thermostat
3106 Hermetic Thermostat
Amperage:
0.5 A resistive (3156 Series)
7 A resistive (3150 Series)
Housing material:
Steel housing with glass-to-metal seal at
terminal junction
Operating temperature range:
-29 °C to 177 °C [-20 °F to 350 °F]
Environmental exposure range:
-62 °C to 260 °C [-80 °F to 500 °F]
Dielectric strength:
MIL-STD-202, Method 301
750 Vac 60 Hz terminal to case (3150, 3156 Series)
1250 Vac 60 Hz terminal to case (3150U, 3156U Series)
1500 Vac 60 Hz terminal to case (3150UX Series)
Insulation resistance:
MIL-STD-202, Method 302, Cond. B
50 MOhm, 500 Vdc applied
Contact resistance:
MIL-STD-202, Method 307
25 mOhm (3156 Series)
50 mOhm (3150 Series)
Hermetic seal:
MIL-STD-202, Method 112, Cond. A
1x10-5 atm cc/s
Moisture resistance:
MIL-STD-202, Method 106
SERIES NAME
3150 Low Silhouette Hermetic Thermostat
3150U Low Silhouette Hermetic Thermostat
3150UX Low Silhouette Hermetic Thermostat
3156 Low Silhouette Hermetic Thermostat
3156U Low Silhouette Hermetic Thermostat
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
43
1/10/2006, 3:45 PM
43
THERMOSTATS - PRECISION
3600/3601 Series TO-5 Thermal Switches
The 3600/3601 Series is a single pole, single throw, bimetal snap-action
switch available to open or close on temperature rise. These devices are
specifically designed and often suited for mounting on products such as
printed circuit boards to protect against hazardous temperatures
associated with the thermal density of components on backplanes,
flexible circuitry and sophisticated time-based circuits.
Amperage:
1 A resistive
Housing material:
nickel
Operating temperature range:
40 °C to 120 °C [104 °F to 248 °F]
Environmental exposure range:
-50 °C to 150 °C [-58 °F to 302 °F]
Dielectric strength:
500 Vac 60 Hz for one second, terminal to case
Insulation resistance:
20 MOhm at 500 Vdc
Contact resistance:
60 MOhm
Hermetic seal:
1x10-3 atm cc/s
SERIES NAME
3600 Series TO-5 Thermal Switch
3601 Series TO-5 Thermal Switch
44
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
44
1/10/2006, 3:45 PM
THERMOSTATS - PRECISION
3000 Series Custom-packaged
Thermostats
The 3000 Series incorporates a Honeywell thermostat assembled in a
custom package for use in a variety of applications that require flexibility
in mounting and terminal configurations. A typical product includes a
3100 hermetic internal thermostat with a terminal selection, housing
selection and customized part number. These custom package devices
operate in many extreme environmental conditions, such as exposure to
hazardous substances, dust particles and liquid immersion.
Amperage:
Housing material:
Operating temperature range:
Environmental exposure range:
Dielectric strength:
Insulation resistance:
7 A resistive
Stainless steel or brass
-29 °C to 260 °C [-20 °F to 500 °F]
-62 °C to 288 °C [-80 °F to 550 °F]
MIL-STD-202, Method 301
1250 Vac 60 Hz terminal to case
Contact resistance:
Hermetic seal:
Moisture resistance:
Terminations for 3000-45X* and 3000-55X* Housings
Terminations for 3000-53X*
and 3000-141 Housings
1
0
MIL-STD-202, Method 302
50 MOhm to 500 MOhm
MIL-STD-202, Method 307
50 mOhm max.
MIL-STD-202, Method 112, Condition A
1 x 10-5 atm cc/s
MIL-STD-202 Method 106
WIRE LEADS,
LENGTHS
AS REQ'D.
1
6,35 [0.25] MALE
QUICK CONNECTS
2a
HERMETIC
CONNECTOR
BAYONET
OR THREADED
WIRE LEADS,
LENGTHS
AS REQ'D.
2a
6,35 [0.25] MALE
QUICK CONNECTS
3
WIRE LEADS,
LENGTHS
AS REQ'D.
2b
6,35 [0.25] MALE
QUICK CONNECTS
60˚
REF.
2b
6,35 [0.25] MALE
QUICK CONNECTS
60˚
REF.
Housings
1/2 - 14 NPT
THREAD
3000-45X*
Housings
25,4 [1.00]
3000-53X*
3/4 - 16 UNF-3A
THREAD
4a
6,35 [0.25] MALE
QUICK CONNECTS
22,26 [0.875]
PROBE
LENGTH
1/2 - 14 NPT
THREAD
1/2 - 14 NPT
THREAD
SENSING SURFACE
SENSING SURFACE
3000-55X*
4b
60˚
REF.
6,35 [0.25] MALE
QUICK CONNECTS
3000-141
22,26 [0.875]
25,4 [1.00]
1/2 - 14 NPT
THREAD
1/2 - 14 NPT
THREAD
3/4 - 16 UNF - 3A
THREAD
PROBE
LENGTH
SENSING SURFACE
SERIES NAME
3000 Custom-packaged Thermostat
SENSING SURFACE
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
45
1/10/2006, 3:45 PM
45
THERMOSTATS - PRECISION
3800 Series Industrial-grade Thermostats
for Severe Duty Applications
3450R/3450HR/3455R Series Phenolic
Automatic Reset Thermostats
The 3800 Series is often used where high levels of vibration and
mechanical shock are common but a military device is not required. It is
easily customized for use in a variety of applications.
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product. These products are factory calibrated to the customer’s
specification.
Amperage:
7 A resistive
Housing material:
Steel housing with glass-to-metal seal at terminal junction
Operating temperature range:
-29 °C to 260 °C [-20 °F to 500 °F]
Environmental exposure range:
-62 °C to 260 °C [-80 °F to 500 °F]
Dielectric strength:
MIL-STD-202, Method 301
1250 Vac terminal to case
Insulation resistance:
MIL-STD-202, Method 302, Cond. B
50 MOhm min. terminal to case
Contact resistance:
MIL-STD-202, Method 307
50 mOhm max.
Hermetic seal:
MIL-STD-202, Method 112, Cond. A
1 x 10-5 atm cc/s
Moisture resistance:
MIL-STD-202, Method 106
Vibration (random):
MIL-STD-202, Method 214
30 g, 20 Hz to 2,000 Hz
Vibration (sinusoidal):
MIL-STD-202, Method 204,
Condition D 20 G, 20 Hz to 2,000 Hz
Mechanical shock:
MIL-STD-202, Method 213, 400 G
Thermal shock:
MIL-STD-202, Method 107, Cond. B
Acceleration:
MIL-STD-202, Method 212, 20 G
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
14,43 DIA.
[0.568]
Automatic
15 A resistive max.
Phenolic
0 °C to 150 °C [32 °F to 302 °F]
0 °C to 150 °C [32 °F to 302 °F]
9,63
[0.379]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
3450R Phenolic Automatic Reset Thermostat
6,73
[0.265]
2,36 [0.093] DIA.
1,57 [0.062] DEEP
13,94
[0.549]
12,34
9,12 [0.486]
[0.359]
14,43 DIA.
[0.568]
16,0 DIA.
[0.630]
SERIES NAME
3450HR Phenolic Automatic Reset Thermostat
SERIES NAME
3800 Industrial Grade Thermostat
14,43 DIA.
[0.568]
11,91
[0.469]
16,0 DIA.
[0.630]
SERIES NAME
3455R Phenolic Automatic Reset Thermostat
46
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
46
1/10/2006, 3:45 PM
0,51
[0.020]
THERMOSTATS - PRECISION
3450RC/3450RCH/3455RC Series
Ceramic Automatic Reset Thermostats
3450CM/3455RM Series Ceramic and
Phenolic Manual Reset Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product.
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. The circuit will stay open above room ambient
temperature until the manual reset button is pressed. Response to
temperature changes is extremely rapid due to the inherently low mass
of the disc and the small size of the product.
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Automatic
15 A resistive max.
Ceramic
0 °C to 260 °C [32 °F to 500 °F]
-20 °C to 287 °C [0 °F to 550 °F]
Manual
15 A resistive max.
Ceramic or phenolic
52 °C to 232 °C [125 °F to 450 °F] (ceramic)
52 °C to 150 °C [125 °F to 302 °F] (phenolic)
Environmental exposure range: 10 °C to 260 °C [50 °F to 500 °F] (ceramic)
10 °C to 150 °C [50 °F to 302 °F] (phenolic)
16,00
[0.379]
1,04 [0.041] MAX TRAVEL OF
RESET BUTTON
ON CONTACT OPENING
15,98
[0.629]
14,48
12,90 [0.570]
[0.508]
9,63
[0.379]
0,51
[0.020]
14,43 DIA.
[0.568]
SERIES NAME
3450RC Ceramic Automatic Reset Thermostat
9,55
9,04 [0.376]
[0.356]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
3450CM Ceramic Manual Reset Thermostat
2,36 [0.093] DIA.
1,57 [0.062] DEEP
14,48
[0.570]
12,90
9,04 [0.508]
[0.356]
14,43 DIA.
[0.568]
16,0 DIA.
[0.630]
ENCLOSED DISK
1,04 [0.041] MAX TRAVEL
OF RESET BUTTON ON
CONTACT OPENING
2,77 DIA. RESET
[0.109] BUTTON
SERIES NAME
3450RCH Ceramic Automatic Reset Thermostat
15,88 ON CONTACT
[0.625] CLOSING
14,43 DIA.
[0.568]
11,91
[0.469]
16,0 DIA.
[0.630]
14,43 DIA.
[0.568]
11,91
[0.469]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
3455RM Phenolic Manual Reset Thermostat
0,51
[0.020]
SERIES NAME
3455RC Ceramic Automatic Reset Thermostat
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
47
1/10/2006, 3:46 PM
47
THERMOSTATS - PRECISION
3455RBV Series Overmolded Automatic
Reset Thermostats
3450R/3450RC/3450RCH/3455R/3455RC
Series “One-shot” ½ in Thermostats
A temperature-sensitive bimetal disc, electrically isolated from the switch,
actuates the normally closed contacts. The contacts open when the
surface or ambient temperatures increase to the operating snap point of
the calibrated disc. Response to temperature changes is extremely rapid
due to the inherently low mass of the disc and the small size of the
product.
Products are designed for high limit applications where automatic reset is
not desired.
Reset type:
Amperage capacity:
Housing material:
Operating temperature range:
Environmental exposure range:
Automatic
15 A resistive max.
Ceramic or phenolic, epoxy overmold
-12 °C to 105 °C [10 °F to 221 °F]
-18 °C to 121 °C [0 °F to 250 °F]
Reset type:
None
Amperage capacity:
15 A resistive max.
Housing material: Ceramic or phenolic, with or without epoxy-sealed cap and
terminals
Operating temperature range: 52 °C to 260 °C [125 °F to 500 °F] (ceramic)
52 °C to 150 °C [125 °F to 302 °F] (phenolic)
Environmental exposure range: -18 °C to 287 °C [0 °F to 550 °F] (ceramic)
-18 °C to 150 °C [0 °F to 302 °F] (phenolic)
AS REQUIRED
14,43 DIA.
[0.568]
WIRE GAGE AND
INSULATION AS
REQUIRED
16,0 DIA.
[0.630]
AS REQUIRED
0,51
[0.020]
SERIES NAME
3450R Phenolic “One-shot” ½ in Thermostat
18,54
[0.730]
17,27 DIA.
[0.680]
9,63
[0.379]
0,51
[0.020]
16,00
[0.379]
SERIES NAME
3455RBV Overmolded Automatic Reset Thermostat
9,63
[0.379]
0,51
[0.020]
SERIES NAME
3450RC Ceramic “One-shot” ½ in Thermostat
2,36 [0.093] DIA.
1,57 [0.062] DEEP
14,48
[0.570]
12,90
9,04 [0.508]
[0.356]
14,43 DIA.
[0.568]
16,0 DIA.
[0.630]
SERIES NAME
3450RCH Ceramic “One-shot” ½ in Thermostat
48
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
48
1/10/2006, 3:46 PM
ENCLOSED DISK
THERMOSTATS - PRECISION
3450R/3450RC/3450RCH/3455R/3455RC
Series “One-shot” ½ in Thermostats
(continued)
14,43 DIA.
[0.568]
11,91
[0.469]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
3455R Phenolic “One-shot” ½ in Thermostat
14,43 DIA.
[0.568]
11,91
[0.469]
16,0 DIA.
[0.630]
0,51
[0.020]
SERIES NAME
3455RC Ceramic “One-shot” ½ in Thermostat
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
49
1/10/2006, 3:46 PM
49
THERMOSTATS - PRECISION
Standard Terminal Guide: Hermetic Thermostats Only
3100/3106 Series
T-116
T-117
T-120
T-110
T-111
3150/3156 Series
T-109
Note: Terminal thickness 0,41 [0.016] REF unless specified.
3305/3306 Series
T-133
T-134
T-135
Note: Terminal thickness 0,25 [0.010] REF unless specified.
50
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
50
1/10/2006, 3:46 PM
THERMOSTATS - PRECISION
Standard Terminal Guide: Hermetic Thermostats Only (continued)
Hermetic Radius Cap
(Except 3305/3306 Series)
Terminal/Radius Cap Orientation
Parallel Terminals
Terminal/Radius Cap Orientation
Opposed Terminals
Standard Mounting Bracket Guide: Hermetic Thermostats Only
3100/3106/3150/3156/3305/3306 Series
B-208
B-210
B-209
Top Mounted (Excluding 3150/
3156/3305 Series)
B-212
B-213
B-214
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
51
1/10/2006, 3:46 PM
51
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Hermetic Thermostats Only (continued)
Top or Bottom Mounted
3305 Series Only
B-216
B-215
Notes: 1. Top mounted (excluding Series 3150/3156/3305).
2. Bracket thickness 0,51 ±0,10 [0.020 ±0.004] unless
specified.
3. Decimal tolerance ±0,25 [±0.010] unless specified.
Hermetic Studs/Hex. Studs
(Excluding Series 3305/3306)
Studs
Top Mounted (Excluding 3150/
3156/3305 Series)
B-245
Note: Bracket thickness 0,51 ±0,10 [0.015 ±0.004] unless specified.
3305/3306 Studs
Note: Decimal tolerance ±0,25 [±0.010] unless specified.
52
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
52
1/10/2006, 3:46 PM
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Hermetic Thermostats Only (continued)
Hermetic Overmolds (Silicone or Epoxy)
Note: Dimensions apply to the 3100/3106 only.
Terminal/Bracket Orientations
Parallel
Terminals
Opposed
Terminals
Parallel
Terminals
Opposed
Terminals
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
53
1/10/2006, 3:46 PM
53
THERMOSTATS - PRECISION
Standard Terminal Guide: Non-Hermetic Thermostats Only
3001 Series
T-123
T-124
T-125
T-126
T-127
T-128
T-177
Note: Terminal thickness 0,51 [0.020] REF unless specified.
54
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
54
1/10/2006, 3:46 PM
THERMOSTATS - PRECISION
Standard Terminal Guide: Non-Hermetic Thermostats Only (continued)
3004 Series
T-123
T-124
T-125
T-126
T-127
T-128
T-177
Note: Terminal thickness 0,51 [0.020] REF unless specified.
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
55
1/10/2006, 3:46 PM
55
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Non-Hermetic Thermostats Only
Series 3450/3450CM/3450RC/3455R/3455RC/3455RM/3455RBV
3450, 3450RC
3450CM
3455R, 3455RC
3455RM
3455RBV
56
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
56
1/10/2006, 3:46 PM
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Non-Hermetic Thermostats Only (continued)
Series 3450/3455R/3455RBV/3450C/3455RC/3455RM/3450CM
T-101
T-106
T-107
T-140
T-141
T-146
T-147
T-148
T-149
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
57
1/10/2006, 3:46 PM
57
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Non-Hermetic Thermostats Only (continued)
Standard Terminals - Series 3450/3455R/3455RBV/3450C/3455RC/3455RM/3450CM
T-150
T-151
T-161
T-168
T-169
T-188
58
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
58
1/10/2006, 3:46 PM
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Non-Hermetic Thermostats Only (continued)
Standard Mounting Brackets and Studs - Series 3001/3004 Only
B-201
B-206
B-209
B-210
B-212*
B-213
Notes: 1. Bracket thickness 0,51 ±0,10 [0.020 ±0.004] unless
specified.
2. Decimal tolerance ±0,25 [0.010] unless specified.
Note: Bracket thickness 0,38 ±0,10 [0.015 ±0.004] unless
specified.
Non-Hermetic Studs/Hex. Studs
Non-Hermetic Radius Caps
Note: Bracket thickness ±0,25 [0.010] unless specified.
Note: Bracket thickness ±0,25 [0.010] unless specified.
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
59
1/10/2006, 3:46 PM
59
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Non-Hermetic Thermostats Only (continued)
Series 3450/3455R/3455RBV/3450C/3455RC/3455RM/3450CM
B-201
B-203
B-205
B-203S
B-206
B-207
B-209
B-210
B-212
B-213
60
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
60
1/10/2006, 3:46 PM
THERMOSTATS - PRECISION
Standard Mounting Bracket Guide: Non-Hermetic Thermostats Only (continued)
B-230
B-239
B-241
B-246
B-249
B-250
B-220/B227 Brass Hex Mounting Stud
B-240 Brass Mounting Stud
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
61
1/10/2006, 3:46 PM
61
THERMOSTATS - PRECISION
High Amperage Custom Package Thermostats: Non-Hermetic Internal Thermostats Only
3000-59
3000-105
3000-53
These custom designed Series 3000 packages include a nonhermetic non-adjustable, snap action 3450RC/3455RC
thermostat. Performance characteristics are outlined elsewhere
in this catalog. Housing material varies with customer
requirements. Brass, stainless steel, and other materials are
available. Customized wire, terminals and size may be designed
to suit requirements.
Terminal/Bracket Orientations (Intermediate angles available on special request.)
62
Glo_Comm_minicat_Iss3_FINAL .PMD
www.honeywell.com/sensing
62
1/10/2006, 3:46 PM
THERMOSTATS - HIGH RELIABILITY
High Reliability thermostats are manufactured to meet the stringent
requirements of the military and aerospace industries for dielectric
strength, moisture resistance, vibration, shock and hermetic seal. They
meet all domestic and international approvals, as well as appropriate
military specifications (i.e., MIL-S-24236).
NOTE: The products in this section do not follow the “how to use this
catalogue” instructions provided in the catalogue introduction. Specific
reference numbers are not given due to their custom nature. Please
contact your local Honeywell sales office for ordering information.
3200 Series Aerospace
3MS1 QPL Series Military
The 3200 Series is a single pole, single throw switch activated by a snapaction bimetal disc. Temperature calibrations are pre-set at the factory
and each unit is 100 % thermally and mechanically inspected. It is
available to open or close on temperature rise. The case is laser welded
to form a hermetically sealed steel housing, with a glass-to-metal seal at
the terminal junction. It is manufactured and tested to meet or exceed
critical military and aerospace specifications for spaceflight use, including
temperature stability, shock, vibration and cleanliness.
The 3MS1 Series is a single pole, single throw switch activated by a
snap-action bimetal disc. Temperature calibrations are pre-set at the
factory, and each unit is 100 % thermally and mechanically inspected. It
is available to open or close on temperature rise. The case is laser welded
to form a hermetically sealed steel housing with a glass-to-metal seal at
the terminal junction. It is qualified to MIL-S-24236 and is QPL listed for
military applications.
Amperage:
Housing material:
5 A resistive
Steel housing with glass-to-metal
seal at terminal junction
Operating temperature range:
-51 °C to 163 °C [-60 °F to 325 °F]
Environmental exposure range:
-65 °C to 177 °C [-85 °F to 350 °F]
Dielectric strength:
MIL-STD-202, Method 301, 1250 Vac
Insulation resistance:
MIL-STD-202, Method 302, 500 MOhm
Contact resistance:
MIL-STD-202, Method 307, 0.025 Ohm max.
Hermetic seal:
MIL-STD-202, Method 112, Cond. C
Moisture resistance:
MIL-STD-202, Method 106
Shock:
MIL-STD-202, Method 213, 750 G
Vibration:
MIL-STD-202, Method 204, 30 G
MIL-STD-202, Method 214, 50 G
Acceleration:
MIL-STD-202, Method 212, 20 G
Thermal shock:
MIL-STD-202, Method 107, Cond. B
Salt (1) spray:
MIL-STD-202, Method 101, Cond. B
Amperage:
Housing Material:
5 A resistive
Steel housing with glass-to-metal
seal at terminal junction
Operating temperature range:
-46 °C to 190 °C [-50 °F to 375 °F]
Environmental exposure range:
-65 °C to 260 °C [-85 °F to 500 °F]
Dielectric strength:
MIL-STD-202, Method 301, 1250 Vac
Insulation resistance:
MIL-STD-202, Method 302, 500 MOhm
Contact resistance:
MIL-STD-202, Method 307, 0.050 Ohm max.
Hermetic seal:
MIL-STD-202, Method 112 Cond. C
Moisture resistance:
MIL-STD-202, Method 106
Shock:
MIL-STD-202, Method 213, 100 G
Vibration:
MIL-STD-202, Method 204, 20 G
Acceleration:
MIL-STD-202, Method 212, 20 G
Thermal shock:
MIL-STD-202, Method 107, Cond. B
Salt (1) spray:
MIL-STD-202, Method 101, Cond. B
SERIES NAME
3MS1 QPL Series Military
SERIES NAME
3200 Series Aerospace
www.honeywell.com/sensing
Glo_Comm_minicat_Iss3_FINAL .PMD
63
1/10/2006, 3:46 PM
63
THERMOSTATS - HIGH RELIABILITY
3500 Series Military
3153 Series Low Silhouette
The 3500 Series is a single pole, single throw switch activated by a snapaction bimetal disc. Temperature calibrations are pre-set at the factory,
and each unit is 100 % thermally and mechanically inspected. It is
available to open or close on temperature rise. The case is laser welded
to form a hermetically sealed steel housing, with a glass-to-metal seal at
the terminal junction. It meets or exceeds the requirements of MIL-S24236 and is designed specifically for military and commercial aircraft
applications. It is not QPL listed (see 3MS1).
The 3153 Series is a single pole, single throw switch activated by a snapaction bimetal disc. Temperature calibrations are pre-set at the factory,
and each unit is 100 % thermally and mechanically inspected. It is
available to open or close on temperature rise. The case is laser welded
to form a hermetically sealed steel housing, with a glass-to-metal seal at
the terminal junction. The low silhouette and compact design often make
it especially well-suited for applications that require miniaturization.
Acceptance testing is performed in accordance with MIL-S-24236,
Table III.
Amperage:
Housing material:
5 A resistive
Steel housing with glass-to-metal
seal at terminal junction
Operating temperature range:
-51 °C to 204 °C [-60 °F to 400 °F]
Environmental exposure range:
-65 °C to 260 °C [-85 °F to 500 °F]
Dielectric strength:
MIL-STD-202, Method 301, 1250 Vac
Insulation resistance:
MIL-STD-202, Method 302, 500 MOhm
Contact resistance:
MIL-STD-202, Method 307, 0.050 Ohm max.
Hermetic seal:
MIL-STD-202, Method 112, Cond. C
Moisture resistance:
MIL-STD-202, Method 106
Shock:
MIL-STD-202, Method 213, 400 G
Vibration:
MIL-STD-202, Method 204, 20 G
Acceleration:
MIL-STD-202, Method 212, 20 G
Thermal shock:
MIL-STD-202, Method 107, Cond. B
Salt (1) spray:
MIL-STD-202, Method 101, Cond. B
SERIES NAME
3500 Series Military
6 A resistive
Steel housing with glass-to-metal
seal at terminal junction
Operating temperature range:
-29 °C to 177 °C [-20 °F to 350 °F]
Environmental exposure range:
-65 °C to 260 °C [-85 °F to 500 °F]
Dielectric strength:
MIL-STD-202, Method 301, 1250 Vac
Insulation resistance:
MIL-STD-202, Method 302, 500 MOhm
Contact resistance:
MIL-STD-202, Method 307, 0.050 Ohm max.
Hermetic seal:
MIL-STD-202, Method 112, Cond. C
Moisture resistance:
MIL-STD-202, Method 106
Shock:
MIL-STD-202, Method 213, 100 G
Vibration:
MIL-STD-202, Method 204, 20 G
Thermal shock:
MIL-STD-202, Method 107, Cond. B
Salt (1) spray:
MIL-STD-202, Method 101, Cond. B
SERIES NAME
3153 Series Low Silhouette
64
Glo_Comm_minicat_Iss3_FINAL .PMD
Amperage:
Housing Material:
www.honeywell.com/sensing
64
1/10/2006, 3:47 PM
COMBI-SENSOR
Combi-sensor
The Combi-sensor is a liquid pressure/temperature sensor that uses
piezoresistive and thermistor sensing technology to measure water
pressure and temperature. It is designed for use in boiler system water
pressure and inflow temperature measurement applications.
39,0
[1.54]
Pressure range:
0 bar to 3.0 bar relative
Accuracy:
±2 % over full range
Response time: