0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
82401-56

82401-56

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    -

  • 描述:

    Time Counter (Hour Meter) Panel Mount

  • 数据手册
  • 价格&库存
82401-56 数据手册
Switches and Custom Controls SENSING AND CONTROL Product Catalog ! WARNING IMPROPER INSTALLAION • Consult with local safety agencies and their requirements when designing a machine-control link, interface and all control elements that affect safety. • Strictly adhere to all installation instructions. Failure to comply with these instructions could result in death or serious injury. ! WARNING PERSONAL INJURY • DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. ! WARNING MISUSE OF DOCUMENTATION • The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. • Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. CONTENTS Introduction - How to use this catalogue ..................................................... Page 2 Industrial Electromechanical Limit Switches ................................................ Page 5 Selection Guide .............................................................. Page 6 Limit Switch Application Information .................................... Page 8 Global Limit Switches .................................................... Page 10 Compact Limit Switches ................................................. Page 21 Precision Limit Switches ................................................. Page 34 Heavy Duty Limit Switches ............................................... Page 46 Hazardous Location Switches ........................................... Page 57 Levers for Limit Switches ................................................ Page 71 Power Relays .................................................................................... Page 74 Electromechanical Safety Switches .......................................................... Page 79 Selection Guide ............................................................ Page 80 Basic Switches ................................................................................. Page 103 Pressure Switches ............................................................................. Page 113 Environment Sealed, Hermetically Sealed and Manual Switches .................... Page 119 Sealed Switches .......................................................... Page 119 Manual Switches ......................................................... Page 139 Manual Switches and Pushbuttons ........................................................ Page 165 Selection Guide ........................................................... Page 166 AML Series Advanced Manual Line Switches ........................ Page 168 MML Series Miniature Manual LIne Switches ....................... Page 171 Custom Switches and Assemblies .......................................................... Page 173 Vehicle Controls ............................................................................... Page 175 Custom Controls ........................................................... Page Hour Meters ................................................................ Page Key Switches .............................................................. Page Push/Pull Switches ....................................................... Page Shifters ..................................................................... Page Proportional Retarders ................................................... Page Turn Signals ............................................................... Page Lighting Products ......................................................... Page Other Vehicle Controls ................................................... Page 175 176 184 185 186 187 188 189 194 Precision Aerospace .......................................................................... Page 195 Sensing and Control Product Overview .................................................... Page 196 New Technologies and Emerging Capabilities ........................................... Page 198 Index ............................................................................................ Page 199 Sales and Service ............................................................................. Page 210 www.honeywell.com/sensing 1 INTRODUCTION HONEYWELL SWITCHES AND CONTROLS Honeywell switches and controls provide a wide selection of solutions. This catalogue contains our most popular offerings. To view our complete range of products, visit our web site at http://www.honeywell.com/sensing. Honeywell is a worldwide leader in advanced switching and sensing technology. Our reputation for technology, quality and reliability is second to none. We have more than 60 years of experience; and extensive knowledge of a wide range of industries and an extensive customer service and support network. Honeywell manufactures the original MICRO SWITCH brand switches: micro switches, toggle and rocker switches, hermetically and environmentally sealed switches, and relays and limit switches. Honeywell switches are aimed at providing an enhanced level of performance and quality. vehicular lighting, shifters, pressure and vacuum switches, and custom product development and rapid prototyping technology. Honeywell’s aerospace switches and controls are designed for the most stringent industry requirements. The portfolio consists of position, force, torque and pressure sensors, indicators and actuators. In addition to our standard product offering, Honeywell offers repair and overall services for highly engineered aerospace controls. Honeywell continues to strive to solve customers’ needs. Whether you need custom solutions or standard off-the-shelf products, our extensive in-house design, manufacturing and environmental testing capabilities offer solutions and alternatives to meet your needs. Honeywell HOBBS brand is well known worldwide for the development of quality electromechanical products. The HOBBS brand includes hour meters and battery discharge indicators, key switches, off-highway 2 www.honeywell.com/sensing INTRODUCTION How to use this catalogue For each referenced listing, key specification parameters, descriptions and mounting drawing information are presented. These illustrate our capabilities while the specifications allow easy differentiation between similar products. There are, of course, many more product options available. Full product specification may be accessed on our website (www.honeywell.com/ sensing). At the Home page enter the catalog listing in the SEARCH box and click GO! This will take you directly to the interactive catalogue/ specification search tables for this listing. Alternatively select and click the interactive catalogue icon on the Home page and then choose a product category against which to do a specification search. Also on the website you can access installation instructions, application notes, Frequently Asked Questions (FAQs), selection guides and additional technical information. Mounting dimensions Mounting dimensions shown in each product section are for reference only. For exact information, request an engineering drawing from your nearest Honeywell sales office or visit our website and access it through the interactive catalogue. Where dual dimensions are shown on mounting drawings, the first or upper one is millimetres (mm) and the second or lower is inches (in). Where single dimensions are shown, they are millimetres (mm), unless otherwise stated. To order these products Simply contact your local Honeywell Sales Representative, your Honeywell Distributor or your local Honeywell office. If you need a product not listed in this catalogue One of Honeywell’s strengths is in packaging of sensing technology to meet customer needs. Honeywell provides many variations of our basic switches and sensors. For more information, either browse the full interactive catalogue available on our website, or telephone the following numbers: USA 1-800-537-6945/1-815-537-6945 UK +44 (0)1698 481 481 Germany +49 69 8064 444 France +33 1 60 19 80 40 Italy +39 02 92146 450/456 More information on Honeywell Sensing & Control products and how to contact us can be found on our website. Select the right product – select the right supplier Delivering excellence in system critical sensing solutions A system is critical if the quality, reliability, delivery and customer service associated with a component part is essential to the performance of the operation or end product. If a sensor or a switch is critical to the performance, cost effectiveness, delivery or safety of a product or operation then it’s system critical. It is therefore a defining element in the performance of the system under whatever conditions apply. Failure of the component - or failure of delivery of the component - results in lost productivity, increased costs or a catastrophic event such as a shutdown. Therefore selecting the right product is essential. It can make the difference between success and failure. Honeywell Sensing and Control – delivering excellence To select the right product, first select the right supplier. To deliver the right products for our customers’ needs we listen to them to understand their needs. Using techniques such as “Voice of the Customer and “Concept Engineering” we make sure that the products and solutions we deliver are the right ones. As part of Honeywell we can use local knowledge and understanding combined with global expertise and resources to achieve this. We can deploy many key technologies to bring innovative solutions to customers’ problems. Our products are manufactured to work well and to last. We use Six Sigma Plus productivity to ensure this is the case. We have award winning manufacturing facilities around the world and recognised world class business excellence in manufacturing and supply chain management to deliver on time, anywhere in the world. Our e-business approach offers instant access to product information, technical support and application knowledge through out Internet site. Check out our powerful interactive catalogue that can search and find the right products for customers’ needs and deliver a drawing ready for incorporation in a CAD system direct to your desk. And of course, we manage our whole business for the benefit of our customers, using an acknowledged world-class business excellence approach that incorporates Six Sigma principles. Expanded Product Lines As well as many new and innovative switches, this catalogue includes an expanded range of Pressure and Position Sensors, previously known under the Clarostat, NEI and Electrocorporation brand names. www.honeywell.com/sensing 3 4 www.honeywell.com/sensing LIMIT SWITCHES Industrial Electromechanical Limit Switches Honeywell offers an advanced line of heavy duty limit switches and a wide selection of application-proven enclosed switches (precision snap-acting switches sealed in rugged metal housing). Sealed versions keep out moisture and other contaminants. Our products meet or exceed critical standards allowing for global use. Our rugged switches are suitable for use in harsh-duty, wash-down environments. We offer a variety of circuitry, terminations and actuators to ensure that you can match your choice of switch to your application. Limit and enclosed switches are the cost effective switches of choice for detecting objects which can be touched. When an object comes in contact with an actuator, the switch operates. Rugged and dependable, these switches are offered in a variety of sizes, with different seals, enclosures, actuation, circuitries and electrical ratings. Enclosed switches are known for enhanced precision and low cost. Limit Switches are especially rugged and well sealed. Explosion proof switches are designed for use in hazardous locations. The Honeywell switches featured here are all proven in a broad range of potential Industrial applications - machine tools, packaging machinery, lifting gear, presses and construction machinery. More information about our complete product range - and the depth of product available within each product line - can be found on our interactive catalogue at www.honeywell.com/sensing. MICRO SWITCH Brand products Honeywell has been at the forefront of switching technology since we were the first to develop the precision snap-action switch more than 60 years ago. Ever since we introduced the Micro Switch Brand Products in 1937, we have been recognized as the performance standard that all other switches are measured against. We continue in that tradition by constantly improving the technology, cost-effectiveness, and delivery of these hardworking, versatile electromechanical switches. ! WARNING IF USED IN APPLICATIONS CONCERNING HUMAN SAFETY • Only use NC direct opening (“positive opening”/ “positive break”) contacts, identified by the symbol . • Do NOT use flexible / adjustable actuators. Only use actuators designed for safety applications. • Do NOT defeat, tamper, remove, or bypass this switch. • Hazardous voltage, disconnect power before servicing. • Strictly adhere to all installation and maintenance instructions. • Consult with local safety agencies and their requirements when designing a machine-control link, interface and all control elements that affect safety. Failure to comply with these instructions could result in death or serious injury. www.honeywell.com/sensing 5 LIMIT SWITCHES Selection Guide for Limit Switches Sealing 62,0 x 30,5 x 31,0 [2.44 x 1.20 x 1.22] 66, 67 1, 12, 13 95,3 x 28,7 x 22,0 [3.75 x 1.13 x 0.87] 64 – 96,0 x 28,0 x 39,0 [3.8 x 1.10 x 1.51] 67 1, 4, 12, 13 102,9 x 42,0 x 42,0 [4.05 x 1.65 x 1.65] AC15 A600 (A300 DPDT) DC13 66 GLC/E 1, 4, 12, 13 GLD 1, 2, 12 77,0 x 30,0 x 30,5 [3.03 x 1.18 x 1.20] AC15 A600 Plastic, A300 Metal Housing DC13 67 3, 4, 13 28.4 x 44.2 x 18,0 [1.12 x 1.74 x 0.71] 5 A - 125, 250 Vac 66, 67, 68 1, 2, 3, 3R, 4, 6, 6P, 12 (boot seal), 13 44,0 x 40,0 x 16,0 [1.73 x 1.57 x 0.63] 5 A - 125, 250 Vac 49,0 x 40,0 x 16,0 [1.93 x 1.57 x 0.63] 10 A - 250 Vac CCC 1, 12, 13 UL 65 GLOBAL CSA Height x Width x Depth mm [in] Metal CE NEMA (USA) Plastic C-UL IEC IP GLL Electrical Rating EVN2000 Dimensions EN50041 (GLA) Approvals EN50047 (GLC/D/E) Housing Material DC AC Series EVN2000 GLC GL Global SZL-VL SZL-VL SL1 GLD 914CE Compact 66 (standard), 67 (boot seal) 1, 3, 4, 6, 13 (½ in conduit) 94,0 x 40,6 x 58,42 [3.7 x 1.6 x 2.3] 10 A - 120, 240, 480 Vac BF 67 1, 3, 4, 13 44,5 x 73,5 x 30,2 [1.75 x 2.9 x 1.19] 11 A - 125 Vac, 5 A - 125 Vac BZE/DTE – 1 (E6) 1, 3 (V6) 44,4 x 77,2 x 25,4 [1.75 x 3.04 x 1.0] 1 A - 125 Vac, 15 A - 125 Vac E7 50 (standard), 65 (boot seal) – 45,2 x 76,4 x 25,4 [1.67 x 3.0 x 1.0] 1 A - 125 Vac, 15 A - 125 Vac BAF/DTF – 1, 3, 4, 13; 1 (-2RQ9) 54,8 x 101,6 x 33,0 [2.16 x 4.0 x 1.3] 10 A - 125 Vac, 20 A - 125 Vac HDLS – 1, 3, 4, 4X, 6, 6P, 12, 13 HDLS Fully potted – 1, 4, 6, 6P, 12, 13 (connector) 1, 4, 6, 6P, 12 (cable) – 1, 3, 3R, 4, 4X, 6, 6P, 12, 13 123,0 x 47,7 x 61,9 [4.9 x 1.9 x 2.4] 14CE100 65 (standard), 67 (boot seal) 1, 3 (standard), 1, 3, 4, 12, 13 (boot seal) 49,0 x 40,0 x 16.0 [1.93 x 1.57 x 0.63] AC14 D300, DC13 R300 66/67 – 60,0 x 52,0 x 25,0 [2,36 x 2.05 x 1.0] AC15, DC13 – 1, 7, 9 65,0 x 93,0 x 52,0 [2.56 x 3.66 x 2.0] Up to 20 A @ 125, 250 or 480 Vac – 1, 3, 4, 4X, 6, 6P, 7, 9, 13 102,0 x 102,0 x 145,0 [4.0 x 4.0 x 5.71] Up to 20 A @ 125, 250 or 480 Vac – 1, 3, 4, 6, 7, 9, 13 121,0 x 76,0 x 73,0 [[4.8 x 3.0 x 3.0] SPDT (NEMA A600), DPDT (NEMA B600) LS 67 (20 mm conduit) GXE BZE/ DTE E7 GXE HDLS Stainless steel 14CE100 Heavy Duty HAZARDOUS LOCATION BX CX Hazardous Location EX (-L) (-L) Stainless Steel 67 LSX/BX 6 5 A Resistive - 0.4 A Resistive 125, 250 Vac 125 Vdc EX Precision BAF/ DTF DC13, Q300 CX BF – AC15, A300 LSX 924CE PRECISION 24CE GLE GLA Thermoplastic/ Metal 14CE GLA Die cast base/ Plastic cover 10 A Thermal, 10 A Thermal, 300 Vac 250 Vdc www.honeywell.com/sensing 1, 3, 4, 6, 7, 9, 13 SDPT: 106,7 x 41,1 x 62,0 [4.2 x 1.6 x 2.4] DPDT: 119,1 x 47,8 x 62,0 [4.7 x 1.9 x 2.4] 10 A Thermal: SPDT (NEMA A600), DPDT (NEMA B600) LIMIT SWITCHES Switching Options* Operating Temperature Termination Special Features Slow Action To °C [°F] Snap Action 1NC/ 2NC/ 1NC/ 2NC/ 1NC 1NO 2NO 1NO 2NO -10 [14] 80 [176] -25 [-13] 85 [185] -20 [-4] 60 [140] -25 [-13] 85 [185] 2NC Make Before Break Break Before Make 1NC/ 1NO 1NC/ 2NC/ 2NC/ 3NC/ 4NC 1NO 1NO 2NO 1NO Gold Contacts (Low Energy Options) Page Number From Lowest cost switch option 20 Cable gland/ cord grip Insulation Displacement Termination 10 Flexible cable gland/cord grip Gold plated silver contacts standard 11 Conduit Wide variety of actuator styles and circuitry options Conduit COMPACT SL1 14 14/914CE -40 [-40] 85 [185] -10 [-14] 70 [160] 0 [32]; low temp option to -30° 70 [221] 0 [32] 70 [221] -29 [-20] 71 [160] Conduit -32 [-25] 71 [160] Conduit Cost effective solution 34 -32 [-25] 71 [160] Conduit Precise operation. Low temperature versions available 36 -30 [-22] 70 [158] Conduit Precise operation 41 -32 [-25] 71 [160] Conduit Rugged housed precise operation 42 46 105 [221] 16 Cord grip Miniature size 21 Cable, Quick Connect Low and high temperature options available. Superior Sealing (IP 68) 23 Cable, Quick Connect Low and high temperature options available. Direct acting contacts 26 24/924CE 29 -12 [-10]; -40 [-40] 121 [250]** Conduit Low temperature and Fluorocarbon Seal versions available. Wide variety of actuator styles. Cable and connector available. -12 [-10] Connector 121 [250]; Cable version 105 [221] Cable or Connector Switch cavity is epoxy filled 53 HEAVY DUTY HDLS -12 [-10] -40 [-40] 121 [250]** Conduit, Cable Corrosion resistant stainless steel housing 55 0 [32] 70 [158] Preleaded cable Miniature size 58 -20 [-4] 75 [167] Preleaded cable -40 [-40] 71 [160] Conduit High temperature option (400 °F for 100 Hr) 60 85 [185] Conduit Optional 4-20 mA analog output 64 Conduit Wide variety of actuators, circuitry and termination options 66 Conduit ATEX approvals for European use 66 See Catalog for details See Catalog See Catalog for details for details -40 [-40] See Catalog for details **Refer to catalog for additional data LS 59 Stainless Steel HDLS *HDLS, LSX and BX Series are available with the following Switching Options: NC/NO snap-action, Maintained; 2NC/2NO snap-action, Maintained; 2NC/2NO snap-action, Center Neutral; 2NC/2NO snap-action, Sequential CX, LSX, BX also available with 1NC Direct Acting www.honeywell.com/sensing 7 LIMIT SWITCHES Proper application of limit switches The following are guidelines for the correct application of Limit Switches. Never use the Limit Switch as a physical end stop. Mechanical damage or incorrect operation may occur if this is done. Always ensure that the mechanical actuator is protected from excessive mechanical shock. Never release the actuator suddenly - gradual actuation and release will ensure that stress on the mechanics of the switch is kept to a minimum. This has the added benefit that the switch life will be improved. The diagrams illustrate how to actuate your limit switch for optimum performance. Standards and Electrical rating IEC/EN 60947-1 explains the general rules relating to Low Voltage switchgear and controlgear. The purpose of this standard is to harmonize as much as possible the product performance and test requirements for equipment where the rated voltage does not exceed 1,000 Vac or 1,500 Vdc. WRONG WRONG RIGHT FIXED STOP RIGHT For limit switches with pushrod actuators, the actuating force should be applied as nearly as possible in line with the pushrod axis. WRONG IEC 60947-5-1 is part 5 of the general rules which relates to Controlcircuit devices and switching elements, where rated voltage does not exceed 1,000 Vac or 600 Vdc. There are special requirements for control switches with direct opening operation. These switches are marked on the outside with this symbol: WRONG over-riding cam RIGHT RIGHT over-riding cam The Contact Element form defines the configuration and number of contacts within the switch. Cam or dog arrangements should be such that the actuator is not suddently released to snap back freely. Form Za – both contact elements have the same polarity free position Form Zb – the two contact elements are electrically separated. interference The Utilization Category defines the type of current carried – ac or dc – and the typical application where the switch is used. WRONG The contact rating Designation relates to the Utilization Categories and defines the conventional thermal current Ith (a) rated operational current Ie (A) at rated operational voltages Ue and the VA rating. free position operated position end of overtravel RIGHT Actuators A range of actuators is available for limit switches. Illustrations of actuator types available from this catalogue are shown at the beginning of each product family. Other actuators may be available - for more information please contact your local Honeywell office. Roller lever Top roller lever Adjustable roller lever Top pin plunger Top pin plunger, boot seal end of overtravel WRONG RIGHT Operating mechanisms for limit switches shoud be so designed that, under any operating or emergency conditions, the limit switch is not operated beyond its overtravel limit position. A limit switch should not be used as a mechanical stop. WRONG non-over-riding Top roller plunger Top roller plunger, boot seal Top roller Top roller plunger, plunger, perpendicular perpendicular, boot seal Ball bearing plunger RIGHT over-riding Side pin plunger 8 Side roller plunger Roller lever Yoke lever Rod lever Wobble head For limit switches with lever actuators, the actuating force should be applied as nearly perpendicular to the lever as practical and perpendicular to the shaft axis about which the lever rotates. www.honeywell.com/sensing LIMIT SWITCHES A Note on Degrees of Protection IP Classification NEMA Classification (USA) The IEC 529 standard describes a system for classifying the degree of protection provided by the enclosures of electrical equipment. The level of protection given by the enclosure is indicated by the IP code. This code system uses the letters ‘‘IP’’ (International Protection) followed by up to four digits. Normally only the first two digits are used. IP 1st Digit 2nd Digit 3rd Digit 4th Digit The first digit is numerical and indicates the level of protection within the enclosure against the ingress of solid foreign objects and access to hazardous parts by persons. The second digit is also numerical and indicates the level of protection against the ingress of WATER into the enclosure. NEMA (National Electrical Manufacturer’s Association) prepares standards which define a product, process or procedure with reference to one or more of the following: nomenclature, composition, construction, dimensions, tolerances, safety, operating characteristics, performance, quality, electrical rating, testing and the service for which designed. This standard provides degrees of protection for Enclosures for Electrical Equipment (1000 Volts Maximum) similar to that of the IEC 529 standard. The reference standard herein reflects the latest data in the NEMA Standards Publication when this information went to print. Please check the most current NEMA Standards Publication for the latest information. Non-hazardous locations The third digit is a letter and indicates a higher level of protection for persons against access to hazardous parts. Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment. The fourth digit is also a letter and is used in exceptional cases for supplementary information. Type 3 enclosures are intended for outdoor use primarily to provide a degree of protection against windblown dust, rain, sleet, and external ice formation. If the first or second digit is not required to be specified, then it is replaced by the letter ‘‘X’’ (‘‘XX’’ if both digits are not required). While the tables below serve as a guide to the level of protection, Honeywell recommends that customers refer to the full official IEC specification for the exact definitions. If in doubt about the degree of protection required for a particular application, please consult your local Honeywell office. Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, and hose-directed water. Note: Type 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose-directed water. The IEC 529 standard does not relate to protection against rust, corrosion, icing or corrosive solvents (e.g. cutting fluids) and that product coded IP 67 may not necessarily meet IP 66 requirements. Type 6 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during occasional temporary submersion at a limited depth. First Digit Protection against ingress of solid objects Type 6P enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during prolonged submersion at a limited depth. IP TEST 0 no protection 1 protected against solid objects with a diameter greater than 50 mm 2 protected against solid objects with a diameter greater than 12 mm Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping noncorrosive liquids. 3 protected against solid objects with a diameter greater than 2.5 mm Type 13 enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying water, oil and noncorrosive coolant. 4 protected against solid objects with a diameter greater than 1 mm Note: 5 protected against dust-limited ingress (no harmful deposit) Enclosures are based, in general, on the broad definitions outlined in NEMA Standards. Therefore, it will be necessary to ascertain that a particular enclosure will be adequate when exposed to the specific conditions that might exist in intended applications. 6 totally protected against dust Second Digit Protection against ingress of water IP TEST 0 no protection 1 protected against vertically falling drops of water 2 protected against vertically falling drops of water when the enclosure is tilted at an angle up to 15 degrees 3 protected against water sprayed at an angle of 60 degrees from the vertical 4 protected against splashing water from all directions – limited ingress (no harmful effects) 5 protected against low pressure jets of water from all directions – limited ingress permitted Except as might otherwise be noted, all references to products relative to NEMA enclosure type are based on Honeywell evaluation and Underwriter’s Laboratory (UL) tested. This NEMA Standards Publication does test for environmental conditions such as corrosion, rust, icing, oil, and coolants. The IEC 529 does not, and does not specify degree of protection against mechanical damage of equipment. For this reason, and because the tests and evaluations for other characteristics are not identical, the IEC Enclosure Classification Designations cannot be exactly equated with NEMA Enclosure Type Numbers. 6 protected against powerful jets of water from all directions – limited ingress permitted 7 protected against the effects of temporary immersion in water 8 protected against the effects of continuous immersion in water www.honeywell.com/sensing 9 GLOBAL LIMIT SWITCHES EVN2000 Series EN 50047 Global Limit Switches The EVN2000 series limit switch is an innovative product which has been developed to address a need highlighted by Original Equipment Manufacturers (OEM), where “Ease of Wiring” is required. With the new design there is no need for access to the inside of the housing and therefore the housing cover, cover screws and gasket become obsolete. Furthermore, the integrated cable gland eliminates the need for additional conduit or cable gland hardware. All Normally Closed (NC) contacts are Direct Opening. Mechanical life: Sealing: Operating temperature: Approvals: Housing material: Termination: Switching options: Actuators 10 million IP 66/67, NEMA 1, 12, 13 -25 °C to 85 °C [-13 °F to 185 °F] IEC/EN 60947-5-1 EN 60529 EN81-1 AC15 A300 DC13 Q300 UL, CE Plastic Insulation Displacement Terminals (IDT) Single Pole, Double Throw, Snap action contacts (1NC/1NO) SPDT Operating characteristics Actuator type Operating Free Pretravel Travel to Overtravel Differential Operating torque/force position positive opening travel point (OF) (FP) (PT) (PO) (OT) (DT) (OP) Side rotary EVN2000A 0,120 N m [1.10 lb in] Top pin plunger EVN2000B 16,0 N [3.60 lb] Top roller plunger, parallel 0° 25° 45° 45° 12° 25° 20,0 mm 2,0 mm [0.79 in] [0.08 in] 3,5 mm [0.14 in] 4,0 mm [0.16 in] 1,0 mm [0.04 in] 18,0 mm [0.71 in] 16,0 N [3.60 lb] 30,0 mm 2,0 mm [1.18 in] [0.08 in] 3,5 mm [0.14 in] 4,0 mm [0.16 in] 1,0 mm [0.04 in] 28,0 mm [1.10 in] 16,0 N [3.60 lb] 30,0 mm 2,0 mm [1.18 in] [0.08 in] 3,5 mm [0.14 in] 4,0 mm [0.16 in] 1,0 mm [0.04 in] 28,0 mm [1.10 in] EVN2000C OPTIONS Side rotary plastic roller Top roller plunger, perpendicular EVN2000D Top roller plunger, parallel Top pin plunger CAT. LISTING EVN2000B Top roller plunger, perpendicular CAT. LISTING EVN2000A CAT. LISTING EVN2000C CAT. LISTING EVN2000D 10 www.honeywell.com/sensing GLOBAL LIMIT SWITCHES VL Series General Purpose Compact Limit Switches The new economical SZL-VL Series miniature type limit switches are specially designed for potential applications of small mounting space. These miniature switches are ideal for OEM machinery which requires a rugged and reliable limit switch that is capable of being mounted in space restricted applications. A wide range of actuators and optional neon lamp indicators add additional flexibility. A special pre-molded flexible cable gland allows for fast and simple wiring termination. Mechanical life: Sealing: Operating temperature: Approvals: Termination: Contacts: Electrical ratings: Ampere rating: Switching options: SPDT up to 10 million operations IP 64 -20 °C to 60 °C [-4 °F to 140 °F] UL, C-UL, CE Cable gland Gold plated silver 250 Vac 125 Vdc max. 5 A @ 250 Vac max./0.4 A @ 125 Vdc max. Single Pole, Double Throw, Double break (1NC/1NO) VL 3 4 NO NO 1 2 NC NC Actuators Side rotary actuated switches Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 20° 75° 10° OPTIONS Roller lever Roller lever, adjustable 41.2±.08 18 dia.x7 nylon roller 2 PT 0˚max R3 0 M4 arm fixing nut (Roller can be rotated and locked in any position through 360˚) +0.2 2-4.1 dia. -0 mounting holes +0.008 .161 dia. -0 mounting holes cover screw M3x6 36.2±0.8 Adjustable length of arm (30-70) 0˚max PT 2 1.425±.031 10.2 .402 M4 arm fixing screw (with hexagonal holes) 12.5 .492 56±0.3 2.205±.012 47.7±0.8 1.878±.031 1.622±.031 2-M5 (P=0.8) 18.5 tapped .728 7 .276 in depth mounting holes 20.4±0.3 .803±.012 14 .551 15.1 .594 28 1.102 Operating torque max.: 38.1 1.5 +0.2 2-4.1 0 dia. mounting holes 7.5±0.2 .295±.008 25 .984 (Standard type) 5,88 N [1.32 lb] 10.2 .402 Arm fastening plate 12.5 .492 18.5 .728 Mounting metal M6 arm fastening plate screw with hexagonal holes 56±0.3 2.205±.012 64 2.520 2-M3x23 cover screw 21±0.2 .827±.008 (Roller can be rotated and locked in any position through 360˚) M4 arm fastening plate screw with hexagonal holes +0.008 .161 -0 dia. mounting holes 2-M5 (P=0.8) tapped mounting holes 42.7±0.8 1.681±.031 33.5±0.8 1.319±.031 28.5±0.8 1.122±.031 18 dia.x7 nylon rooler M3x6 cover screw 2-M5 (P=0.8) tapped 7 .276 in depth mounting holes 64 2.520 2.0 .079 2-M3x23 cover screw 2-M5 (P=0.8) tapped mounting holes 14 .551 21±0.2 .827±.008 28 1.102 Operating torque max.: CAT. LISTING SZL-VL-A www.honeywell.com/sensing 7.5±0.2 15.1 .295±.008 .594 20.4±0.3 25 .803±.012 .984 (Standard type) (46.4) (1.827) 3,35 N to 7,84 N [0.75 lb to 1.76 lb] CAT. LISTING SZL-VL-B 11 GLOBAL LIMIT SWITCHES VL Series Side rotary actuated switches (continued) Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Operating force max. (OF): Adjustable rod 5.5 .217 0 PT 2 ˚ max 2.6 .102 dia. rod and locked in any (Roller can be rotated position through 360˚) M4 rod fastening plate screw with hexagonal holes Adjustable lenght of rod (30-118) +0.2 2-4.1 0 dia. mounting holes 44.9 1.768 36.3±0.8 1.429±.031 Top pin plunger 7. 276 dia. stainless steel plunger 18.5 .728 12.5 Rod mounting metal .492 M6 mounting rod fastening screw with hexagonal holes M3x6 cover screw 2-M5 (P=0.8) tapped 7 .276 in depth mounting holes 64 2.520 56±0.3 2.205±.012 2-M5 (P=0.8) tapped mounting holes 2-M3x23 cover screw Operating torque max.: 15.1 .594 25 .984 (44.9) (1.768) 10.2 .402 3 .118 PT 1.5 max +0.2 dia. 2-4.1 0 mounting holes 26.5 1.043 4 .157 +0.008 .161 -0 dia. mounting holes M3x6 cover screw 2-M5 (P=0.8) tapped 7 .276 in depth mounting holes 20.4±0.3 .803±.012 56±0.3 2.205±.012 14 .551 21±0.2 .827±.008 28 1.102 1,5 mm [0.060 in] 4,0 mm [0.158 in] 0,7 mm [0.028 in] 8,83 N [2 lb] 10.2 .402 Rod fastening plate +0.008 .161 -0 dia. mounting holes Plunger actuated switches 64 2.520 7.5±0.2 .295±.008 20.4±0.3 .803±.012 (Standard type) 2-M5 (P=0.8) tapped mounting holes 2-M3x23 cover screw 14 .551 21±0.2 .827±.008 28 1.102 2 N to 7,84 N [0.45 lb to 1.76 lb] 7.5±0.2 15.1 .295±.008 .594 25 .984 (Standard type) CAT. LISTING SZL-VL-C CAT. LISTING SZL-VL-D Top roller plunger 12.5 dia.x3.8 stainless steel roller 10.2 .402 PT 1.5 max 14.8 .583 +0.2 2-4.1 0 dia. mounting holes 38 1.496 4 .157 +0.008 .161 -0 dia. mounting holes M3x6 cover screw 2-M5 (P=0.8) tapped 7 .276 in depth mounting holes 20.4±0.3 .803±.012 56±0.3 2.205±.012 64 2.520 2-M5 (P=0.8) tapped mounting holes 2-M3x23 cover screw 14 .551 21±0.2 .827±.008 28 1.102 15.1 .594 25 .984 7.5±0.2 .295±.008 (Standard type) CAT. LISTING SZL-VL-H 12 www.honeywell.com/sensing GLOBAL LIMIT SWITCHES Plunger actuated switches (continued) Wobble actuated switches Cross roller plunger Pretravel max. (PT): Overtravel min. (OT): Operating force max. (OF): 12.5 dia.x3.8 stainless steel roller 10.2 .402 30 mm [1.18 in] 20 mm [0.788 in] 0,88 N [0.2 lb] Plastic rod, coil spring PT 1.5 max 14.8 .583 +0.2 2-4.1 0 dia. mounting holes +0.008 .161 -0 dia. mounting holes 38 1.496 M3x6 cover screw PT 50 max 4 .157 56±0.3 2.205±.012 5.8 dia. .228 64 2.520 100±1.5 3.937±.059 2-M5 (P=0.8) tapped mounting holes 2-M3x23 cover screw 14 .551 21±0.2 .827±.008 28 1.102 15.1 .594 25 .984 7.5±0.2 .295±.008 (Standard type) CAT. LISTING SZL-VL-E 10.2 .402 41.5 1.634 2-M5 (P=0.8) tapped 7 .276 in depth mounting holes 20.4±0.3 .803±.012 3 dia. .118 Nylon rod +0.2 2-4.1 0 dia. mounting holes +0.008 .161 -0 dia. mounting holes 4 .157 M3x6 cover screw 56±0.3 2.205±.012 2-M5 (P=0.8) tapped 20.4±0.3 .803±.012 7 .276 in depth mounting holes 64 2.520 2-M5 (P=0.8) tapped mounting holes 2-M3x23 cover screw 21±0.2 .827±.008 28 1.102 15.1 .594 25 .984 14 .551 7.5±0.2 .295±.008 (Standard type) CAT. LISTING SZL-VL-F Coil spring SZL-VL-G 10.2 .402 PT 30 max 1.2 dia. .047 stainless steel wire 51.5 2.028 100±1.5 3.937±.059 +0.2 2-4.1 0 dia. mounting holes 4 .157 +0.008 .161 -0 dia. mounting holes M3x6 cover screw 56±0.3 2.205±.012 20.4±0.3 .803±.012 2-M5 (P=0.8) tapped 7 .276 in depth mounting holes 64 2.520 2-M5 (P=0.8) tapped mounting holes 2-M3x23 cover screw 14 .551 21±0.2 .827±.008 28 1.102 15.1 .594 25 .984 7.5±0.2 .295±.008 (Standard type) CAT. LISTING SZL-VL-G www.honeywell.com/sensing 13 GLOBAL LIMIT SWITCHES GLS Series switches offer a complete range of CENELEC approved products, and are suitable for most potential industrial applications. GLS Series Global Limit Switches The standard product EN 50041 norm defines the switch mounting centres as 30 mm x 60 mm and also defines the switching characteristics of the side rotary head with fixed lever, top pin plunger and top roller plunger. This means that the switch can be interchanged in the application with other EN 50041 switches with mounting and switching characteristics maintained. Honeywell offers many more head styles and switching options. The miniature EN 50047 product range offers the user a choice of plastic, metal and three conduit versions which are all mounting (20 mm x 22 mm) compatible with each other. The EN 50047 standard defines how the switches are mounted and the switching characteristics for fixed side rotary lever, top pin plunger and top roller plunger. Electrical ratings Switching options: IEC947-5-1/EN60947-5-1 Designation & SPDT Rated operational current Ie (A) Utilization Category at rated operational voltage Ue 120V 240V 380V 480V 500V 3 1.9 1.5 Single Pole, Double Throw, Snap action contacts (1NC/1NO) VA 14 13 rating 600V Make Break 1.4 1.2 7200 720 AC15 A600 6 AC15 A300 6 3 - - - - 7200 720 AC15 B300 3 1.5 - - - - 3600 360 AC14 D300 0.6 0.3 - - - - 432 72 125V 250V 22 21 DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) DC13 Q300 0.55 0.27 69 69 13 11 23 DC13 R300 0.22 0.1 28 28 21 Vibration (Actuator not fitted): Shock (Actuator not fitted): 10 g conforming to IEC 68-2-6 50 g conforming to IEC 68-2-27 Terminal marking to EN 50013 14 12 24 22 Actuators Operating characteristics Actuator type Body size Operating torque/force (OF) SPDT Lever types A, A*A, A*B, A4J Top pin plunger B Top roller plunger C Top roller lever D Wobble head E7B, E7D, K8B, K8C 14 EN50041 (GLA) DPDT Free position (FP) SPDT DPDT EN50041 (GLA) EN50047 (GLC, GLD, GLE) EN50041 (GLA) EN50047 (GLC, GLD, GLE) EN50041 (GLA) EN50047 (GLC, GLD, GLE) EN50041 (GLA) SPDT DPDT Travel to positive opening (PO) SPDT DPDT 0,330 N m [2.90 lb in] 0,120 N m [1.10 lb in] 16,0 N [3.60 lb] 13,0 N [2.90 lb] GLE only 16,0 N [3.60 lb] 16,0 N [3.60 lb] 13,0 N [2.90 lb] GLE only 9,5 N [2.10 lb] 11,0 N [2.4 lb] 26° 9,0 N [1.9 lb] GLE only SPDT DPDT Differential travel (DT) Operating point (OP) SPDT SPDT DPDT DPDT 12° 55° 0,165 N m [1.50 lb in] GLE only 16,0 N [3.60 lb] Overtravel (OT) 59° 0° EN50047 (GLC, GLD, GLE) Pretravel (PT) 26° 49° 11.5° 8° 37,5 mm [1.48 in] 2,5 mm [0.10 in] 4,5 mm [0.18 in] 4,5 mm [0.18 in] 21,0 mm [0.83 in] 3,0 mm [0.12 in] 5,0 mm [0.20 in] 3,0 mm [0.12 in] 50,5 mm [2.00 in] 2,5 mm [0.10 in] 4,5 mm [0.18 in] 4,5 mm [0.18 in] 31,0 mm [1.22 in] 3,0 mm [0.12 in] 5,0 mm [0.20 in] 3,0 mm [0.12 in] 65,2 mm [2.57 in] 4,2 mm [0.165 in] 8,3 mm [0.33 in] 9,0 mm [0.35 in] 1,7 mm [0.067 in] 61,0 mm [2.40 in] 39,25 mm [1.55 in] 3,45 mm [0.14 in] 6,9 mm [0.27 in] 5,2 mm [0.205 in] 1,3 mm [0.19 in] 35,8 mm [1.41 in] 18° __ __ 8° __ 16° __ __ 0,1 N [0.90 in lb] 35,0 mm [1.38 in] 0,9 mm [0.035 in] 0,9 mm [0.035 in] 0,6 mm [0.024 in] 48,0 mm [1.89 in] 0,9 mm [0.035 in] 0,9 mm [0.035 in] 18,0 mm [0.71 in] 0,6 mm [0.024 in] 28,0 mm [1.10 in] 0° EN50047 (GLC, GLD, GLE) 1,3 N [0.29 lb] 1,1 N [0.25 lb] GLE only www.honeywell.com/sensing 10° 7° __ GLOBAL LIMIT SWITCHES GLA EN 50041 Standard metal body Side rotary adjustable roller Top pin plunger FP Mechanical life: up to 15 million Sealing: IP 67, NEMA 1, 4, 12, 13 Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F] Approvals: IEC/EN 60947-5-1 AC15 A300/A600 DC13 Q300 UL, CSA, CE Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) HEAD OPTIONS Plastic roller CONTACT SPDT DPDT SPDT DPDT SPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm CAT. LISTING GLAA01A2A GLAA20A2A GLAB01A2A GLAB20A2A GLAC01A2A CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm 20 mm CAT. LISTING GLAA01A2B GLAA20A2B GLAB01A2B GLAB20A2B GLAC01A2B GLAC20A2B 37,5 (1.48) CONTACT SPDT DPDT SPDT DPDT SPDT DPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm 20 mm CAT. LISTING GLAA01B GLAA20B GLAB01B GLAB20B GLAC01B GLAC20B Top roller plunger Metal roller CONTACT SPDT DPDT SPDT DPDT SPDT DPDT Side rotary Side rotary adjustable metal rod FP CONTACT SPDT DPDT SPDT DPDT SPDT DPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm 20 mm CAT. LISTING GLAA01C GLAA20C GLAB01C GLAB20C GLAC01C GLAC20C 41 (1.61) 34 (1.34) 4,5 (.17) 75˚ Top roller lever ¯ 3,2 (.13) 13,0 (.51) 32 - 134 75˚ (1.26 - 5,28) No lever Levers: Levers for side rotary types are ordered separately (see pages 71-73 for details) CONTACT SPDT DPDT SPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 CAT. LISTING GLAA01A GLAA20A GLAB01A Plastic roller CONTACT SPDT DPDT SPDT DPDT SPDT DPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm 20 mm CAT. LISTING GLAA01A1A GLAA20A1A GLAB01A1A GLAB20A1A GLAC01A1A GLAC20A1A CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm 20 mm CAT. LISTING GLAA01A1B GLAA20A1B GLAB01A1B GLAB20A1B GLAC01A1B GLAC20A1B Ø 18,7 (.74) 15 (.6) CONTACT SPDT DPDT SPDT DPDT SPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm CAT. LISTING GLAA01A4J GLAA20A4J GLAB01A4J GLAB20A4J GLAC01A4J CONTACT SPDT DPDT SPDT DPDT SPDT DPDT 65,2 (2.51) FP 35,0 (1.38) CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm 20 mm CAT. LISTING GLAA01D GLAA20D GLAB01D GLAB20D GLAC01D GLAC20D Metal roller CONTACT SPDT DPDT SPDT DPDT SPDT DPDT www.honeywell.com/sensing 15 GLOBAL LIMIT SWITCHES GLA EN 50041 Standard metal body (continued) GLC EN 50047 Standard metal body Wobble, coil actuator Wobble, cat whisker 22 (.87) 20 (.78) 24,75 (0.97) 3 (.12) R 2,15 (.08) CONTACT SPDT SPDT DPDT SPDT DPDT CONDUIT ½ in NPT PG 13,5 PG 13,5 20 mm 20 mm 30,5 (1.20) 30 (1.18) CAT. LISTING GLAA01E7B GLAB01E7B GLAB20E7B GLAC01E7B GLAC20E7B 55 (2.16) 3,5 (0.138) 14,5 (.57) 15,25 (.600) Coil wobble head, stainless steel spring actuator conduit thread PG 13,5 CONTACT SPDT SPDT CONDUIT ½ in NPT PG 13,5 CAT. LISTING GLAA01K8B GLAB01K8B Wobble, cat whisker, coil actuator Mechanical life: up to 10 million Sealing: IP 66, NEMA 1, 4, 12, 13 Operating temperature*: -40 °C to 85 °C [-40 °F to 185 °F] Approvals: IEC/EN 60947-5-1 AC15 A300 DC13 Q300 UL, CSA, CE Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) *Wobble actuator rated to -25 °C [-13 °F] HEAD OPTIONS Side rotary ° CONTACT SPDT CONDUIT ½ in NPT CAT. LISTING GLAA01E7D CONTACT SPDT DPDT SPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 CAT. LISTING GLAA01K8C GLAA20K8C GLAB01K8C Plastic roller CONTACT SPDT SPDT CONDUIT ½ in NPT PG 13,5 CAT. LISTING GLCA01A1A GLCB01A1A CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLCA01A1B GLCB01A1B GLCC01A1B Metal roller CONTACT SPDT SPDT SPDT 16 www.honeywell.com/sensing GLOBAL LIMIT SWITCHES GLC EN 50047 Standard metal body (continued) Side rotary adjustable Wobble, coil actuator Top pin plunger Ø 9.9 (.390) DT OP 18±0,5 (.709) CONTACT SPDT SPDT SPDT Plastic roller CONTACT SPDT SPDT CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLCA01B GLCB01B GLCC01B Top roller plunger CONDUIT ½ in NPT PG 13,5 CAT. LISTING GLCA01A2A GLCB01A2A CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLCA01A2B GLCB01A2B GLCC01A2B Mechanical life: 31,0 FP 1.22 Metal roller CONTACT SPDT SPDT SPDT CONTACT SPDT SPDT SPDT CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLCA01C GLCB01C GLCC01C CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLCA01D GLCB01D GLCC01D CONTACT SPDT SPDT SPDT up to 5 million CONDUIT ½ in NPT PG 13.5 20 mm CAT. LISTING GLCA01E7B GLCB01E7B GLCC01E7B Wobble, cat whisker Side rotary adjustable, metal rod Top roller lever 41 (1.61) Ø 34 (1.34) 4,5 (.17) 75˚ FP 39,2 ¯ 3,2 (.13) (1.54) 32 - 134 75˚ (1.26 - 5,28) 15 (.6) CONTACT SPDT SPDT SPDT Mechanical life: CONTACT SPDT SPDT CONDUIT ½ in NPT PG 13,5 CAT. LISTING GLCA01A4J GLCB01A4J CONTACT SPDT SPDT www.honeywell.com/sensing 5 million CONDUIT ½ in NPT PG 13,5 CAT. LISTING GLCA01K8A GLCB01K8A 17 GLOBAL LIMIT SWITCHES GLD EN 50047 Double insulated plastic standard body Side rotary adjustable Plastic roller/metal lever 22 (.87) 20 (.78) 24,75 (0.97) GLE EN 50047 Compatible 3 conduit metal standard body 3 (.12) CONTACT SPDT SPDT R 2,15 (.08) 55 (2.16) 30,5 (1.20) CAT. LISTING GLDA01A2B GLDB01A2B GLDC01A2B Side rotary adjustable metal rod 15,25 (.600) CONTACT SPDT SPDT conduit thread PG 13,5 CONDUIT ½ in NPT PG 13,5 CAT. LISTING GLDA01A4J GLDB01A4J Top pin plunger Mechanical life: See GLC section Sealing: IP 66, NEMA 1, 2, 13 Operating temperature*: -40 °C to 85 °C [-40 °F to 185 °F] Approvals: IEC/EN 60947-5-1 AC15 A600 DC13 Q300 UL, CSA, CE Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) *Wobble actuator rated to -25 °C [-13 °F] See GLC section for dimension illustrations Side rotary Plastic roller/lever CONDUIT ½ in NPT PG 13,5 CAT. LISTING GLDA01A1A GLDB01A1A Metal roller/lever CONDUIT ½ in NPT PG 13,5 20 mm CONTACT SPDT SPDT SPDT CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLDA01B GLDB01B GLDC01B Mechanical life: up to 10 million Sealing: IP 66, NEMA 1, 4, 12, 13 Operating temperature*: -40 °C to 85 °C [-40 °F to 185 °F] Approvals: IEC/EN 60947-5-1 AC15 A300 DC13 Q300 UL, CSA, CE Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) *Wobble actuator rated to -25 °C [-13 °F] Top roller plunger CONTACT SPDT SPDT SPDT CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLDA01C GLDB01C GLDC01C CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLDA01D GLDB01D GLDC01D HEAD OPTIONS Side rotary Top roller lever HEAD OPTIONS CONTACT SPDT SPDT SPDT CONDUIT ½ in NPT PG 13,5 20 mm 3,5 (0.138) 14,5 (.57) CONTACT SPDT SPDT CAT. LISTING GLDA01A2A GLDB01A2A Metal roller/metal lever CONTACT SPDT SPDT SPDT 30 (1.18) CONDUIT ½ in NPT PG 13.5 CONTACT SPDT SPDT SPDT Wobble, coil actuator CONTACT SPDT SPDT SPDT CONDUIT ½ in NPT PG 13,5 20 mm CAT. LISTING GLDA01E7B GLDB01E7B GLDC01E7B CAT. LISTING GLDA01A1B GLDB01A1B GLDC01A1B Plastic roller CONTACT SPDT SPDT DPDT CAT. LISTING GLEA01A1A GLEB01A1A GLEB24A1A CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm CAT. LISTING GLEA01A1B GLEA24A1B GLEB01A1B GLEB24A1B GLEC01A1B Metal roller CONTACT SPDT DPDT SPDT DPDT SPDT 18 CONDUIT ½ in NPT PG 13,5 PG 13,5 www.honeywell.com/sensing GLOBAL LIMIT SWITCHES GLE EN 50047 Compatible 3 conduit metal standard body (continued) Offset side rotary roller Side rotary adjustable metal rod Top roller lever 41 (1.61) FP 39,2 (1.54) 4,5 (.17) 34 (1.34) 75˚ ¯ 3,2 (.13) 32 - 134 75˚ (1.26 - 5,28) Plastic roller CONTACT SPDT SPDT CONDUIT ½ in NPT PG 13,5 15 (.6) CAT. LISTING GLEA01A5A GLEB01A5A CONTACT SPDT DPDT CONDUIT PG 13,5 PG 13,5 CAT. LISTING GLEB01A4J GLEB24A4J Side rotary adjustable CONTACT SPDT DPDT SPDT DPDT SPDT DPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 13,5 20 mm 20 mm CAT. LISTING GLEA01D GLEA24D GLEB01D GLEB24D GLEC01D GLEC24D Wobble, coil actuator Top pin plunger 16˚ ±5˚ (2.37) OP DT 10˚ OT 35˚ (max) 100 (3.92) 18 (0.709) Plastic roller CONTACT SPDT DPDT SPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 CAT. LISTING GLEA01A2A GLEA24A2A GLEB01A2A CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 CAT. LISTING GLEA01B GLEA24B GLEB01B GLEB24B Mechanical life: CONTACT SPDT DPDT SPDT DPDT Top roller plunger Metal roller CONTACT SPDT SPDT DPDT CONTACT SPDT DPDT SPDT DPDT CONDUIT ½ in NPT PG 13,5 PG 13,5 CAT. LISTING GLEA01A2B GLEB01A2B GLEB24A2B Ø 12,4 (0.49) 31,0 FP 1.23 CONTACT SPDT DPDT SPDT DPDT DPDT CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm up to 5 million CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 CAT. LISTING GLEA01E7B GLEA24E7B GLEB01E7B GLEB24E7B CAT. LISTING GLEA01C GLEA24C GLEB01C GLEB24C GLEC24C www.honeywell.com/sensing 19 GLOBAL LIMIT SWITCHES GLL EN50047 Standard plastic body Mechanical life: 5 million Sealing: IP 65, NEMA 1, 12, 13 Operating temperature: -10 °C to 80 °C [14 °F to 176 °F] Approvals: c-UL-US, CE, CCC Switching options: SPDT Single Pole, Double Throw Direct opening snap action contacts (1NC/1NO) Top roller plunger CONDUIT ½ in NPT 20 mm Side rotary, 31,5 mm fixed length lever with 50 mm rubber roller CAT. LISTING GLLA01C GLLC01C Side rotary, 25 mm fixed length with metal roller CONDUIT ½ in NPT 20 mm CAT. LISTING GLLA01A1Y GLLC01A1Y Side rotary, 20 mm to 65 mm adjustable length lever with 50 mm rubber roller Actuators HEAD OPTIONS Top plunger CONDUIT ½ in NPT 20 mm CAT. LISTING GLLA01A1B GLLC01A1B Side rotary, 20 mm to 65 mm adjustable length lever with metal roller CONDUIT 1/2 in NPT 20 mm CONDUIT ½ in NPT 20 mm CAT. LISTING GLLA01B GLLC01B CONDUIT ½ in NPT 20 mm 20 CAT. LISTING GLLA01A2B GLLC01A2B www.honeywell.com/sensing CAT. LISTING GLLA01A2Y GLLC01A2Y COMPACT LIMIT SWITCHES SL1 Series Compact Limit Switches The SL1 Series compact limit switches are sealed, sensitive and have a long life. The compact size makes them suitable for the total miniaturization of machinery or equipment. Mechanical life: Sealing: Operating temperature: Approvals: Termination: Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Electrical rating/contact: 10 million IP 67, NEMA 3, 4, 13 -10 °C to 70 °C [14 °F to 160 °F] UL, CSA, CE Cable gland 11,76 N [2.64 lb] 1,5 mm [0.060 in] 3,0 mm [0.118 in] 0,10 mm [0.004 in] SL1-* 5A - 125, 250 Vac Silver SL1-* K 0.1 A - 125 Vac; 0.1 A - 30 Vdc Gold clad cross point Switching options: SPDT Single Pole, Double Throw, Snap action contacts (1NC/1NO) Actuators OPTIONS Top roller plunger, parallel, boot seal Top pin plunger 11 D X 4W ROLLER PT 25,4 (OP) CONTACT Silver Gold clad cross point CAT. LISTING SL1-H SL1-HK Top roller plunger, parallel CAT. LISTING SL1-B SL1-BK Top roller plunger, long, parallel 41,4 (OP) 31,4 (OP) CONTACT Silver Gold clad cross point CONTACT Silver Gold clad cross point CAT. LISTING SL1-A SL1-AK CONTACT Silver Gold clad cross point www.honeywell.com/sensing CAT. LISTING SL1-E SL1-EK 21 COMPACT LIMIT SWITCHES Top roller plunger, perpendicular Top roller lever 31,4 (OP) CONTACT Silver Gold clad cross point CAT. LISTING SL1-D SL1-DK Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): CONTACT Silver Gold clad cross point Top roller plunger, long, perpendicular 41,4 (OP) CONTACT Silver Gold clad cross point 22 CAT. LISTING SL1-K SL1-KK www.honeywell.com/sensing 3,92 N [0.88 2,0 mm [0.079 4,0 mm [0.158 0,3 mm [0.012 CAT. LISTING SL1-P SL1-PK lb] in] in] in] COMPACT LIMIT SWITCHES 14CE/914CE Series Miniature Enclosed Switches The 14CE/914CE Series offers a miniature, rugged, compact, pre-wired switch which has gained wide market acceptance and performed successfully in a wide range of potential applications. The entire range of 14CE and 914CE switches has been approved to meet the requirements of the Low Voltage directive and is therefore CE marked. CE switches have different degrees of protection from IP66 to IP68 for the fully booted head styles. The cable entry is fully potted using a special compound to ensure that ingress is virtually impossible. Mechanical life: Sealing: Operating temperature: Approvals: Operating force (OF): Pretravel (PT): Overtravel (OT): Differential travel (DT): Contact/Rating: Connection: Actuators Switching options: 10 million IP66, IP67, IP68 NEMA 1, 2, 3, 3R, 4, 6, 6P, 12 (boot seal), 13 14CE 0 °C to 70 °C [32 °F to 158 °F] 914CE 0 °C to 105 °C [32 °F to 221 °F] 14CE CE 914CE CSA, UL, CE AC14 D300 DC13 R300 11,8 N [2,65 lb] max. 1,8 mm [0.71 in] max. 3,0 mm [0.118 in] min. 0,1mm [0.004 in] max. (9)14CE* -* Silver A (9)14CE* -*G Gold B (9)14CE* -Q, -AQ, -AQ1 Silver C Harmonised CENELEC 4 x 0,75 mm2 cable (14CE) SJTO 4 x 0,75 mm2 (18 AWG) cable (914CE) Connector (dc), 4 pin male, M12 thread (-Q) Connector (ac), 4 pin male, ½ in x 20 thread (-Q1) SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) S.P.D.T BROWN 2 914CE 14CE GREEN/YELLOW BLUE 1 3 BLACK Electrical ratings: A UL/CSA: B UL: C UL/CSA: Amps 240 Vac, ind. 240 Vac, res. 28 Vdc, res. 28 Vdc, ind. 5 A, 1/10 Hp, 125 or 250 Vac Make 1.2 5 3 3 Break 0.2 5 3 3 1 A res., 0.5 A ind., 30 Vdc 1 A, 125 Vac 3 A, 125 or 250 Vac Operating point (OP) 1,8 max PT Free position (FP) Ø 14CE 7,4 (0.29) 914CE 8,65 (0.34) www.honeywell.com/sensing 3 min OT , , , Side exit cable (Option 'A') 23 COMPACT LIMIT SWITCHES Plunger actuated switches OPTIONS Top pin plunger Ø 10,0 (0.39) Ball bearing plunger Top roller plunger, parallel Ø 12,4 (0.49) OP 15,7 (0.62) OP 28,4 (1.12) OP 24,4 (0.96) NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 3 ft cable, side exit 3 ft cable, bottom exit, gold contacts 6 ft cable, bottom exit 6 ft cable, bottom exit, gold contacts 9 ft cable, bottom exit Connector (dc), bottom exit Connector (ac), bottom exit CAT. LISTING 914CE1-3 914CE1-3A 914CE1-3G 914CE1-6 914CE1-6G 914CE1-9 914CE1-Q 914CE1-Q1 EUROPE CAT. LISTING 1 metre cable, bottom exit 14CE1-1 1 metre cable, side exit 14CE1-1A 1 metre cable, bottom exit, gold contacts 14CE1-1G 2 metre cable, bottom exit 14CE1-2 3 metre cable, bottom exit 14CE1-3 3 metre cable, side exit 14CE1-3A 3 metre cable, bottom exit, gold contacts 14CE1-3G Connector (dc), side exit 14CE1-AQ Connector (dc), bottom exit 14CE1-Q NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 6 ft cable, bottom exit CAT. LISTING 914CE66-3 914CE66-6 EUROPE/ 1 metre cable, bottom exit 2 metre cable, bottom exit CAT. LISTING 14CE66-1 14CE66-2 Adjustable plunger Top pin plunger, boot seal Ø 7,0 (0.28) OP NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 3 ft cable, side exit 3 ft cable, bottom exit, gold contacts 6 ft cable, bottom exit 6 ft cable, side exit 9 ft cable, bottom exit Connector (dc), side exit Connector (dc), bottom exit Connector (ac), bottom exit CAT. LISTING 914CE2-3 914CE2-3A 914CE2-3G 914CE2-6 914CE2-6A 914CE2-9 914CE2-AQ 914CE2-Q 914CE2-Q1 EUROPE CAT. LISTING 1 metre cable, bottom exit 14CE2-1 1 metre cable, side exit 14CE2-1A 1 metre cable, bottom exit, gold contacts 14CE2-1G 2 metre cable, bottom exit 14CE2-2 2 metre cable, side exit 14CE2-2A 3 metre cable, bottom exit 14CE2-3 3 metre cable, side exit 14CE2-3A 3 metre cable, bottom exit, gold contacts 14CE2-3G Connector (dc), side exit 14CE2-AQ Connector (dc), bottom exit 14CE2-Q Top roller plunger, parallel, boot seal OP 24,6 (0.98) Ø 12,4 (0.49) OP 34,4 (1.35) Operating force (OF): 22,5 N [5.06 lb] NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 3 ft cable, side exit 6 ft cable, bottom exit 9 ft cable, bottom exit 9 ft cable, side exit Connector (ac), side exit Connector (dc), bottom exit Connector (ac), bottom exit CAT. LISTING 914CE18-3 914CE18-3A 914CE18-6 914CE18-9 914CE18-9A 914CE18-AQ1 914CE18-Q 914CE18-Q1 EUROPE 1 metre cable, bottom exit 3 metre cable, bottom exit Connector (dc), bottom exit CAT. LISTING 14CE18-1 14CE18-3 14CE18-Q Top pin plunger, panel mounted M10x1 Thread OP 29,2 (1.15) NORTH AMERICA/GLOBAL Connector (dc), bottom exit 24 NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 9 ft cable, bottom exit CAT. LISTING 914CE19-3 914CE19-9 Manually operated OP 27,4 (1.08) Operating force (OF): 17,5 N [3.82 lb] NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 6 ft cable, bottom exit CAT. LISTING 914CE31-3 914CE31-6 EUROPE 1 metre cable, bottom exit 3 metre cable, bottom exit CAT. LISTING 14CE31-1 14CE31-3 Top roller plunger, parallel, panel mounted Operating force (OF): NORTH AMERICA/GLOBAL 6 ft cable, bottom exit 9,0 N [2.02 lb] CAT. LISTING 914CE22-6 CAT. LISTING 914CE27-Q OP 42,5 (1.67) NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 6 ft cable, bottom exit Connector (dc), bottom exit www.honeywell.com/sensing CAT. LISTING 914CE28-3 914CE28-6 914CE28-Q COMPACT LIMIT SWITCHES 14CE/914CE Series Plunger actuated switches (continued) Side rotary and wobble actuated switches Top roller plunger, perpendicular OPTIONS 5,1 (0.20) Rotary motion Ø 12,4 (0.49) OP 28,5 (1.12) NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 6 ft cable, bottom exit 6 ft cable, side exit 9 ft cable, bottom exit Connector (dc), bottom exit Connector (ac), bottom exit CAT. LISTING 914CE3-3 914CE3-6 914CE3-6A 914CE3-9 914CE3-Q 914CE3-Q1 EUROPE 1 metre cable, bottom exit 2 metre cable, bottom exit 3 metre cable, bottom exit CAT. LISTING 14CE3-1 14CE3-2 14CE3-3 Top roller plunger, perpendicular, boot seal OP 34,4 (1.35) (actuating lever not included - use any LSZ51*, LSZ52*, LSZ54*, LSZ55* or LSZ61* Series shown on pages 71-73) Operating torque: Pretravel (PT): Overtravel (OT) mm: Differential travel: 0,3 Nm [2.66 in lb] 30° max. 40° min. 3° NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 3 ft cable, side exit 6 ft cable, bottom exit 9 ft cable, bottom exit Connector (dc), bottom exit CAT. LISTING 914CE16-3 914CE16-3A 914CE16-6 914CE16-9 914CE16-Q EUROPE 1 metre cable, bottom exit 2 metre cable, bottom exit 3 metre cable, bottom exit CAT. LISTING 14CE16-1 14CE16-2 14CE16-3 Wobble Spring wire Operating force (OF): 17,5 N [3.82 lb] NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 3 ft cable, side exit CAT. LISTING 914CE55-3 914CE55-3A Top roller plunger, perpendicular, panel mounted OP 42,5 (1.67) NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 6 ft cable, bottom exit CAT. LISTING 914CE29-3 914CE29-6 Operating Force (OF): 0,55 N [0.12 lb] NORTH AMERICA/GLOBAL 3 ft cable, bottom exit 6 ft cable, bottom exit 9 ft cable, bottom exit Connector (dc), bottom exit CAT. LISTING 914CE20-3 914CE20-6 914CE20-9 914CE20-Q EUROPE 1 metre cable, bottom exit 3 metre cable, bottom exit CAT. LISTING 14CE20-1 14CE20-3 www.honeywell.com/sensing 25 COMPACT LIMIT SWITCHES 24CE/924CE Series Miniature Safety Electromechanical Switches Actuators For position sensing and switching applications requiring direct acting, positive opening contacts the 24CE and 924CE ranges are ideal. They have been tested and approved to meet the requirements of the Low Voltage directive and positive opening safety contacts per IEC/EN 60947-5-1-3. The devices are CE marked. The red colour clearly differentiates this safety component in the application. The 924CE range also has UL and CSA approval. It is possible for the end user to enhance the safety level of these switches from Category 1 on their own to Categories 2, 3 or 4 when the switches are used in conjunction with our wide range of FF-SR safety relays to form a safety system. Potential applications for these switches could use the roller plunger 24CE2- or 24CE3- style in conjunction with cams on doors with hinges; or our fixed side rotary 24CE16- style for detection of sliding doors. Also available are a range of panel mounting or top mounting versions to ensure that small space or difficult mounting can be simply achieved. Several contact arrangements are available. Mechanical life: 10 million Sealing: standard type: IP66; with boot seal type: IP67 Operating temperature: 24CE 0 °C to 70 °C [32 °F to 158 °F] Low temperature: -40 °C [-40 °F] 924CE 0 °C to 105 °C [32 °F to 221 °F] Approvals: 24CE CE AC15 B300 DC13 R300 924CE CSA, CE per UL file #E41859, 10 A 250 Vac; 1/3 Hp 125-250 Vac AC15 B300 DC13 R300 Connection: Harmonised CENELEC 3 or 5 x 0,75 mm2 cable (24CE) SJTO 3 or 5 x 18 AWG cable (924CE) Contacts: Silver Switching options: 924CE 24CE Slow action contacts (1NC) black red blue brown green green/yellow Slow action contacts (1NC/1NO), Break Before Make (BBM) black red Zb white blue brown green green/yellow Zb white black black Slow action contacts (1NC/1NO), Make Before Break (MBB) black blue red white brown green Zb green/yellow Zb black white Electrical ratings: & Utilization .Designation .... Category AC15 B300 DC13 R300 black IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 3 1.5 125 V 250 V 0,22 0,1 40 / max. 1.58 16 / max. 0.63 25 / 0.98 Free position 2 Holes 5,1 dia Counter Bored 10,2 dia x 6 deep (both sides - option 'A' only) 49 / max. 1.93 8/ 0.32 1NC: 8,4 / .33 1NC/1NO: 9,5 / .374 26 www.honeywell.com/sensing Side exit cable (Option 'A') Note: connector versions also available VA rating Make Break 3600 360 28 28 COMPACT LIMIT SWITCHES 24CE/924CE Series OPTIONS Side rotary OT Top pin plunger, boot sealed PT PT DT DT ø7,1 Top roller plunger, parallel ø12,4 OT 30,3 max. 24,3 max. North America/Global North America/Global CABLE LENGTH CONTACT 6 ft 1NC/1NO, BBM North America/Global CABLE LENGTH 3 ft 9 ft 3 ft 3 ft 9 ft CONTACT 1NC, BBM 1NC, BBM 1NC, MBB 1NC 1NC CAT. LISTING 924CE16-S3 924CE16-S9 924CE16-T3 924CE16-Y3 924CE16-Y9 CONTACT 1NC/1NO, BBM 1NC 1NC CAT. LISTING 24CE16-S1 24CE16-Y1 24CE16-Y6 CAT. LISTING 924CE18-S6 Adjustable plunger Europe CABLE LENGTH 1m 1m 6m OPTION side exit side exit CAT. LISTING 924CE2-S15 924CE2-S21 924CE2-S3 924CE2-S6 924CE2-S6A 924CE2-S9 924CE2-T25 924CE2-T25A 924CE2-T3 924CE2-T6 924CE2-T9 924CE2-Y3 924CE2-Y9 Europe CABLE LENGTH CONTACT 3 ft 1NC/1NO, BBM ø10 CONTACT 1NC, BBM 1NC, BBM 1NC, BBM 1NC, BBM 1NC, BBM 1NC, BBM 1NC, MBB 1NC, MBB 1NC, MBB 1NC, MBB 1NC, MBB 1NC 1NC OP North America/Global Top pin plunger CABLE LENGTH 15 ft 21 ft 3 ft 6 ft 6 ft 9 ft 25 ft 25 ft 3 ft 6 ft 9 ft 3 ft 9 ft OPTION CAT. LISTING low temperature 924CE19-S3L1 17,5 max. CABLE LENGTH 1m 2m 2m 2m 3m 6m 2m 1m 2m 2m 4m 6m CONTACT 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, MBB 1NC 1NC 1NC 1NC 1NC OPTION CAT. LISTING 24CE2-S1 24CE2-S2 side exit 24CE2-S2A low temperature 24CE2-S2B 24CE2-S3 24CE2-S6 24CE2-T2 24CE2-Y1 24CE2-Y2 side exit 24CE2-Y2A 24CE2-Y4 side exit 24CE2-Y6A North America/Global CABLE LENGTH 3 ft 6 ft 9 ft 25 ft 3 ft 3 ft 6 ft 9 ft 9 ft 3 ft 9 ft CONTACT 1NC, BBM 1NC, BBM 1NC, BBM 1NC, MBB 1NC, MBB 1NC, MBB 1NC, MBB 1NC, MBB 1NC, MBB 1NC 1NC OPTION CONTACT 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC 1NC 1NC OPTION CAT. LISTING low temperature 24CE1-S12B 24CE1-S2 side exit 24CE1-S2A low temperature 24CE1-S2B 24CE1-S3 24CE1-S6 side exit 24CE1-Y1A 24CE1-Y2 24CE1-Y3 side exit side exit side exit side exit CAT. LISTING 924CE1-S3 924CE1-S6 924CE1-S9 924CE1-T25A 924CE1-T3 924CE1-T3A 924CE1-T6A 924CE1-T9 924CE1-T9A 924CE1-Y3 924CE1-Y9 Europe CABLE LENGTH 12 m 2m 2m 2m 3m 6m 1m 2m 3m www.honeywell.com/sensing 27 COMPACT LIMIT SWITCHES Top roller plunger, parallel, boot sealed Top roller plunger, perpendicular ø12,4 ø12,4 30,3 max. 36,1 max. North America/Global North America/Global CABLE LENGTH 6 ft 20 ft 3 ft Y3L1 CONTACT 1NC, BBM 1NC 1NC OPTION CAT. LISTING 924CE31-S6 924CE31-Y20 low temperature 924CE31- CABLE LENGTH 3 ft 6 ft 9 ft 9 ft CONTACT 1NC, BBM 1NC, BBM 1NC, BBM 1NC, MBB CAT. LISTING 924CE3-S3 924CE3-S6 924CE3-S9 924CE3-T9 CONTACT 1NC/1NO, BBM 1NC 1NC CAT. LISTING 24CE3-S2 24CE3-Y1 24CE3-Y2 Europe Europe CABLE LENGTH 1m 2m 2m 5m 1m 2m 3m CONTACT 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC/1NO, BBM 1NC 1NC 1NC OPTION CAT. LISTING 24CE31-S1 24CE31-S2 low temperature 24CE31-S2B 24CE31-S5 24CE31-Y1 24CE31-Y2 24CE31-Y3 CABLE LENGTH 2m 1m 2m Top roller plunger, perpendicular, boot sealed ø12,4 Top roller plunger, parallel, panel mounted 36,1 max. 27,7 (1.75) Europe CABLE LENGTH 1m 2m 1m North America/Global CABLE LENGTH CONTACT 15 ft 1NC, BBM CONTACT 1NC/1NO, BBM 1NC/1NO, BBM 1NC CAT. LISTING 24CE55-S1 24CE55-S2 24CE55-Y1 CAT. LISTING 924CE28-S15 Europe CABLE LENGTH CONTACT 2m 1NC/1NO, BBM 28 CAT. LISTING 24CE28-S2 www.honeywell.com/sensing COMPACT LIMIT SWITCHES LS Series Compact Limit Switches LS Series compact limit switches are carefully designed for enhanced repeatability under the most stringent conditions. Compact size and field adjustable features greatly extend the flexibility of these switches. Heads may be positioned at 90° increments. Side rotary models can be adjusted for clockwise and/or counter-clockwise operation. Actuators can be set and locked in any position through 360°. The rugged housings and actuator heads are constructed from cast aluminium, capable of withstanding physical abuse. Protection against oil, water and dust is achieved by O-ring seals on the actuator shaft; a ring seal between head and body; and a seated compression seal between cover and case. The LS fits in many places too small for any other fully adjustable limit switch. Conduit: ½ in - 14 NPT 20 mm NEMA 1, 3, 4, 6, 13 IP67 -29 °C to 71 °C [-20 °F to 160 °F] -29 °C to 121 °C [-20 °F to 250 °F] UL, CSA Silver Cadmium Oxide (1) Fine Silver Single Pole, Double Throw Snap action contacts (1NC/1NO) Sealing: ½ in - 14 NPT conduit 20 mm conduit Operating temperature: Standard High Approvals: LS-L Contacts: Electrical ratings A, B, C, D, E Electrical ratings F, G Switching options: SPDT Actuators Electrical ratings: 4 3 1 2 A 10 A, 120, 240 or 480 Vac; 1/3 hp, 120 Vac; ¾ hp, 240 Vac; 0.8 A, 115 Vdc**; 0.4 A, 230 Vdc;** 0.1 A, 550 Vdc;** Pilot Duty, 600 Vac max. B 10 A, 120, 240 or 480 Vac; ¼ hp, 120 Vac; ½ hp, 240 Vac. Pilot Duty, 600 Vac max. C 10 A, 120 Vac; 1/3 hp, 120 Vac. D 10 A, 120, 240, 480 Vac; ¼ hp, 120 Vac; ½ hp, 240 Vac; 0.8 A, 115 Vdc**; 0.4 A, 230 Vdc**; 0.1 A, 550 Vdc**; Pilot Duty, 600 Vac max. E 10 A, 120, 240 or 480 Vac; 1/3 hp, 120 Vac; ¾ hp, 240 Vac. Pilot Duty, 600 Vac max. F UL Rating: 10 A, 125, 250, or 480 Vac; 1/3 hp, 125 Vac; ¾ hp, 250 Vac; 0.8 A, 125 Vdc**; 0.4 A, 250 Vdc** G UL Rating: 10 A, 125, 250 or 480 Vac; ¼ hp, 125 Vac; ½ hp, 250 Vac; 0.8 A, 125 Vdc**; 0.4 A, 250 Vdc** ** Resistive rating (1) Designed for use with inductive loads such as relays, contactors, motors and solenoids. Honeywell does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. www.honeywell.com/sensing 29 COMPACT LIMIT SWITCHES LS Series Side rotary actuated switches OPTIONS Adjustable roller lever Fixed length lever Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT) Differential travel max. (DT): Switching options: Lever: Standard Low Standard Low 13,3 N [3.0 lb] 5,0 N [18 oz] 20° 5° 30° Standard 12° Low 4° SPDT Aluminium, steel roller Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT) Differential travel max. (DT): 20 mm 20 mm Low PT/OF Low PT Low PT 20 mm High temperature High temperature 20 mm Indicator light Low OF 30 ELECTRICAL RATING A F A B B B A A C A CAT. LISTING 1LS1 1LS1-L 1LS1-4C 1LS131 1LS19 1LS19-4C 1LS243 1LS243-4C 1LS501 1LS6 Standard Low Switching options: Lever: CONDUIT CONDUIT Standard Low Standard Low Low PT Low OF/PT/DT www.honeywell.com/sensing ELECTRICAL RATING A F A B B 13,3 N [3.0 lb] 5,0 N [18 oz] 20° 5° 30° 12° 4° SPDT Aluminium, nylon roller CAT. LISTING 1LS3 1LS3-L 1LS3-4C 1LS58 1LS59 COMPACT LIMIT SWITCHES No lever Note: Levers for are ordered separately (see pages 71-73 for details) Adjustable rod Operating force max. (OF): Pretravel max. (PT): Operating force max. (OF): Standard Low with standard PT Low with low PT Pretravel max. (PT): Standard Low Maintained contact Overtravel min. (OT) Standard Maintained contact Differential travel max. (DT): Standard Low PT Maintained contact Switching options: 0,51 N m [4.5 in lb] 0,21 N m [30 in oz] 0,11 N m [1 in lb] 20° 5° 55° 30° 35° 12° 4° 20° SPDT Maintained contact Overtravel min. (OT) Differential travel max. (DT): Standard Low Standard Low Standard Low Switching options: Lever: CONDUIT 20 mm Low PT Low PT/OF/DT ELECTRICAL RATING A F A B B 1,39 N [5 oz] 0,83 Nm [3 oz] 20° 5° 30° 12° 4° SPDT Aluminium rod CAT. LISTING 1LS10 1LS10-L 1LS10-4C 1LS47 1LS53 SPDT contact CONDUIT 20 mm Low OF Low OF/PT Low PT ELECTRICAL RATING A F A A B B CAT. LISTING 1LS2 1LS2-L 1LS2-4C 1LS23 1LS56 1LS9 Maintained contact CONDUIT ELECTRICAL RATING A F Side rotary, yoke lever, maintained contact Operating force max. (OF): 8,9 N [2.0 lb] Pretravel max. (PT): 55° Switching options: Maintained Lever: 6LS1Steel rollers on opposite sides of arm 6LS3 Nylon rollers on same side of arm CAT. LISTING 6LS2 6LS2-L CONDUIT 20 mm www.honeywell.com/sensing ELECTRICAL RATING A A A CAT. LISTING 6LS1 6LS1-4C 6LS3 31 COMPACT LIMIT SWITCHES LS Series Plunger actuated switches OPTIONS Top pin plunger Side pin plunger Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT) Differential travel max. (DT): Standard Low Standard Low Standard Low Switching options: 31,14 N [7 lb] 10 N [36 oz] 1,65 mm [0.065 in] 6,35 mm [0.25 in] 5,56 mm [0.219 in] 0,51 mm [0.020 in] 0,23 mm [0.009 in] SPDT Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT) Differential travel max. (DT): Switching options: CONDUIT 20 mm CONDUIT 20 mm Low OF/OT/DT ELECTRICAL RATING A F A E CAT. LISTING 2LS1 2LS1-L 2LS1-4C 2LS111 31,14 N [7 lb] 1,65 mm [0.065 in] 5,56 mm [0.219 in] 0,51 mm [0.020 in] SPDT Differential travel max. (DT): Switching options: CONDUIT CONDUIT 20 mm 32 ELECTRICAL RATING A F A CAT. LISTING 5LS1 5LS1-L 5LS1-4C CAT. LISTING 4LS1 4LS1-4C Side roller plunger Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT) Top roller plunger Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT) Differential travel max. (DT): Switching options: ELECTRICAL RATING A A 40,03 N [9 lb] 2,8 mm [0.110 in] 6,35 mm [0.25 in] 1,02 mm [0.040 in] SPDT 20 mm www.honeywell.com/sensing ELECTRICAL RATING A A 40,03 N [9 lb] 2,8 mm [0.110 in] 5,56 mm [0.219 in] 1,02 mm [0.040 in] SPDT CAT. LISTING 3LS1 3LS1-4C COMPACT LIMIT SWITCHES Wobble actuated switches These switches will operate by moving actuator in any direction except direct pull. Operating force max. (OF): Pretravel max. (PT): 1,39 N [5 oz] 28,6 mm [1,125 in] SPDT Switching options: OPTIONS Coil spring Flexible cable Ø 6,17 ±0.08 (0.264 ±0.003) Ø 4,80 ±0.08 (0.189 ±0.003) 141,0 ±2,54 (5,550 ±0.10) 141,0 ±2,54 (5,550 ±0.10) CONDUIT CONDUIT 20 mm ELECTRICAL RATING D G D CAT. LISTING 8LS1 8LS1-L 8LS1-4C 20 mm ELECTRICAL RATING D D CAT. LISTING 8LS152 8LS152-4C Steel wire Operating force max. (OF): Pretravel max. (PT): Spring rod 0,28 N [1 oz] 63,5 mm [2.5 in] 191,3 (7.53) CONDUIT 20 mm CONDUIT 20 mm ELECTRICAL RATING D D ELECTRICAL RATING D D CAT. LISTING 8LS125 8LS125-4C CAT. LISTING 8LS3 8LS3-4C www.honeywell.com/sensing 33 PRECISION LIMIT SWITCHES BF Series Plastic Enclosed Basic Switches BF Series Plastic Enclosed Basic Switches are available with a wide variety of actuators, and are designed for easy mounting and wiring. BF switches are designed to allow mounting with the cover either towards or away from the mounting surface. Switches with lever type actuators are adjustable in two directions. The entire actuator can be rotated around its mounting bushing, and the angle of the lever can also be changed. Sealing: Operating temperature: Approvals: Termination: Contacts: Electrical ratings: NEMA 1, 3, 4, 13 -32 °C to 71 °C [-25 °F to 160 °F] UL ½ in - 14NPT Silver 11 A - 125 Vac, 250 Vac or 277 Vac 5 A - 125 Vac, 250 Vac or 277 Vac A B Switching options: SPDT Single Pole, Double Throw, Snap action contacts (1NC/1NO) Actuators Plunger actuated switches OPTIONS Top roller arm, adjustable Top pin plunger 14,3 0.56 18,3 0.72 ,9 39 7 1.5 Ø 7,1 Max. 0.28 23,1 0.91 Max. 17,5 0.69 65,28 2.57 44,5 1.75 4,9 9,5 0.19 0.38 34 73,6 2.90 44,5 1.75 58,7 2.31 73,5 2.89 15,5 35,1 0.61 1.38 Conduit thread 4,9 9,5 0.19 0.38 Operating force max. (OF): Differential travel max. (DT): ACTUATOR POSITION Left Right 17,5 0.69 15,5 35,1 0.61 1.38 12,23 N [44 oz] 0,64 mm [0.025 in] ELECTRICAL RATING B B CAT. LISTING BFL1-BP1 BFR1-BP1 58,7 2.31 73,5 2.89 Operating force max. (OF): Differential travel max. (DT): ACTUATOR POSITION Left Right www.honeywell.com/sensing 10,56 N [38 oz] 1,65 mm [0.065 in] ELECTRICAL RATING B B CAT. LISTING BFL1-BL1 BFR1-BL1 PRECISION LIMIT SWITCHES Plunger actuated switches (continued) Wobble actuated switches Operating force max. (OF): 1,95 N [7 oz] OPTIONS Top roller arm, adjustable, one way Coil spring Spring wire 14,3 0.56 14,3 0.56 Ø 7,1 Max. 0.28 Ø 1,02 0.05 39 1.5 ,6 6 19,05 0.75 18,3 0.72 32,26 1.27 180˚ 168,8 6.65 17,5 0.69 73,6 2.90 44,5 1.75 35,1 1.38 Ø 15,5 0.61 169,9 6.69 14,73 0.58 58,7 2.31 ACTUATOR POSITION Left Right ELECTRICAL RATING B B CAT. LISTING 35,1 1.38 44,5 1.75 58,7 2.31 73,5 2.89 4,9 9,5 0.19 0.38 3,61 N [13 oz] 10,56 N [38 oz] 17,5 0.69 15,5 35,1 0.61 1.38 44,5 1.75 4,9 9,5 0.19 0.38 73,5 2.89 Operating force max. (OF): Left Right 17,5 0.69 4,9 9,5 0.19 0.38 14,7 15,5 0.58 0.61 58,7 2.31 73,5 2.89 ACTUATOR POSITION Left Left Right ELECTRICAL RATING A B B CAT. LISTING BFL1-AW1 BFL1-BW1 BFR1-BW1 BFL1-BL3 BFR1-BL3 ACTUATOR POSITION Left Right ELECTRICAL RATING B B CAT. LISTING BFL1-BW4 BFR1-BW4 Plastic 14,3 0.56 Ø 7,1 0.28 Low force rod 250˚ 18,3 0.72 17,5 0.69 73,6 2.90 44,5 1.75 4,9 0.19 35,1 1.38 9,5 0.38 14,73 0.58 58,7 2.31 249,25 9.81 Ø 15,5 0.61 73,5 2.89 17,5 0.69 Operating force max. (OF): Left Right ACTUATOR POSITION Left Right ELECTRICAL RATING B B 10,56 N [38 oz] 3,61 N [13 oz] 44,5 1.75 35,1 1.38 CAT. LISTING BFL1-BL2 BFR1-BL2 4,9 0.19 9,5 0.38 15,5 0.61 58,7 2.31 C 73,5 2.89 Type -BW3 ACTUATOR POSITION Left, 179,3 mm [7.06 in] length rod Left, 249,25 mm [9.8 in] length rod ELECTRICAL A CAT. LISTING RATING BFL1-AW2 B BFL1-BW3 www.honeywell.com/sensing 35 PRECISION LIMIT SWITCHES BZE/DTE Series Compact Enclosed Switches The BZE/DTE Series general purpose enclosed limit switches offer enhanced precision operation and sturdy actuation in a compact but rugged metal housing. The large wiring enclosure means that the user can get access to wire the device simply. The switch incorporates high repeatability of the switch point early in the travel of the switch. This is achieved through a very tolerant over-travel mechanism aimed at reducing the effect of the application drift and the long-term accuracy of the switch. Conduit: Sealing: Operating temperature: E6 V6 Standard Low Approvals: Contacts: Actuators Electrical ratings A, B, C Electrical rating D Switching options: SPDT DPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) Double Pole, Double Throw Snap action contacts (2NC/2NO) Electrical ratings: A UL/CSA Rating: 36 ½ in - 14 NPT NEMA 1 NEMA 1, 3 -32 °C to 71 °C [-25 °F to 160 °F] -40 °C to 71°C [-40 °F to 160 °F] UL, CSA, CE Silver Gold 15 A, 125, 250 or 480 Vac: 2 A, 600 Vac: 1 /8 Hp, 125 Vac: ¼ Hp, 250 Vac: ½ A, 125 Vdc: ¼ A, 250 Vdc B UL/CSA Rating: 10 A, 125 or 250 Vac: 0.3 A, 125 Vdc: 0.15 A, 250 Vdc C UL/CSA Rating: 15 A, 125, 250 or 480 Vac; ¼ Hp, 125 Vac; ½ Hp, 250 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc D UL/CSA Rating: 1 A - 125 Vac www.honeywell.com/sensing PRECISION LIMIT SWITCHES E6/V6 E6 (side mount) and V6 (flange mount) switches are offered with or without actuator seal boots. Both have a combination insulator/ seal cemented inside the bottom enclosure. Lead washers are used to seal the mounting holes on side mount switches. All side mount switches are installed with #6 screws, except the BZE6-2RN7 (#8 screws). Removal of the bottom enclosure exposes the terminals for easy wiring. Momentary contact Top roller plunger, parallel 23,4 (0.92) OPTIONS 56,6 OP (2,23) Top pin plunger 2,0 REF (0.08) 23,4 (0.92) 25,4 (1.00) 25,4 (1.00) 10,6 (0.42) Ø 8,4 (0.33) 63,5 OP (2.50) 25,4 (1.00) 25,4 (1.00) 25,4 (1.00) 1/2-14 NPT Threads 22,6 (0.89) 77,2 (3.04) 21,1 (0.83) 41,4 (1.63) 25,4 (1.00) 54,1 (2.13) Flange mount without boot seal Side mount with boot seal With boot seal 25,4 (1.0) 22,6 (0.89) Side mount 22,6 (0.89) 69,6 (2.740) 25,4 (1.00) 77,2 (3.04) Side mount without boot seal With boot seal Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Operating force max. (OF):SPDT Standard 2,50 N to 6,67 N [9 oz to 24 oz] SPDT Low temperature 4,17 N to 10,84 N [15 oz to 39 oz] DPDT 6,95 N to 16,4 N [25 oz to 59 oz] Pretravel max. (PT): SPDT 1,98 mm [0.078 in] DPDT 2,8 mm [0.110 in] Overtravel min. (OT): SPDT 5,56 mm [0.219 in] DPDT 3,18 mm [0.125 in] Differential travel max. (DT): SPDT 0.05 mm [0.002 in] DPDT 1,52 mm [0.060 in] Ø 15,75 (0.62) 19,0 (0.75) Side mount with boot seal 4,3 Ø (2) (0.17) 44,4 (1.75) 22,6 (0.89) 77,2 (3.04) OP 49,61 (1.953) 1/2-14 NPT Threads 19,0 (0.75) Ø 8,4 (0.33) 1/2-14 NPT Threads 43,7 OP (1.72) 19,0 (0.75) 12,7 (0.50) Ø X 4,6 (0.18) Wide Roller 12,7 (0.50) Ø X 4,6 (0.18) W Roller Differential travel max. (DT): SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT 2,50 N to 6,67 N [9 oz to 24 oz] 5,56 N to 13,34 N [20 oz to 48 oz] 1,98 mm [0.078 in] 2,8 mm [0.110 in] 5,56 mm [0.219 in] 3,18 mm [0.125 in] 0,01 mm to 0,05 mm [0.0004 in to 0.0020 in] 1,52 mm [0.060 in] Side mount CONTACT SPDT DPDT ELECTRICAL RATING A B CAT. LISTING BZE6-2RN80 DTE6-2RN80 ELECTRICAL RATING A CAT. LISTING BZV6-2RN80 Flange mount Low temperature/High OF #8 screws Gold contacts CONTACT SPDT DPDT SPDT SPDT SPDT ELECTRICAL RATING A B A A D CAT. LISTING BZE6-2RN DTE6-2RN BZE6-2RN34 BZE6-2RN7 BZE6-2RN72 CONTACT SPDT CONDUIT Without boot seal Flange mount Operating force max. (OF): CONTACT SPDT DPDT ELECTRICAL RATING A B CAT. LISTING BZV6-2RN DTV6-2RN Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Without boot seal Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT 2,50 N to 3,61 N [9 oz to 13 oz] 5,56 N to 11,12 N [20 oz to 40 oz] 0,38 mm [0.015 in] 3,81 mm [0.150 in] 5,56 mm [0.219 in] 2,24 mm [0.088 in] 0,05 mm [0.002 in] 1,52 mm [0.060 in] CONTACT SPDT DPDT ELECTRICAL RATING A B CAT. LISTING BZE6-2RQ DTE6-2RQ ELECTRICAL RATING A CAT. LISTING BZV6-2RQ 2,50 N to 3,61 N [9 oz to 13 oz] 6,67 N to 13,34 N [24oz to 48 oz] 0,38 mm [0.015 in] 3,58 mm [0.141 in] 3,55 mm [0.140 in] 3,18 mm [0.125 in] 0,05 mm [0.002 in] 1,52 mm [0.060 in] Side mount CONTACT SPDT Field adjustable roller SPDT Field adjustable roller DPDT CONDUIT ELECTRICAL RATING A A B CAT. LISTING BZE6-2RQ8 BZE6-2RQ9 DTE6-2RQ9 CONDUIT ELECTRICAL RATING A CAT. LISTING BZV6-2RQ8 Flange mount CONTACT SPDT Side mount SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT Flange mount CONTACT SPDT www.honeywell.com/sensing 37 PRECISION LIMIT SWITCHES BZE/DTE Series E6/V6 Momentary contact (continued) Top roller plunger, perpendicular Roller arm, adjustable 12,7 (0.50) Ø X 4,6 (0.18) W Roller 56,6 OP (2,23) 19,0 (0.75) 25,4 (1.00) 25,4 (1.00) 22,6 (0.89) 77,2 (3.04) Side mount with boot seal Flange mount without boot seal With boot seal Operating Force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 2,60 N to 6,67 N [9 oz to 24 oz] 1,98 mm [0.078 in] 5,56 mm [0.219 in] 0,01 mm to 0,05 mm [0.0004 in to 0.0020 in] Side mount CONTACT SPDT ELECTRICAL RATING A CAT. LISTING BZE6-2RN81 Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT 2,50 N to 3,61 N [9 oz to 13 oz] 6,67 N to 13,34 N [24 oz to 48 oz] 0,38 mm [0.015 in] 3,58 mm [0.141 in] 3,55 mm [0.140 in] 3,18 mm [0.125 in] 0,05 mm [0.002 in] 1,52 mm [0.060 in] Side mount CONTACT SPDT DPDT Flange mount with boot seal Operating temperature: Standard Low Roller: -32 °C to 71 °C [-25 °F to 160 °F] -40 °C to 71 °C [-40 °F to 160 °F] Steel With boot seal Operating Force max. (OF): 2,78 N to 5,56 N [10 oz to 20 Pretravel max. (PT): 4,78 mm [0.188 Overtravel min. (OT): 5,56 mm [0.219 Differential travel max. (DT): SPDT 0,15 mm [0.006 DPDT 4,19 mm [0.165 oz] in] in] in] in] Side mount Without boot seal Operating Force max. (OF): Side mount without boot seal ELECTRICAL RATING A B CAT. LISTING BZE6-2RQ81 DTE6-2RQ81 ELECTRICAL RATING A CAT. LISTING BZV6-2RQ81 Operating Force max. (OF): Pretravel max. (PT): Low temperature DPDT DPDT CONTACT SPDT DPDT SPDT 13,34 N [48 oz] 7,92 mm [0.312 in] ELECTRICAL RATING A B A CAT. LISTING BZE6-2RN2 DTE6-2RN2 BZE6-2RN234 Flange mount Operating Force max. (OF): Pretravel max. (PT): CONTACT SPDT DPDT DPDT DPDT 2,78 N to 8,34 N [10 oz to 30 oz] 6,76 mm [0.266 in] ELECTRICAL RATING A B CAT. LISTING BZV6-2RN2 DTV6-2RN2 Flange mount CONTACT SPDT Without boot seal Operating Force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Side mount Flange mount 38 CONTACT SPDT SPDT www.honeywell.com/sensing 2,78 N to 5,00 N [10 oz to 20 4,78 mm [0.188 5,56 mm [0.219 0,15 mm [0.006 ELECTRICAL RATING A A CAT. LISTING BZE6-2RQ2 BZV6-2RQ2 oz] in] in] in] PRECISION LIMIT SWITCHES One way roller lever Manual palm button 36,6 1.44 18,3 0.72 38,1 1.50 31,8 1.25 1/2 - 14 NPSM 5 THREADS MIN 78,5 3.09 4,3 Ø (2) 0.17 44,4 1.75 22,6 0.89 77,2 3.04 Side mount with boot seal Side mount with boot seal With boot seal Operating Force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): CONTACT SPDT Side mount 41,4 1.63 25,4 1.00 54,1 2.13 With boot seal 2,22 N to 5,56 N 5,94 5,56 0,15 ELECTRICAL RATING A [8 oz to 20 mm [0.234 mm [0.219 mm [0.006 oz] in] in] in] CAT. LISTING BZE6-2RN28 Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Flange mount Rod lever CONTACT SPDT 2,78 N to 5,56 N [10 oz to 20 oz] 4,78 mm [0.188 in] 5,56 mm [0.219 in] 0,15 mm [0.006 in] ELECTRICAL RATING A CAT. LISTING BZV6-2RN4 Wobble, coil spring Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 18,24 mm [0.718 in] 21,29 mm [0.838 in] 5,82 mm [0.229 in] These switches will operate by moving actuator in any direction except direct pull. 152,4 (6.0) 18,29 (0.72) 250˚ 53,19 (2.09) Ø 15,75 (0.62) 19,05 (0.75) 25,4 (1.00) 22,6 (0.89) 69,60 (2,74) 77,2 (3.04) Flange mount without boot seal With boot seal With boot seal Operating force max. (OF): Side mount Flange mount CONTACT SPDT SPDT Flange mount with boot seal Side mount with boot seal 0,83 N to 1,95 N [3 oz to 7 oz] ELECTRICAL RATING A A CAT. LISTING BZE6-2RN62 BZV6-2RN62 Operating force max. (OF): Pretravel max. (PT): Side mount Flange mount CONTACT SPDT SPDT 1,95 N [7 oz] 15° ELECTRICAL RATING A A CAT. LISTING BZE6-2RN18 BZV6-2RN18 Without boot seal Operating force max. (OF): Side mount Flange mount CONTACT SPDT SPDT 0,56 N to 1,39 N [2 oz to 5 oz] ELECTRICAL RATING A A CAT. LISTING BZE6-2RQ62 BZV6-2RQ62 www.honeywell.com/sensing 39 PRECISION LIMIT SWITCHES BZE/DTE Series E6/V6 Maintained contact (reset) switches The switches shown below provide maintained contact after the operating force on either top or bottom plunger is released. Note: The top plungers on these switches provide enhanced accuracy and uniform operation than the “reset” plungers and should be used when closely held operating characteristics are required. Switching: SPDT Single Pole, Double Throw (1NC/1NO) Maintained OPTIONS Top pin plunger Roller arm, adjustable Side mount with boot seal Flange mount without boot seal Side mount Operating force max. (OF): With boot seal 1,67 N to 5,56 N [6 oz to 20 oz] Without boot seal 1,67 N to 2,64 N [6 oz to 9.5 oz] Pretravel max. (PT): With boot seal 1,98 mm [0.078 in] Without boot seal 0.30 mm [0.012 in] Overtravel min. (OT): 4,75 mm [0.187 in] CONTACT SPDT Maintained SPDT Maintained With boot seal Without boot seal ELECTRICAL RATING C C CAT. LISTING BZE6-RNX1 BZE6-RQX2 Flange mount with boot seal Side mount Operating Force max. (OF): With boot seal Without boot seal Pretravel max. (PT): Overtravel min. (OT): CONTACT With boot seal Without boot seal CONDUIT Maintained Maintained Top roller plunger Ø 12,7 (0.50) x 4,6 (0.18) Wide roller 56,69 (2.232) 53,19 (2.094) Reset FP 19,0 (0.75) Ø 15,75 (0.62) 25,4 (1.00) 22,6 (0.89) Ø 25,4 (1.0) 14,22 (0.56) Side mount with boot seal 40,08 (1.58) 23,19 (0.913) Side mount without boot seal 69,59 (2.74) Side mount Operating force max. (OF): With boot seal 3,34 N to 15,57 N [12 oz to 56 oz] Without boot seal 1,67 N to 2,64 N [6 oz to 9.5 oz] Pretravel max. (PT): With boot seal 1,98 mm [0.078 in] Without boot seal 0,30 mm [0.012 in] Overtravel min. (OT): With boot seal 4,75 mm [0.187 in] Without boot seal 3,55 mm [0.140 in] CONTACT With boot seal Without boot seal 40 CONDUIT SPDT SPDT ELECTRICAL RATING C C Side mount without boot seal CAT. LISTING BZE6-RN80X2 BZE6-RQ8X2 www.honeywell.com/sensing ELECTRICAL RATING C C 4,45 N [16 oz] 3,34 N [12 oz] 4,78 mm [0.188 in] 5,56 mm [0.219 in] CAT. LISTING BZE6-RN2X1 BZE6-RQ2X2 PRECISION LIMIT SWITCHES E7 Metal standard enclosed switch Mechanical life: Sealing: Without boot seal With boot seal Operating temperature: Approvals: 10 million IP50 Standard IP65 Sealed -30 °C to 70 °C [-22 °F to 158 °F] IEC 60947-5-1 EN 60947-5-1 Switching options: SPDT Actuators Single Pole, Double Throw Snap action contacts (1NC/1NO) Top roller plunger, perpendicular, without boot seal DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) 0,38 (0.015) Pretravel Ø 12,7 x 4,57 Wide roller (0.50 x 0.18) 44,53 OP (1.75) 13,97 (0.55) 25,4 (1.00) Ø 14,73 (0.58) 5,84 (0.23) OPTIONS 4,06 (0.16) CONTACT SPDT CONDUIT PG 13.5 12,7 (0.50) 76,40 (3,01) ELECTRICAL RATING CAT. LISTING BZE7-2RQ81-PG Top pin plunger With boot seal 1,93 (0.076) Pretravel Top roller lever, boot seal Ø 8,38 (0.33) Ø 19,05 x 7,92 wide roller (Ø 0.75 x 0.312) 39,88 (1.57) 38,58 OP (1.519) 18,29 (0.72) 25,4 (1.00) Ø 14,73 (0.58) 5,84 (0.23) CONTACT SPDT SPDT DPDT 4,06 (0.16) CONDUIT PG 13.5 20 mm PG 13.5 76,40 (3,01) 48,11 (1.894) 13,97 (0.55) 12,7 (0.50) 25,4 (1.00) ELECTRICAL RATING CAT. LISTING BZE7-2RN-PG BZE7-2RN-C DTE7-2RN-PG Ø 14,73 (0.58) 5,84 (0.23) CONTACT SPDT SPDT Without boot seal CONTACT SPDT 24,38 (0.91) 225˚ 13,97 (0.55) CONDUIT PG 13.5 ELECTRICAL RATING 4,06 (0.16) CONDUIT PG 13.5 20 mm 76,40 (3,01) 12,7 (0.50) ELECTRICAL RATING CAT. LISTING BZE7-2RN2-PG BZE7-2RN2-C CAT. LISTING BZE7-2RQ-PG Wobble, coil spring, boot seal Top roller plunger, parallel, without boot seal 3,8 (0.15) Pretravel Ø 12,7 x 4,5 wide roller (Ø 0.50 x 0.18) 151,13 (5.95) 44,5 OP (1.75) 13,97 (0.55) 13,97 (0.55) 25,4 (1.00) 25,4 (1.00) Ø 14,73 (0.58) 5,84 (0.23) CONTACT SPDT 4,06 (0.16) CONDUIT PG 13.5 76,40 (3,01) 5,84 (0.23) 12,7 (0.50) ELECTRICAL RATING Ø 14,73 (0.58) CAT. LISTING BZE7-2RQ8-PG CONTACT SPDT www.honeywell.com/sensing 4,06 (0.16) CONDUIT PG 13.5 76,40 (3,01) 12,7 (0.50) ELECTRICAL RATING CAT. LISTING BZE7-2RN18-PG 41 PRECISION LIMIT SWITCHES The BAF/DTF Series is available with or without boot seals. The elastomer boot on sealed actuator versions protects the actuating mechanism and the internal basic switch from contamination. They are therefore potentially suitable for wash-down applications. Both sealed and unsealed versions are available with the actuators on the right or left hand side. BAF/DTF Series High Capacity Enclosed Switches The cover plate is removable to allow ease of wiring and switch replacement without having to dismount the housing. The BAF/DTF Series is potentially suitable for use in packaging equipment, farm machinery, conveyors, overhead cranes and hoists. Actuators Approvals: Sealing: Operating temperature: Conduit: Contacts: Electrical ratings: B D Switching options: D SPDT UL, CSA NEMA 1, 3, 4, 13 -2RQ9 NEMA 1 -32 °C to 71 °C [-25 °F to 160 °F] ½ in - 14 NPT Silver UL/CSA Rating: 10 A, 125 or 250 Vac; 0.3 A, 125 Vdc; 0.15 A, 250 Vdc. Momentary contact OPTIONS Top pin plunger UL/CSA Rating: 20 A, 125, 250 or 480 Vac; 1 Hp, 125 Vac; 2 Hp, 250 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc; Lamp Load - 10 A, 125 Vac. Single Pole, Double Throw Snap action contacts (1NC/1NO) Left-hand Right-hand *28,2 on DTF2 Types 1.11 With boot seal B DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) Operating force max. (OF): BAF/DTF Pretravel max. (PT): BAF DTF Overtravel min. (OT): BAF DTF Differential travel max. (DT): BAF DTF Operating position (OP): BAF DTF ACTUATOR POSITION Right Left Right Left 42 CONTACT SPDT SPDT DPDT DPDT www.honeywell.com/sensing 2,39 3,59 5,56 3,96 0,26 1,53 53,19 52,07 ELECTRICAL RATING D D B B 11,2 N [2.5 mm [0.094 mm [0.141 mm [0.219 mm [0.156 mm [0.010 mm [0.060 mm [2.094 mm [2.050 CAT. LISTING BAF1-2RN-RH BAF1-2RN-LH DTF2-2RN-RH DTF2-2RN-LH lb] in] in] in] in] in] in] in] in] PRECISION LIMIT SWITCHES Momentary contact (continued) Roller arm, adjustable Top roller plunger, parallel Right-hand Left-hand *28,2 on DTF2 Types 1.11 O-ring actuator seal Operating force max. (OF): BAF/DTF Pretravel max. (PT): BAF/DTF Overtravel min. (OT): BAF DTF Differential travel max. (DT): BAF DTF Operating position (OP): BAF DTF ACTUATOR POSITION Right Left Right Left CONTACT SPDT SPDT DPDT DPDT 35,6 N [8.0 3,18 mm [0.125 4,75 mm [0.187 3,18 mm [0.125 0,19 mm [0.0075 1,53 mm [0.060 64,69 mm [2.547 63,88 mm [2.515 ELECTRICAL RATING D D B B lb] in] in] in] in] in] in] in] CAT. LISTING BAF1-2RQN8-RH BAF1-2RQN8-LH DTF2-2RQN8-RH DTF2-2RQN8-LH Adjustable 360° horizontally ACTUATOR POSITION Right Left Right Left CONTACT SPDT SPDT DPDT DPDT Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): ACTUATOR POSITION Right Left Right Right Field adjustable roller plunger Operating force max. (OF): BAF/DTF Pretravel max. (PT): BAF DTF Overtravel min. (OT): BAF DTF Differential travel max. (DT): BAF DTF Operating position (OP): BAF DTF With boot seal 2,39 3,18 3,96 3,18 0,26 1,53 64,69 63,88 ELECTRICAL RATING D D B B 11,2 N [2.5 mm [0.094 mm [0.125 mm [0.156 mm [0.125 mm [0.010 mm [0.060 mm [2.547 mm [2.515 lb] in] in] in] in] in] in] in] in] CONTACT SPDT SPDT DPDT DPDT BAF DTF BAF DTF BAF DTF BAF DTF ELECTRICAL RATING D D B B 8,90 N [2.0 11,1 N [2.5 5,56 mm [0.219 7,93 mm [0.312 6,35 mm [0.25 5,56 mm [0.219 0,51 mm [0.020 3,05 mm [0.120 lb] lb] in] in] in] in] in] in] CAT. LISTING BAF1-2RN2-RH BAF1-2RN2-LH DTF2-2RN2-RH DTF2-2RN2-LH One way roller lever CAT. LISTING BAF1-2RQ9-RH BAF1-2RQ9-LH DTF2-2RQ9-RH DTF2-2RQ9-LH With boot seal Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): ACTUATOR POSITION CONTACT Right SPDT Left SPDT www.honeywell.com/sensing 8,90 N [2.0 5,56 mm [0.219 6,35 mm [0.25 0,51 mm [0.020 ELECTRICAL RATING D D lb] in] in] in] CAT. LISTING BAF1-2RN28-RH BAF1-2RN28-LH 43 PRECISION LIMIT SWITCHES BAF/DTF Series Momentary contact (continued) Maintained contact (reset) switches Manual palm button Top pin plunger Right-hand Left-hand *28,2 on DTF2 Types 1.11 With boot seal With boot seal Operating force max. (OF): ACTUATOR POSITION CONTACT Right SPDT Left SPDT 8,90 N [2.0 lb] ELECTRICAL RATING D D CAT. LISTING BAF1-2RN4-RH BAF1-2RN4-LH Wobble, coil spring Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): ACTUATOR POSITION CONTACT Right Maintained SPDT ELECTRICAL RATING D CAT. LISTING BAF1-3RNX1 Roller arm, adjustable Left-hand Right-hand With boot seal Pretravel max. (PT): ACTUATOR POSITION CONTACT Right SPDT Left SPDT 7,79 N [1.75 lb] 2,39 mm [0.094 in] 5,56 mm [0.219 in] 82,6 (3.25) 101,6 (4.00) 15° ELECTRICAL RATING D D CAT. LISTING BAF1-2RN18-RH BAF1-2RN18-LH With boot seals on roller arm and plunger Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Operating position (OP): ACTUATOR POSITION CONTACT Right Maintained SPDT Left Maintained SPDT 44 www.honeywell.com/sensing 6,67 N [1.5 5,56 mm [0.219 6,35 mm [0.25 60,71 mm [2.390 ELECTRICAL RATING D D CAT. LISTING BAF1-3RN2X-RH BAF1-3RN2X-LH lb] in] in] in] PRECISION LIMIT SWITCHES Wobble, coil spring 32,5 (1.28) Ø 7,1 (0.28) 158,5 (6.24) 1/2-14 NPT Threads Ø 6,9 (3) (0.27) 27,4 (1.08) 20,6 (0.81) 41,4 (1.63) 27,4 (1.08) 82,6 (3.25) 101,6 (4.00) With boot seals on wobble stick and plunger Pretravel max. (PT): ACTUATOR POSITION CONTACT Right Maintained SPDT 15° ELECTRICAL RATING D CAT. LISTING BAF1-3CN18X1 www.honeywell.com/sensing 45 HEAVY DUTY LIMIT SWITCHES HDLS Series Heavy Duty Limit Switches The HDLS Series Heavy Duty Limit Switches offer a wide choice of mounting and actuator options. Housed in a rugged, die-cast zinc body, the switch is epoxy coated for protection. Potential applications include harsh duty environments where conventional limit switches may not be used. Versatile and full featured, they are designed for long life. Listings referenced in this section are mainly standard. Low temperature and fluorocarbon (FC, high temperature) construction is available in all forms of HDLS limit switches. For temperature ranges see table opposite. Also available are factory sealed, pre-wired switches. Low temperature switches have fluorosilicone diaphragm, shaft seals and external boot seal (where applicable) plus a low temperature lubricant. If prewired with cable, temperature limits are 10 °C [14 °F] flex and -30 °C [22 °F] no flex. To order a low temperature version insert the additional letters Y and B as in the following example: LSA1A - standard side rotary plug-in switch LSYAB1A - low temperature version. Completely fluorocarbon (FC) sealed, high temperature, chemical resistance switches have a full FC body gasket covering the switch cavity. Rotary types have an extra FC seal on the operating shaft, while plunger versions have FC boot seals. They are for use in potential applications where the environment includes fire-resistant synthetic fluids. The additional FC seals also promote enhanced operating life for rotary actuacted HDLS switches in applications where the temperatures are normally -12 °C to 121 °C [10 °F to 250 °F]. If prewired with cable, temperature limits are 105 °C [221 °F] dry and 60 °C [140 °F] wet. To order a fluorocarbon (FC) sealed switch insert the additional letters Y and C as in the following example: LSA1A - standard side rotary plug-in switch LSYAC1A - completely FC sealed version. Actuators Factory sealed, pre-wired limit switches have the entry area completely sealed and are available with 6 ft [1,83 m], STOOW-A cable or 4, 5 or 9-pin connectors. NEMA ratings are, for cable version 1, 4, 6, 6P, 12, for connector version 1, 4, 6, 6P, 12, 13. To order a factory sealed switch add the appropriate letter: Circuitry only) Cable ½ in Connector (available with ½ in conduit tap SPDT C A (4 pin mini) B (5 pin mini) Levers: Levers for side rotary types are ordered separately (see pages 71-73 for details) DD (4 pin micro) DPDT M (¾ in only) R (9 pin) Example: LSA1AC - LSA1A with 6 ft of 5 conductor STOOW-A cable LSJ2BM-7N - LSJ2B-7N with 6 ft of 9 conductor STOOW-A cable LSA1AB - LSA1A with 5 pin receptable LSA1ADD - 4 pin micro-change connector Electrical ratings 10 amps continuous carry. Circuits on any one pole must be the same polarity. ac Volts Pilot duty: 600 Vac, 720 VA A SPDT NEMA A600 B DPDT NEMA B600 C SPDT/DPDT Amps at 0.35 Power Factor Vac Make Break 120 60 6 240 30 3 480 15 1.5 600 12 1.2 120 30 3 240 15 1.5 480 7.5 0.75 600 6 0.60 250 Vac or 60 Vdc, 0.050 amp max. dc Volts Pilot duty: 240 Vdc, 30 watts A SPDT B DPDT C SPDT/DPDT 46 Make and Break Amps Vdc Inductive 120 0.25 240 0.15 120 0.25 240 0.15 250 Vac or 60 Vdc, 0.050 amp max. www.honeywell.com/sensing Resistive 0.8 0.4 0.8 0.4 HEAVY DUTY LIMIT SWITCHES Operating temperatures Environmental seal performance www.honeywell.com/sensing 47 HEAVY DUTY LIMIT SWITCHES HDLS Series Side rotary actuated switches Levers: Levers for side rotary types are ordered separately (see pages 69-71 for details) Sealing IP67, 68 (except preleaded versions) NEMA 1, 3, 4, 4X, 6, 6P, 12, 13 UL, CSA, CE, CCC Operating force (Newton meters, N m/in lb): LSA, LSL, LSM, LSM, LSP, LSU LSH, LSR Conduit: Contacts: Electrical ratings A, B Electrical rating C Switching options: SPDT 0,45 N m max. 4 in lb max. 0,19 N m max. 1.7 in lb max ½ in - 14 NPT Silver Gold Snap action contacts Side rotary, momentary action The momentary action listings shown are factory assembled with the head adjusted for both clockwise (CW) and counterclockwise (CCW) operation. The shaft of side rotary heads face the front (label side of switch). Actuation direction A simple field adjustment converts switch to accept actuation from one or both directions. For ready reference, adjustment instructions are cast into the internal lid of side rotary heads. DPDT SPDT Double Break DPDT Double Break Head orientation The head may be orientated and locked in any of four 90° positions. Momentary action switches can be factory assembled for operation in one direction only and/or with the shaft facing the rear or either side. Contact Honeywell for more information. 48 www.honeywell.com/sensing HEAVY DUTY LIMIT SWITCHES OPTIONS Low differential, low torque Standard Pretravel: Differential travel: Pretravel: Differential travel: SPDT DPDT Overtravel: 15° max. 5° max. 7° max. 60° min. Plug in CONTACT CONDUIT SPDT SPDT DPDT ¾ in DPDT DPDT SPDT 20 mm DPDT 20 mm ELECTRICAL RATING A C B B C A B CAT. LISTING LSA1A LSA1E LSA2B LSA6B LSA6S LS4A1A LS4A2B Non plug in CONTACT CONDUIT SPDT DPDT ¾ in SPDT 20 mm ELECTRICAL RATING A B A CAT. LISTING LSA3K LSA4L LS4A3K SPDT DPDT Overtravel: 9° max. 3° max. 4° max. 66° min. Plug in CONTACT SPDT SPDT DPDT DPDT DPDT Overtravel: ELECTRICAL RATING A C B B C CAT. LISTING LSP1A LSP1E LSP2B LSP6B LSP6S ELECTRICAL RATING A B CAT. LISTING LSP3K LSP4L 9° max. 3° max. 4° max. 66° min. Plug in CONTACT CONDUIT SPDT SPDT DPDT ¾ in DPDT DPDT ELECTRICAL RATING A C B B C CAT. LISTING LSH1A LSH1E LSH2B LSH6B LSH6S Non plug in CONTACT CONDUIT SPDT DPDT ¾ in ELECTRICAL RATING A B CAT. LISTING LSH3K LSH4L 5° Pretravel Pretravel: Differential travel: SPDT DPDT Overtravel: Low differential travel Pretravel: Differential travel: SPDT DPDT Side rotary, additional circuitry/ action OPTIONS Sequential One pole operates before the other in each direction, with 10° lever travel between operations. Pretravel: 1st pole 15° max. 2nd pole additional 10° max. Differential travel: Each pole 5° max. Overtravel: 48° min. Switching options: 5° max. 3° max. 4° max. 70° min. Plug in CONTACT CONDUIT SPDT SPDT DPDT ¾ in DPDT DPDT ELECTRICAL RATING A C B B C CAT. LISTING LSU1A LSU1E LSU2B LSU6B LSU6S ELECTRICAL RATING A B CAT. LISTING LSU3K LSU4L (2) SPDT Double Bread with 10˚ between operation Plug in CONTACT CONDUIT DPDT ¾ in DPDT ELECTRICAL RATING B B CAT. LISTING LSL2C LSL6C ELECTRICAL RATING B B CAT. LISTING LSL4M LSL7M Non plug in CONTACT CONDUIT SPDT DPDT ¾ in Non plug in CONTACT CONDUIT SPDT DPDT ¾ in The following listings, sequential, centre neutral and maintained switches, are assembled with the operating shaft facing front. The user can position and lock the head with the shaft to rear or either side. They can also be factory assembled with the shaft to rear or either side. Contact Honeywell for more information. Non plug in CONTACT CONDUIT DPDT ¾ in DPDT Centre neutral One pole operates on clockwise rotation, the other on counterclockwise rotation. Low torque Pretravel: Differential travel: SPDT DPDT Overtravel: Pretravel: Differential travel: Overtravel: Switching options: 15° max. 5° max. 7° max. 60° min. 18° max. 10° max. 57° min. Plug in CONTACT CONDUIT SPDT SPDT DPDT ¾ in DPDT DPDT ELECTRICAL RATING A C B B C CAT. LISTING LSR1A LSR1E LSR2B LSR6B LSR6S SPDT Double Break each direction Plug in CONTACT CONDUIT DPDT ¾ in SPDT 20 mm DPDT Non plug in CONTACT CONDUIT SPDT DPDT ¾ in ELECTRICAL RATING A B CAT. LISTING LSR3K LSR4L ELECTRICAL RATING B B B CAT. LISTING LSM2D LS4M2D LSM6D ELECTRICAL RATING B B CAT. LISTING LSM4N LSM7N Non plug in CONTACT CONDUIT DPDT ¾ in DPDT www.honeywell.com/sensing 49 HEAVY DUTY LIMIT SWITCHES HDLS Series Side rotary actuated switches (continued) Plunger actuated switches Maintained contact, 2 position Operation is maintained on counterclockwise rotation, reset on clockwise rotation and vice versa. Pretravel: Differential travel: Overtravel: Switching options: SPDT 65° max. 40° max. 20° min. DPDT HDLS plunger actuated switches are available with either top or side facing plungers for application flexibility. Switches with adjustable plungers simplify installation. They have a hex setscrew and locknut on the plunger, providing an adjustment range of 0.25 in [6,35 mm]. Assembled conditions The listing shown are factory assembled with side plungers facing front (label side of switch); rollers on side plungers are in horizontal position. Rollers on top plunger switches are parallel to mounting surface. Other options are available. Contact Honeywell for more information. Approvals: SPDT Double Break Maintained DPDT Double Break Maintained NEMA 1, 3, 4, 4X, 6, 6P, 12, 13 UL, CSA, CE ½ in - 14 NPT Conduit: Contacts: Electrical ratings A, B Electrical rating C Switching options: SPDT Silver Gold Snap action contacts DPDT Plug in CONTACT SPDT DPDT ELECTRICAL RATING A B CAT. LISTING LSN1A LSN6B ELECTRICAL RATING A B CAT. LISTING LSN3K LSN7L Non plug in CONTACT SPDT DPDT Top roller plunger Operating point: Plug in CONTACT SPDT SPDT DPDT DPDT DPDT Double Break ELECTRICAL RATING A C B C CAT. LISTING LSD1A LSD1E LSD6B LSD6S ELECTRICAL RATING A B CAT. LISTING LSD3K LSD7L Non plug in CONTACT SPDT DPDT SPDT Double Break 55,9 mm ± 1,02 2,20 in ± 0.040 Adjustable plunger Top plungers, momentary action Pretravel: Differential travel: SPDT DPDT Overtravel: Operating force: 1,78 mm [0.07 in] max. 0,38 mm [0.015 in] max. 0,51 mm [0.02 in] max. 4,83 mm [0.19 in] min. 17,8 N m [4 lb] max. OPTIONS Operating point: Top pin plunger Plug in CONTACT SPDT SPDT DPDT DPDT 53,0 mm to 59,3 mm 2.085 in to 2.335 in ELECTRICAL RATING A C B C CAT. LISTING LSV1A LSV1E LSV6B LSV6S ELECTRICAL RATING A B CAT. LISTING LSV3K LSV7L Non plug in Operating point: 45,8 mm ± 0,76 1.805 in ± 0.030 Plug in CONTACT SPDT SPDT DPDT DPDT ELECTRICAL RATING A C B C CAT. LISTING LSC1A LSC1E LSC6B LSC6S ELECTRICAL RATING A B CAT. LISTING LSC3K LSC7L Non plug in CONTACT SPDT DPDT 50 www.honeywell.com/sensing CONTACT SPDT DPDT HEAVY DUTY LIMIT SWITCHES Side plungers, momentary action Pretravel: Differential travel: SPDT DPDT Overtravel: Operating force: Side roller plunger Side plunger, maintained circuitry 2,54 mm [0.100 in] max. 0,64 mm [0.025 in] max. 0,89 mm [0.035 in] max. 4,83 mm [0.19 in] min. 26,7 N m [6 lb] max. OPTIONS Side pin plunger Operating point: 39,6 1.56 Plug in 14,7 .58 CONTACT SPDT SPDT DPDT DPDT 20,3 31,37 .80 1.24 Operating point: 33 mm ± 0,76 1.300 in ± 0.030 Plug in CONTACT SPDT SPDT DPDT DPDT 44,1 mm ± 1,02 1.735 in ± 0.040 ELECTRICAL RATING A C B C CAT. LISTING LSE1A LSE1E LSE6B LSE6S ELECTRICAL RATING A B CAT. LISTING LSE3K LSE7L ELECTRICAL RATING A C B C CAT. LISTING LSF1A LSF1E LSF6B LSF6S ELECTRICAL RATING A B CAT. LISTING LSF3K LSF7L Non plug in CONTACT SPDT DPDT LSG contact transfer is maintained after either plunger is operated. Operation of other plunger resets switch. Pretravel: 4,32 mm [0.170 in] max. Differential travel: SPDT 2,29 mm [0.090 in] max. DPDT 2,29 mm [0.090 in] max. Overtravel: 2,00 mm [0.0.80 in] max. Operating force: 44,5 N m [10 lb] min. Operating point: 37,6 ± 0,76 mm 1.48 ± 0.030 in Switching options: SPDT DPDT Non plug in CONTACT SPDT DPDT Plug in CONTACT SPDT SPDT DPDT DPDT Adjustable side pin plunger ELECTRICAL RATING A C B C CAT. LISTING LSG1A LSG1E LSG6B LSG6S ELECTRICAL RATING A B CAT. LISTING LSG3K LSG7L Non plug in CONTACT SPDT DPDT Operating point: 41,0 mm to 47,4 mm 1.615 in to 1.865 in Plug in CONTACT SPDT SPDT DPDT DPDT ELECTRICAL RATING A C B C CAT. LISTING LSW1A LSW1E LSW6B LSW6S ELECTRICAL RATING A B CAT. LISTING LSW3K LSW7L Non plug in CONTACT SPDT DPDT www.honeywell.com/sensing 51 HEAVY DUTY LIMIT SWITCHES HDLS Series Wobble actuated switches Momentary action wobble actuated switches have flexible levers which may be operated with any movement, except direct pull. Approvals: Spring wire Cat whisker NEMA 1, 3, 4, 4X, 6, 6P, 12, 13 UL, CSA, CE ½ in - 14 NPT Conduit: Contacts: Electrical ratings A, B Switching options: SPDT Silver Snap action contacts DPDT Pretravel (approx) (Radius): Operating force: SPDT Double Break DPDT Double Break Plastic rod Pretravel (approx) (Radius): 51,0 mm [2.0 in] Operating force: 1,39 N [5.0 oz] max. Plug in CONTACT SPDT DPDT OPTIONS 102,0 mm [4.0 in] 1,39 g [5 oz] max. ELECTRICAL RATING A B CAT. LISTING LSJ1A-7M LSJ6B-7M CONTACT SPDT DPDT Non plug in CONTACT SPDT DPDT Plug in ELECTRICAL RATING A B CAT. LISTING LSJ3K-7M LSJ7L-7M ELECTRICAL RATING A B CAT. LISTING LSK1A-8A LSK6B-8A ELECTRICAL RATING A B CAT. LISTING LSK3K-8A LSK7L-8A Non plug in CONTACT SPDT DPDT Cable Coil spring Pretravel (approx) (Radius): 25,4 mm [1.0 in] Operating force: 2,78 g [10 oz] max. Plug in CONTACT SPDT DPDT ELECTRICAL RATING A B CAT. LISTING LSJ1A-7A LSJ6B-7A Pretravel (approx) (Radius): 38,0 mm [1.5 in] Operating force: 1,95 N [7.0 oz] max. Non plug in CONTACT SPDT DPDT ELECTRICAL RATING A B CAT. LISTING LSJ3K-7A LSJ7L-7A Pretravel (approx) (Radius): 51,0 mm [2.0 in] Operating force: 1,95 N [7.0 oz] max. Plug in CONTACT SPDT DPDT ELECTRICAL RATING A B CAT. LISTING LSJ1A-7N LSJ6B-7N CONTACT SPDT DPDT Non plug in CONTACT SPDT DPDT Plug in ELECTRICAL RATING A B CAT. LISTING LSJ3K-7N LSJ7L-7N www.honeywell.com/sensing CAT. LISTING LSK1A-8C LSK6B-8C ELECTRICAL RATING A B CAT. LISTING LSK3K-8C LSK7L-8C Non plug in CONTACT SPDT DPDT 52 ELECTRICAL RATING A B HEAVY DUTY LIMIT SWITCHES Fully potted HDLS Fully potted HDLS are designed to meet the demanding requirements of NEMA 1, 3, 4, 6, 6P and 13 for wet applications where the integrity of the conduit seal must be assured. These switches are the same as the standard HDLS non plug in limit switch except that the conduit entrance is factory sealed to simplify installation and ensure integrity of the conduit seal. They are epoxy filled and supplied with six feet of 5 or 9 conductor 16 gauge STO cable. Fully potted HDLS are built with all Fluorocarbon seals. Sealing exceeds Nema 6P. Low temperature versions are available, see page 46 for temperature range and how to order. 41,1 1.62 14,7 0.58 NEMA 1, 4, 6, 6P, 12, 13 NEMA 1, 4, 6, 6P, 12 UL, CSA, CE, CCC Operating temperature: Cable versions -12 °C to 105 °C 10 °F to 221 °F Connector versions -12 °C to 121 °C 10 °F to 250 °F Cable length: 3,658 m [12 ft] Contacts: Electrical ratings A, B Silver Switching options: Snap action contacts SPDT DPDT 39,6 1.56 59,4 2.34 Levers: Levers for side rotary types are ordered separately (see pages 71-73 for details) OPTIONS Standard Pretravel: Differential travel: 70,4 2.77 CONTACT SPDT DPDT SPDT DPDT Wiring diagrams: Single-Pole 5,2 0.20 Ø Mtg holes (2) Side rotary actuated switches Overtravel: Operating force: 25,4 1.00 36,6 1.44 19,0 0.75 106,7 4.20 Approvals: Connector Cable Numbers = Connectors Colours = Cables Double-Pole 29,4 1.16 10-32 UNF tapped from rear only (2) TERMINATION Cable Cable 5-pin Connector 9-pin Connector Mtg pads 7,32 0.29 Actuators ELECTRICAL RATING A B A B CAT. LISTING LSYAC3KP-FP LSYAC4LX-FP LSYAC3KQ-FP LSYAC7LR-FP Low differential travel Pretravel: Differential travel: Overtravel: Operating force: 62,0 2.44 15° max. 5° max. 7° max. 60° min. 0,45 N m [4 in lb] max. SPDT DPDT CONTACT SPDT DPDT SPDT DPDT TERMINATION Cable Cable 5-pin Connector 9-pin Connector 9° max. 3° max. 4° max. 66° min. 0,45 N m [4 in lb] max. SPDT DPDT ELECTRICAL RATING A B A B CAT. LISTING LSYPC3KP-FP LSYPC4LX-FP LSYPC3KQ-FP LSYPC7LR-FP 74,9 2.95 5° Pretravel Pretravel: Differential travel: Overtravel: Operating force: 1/2-14 NPT 20,3 0.80 39,0 1.54 44,4 1.75 5° max. 3° max. 70° min. 0,45 N m [4 in lb] max. SPDT CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING SPDT Cable A LSYUC3KP-FP SPDT 5-pin Connector A LSYUC3KQ-FP For low temperature versions substitute “Y_B” for “Y_C” www.honeywell.com/sensing 53 HEAVY DUTY LIMIT SWITCHES Fully potted HDLS (continued) Side rotary actuated switches Sequential Pretravel: 1st pole 15° max. 2nd pole additional 10° max. Differential travel: Each pole 5° max. Overtravel: 48° max. Operating force: 0,45 N m [4 in lb] max. Switching options: DPDT Plunger actuated switches OPTIONS Top plungers Pretravel: Differential travel: SPDT DPDT Overtravel: Operating force: 1,78 mm [0.07 in] max. 0,38 mm [0.015 in] max. 0,51 mm [0.02 in] max. 4,83 mm [0.19 in] min. 17,8 N m [4 lb] max. Top pin plunger CONTACT SPDT DPDT SPDT DPDT TERMINATION Cable Cable 5-pin Connector 9-pin Connector ELECTRICAL RATING A B A B CAT. LISTING LSYCC3KP-FP LSYCC4LX-FP LSYCC3KQ-FP LSYCC7LR-FP (2) SPDT Double Break with 10˚ between operation CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING DPDT Cable B LSYLC4MX-FP DPDT 9-pin Connector B LSYLC7MR-FP CONTACT SPDT DPDT SPDT DPDT Centre neutral Pretravel: Differential travel: Overtravel: Operating force: Switching options: Top roller plunger 18° max. 10° max. 57° min. 0,45 N m [4 in lb] max. DPDT TERMINATION Cable Cable 5-pin Connector 9-pin Connector ELECTRICAL RATING A B A B CAT. LISTING LSYDC3KP-FP LSYDC4LX-FP LSYDC3KQ-FP LSYDC7LR-FP Side plungers Pretravel: Differential travel: SPDT DPDT Overtravel: Operating force: 2,54 mm [0.100 in] max. 0,38 mm [0.015 in] max. 0,51 mm [0.02 in] max. 4,83 mm [0.19 in] min. 26,7 N m [6 lb] max. Side pin plunger SPDT Double Break each direction CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING DPDT Cable B LSYMC4NX-FP DPDT 9-pin Connector B LSYMC7NR-FP CONTACT SPDT DPDT SPDT DPDT TERMINATION Cable Cable 5-pin Connector 9-pin Connector ELECTRICAL RATING A B A B CAT. LISTING LSYEC3KP-FP LSYEC4LX-FP LSYEC3KQ-FP LSYEC7LR-FP For low temperature versions substitute “Y_B” for “Y_C” 54 www.honeywell.com/sensing Wobble actuated switches Actuator codes **: 7A 7M 8A 7N 8C CONTACT TERMINATION SPDT DPDT SPDT DPDT Cable Cable 5-pin Connector 9-pin Connector Delrin rod Spring wire Cat whisker Cable Coil spring ELECTRICAL RATING A B A B Head style* J J K J K CAT. LISTING LSY*C3KP-**FP LSY*C4LX-**FP LSY*C3KQ-**FP LSY*C7LR-**FP HEAVY DUTY LIMIT SWITCHES Stainless steel HDLS Plunger actuated switches Side rotary actuated switches OPTIONS Top roller plunger Pretravel: Differential travel: Overtravel: Operating point: HDLS stainless steel switches are designed for use in highly corrosive environments such as petro-chemical plants, food processing plants, shipboard and dockside locations. The type 316 cast stainless steel body is designed to minimise crevices where food particles could become trapped. The actuator, operating head and screws are also stainless steel. All seals are Fluorocarbon to provide excellent chemical resistance and to withstand operating temperatures up to 121 °C [250 °F] and pressurised steam cleaning. CONTACT SPDT DPDT CAT. LISTING LS2D4K LS2D4L 39,6 1.56 33,0 1.30 Operating point 14,7 .58 NEMA 1, 3, 3R, 4, 4X, 6, 6P, 12, 13 UL, CSA, CE, CCC Operating temperature: -12 °C to 121 °C 10 °F to 250 °F Contacts: Electrical ratings A, B Silver Actuators ELECTRICAL RATING A B Side pin plunger Approvals: Levers: Levers for side rotary types are ordered separately (see pages 71-73 for details) 1,78 mm [0.07 in] max. 0,38 mm [0.015 in] max. 4,83 mm [019 in] min. 55,9 mm ± 1,02 2.20 in ± 0.04 20,3 31,37 .80 1.24 Pretravel: Differential travel: Overtravel: Operating point: OPTIONS Standard Pretravel: Differential travel: SPDT DPDT Overtravel: CONTACT SPDT DPDT ELECTRICAL RATING A B 15° max. 5° max. 7° max. 60° min CAT. LISTING LS2A4K LS2A4L SPDT DPDT Overtravel: CONTACT SPDT DPDT ELECTRICAL RATING A B 9° max. 3° max. 4° max. 60° min. CAT. LISTING LS2H4K LS2H4L Centre neutral Pretravel: Differential travel: Overtravel: CONTACT DPDT ELECTRICAL RATING B CONTACT SPDT DPDT DPDT 18° max 10° max. 57° min. 9,4 0.37 2,54 mm [1.00 in] max. 0,64 mm [0.025 in] max. 4,83 mm [0.19 in] min. 33 mm ± 0,76 1.3 in ± 0.03 ELECTRICAL RATING A B CAT. LISTING LS2E4K LS2E4L Side roller plunger 47,7 1.88 39,6 1.56 4,8 0.19 Low Torque Pretravel: Differential travel: 19,0 0.75 21,6 0.85 44,2 1.74 Operating point 14,7 0.58 19,1 0.75 Pretravel: Differential travel: Overtravel: Operating point: CONTACT SPDT DPDT 31,5 1.24 21,6 0.85 20,3 0.80 2,54 mm [1.00 in] max. 0,64 mm [0.025 in] max. 4,83 mm [0.19 in] min. 44,1 mm ± 1,02 1.73 in ± 0.04 ELECTRICAL RATING A B CAT. LISTING LS2F4K LS2F4L CAT. LISTING LS2M4N www.honeywell.com/sensing 55 56 www.honeywell.com/sensing HAZARDOUS LOCATION SWITCHES Hazardous location switches Honeywell explosion proof switches are designed specifically for use in hazardous locations. To comply with explosion-proof requirements, the flame path within the housing is designed to contain and cool the escaping hot gases that otherwise could cause an explosion outside the switch. Switches are available with UL/CSA for North America. See information below and product pages for details. In Europe, the usage is governed under the European Directive on Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres (94/9/EC) commonly referred to as the ATEX Directive. The BX, CX and GXE product families comply to the following ATEX Directive: EExd IIC T6 Category II 2 GD The 14CE100 product family complies to the following ATEX Directive: EExd IIC T6 Category II 2 G NEMA TYPE 7, CLASS I FLAMMABLE GASES OR VAPORS Type 7 enclosures are for use indoors in locations classified as Class I, Groups B, C, or D by the National Electrical Code. Group B — (only switches so noted in the order guides include this listing). Atmospheres containing hydrogen or manufactured gas. Group C — atmospheres containing diethyl ether, ethylene, or cyclopropane. Group D — Atmospheres containing gasoline, hexane, butane, naptha, propane, acetone, toluene or isoprene. Division 1 Locations in which hazardous agents are present under normal operating conditions. Division 2 Locations in which hazardous agents may be present only in case of accidental rupture or breakdown. All Honeywell listings covered in Division 1 are also covered in the same groups in Division 2. NEMA TYPE 9, CLASS II COMBUSTIBLE DUSTS Type 9 enclosures are for use in indoor locations classified as Class II, Groups E, F or G, as defined in the National Electrical Code. Group E — Atmospheres containing metal dust. Group F — Atmospheres containing carbon black, coal dust or coke dust. Group G — Atmospheres containing flour, starch or grain dust. ATEX EExd EExd II Flameproof Places with potentially enclosure explosive atmospheres, other than mines susceptible to fire damp c T6 Atmosphere may contain gases from groups A, B or C from table in EN50014, Annex A Maximum surface temperature of 85 °C [185 °F] Category II 2 Areas in which an explosion proof atmosphere is likely to occur www.honeywell.com/sensing G Gas could be present D Dust could be present 57 HAZARDOUS LOCATION SWITCHES 14CE100 Series Miniature Enclosed, Explosion Proof X ATEoved Switches r p p a The 14CE100 Series has been designed for use in explosive environments. It is approved to meet the requirements of the Low Voltage directive and is CE marked. The prewired construction allows for ease of installation where space is at a premium and external operating conditions can be difficult. Mechanical life: Sealing: 10 million IP65, NEMA 1, 3 IP67 , NEMA 1, 3, 4 12, 13 0 °C to 70 °C [32 °F to 158 °F] CE, PTB 98 ATEX 1064 X EExd IIC T6 Category II 2 G AC14 D300 DC13 R300 11,8 N max. 1,8 mm [0.71 in] max. 3,0 mm [0.118 in] min. 0,1mm [0.004 in] max. Standard Silver -*G Gold Harmonised CENELEC 4 x 0,75 mm2 cable Standard Boot sealed Operating temperature: Approvals: Operating force (OF): Pretravel (PT): Overtravel (OT): Differential travel (DT): Contacts: Connection: Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) Actuators S.P.D.T BROWN 2 GREEN/YELLOW BLUE 1 3 BLACK Top pin plunger 40,0 Max. 1,57 25,0 1.00 M4 ground screw 15,7 OP 0.62 Top roller plunger, parallel 16,0 Max. 0.63 1,8 PT 0.07 M4 ground screw 40,0 Max. 1,57 25,0 1.00 M4 ground screw Ø 10,0 (0.39) Stainless steel plunger (2) Ø 5,1 (0.20) Mounting holes 49,0 Max. 1.93 31,4 1.24 1,8 PT 0.07 Ø 12,0 (0.47) x 5,0 (0.20) Hardened steel roller CAT. LISTING 14CE101-1 14CE101-2 14CE101-3 14CE101-4 14CE101-5 14CE101-6 14CE101-10 Boot sealed 1,80 Max. (0.07) PT 72,0 2,83 31,4 1.24 49,0 Max. 1.93 CABLE LENGTH 1 m [3.3 ft] 3 m [9.9 ft] 3 m [9.9 ft] Gold contacts 5 m [16.5 ft] 6 m [19.8 ft] 6 m [19.8 ft] Gold contacts 8 m [26.4 ft] 12 m [39.6 ft] 15 m [49.5 ft] 14,0 0.55 31,4 1.24 49,0 Max. 1.93 7,6 0.30 "L" CAT. LISTING 14CE102-1 14CE102-3 14CE102-3G 14CE102-5 14CE102-6 14CE102-6G 14CE102-8 14CE102-12 14CE102-15 Ø 7,1 (0.28) Stainless steel plunger Neoprene boot seal 58 (2) Ø 5,1 (0.20) Mounting holes 72,0 2,83 7,6 0.30 24,9 (0.98) OP CABLE LENGTH 1 m [3.3 ft] 6 m [19.8 ft] 10 m [33.0 ft] 1,8 PT 0.07 28,5 OP 1.11 "L" CABLE LENGTH 1 m [3.3 ft] 2 m [6.6 ft] 3 m [9.9 ft] 4 m [13.2 ft] 5 m [16.5 ft] 6 m [19.8 ft] 10 m [33.0 ft] 16,0 Max. 0.63 (2) Ø 5,1 (0.20) Mounting holes 7,6 0.30 "L" 40,0 Max. 1,57 25,0 1.00 16,0 Max. 0.63 28,5 OP 1.11 59,0 2.32 Top roller plunger, perpendicular CAT. LISTING 14CE118-1 14CE118-6 14CE118-10 www.honeywell.com/sensing CABLE LENGTH 1 m [3.3 ft] 3 m [9.9 ft] CAT. LISTING 14CE103-1 14CE103-3 HAZARDOUS LOCATION SWITCHES GXE Series Explosion Proof Limit Switches X ATEoved r app The GXE Series explosion proof limit switches are designed specifically for use in hazardous applications. The GXE enclosure is fully potted and has sealing protection of IP66/67 as per IEC/ EN 60529. The entire GXE Series complies with the European Directive on Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres (94/9/EC) commonly referred to as the ATEX Directive. Mechanical life: Sealing: Operating temperature: Approvals: 2 million IP66/67, EN 60529 -20 °C to 75 °C [-4 °F to 167 °F] CE, EN 50014, EN 50018, EN 50281-1-1 KEMA 00 ATEX 2103 X EExd IIC T6 T85 Category II 2 GD AC15 DC13 Silver 5 metre, HO5VV-F, 3 x 0,75 mm2 cable Contacts: Connection: Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) BLUE BLACK BROWN Actuators OPTIONS GXE Series Side rotary roller lever Overtravel min. (OT): Differential travel max. (DT): Operating position max. (OP): Top roller plunger, parallel 49° 8° 26° CAT. LISTING GXE51A1B Operating force max. (OF): Overtravel min. (OT): 6,0 mm [0.0.236 in] Differential travel max. (DT): 0,5mm [0.020 in] Operating position max. (OP): 2,0 mm [0.079 in] CAT. LISTING GXE51C 16 N [3.6 lb] Top pin plunger Overtravel min. (OT): 6,0 mm [0.0.236 in] Differential travel max. (DT): 0,5mm [0.020 in] Operating position max. (OP):2,0 mm [0.079 in] CAT. LISTING GXE51B www.honeywell.com/sensing 59 HAZARDOUS LOCATION SWITCHES EX Series Standard Explosion Proof Switches The EX Series features the smallest UL listed housings available for use in hazardous locations. Flame paths within the housing are designed to cool exploding gases below the kindling temperature before they reach the explosive gases surrounding the housing. X ATEoved r app Options available include single or double conduit connection. These switches are not sealed against liquids and should not be used where there will be liquid splash. If a weather sealed explosion proof switch is required please select from the CX or LSX/BX series. Actuators Sealing: NEMA 1, 7 (Class I, Division I, Groups C, D) 9, (Class II, Division I, Groups E, F, G) Operating temperature: Standard -40 °C to 71 °C [-40 °F to 160 °F] High 100 hr @ 400 °F Approvals: UL, CSA, KEMA 04ATEX2312X Conduit: ½ in - 14NPT Contacts: Silver Electrical ratings: A UL/CSA Rating: 15 A, 125, 250 or 480 Vac; 1 /8 Hp, 125 Vac; ¼ Hp, 250 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc. B UL/CSA Rating: 20 A, 125, 250 or 480 Vac; 10 A, 125 Vac “L”; 1 Hp, 125 Vac; 2 Hp, 250 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc. C UL/CSA Rating: D UL/CSA Rating: 10 A, 125 or 250 Vac; 0.3 A, 125 Vdc; 0.15 A, 250 Vdc . 10 A, 125, 250 or 480 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc. E UL Rating: Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) 1 A, 125 Vac. DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) Side rotary actuated switches OPTIONS No lever Note: Levers are ordered separately (see pages 71-73 for details) Operating force max. (OF): Electrical rating A Electrical rating B Pretravel max. (PT): Overtravel max. (OT): Electrical rating A Electrical rating B Differential travel max. (DT): Electrical rating A Electrical rating B ACTUATION CW CCW CW 60 www.honeywell.com/sensing CONTACT SPDT SPDT SPDT 0,22 N m [31.25 in oz] 3,34 N to 8,90 N [0.75 lb to 2.0 lb] 5,56 mm [0.219 in] 8° 90° 25° 0,18 mm [0.007 in] 0.25° 0,3 mm [0.012 in] 4° ELECTRICAL RATING A A B CAT. LISTING EX-AR20 EX-AR230 EXA-AR20 HAZARDOUS LOCATION SWITCHES Roller lever DPDT, Preleaded with 0,91 m [3 ft] leadwire Roller material: Operating force max. (OF): Electrical rating A Clockwise (CW) Counter clockwise (CCW) Electrical rating B Pretravel max. (PT): Electrical rating A, B Clockwise (CW) Counter clockwise (CCW) Overtravel max. (OT): Electrical rating A Clockwise (CW) Counter clockwise (CCW) Electrical rating B Differential travel max. (DT): Electrical rating A Electrical rating B ACTUATION CW CCW CW/Class 1 Group B CCW/Class 1 Group B CW/High temperature CW CW/No mounting bracket CW/Nylon roller CW/No mounting bracket *No ATEX approval CONTACT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT 5,56 mm [0.219 in] 8° 1,65 mm [0.065 in] 3.5° 90° 25° 25° ACTUATION CW CONTACT SPDT ELECTRICAL RATING C C CONTACT DPDT DPDT CAT. LISTING EXD-AR-3 EXD-AR30-3 Operating force max. (OF): Clockwise (CW) Counter clockwise (CCW) Pretravel max. (PT): Clockwise (CW) Counter clockwise (CCW) Overtravel max. (OT): Differential travel max. (DT): Sealing: ACTUATION CW/3,2 m [10.5 ft] leadwire CCW/0,91 m [3 ft] leadwire CW/0,91 m [3 ft] leadwire CONTACT SPDT SPDT SPDT 2,22 N to 6,67 N [0.5 lb to 1.5 lb] 11,1 N [2.5 lb] 5,56 mm [0.219 in] 8° 1,65 N [0.065 in] 3.5° 25° 0,64 mm [0.025 in] NEMA Class 1 Group B ELECTRICAL RATING E E E CAT. LISTING EXH-AR3 EXH-AR33 EXH-AR7 0,18 mm [0.007 in] 0.25° 0,3 mm [0.012 in] 4° ELECTRICAL RATING A A A A A B B A A CAT. LISTING EX-AR EX-AR30 EX-AR800 EX-AR830 EX-AR400* EXA-AR EXA-AR62 EX-AR182 EX-AR141 0,56 N [2 oz] ELECTRICAL RATING A CAT. LISTING EX-AR16 Maintained contact Operating force max. (OF): Pretravel max. (PT): Overtravel max. (OT): ACTUATION CW CCW Hermetically sealed 2,22 N to 5,56 N [0.5 lb to 1.25 lb] 11,1 N [2.5 lb] 3,34 N to 8,90 N [0.75 lb to 2.0 lb] Operating force max. (OF): CONTACT SPDT 2,22 N to 6,67 N [0.5 lb to 1.5 lb] 12,2 N [2.75 lb] 6,35 mm [0.250 in] 25° 2,77 mm [0.109 in] 4° NEMA Class 1 Group B Bronze CW or CCW actuation, no return spring, low operating force ACTUATION CW/CCW/No mounting bracket Operating force max. (OF): Clockwise (CW) Counter clockwise (CCW) Pretravel max. (PT): Overtravel max. (OT): Differential travel max. (DT): Sealing: 3,34 N [0.75 lb] 5,56 mm [0.219 in] 8° 90° ELECTRICAL RATING A CAT. LISTING EX-XR3 2 Conduit openings Operating force max. (OF): Electrical rating A Electrical rating B Electrical rating C Pretravel max. (PT): Electrical rating A, B Electrical rating C Overtravel max. (OT): Electrical rating A Electrical rating B, C Differential travel max. (DT): Electrical rating A Electrical rating B Electrical rating C CONTACT DPDT SPDT SPDT www.honeywell.com/sensing 2,22 N to 5,56 N [0.5 lb to 1.25 lb] 3,61 N to 8,90 N [0.8 lb to 2 lb] 2,22 N to 6,67 N [0.5 lb to 1.5 lb] 5,56 mm [0.219 in] 8° 6,35 mm [0.250 in] 90° 25° 0,18 mm [0.007 in] 0.25° 0,3 mm [0.012 in] 0.5° 2,77 mm [0.109 in] 4° ELECTRICAL RATING C B A CAT. LISTING 4EX1-3 2EX1 1EX1 61 HAZARDOUS LOCATION SWITCHES EX Series Side rotary actuated switches (continued) Overtravel plunger actuated switches Cross roller lever, rotated 90° Top pin plunger Operating force max. (OF): Pretravel max. (PT): Overtravel max. (OT Differential travel max. (DT): CW CONTACT SPDT 2,22 N to 5,56 N [0.5 lb to 1.25 lb] 5,56 mm [0.219 in] 8° 90° 0,18 mm [0.007 in] 0.25° ELECTRICAL RATING A CAT. LISTING EX-CR Rod lever OPTIONS Operating force max. (OF): Electrical rating A, C Electrical rating B Pretravel max. (PT): Electrical rating A Electrical rating B Electrical rating C Overtravel min. (OT): Electrical rating A Electrical rating B Electrical rating C Differential travel max. (DT): Electrical rating A Electrical rating B Electrical rating C No mounting bracket High temperature Low OF *No ATEX approval Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): CW/No mounting bracket 62 CONTACT SPDT 0,56 N [2 oz] 18° 40° ELECTRICAL RATING A CAT. LISTING EX-AR1613 CONTACT SPDT SPDT SPDT SPDT 13,34 N [3.0 lb] 8,90 N [2 lb] 1,98 mm [0.078 in] 1,27 mm [0.050 in] 3,96 mm [0.156 in] 4,78 mm [0.188 in] 3,18 mm [0.125 in] 3,48 mm [0.141 in] 0,10 mm [0.004 in] 0,23 mm [0.009 in] 1,52 mm [0.060 in] ELECTRICAL RATING A A A B CAT. LISTING EX-Q EX-Q62 EX-Q400* EXA-Q Sealing NEMA Class 1 Group B CONTACT SPDT Preleaded with 0,91 m [3 ft] leadwire DPDT www.honeywell.com/sensing ELECTRICAL RATING A C CAT. LISTING EX-Q800 EXD-Q-3 HAZARDOUS LOCATION SWITCHES Boot sealed Operating force max. (OF): Electrical rating D Electrical rating B Pretravel max. (PT): Electrical rating D Electrical rating B Overtravel min. (OT): Electrical rating D Electrical rating B Differential travel max. (DT): Electrical rating D Electrical rating B Class 1 Group B CONTACT SPDT SPDT 13,34 N [3.0 lb] 15,57 N [3.5 lb] 1,98 mm [0.078 in] 2,77 mm [0.109 in] 4,78 mm [0.188 in] 3,18 mm [0.125 in] 0,10 mm [0.004 in] 0,23 mm [0.009 in] ELECTRICAL RATING D B CAT. LISTING EX-N15 EXA-N Manually actuated Operating force max. (OF): CONTACT SPDT 11,1 N [2.5 lb] ELECTRICAL RATING A CAT. LISTING EX-AR50 www.honeywell.com/sensing 63 HAZARDOUS LOCATION SWITCHES CX Series Weather Sealed Explosion Proof Switches X ATEoved r p p a CX switches, as are the LSX/BX Series, are built especially for outdoor use in hazardous atmospheres. These enclosures are constructed to withstand the pressure of an internal explosion. O-ring seals make the enclosure weatherproof but are outside of required flame paths so explosion proof requirements are maintained. As factory assembled, all basic switches operate on clockwise and counterclockwise rotation. The actuating mechanism can be field adjusted for CW or CCW operation only. Analog output, 4 mA to 20 mA, is available. Basic switches operate nearly simultaneously in multiple switch devices. Shafts of devices without shaft restoring force can be rotated through 360°. Sealing: UL listed CSA certified Operating temperature: Approvals: Housing: Conduit: Contacts: Actuators IP66, 67; NEMA 1, 3, 4, 4X, 6, 6P, 7, 9 and 13 Class I, Div. 1, Groups B (16CX, 24CX, 26CX, and 84CX only), C and D; and Class II, Div. 1, Groups E, F and G Class I, Div. 1, Groups B (16CX, 24CX, 26CX, and 84CX only), C and D; and Class II, Groups E, F and G -25 °C to 85 °C [-13 °F to 185 °F] UL, CSA CX-E only ATEX EExd IIC T6 Category II 2 GD Aluminium 80CX Bronze ¾ in - 14NPT A, C, D Silver F Gold Electrical Ratings: A UL/CSA Rating: L96 15 A, 120, 240 or 480 Vac, ind. and res 1 /8 Hp, 120 Vac; ¼ Hp, 240 Vac 0.5 A, 125 Vdc, 0.25 A, 250 Vdc, res C UL/CSA Rating: L59 10 A, 120 or 240 Vax, ind. and res 0.3 A, 125 Vdc, 0.15 A, 250 Vdc, res D UL/CSA Rating: L22 1 A, 120 Vax, ind. and res F UL/CSA Rating: L22 1 A, 125 Vac G Analog Current Output (4 mA to 20 mA) 12.5 Vdc to 40 Vdc Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) Analog position sensing specifications (Electrical rating “G”) Current output: Voltage compliance range: Maximum load resistance: Current signal output: Span: Null: 64 www.honeywell.com/sensing 4 mA to 20 mA 12.5 Vdc to 40 Vdc RL, Max., –V Supply - 12.5 20 mA 4 mA to 20 mA Adjustable from 15° to 90° of angular rotation 4 mA position may be set at any angular position HAZARDOUS LOCATION SWITCHES Operating characteristics Basic Switch Type BZ BA DT Pretravel (max.)* 15° 15° 30° Differential Travel (max.) 10° 10° 25° Overtravel (min.)* 90° 90° 75° Operating Torque (max.) 11.1 in lb/1,25 N m * May be modified in field to suit application requirements. Note: Levers are ordered separately (see pages 71-73 for details) HS 30° 20° 75° Notes: Add the letter “A” to listings with side mounting holes tapped 5/16 (8). Example: 11CX2A Add the letter “B” to listings with thru mounting holes tapped 3/8-24 (4). Example: 11CX2B Add the letter “C” to listings for low temperature (-40 °C/°F) applications. Example: 11CX2C Add “D01” to specify a “direct-couple” listing with 3/8 in. dia by 3/4 in. long flatted shaft. Example: 11CX2-D01 Add the letter “E” to listings for European Atex approvals. Example: 11CX2E For Replacement Basic Switch Assemblies, change the first number in the listing to “9”. Example: 11CX2 becomes 91CX2 Short housing OPTIONS HOUSING SIZE Short Short Short Short Short Short BASIC SWITCHES BZ (2) BZ (2) BZ (2) BZ (2) BZ (2) BZ (2) CONTACT SHAFT RESTORING FORCE TO CENTRE With Without With Without With Without CAT. LISTING SPDT SPDT SPDT SPDT SPDT SPDT ELECTRICAL RATING A A A A F F Standard Standard BZ (4) BZ (4) SPDT SPDT A A With Without 21CX4 21CX14 11CX2 11CX12 11CX2E 11CX12E 1172CX2 1172CX12 UL listed for Class I, Group B (hydrogen atmospheres) Standard housing HOUSING SIZE Standard Standard Short Short Standard BASIC SWITCHES DT (2) DT (2) HS (2) HS (2) HS (4) CONTACT DPDT DPDT SPDT SPDT SPDT ELECTRICAL RATING C C D D D SHAFT RESTORING FORCE TO CENTRE With Without With Without With CAT. LISTING SHAFT RESTORING FORCE TO CENTRE With Without Without With Without CAT. LISTING 24CX2 24CX12 16CX2 16CX12 26CX4 Analog output, 4 mA to 20 mA HOUSING SIZE Short Short Short Standard Standard BASIC SWITCHES None None None BZ (2) BZ (2) CONTACT N/A N/A N/A SPDT SPDT ELECTRICAL RATING G G G A, G A, G 18CX0 18CX10 18CX10E 281CX2 281CX12 Bronze housing for use in corrosive environments 80CX switches have rugged bronze housings which are resistant to salt water and other corrosive environments. They comply with the NEMA 4X requirement for protection against corrosion, in addition to NEMA enclosure standards met by other CX switches. O-ring seals make the enclosure weather-proof, but are outside of required flame paths, maintaining explosion-proof requirements. HOUSING SIZE Standard Standard Standard Standard BASIC SWITCHES BZ (2) BZ (4) BZ (4) DT (2) www.honeywell.com/sensing CONTACT SPDT SPDT SPDT DPDT ELECTRICAL RATING A A A C SHAFT RESTORING FORCE TO CENTRE With With Without With CAT. LISTING 81CX2 81CX4 81CX14 84CX2 65 HAZARDOUS LOCATION SWITCHES LSX/BX Series Weather sealed explosion proof switches BX X ATE LSX/BX Series weather sealed, explosion proof limit switches are for use either indoor or outdoors in hazardous atmospheres. They are completely sealed and designed for use in explosive gas/dust environments. LSX/BX products meet the sealing standards of NEMA 1, 3, 4, 6, 7, 9 and 13. BX products are also sealed to IP67 standard and are ATEX approved (see specifications below). All heads are field adjustable at 90° increments. Heads with side rotary actuators can be adjusted for clockwise and counter clockwise operation. d rove app Actuators Sealing: LSX NEMA 1, 3, 4, 6, 7 (Class 1, Division 1, Groups B, C, D), 9 (Class 2, Division 1, Groups E, F, G), 13 IP67, NEMA 1, 3, 4, 6, 7 (Class 1, Division 1, Groups B, C, D), 9 (Class 2, Division 1, Groups E, F, G), 13 BX Rotary actuated switches Approvals: LSX/BX UL, CSA* BX only EExd IIC T6 category II 2 GD, SIRA 00ATEX 1037X Contacts: Electrical ratings A, B Silver Electrical rating C Gold Switching options: SPDT DPDT Single Pole, Double Throw Double Pole, Double Throw Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO) Operating torque max.: SPDT Double Break DPDT Double Break * Applies only to listings with ½ in NPT or ¾ in NPT Electrical ratings 10 amps continuous carry. Circuits on any one pole must be the same polarity. ac Volts Pilot duty: 600 Vac, 720 VA A SPDT NEMA A600 B DPDT NEMA B600 C SPDT/DPDT Amps at 0.35 Power Factor Vac Make Break 120 60 6 240 30 3 480 15 1.5 600 12 1.2 120 30 3 240 15 1.5 480 7.5 0.75 600 6 0.60 250 Vac or 60 Vdc, 0.050 amp max. Standard Low Pretravel max. (PT): Standard Low Overtravel min. (OT): Standard Low Differential travel max. (DT): Standard SPDT Standard DPDT Low SPDT Low DPDT Note: Levers are ordered separately (see pages 71-73 for details) dc Volts Pilot duty: 240 Vdc, 30 watts A SPDT B DPDT C SPDT/DPDT 66 0,45 N m [4.0 in lb] 0,19 Nm [1.7 in lb] 15° 9° 60° 66° Make and Break Amps Vdc Inductive Resistive 120 0.25 0.8 240 0.15 0.4 120 0.25 0.8 240 0.15 0.4 250 Vac or 60 Vdc, 0.050 amp max. www.honeywell.com/sensing 5° 7° 3° 4° HAZARDOUS LOCATION SWITCHES OPTIONS Side rotary Maintained contact 39,6 1.56 50,8 2.00 Operating torque max.: Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): SPDT DPDT 19,0 0.75 25,4 1.00 31,9 1.25 LSX Operating temperature: 49,3 1.94 Maintained Maintained Maintained CONTACT SPDT DPDT DPDT -1 °C to 121 °C [30 °F to 250 °F] CONDUIT ½ in - 14NPT ¾ in - 14NPT ½ in - 14NPT ELECTRICAL RATING A B B CAT. LISTING LSXN3K LSXN4L LSXN7L BX (ATEX approved) LSX Operating temperature: Low DT 0,45 N m [4.0 in lb] 65° 20° 30° 35° CONTACT SPDT SPDT SPDT SPDT DPDT DPDT DPDT SPDT -12 °C to 121 °C [10 °F to 250 °F] CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT ½ in - 14NPT ¾ in - 14NPT 20 mm ½ in - 14NPT ½ in - 14NPT ELECTRICAL RATING A A A C B B B A CAT. LISTING LSXA3K LSX4A3K LSXA4K LSXA3E LSXA4L LSX4A4L LSXA7L LSXP3K Operating temperature: Maintained Maintained CONTACT SPDT DPDT -40 °C to 70 °C [ -40 °F to 158 °F] CONDUIT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B CAT. LISTING BXN3K BXN4L Top rotary BX (ATEX approved) Operating temperature: CONTACT SPDT SPDT DPDT -40 °C to 70 °C [ -40 °F to 158 °F] CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT ELECTRICAL RATING A A B CAT. LISTING BXA3K BX4A3K BXA4L LSX Operating temperature: Low DT/Low torque Low DT/Low torque Low torque Low torque CONTACT SPDT DPDT SPDT DPDT -1 °C to 121 °C [30 °F to 250 °F] CONDUIT ½ in - 14NPT ¾ in - 14NPT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B A B CAT. LISTING LSXH3K LSXH4L LSXR3K LSXR4L Low torque Low torque Low torque CONTACT SPDT SPDT DPDT -40 °C to 70 °C [ -40 °F to 158 °F] CONDUIT ½ in - 14NPT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A C C CAT. LISTING BXR3K BXR3E BXR4S 0,28 N m [2.5 in lb] 25° 100° 10° 12° LSX Operating temperature: BX (ATEX approved) Operating temperature: Operating torque max.: Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): SPDT DPDT CONTACT SPDT DPDT -1 °C to 121 °C [30 °F to 250 °F] CONDUIT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B CAT. LISTING LSXB3K LSXB4L Centre neutral Operating torque max. : Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 0,45 N m [4.0 in lb] 18° 57° 10° LSX Operating temperature: CONTACT DPDT DPDT -1 °C to 121 °C [30 °F to 250 °F] CONDUIT ¾ in - 14NPT 20 mm ELECTRICAL RATING B B CAT. LISTING LSXM4N LSX4M4N www.honeywell.com/sensing 67 HAZARDOUS LOCATION SWITCHES LSX/BX Series (continued) Plunger actuated switches BX X d ATpE rove ap Top plungers Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): SPDT DPDT 17,79 N [4 lb] 1,78 mm [0.07 in] 4,83 mm [0.19 in] 0,38 mm [0.015 in] 0,51 mm [0.02 in] OPTIONS Top pin plunger Top roller plunger Head can be set at 90° increments for cam or slide actuation Operating point: 58,5 mm ± 0,76 mm [2.305 in ± 0.03 in] Operating point: LSX Operating temperature: -12 °C to 93 °C [10 °F to 200 °F] LSX Operating temperature: CONTACT SPDT SPDT DPDT CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT ELECTRICAL RATING A A B CAT. LISTING LSXC3K LSX4C3K LSXC4L BX (ATEX approved) Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F] CONTACT SPDT DPDT DPDT ELECTRICAL RATING A B B CONDUIT 20 mm ¾ in - 14NPT 20 mm CAT. LISTING BX4C3K BXC4L BX4C4L CONTACT SPDT SPDT DPDT CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT CONTACT SPDT 68 CONDUIT ½ in - 14NPT -40 °C to 70 °C [ -40 °F to 158 °F] ELECTRICAL RATING A CONDUIT 20 mm 21,6 (0.85) 65,66 mm to 72,01 mm [2.585 in to 2.835 in] -12 °C to 93 °C [10 °F to 200 °F] ELECTRICAL RATING A CAT. LISTING LSXD3K LSX4D3K LSXD4L CONTACT SPDT LSX Operating temperature: ELECTRICAL RATING A A B Operating temperature: Min. operating point Max. 65,7 operating point (2,59) 72,0 (2,83) Operating point: -12 °C to 93 °C [10 °F to 200 °F] BX (ATEX approved) Top pin plunger, adjustable 7,9 (0.31) 68,6 mm ± 1.00 mm [2.700 in ± 0.04 in] CAT. LISTING LSXV3K www.honeywell.com/sensing CAT. LISTING BX4D3K HAZARDOUS LOCATION SWITCHES Wobble actuated switches OPTIONS Side plungers Plastic rod Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 26,69 N [6 lb] 2,54 mm [0.10 in] 4,83 mm [0.19 in] 1,14 mm [0.045] OPTIONS Side pin plunger 39,6 1.56 50,8 2.00 19,0 0.75 25,4 1.00 49,3 1.94 Operating point: 33,0 mm [1.30 in] LSX Operating temperature: CONTACT SPDT DPDT CONDUIT ½ in - 14NPT ¾ in - 14NPT -12 °C to 93 °C [10 °F to 200 °F] ELECTRICAL RATING A B CAT. LISTING LSXE3K LSXE4L Operating force max. (OF): Pretravel max. (PT): LSX Operating temperature: CONTACT SPDT DPDT Side roller plunger 2,78 N [10 oz] 25,4 mm [1.0 in] CONDUIT ½ in - 14NPT ¾ in - 14NPT -12 °C to 93 °C [10 °F to 200 °F] ELECTRICAL RATING A B CAT. LISTING LSXJ3K-7A LSXJ4L-7A Roller may be set in vertical or horizontal position for cam or slide actuation Cat whisker Operating point: 44,1 mm [1.735 in] LSX Operating temperature: CONTACT SPDT CONDUIT ½ in - 14NPT -12 °C to 93 °C [10 °F to 200 °F] ELECTRICAL RATING A CAT. LISTING LSXF3K BX (ATEX approved) Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F] CONTACT SPDT ELECTRICAL RATING A CONDUIT ½ in - 14NPT CAT. LISTING BXF3K Operating force max. (OF): Pretravel max. (PT): 1,39 N [5 oz] 50,8 mm [2.0 in] LSX Operating temperature: -12 °C to 93 °C [10 °F to 200 °F][10 °F to 200 °F] CONTACT SPDT CONDUIT ½ in - 14NPT www.honeywell.com/sensing ELECTRICAL RATING A CAT. LISTING LSXK3K-8A 69 70 www.honeywell.com/sensing LEVERS Levers CAT. LISTING ROLLER MATERIAL Separate levers must be ordered with side rotary types. The table provides a cross reference between product families and the lever order/reference numbers. The following pages describe the levers. Illustrations are for reference only. Exact mounting drawings and dimensions are available from your local sales office or from the website below. 6PA57 6PA63 6PA69 6PA80 6PA82 6PA102 6PA144 GLZ51A GLZ51B GLZ52A GLZ52B GLZ54J GLZ55B LSZ51 LSZ51A LSZ51B LSZ51C LSZ51D LSZ51W LSZ51Y LSZ52 LSZ52A LSZ52B LSZ52C LSZ52D LSZ52J LSZ52K LSZ52M LSZ52N LSZ52W LSZ52Y LSZ53A LSZ53B LSZ53D LSZ53E LSZ53P LSZ53S LSZ53U LSZ54 LSZ54M LSZ54N LSZ54R LSZ54V LSZ55 LSZ55A LSZ55B LSZ55C LSZ55D LSZ55W LSZ55Y LSZ61 LSZ67AA LSZ68 6PA5-EX 6PA127-EX 6PA130-EX 6PA131-EX 6PA136-EX 6PA138-EX 6PA142-EX 6PA204-EX Aluminium Stainless steel Spring rod Steel Steel Nylon Ball bearing Nylon Steel Nylon Steel Aluminium Steel N/A Nylon Steel Nylon Steel Rubber Rubber N/A Nylon Steel Nylon Steel Nylon Nylon Nylon Nylon Rubber Rubber Nylon Steel Steel Nylon Steel Nylon Steel N/A Aluminium Stainless steel Spring wire Cable N/A Nylon Steel Nylon Steel Rubber Rubber Nylatron Rubber Delrin Bronze Nylon Bronze Bronze Aluminium Nylon Bronze Nylon Levers lock in any position, 360° around the shaft. Rollers may be mounted on the front or back of the lever. All levers are supplied with cap screws. Explosion proof switches Because of explosion proof requirements, only nylon rollers or other non sparking material should be selected. BX/LSX, CX and EX plunger and cat whisker types are of non sparking material. Do not mix or substitute. Specification (unless stated otherwise) Lever radius/length: Roller Diameter: Roller Width: -EX 1.5 in [38,1 0.75 in [19,1 0.25 in [6,35 0.312 in [7,92 Note: Not all levers are compatible with all switches mm] mm] mm] mm] GLA LIMIT SWITCH SERIES HDLS LS2 LS EXPLOSION PROOF SERIES BX/LSX CX EX ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ Stainless steel levers LS2Z51A LS2Z51B LS2Z52A LS2Z52B LS2Z54N Nylon Steel Nylon Steel Steel ™ ™ ™ ™ ™ www.honeywell.com/sensing ™ ™ ™ ™ ™ ™ ™ 71 LEVERS OPTIONS * denotes lever suitable for Explosion Proof Series switches One way roller lever Standard fixed lever MOUNTED ON Without roller Nylon roller Metal roller Nylon roller Metal roller Nylon roller Metal roller Bronze roller Nylon roller Ball bearing roller Front Front Back Back Front Front Front Front Front CAT. LISTING LSZ51* LSZ51A* LSZ51B LSZ51C* LSZ51D GLZ51A GLZ51B 6PA5-EX* 6PA127-EX* 6PA144 Offset fixed lever RADIUS/LENGTH Bronze roller, clockwise RADIUS/LENGTH CAT. LISTING 1.56 in [39,6 mm] 6PA130-EX* Back Back Front Front Front Hub only Aluminium rod Stainless steel rod Aluminium, spring only Aluminium, flexible cable Aluminium rod Stainless steel rod Aluminium rod CAT. LISTING LSZ54* 5.5 in [139,7 mm] LSZ54M* 13.0 in [330,2 mm] LSZ54N 12.0 in [305 mm] LSZ54R 4.8 in [122 mm] LSZ54V 7.9 in [200 mm] GLZ54J 13.0 in [330,2 mm] 6PA63 5.3 in [134,1 mm] 6PA136-EX* Bronze roller, counter clockwise 1.56 in [39,6 mm] 6PA142-EX* Perpendicular (cross) roller lever MOUNTED ON Without roller Nylon roller Metal roller Nylon roller Metal roller Metal roller Adjustable rod CAT. LISTING LSZ55* LSZ55A* LSZ55B LSZ55C* LSZ55D GLZ55B RADIUS/LENGTH Bronze roller mm] 6PA131-EX* Adjustable rod, nylon roller CAT. LISTING 1.81 in [46,0 Aluminium rod, nylon roler RADIUS/LENGTH CAT. LISTING 12.5 in [317,5 mm] 6PA204-EX* Adjustable lever Yoke lever Operating radius/length: 1.5 in to 3.5 in [38,1 mm to 88,9 mm] -EX 1.69 in to 3.0 in [42,9 mm to 76,2 mm] Adjustable lever, without roller Nylon roller Metal roller Nylon roller Metal roller Nylon roller, Ø 1.0 in [25,4] x 0.5 in [12,7 mm] Nylon roller, Ø 1.5 in [38,1] Nylon roller, Ø 2.0 in [50,8] Nylon roller, 0.5 in wide [12,7 mm] Nylon roller Metal roller Nylon roller, Ø 1.0 in [25,4] x 0.5 in [12,7 mm] MOUNTED ON CAT. LISTING LSZ52 Back LSZ52A* Back LSZ52B Front LSZ52C* Front LSZ52D Front Front Front Front Back Back LSZ52J* LSZ52K* LSZ52M* LSZ52N* GLZ52A GLZ52B Front 6PA138-EX* Nylon roller Metal roller Metal roller Nylon roller Metal roller Nylon roller Metal roller Metal roller Metal roller Nylon roller Note: 72 Spring rod MOUNTED ON Front/Back Front/Back Front/Front Back/Front Back/Back Back/Back Back/Front Front/Back Front/Front Front/Front CAT. LISTING LSZ53A LSZ53B LSZ53D LSZ53E* LSZ53P LSZ53S* LSZ53U 6PA80 6PA82 6PA102 Ø 0.25 in [6,35 mm] Ø 0.17 in [4,32 mm] Not all levers are compatible with all switches www.honeywell.com/sensing RADIUS/LENGTH 12.0 in [305 mm] 7.4 in [188 mm] CAT. LISTING LSZ68 6PA69 LEVERS * denotes lever suitable for Explosion Proof Series switches Stainless steel levers **Large rubber roller, adjustable lever Flexible loop Roller Diameter: Roller Width: 0.75 in [19,1 mm] 0.25 in [6,35 mm] OPTIONS Standard fixed lever Flexible loop RADIUS/LENGTH 6.0 in [152 mm] CAT. LISTING LSZ61 Ø 1.6 in X 0.50 in wide roller [40,6 mm X 12,7 mm] Ø 2 in X 0.50 in wide roller [50,8 mm X 12,7 mm] Hand operated button CAT. LISTING LSZ52W LSZ52Y Operating radius/length: Nylon roller Stainless steel roller 1.5 in [38,1 mm] MOUNTED ON Front Front CAT. LISTING LS2Z51A* LS2Z51B **Conveyor roller arm Adjustable lever Ø 1.5 in [38,1 mm] CAT. LISTING 6PA57 Operating radius/length: 6.78 in [172,2 mm] **Large rubber roller, fixed lever Plastic roller, 1.5 in Ø X 3.8 in long [38,1 mm X 96,5 mm] CAT. LISTING LSZ67AA Operating radius/length: 1.5 in to 3.5 in [38,1 mm to 88,9 mm] Nylon roller Stainless steel roller Ø 1.6 in X 0.50 in wide roller [40,6 mm X 12,7 mm] Ø 2 in X 0.50 in wide roller [50,8 mm X 12,7 mm] MOUNTED ON Back Back CAT. LISTING LS2Z52A* LS2Z52B CAT. LISTING LSZ51W LSZ51Y **Large rubber roller, fixed offset lever NOTICE ** Adjustable rod Large rubber rollers and conveyor roller arm Because of the lever’s mass, the limit switch should be mounted with the lever facing down. This will enable gravity to help restore the switch to the free position. Operating radius/length: 13 in [330,2 mm] CAT. LISTING LS2Z54N Ø 1.6 in X 0.50 in wide roller [40,6 mm X 12,7 mm] Ø 2 in X 0.50 in wide roller [50,8 mm X 12,7 mm] CAT. LISTING LSZ55W LSZ55Y Note: Not all levers are compatible with all switches www.honeywell.com/sensing 73 POWER RELAYS SZR-MY Series Power Relay 2,6 [0.10] Solder/Plug-In Terminal, DPDT 8 - O 1,2 [0.05] x 3 Holes Current rating (SZR-MY2): Current rating (SZR-MY4): Contact resistance: Contact material: Agency approvals: Operate time: Release time: Ambient temperature: Ambient humidity: Switching options: 5A 3A 50 mOhm max. Fine silver UL, CE, CSA 20 ms max. 20 ms max. -25 °C to 75 °C [-13 °F to 167 °F] 45% RH to 85% RH DPDT, 4PDT 6,3 [0.25] SZR-MY Series relays have a small package design for multiple application needs. Relays are available in two configurations: DPDT with a 5 A load and 4PDT with a 3 A load. One standard and three options are available: LED indicator, internal surge protection diode, and LED indicator/diode protection. Max. 21,5 [0.85] 0,5 [0.02] Max. 36,0 [1.42] Max. 28,0 [1.10] 0,5 [0.02] SZR-MY Series general-purpose power relays are designed for a wide range of potential applications including power, as well as logic control, for factory machines and control panels. 6,0 [0.24] Standard COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/5 amp 250 Vac/5 amp 125 Vdc/1 amp 125 Vdc/1 amp CAT. LISTING SZR-MY2-1-AC110-120V SZR-MY2-1-AC220V SZR-MY2-1-DC12V SZR-MY2-1-DC24V MAX. CONTACT RATING 250 Vac/5 amp 250 Vac/5 amp 125 Vdc/1 amp 125 Vdc/1 amp CAT. LISTING SZR-MY2-N1-AC110-120V SZR-MY2-N1-AC220V SZR-MY2-N1-DC12V SZR-MY2-N1-DC24V MAX. CONTACT RATING 125 Vdc/1 amp CAT. LISTING SZR-MY2-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection MY2 Series COIL INPUT VOLTAGE 24 Vdc OPTIONS LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc 3,3 [0.13] 1,0 [0.04] Standard, PCB Terminal, DPDT 6,3 [0.25] 0,5 [0.02] Max. 36,0 [1.42] COIL INPUT VOLTAGE 110/120 Vac 220/240 Vac 24 Vdc 74 Max. 28,0 [1.10] 0,5 [0.02] 3,5 [0.14] Max. 21,5 [0.85] 6,0 [0.24] MAX. CONTACT RATING 250 Vac/5 amp 250 Vac/5 amp 125 Vdc/1 amp CAT. LISTING SZR-MY2-1P-AC110-120V SZR-MY2-1P-AC220V-240V SZR-MY2-1P-DC24V www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/1 amp CAT. LISTING SZR-MY2-X1-DC24V POWER RELAYS Solder/Plug-In Terminal, 4PDT MY4 Series 2,6 [0.10] OPTIONS 14 - O 1.2 [0.05] x 3 Holes 6,3 [0.25] Max. 28,0 [1.10] 0,5 [0.02] 6,3 [0.25] 3,5 [0.14] 0,5 [0.02] Max. 36,0 [1.42] COIL INPUT VOLTAGE 110/120 Vac 220/240 Vac 24 Vdc Max. 21,5 [0.85] 6,0 [0.24] Standard 5,0 [0.20] MAX. CONTACT RATING 250 Vac/3 amp 250 Vac/3 amp 125 Vdc/0.6 amp Max. 21,5 [0.85] 0,5 [0.02] Max. 36,0 [1.42] Max. 28,0 [1.10] 0,5 [0.02] 3,3 [0.13] 1,0 [0.04] Standard, PCB Terminal, 4PDT CAT. LISTING SZR-MY4-1P-AC110-120V SZR-MY4-1P-AC220V-240V SZR-MY4-1P-DC24V COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/3 amp 250 Vac/3 amp 125 Vdc/0.6 amp 125 Vdc/0.6 amp CAT. LISTING SZR-MY4-1-AC110-120V SZR-MY4-1-AC220V SZR-MY4-1-DC12V SZR-MY4-1-DC24V MAX. CONTACT RATING 250 Vac/3 amp 250 Vac/3 amp 125 Vdc/0.6 amp 125 Vdc/0.6 amp CAT. LISTING SZR-MY4-N1-AC110-120V SZR-MY4-N1-AC220V SZR-MY4-N1-DC12V SZR-MY4-N1-DC24V MAX. CONTACT RATING 125 Vdc/0.6 amp CAT. LISTING SZR-MY4-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection COIL INPUT VOLTAGE 24 Vdc LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/0.6 amp CAT. LISTING SZR-MY4-X1-DC24V 75 POWER RELAYS SZR-LY Series Power Relay LY2 Series OPTIONS Operate time: Release time: Ambient temperature: Ambient humidity: Switching options: 10 A 50 mOhm max. Silver cadium oxide UL, CE, CSA 18,000 operations/hour (mechanical) 1,800 operations/hour (electrical) 25 ms max. 25 ms max. -25 °C to 70 °C [-13 °F to 158 °F] 45% RH to 85% RH DPDT, 4PDT Solder/Plug-In Terminal, DPDT 14 - O 3,0 [0.12] 3,0 [0.12] Max. 36,0 [1.42] 6,4 [0.26] Max. 21,5 [0.85] Standard COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp CAT. LISTING SZR-LY2-1-AC110-120V SZR-LY2-1-AC220V SZR-LY2-1-DC12V SZR-LY2-1-DC24V MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp CAT. LISTING SZR-LY2-N1-AC110-120V SZR-LY2-N1-AC220V SZR-LY2-N1-DC12V SZR-LY2-N1-DC24V MAX. CONTACT RATING 125 Vdc/2 amp CAT. LISTING SZR-LY2-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection COIL INPUT VOLTAGE 24 Vdc LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc 76 Max. 28,0 [1.10] CAT. LISTING SZR-LY2-1P-AC110-120V SZR-LY2-1P-DC24V www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/ 2 amp CAT. LISTING SZR-LY2-X1-DC24V Max. 28,0 [1.10] Current rating: Contact resistance: Contact material: Agency approvals: Operating frequency: MAX. CONTACT RATING 250 Vac/10 amp 125 Vdc/2 amp 5,75 [0.23] One standard and three options are available: LED indicator, internal surge protection diode, and LED indicator/diode protection. COIL INPUT VOLTAGE 110/120 Vac 24 Vdc Max. 21,5 [0.85] 4,5 [0.18] 5,0 [0.20] SZR-LY Series relays break 10 A loads are often ideal for control panels that require stable and reliable relays. 1,0 [0.04] Max. 36,0 [1.42] 0,5 [0.02] SZR-LY Series general-purpose power relays are designed for a wide range of potential applications including power, as well as logic control, for factory machines and control panels. 5,75 [0.23] 2,0 [0.08] 0,5 [0.02] Standard, PCB Terminal, DPDT POWER RELAYS LY4 Series OPTIONS Solder/Plug-In Terminal, 4PDT 1,0 [0.04] Max. 36,0 [1.42] Max. 41,5 [1.63] 4,5 [0.18] Max. 28,0 [1.10] 14 - O 3.0 Holes 5,0 [0.20] 2,0 [0.08] Max. 28,0 [1.10] 0,5 [0.02] 0,5 [0.02] Standard, PCB Terminal, 4PDT Max. 36,0 [1.42] 3,0 [0.12] 6,4 [0.25] Max. 41,5 [1.63] Standard COIL INPUT VOLTAGE 110/120 Vac 220/240 Vac 24 Vdc MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp CAT. LISTING SZR-LY4-1P-AC110-120V SZR-LY4-1P-AC220V-240V SZR-LY4-1P-DC24V COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp CAT. LISTING SZR-LY4-1-AC110-120V SZR-LY4-1-AC220V SZR-LY4-1-DC12V SZR-LY4-1-DC24V MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp CAT. LISTING SZR-LY4-N1-AC110-120V SZR-LY4-N1-AC220V SZR-LY4-N1-DC12V SZR-LY4-N1-DC24V MAX. CONTACT RATING 125 Vdc/2 amp CAT. LISTING SZR-LY4-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection COIL INPUT VOLTAGE 24 Vdc LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/2 amp CAT. LISTING SZR-LY4-X1-DC24V 77 POWER RELAYS MY2 Series Socket LY2 Series Socket 22,0 [0.87] 3,9 [0.15] 15,6 [0.61] 30,0 [1.18] 25,0 [0.99] 4,2 [0.17] 2 - M4 2 - O 4,5 [0.18] Holes 2,5 [0.10] 26,0 [1.02] 14,5 [0.57] 30,0 [1.18] Max. 61,0 [2.40] Max. 61,0 [2.40] POLES 2 CAT. LISTING SZX-SMF-08N 4,5 [0.18] 2-M3 or 2-M4 2 - O 6,0 [0.24] 7,0 [0.28] 14-M3.5x8 3,4 [0.13] 2-M4 68,0 [2.68] 62,0 ± 0,1 [2.44 ± .004] 26,0 [1.02] 35,2 [1.39] 15,6 [0.61] 45,0 [1.77] 3,9 [0.15] 4,2 [0.17] CAT. LISTING SZX-SLF-08N LY4 Series Socket 6,0 [0.24] 62,0 [2.44] POLES 2 35,5 [1.40] MY4 Series Socket TYPE Rail socket Max. 78,5 [3.09] TYPE Rail socket 3,0 [0.12] 25,0 [0.99] 2 - O 4,5 [0.18] Holes 36,0 ± 0,2 [1.42 ± 0.008] 69,0 ± 0,3 [2.72 ± 0.01] 3,0 [0.12] 2 - O 4,5 [0.18] Holes 18,0 [0.70] 25,0 ± 0,2 [0.99 ± .008] 47,0 [1.85] 35,2 [1.39] 62,0 ± 0,1 [2.44 ± .004] 45,0 [1.77] 4,2 [0.17] 62,0 [2.44] 2-M3 or 2-M4 26,0 [1.02] 19,0 [0.75] 8,0 [0.31] 26,0 [1.02] 67,0 [2.64] 6,0 [0.24] 18,0 [0.70] 26,0 [1.02] 30,0 [1.18] 8,0 [0.31] Max. 45,5 [1.79] 25,0 [0.99] Max. 61,0 [2.40] Max. 66,0 [2.60] Max. 30,0 [1.18] TYPE Rail socket 78 POLES 4 CAT. LISTING SZX-SMF-14N TYPE Rail socket www.honeywell.com/sensing POLES 4 CAT. LISTING SZX-SLF-14 SAFETY SWITCHES Electromechanical Safety Switches Honeywell is a worldwide leader in advanced switching and sensing technology - especially in the area of industrial safety. We offer both electromechanical safety switches and electronic safety sensors as well as safety control modules for safety applications in all categories of risk. Our diverse product line can help customers meet all of their machine safety needs. Honeywell products meet or exceed European machine safety standards and have been approved (CE, INRS) for use in Europe for more than 25 years. As North America moves toward harmonizing with global standards, machine builders and users can confidently turn to Honeywell for compliant machine safety solutions. Our products are designed to meet all applicable OSHA and ANSI standards. Refer to pages 6 and 7 for more information about degrees of protection and electrical ratings. Protective Guarding Cable Pull Switches Protective guarding around a dangerous machine can be achieved with tamper-resistant safety switches. Safety switches incorporate positive opening operation such that even a welded contact will be mechanically broken and a stop signaled. These switches monitor the position of moveable guards and doors, which are used to safeguard access to equipment and provide protection from ejected pieces, chips, projectiles or oil. These safeguards require a relatively low investment and can provide reliable protection if they are regularly checked and maintained. Cable-pull limit switches serve as a readily accessible means of emergency stop for applications. These cable-pull devices are visible, accessible and easy to use and are designed to immediately open the emergency stop circuit when activated. ! WARNING IMPROPER INSTALLATION • Consult with local safety agencies and their requirements • when designing a machine-control link, interface and all control elements that affect safety. Strictly adhere to all installation instructions. Failure to comply with these instructions could result in death or serious injury. www.honeywell.com/sensing 79 SAFETY SWITCHES Selection Guide for Electromechanical Safety Switches Housing Material Approvals Sealing Dimensions Actuator Electrical Rating Operating Temperature To CCC UL Metal CSA Plastic CE From IEC IP NEMA (USA) Height x Width x Depth mm [in] °C [°F] 1, 12, 13 92,2 x 30,5 x 30,5 [3.63 x 1.20 x 1.20] Straight or 90° key AC15 A600, DC13 Q300 -25 [-13] 85 [185] GKN 67 1, 12, 13 4 (indoor use only) 90,0 x 40,0 x 33,0 [3.55 x 1.57 x 1.30] Straight or 90° key AC15 A600, DC13 Q300 -25 [-13] 85 [185] 67 1, 12, 13 69,4 x 34,0 x 16,0 [2.73 x 1.34 x 0.63] AC15, DC13 A300 -25 [-13] 85 [185] 66 1, 4, 12, 13 -25 [-13] 85 [185] GSC GKE 66 GKM Series Straight or 90° key AC15, DC13 A300 GSD 66 1, 12, 13 GSE 66 1, 4, 12, 13 83,0 x 65,0 x 30,0 [3.27 x 2.56 x 1.18] GK 67 1, 4, 12, 13 121,6 x 42,0 x 42,6 [4.79 x 1.65 x 1.68] Straight, 90°, Spring key AC15, DC13 A600 -25 [-13] 85 [185] GKL/R 67 1, 4, 6P, 12, 13 149,0 x 110,0 x 48,8 [5.85 x 4.33 x 1.92] Straight, 90°, Spring key AC15, DC13 A600 -25 [-13] 85 [185] 1CPS 67 1, 4, 12, 13 99,1 x 276,2 x 65,2 [3.9 x 10.87 x 2.57] Linear AC15, DC13 A600 -40 [-40] 85 [185] 2CPS GSS 83,0 x 30,5 x 30,0 [3.27 x 1.2 x 1.18] 67 1, 4, 12, 13 165,1 x 79,8 x 325,9 [6.5 x 3.14 x 12.75] Left and/or Right AC15, DC13 A600 -40 [-40] 85 [185] Hinge Straight or 90° GSS 80 AC15, DC13 A300 GK GKM www.honeywell.com/sensing AC15, DC13 A600 SAFETY SWITCHES Switching Options Special Features Termination Snap Action Make Before Break Break Before Make 1NC/ 2NC/ 1NC/ 2NC/ 1NC/ 1NC/ 1NC/ 2NC/ 2NC/ 3NC/ 1NC 2NC 4NC 1NO 2NO 1NO 1NO 2NO 1NO 1NO 2NO 1NO 2NO Page Number Slow Action Gold Contacts (Low Energy Options) Conduit 93 Conduit 96 M12 or Cable Daisy chain capability 82 85 Conduit 85 86 Conduit 87 Conduit 89 Conduit Standard Integral LED option 93 High intensity multi-cluster LED 95 Conduit 2CPS GKL/GKR 1CPS www.honeywell.com/sensing 81 SAFETY SWITCHES GKM Series Global Miniature Safety Key Operated Switch Used alone as Category 1 safety components or, in conjunction with other safety switches and our complete range of safety relays, it is possible to construct comprehensive protection schemes with Category 2, 3 or 4 compliance. The preleaded versions are designed to allow rapid fit, easy cable routing and function testing which cut costs dramatically in OEM applications. Simple upgrade guarding solution for End User applications. Low energy basic switches are rated as follows: Operating Voltage Ue 1 Vdc to 60 Vdc or 1 Vac to 125 Vac Operating Current Ie 1 mA to 50 mA Example of catalog listing using a low energy basic switch - GKMA19 Mechanical life: Sealing: Operating temperature: Approvals: > 1 million IP66/67, EN 60529, NEMA 1, 12, 13 -25 °C to 85 °C [-13 °F to 185 °F] CE, UL, CSA AC15 B300 DC13 Q300 Contacts: Silver Low energy Gold plated Switching options: Slow action contacts 1 Normally Closed/1 Normally Open, Break Before Make 1NC/1NO, BBM - GKMF 1NC/1NO, BBM, low energy - GKMA, B, C, D 3 4 1 Brown Blue 3 2 1 White 2 3 2 4 Black 1 4 2 Normally Closed 2NC, low energy - GKMA, B, C, D 2NC - GKMF 3 2 4 3 2 1 Brown Blue 3 1 White 2 4 Black 1 4 Electrical ratings: Designation & Utilization Category AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 Of key slot 90˚ - Key shown in optional actuating positions 16 max. / 0.63 Body style 'B' 17,2 / 0.67 1,6 / 0.058 12,8 / 0.504 Key slot 22,0 / 0.866 10 max. / 0.30 2 X mounting holes for M4 or #8 screws. Counter bored both sides 08,3 X 4,5 deep. 0.366 0.177 82 www.honeywell.com/sensing 32 max. / 1.26 37,4 / 1.47 2,3 / 0.69 34 max. / 0.34 VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 SAFETY SWITCHES OPTIONS KEY STYLE Side exit cable Side exit M12 dc micro-change connector Straight key 45 / 1.77 2 + max. / 0.945 3,5 / 0.138 12,8 / 0.504 2,5 / 0.093 CABLE LENGTH 1m 1m 2m 2m 2m 2m 3m 3m 3m 3m CONTACT 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy CAT. LISTING GKMA17 GKMA19 GKMA23 GKMA26 GKMA27 GKMA29 GKMA33 GKMA36 GKMA37 GKMA39 Face 'A' 21,3 / 0.638 CONTACT 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy CAT. LISTING GKMC03 GKMC06 GKMC07 GKMC09 15 / 0.59 6,4 min. / 0.252 22 / 0.866 2 holes for M4 or #8 screws CAT. LISTING GKZ51M Stainless steel Bottom exit M12 dc micro-change connector 90° key Bottom exit cable 2 holes for M4 or #8 screws with 45˚ C' SK X 2,1 deep 0.083 14 max. / 0.55 Face 'A' CONTACT 1NC/1NO, BBM 2NC, low energy 1NC/1NO, BBM, low energy CABLE LENGTH 1m 1m 1m 1m 2m 2m 2m 2m 3m 3m 3m 3m CONTACT 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy CAT. LISTING GKMB13 GKMB16 GKMB17 GKMB19 GKMB23 GKMB26 GKMB27 GKMB29 GKMB33 GKMB36 GKMB37 GKMB39 CAT. LISTING GKMD03 GKMD07 GKMD09 22 / 0.866 6,4 min. / 0.252 Dual exit M12 dc micro-change connector 24 max. / 0.945 Stainless steel CONTACT 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 12,8 / 0.504 32 max. / 1.25 CAT. LISTING GKZ52M CAT. LISTING GKMF03 GKMF06 GKMF07 GKMF09 www.honeywell.com/sensing 83 SAFETY SWITCHES GSS Series Hinge Mount Safety Limit Switch The Hinge Mount Safety Limit Switch is designed for use on machine access doors as an alternative solution to key operated interlocks and safety limit switches. When the access door is opened, a follower pin (not supplied) slides down the slot in the actuator lever, forcing the actuator lever to rotate and positively open the NC safety circuit to shut off the machine. Closing the access door rotates the actuator lever to the reset position, closing the NC safety contacts. The Hinge Mount Safety Limit Switch minimizes alignment problems because it may be offsetmounted from the hinge point of the door. The tamper-resistant design and the positive opening contacts provide an enhanced level of safety over the conventional spring-driven limit switches often used to monitor door position. Low Energy Switching In today’s demanding age of low energy controls, electromechanical switches are frequently used to interface directly with safety relays, PLCs and other low energy devices. To accommodate this requirement GSS offers a new gold plated contact version of the standard basic switch. This improves reliability of switching at low currents and voltages by protecting the contact surfaces from contamination during operation or storage prior to use. Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain environmental conditions, e.g. in the presence of moisture. Low energy basic switches are rated as follows: Operating Voltage Ue 1 Vdc to 60 Vdc or 1 Vac to 125 Vac Operating Current Ie 1 mA to 50 mA Example of catalog listing using a low energy basic switch - GSCB33S2. Switching options: GSC/D Snap action contacts (1NC/1NO) GSE Slow action contacts (4NC) 11 13 21 14 22 Zb Slow action contacts (1NC/1NO) BBM 22 31 32 4Y 41 42 Slow action contacts (2NC/2NO) BBM 22 21 12 21 11 12 21 22 2Y, 2X Zb 13 14 Slow action contacts (2NC) 11 34 44 Slow action contacts (3NC/1NO) BBM 12 2Y 21 33 43 11 12 21 22 31 32 43 44 3Y, 1X 22 Electrical ratings: Designation & Utilization Category 84 AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 www.honeywell.com/sensing VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 SAFETY SWITCHES ACTUATED SWITCHES GSC Metal body GSD Plastic body EN 50047 Safety Standard Rotated 90° to the left from center 22 / 0.87 20 / 0.78 24,75 / 0.97 Rotated 90° to the right from center 104 / 4.09 70 / 2.76 45 / 1.77 3/ 0.12 180 MIN R 2,15 / 0.08 55 / 2.16 GSC - Metal body GSC - Metal body 30,5 / 1.20 14,5 / 0.57 3,5 / 0.138 30 / 1.18 CONTACT 1NC/1NO 1NC/1NO, BBM 2NC 2NC, low energy CONDUIT ½ in NPT ½ in NPT ½ in NPT 20 mm CAT. LISTING GSCA01S1 GSCA03S1 GSCA06S1 GSCC36S1 GSD - Plastic body conduit thread 19,8 / 0.78 ø 23 / ø 0.9 Mechanical life: Sealing: up to 1 million IP 66 (GSC) CONTACT 1NC/1NO, BBM 2NC 1NC/1NO, BBM 2NC 1NC/1NO CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm CAT. LISTING GSDA03S1 GSDA06S1 GSDB03S1 GSDB06S1 GSDC01S1 CONTACT 1NC/1NO 1NC/1NO, BBM 2NC 2NC, low energy CONDUIT ½ in NPT ½ in NPT ½ in NPT PG 13,5 CAT. LISTING GSCA01S3 GSCA03S3 GSCA06S3 GSCB36S3 GSD - Plastic body CONTACT 1NC/1NO, BBM 2NC 1NC/1NO, BBM 2NC 1NC/1NO CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm CAT. LISTING GSDA03S3 GSDA06S3 GSDB03S3 GSDB06S3 GSDC01S3 Rotated 90° either direction from center NEMA 1, 4, 12, 13 (GSD) Operating temperature: Approvals: NEMA 1, 12, 13 -25 °C to 85 °C [-13 °F to 185 °F] IEC/EN 60947-5-1 AC15 A300 DC13 Q300 UL, CSA 5,1 / 0.20 11,5 / 0.45 2/ 0.08 45 / 1.77 70 / 2.76 90 min. 90 min. 12,5 / 0.49 28 / 24,8 / 0.97 GSC - Metal body CONTACT 1NC/1NO 1NC/1NO, BBM 2NC 2NC, low energy CONDUIT ½ in NPT ½ in NPT ½ in NPT PG 13,5 CAT. LISTING GSCA01S2 GSCA03S2 GSCA06S2 GSCB36S2 GSD - Plastic body CONTACT 1NC/1NO, BBM 2NC 1NC/1NO, BBM 2NC 1NC/1NO CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm CAT. LISTING GSDA03S2 GSDA06S2 GSDB03S2 GSDB06S2 GSDC01S2 www.honeywell.com/sensing 85 SAFETY SWITCHES GSE EN 50047 Compatible Safety 3 Conduit Metal Standard 12,5 / 0.49 ACTUATED SWITCHES Rotated 90° to the left from center 42 / 1.65 40 / 1.57 22 / 0.87 20 / 0.79 24,75 / 0.97 104 / 4.09 70 / 2.76 45 / 1.77 3/ 0.12 R 2,15 / 0.08 60 / 2.37 13,75 / 0.54 12 / 0.47 30 / 1.18 2,5 / 0.1 52 / 2.05 57 / 2.24 4/ 0.16 65 / 2.56 CONTACT 2NC/2NO, BBM 3NC/1NO, BBM 4NC, low energy CONDUIT ½ in NPT ½ in NPT 20 mm CAT. LISTING GSEA44S1 GSEA46S1 GSEC41S1 conduit thread 23,8 / 0.94 ø 23 / ø 0.9 Rotated 90° either direction from center 5,1 / 0.20 Mechanical life: up to 1 million Sealing: IP 66, NEMA/UL 1, 4, 12, 13 Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F] Approvals: IEC/EN 60947-5-1 AC15 A300 DC13 Q300 UL, CSA 11,5 / 0.45 2/ 0.08 45 / 1.77 70 / 2.76 90 min. 90 min. 12,5 / 0.49 28 / CONTACT 2NC/2NO, BBM CONDUIT ½ in NPT 24,8 / 0.97 CAT. LISTING GSEA44S2 Rotated 90° to the right from center 180 CONTACT 2NC/2NO, BBM 86 MIN CONDUIT ½ in NPT CAT. LISTING GSEA44S3 www.honeywell.com/sensing SAFETY SWITCHES GK Series Dual Entry Key Operated Safety Interlock Switch The GK Series is designed specifically for use on machines where key removal brings the machine to an immediate safe condition. It provides enhanced operator safety when added to hinged or sliding guard doors, screens and protective covers on enclosures. The GK Series is especially well suited for large door applications, typically in the automotive plant floor environment. Its heavy duty construction withstands harsh industrial environments where rugged, long-term durability is required. Nearly 1000 options are available in a simple to understand part number tree. A safety lockout device is also available for use with the GK Series. The lockout device (GKZL2) is specifically designed to prevent a key from being inserted either manually, or by the access door being closed while maintenance personnel are working on the machine. When inserted, the lockout device can accommodate up to four padlocks to prevent unauthorised removal of the device. Mechanical life: up to 15 million Sealing: IP 67, NEMA/UL type 1, 4, 12,13 Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F] Approvals: CE, CSA, UL AC15 A300/A600 DC13 Q300 Contacts: Silver Low energy Gold Switching options: Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO) 13 Zb 21 13 14 11 12 23 24 21 22 14 22 Slow action contacts (1NC/1NO), BBM 22 21 Slow action contacts (2NC) 21 22 Zb 2Y Slow action contacts (2NC/2NO), BBM Slow action contacts (3NC/1NO) 13 12 11 14 11 12 11 12 21 22 21 22 31 32 2y,2x 13 14 23 24 3y,1x 43 44 Slow action contacts (4NC) 11 12 21 22 31 32 41 42 4y Designation & Utilization Category AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 www.honeywell.com/sensing VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 87 SAFETY SWITCHES Electrical ratings: GK Series (continued) Head orientation OPTIONS 42 / 1.65 Opening to front and top 32 / 1.26 31 / 1.22 45,7 1.80 121,6 / 4.79 Opening to right and top 8/ 0.32 9/ 0.35 35 / 1.38 60 / 2.36 82 / 3.23 75,9 / 2.99 42,6 / 1.68 ø 5,3 / 0.21 7,3 / 0.29 30 / 1.18 5,3 / 0.21 Standard CONDUIT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT PG 13,5 PG 13,5 PG 13,5 20 mm 20 mm 20 mm 20 mm 20 mm 20 mm 20 mm 20 mm CONTACT 1NC/1NO 1NC/1NO 1NC/1NO 4NC 2NC/2NO, BBM 2NC/2NO, BBM 3NC/1NO, BBM 3NC/1NO, BBM 2NC/NO 4NC, low energy 3NC/1NO, BBM, low energy 1NC/1NO, BBM 1NC/1NO, BBM 2NC 2NC/2NO, BBM 1NC/1NO, BBM 2NC 2NC/2NO, BBM 1NC/1NO 1NC/1NO 1NC/1NO 2NC/NO 4NC, low energy 3NC/1NO, BBM, low energy 2NC Single LED indicator KEY 90° Up-down None 90° Straight 90° Straight 90° Straight None None Straight 90° None Straight 90° 90° 90° Straight 90° None None None None None CAT. LISTING GKBA1L7 GKBA1L8-F11* GKBA1LX GKBA10L7 GKBA14L6 GKBA14L7 GKBA16L6 GKBA16L7 GKBA2L6 GKBA30LX GKBA36LX GKBA3L6 GKBA3L7 GKBA6LX GKBB14L6 GKBB3L7 GKBB6L7 GKBC14L7 GKBC1L6 GKBC1L7 GKBC1LX GKBC2LX GKBC30LX GKBC36LX GKBC6LX Single LED indicator CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM 1/2 NPT 1NC/1NO KEY Straight 90° None None Straight Straight 90° Side-side None None None None None None CAT. LISTING GKCA1L6 GKCA1L7 GKCA1LX GKCA6LX GKCA10L6 GKCA14L6 GKCA14L7 GKCA14L9 GKCA30LX GKCA36LX GKCC1LX GKCC6LX GKCC30LX GKCC36LX Double LED indicator CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM KEY 90° CAT. LISTING GKDA14L7 www.honeywell.com/sensing CAT. LISTING GKCA14M6 22 / 0.87 Single LED indicator CONTACT 1NC/1NO 1NC/1NO 1NC/1NO 2NC 4NC 2NC/2NO, BBM 2NC/2NO, BBM 2NC/2NO, BBM 4NC, low energy 3NC/1NO, BBM, low energy 1NC/1NO 2NC 4NC, low energy 3NC/1NO, BBM, low energy KEY straight Opening to left and top * fluorocarbon seal CONDUIT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 20 mm 20 mm 20 mm 20 mm 88 CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM KEY Straight 90° CAT. LISTING GKCA14P6 GKCA1P7 Double LED indicator CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM KEY 90° CAT. LISTING GKDA14P7 SAFETY SWITCHES GKL/GKR Series Dual Entry Solenoid Key Operated Safety Interlock Switch The GKR (head to the right) and GKL (head to the left) products offer the user an unrivalled range of standard options. The GKR/GKL product is a key actuated device incorporating a key trapping mechanism. The switch is used on machinery where instant stop and access to the machinery is either impossible (due to the momentum of the machine) or impractical (due to tool or machine damage or scrapped product if the current machine cycle is interrupted). The switch incorporates an optional manual override feature which allows removal of the key for emergency access. Over 1000 options are available in a simple to understand part number tree. A safety lockout device is also available for use with the GKR/GKL Series. The lockout device (GKZL2) is specifically designed to prevent a key from being inserted either manually, or by the access door being closed while maintenance personnel are working on the machine. When inserted, the lockout device can accommodate up to four padlocks to prevent unauthorised removal of the device. Mechanical life: Sealing: Operating temperature: Approvals: Contacts: up to 1 million IP 68, NEMA/UL type 1, 4, 6P, 12,13 -25 °C to 40 °C [-13 °F to 104 °F] CE, CSA, UL AC15 A300/A600 DC13 Q300 Silver Low energy Gold-plated Switching options: Snap Action Type 11NC/1NO Direct Opening 13 14 21 22 Zb Slow Acting Type 3 1NC/1NO, Break before make (BBM) 21 22 13 14 Type 14/15 2NC/2NO, Break before make (BBM) 11 12 21 22 33 34 43 44 2Y, 2X Zb 2 Slow Acting Type 36 3NC/1NO, Break before make (BBM),low energy Type 40 4NC 11 12 11 12 21 22 21 22 31 32 31 32 4Y 41 42 3Y, 1X 43 44 Type 44 2NC/2NO, Break before make (BBM) 11 12 21 22 33 34 43 44 2Y,2X Type 46 3NC/1NO, Break before make (BBM) 11 12 21 22 31 32 43 44 3Y,1X www.honeywell.com/sensing 89 SAFETY SWITCHES GKL/GKR Series (continued) Key: Type 6 Type 9 Type X Straight Side - side, spring loaded No key Latching mechanism: Type A Mechanical (solenoid unlock with screwdriver) Mechanical (without override) Electrical (solenoid unlock with screwdriver) Type B Type S OPTIONS Opening to front and top 9/ 0.35 Solenoid voltage: Type 2 Type 4 24 Vdc 120 Vac Electrical ratings: Designation & Utilization Category AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 Left 1/2 in - NPT buna-n seals CONTACT TYPE 3 (1NC/1NO, BBM) 40 (4NC) 46 (3NC, BBM) KEY None None None LATCHING TYPE A A A SOLENOID VOLTAGE 24 Vdc 24 Vdc 24 Vdc CAT. LISTING SOLENOID VOLTAGE 24 Vdc 24 Vdc CAT. LISTING GKLE3LXA2 GKLE40LXA2 GKLE46LXA2 Right 1/2 in - NPT buna-n seals 32,5 / 1.28 19 / 0.75 33 / 1.30 CONTACT TYPE 40 (4NC) 46 (3NC, BBM) 31 / 1.22 43,7 / 2 x 7,3 / 1.72 0.29 2 x ø 5,3 / 0.21 75 / 2.95 2 x 5,3 / 0.21 100 / 3.94 105,3 / 4.13 110 / 4.33 20 / 0.79 90 43 / 1.69 48,8 / 1.92 65 / 2.56 100 / 3.94 110 / 4.33 www.honeywell.com/sensing KEY None None LATCHING TYPE A A GKRE40LXA2 GKRE46LXA2 SAFETY SWITCHES Opening to left and top Opening to right and top 26 / 1.02 12 / 0.47 Left 1/2 in - NPT buna-n seals Right 1/2 in - NPT buna-n seals CONTACT TYPE 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) KEY None None None None None None None LATCHING TYPE A A S S A A S SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc CAT. LISTING LATCHING TYPE A A S S A A A S S SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 24 Vdc 120 Vac 24 Vdc 120 Vac CAT. LISTING GKRE3MXA2 GKRE3MXA4 GKRE3MXS2 GKRE3MXS4 GKRE36MXA2 GKRE36MXA4 GKRE36MXS2 20 mm - buna-n seals CONTACT TYPE 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) KEY None None None None None None None None None CONTACT TYPE 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) KEY None None None None None None None None LATCHING TYPE A A S S A A S S SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 120 Vac CAT. LISTING LATCHING TYPE A A S S S A A S S B SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc CAT. LISTING GKLE3PXA2 GKLE3PXA4 GKLE3PXS2 GKLE3PXS4 GKLE36PXA2 GKLE36PXA4 GKLE36PXS2 GKLE36PXS4 20 mm - buna-n seals GKRG1MXA2 GKRG1MXA4 GKRG1MXS2 GKRG1MXS4 GKRG3MXA2 GKRG36MXA2 GKRG36MXA4 GKRG36MXS2 GKRG36MXS4 CONTACT TYPE 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 44 (2NC/2NO, BBM) www.honeywell.com/sensing KEY Non None None None None None None None None None GKLG1PXA2 GKLG1PXA4 GKLG1PXS2 GKLG1PXS4 GKLG3PXS2 GKLG36PXA2 GKLG36PXA4 GKLG36PXS2 GKLG36PXS4 GKLG44PXB2 91 SAFETY SWITCHES Keys for GK and GKL/GKR switches Straight key 49,8 / 1.96 8,5 / 0.33 Locking slider bolt with actuating key 77 / 3.03 20 / 0.79 2x ø 5,3 / 0.21 14 / 0.55 15 / 0.59 3x HOLE PROVIDED FOR LOCKOUT 19,0 / .75 3/ 0.12 CAT. LISTING GKZ56 90° key 8,5 / 0.33 14 / 0.55 49,8 / 1.96 2 x ø 5,3 / 0.21 40 / 1.57 52 / 2.05 7,0 ±,7 / .28 ±.03 CAT. LISTING GKZ57 Spring-loaded key: up/down 4x ø 5,1 / .20 4,93 / .194 26,97 / 36,8 / 1.062 1.45 14,0 / .55 41,81 ±,76 / 1.646 ±.030 115,87 / 4.562 140,0 ±,7 / 5.51 ±.03 12,04 / .474 13,5 / 0.53 18,5 / 0.73 17,8 / 0.70 37,10 ±1,52 / 1.460 ±.060 26,77 ±1,52 / 1.054 ±.060 8,5 / 0.33 0°key rotation CAT. LISTING GKZ71 180° key rotation CAT. LISTING GKZ73 90° key rotation CAT. LISTING GKZ72 270° key rotation CAT. LISTING GKZ74 2 X ø 5,3 / 0.21 84,9 / 3.34 40 / 30 / 1.57 1.18 14 / 0.55 CAT. LISTING GKZ58 Spring-loaded key: left/right 8,5 / 0.33 84,9 / 3.34 2 X ø 5,3 / 14 / 0.55 0.21 20,5 / 0.81 18,5 / 0.73 13,5 / 0.53 30 / 1.18 40 / 1.57 CAT. LISTING GKZ59 92 www.honeywell.com/sensing SAFETY SWITCHES GKE Series Dual Entry Safety Interlock Switch The GKE Series safety key-operated switch provides enhanced reliability for safety hard-guarding applications in a compact, cost-effective package. Mechanical life: Sealing: Operating temperature: Approvals: 1 million IP 66, NEMA 1, 12,13 -25 °C to 85 °C [-13 °F to 185 °F] cULus, CE AC15 A500/A600 DC13 Q300 Switching options: Switch Code 01: 1NC/1NO 13 14 Zb 21 22 Switch Code 03: 1NC/1NO (BBM) 21 22 Zb 13 14 Switch Code 06: 2NC 21 22 2Y 11 12 Designation & Utilization Category AC15 AC15 DC13 A500 A600 Q300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 24V 120 V 240 V 380 V 480 V 500 V – 6 3 1,9 1,5 1,4 – 6 3 1,9 1,5 1,4 2,8 0,55 0,27 – – – www.honeywell.com/sensing 600 V – 1,2 – 93 SAFETY SWITCHES OPTIONS Head Code L Dual Entry, Key Operated Head Code M 1/2 in NPT conduit CONTACT TYPE 1NC/1NO 1NC/1NO BBM 2NC SWITCH CODE 01 01 03 CAT. LISTING GKEA1LX GKEC1LX GKEA3LX Head Code N M20 x 1,5 conduit CONTACT TYPE 1NC/1NO 1NC/1NO BBM 2NC SWITCH CODE 03 06 06 CAT. LISTING GKEC3LX GKEA6LX GKEC6LX Head Code P 94 www.honeywell.com/sensing SAFETY SWITCHES GKZ51M Key and Mounting GKZ52M Key and Mounting 90 degree key Straight key CAT. LISTING GKZ52M CAT. LISTING GKZ51M www.honeywell.com/sensing 95 SAFETY SWITCHES GKN Safety Key Operated Switch The GKN Series safety interlock switches provide enhanced reliability in a compact, cost-effective package size. A black plastic snap fit cover is provided to plug the unused key entry window. Straight and 90 degree actuator keys are available seperately. The GKN Series conforms to IEC 60947-5-1 and carries cULus and CE approvals. Mechanical life: Sealing: Operating temperature: Approvals: 1 million IP 67, NEMA 1, 12,13, 4 (indoor use only) -25 °C to 85 °C [-13 °F to 185 °F] cULus, CE Switching options: 2NC/1NO MBB 1NC/1NO MBB 1NC/1NO BBM 1NC/2NO MBB 2NC Designation & Utilization Category AC15 DC13 96 A600 Q300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 125V 240 V 6 – 3 – 0,55 0,27 www.honeywell.com/sensing 600 V 1,2 – SAFETY SWITCHES OPTIONS GKZB1 Dual Entry, Key Operated Straight stainless steel key CAT. LISTING GKZB1 GKZB2 Straight thermoplastic key M20 x 1,5 conduit CONTACT TYPE 1NC/1NO BBM 1NC/1NO MBB 2NC/1NO MBB 1NC/2NO MBB 2NC CAT. LISTING GKZB2 GKZB6 CONDUIT OPENINGS 3 3 2 2 3 CAT. LISTING GKNC3L GKNC4L GKNC12l GKNC33L GKNC6L Flexible key www.honeywell.com/sensing CAT. LISTING GKZB6 97 98 www.honeywell.com/sensing SAFETY SWITCHES CPS Series Cable Pull Safety Switch CPS Series Cable Pull Safety Switches provide a readily accessible emergency stop signal. This is a cost-effective means compared to using multiple emergency stop push-buttons. (Cable Pull Safety Switches are not, however, to be used as a means of personnel safeguarding. They may be used to prevent further injury or damage to equipment when used for emergency stop signaling.) The CPS Series Cable Pull Safety switch is designed to provide emergency stop protection for exposed conveyor and assembly lines. The internal mechanism latches on both slackened cable (push) and pulled cable. This capability also enhances productivity by eliminating nuisance stops due to variations in temperature, stretch of cable over time, and other application variables. The 1CPS is intended for use in applications where the cable span is 76 m [250 ft] or shorter. It is a potential economical solution for shorter runs or zone protection typical to automated systems. The 2CPS series is intended for use in very long cable runs of 152 m [500 ft] or shorter, such as long conveyor lines found in warehouses. The CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function; IEC/EN 60947-1; IEC/EN 60947-5-1; IEC/EN 60947-5-5. Mechanical life: 1 000 000 Sealing: IP67, NEMA 1, 4, 12,13 Operating temperature: 1CPS -40 °C to 80 °C [-40 °F to 176 °F] 2CPS -40 °C to 80 °C [-40 °F to 176 °F] Approvals: AC15 A300 DC13 Q300 1CPS UL, CSA 2CPS UL, CSA Contacts: 1CPS Silver 1CPS, Low energy Gold plated 2CPS Gold plate over silver Switching options: 1CPS 2CPS 1NC/1NO 21 22 13 14 N/A 2NC/2NO 21 22 21 22 21 22 21 22 13 14 13 14 13 14 13 14 21 22 11 12 21 22 11 12 13 14 21 22 13 14 21 22 11 12 11 12 11 12 11 12 21 22 21 22 21 22 21 22 3NC/1NO 4NC 2CPS contact block mounting: 1 2 1 To housing Removable with heavy duty terminals 2 I I 1CPS indicator Light Code: 2CPS indicator Light Code: No letter A B No letter A B www.honeywell.com/sensing No indicator provided 24 Vdc red LED 120 Vac red LED No indicator provided 24 Vdc red multi-cluster LED 120 Vac red multi-cluster LED 99 SAFETY SWITCHES CPS Series (continued) 1CPS 6,35 [0.25] B 152,4 [6.0] 81,28 [3.2] SLACK 1CPS Cable Pull Switch 88,9 [3.5] TENSIONED 33,02 [1.3] RUN RESET OFF 99,06 [3.9] 172,72 [6.8] 76,2 [3.0] 4X Ø 7,11 Ø 0.28 50,8 [2.1] 12,7 [0.5] 117,42 [4.623] A 65,20 [2.567] 56,79 [2.236] 50,83 [2.001] 3X 25,4 [1.0] 2X 26,67 [1.050] A B C D 25,4 [1.00] C 25,4 [1.00] D Fully extended Optional indicator Conduit thread (3 total) Mounting pad (4 total) OPTIONS Cable maintained 1/2 in NPT CONTACT 1NC/1NO 1NC/1NO 1NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 4NC 1NC/1NO, low energy 2NC/2NO, low energy 2NC/2NO, low energy 2NC/2NO, low energy 3NC/1NO, low energy 4NC, low energy 100 20 mm INDICATOR None 24 V 120 V None 24 V 120 V None 24 V 120 V None None None 24 V 120 V None None CAT. LISTING 1CPSA1 1CPSA1A 1CPSA1B 1CPSA2 1CPSA2A 1CPSA2B 1CPSA3 1CPSA3A 1CPSA3B 1CPSA4 1CPSA5 1CPSA6 1CPSA6A 1CPSA6B 1CPSA7 1CPSA8 CONTACT 1NC/1NO 1NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 4NC 1NC/1NO, low energy 2NC/2NO, low energy 2NC/2NO, low energy 3NC/1NO, low energy 4NC, low energy www.honeywell.com/sensing INDICATOR None 24 V None 24 V 120 V None 24 V None None None 24 V None None CAT. LISTING 1CPSC1 1CPSC1A 1CPSC2 1CPSC2A 1CPSC2B 1CPSC3 1CPSC3A 1CPSC4 1CPSC5 1CPSC6 1CPSC6A 1CPSC7 1CPSC8 SAFETY SWITCHES 2CPS 40,4 (1.60) 67,8 (2.63) 79,8 (3.14) 92,9 (3.66) 325,9 A (12.75) 152,4 (6.00) 52,1 (2.05) 12,7 (0.50) 18,3 (0.72) SLACK RUN OFF TENSIONED 34,9 (1.38) SLACK TENSIONED 21,1 (0.75) 152,4 (6.00) 2X D 2X 2X 8,9 (0.35) 81,3 (3.20) 40,5 (1.60) 6,9 (0.27) 104,8 (4.13) 2X C B 6,4 (0.25) 2X 31,75 (1.25) 57,2 (2.25) 12,7 (0.50) 2X D C 2X 6,9 (0.27) 3X 21,5 (0.85) 139,7 (5.50) OFF Cable maintained both sides 1/2 in NPT CONTACT 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO CONTACT BLOCK MOUNTING 1 1 1 1 1 1 2 2 2 2 2 2 INDICATOR CAT. LISTING CONTACT None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac 2CPSA1A1 2CPSA1A1A 2CPSA1A1B 2CPSA1B1 2CPSA1B1A 2CPSA1B1B 2CPSA2A1 2CPSA2A1A 2CPSA2A1B 2CPSA2B1 2CPSA2B1A 2CPSA2B1B 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 2NC/2NO 2NC/2NO 4NC Fully extended Optional indicator C Conduit thread (3 total) D Mounting pad (4 total) INDICATOR CAT. LISTING None 24 Vdc 24 Vdc 2CPSC1A1 2CPSC1A1A 2CPSC1D1A CONTACT BLOCK MOUNTING 1 1 1 1 1 1 2 2 2 INDICATOR CAT. LISTING None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac 2CPSA1A2 2CPSA1A2A 2CPSA1A2B 2CPSA1B2 2CPSA1B2A 2CPSA1B2B 2CPSA2A2 2CPSA2A2A 2CPSA2A2B INDICATOR CAT. LISTING None 24 Vdc 2CPSC1A2 2CPSC1A2A 20 mm CONTACT CONTACT BLOCK MOUNTING 1 1 1 A B No actuation right side, cable maintained left side 1/2 in NPT 20 mm CONTACT SLACK RUN TENSIONED SLACK TENSIONED 244,6 A (9.63) 2NC/2NO 2NC/2NO CONTACT BLOCK MOUNTING 1 1 No actuation left side, cable maintained right side 1/2 in NPT CONTACT 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO CONTACT BLOCK MOUNTING 1 1 1 1 1 1 2 2 2 INDICATOR CAT. LISTING None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac 2CPSA1A3 2CPSA1A3A 2CPSA1A3B 2CPSA1B3 2CPSA1B3A 2CPSA1B3B 2CPSA2A3 2CPSA2A3A 2CPSA2A3B INDICATOR CAT. LISTING None 24 Vdc 2CPSC1A3 2CPSC1A3A 20 mm CONTACT 2NC/2NO 2NC/2NO CONTACT BLOCK MOUNTING 1 1 www.honeywell.com/sensing 101 SAFETY SWITCHES CPS Series (continued) Hardware packets (order separately) CPS LED 31,75 [1.25] 71,88 ±2,54 [2.83 ±0.10] 11,43 [0.45] C B D A 207,01 ±1,27 [8.15 ±0.05] 227,33 ±12,7 [8.95 ±0.50] CPS Bracket ACCESSORY Cable - 7,6 m [25 ft] length Cable - 15,2 m [50 ft] length Cable - 30,5 m [100 ft] length Cable - 45,7 m [150 ft] length Cable - 61 m [200 ft] length Cable - 76,2 m [250 ft] length (2) Thimbles (2) Low-profile Duplex Cable Clamps 102 CAT. LISTING CLSZC1 CLSZC2 CLSZC3 CLSZC4 CLSZC5 CLSZC7 CLSZTC ACCESSORY (1) Draw-bar Endspring (1) J-hook Turnbuckle with Lock Nuts (2) Thimbles (2) Low-profile Duplex Cable Clamps (16) Sets of Cable Supports ((16) 1/4-20 Eye Bolts, (32) 1/4-20 Nuts, (32) Flat Washers, (16) Lock Washers) Multicluster LED Accessory - 24 Vdc (conduit mount) Multicluster LED Accessory - 120 Vdc (conduit mount) Mounting bracket (to be used with 1CPS or 2CPS) J-hook turnbuckle with lock nuts (included with 2CPS) www.honeywell.com/sensing CAT. LISTING CPSZ1S CPSZK1 CPSLED24 CPSLED120 CPS-BRACKET CPSZTB BASIC SWITCHES Basic Switches These listings include standard size basics, miniature and subminiature switches. The precision snap-action mechanisms are offered with a wide variety of actuators and operating characteristics. Basic switches are often ideal for applications requiring compactness, light weight, accurate repeatability and long life. They are best used for presence/absence detection where physical contact with object is permissible. Very economical. OPTIONS Note: BA/BE plunger position distance from mounting hole = 19 mm [0.75 in] BZ/BA/BM/BE Series Basic Switches BZ/BA/BM/BE Series standard basic switches may be used for simple or precision on/off application needs. As well as the catalogue listings presented here, we offer other versions with higher temperature ratings, different termination options, different electrical ratings and Single Pole, Single Throw (SPST) circuitry. Refer to our Web site for details. Voltage: Electrical rating: Operating temperature: Termination: Contact type: Approvals: Switching options: 250 Vac up to 25 A -55 °C to 85 °C [-67 ° F to 185 °F] Screw Silver CE, CSA, UL, ENEC Single pole, double throw (SPDT) Top pin plunger Approvals: BE-2R-A4 ELECTRICAL RATING 15 A 15 A 15 A 15 A 25 A TERMINATION Solder Screw Solder Screw Screw CSA, UL CAT. LISTING BZ-R BZ-R-A2 BZ-R169 BZ-2R-A2 BE-2R-A4 Overtravel plunger (standard) ELECTRICAL RATING 15 A 20 A TERMINATION Screw Screw CAT. LISTING BZ-2RD-A2 BA-2RB-A2 Panel mount overtravel plunger ELECTRICAL RATING 15 A 20 A www.honeywell.com/sensing TERMINATION Screw Screw CAT. LISTING BZ-2RQ1-A2 BA-2RQ1-A2 103 BASIC SWITCHES BASIC SWITCHES BZ/BA/BM/BE Series (continued) Overtravel plunger (splash resistant) ELECTRICAL RATING 15 A 15 A (Stainless steel spring) Straight lever TERMINATION Screw Screw CAT. LISTING BZ-2RDS-A2 BZ-2RDS-A2S Overtravel roller plunger ELECTRICAL RATING 15 A ELECTRICAL RATING 20 A 15 A 15 A TERMINATION Screw Screw Screw TERMINATION Screw 104 APPROVALS Screw CAT. LISTING BA-2RV-A2 BZ-2RW80-A2 BZ-2RW863-A2 Roller lever CAT. LISTING BZ-2RQ18-A2 ELECTRICAL RATING 15 A 15 A 15 A (Splash resistant) 15 A 15 A TERMINATION Screw Solder Screw Screw Screw Overtravel roller plunger, perpendicular ELECTRICAL RATING 15 A LEVER RADIUS 63,5 mm [2.5 in] 63,5 mm [2.5 in] 152,4 mm [6.0 in] CAT. LISTING BZ-2RQ181-A2 www.honeywell.com/sensing LEVER RADIUS 26,67 mm [1.05 in] 26,67 mm [1.05 in] 26,67 mm [1.05 in] One way, 32,0 mm [1.26 in] 48,3 mm [1.9 in] CAT. LISTING BZ-2RW822-A2 BZ-2RW822 BZ-2RW8225551-A2 BZ-2RW826-A2 BZ-2RW82-A2 BASIC SWITCHES DT Series Basic Switches DT Series standard basic switches consist of two independent single-pole double throw circuits in one housing actuated by one actuator. The terminals are separated by a non-conductive shield to reduce shorting. Voltage: Electrical rating: Operating temperature: Termination: Contact type: Approvals: Switching options: 250 Vac 10 A -55 °C to 85 °C [-67 ° F to 185 °F] Screw Silver CSA, UL Double pole, double throw (DPDT) TB Series Miniature Double-break Basic Switches TB Series miniature double-break basic switches are basic double-break units that offer a means of controlling isolated circuits. Each circuit may be driven by an independent voltage source. Voltage: 250 Vac Electrical rating: 10 A Operating temperature: -55 °C to 125 °C [-67 ° F to 257 °F] Termination: Solder Contact type: Silver Approvals: CSA, UL Switching options: Single pole, double throw, double break (SPDT DB) Dimensions in inches 1.825 REF 1.57 0.53 0.50 0.87 DIA HOLE IN TERMINALS (4) 0.13 0.20 0.24 0.15 PLASTIC PLUNGER 0.260 0.22 0.16 R 0.113 ± .002 DIA 0.06 MAX PRETRAVEL +.002 0.101 - .001 Top pin plunger ELECTRICAL RATING 10 A 0.46 OPERATING POSITION 0.312 ± .003 TERMINATION Screw CAT. LISTING DT-2R-A7 4 3 1 2 0.50 0.25 0.03 +.002 0.101 - .001 DIA HOLE 0.365 0.09 0.532 ± .003 1.25 NOTE1 - TERMINALS 1 & 2 NORMALLY CLOSED CIRCUIT 2 - TERMINALS 3 & 4 NORMALLY OPEN CIRCUIT 3 - TERMINALS ARE PLATED FOR SOLDERING Basic Switch Accessories A range of accessories is available for BZ, BA, BM, BE and DT switches, such as the 5PA2 terminal enclosure. For more information please contact your local sales office. Top pin plunger ELECTRICAL RATING 10 A www.honeywell.com/sensing TERMINATION Solder CAT. LISTING 1TB1-2 105 BASIC SWITCHES SM and SX Series Subminiature Basic Switches SM and SX Series subminiature basic switches may be used for simple or precision on/off application needs. These switches combine small size and light weight with ample electrical capacity, precision operation and long life. The SX Series are small, precision, snap-action switches that are often ideal where savings in space and weight are important. Voltage: Operating temperature: Termination: Contact type: Switching options: 250 Vac -55 °C to 125 °C [-67 ° F to 257 °F] Solder Silver Single pole, double throw (SPDT) Roller lever TERMINATION ELECTRICAL RATING Solder/quick connect 5 A CONTACT TYPE silver CAT. LISTING 111SM2-T SX Series Approvals: Electrical rating: CE, CSA, UL 5A OPTIONS SM Series Approvals: Electrical rating: CE, CSA, UL 5A OPTIONS Top pin plunger Approvals: 6SX7-T CONTACTS Silver Silver Gold UL, CSA ELECTRICAL RATING 7A 3A 1A CAT. LISTING 1SX1-T 11SX1-T 6SX7-T Top pin plunger Approvals: 11SM601-H4 TERMINATION ELECTRICAL RATING 5A Solder/quick connect 5 A UL, CSA CONTACT TYPE silver silver CAT. LISTING 11SM1 11SM601-H4 Straight lever CONTACT TYPE Silver Silver ELECTRICAL RATING 5A 5A LEVER LENGTH ‘A’ 12,8 mm ‘A’ 24,5 mm CAT. LISTING 311SX2-T 311SX3-T LEVER Roller CAT. LISTING 311SX5-T Straight lever LEVER LENGTH 4,83 mm ELECTRICAL RATING 5A CONTACT TYPE silver CAT. LISTING 111SM1 Simulated roller CONTACT TYPE Silver 106 ELECTRICAL RATING 5A www.honeywell.com/sensing BASIC SWITCHES UL/CSA 0.1 A or 3 A OPTIONS 0.1 A, 3 A, 5 A or 10.1 A 125/250 Vac 25 °C to 85 °C [-13 °F to 185 °F] Quick connect, solder, PCB Gold or silver SPDT 12.7 0.5 5.2 0.205 1.12 0.044 5.7 0.224 2.9 0.114 OPTIONS 0.9 0.035 6.5 0.256 5.08 0.2 3.15 0.124 5.08 1.24 0.2 0.049 5.8 0.228 12.8 0.504 1.6 0.063 0.043 3.6 0.138 é0.081 1.1 1.1 é2.05 é2.2 é0.087 0.043 UL/CSA 0.1 A, 5 A or 10.1 A 2.05 0.081 Approvals: Electrical rating: 1.5 0.059 OP ZM Series 6.5 0.256 Electrical rating: Voltage: Operating temperature: Termination: Contact type: Switching options: Approvals: Electrical rating: PT ZM, ZX, ZV and ZW Series subminiature basic switches are cost-effective devices used for simple on/off applications. These switches combine small size and light weight with ample electrical capability and long life. Plastic lever capability is available on the ZV Series. ZX Series FP ZM, ZX, ZV and ZW Series Subminiature Basic Switches 0.4 0.016 Top pin plunger TERMINATION PCB Solder ELECTRICAL RATING 3A 0.1 A CONTACT TYPE silver gold CAT. LISTING ZX40E30A01 ZX10C10A01 PT 6.5 0.256 FP é2.05 é0.081 é2.2 é0.087 0.9 0.035 6.5 0.256 5.08 0.2 12.8 0.504 3.15 0.124 5.08 1.24 0.2 0.049 5.8 0.228 1.6 0.063 CAT. LISTING ZM50E70A01 ZM50E10A01 ZM90G20A01 ZM10B10A01 0.043 0.043 CONTACT TYPE silver silver silver gold 1.1 1.1 ELECTRICAL RATING 5A 5A 10.1 A 0.1 A 5.2 0.205 2.9 0.114 3.6 0.138 Top pin plunger TERMINATION Quick connect Solder PCB Solder 1.12 0.044 5.7 0.224 1.5 0.059 2.05 0.081 3.4 0.134 13.0 0.512 OP 12.7 0.5 0.4 0.016 Straight lever TERMINATION PCB Solder ELECTRICAL RATING 3A 3A www.honeywell.com/sensing CONTACT TYPE silver silver CAT. LISTING ZX40E30C01 ZX40E10C01 107 BASIC SWITCHES PT BASIC SWITCHES 11.8 0.465 5.7 0.224 12.7 0.5 0.9 0.035 6.5 0.256 5.08 0.2 3.15 0.124 1.24 0.049 5.8 0.228 5.08 0.2 12.8 0.504 Straight lever TERMINATION Quick connect Solder ELECTRICAL RATING 5A 5A 0.043 1.6 0.063 0.043 3.6 0.138 é2.05 é0.081 é2.2 é0.087 1.1 1.1 2.05 0.081 6.5 0.256 5.2 0.205 FP OP 1.12 0.044 3.4 0.134 1.5 0.059 2.9 0.114 0.4 0.016 Simulated roller lever CONTACT TYPE silver silver CAT. LISTING ZM50E70D01 ZM50E10D01 TERMINATION PCB Solder ELECTRICAL RATING 3A 3A CONTACT TYPE silver silver CAT. LISTING ZX40E30E01 ZX40E10E01 ZV Series Approvals: Electrical rating: UL/ENEC 0.1 A, 5 A or 10.1 A OPTIONS Top pin plunger Simulated roller lever TERMINATION Quick connect Solder 108 ELECTRICAL RATING 5A 5A CONTACT TYPE silver silver CAT. LISTING ZM50E70E01 ZM50E10E01 TERMINATION PCB Solder Quick connect ELECTRICAL RATING 5A 5A 0.1 A www.honeywell.com/sensing CONTACT TYPE silver silver gold CAT. LISTING ZV50E20A01 ZV50E10A01 ZV10B70A01 BASIC SWITCHES BASIC SWITCHES ZW Sealed Series Approvals: Electrical rating: Sealing: UL/ENEC 0.1 A or 5 A IP50 and IP67 OPTIONS Straight lever TERMINATION Solder Quick connect ELECTRICAL RATING 5A 5A Top pin plunger CONTACT TYPE silver silver CAT. LISTING ZV50E10B01 ZV50E70C01 ELECTRICAL RATING 5A CONTACT TYPE silver CAT. LISTING ZW50F15AD1 ELECTRICAL RATING 0.1 A CONTACT TYPE gold CAT. LISTING ZW10E15CD1 ELECTRICAL RATING 0.1 A CONTACT TYPE gold CAT. LISTING ZW10E90FW1 Straight lever Roller lever TERMINATION PCB Quick connect TERMINATION Solder ELECTRICAL RATING 5A 5A CONTACT TYPE silver silver CAT. LISTING ZV50E20F01 ZV50E70F01 TERMINATION Solder Roller lever TERMINATION Wire leads www.honeywell.com/sensing 109 BASIC SWITCHES BASIC SWITCHES V7 Series Miniature Basic Switches Printed circuit board (PO2) V7 Series basic switches may be used for simple or precision on/off, end of limit, presence/absence, pressure, temperature and manual operator interface application needs. Operating temperature: -40 °C to 82 °C [-40 °F to 180 °F] (standard) -40 °C to 200 °C [-40 °F to 350 °F] (high temperature) Termination: V7-*A V7-*B V7-*C/W V7-*D V7-*E V7-*S V7-*V V7-*Z Printed circuit board (PCB) and two types of quick connect (QC) D8, E8: 4,8 mm x 0.5 mm [0.187 in x 0.02 in] E9: 6,35 mm x 0,80 mm [0.25 in x 0.032 in] Electrical rating 5A 11 A 15 A 1A 10 A 100 mA 21 A 25 A Contact Type Silver Silver Silver Gold alloy Silver Gold alloy Silver alloy Silver cadmium oxide Approvals: V7-*C/W (Electrical ratings) Switching options: CSA, UL, ENEC CSA, UL These terminals interface with snap-on receptacles and other components from AMPMODU interconnection system. PCB terminals are European approved when used with electrical ratings A, B, D, E, S. ACTUATION OPTIONS Single pole double throw (NO and NC) (SPDT) 10,2 .40 AVAILABLE TERMINALS 6,4 .25 20,2 .80 2,8 .11 Quick Connect (QC) 2,8 .11 1,0 .04 2,90 Ø hole (3,10/.122 option) .114 10,3 .41 2,8 .11 1,5 0.06 8,9 .35 18,2 MAX .72 NC COM 2,90 .114 DIA 3,10 .122 OPT 0.187 in wide x 0.020 in thick. D8 terminals are European approved when used with electrical ratings A, B, D, E or S. International approval agencies require that switches with these terminals have insulated receptacles or connector. 0.187 in wide x 0.020 in thick. E8 terminals are European approved when used with electrical ratings A, B, D, E or S. 22,2 .88 28,8 1.14 2,4 .10 14,4 .57 0,8 (3) .03 Note: The optional mounting hole dimensions shown above are standard on V5/V7 International Series switches. Top pin plunger CURRENT 5A 5A 11 A 11 A 15 A 15 A 1A 0.1 A 21 A 25 A 0.250 in wide x 0.032 in thick. E9 terminals are European approved when used with electrical ratings A, B, D, E, S, V or Z. 110 3,20 DIA .126 3,46 .134 OPT NO www.honeywell.com/sensing TERMINATION QC (D8) PCB QC (D8) QC (E9) QC (D8) QC (E9) QC (D8) QC (D8) QC (E9) QC (E9) CAT. LISTING V7-1A17D8 V7-1A17P02 V7-1B17D8 V7-1B19E9 V7-1C17D8 V7-1C17E9 V7-1D10D8 V7-1S17D8 V7-1V19E9 V7-1Z19E9 BASIC SWITCHES V7 Series Miniature Basic Switches (continued) Straight lever Type -002 ELECTRICAL RATING 15 A 15 A 11 A Roller lever Type -201 TERMINATION QC (D8) QC (E9) QC (E9) CAT. LISTING V7-1C17D8-002 V7-1C17E9-002 V7-2B17E9-002 Straight lever Type -022 ELECTRICAL RATING 5A 11 A 15 A 0.1 A TERMINATION QC (D8) QC (E9) QC (D8) QC (D8) CAT. LISTING V7-1C17D8-201 V7-1C17E9-201 V7-1S17D8-201 V7-2B17D8-201 TERMINATION QC (E9) QC (D8) QC (E9) QC (D8) QC (E9) QC (D8) QC (D8) CAT. LISTING V7-1B10E9-207 V7-1C17D8-207 V7-1C17E9-207 V7-1S17D8-207 V7-1V1939-207 V7-2A17D8-207 V7-7D17D8-207 TERMINATION QC (D8) QC (D8) QC (D8) QC (E9) CAT. LISTING V7-1B17D8-263 V7-1C17D8-263 V7-1S17D8-263 V7-3S17E9-263 Type -207 TERMINATION QC (D8) QC (D8) QC (D8) QC (D8) CAT. LISTING V7-1A17D8-022 V7-1B19D8-022 V7-1C17D8-022 V7-1S17D8-022 ELECTRICAL RATING 11 A 15 A 15 A 0.1 A 21 A 5A 1A Simulated roller lever Type -263 Type -048 ELECTRICAL RATING 11 A 15 A 21 A 11 A 0.1 A 15 A (High temperature) ELECTRICAL RATING 15 A 15 A 0.1 A 11 A TERMINATION QC(D8) QC(D8) QC(E9) QC(E9) QC(D8) QC(E9) CAT. LISTING V7-1B17D8-048 V7-1C17D8-048 V7-1V19E9-048 V7-2B19E9-048 V7-3S17D8-048 V7-9W1AE9-048 ELECTRICAL RATING 11 A 15 A 0.1 A 0.1 A www.honeywell.com/sensing 111 BASIC SWITCHES 112 www.honeywell.com/sensing PRESSURE SWITCHES Pressure Switches Honeywell has over 60 years of experience in the pressure switch industry. A wide variety of pressure ranges, along with a wide choice of mounting, package, and port configurations allows customers to choose from standard off-the-shelf designs. All Honeywell pressure switches feature excellent repeatability, enhanced accuracy and reliability under varying environmental conditions. In addition, they feature highly consistent operating characteristics from one sensor to the next and interchangeability without recalibration. www.honeywell.com/sensing 113 PRESSURE SWITCHES Honeywell’s pressure and vacuum switches are designed for use in heavy duty equipment. They are suitable for potential applications that are constantly subjected to harsh environments, such as chemical splashes, salt water or pressure spikes. Pressure Switches The products listed are standard switches, but other circuitry and terminal options are available. Switches can be customised to customer requirements, contact your local Honeywell sales office for more information. Operating temperature: Termination: Connector: Contacts: Electrical rating: Resistive Inductive Circuitry: -40 °C to 122 °C [-40 °F to 250 °F] #8-32 screws 1/8-27 NPT male thread Silver alloy, gold plated 15 A, 6 Vdc 8 A, 12 Vdc 4 A, 24 Vdc 1 A, 120 Vac 0.5 A, 240 Vac SPST-NO (Normally open) SPST-NC (Normally closed) 5000 Series Extended Duty Switch Set point range 0.5 psi to 150 psi [0.035 bar to 10.35 bar] This pressure switch was designed to stand up to extended duty applications. It is factory set but is capable of being field adjusted. The Kapton diaphragm is compatible with a wide variety of media with the exception of water. An optional Teflon diaphragm is available when water is the operating media. Direct action blade contacts, 2 terminals 58,42 (2.30) Other options are available - SPDT, NO/NO or NC/NC circuitry and blade or integral Packard MetriPack terminals - contact Honeywell sales office for details. Operating pressure: Set point range 0.5 psi to 24 psi [0.0345 bar to 1.656 bar] 25 psi to 150 psi [1.725 bar to 10.350 bar] = = = = Proof pressure: Burst pressure: Set point range 150 psi [10.350 bar] 250 psi [17.237 bar] 500 psi (34.474 bar] 0.5 psi to 24 psi [0.0345 bar to 1.656 bar] 25 psi to 150 psi [1.725 bar to 10.350 bar] = = = = 750 psi [51.711 bar] 1250 psi [86.185 bar] 37,34 (1.47) SPST-NO CONTACT SETTING PSI [BAR] 0.5 to 1.0 [0.0345 to 0.069] 1.1 to 3.0 [0.0759 to 0.207] 3.1 to 7.0 [0.2139 to 0.483] 8.0 to 13.0 [0.552 to 0.897] 14.0 to 24.0 [0.996 to 1.656] 25.0 to 50.0 [1.725 to 3.450] 51.0 to 90.0 [3.519 to 6.210] 91.0 to 150.0 [6.279 to 10.350] FACTORY SET AT PSI [BAR] 1.0 [0.069] 2.0 [0.138] 4.0 [0.276] 10.0 [0.690] 15.0 [1.035] 35.0 [2.415] 60.0 [4.140] 100.0 [6.90] CAT. LISTING 78628 76051 76575 76576 76052 76053 76054 76055 FACTORY SET AT PSI [BAR] 1.0 [0.069] 2.0 [0.138] 4.0 [0.276] 10.0 [0.690] 15.0 [1.035] 35.0 [2.415] 60.0 [4.140] 100.0 [6.90] CAT. LISTING 78632 76061 76577 76578 76062 76063 76064 76065 SPST-NC NOTE Operating Media (Pressure Switch) The pressure switch is designed to operate with air, motor oils, transmission oils, jet fuels and other similar hydrocarbon media. 114 CONTACT SETTING PSI [BAR] 0.5 to 1.0 [0.0345 to 0.069] 1.1 to 3.0 [0.0759 to 0.207] 3.1 to 7.0 [0.2139 to 0.483] 8.0 to 13.0 [0.552 to 0.897] 14.0 to 24.0 [0.996 to 1.656] 25.0 to 50.0 [1.725 to 3.450] 51.0 to 90.0 [3.519 to 6.210] 91.0 to 150.0 [6.279 to 10.350] www.honeywell.com/sensing PRESSURE SWITCHES 5000 Series Extended Duty Vacuum Switch Set point range 1.1 in to 22.0 in Hg [27,94 mm Hg to 558,80 mm Hg] The 5000 Series Extended Duty Vacuum switch is designed for vacuum applications. The factory setting cannot be changed or adjusted in the field. It features a fluorosilicone rubber diaphragm that is compatible with a wide range of media. 5000 Series Extended Duty Piston Switch Set point range 70 psi to 1000 psi [13.80 bar to 68.95 bar] This switch is a variation of the “standard” 5000 Series Extended duty switch for applications requiring a compact package size, enhanced set point and operating characteristics. Other options are available - SPDT, NO/NO or NC/NC circuitry and blade terminals - contact Honeywell sales office for details. Blade terminal option is also available. Connector Operating vacuum: Burst pressure: 1/8-27 NPT Male 30 in Hg [762 mm Hg] 150 psi [10.35 bar] Direct action blade contacts Termination: Connector: Operating pressure: Proof pressure: Burst pressure: #8-32 screws or 280 Series MetriPack 1/2-20 UNF [O-ring fitted] 1000 psi [68.95 bar] 2000 psi [138.00 bar] 3000 psi [206.84 bar] OPTIONS 58,42 (2.30) Standard screw terminal, direct action blade contacts 62,23 (2.45) 37,34 (1.47) SPST-NO Internally grounded, 1 Terminal 2 Terminals CAT. LISTING 78813 77342 SPST-NC Internally grounded, 1 Terminal 2 Terminals CAT. LISTING 78815 77343 37,34 (1.47) SPST-NO CONTACT SETTING PSI [BAR] 70 to 400 [13.80 to 27.60] 401 to 800 [27.67 to 55.20] 801 to 1000 [55.27 to 69.00] APPROX. DIFFERENTIAL PSI [BAR] 30 to 100 [2.07 to 6.90] 40 to 125 [2.76 to 8.625] 50 to 180 [3.45 to 12.42] CAT. LISTING 79700 79704 79708 APPROX. DIFFERENTIAL PSI [BAR] 30 to 100 [2.07 to 6.90] 40 to 125 [2.76 to 8.625] 50 to 180 [3.45 to 12.42] CAT. LISTING 79702 79706 79710 SPST-NC CONTACT SETTING PSI [BAR] 70 to 400 [13.80 to 27.60] 401 to 800 [27.67 to 55.20] 801 to 1000 [55.27 to 69.00] Metri-Pack terminal, direct action blade contacts 77,47 (3.05) SPST-NO CONTACT SETTING PSI [BAR] 200 to 350 [13.80 to 24.15] 351 to 500 [24.22 to 34.50] 501 to 750 [34.57 to 51.75] 37,34 (1.47) APPROX. DIFFERENTIAL PSI [BAR] 30 to 100 [2.07 to 6.90] 40 to 125 [2.76 to 8.625] 50 to 150 [3.45 to 12.42] CAT. LISTING 79718 79720 79722 APPROX. DIFFERENTIAL PSI [BAR] 30 to 100 [2.07 to 6.90] 40 to 125 [2.76 to 8.625] 50 to 150 [3.45 to 12.42] CAT. LISTING 79719 79721 79723 SPST-NC CONTACT SETTING PSI [BAR] 200 to 350 [13.80 to 24.15] 351 to 500 [24.22 to 34.50] 501 to 750 [34.57 to 51.75] Mating connector - Packard Part Number 15300027 www.honeywell.com/sensing 115 PRESSURE SWITCHES 5000 Series Ultra Duty Switch Set point range 10 psi to 400 psi [0.69 bar to 27.60 bar] The 5000 Series Ultra Duty pressure switch is designed for high pressure/low set point applications that can experience sudden pressure spikes and high system pressures. Screw machined and heat treated components along with a reduced effective area in the pressure cavity allow improved performance over the standard extended duty 5000 Series. Other options are available - Dual Circuit (SPDT) configuration and blade or integral Packard MetriPack terminals - contact Honeywell sales office for details. Connector Operating pressure: Proof pressure: Burst pressure: 1/8-27 NPT Male 500 psi [34.50 bar] 2000 psi [138.00 bar] 4000 psi [276.00 bar] Pressure Switches Customised The pressure and vacuum switches on the following pages are custom built to customer specification, therefore minimum order quantities are required. Catalog listings are for reference only. Standard specification is shown below, but other contact, termination and connector options are available. Contact Honeywell for more information. Operating temperature: -40 °C to 122 °C [-40 °F to 250 °F] 8 in (203,2 mm) wire leads - 18 ga 1/8-27 PTF SAE short male thread Gold over silver Resistive 15 A, 6 Vdc 8 A, 12 Vdc 4 A, 24 Vdc Inductive 1 A, 120 Vac 0.5 A, 240 Vac SPST-NO (Normally open) SPST-NC (Normally closed) SPDT (Dual circuit) Termination: Connector: Contacts: Electrical rating: Circuitry: Direct action blade contacts, 2 terminals Series III Factory Set Variable Differential Pressure and Vacuum Switches 58,42 (2.30) The Series III features a snap action switch with gold contacts that provides hysteresis, low contact resistance, enhanced transfer time and an adjustable differential. 37,34 (1.47) Operating pressure: Proof pressure: Burst pressure: SPST-NO CONTACT SETTING PSI (BAR] 10 to 35 [0.69 to 2.41] 35 to 75 [2.41 to 5.17] 75 to 150 [5.17 to 10.35] 150 to 250 [10.35 to 17.25] 250 to 400 [17.25 to 27.6] FACTORY SET AT PSI [BAR] 20 [1.38] 60 [4.14] 100 [6.90] 200 [13.89] 300 [20.70] CAT. LISTING 83298 83301 83304 83307 83310 FACTORY SET AT PSI [BAR] 20 [1.38] 60 [4.14] 100 [6.90] 200 [13.89] 300 [20.70] CAT. LISTING 83299 83302 83305 83308 83311 200 psi [13.80 bar] 350 psi [24.13 bar] 500 psi [34.49 bar] 63,50 (2.5) SPST-NC CONTACT SETTING PSI [BAR] 10 to 35 [0.69 to 2.41] 35 to 75 [2.41 to 5.17] 75 to 150 [5.17 to 10.35] 150 to 250 [10.35 to 17.25] 250 to 400 [17.25 to 27.6] 42,93 (1.69) OPTIONS Pressure switch, snap action contacts Set point range - 2 psi to 70 psi [0.138 bar to 4.83 bar] SET POINT RANGE PSI [BAR] 2 to 4 [0.138 to 0.276] 4 to 12 [0.276 to 0.828] 12 to 24 [0.828 to 1.656] 24 to 40 [1.656 to 2.760] 40 to 70 [2.760 to 4.830] DIFFERENTIAL PSI [BAR] 1 to 1.5 [0.069 to 0.103] 2 to 6 [0.138 to 0.414] 8 to 12 [0.552 to 0.828] 10 to 18 [0.690 to 1.242] 15 to 20 [1.035 to 1.380] REF. LISTING 120000 120001 120002 120003 120004 Vacuum switch, snap action contacts Set point range 1.1 in Hg to 22 in Hg [27,94 mm Hg to 558,8 mm Hg] SET POINT RANGE IN HG [MM HG] 15 in H2O to 36 in H2O [28,025 to 67,259] 2 to 6 [50,8 to 152,4] 6 to 12 [152,4 to 304,8] 12 to 22 [304,8 to 558,8] 116 www.honeywell.com/sensing DIFFERENTIAL IN HG [MM HG] 4 in H2O to 12 in H2O [7,473 to 22,420] 0.4 to 1 [10,16 to 25,40] 0.4 to 1 [10,16 to 25,4] 0.6 to 1.5 [15,24 to 38,1] REF. LISTING 120005 120006 120007 120008 PRESSURE SWITCHES Pressure Switches - Customised (continued) Series V High Pressure, Environmentally Sealed, Extreme Duty Switches Set point range 35 psi to 3000 psi [2.415 bar to 206.84 bar] The Series V features a snap action switch with gold-plated contacts that provides hysteresis, low contact resistance, enhanced transfer time and an adjustable differential. OPTIONS Diaphragm switch, snap action contacts Set point range 35 psi to 300 psi [2.415 bar to 20.70 bar] Piston seal switch, snap action contacts Set point range 100 psi to 3000 psi [6.90 bar to 206.84 bar] The diaphragm material is fluorosilicone and is compatible with air, motor and transmission oil and other hydrocarbon media. The piston seal is nitrile and is compatible with motor and transmission oil and other hydrocarbon media. An optional seal is available for use with brake fluid. Connector: Operating pressure: Proof pressure: Burst pressure: 1/8-27 300 psi [20.70 500 psi [34.47 2000 psi [138.00 PTF bar] bar] bar] Connector: Operating pressure: Proof pressure: Burst pressure: 81,03 (3.19) 84,84 (3.34) 30.15 (1.187) SET POINT RANGE PSI [BAR] 35 to 50 [2.415 to 3.45] 50 to 100 [3.45 to 6.90] 100 to 200 [6.90 to 13.80] 200 to 300 [13.80 to 20.70] 3/4-16 UNF (O-ring fitting) 3000 psi [206.84 bar] 5000 psi [345.00 bar] 10000 psi [690.00 bar] DIFFERENTIAL PSI [BAR] 10 to 15 [0.690 to 1.035] 10 to 15 [0.690 to 1.035] 10 to 15 [0.690 to 1.035] 10 to 20 [0.690 to 1.380] 30.15 (1.187) REF. LISTING 26900 26901 26902 26903 SET POINT RANGE PSI [BAR] 100 to 150 [6.90 to 10.35] 150 to 250 [10.35 to 17.25] 250 to 500 [17.25 to 34.50] 500 to 750 [34.50 to 48.30] 750 to 1000 [48.30 to 69.00] 1000 to 1250 [69.00 to 86.25] 1250 to 1500 [86.25 to 103.50] 1500 to 1750 [103.50 to 120.75] 1750 to 2000 [120.75 to 138.00] 2000 to 2250 [138.00 to 155.25] 2250 to 2500 [155.25 to 172.50] 2500 to 2750 [172.50 to 189.75] 2750 to 3000 [189.75 to 206.84] www.honeywell.com/sensing DIFFERENTIAL PSI [BAR] 35 to 50 [2.415 to 3.450] 50 to 75 [3.450 to 5.175] 75 to 100 [5.175 to 6.90] 100 to 150 [6.90 to 10.35] 150 to 300 [10.35 to 20.70] 175 to 350 [12.075 to 24.15] 175 to 360 [12.075 to 24.84] 220 to 370 [15.18 to 25.53] 230 to 380 [15.87 to 26.22] 250 to 390 [17.25 to 26.91] 355 to 400 [24.495 to 27.60] 370 to 420 [25.53 to 28.98] 385 to 450 [26.565 to 31.05] REF. LISTING 26904 26905 26906 26907 26908 26909 26910 26911 26912 26913 26914 26915 26916 117 118 www.honeywell.com/sensing ENVIRONMENT SEALED SWITCHES Environment Sealed, Hermetically Sealed and Manual switches Most of the products in this section have one thing in common - they are sealed to withstand harsh environments. You will find them in such diverse places as landing gears, flaps, cargo doors and cockpit panels. Environmentally sealed products also satisfy needs in many other potential applications. Some examples are agriculture, transportation, construction, marine, ordnance and command and control equipment. Our commitment to quality products begins with the design of the products. Marketing, design and manufacturing engineering personnel review the customer specifications and translate them into design and manufacturing instructions. Every product Honeywell manufactures, be it an aerospace, industrial or commercial design, follows a single, uniform system of quality assurance. This helps ensure the same high level of reliability in all our products. Our aim is to build in quality. We have evaluation test labs that can subject our designs to most every test and environmental condition known to exist in our world or in outer space. Test equipment includes - electrical and mechanical life cycling devices, high-low temperature chambers, hydrostatic pressure chambers, impact shock machines, vibration equipment, centrifugal acceleration equipment, humidity and salt spray chambers, and dielectric strength testing equipment. Switch load/life Switch life depends on such criteria as electrical load, environment, switch mechanism and other factors peculiar to the application. As electrical load increases, switch life decreases. For military qualification testing 25,000 operations electrical life at rated load (maximum recommended load) is the minimum operations required. In most cases switch life exceeds 25,000 operations when operated at electrical loads less than rated load. Below one amp, the electrical life approaches the mechanical life of the switch. If your application requires more than 25,000 cycles and your electrical load is less than rated load, please contact Honeywell for application assistance. Sealed basic switches and switch assemblies Basic switches are either environment sealed or hermetically sealed. The environment sealed basics have a watertight seal and most meet military specifications. Limit switches are environment sealed or hermetically sealed and some are suitable for high temperature applications. Most switches meet appropriate military requirements. Environment sealed limit switches come in a choice of sizes and are offered for military aerospace and commercial aircraft applications. Hermetically sealed switches withstand temperatures up to 125 °C [257 °F], and high temperature hermetically sealed switches will operate in temperatures up to 334 °F [615 °F]. Manual control switches Standard size and some miniature toggle switches have bushing seals and are military qualified. Rocker switches also have a bushing seal. Rockers are easy to remove and are available in a variety of colours. Magnetically held toggle switches contain a holding coil to maintain the toggle in the operated position. They have environment sealing, and most are military qualified. To ensure you have the latest information on our product offering, contact Honeywell. www.honeywell.com/sensing 119 SEALED SWITCHES Basic switches operating characteristics Military specifications procurement information Electromechanical switches How to increase your effectiveness in using specification MIL-PRF8805 Definitions below explain the meaning of operating characteristics. Characteristics shown in tables throughout this catalog were chosen as most significant. They are taken at normal room temperature and humidity. These characteristics may vary as temperature and humidity conditions differ. Sketches show how characteristics are measured for in-line plunger actuation. Linear dimensions for in-line actuation are from top of plunger to a reference line, usually the center of the mounting holes. Differential Travel (D.T.)—Plunger or actuator travel from point where contacts “snap-over” to point where they “snapback.” Free Position (F.P.)—Position of switch plunger or actuator when no external force is applied (other than gravity). Full Overtravel Force—Force required to attain full overtravel of actuator. Operating Position (O.P.)—Position of switch plunger or actuator at which point contacts snap from normal to operated position. Note that in the case of flexible or adjustable actuators, the operating position is measured from the end of the lever or its maximum length. Location of operating position measurement shown on mounting dimension drawings. Operating Force (O.F.)—Amount of force applied to switch plunger or actuator to cause contact “snap-over.” Note in the case of adjustable actuators, the force is measured from the maximum length position of the lever. Overtravel (O.T.)—Plunger or actuator travel safely available beyond operating position. Pretravel (P.T.)—Distance or angle traveled in moving plunger or actuator from free position to operating position. Release Force (R.F.)—Amount of force still applied to switch plunger or actuator at moment contacts snap from operated position to unoperated position. Total Travel (T.T.)—Distance from actuator free position to overtravel limit position. The following information is intended to increase your effectiveness in using the Specification MIL-PRF-8805, minimize your costs and reduce delivery time for switches procured to the Specification. Standard items (shown on QPL 8805) HONEYWELL suggests the following statement be used when ordering items appearing on QPL 8805: “Honeywell” catalog listing No. listed on QPL 8805 as No. .” Should additional requirements be needed for application of the switch in its end use, they should be specifically stated as part of the ordering information. Non-standard items (not shown on QPL 8805) Honeywell suggests the following statement be used when ordering items which do not appear on QPL 8805: “Switch drawing No. shall meet the following performance requirements of MIL-PRF-8805.” In-line plunger actuation The above statement to be supplemented by the performance requirements which you consider applicable. Why the suggested statements will minimize cost and delivery of nonstandard items Military Specification MIL-PRF-8805 requires a complete qualification test of non-standard items (unless you specifically call out the performance requirements which you consider applicable to your switch application). Complete qualification is costly and will delay shipment of switches. By specifying all those requirements which you consider applicable you can minimize both your cost and delivery flow time. General statements, such as “switch must meet requirements of MIL-PRF-8805”, require complete MIL-PRF8805 qualification tests. Toggle switch locking configurations Toggle switches are available with the following locking configurations A B D E F G H Locked In Three Positions Locked In Center and Extreme Position (Keyway Side) Locked Out Of Center Position Locked In Center Position Locked In Extreme Position (Opposite Keyway) Locked In Extreme Position (Keyway Side) Locked Out Of Center And Extreme Position (Keyway Side) J K L M N P Locked Out Of Center And Extreme Position (Opposite Keyway) Locked In Center And Extreme Position (Opposite Keyway) Locked Out Of Extreme Position (Keyway Side) Locked Out Of And Into Extreme Position (Opposite Keyway) Locked Out Of Extreme Position (Opposite Keyway) Locked Out Of And Into Extreme Position (Keyway Side) 120 www.honeywell.com/sensing Honeywell believes that you, the user, know best the specific requirements of your application. These requirements may be more or less severe than those reflected by the test parameters of MIL-PRF-8805. In the interest of supplying switches which will meet your requirements with a minimum of expense and delay, we suggest use of the applicable statement provided for Standard (QPL) items and Non-Standard items (not on QPL). Honeywell solicits submittal of your proposal prints for review and comment. This review may result in savings of time and cost for you. SEALED SWITCHES SE and XE Series Environmentally Sealed Basic Switches SE and XE Series switches are the smallest, environment sealed switches offered by Honeywell. They enclose basic switches within a corrosionresistant aluminum housing to seal precision switch contacts from contamination. SE switches include a SM basic switch; XE switches include the smaller SX basic switch. Housing material: Sealing: Termination: Contacts: Aluminium Watertight seal per MIL-PRF-8805, symbol 3 305,0 mm [1 ft] leadwire or Solder (turret) Silver Switching options: SPDT Single Pole, Double Throw SPNC Single Pole, Normally Closed SPNO Single Pole, Normally Open Electrical ratings: www.honeywell.com/sensing A 5 A res., 3 A ind., (sea level), 5 A res., 2.5 A ind., [50000 ft], 28 Vdc 5 A res., 5 A ind., 125 or 250 Vac, 60 Hz B UL/CSA rating - 5A, 250 Vac, 60 Hz C 7 A res., 4 A ind., (sea level) 7 A res., 2.5 A ind., [50000 ft], 28 Vdc 7 A res., 4 A ind., (sea level) 115 Vac, 400 Hz D UL Rating - 7 A, 250 Vac, 60 Hz E 7 A res., 4 A ind., (sea level) 7 A res., 2.5 A ind., [50000 ft], 28 Vdc F 1 A res., 0.5 A ind., 28 Vdc 121 SEALED SWITCHES Top pin plunger SE Series OPTIONS Leadwire SPDT Single Pole, Double Throw Leadwire termination Solder (Turret) Package size: Operating temperature: Standard Low Approvals: Operating force max. (OF): Standard Low High Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 19,05 mm H x 8,64 mm W x 22,35 mm L [0.75 in H x 0.34 in W x 0.88 in L] -53 °C to 105 °C [-65 °F to 221 °F] -26 °C to 80 °C [-15 °F to 185 °F] UL, CSA (4SE1 only) 1,39 N to 4,73 N [5.0 oz to 17.0 oz] 1,11 N to 2,22 N [4.0 oz to 8.0 oz] 1,39 N to 5,28 N [5.0 oz to 19.0 oz] 1,27 mm [0.050 in] 0,08 mm [0.003 in] 0,10 mm [0.004 in] FEATURES Gold contacts Gold bifurcated contacts UL/CSA listing/leadwires Fluorosilicone seal/Low temperature Low OF ELECTRICAL RATING A F F B A A CAT. LISTING 1SE1 1SE7 1SE401 4SE1 5SE1 7SE1 Solder (Turret) termination FEATURES Gold contacts High OF ELECTRICAL RATING A F A CAT. LISTING 1SE1-T 1SE61-T 12SE4-T SPNC Single Pole, Normally Closed Leadwire termination ELECTRICAL RATING A CAT. LISTING 1SE2 SPNO Single Pole, Normally Open Leadwire termination ELECTRICAL RATING A 122 www.honeywell.com/sensing CAT. LISTING 1SE3 SEALED SWITCHES SE Series Auxiliary actuators (Switches must be ordered separately) Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 3,34 N [12 oz] 3,81 mm [0.150 in] 0,38 mm [0.015 in] 0,64 mm [0.025 in] Roller leaf Straight leaf CAT. LISTING JE-1 CAT. LISTING JE-5 Roller leaf , perpendicular CAT. LISTING JE-4 www.honeywell.com/sensing 123 SEALED SWITCHES Top pin plunger XE Series OPTIONS Solder (Turret) SPDT Single Pole, Double Throw Leadwire termination Leadwire Package size: Operating temperature: Standard High Low Approvals: Operating force max. (OF): Standard Low Pretravel max. (PT): Standard Low Overtravel min. (OT): Differential travel max. (DT): 19,05 mm H x 8,13 mm W x 15,75 mm L [0.75 in H x 0.32 in W x 0.62 in L] -55 °C to 85 °C [-67 °F to 185 °F] -53 °C to 149 °C [-65 °F to 300 °F] -26 °C to 85 °C [-15 °F to 185 °F] UL, CSA (4XE1 only) 1,39 N to 4,73 N [5.0 oz to 17.0 oz] 2,50 N [9 oz] 1,27 mm [0.05 0,76 mm [0.03 0,10 mm [0.004 0,13 mm [0.005 in] in] in] in] FEATURES ELECTRICAL RATING C C F Gold contacts Gold bifurcated contacts/ high temperature/1524 mm [6 ft] leadwire length Low OF/Low PT/high temperature UL/CSA listing/leadwires Fluorosilicone seal/low temperature MILITARY PART NUMBER MS27994-1 MS27994-4 MS27994-5 F E D C CAT. LISTING 1XE1 1XE201 1XE301 1XE401-6 14XE1 4XE1 5XE1 Solder (Turret) termination FEATURES Gold bifurcated contacts/ high temperature Gold contacts Low OF/Low PT/high temperature ELECTRICAL RATING A MILITARY PART NUMBER MS27994-3 F F E CAT. LISTING 1XE1-T 1XE401-T 1XE99-T 14XE1-T SPNO Single Pole, Normally Open Leadwire termination ELECTRICAL RATING C 124 www.honeywell.com/sensing MILITARY PART NUMBER CAT. LISTING 1XE3 SEALED SWITCHES XE Series Auxiliary actuators (Switches must be ordered separately) Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 5,84 N [21 oz] 3,18 mm [0.12 in] 0,23 mm [0.01 in] 0,30 mm [0.01 in] Straight leaf 10,9 0.43 CAT. LISTING JM-1 Roller leaf 16,0 0.63 CAT. LISTING JM-5 www.honeywell.com/sensing 125 SEALED SWITCHES HM Series Miniature, Hermetically Sealed, Basic Switches Integral lever OPTIONS Leadwire termination HM Series hermetically sealed basic switches contain contacts in a sealed chamber. A gas-tight seal is maintained while transmitting force and motion to the switch mechanism through a metal diaphragm. This series is not generally recommended for 115 Vac, 60 Hz. If you have a 60 Hz application in the mA range, or applications that require the switch to function electrically during exposure to sub-freezing temperatures, contact Honeywell for special design variations that are available. Package size: Housing material: Sealing: Hermetic Termination: Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Switching options: SPDT 18,29 mm H x 6,35 mm W x 22,35 L (0.72 in H x 0.25 in W x 0.88 in L] Stainless Steel MIL-PRF-8805, design symbol 5 Solder or leadwire 1,95 N [7.00 oz] 0,76 mm [0.03 in] 0,08 mm [0.003 in] 0,15 mm [0. 006 in] Single Pole, Double Throw CABLE LENGTH 152,4 mm [6 in] 304,8 mm [1 ft] 304,8 mm [1 ft] 1524,0 mm [5 ft] ELECTRICAL RATING E C B B MILITARY PART NUMBER CABLE CONTACT TEMPERATURE ELECTRICAL LENGTH MATERIAL RANGE RATING 304,8 mm [1 ft] Silver cadmium 3 B oxide MILITARY PART NUMBER [1] Electrical ratings: A 1 A res., 0.25 A ind., (sea level or 70000 ft), 28 Vdc B 4 A res., 2 A ind., (sea level), 28 Vdc C 0.5 A res., 0.25 A ind., (sea level or 70000 ft), 28 Vdc D 3 A res., 1 A ind. (sea level or 70000 ft), 28 Vdc 1 A res., or ind. (sea level), 115 Vac, 400 Hz E 0.1 A res., 0.1 A ind., 28 Vdc CONTACT MATERIAL Gold Gold Bifurcated Silver Silver MS27216-2 MS27216-4 CAT. LISTING 114HM1-2 [1] 20HM1-1 2HM19-1 2HM19-5 Mechanical life 100 000 operations Leadwire, potted Temperature range: 1 -65 °C to 121 °C [-85 °F to 257 °F] 2 -65 °C to 176 °C [-85 °F to 350 °F] 3 -65 °C to 260 °C [-85 °F to 500 °F] 4 -184 °C to 121°C [-300 °F to 250 °F] 5 -184 °C to 260 °C [-300 °F to 500 °F] Application notes 1 Honeywell does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 V and/or 0.5 A. Catalog listings in the 5, 6, 15, and16HM Series use silver cadmium oxide contacts. If you have specific questions, contact Honeywell. 2 For applications involving non-arcing loads, catalog listings in the 9, 10, 19 and 20HM Series are recommended. 126 TEMPERATURE RANGE 2 3 1 1 www.honeywell.com/sensing CAT. LISTING 6HM1-1 SEALED SWITCHES HM Series, Integral lever (continued) HM Series Auxiliary actuators Solder termination (Switches must be ordered separately) Operating force max. (OF): Overtravel min. (OT): Differential travel max. (DT): 2,50 N [9.0 oz] 0,76 mm [0.030 in] 0,76 mm [0. 030 in] Straight leaf CONTACT MATERIAL Silver Gold Gold Bifurcated Gold Bifurcated Gold Bifurcated Gold Bifurcated TEMPERATURE RANGE 4 4 5 5 4 4 ELECTRICAL RATING D A C C C C MILITARY PART NUMBER MS27216-5 MS27216-6 CAT. LISTING 11HM1 13HM1 19HM1 19HM4 [2] 9HM1 109HM1 [3] [2] Only metal and glass material exposed external to switch (i.e. vacuum application consideration) [3] Mechanical life 100 000 operations CAT. LISTING JS-254 Electrical life 25 000 operations at full rated load Roller leaf Solder, weld 8,4 .33 CAT. LISTING JS-151 Mounting plate CONTACT TEMPERATURE MATERIAL RANGE Silver cadmium oxide 3 Silver cadmium oxide 5 ELECTRICAL RATING D D MILITARY PART NUMBER CAT. LISTING 15HM2 15HM5 [2] A force spreading plate is recommended to reduce the risk of product damage due to excessive mounting force. 15,75 (0.062) 9,525 (0.375) 0,79 (0.031) 12,19 (0.48) Ø 2 x 2,39 (0.094) CAT. LISTING 19PA137-HM Notice Torque on #2 mounting screws must be restricted to 0,16 N m [1.5 in lb] max. to prevent switch damage. The force spreading mounting plate 19PA137-HM will allow up to 0,28 N m [2.5 in lb] of mounting torque. www.honeywell.com/sensing 127 SEALED SWITCHES HS Series Hermetically Sealed Basic Switches HS Series Hermetically Sealed Switches are designed for potential applications where maximum electrical rating and maximum sealing are essential, and where size and weight requirements are less critical. These switches are side-mounted through mounting holes located outside the sealed switching chamber. Package size: OPTIONS Standard 25,4 mm H x 17,8 mm W x 50,8 mm L [1.0 in H x 0.7 in W x 2.0 in L] Housing material: Stainless Steel, phenolic Sealing: Hermetic MIL-S-8805, design symbol 5 Operating temperature: Standard -55 °C to 125 °C [-67 °F to 250 °F] High -55 °C to 149 °C [-67 °F to 300 °F] Approvals: UL, CSA (screw terminals) Termination: Screw or leadwire Operating force max. (OF): 2,78 N to 6,12 N [10 oz to 22 oz] Pretravel max. (PT): 1,65 mm [0.065 in] Overtravel min. (OT): 0,25 mm [0.010 in] Differential travel max. (DT): 0,51 mm [0.020 in] Contacts: Silver Switching options: SPDT Single Pole, Double Throw Electrical ratings: 128 A 25 A res., 8 A ind., 28 Vdc 1 A res., 1 A ind, 115 Vac UL-CSA rating - 1 A, 125 Vac B 15 A res., 8 A ind., 28 Vdc 0.5 A res., 1A ind., 125 Vac C 15 A res., 8 A ind., 28 Vdc 0.5 A res., 1A ind., 125 Vac UL-CSA rating - 1 A, 125 Vac D 25 A res., 8 A ind., 28 Vdc 0.5 A res., 1 A ind., 125 Vac UL-CSA rating - 1A, 125 Vac Top roller lever Screw termination ELECTRICAL RATING A www.honeywell.com/sensing MILITARY PART NUMBER CAT. LISTING 1HS3 SEALED SWITCHES Integral lever Leadwire termination Screw termination Standard ELECTRICAL RATING A D MILITARY PART NUMBER MS25011-1 CAT. LISTING 1HS1 101HS1 ELECTRICAL RATING B MILITARY PART NUMBER CAT. LISTING 4HS4-118 High Temperature Operating force (OF): ELECTRICAL RATING C 2,78 N to 8,34 N [10 oz to 30 oz] MILITARY PART NUMBER CAT. LISTING 102HS1 Increased operating force Operating force (OF): Pretravel max. (PT): ELECTRICAL RATING A 6,12 N to 7,78 N [22 oz to 28 oz] 2,16 mm [0.85 in] MILITARY PART NUMBER MS25011-4 CAT. LISTING 1HS6 Leaf - added overtravel Operating force (OF): Pretravel max. (PT): Overtravel max. (OT): Differential travel max. (DT): ELECTRICAL RATING A 1,11 N to 5,56 N [4 oz to 20 oz] N/A 1,57 mm [0.062 in] 2,54 mm [0.100 in] MILITARY PART NUMBER CAT. LISTING 1HS41 www.honeywell.com/sensing 129 SEALED SWITCHES HT Series High Temperature Basic Switches HT Series High Temperature Switches are designed to withstand temperatures up to +538 °C [+1000 °F]. The switching element is mounted on a ceramic base with a stainless steel enclosure. Note: HT Series switches are not classified as sealed switches. Package size: Standard 31,75 mm H x 17,78 mm W x 49,78 mm L [1.25 in H x 0.70 in W x 1.96 in L] Housing material: Ceramic/Stainless Steel Sealing: No Operating temperature: 538 °C [1000 °F] Approvals: UL, CSA Termination: Screw Electrical rating: 3 A, 1/10 HP, 125 Vac 2 A, 1/6 HP, 250 Vac Switching options: SPDT Single Pole, Double Throw OPTIONS Top pin plunger, side mount Top pin plunger, panel mount Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 2,78 N to 5,6 N [10 oz 1,65 mm 4,78 mm 0,25 mm 2,78 N to 5,6 N [10 oz 1,27 mm 0,25 mm 0,25 mm to 20 oz] [0.06 in] [0.19 in] [0.01 in] CAT. LISTING 1HT1 to 20 [0.05 [0.01 [0.01 CAT. LISTING 2HT1 Top roller plunger, panel mount Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 8.34 N [30 oz] 1,65 mm [0.06 in] 4,78 mm [0.19 in] 0,254 mm [0.01 in] CAT. LISTING 3HT1 130 oz] in] in] in] www.honeywell.com/sensing SEALED SWITCHES EN Series Environment Sealed Limit Switches The EN Series Environment-sealed Limit Switch has resilient sealing as defined in MIL-S-8805, Symbol 4. In addition to the standard versions, miniature housing constructions may be available with similar actuator styles. The miniature versions may meet the demand for smaller size and lighter weight without sacrificing performance or electrical capacity. The miniature version housing is 7,92 mm [0.312 in] smaller in diameter and weighs 14,2 g [0.5 oz] less than the standard version. Housing material: Sealing: Operating temperature: Termination: Stainless Steel MIL-PRF-8805, design symbol 4 -54 °C to 85 °C [-65 °F to 185 °F] 1,829 m [6 ft] Leadwire (#18 and #20) Receptacle (bottom or side) Silver Hermetic Contacts: Switching options: DPDT Double Pole, Double Throw 2 1 3 5 4 6 4PDT 4 Pole, Double Throw 2 1 3 5 4 6 8 7 9 11 10 12 1 CKT, DB Single Pole, Double Throw, Double Break 4 3 1 2 2 CKT, DB Double Pole, Double Throw, Double Break 2 1 3 6 4 5 7 8 www.honeywell.com/sensing 131 SEALED SWITCHES Electrical Specifications The electrical ratings charted below are referenced in the order guides. Refer to Appropriate MIL specification for ratings applicable to specific switches. DC Ratings (Amps) Rating2 Sea Level Code Voltage Inrush Motor 50,000 Feet Res. Ind. Inrush Motor 3 Res. 1 Ind. A 28 Vdc 24 4 4 2 24 4 4 2 B 28 Vdc 36 6 10 3 36 63 10 3 30 3 15 10 1 .5 7 2.5 C 28 Vdc 30 D 28 Vdc 24 E 28 Vdc F 28 Vdc 5 4 N/A 24 4 15 10 5 3 1 .5 7 5 N/A N/A 4 24 4 3 Notes: 1 5 amps for rotary switches. 2 For other electrical data, contact your nearest Honeywell office, MIL-S-8805 ratings apply when this specification is invoked. 3 Application information only. AC Ratings Sea Level Rating Code Voltage A&D B C F Motor Make Break Res. Ind. 125/460 Vac @ 60 Hz 24 4 5 3 125 Vac @ 400 Hz 24 4 5 5 125/250 Vac @ 60 Hz 20 3 5 5 460 Vac @ 60 Hz 20 3 3 3 125 Vac @ 400 Hz 36 6 10 6 125/250 Vac @ 60 Hz 20 3 5 5 460 Vac @ 60 Hz 20 3 3 3 125 Vac @ 400 Hz 30 5 10 6 125/460 Vac @ 60 Hz 12 2 2 2 125 Vac @ 400 Hz 24 4 5 5 Explanations of switches with special features Low force operation (Low OF) Special spring construction within this switch reduces the normal 6 lb to 12 lb [26,7 N to 53,4 N] EN operating force to 3 lb to 6 lb[13,3 N to 26,7 N]. This switch is also dimensionally interchangeable with the standard size 1EN1-6. Low force 600 series ENs have 3 to 6 pounds [13,3 to 26,7 N] of operating force. Increased overtravel (High OT) A longer plunger and bushing on the switch extends the EN overtravel capabilities from the normal 0.25 in to 0.86 in [6,35 mm to 21,8 mm]. The longer bushing also permits additional adjustment of the plunger position. High impact shock (High shock) Catalog listing 1EN75-R3 (M8805/65-001) has been qualified to MIL-PRF-8805, including high impact shock class H. Other switches rated for high impact shock applications incorporate the same plunger mechanism and internal switch design as used in the 1EN75-R3 and are expected to conform to the same requirements. Switch dimensions Where there is no dimension drawing shown, combine housing height and diameter with actuator for overall measurement. 132 www.honeywell.com/sensing SEALED SWITCHES EN Series Standard switches Operating characteristics (except where specified otherwise ) Operating force max. (OF): 26,69 N to 53,38 N [6 lb to 12 Low 13,3 N to 26,7 N [3 lb to 6 Pretravel max. (PT): 1,02 mm [0.04 Overtravel min. (OT): 6,35 mm [0.25 High 12,7 mm [0.50 Differential travel max. (DT): 0,51 mm [0.020 lb] lb] in] in] in] in] OPTIONS Top pin plungers Bottom receptacle termination Leadwire termination Side receptacle termination Leadwire #18 wire gage Leadwire #20 wire gage Housing height 1EN1-6/1EN231-6/1EN51-6 Housing Ø 2EN/3EN/4EN Series 72,4 or 57,4 2.85 2.26 or 45,7 1.8 Pretravel Differential travel max. (PT) max. (DT) Housing Height Diameter 2EN 1,27 mm [0.05 in] 0,89 mm [0.035 in] 38,1 mm [1.50 in] 38,1 mm [1.5 in] 3EN 1,52 mm [0.06 in] 0,89 mm [0.035 in] 33,3 mm [1.31 in] 38,1 mm [1.5 in] 4EN 1,78 mm [0.07 in] 1,14 mm [0.045 in] 43,2 mm [1.70 in] 38,1 mm [1.5 in] 1EN61-6/1EN412-3 CIRCUITRY DPDT High shock Low OF High OT Gold contacts ELECTRICAL RATING A DPDT DPDT DPDT DPDT MILITARY PART NUMBER MS24331-1 A A A E CAT. LISTING CIRCUITRY ELECTRICAL DPDT 1 CKT, DB 2 CKT, DB B C C MILITARY PART RATING MS24331-2 MS24331-3 MS24331-4 CAT. LISTING NUMBER 2EN1-6 3EN1-6 4EN1-6 1EN1-6 1EN231-6 1EN51-6 1EN61-6 1EN412-3 www.honeywell.com/sensing 133 SEALED SWITCHES Ball bearing plunger EN Series Standard switches (continued) 7,9 0.31 Top pin plungers (continued) Bottom receptacle 39,1 1.54 UNEF 25,4 1.00 Leadwire #20 wire gage Housing height: Diameter: 24,9 mm [0.98 in] 25,4 mm [1.00 in] CIRCUITRY MATES WITH MIL-C-81703, MS3137E7-50S OR EQUIVALENT 1EN75-R DPDT ELECTRICAL RATING A MILITARY PART NUMBER CAT. LISTING 2001EN1-6 Top roller plunger Leadwire Bottom receptacle MATES WITH MS3106E-16S-1S 1EN75-R3 CIRCUITRY High shock High shock DPDT DPDT ELECTRICAL RATING D D MILITARY PART NUMBER M8805/65-001 CAT. LISTING 1EN75-R 1EN75-R3 Leadwire #20 wire gage Housing height: Diameter: 24,9 mm [0.98 in] 25,4 mm [1.00 in] CIRCUITRY Side receptacle 1EN76-R Gold contacts DPDT DPDT ELECTRICAL RATING A E MILITARY PART NUMBER ELECTRICAL RATING D MILITARY PART NUMBER CAT. LISTING 21EN9-6 21EN108-6 Bottom receptacle MATES WITH MIL-C-81703, MS3137E7-50S OR EQUIVALENT CIRCUITRY High shock DPDT ELECTRICAL RATING D MILITARY PART NUMBER CAT. LISTING CIRCUITRY 1EN76-R High shock 134 www.honeywell.com/sensing DPDT CAT. LISTING 21EN75-R1 SEALED SWITCHES Rotary linkage lever, adjustable rod Rotary roller lever Leadwire termination Leadwire termination Leadwire #20 wire gage Leadwire #20 wire gage Operating force max. (OF): 1,4 N m to 2,8 N m [12 in lb to 25 in lb] Pretravel max. (PT): 13° ± 3° Differential travel max. (DT): 4° Housing height: 53,6 mm [2.11 in] Diameter: 25,4 mm [1.00 in] Operating force max. (OF): Differential travel max. (DT): Housing height: Diameter: CIRCUITRY ELECTRICAL RATING D D DPDT DPDT MILITARY PART CAT. LISTING NUMBER MS21320-1 (CW) 31EN11-6 MS21320-2 (CCW) 31EN1-6 Housing Height Diameter 32EN 20° ± 4° 6° 68,6 mm [2.70 in] 38,1 mm [1.5 in] 33EN 15° ± 4° 5° 62,0 mm [2.44 in] 38,1 mm [1.5 in] 34EN 15° ± 5° 10° 71,6 mm [2.82 in] 38,1 mm [1.5 in] DPDT DPDT 1CKT DB 1CKT DB 2CKT DB 2CKT DB ELECTRICAL RATING A DPDT MILITARY PART NUMBER MS24420-1 CAT. LISTING 41EN1-6 Leadwire #18 wire gage 0,57 N m [5 in lb] 1,13 N m [10 in lb] 1,4 N m to 2,8 N m [12 in lb to 25 in lb] Pretravel Differential travel (PT) max. (DT) CIRCUITRY CIRCUITRY Operating force max. (OF): 42EN 44EN Leadwire #18 wire gage Operating force max. (OF): 0,34 N m [3 in lb] 12° 25,4 mm [1.00 in] 25,4 mm [1.00 in] ELECTRICAL RATING B B C C C C MILITARY PART NUMBER MS21320-3 (CW) MS21320-4 (CCW) MS21320-5 (CW) MS21320-6 (CCW) MS21320-7 (CW) MS21320-8 (CCW) Differential travel max. (DT) Housing Height Diameter 42EN 12° 42,2 mm [1.66 in] 38,1 mm [1.5 in] 44EN 20° 45,7 mm [1.80 in] 38,1 mm [1.5 in] CAT. LISTING CIRCUITRY DPDT 2 CKT DB ELECTRICAL RATING B C MILITARY PART NUMBER MS24420-2 MS24420-4 CAT. LISTING 42EN1-6 44EN1-6 32EN11-6 32EN1-6 33EN11-6 33EN1-6 34EN11-6 34EN1-6 www.honeywell.com/sensing 135 SEALED SWITCHES Miniature type EN switches may meet the demand for smaller size and lighter weight without sacrificing performance or electrical capacity. These types are of the same construction, seal, and materials as the standard size EN switches. EN Series Miniature switches Type 400EN switches are directly interchangeable with their standard size EN counterpart, yet are smaller in diameter and lighter in weight. The miniature listing housing is 0.312 in [7,92 mm] smaller in diameter, and the switch weight 1.2 oz [14,2g] less. Operating temperature: Top pin plunger -55 °C to 85 °C [-67 °F to 185 °F] Top roller plunger 600EN Housing height Housing Ø 400EN Housing height Housing height Housing Ø Leadwire #20 wire gage Housing Ø Housing Height 600EN 25,4 mm [1.0 in] 17,5 mm [0.69 in] 624EN 30,5 mm [1.20 in] 25,4 mm [1.0 in] CIRCUITRY Gold contacts 400EN 600EN Leadwire #20 wire gage Housing Height Diameter 402EN 24,9 mm [0.98 in] 17,5 mm [0.69in] 404EN 30,5 mm [1.20 in] 25,4 mm [1.0 in] 602EN 25,4 mm [1.0 in] 17,5 mm [0.69 in] 604EN 30,5 mm [1.200 in] 25,4 mm [1.0 in] CIRCUITRY Gold contacts Gold contacts 136 DPDT 4PDT DPDT DPDT 4PDT 4PDT ELECTRICAL RATING F F F E F E MILITARY PART NUMBER MS21321-1 MS21321-2 MS27240-1 MS27240-5 MS27240-2 MS27240-6 Diameter 622EN CAT. LISTING 402EN1-6 404EN1-6 602EN1-6 602EN222-6 604EN1-6 604EN222-6 www.honeywell.com/sensing DPDT DPDT 4PDT 4PDT ELECTRICAL RATING F E F E MILITARY PART NUMBER MS27240-3 MS27240-7 MS27240-4 MS27240-8 CAT. LISTING 622EN1-6 622EN222-6 624EN1-6 624EN222-6 SEALED SWITCHES HE Series Hermetically Sealed, Limit Switches The HE Series Hermetically-sealed Limit Switch meets hermetic sealing as defined in MIL-S-8805, Symbol 5. The HE Series features true hermetic sealing (metal-to-metal, glass-to metal construction), aimed at providing maximum sealing effectiveness for exceptionally long periods of time regardless of constant changes in atmospheric pressures and temperatures. Housing material: Sealing: Hermetic A Switching options: SPDT Top pin plunger 1HE1-6 602HE1-6 Stainless Steel MIL-S-8805, design symbol 5 -55 °C to 125 °C [-67 °F to 257 °F] Leadwire (x 6) Operating temperature: Termination: Operating force max. (OF): 1HE Series 26,69 N to 53,38 N [6 lb to 12 lb] 600HE Series 22,2 N to 53,38 N [5 lb to 12 lb] Pretravel max. (PT): 1,02 mm [0.04 in] Overtravel min. (OT): 1HE Series 6,35 mm [0.25 in] 600HE Series 3,18 mm [0.12 in] Differential travel max. (DT): 0,51 mm [0.02 in] Contacts: Electrical ratings A/B Silver Electrical rating C Gold Electrical ratings: OPTIONS 7 A res., 5 A ind., 28 Vdc B 5 A res., 3 A ind., 28 Vdc C 1 A res., 0.50 A ind., 28 Vdc Single Pole, Double Throw 604HE1-6 dimensions as 602HE1-6 except: FEATURES 3 x leadwires, gold contacts Gold contacts 12 x leadwires ELECTRICAL RATING CONTACT C B C A A SPDT DPDT DPDT DPDT 4PDT Ø 25,4 mm [1.00 in] Height 30,5 mm [1.20 in] MILITARY PART NUMBER MS8805/80-01 CAT. LISTING 1HE222-6 1HE1-6 602HE106-6 602HE1-6 604HE1-6 Top roller plunger 622HE1-6 DPDT Double Pole, Double Throw 2 1 3 5 4 6 4PDT 4 Pole, Double Throw 2 1 3 5 4 6 8 624HE1-6 dimensions as 622HE1-6 except: 7 9 11 10 FEATURES 12 x leadwires ELECTRICAL RATING A A CONTACT DPDT 4PDT Ø 25,4 mm [1.00 in] Height 30,5 mm [1.20 in] MILITARY PART NUMBER CAT. LISTING 622HE1-6 624HE1-6 12 www.honeywell.com/sensing 137 SEALED SWITCHES HR Series Hermetically Sealed, High Temperature, Limit Switches OPTIONS Top pin plunger Screw termination CONTACT DPDT The HR Series high temperature, hermetically sealed switch is sealed as defined in MIL-S-8805, Symbol 5. The HR Series combines maximum sealing, high temperature (315 °C [600 °F]) capabilities and rugged, heavy duty, corrosion-resistant construction aimed at providing reliable switching in the most demanding applications. Housing material: Sealing: Operating temperature: Hermetic Termination: Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): Contacts: Electrical rating: Switching options: SPDT MILITARY PART NUMBER MS24594-1 CAT. LISTING MILITARY PART NUMBER CAT. LISTING Leadwire termination Stainless Steel MIL-S-8805, design symbol 5 -65 °C to 315 °C [-85 °F to 600 °F] Screw or leadwire [1,83 m, 6 ft] 26,69 N to 53,38 N [6 lb to 12 lb] 1,27 mm [0.05 in] 6,35 mm [0.25 in] 0,38 mm [0. 01 in] Silver 5 A, 28 Vdc Single Pole, Double Throw CONTACT SPDT DPDT 12HR1-S Double Pole, Double Throw 2 1 12HR8-6 Top roller plunger, parallel Screw termination 3 5 4 6 CONTACT DPDT 138 www.honeywell.com/sensing MILITARY PART NUMBER CAT. LISTING 22HR1-S MANUAL SWITCHES The TL Series are military-grade design and environment-proof sealed toggle switches, qualified to MIL-S-3950. A large selection of circuitries, lever designs, and electrical terminations are available, with silver or gold plated contacts to meet a variety of electrical load requirements. They have high strength, temperature resistant, non-tracking case material. TL Series Environment Sealed Toggle Switches For options other than those shown below, contact Honeywell for more information. IWTS (Integrated Wire Termination System) option IWTS provides you with a reliable, completely serviceable unit which meets MIL-S-3950 requirements. IWTS improves maintainability since wiring bundles need not be disturbed. Leads are quickly and easily assembled or removed with an insert-extract tool. A unique three-rib (grommet style) elastomer seal protects the lead connections without potting. There are no exposed metal terminals. Versions are available that will accept No.16 wire with M39029/1-102 contact pins or No. 20 wire with M39029/1-101 contact pins. Connections are resistant to shock, vibration, and high pulling force. Standard lever - 1, 2 and 4 pole Approvals: Sealing: Operating temperature: Mounting: Termination: Contacts: Locking lever IWTS type 1 and 2 pole UL, CSA, CE MIL-S-3950 -65 °C to 71 °C [-85 °F to 160 °F] Bushing 15/32 in Solder, Screw, IWTS (14-16 Gage and 16-20 Gage) Silver cadmium oxide or gold (gold where indicated) Electrical ratings (Resistive load): Values below are based on previous Honeywell testing and opinion. See MIL-S-3950 for Military specified values. A 0.5 A to 15 A at 0.5 Vac to 277 Vac|0.75 A at 115 Vdc| 0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A at 250 Vdc B 0.5 A to 15 A at 0.5 Vdc to 28 Vdc|0.75 A at 115 Vdc| 0.5 A to 10 A at 0.5 Vac to 277 Vac|0.5 A at 250 Vdc C 0.75 A at 115 Vdc|0.5 A to 20 A at 0.5 Vdc to 28 Vdc| 0.5 A to 15 A at 0.5 Vac to 277 Vac|0.5 A at 250 Vdc D 0.5 A to 18 A at 0.5 Vdc to 28 Vdc|0.5 A to 10 A at 0.5 Vac to 277 Vac| 0.5 A at 250 Vdc|0.75 A at 115 Vdc E 0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A to 15 A at 0.5 Vac to 277 Vac| 0.5 A at 250 Vdc|0.75 A at 115 Vdc F 0.75 A at 115 Vdc|0.5 A at 250 Vdc|0.5 A to 10 A at 0.5 Vac to 277 Vac| 0.5 A to 18 A at 0.5 Vdc to 28 Vdc UL/CSA Rating Code: L191: 15 A-125, 250, 277 Vac; 1/2 Hp-125 Vac; 1 Hp-250, 277 Vac; 5 A-120 Vac “L” L192: 10 A-125, 250, 277 Vac; 1/4 Hp-125 Vac; 1/2 Hp-250, 277 Vac; 3 A-125 Vac “L” Application Note: Honeywell does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 V and/or 0.5 A. TL switches use silver cadmium oxide contact. If you have specific questions, contact Honeywell. www.honeywell.com/sensing 139 MANUAL SWITCHES Standard lever Terminal circuit identification One pole Two pole Four pole IWTS (Integrated Wire Termination System) Panel cutout With locking ring Without locking ring Note: 1,4 mm/.06in MIN DEEP TO ACCOMMODATE LOCKING RING. 15PA87 PANEL SEAL REQUIRES BLIND HOLE TO ENSURE SEAL INTEGRITY Locking lever Lever locking configurations Relates to bold digit in Cat. Listing (part number) A D E Locked In 3 Positions Locked Out of Center Position Locked In Center Position F G K Locked In Center and Locked In Locked In Extreme Position Extreme Position Extreme Position (Opposite Keyway) (Keyway Side) (Opposite Keyway) 140 www.honeywell.com/sensing MANUAL SWITCHES 2 Position Switching options/Operating action: TL Series 2 position switches SPST Standard lever 1 pole, screw terminals CIRCUITRY SPST SPST SPDT SPDT OPERATING ACTION 1 2 3 4 ELECTRICAL RATING A B A B DPST DPST OPERATING ACTION 5 6 ELECTRICAL RATING C D MILITARY PART NUMBER MS24523-22 MS24523-30 MS24523-23 MS24523-26 CAT. LISTING 1TL1-2 1TL1-6 1TL1-3 1TL1-8 DPST DPDT OPERATING ACTION 5 7 ELECTRICAL RATING C C Opposite Keyway Position 2 3 OFF 2 3 ON Keyway Position Opposite Keyway Position 1 1 MILITARY PART NUMBER MS24524-22 MS24524-30 MILITARY PART NUMBER MS27735-22 MS27735-23 CAT. LISTING UL/CSA RATING L191 L191 MILITARY PART NUMBER MS27785-22 MS27785-23 CAT. LISTING 12TL1-2 12TL1-3 1 2 OFF Keyway Momentary Position 1 2 3 ON DPST Opposite Keyway Position 2 3 ON 1 2 3 ON Double Pole, Single Throw Opposite Keyway Position Keyway Position UL/CSA RATING L191 L191 1 2 ON 4 2 3 ON CAT. LISTING 2TL1-2 2TL1-6 Opposite Keyway Position Single Pole, Double Throw 3 UL/CSA RATING L191 L192 Keyway Momentary Position 2 SPDT 2 pole, solder terminals CIRCUITRY Keyway Position 1 UL/CSA RATING L191 L192 L191 L192 2 pole, screw terminals CIRCUITRY Single Pole, SingleThrow 2 5 6 3 2 5 OFF 6 3 Keyway Momentary Position Opposite Keyway Position 1 1 6 5 ON 2 5 4 ON 2 5 4 OFF 2 pole, ITWS (16-20 Gage) CIRCUITRY DPST DPDT OPERATING ACTION 5 7 ELECTRICAL RATING C C DPDT Double Pole, Double Throw 102TL2-2 102TL2-3 4 pole, screw terminals CIRCUITRY 4PST 4PDT 4PDT OPERATING ACTION 8 9 10 ELECTRICAL RATING E E F 1 7 UL/CSA RATING L191 L191 L192 MILITARY PART NUMBER MS24525-22 MS24525-23 MS24525-26 CAT. LISTING 4TL1-2 4TL1-3 4TL1-8 Opposite Keyway Position Keyway Position 6 2 3 1 5 4 ON 6 SPST SPST SPDT SPDT SPDT ELECTRICAL RATING A A A A B 8 UL/CSA RATING L191 L191 L191 L191 L192 MILITARY PART NUMBER MS24658-22D MS24658-22G MS24658-23D MS24658-26F CAT. LISTING 1TL1-2D 1TL1-2G 1TL1-3D 1TL150-3D[1] 1TL1-8F Opposite Keyway Position DPST OPERATING ACTION 5 ELECTRICAL RATING C MILITARY PART NUMBER MS24659-22D 4PDT [1] OPERATING ACTION 9 ELECTRICAL RATING E UL/CSA RATING L191 MILITARY PART NUMBER MS24660-23D 3 2 6 5 6 5 9 8 9 8 12 11 OFF 12 11 ON Keyway Momentary Position Opposite Keyway Position 3 2 1 3 2 1 6 5 4 6 5 4 Opposite Keyway Position 3 2 1 3 2 1 6 5 4 6 5 4 9 8 7 9 8 7 12 11 ON 10 12 11 ON 10 CAT. LISTING 2TL1-2D 4 pole, screw terminals CIRCUITRY 2 4 Pole, Double Throw Keyway Position UL/CSA RATING L191 3 4PDT 2 pole, screw terminals CIRCUITRY 5 4 ON 4 Pole, Single Throw Locking lever 1 pole, screw terminals OPERATING ACTION 1 1 3 3 4 3 4PST Keyway Position CIRCUITRY 2 CAT. LISTING 9 9 8 7 9 8 7 12 11 ON 10 12 11 ON 10 10 4TL1-3D FAA-PMA approved, white resilient cap on lever www.honeywell.com/sensing 141 MANUAL SWITCHES 3 Position Switching options/Operating action: TL Series 3 position switches SPST Standard lever 1 pole, screw terminals CIRCUITRY SPST SPST SPDT SPDT SPDT OPERATING ACTION 11 12 13 14 15 SPST OPERATING ACTION 11 Keyway Position 2 3 OFF 2 3 ON 11 ELECTRICAL RATING A B A B B UL/CSA RATING L191 L192 L191 L192 L192 MILITARY PART NUMBER MS24523-24 MS24523-28 MS24523-21 MS24523-31 MS24523-27 1TL1-21 1TL1-61 1TL1-1 1TL1-5 1TL1-7 SPDT UL/CSA RATING L191 MILITARY PART NUMBER MS27722-24 CAT. LISTING Keyway Position Center Position Opposite Keyway Position 1 1 1 DPST DPDT DPDT DPDT DPDT DPDT DPDT DPDT DPDT DPDT DPDT OPERATING ACTION 16 17 20 24 17 26 22 23 25 21 18 UL/CSA RATING L191 L191 L191 L191 L191 L192 L192 L192 L192 L192 L192 MILITARY PART NUMBER MS24524-24 MS24524-21 MS27407-4 MS27407-1 MS24524-23 MS24524-31 MS27407-5 MS27407-2 MS24524-27 MS27407-6 MS24524-26 CAT. LISTING 2 3 OFF 101TL1-21 Opposite Keyway Position 1 1 2 3 ON OPERATING ACTION 27 2TL1-21 2TL1-1 2TL1-10 2TL1-12 2TL1-3 2TL1-5 2TL1-50 2TL1-56 2TL1-7 2TL1-70 2TL1-8 SPDT SPDT OPERATING ACTION 13 15 DPDT DPDT DPDT DPDT DPDT DPDT DPDT OPERATING ACTION 17 20 17 17 19 21 18 Opposite Keyway Momentary Position 1 1 2 3 ON 1 2 3 OFF Center Maintained Position 16 ELECTRICAL RATING F UL/CSA RATING L192 MILITARY PART NUMBER MS24525-27 CAT. LISTING 4TL1-7 1 17 ELECTRICAL RATING A B UL/CSA RATING L191 L192 MILITARY PART NUMBER MS24658-21A MS24658-27E CAT. LISTING 1TL1-1A 1TL1-7E ELECTRICAL RATING C C C C C D D UL/CSA RATING L191 L191 L191 L191 L191 L192 L192 MILITARY PART NUMBER MS24659-21A MS27408-4A MS24659-23D MS24659-23G MS24659-33K MS27408-6E MS24659-26F 19 Opposite Keyway Momentary Position Center Position 1 2 3 1 2 3 1 2 3 6 5 4 6 5 4 6 5 4 9 8 7 9 8 7 9 8 7 1 5 4 ON 6 2 3 2 3 2 6 5 6 5 21 2 1 3 2 1 6 5 4 6 5 4 20 Center Maintained Position Opposite Keyway Momentary Position 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 Center Maintained Position Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 6 5 4 ON 6 2 3 1 5 4 OFF 6 www.honeywell.com/sensing 22 24 Opposite Keyway Momentary Position Center Position 1 1 5 4 ON 6 2 3 5 4 ON 3 5 4 ON Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 Center Maintained Position Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 Keyway Maintained Position Center Maintained Position Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 Keyway Momentary Position 26 2 Center Maintained Position Keyway Momentary Position 1 3 3 2 6 2 2 1 18 3 1 Opposite Keyway Position Keyway Maintained Position 3 Keyway Momentary Position Keyway Momentary Position 5 4 ON Center Maintained Position Keyway Momentary Position 23 3 Opposite Maintained Keyway Position Keyway Momentary Position 25 12 11 10 12 11 10 12 11 10 ON OFF ON 3 CAT. LISTING 2TL1-1A 2TL1-10A 2TL1-3D 2TL1-3G 2TL1-31K 2TL1-70E 2TL1-8F 2 3 ON Opposite Maintained Keyway Position Opposite Keyway Position 2 6 Keyway Momentary Position 142 2 3 ON Double Pole, Double Throw Keyway Position 3 Position Switching options/Operating action (continued) 4PDT 4 Pole, Double Throw 27 2 3 OFF Double Pole, Single Throw 2 pole, screw terminals CIRCUITRY 1 Keyway Momentary Center Position Position DPST Locking lever 1 pole, screw terminals CIRCUITRY 2 3 ON 15 ELECTRICAL RATING C C C C C D D D D D D 4 pole, screw terminals CIRCUITRY 1 2 OFF Keyway Momentary Center Position Position DPDT 4PDT 1 2 ON 14 2 3 ON 2 pole, screw terminals CIRCUITRY Opposite Keyway Position Single Pole, Double Throw 13 ELECTRICAL RATING A Keyway Momentary Position 12 CAT. LISTING 1 pole, ITWS (14-16 Gage) CIRCUITRY Single Pole, SingleThrow Opposite Keyway Position 1 6 2 Opposite Keyway Position Center Position 3 1 5 4 ON 6 2 3 1 5 4 OFF 6 2 3 5 4 ON MANUAL SWITCHES TW Series Environment Sealed, Miniature Toggle Switches Standard Standard, 1/4 in bushing Locking 15/32 in bushing TW Series toggle switches are miniature, military grade design and environment-proof sealed. With silver or gold contacts to meet a variety of electrical load requirements, options available include IWTS (integrated wire termination system) versions, a large selection of circuitries, electrical terminations, lever, and bushing designs. Contact Honeywell for more information. Sealing: Operating temperature: Mounting: Termination: Contacts: MIL-S-83731(1TW1-3 not sealed) -65 °C to 71 °C [-85 °F to 160 °F] Bushing 15/32 in or 1/4 in Solder Fine silver or gold (gold where indicated) Electrical ratings* (Resistive load): 0.1 A to 5.0 A at 0.5 Vac to 115 Vac| 0.1 A to 5.0 A at 0.5 Vdc to 28 Vdc * Values are based on previous Honeywell testing and opinion. See MIL-S-83731 for Military specified values. Standard lever, 15/32 in bushing Standard lever, 1/4 in bushing Panel cutout, 1/4 in bushing Locking lever, 15/32 in bushing Without locking ring With locking ring Special design - black button Button 18,03 (0.71) Max. Keyway 12,70 (0.50) 11,94 (0.470) Panel cutout, 15/32 in bushing 13,335 (0.525) Max. 2,54 (0.100) Min. Ø12,95 (0.51) Shoulder on bushing 18,80 (0.740) Max. Ø 1,78 (0.07) 2,5 (0.10) 13,59 (0.535) Max. 15,60 (0.575) Max. Terminal circuit identification Without locking ring With locking ring Note: 1,1 mm/.05 in min. deep to accommodate locking ring. For switches using panel seal, do not allow thru hole mounting. www.honeywell.com/sensing 143 MANUAL SWITCHES TW Series 2 position switches TW Series 3 position switches Standard lever Standard lever CIRCUITRY SPST Gold plated contacts SPST SPDT Gold plated contacts SPDT DPDT Gold plated contacts DPDT Solder T2 type DPDT OPERATING ACTION 1 1 2 2 3 2 3 MILITARY PART NUMBER MS27718-22-1 CIRCUITRY CAT. LISTING 11TW1-2 11TW8-2 11TW1-3 11TW8-3 12TW1-3 12TW8-3 12TW75-3 MS27718-23-1 MS27719-23-1 OPERATING ACTION 6 5 6 7 10 8 9 8 8 MILITARY PART NUMBER MS27718-27-1 SPDT OPERATING ACTION 4 MILITARY PART NUMBER MS27720-21-1L 11TW1-1L DPDT 10 MS27754-39M 12TW1-50M SPDT Gold plated contactsSPDT Gold plated contactsSPDT DPDT DPDT DPDT DPDT Gold plated contactsDPDT Solder T2 type DPDT CAT. LISTING 11TW1-7 11TW8-5 11TW8-7 12TW1-1 12TW1-50 12TW1-7 12TW1-70 12TW8-7 12TW75-7 MS27719-21-1 MS27753-39 MS27719-27-1 MS27753-40 Standard lever, unsealed CIRCUITRY Bushing 1/4 in SPDT OPERATING ACTION 2 MILITARY PART NUMBER MS27716-23-1 CAT. LISTING Locking lever CIRCUITRY 1TW1-3 Locking lever CIRCUITRY SPDT DPDT OPERATING ACTION 2 3 MILITARY PART NUMBER MS27720-23-1D MS27721-23-1D CAT. LISTING 11TW1-3D 12TW1-3D Special design lever - black button CIRCUITRY OPERATING ACTION 7 8 DPDT DPDT 2 Position Switching options/Operating action: SPST CAT. LISTING MILITARY PART NUMBER CAT. LISTING 12TW29-1 12TW29-7 Single Pole, Single Throw Keyway Position Opposite Keyway Position 2 3 OFF 2 3 ON 3 Position Switching options/Operating action: SPDT Single Pole, Double Throw 1 SPDT Single Pole, Double Throw Keyway Position Opposite Keyway Position 1 1 Keyway Position Center Position Opposite Keyway Position 1 1 1 4 Keyway Momentary Center Position Position Opposite Keyway Position 1 1 5 2 3 ON 2 3 OFF 2 3 ON 2 2 3 ON DPDT 2 3 ON Double Pole, Double Throw 3 1 6 2 3 1 5 4 ON 6 2 5 4 ON Lever locking configurations 1 6 Relates to bold digit in Cat. Listing (part number) L 1 1 2 3 ON 1 2 3 OFF 2 Opposite Keyway Position Center Position 3 1 5 4 ON 6 2 3 1 5 4 OFF 6 M Keyway Momentary Position Locked Out of and Into Locked In Locked Out of Extreme Position Extreme Position Center Position (Keyway Side) (Opposite Keyway) 144 Opposite Keyway Momentary Position 2 3 ON 9 2 3 ON Double Pole, Double Throw Keyway Position 7 D 2 3 OFF Keyway Momentary Center Position Position DPDT 3 1 6 Opposite Keyway Position Keyway Position 2 3 ON 2 Keyway Momentary Position 3 5 4 ON Center Maintained Position Opposite Keyway Momentary Position 1 6 2 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 10 Center Position 3 1 5 4 ON 6 Keyway Momentary Position 3 www.honeywell.com/sensing 8 Opposite Keyway Momentary Position 2 3 1 5 4 OFF 6 2 3 5 4 ON Center Maintained Position Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 MANUAL SWITCHES AT Series Toggle Switch Assemblies Standard The AT Series provides multi-pole (2, 4, 6, 8 &10) toggle switches that contain precision basic switches which conserve space and weight. The AT Series offers a standard lever design along with lever-locking mechanisms that are sometimes required to prevent inadvertently actuating the toggle lever when it is not desired to do so. The lever-locking mechanisms require that the toggle lever must be pulled approximately 2,3 mm [0.09 inches] to change the position. Other variations include different toggle lever designs/styles, circuitry variation, toggle lever to bushing seals, etc. The 60AT Series offers qualified versions that meet MIL-S-8805/98 requirements. To find out more about the AT Series variations that are available, contact Honeywell or visit www.honeywell.com/sensing. Sealing: MIL-S-8805/98 Switching options/Operating action: SPDT Pull-to-unlock Single Pole, Double Throw Maintained Maintained NC COM NO ON NC COM NO ON 4PDT, 2 Position 4 Pole, Double Throw Keyway Maintained Opposite Keyway Maintained NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO ON NC COM NO OFF 4PDT, 3 Position 4 Pole, Double Throw Opposite Keyway Momentary Keyway Momentary Center Maintained NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO ON NC COM NO ON NC COM NO ON Electrical ratings (Resistive load): Values below are based on previous Honeywell testing and opinion. See MIL-S-8805/98 for Military specified values. www.honeywell.com/sensing A 0.1 A to1.0 A @ 0.5 Vdc to 28 Vdc 0.1 A to 1.0 A @0.5 Vac to 115 Vac B 0.1 A to 7.0 A @ 0.5 Vdc to 28 Vdc 145 MANUAL SWITCHES AT Series 2 toggle positions AT Series 3 toggle positions Standard lever SPDT Locking lever 4PDT 40˚ Approx. Total Travel Ø 3,96 (0.156) 1/4-40 UNS Thread 21,08 (0.83) 9,40 (0.37) 16,66 (0.656) Hex nut 16,0 (0.63) 17,0 0.67 19,80 (0.78) 9,525 (0.375) Electrical rating: Mounting: Gold contacts A Bushing ¼ in TERMINATION Solder T type CAT. LISTING 6AT124-T 4PDT Electrical rating: Mounting: A Bushing 15/32 in TERMINATION H58 Gold contacts/FAA-PMA approved Panel Cutout 1 /4 in Bushing 6,096 Ø 0.024 17,27 0.68 15 /32 in Bushing 17,0 0.67 Electrical rating: Mounting: Silver contacts/FAA-PMA approved 146 B Bushing 15/32 in TERMINATION Quick Connect CAT. LISTING 64AT22-3 www.honeywell.com/sensing CAT. LISTING 64AT34-7E MANUAL SWITCHES ET Series Toggle Switches Environmentally sealed, magnetically held toggle switch. A holding coil replaces mechanical holding mechanism to maintain the toggle in an operate position. Available with silver or gold contacts to meet a variety of electrical load requirements. Sealing: Operating temperature: Standard Pull-to-unlock MIL-S-5594 -65 °C to 71 °C [-85 °F to 160 °F] Mounting: Bushing 15/32 in Termination: Connector MS 27478Y10E35P Leadwire 1,83 m [6 ft], #20 wire per MIL-W-5086 Screw 4 x 48 UNF x 0.188 Solder (turret) Plated, use up to #14 wire Contacts: Silver or gold (gold where indicated) Switching options/Operating action: SPDT Single Pole, Double Throw Opposite Keyway Position Solder Screw Leadwire 2 1 ON Keyway Position 3 2 1 ON DPDT 3 Double Pole, Double Throw Opposite Keyway Position Standard Keyway Position 2 1 ON 3 2 1 ON 3 5 4 ON 6 5 4 ON 6 4PDT 4 Single Pole, Double Throw Momentary Opposite Keyway Position Mechanically Maintained Center Position Electrically Maintained Keyway Position Pull-to-unlock Electrical ratings (Resistive load): Values below are based on previous Honeywell testing and opinion. See MIL-S-5594 for Military specified values. A 0.1 A to 4.0 A @ 0.5 Vdc to 28 Vdc B 0.1 A to 7.0 A @ 0.5 Vdc to 28 Vdc C 0.1 A to 5.0 A @ 0.5 Vdc to 28 Vdc 0.1 A to 5.0 A @0.5 Vac to 115 Vac D 0.1 A to 1.0 A @ 0.5 Vdc to 28 Vdc www.honeywell.com/sensing 147 MANUAL SWITCHES ET Series 2 toggle positions ET Series 3 toggle positions Standard lever SPDT Standard lever DPDT Electrical rating: A D Gold contacts TERMINATION Gold contacts Leadwire Leadwire Leadwire Screw Solder T type Solder T type MILITARY PART NUMBER M5594/1-1 M5594/1-6 M5594/1-4 M5594/1-3 M5594/1-2 Electrical rating: CAT. LISTING TERMINATION 25ET61-6 25ET64-6 25ET62-6 25ET61-S 25ET61-T 25ET117-T Gold contacts MILITARY PART NUMBER M5594/3-1 Solder T type Solder T type TERMINATION Gold (Bifurcated) contacts Solder T type Solder T type Solder T type MILITARY PART NUMBER M5594/2-1 M5594/2-2 27ET61-T 27ET71-T Electrical rating: C TERMINATION A D Gold contacts CAT. LISTING 4PDT DPDT Electrical rating: B D Gold contacts Side exit metal tube MILITARY PART NUMBER Leadwire CAT. LISTING 29ET3 CAT. LISTING Locking lever DPDT 26ET61-T 26ET65-T 26ET107-T Electrical rating: B D Gold contacts TERMINATION Locking lever SPDT Electrical rating: A TERMINATION MILITARY PART NUMBER Solder T type Screw MILITARY PART NUMBER M5594/6-1E CAT. LISTING 25ET1-T-F 25ET61-S-F Lever locking configurations Relates to bold digit in Cat. Listing (part number) DPDT Electrical rating: A TERMINATION Solder T type Connector 148 Gold contacts Leadwire Solder T type Solder T type Solder T2 type MILITARY PART NUMBER CAT. LISTING 26ET1-T-F 26ET1-R-F www.honeywell.com/sensing CAT. LISTING 27ET2-6-E 27ET61-T-E 27ET71-T-E 27ET118-T2-N MANUAL SWITCHES NT Series Sealed Toggle Switches Step base, Panel stand-off NT Series toggle switches can meet the need for a rugged, cost-effective toggle switch. Quality construction features include a seal between the toggle lever and bushing, and between the cover and case. These switches can be used where panels are subject to splashes, hosedowns, or outdoor environments. The “Easy-Start” threaded bushing enables quick alignment of mounting nut to decrease the chance of cross threading. The panel stand-off with O-ring feature available on some listings, eliminates the need for behind-the-panel hardware, provides uniform panel height, and provides a panel to cover seal. Locking toggle levers prevent accidental toggle movement. The knobbed, toggle lever must be pulled out to change position. Approvals: Sealing: Operating temperature: Step base, no hardware Mounting: Termination: Contacts: Flat base, Panel stand-off UL, CSA IP 67/68, NEMA 3, 3R, 4, 13 -40 °C to 71 °C [-40 °F to 160 °F] Bushing 15/32 in Solder, Screw, Quick Connect Silver cadmium oxide (Gold option available) Note: Electrical ratings (Resistive load): Values below are based on previous Honeywell testing and opinion. No hardware indicates no mounting nuts, keying washer, lockwasher or termination screws (if applicable). A 0.5 A to 15 A at 0.5 Vac to 277 Vac|0.75 A at 115 Vdc| 0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A at 250 Vdc B 0.5 A to 10 A at 0.5 Vac to 277 Vac|0.5 A to 15 A at 0.5 Vdc to 28 Vdc| 0.5 A at 250 Vdc|0.75 A at 115 Vdc C 0.75 A at 115 Vdc|0.5 A to 20 A at 0.5 Vdc to 28 Vdc| 0.5 A to 15 A at 0.5 Vac to 277 Vac|0.5 A at 250 Vdc D 0.5 A to 18 A at 0.5 Vdc to 28 Vdc|0.5 A to 10 A at 0.5 Vac to 277 Vac| 0.5 A at 250 Vdc|0.75 A at 115 Vdc E 0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A to 15 A at 0.5 Vac to 277 Vac| 0.5 A at 250 Vdc|0.75 A at 115 Vdc UL/CSA Rating Code: L191: 15 A-125, 250, 277 Vac; 1/2 Hp-125 Vac; 1 Hp-250, 277 Vac; 5 A-120 Vac “L” L192: 10 A-125, 250, 277 Vac; 1/4 Hp-125 Vac; 1/2 Hp-250, 277 Vac; 3 A-125 Vac “L” Application Note: Honeywell does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 V and/or 0.5 A. NT switches use silver cadmium oxide contacts, but gold contact options are available. If you have specific questions, contact Honeywell. www.honeywell.com/sensing 149 MANUAL SWITCHES NT Series, Step base switches Terminal circuit identification Standard lever One pole Two pole DIM "A" 1 pole 2 & 4 pole 29,5 mm (1.16 in) 34,4 mm (1.35 in) Four pole NOTES: 1. Locking levers have 10,7 mm (0.42 in) Ø 2. Locking ring, lockwasher, 2 hexnuts and terminal screws are provided unassembled Panel stand off toggle To order an NT Series toggle switch with panel stand-off feature, insert “6” in front of any standard listing. Example: to order panel stand-off version of standard bushing 1NT1-7, alter number to 61NT1-7. Panel cutout Ø 6,10 (0.24) 17,02 (0.67) 12,45 (0.49) 1,52 (0.06) 7,37 (0.29) With locking ring B A 1 pole 2 pole DIM "A" 29,5 mm (1.16 in) 34,4 mm (1.35 in) Solder terminals 7,6 0.3 5,3 0.21 150 Without locking ring Note: 1,4 mm/.06in MIN DEEP TO ACCOMMODATE LOCKING RING. 15PA87 PANEL SEAL REQUIRES BLIND HOLE TO ENSURE SEAL INTEGRITY 3,2 0.12 DIM "B" 23,11 mm (0.91 in) 27,94 mm (1.10 in) Lever locking configurations Quick Connect terminals Relates to bold digit in Cat. Listing (part number) A D Locked In 3 Positions Locked Out of Center Position www.honeywell.com/sensing E G L Locked Out of Locked In Locked In Extreme Position Extreme Position Center Position (Keyway Side) (Keyway Side) MANUAL SWITCHES NT Series, Step base, 2 position switches 2 Position Switching options/Operating action* (1 to 8): Standard lever 1 pole, screw terminals No hardware No hardware CIRCUITRY ACTION* SPST SPST SPDT SPDT SPDT SPDT OPERATING RATING 1 2 3 3 4 4 SPST ELECTRICAL RATING A B A A B B UL/CSA L191 L192 L191 L191 L192 L192 SPST OPERATING ACTION* 2 ELECTRICAL RATING A 1NT1-2 1NT1-6 1NT1-3 1NT1-3-NH 1NT1-8 1NT1-8-NH SPST SPDT OPERATING ACTION* 1 3 ELECTRICAL RATING A A Opposite Keyway Position 2 3 OFF 2 3 ON SPDT UL/CSA RATING L191 CAT.LISTING 1NT91-2 UL/CSA RATING L191 L191 CAT.LISTING Keyway Position Opposite Keyway Position 1 1 3 1 2 3 ON DPST No hardware No hardware DPST DPDT DPDT DPDT DPDT CAT.LISTING ELECTRICAL RATING C UL/CSA RATING L191 CAT.LISTING 2NT1-2 2NT1-3 2NT1-3-NH 2NT1-8 2NT1-8-NH 2 DPDT OPERATING ACTION* 6 3 2 5 OFF 6 3 Opposite Keyway Position 1 6 2 3 1 5 4 ON 6 2 Keyway Momentary Position 3 1 7 5 4 ON 2 6 4PDT 4PDT OPERATING ACTION* 8* UL/CSA RATING L191 CAT.LISTING 3 2 1 3 2 1 4NT1-3 6 5 4 6 5 4 9 8 7 9 8 7 12 11 ON 10 12 11 ON 10 8 4 pole, solder terminals CIRCUITRY 4PDT OPERATING ACTION 8* ELECTRICAL RATING E UL/CSA RATING L191 CAT.LISTING ELECTRICAL RATING A A UL/CSA RATING L191 L191 CAT.LISTING 3 1 5 4 ON 6 2 3 5 4 ON Opposite Keyway Position Keyway Position ELECTRICAL RATING E Opposite Keyway Position 4 Pole, Double Throw 4 pole, screw terminals CIRCUITRY 2 3 ON Double Pole, Double Throw Keyway Position 12NT1-3 1 5 ON DPDT 6 CIRCUITRY 2 3 ON Opposite Keyway Position Keyway Position 2 pole, solder terminals Opposite Keyway Position Double Pole, Single Throw 5 UL/CSA RATING L191 L191 L191 L192 L192 1 2 OFF 4 2 3 ON 11NT1-2 11NT1-3 ELECTRICAL RATING C C C D D 1 2 ON Keyway Momentary Position 6 OPERATING ACTION* 5 6 6 7 7 Opposite Keyway Position Single Pole, Double Throw 2 pole, screw terminals CIRCUITRY Keyway Momentary Position 2 1 1 pole, solder terminals CIRCUITRY Keyway Position CAT.LISTING 1 pole, Quick Connect terminals CIRCUITRY Single Pole, SingleThrow 14NT1-3 Locking lever 1 pole, screw terminals CIRCUITRY SPST SPDT OPERATING ACTION* 1 3 1NT1-2G 1NT1-3D * Operating action 1 to 8 www.honeywell.com/sensing 151 MANUAL SWITCHES NT Series, Step base, 3 position switches 3 Position Switching options/Operating action** (9 to 18): Standard lever 1 pole, screw terminals CIRCUITRY No hardware Panel stand off SPDT SPDT SPDT SPDT SPDT SPDT OPERATING ACTION** 9 10 11 11 11 11 SPDT ELECTRICAL RATING A B B B B D UL/CSA RATING L191 L192 L192 L192 L191 L192 Single Pole, Double Throw CAT. LISTING 1NT1-1 1NT1-5 1NT1-7 1NT1-7-NH 1NT231-7 61NT1-7 Keyway Position Center Position Opposite Keyway Position 1 1 1 SPDT OPERATING ACTION** 11 ELECTRICAL RATING B UL/CSA RATING L192 2 3 ON 2 3 OFF No hardware SPDT SPDT OPERATING ACTION** 11 11 ELECTRICAL RATING B B UL/CSA RATING L192 L192 CAT. LISTING 1 1 No hardware No hardware Gold contacts/ long lever DPDT DPDT DPDT DPDT DPDT DPDT DPDT DPDT DPDT DPDT OPERATING ACTION** 12 12 13 17 15 16 16 14 16 14 1 12 ELECTRICAL RATING C C C D D D D D D D UL/CSA RATING L191 L191 L191 L192 L192 L192 L192 L192 L192 L192 CAT. LISTING UL/CSA RATING L192 CAT. LISTING 2NT1-1 2NT1-1-NH 2NT1-10 2NT1-5 2NT1-50 2NT1-7 2NT1-7-NH 2NT1-70 2NT231-7 2NT889-70 2 3 OFF 2 3 ON 2 3 ON 1 2 3 OFF Opposite Keyway Position 2 6 3 1 5 4 ON 6 Keyway Momentary Position 14 2 3 ON Double Pole, Double Throw Keyway Position CIRCUITRY 1 Opposite Keyway Momentary Position DPDT 11NT1-7 11NT1-7-NH 2 pole, screw terminals 1 2 3 ON 11 1NT91-7 CAT. LISTING 1 2 3 ON Keyway Momentary Center Position Position 1 pole, solder terminals CIRCUITRY Opposite Keyway Position 10 9 1 pole, Quick Connect terminals CIRCUITRY Keyway Momentary Center Position Position 2 Keyway Maintained Position 3 13 5 4 ON Center Maintained Position Opposite Keyway Momentary Position 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 15 Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 Keyway Momentary Position 3 Center Maintained Position Center Maintained Position Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 2 pole, Quick Connect terminals CIRCUITRY DPDT OPERATING ACTION** 16 ELECTRICAL RATING D Keyway Momentary Position 2NT91-7 16 4 pole, screw terminals CIRCUITRY 4PDT OPERATING ACTION** 18 1 6 ELECTRICAL RATING E UL/CSA RATING L191 2 Opposite Keyway Momentary Position Center Position 3 1 5 4 ON 6 2 3 1 5 4 OFF 6 2 Keyway Momentary Position 3 17 1 6 5 4 ON 2 3 1 5 4 ON 6 SPDT SPDT UL/CSA RATING L192 L191 4PDT OPERATING ACTION** 18 1NT1-7E 1NT20-7E 1 2 3 1 2 3 1 2 3 6 5 4 6 5 4 6 5 4 9 8 7 9 8 7 9 8 7 18 12 11 10 12 11 10 12 11 10 ON OFF ON ELECTRICAL RATING E UL/CSA RATING L191 CAT. LISTING 4NT1-1A **Operating action 9 to 18 152 Opposite Keyway Position Center Position CAT. LISTING 4 pole, screw terminals CIRCUITRY 1 5 4 OFF 6 2 3 5 4 ON 4 Pole, Double Throw Keyway Position ELECTRICAL RATING B B 3 4NT1-1 Locking lever 1 pole, screw terminals OPERATING ACTION** 11 11 2 CAT. LISTING 4PDT CIRCUITRY Opposite Keyway Position Center Position www.honeywell.com/sensing MANUAL SWITCHES NT Series, Flat base switches NT Series, Flat base, 2 position switches Standard lever 1 pole, Quick Connect terminals CIRCUITRY SPST SPST SPDT OPERATING ACTION 1 2 3 ELECTRICAL RATING A B A UL/CSA RATING L191 L192 L191 CAT. LISTING UL/CSA RATING L191 L191 CAT. LISTING UL/CSA RATING L191 CAT. LISTING 31NT91-2 31NT91-6 31NT91-3 2 pole, Quick Connect terminals CIRCUITRY DPST DPDT OPERATING ACTION 4 5 ELECTRICAL RATING C C 32NT91-2 32NT91-3 Locking lever 1 pole, Quick Connect terminals CIRCUITRY DPDT OPERATING ACTION 5 ELECTRICAL RATING C 32NT291-3G 2 Position Switching options/Operating action: SPST Single Pole, Single Throw Keyway Position Opposite Keyway Position 2 3 OFF 2 3 ON 1 Keyway Momentary Position Opposite Keyway Position 1 2 ON 1 2 OFF 2 SPDT Single Pole, Double Throw Keyway Position Opposite Keyway Position 1 1 3 2 3 ON 2 3 ON DPST Double Pole, Single Throw Opposite Keyway Position Keyway Position 2 4 6 3 5 OFF 2 6 3 5 ON DPDT Double Pole, Double Throw Opposite Keyway Position Keyway Position 5 1 6 www.honeywell.com/sensing 2 3 1 5 4 ON 6 2 3 5 4 ON 153 MANUAL SWITCHES NT Series, Flat base, 3 position switches Standard lever 1 pole, Quick Connect terminals CIRCUITRY OPERATING ACTION 6 7 SPDT SPDT ELECTRICAL RATING A B UL/CSA RATING L191 L192 CAT. LISTING UL/CSA RATING L191 L192 L192 CAT. LISTING UL/CSA RATING L192 L192 CAT. LISTING 31NT91-1 31NT91-7 2 pole, Quick Connect terminals CIRCUITRY OPERATING ACTION 8 10 10 DPDT DPDT DPDT No hardware ELECTRICAL RATING C D D 32NT91-1 32NT91-7 32NT91-7-NH Locking lever 2 pole, Quick Connect terminals CIRCUITRY OPERATING ACTION 11 9 DPDT DPDT ELECTRICAL RATING D D 32NT291-5E 32NT94-70L 3 Position Switching options/Operating action: SPDT Single Pole, Double Throw Keyway Position Center Position Opposite Keyway Position 1 1 1 6 2 3 ON 2 3 OFF 2 3 ON Keyway Momentary Center Position Position Opposite Keyway Momentary Position 1 1 7 2 3 ON 1 2 3 OFF DPDT Double Pole, Double Throw Keyway Position 1 8 6 2 1 3 1 5 4 ON 6 6 154 2 Opposite Keyway Position Center Position Keyway Momentary Position 10 2 3 ON 2 3 1 5 4 OFF 6 1 5 4 ON 6 2 3 9 5 4 ON Opposite Keyway Momentary Position Center Position 3 2 Keyway Momentary Position 3 1 5 4 OFF 6 2 3 5 4 ON Opposite Keyway Momentary Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 Keyway Momentary Position 11 Center Maintained Position 1 6 2 Opposite Keyway Position Center Position 3 1 5 4 ON 6 2 3 1 5 4 OFF 6 2 3 5 4 ON www.honeywell.com/sensing MANUAL SWITCHES TS Series Toggle Switches TS Series switches may be used in applications where manual operation is desired. Special on-on-on circuitry can also be furnished. They have 2- or 3-position, momentary and maintained action switches with 1- and 2-pole circuitry. Switches have solder, screw or quick-connect terminations. Approvals: Operating temperature: UL, CSA -54 °C to 71 °C [-65 °F to 160 °F] Bushing 15/32 in Bright nickel Solder, Screw, Quick Connect Silver tin oxide and indium oxide Mounting: Lever/bushing material: Termination: Contacts: Electrical ratings* (Resistive load): 0.4 A to 10 A at 126 Vac to 277 Vac| 0.4 A to 20 A at 0.5 Vac to 125 Vac * Values are based on previous Honeywell testing and opinion. UL/CSA Rating Code: L311: 10 A 277 Vac, 20 A 125 Vac; 3/4 Hp-125, 250 Vac L312: 10 A 277 Vac, 20 A 125 Vac; 11/2 Hp-125, 250 Vac 11TS One pole 12TS Two pole Panel cutout Without locking ring www.honeywell.com/sensing With locking ring 155 MANUAL SWITCHES TS Series 2 position switches TS Series 3 position switches Standard lever Screw terminals Standard lever Screw terminals CIRCUITRY OPERATING ACTION 1 2 4 5 SPST SPST DPST DPDT UL/CSA RATING L311 L311 L312 L312 CAT. LISTING CIRCUITRY OPERATING SPDT SPDT DPDT 6 7 8 LISTING 11TS15-2 11TS15-6 12TS15-2 12TS15-3 UL/CSA ACTION L311 L311 L312 CAT. RATING 11TS15-1 11TS15-7 12TS15-7 UL/CSA ACTION L311 L312 CAT. RATING 11TS95-7 12TS95-10 Quick Connect terminals Quick Connect terminals CIRCUITRY OPERATING ACTION 1 5 SPST DPDT UL/CSA RATING L311 L312 CAT. LISTING LISTING 11TS95-2 12TS95-3 Furnished unassembled CIRCUITRY OPERATING SPDT DPDT 7 9 3 Position Switching options/Operating action: Solder terminals SPDT CIRCUITRY OPERATING ACTION 3 5 SPDT DPDT Furnished unassembled UL/CSA RATING L311 L312 Single Pole, Double Throw CAT. LISTING 11TS115-3 12TS115-3 Keyway Position Center Position Opposite Keyway Position 1 1 1 6 Keyway Momentary Center Position Position Opposite Keyway Momentary Position 1 1 7 2 3 ON 2 3 OFF 2 3 ON 2 Position Switching options/Operating action: SPST Single Pole, Single Throw Opposite Keyway Position Keyway Position 1 Keyway Momentary Position Opposite Keyway Position 1 2 ON 1 2 OFF DPDT 2 3 ON 8 1 6 SPDT Single Pole, Double Throw Keyway Position Opposite Keyway Position 1 1 2 DPST 3 1 5 4 ON 6 2 3 1 5 4 OFF 6 2 4 6 Opposite Keyway Position 3 5 OFF 2 6 DPDT 3 5 ON Double Pole, Double Throw Opposite Keyway Position Keyway Position 5 1 6 156 2 3 ON Double Pole, Single Throw Keyway Position 2 3 1 5 4 ON 6 2 Opposite Keyway Momentary Position Center Position 3 2 3 ON 1 2 3 OFF 2 3 ON Double Pole, Double Throw Keyway Momentary Position 2 2 3 OFF 2 3 ON 3 5 4 ON www.honeywell.com/sensing 2 3 5 4 ON Keyway Maintained Position 9 Center Maintained Position Opposite Keyway Maintained Position 3 2 1 3 2 1 3 2 1 6 5 ON 4 6 5 ON 4 6 5 ON 4 MANUAL SWITCHES TP Series Rocker Switches Approvals: Operating temperature: Mounting: Termination: Contacts: Honeywell’s 2 and 3 position, pushbutton action rocker switches are dust and splash-proof sealed. They can be provided with or without buttons. The switches are available as flush or panel mount, a large selection of rocker colors, circuitries and electrical terminations. Versions are available with silver or gold contacts to meet a variety of electrical load requirements. For options other than those shown below, contact Honeywell for more information. UL, CSA, CE -54 °C to 71 °C [-65 °F to 160 °F] Above Panel and Flush Panel Screw Silver cadmium oxide Electrical ratings (Resistive load): Values below are based on previous Honeywell testing and opinion. A 0.5 A to 18 A at 0.5 Vdc to 28 Vdc|0.5 A to 10 A at 0.5 Vac to 277 Vac| 0.75 A at 115 Vdc|0.5 A at 250 Vdc B 0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.75 A at 115 Vdc| 0.5 A at 250 Vdc|0.5 A to 15 A at 0.5 Vac to 277 Vac C 0.5 A to 10 A at 0.5 Vac to 277 Vac|0.75 A at 115 Vdc| 0.5 A at 250 Vdc|0.5 A to 15 A at 0.5 Vdc to 28 Vdc Switching options/Operating action: 2 Position Switches SPST Single Pole, Single Throw Opposite Identification Identification Lug Lug Position Position 1 2 2 3 OFF 2 3 ON Identification Opposite Identification Lug Lug Momentary Position Position 1 2 ON 1 2 OFF SPDT Single Pole, Double Throw Opposite Identification Identification Lug Lug Position Position UL/CSA Rating Code: L191: 15 A-125, 250, 277 Vac; 1/2 Hp-125 Vac; 1 Hp-250, 277 Vac; 5 A-120 Vac “L” 3 1 L192: 10 A-125, 250, 277 Vac; 1/4 Hp-125 Vac; 1/2 Hp-250, 277 Vac; 3 A-125 Vac “L” 1 2 3 ON DPDT Double Pole, Double Throw Opposite Identification Identification Lug Lug Position Position Application Note: Honeywell does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 V and/or 0.5 A. TP switches use silver cadmium oxide contacts, but gold contact options are available. 2 3 ON 4 1 6 If you have specific questions, contact Honeywell. 2 3 1 5 4 ON 6 2 Identification Opposite Identification Lug Lug Momentary Position Position 3 1 5 6 5 4 ON 3 Position Switches SPDT 6 2 3 1 5 4 ON 6 2 3 5 4 ON Single Pole, Double Throw Identification Lug Momentary Position 1 2 3 ON Center Position 1 2 3 OFF DPDT Opposite Identification Lug Momentary Position 1 2 3 ON Double Pole, Double Throw Identification Lug Momentary Position 7 1 6 www.honeywell.com/sensing 2 Center Position 3 1 5 4 ON 6 2 Opposite Identification Lug Momentary Position 3 1 5 4 OFF 6 2 3 5 4 ON 157 MANUAL SWITCHES Above panel mounting Flush panel mounting Panel cutout Terminals Single pole Double pole 2 Position 3 Position Flush Panel Mount Flush Panel Mount BUTTON CIRCUITRY Translucent No No SPST SPST SPDT OPERATING ACTION 2 1 3 ELECTRICAL RATING C B B UL/CSA RATING L192 L191 L191 OPERATING ACTION 5 4 ELECTRICAL RATING A B UL/CSA RATING L192 L191 CAT. LISTING BUTTON CIRCUITRY 1TP1-6 1TP8-2 1TP8-3 Transparent Translucent No Transparent Translucent SPDT SPDT SPDT DPDT DPDT OPERATING ACTION 6 6 6 7 7 ELECTRICAL RATING C C C A A UL/CSA RATING L192 L192 L192 L192 L192 OPERATING ACTION 7 ELECTRICAL RATING A UL/CSA RATING L192 CAT. LISTING 1TP12-7 1TP201-7 1TP8-7 2TP12-7 2TP1-7 Above Panel Mount BUTTON CIRCUITRY Translucent No DPDT DPDT CAT. LISTING 2TP216-8 2TP7-3 Above Panel Mount BUTTON CIRCUITRY Translucent DPDT Button Options Buttons are removable and interchangeable. They measure 22,1 mm x 37,1 mm [0.87 in x 1.46 in]. COLOUR Translucent Transparent White* Yellow* Black* Green* Red* Blue* CAT. LISTING 12PA6 12PA4 12PA5-W 12PA5-Y 12PA5-BK 12PA5-G 12PA5-R 12PA5-BL * Opaque 158 www.honeywell.com/sensing CAT. LISTING 2TP216-7 MANUAL SWITCHES FR Series Sealed Rocker Switches OPTIONS FRN SERIES The FR Series illuminated and non-illluminated full-size sealed rocker switches offer enhanced design flexibility and set new standards for both performance and reliability. The switches are designed to fit industry standard mounting holes of 44,0 mm x 22,0 mm [1.734 in x 0.867 in] and offer a variety of switch and lamp circuit combinations. Approvals: UL, CSA Mechanical life: 250,000 cycles minimum Electrical life: 50,000 cycles (mom.); 100,000 cycles (maint.) Sealing: IP 67 Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F] Termination style: 6,35 mm x 0,81 mm [0.25 in x 0.032 in] quick connect tabs One pole CIRCUITRY (POS. 3, 2, 1) Off, None, On Off, None, On (Mom.) Off (Mom.), None, On On, None, On On (Mom.), None, On On, Off, On On (Mom.), Off, On On (Mom.), Off, On (Mom.) BEZEL/ACTUATOR COLOR Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black CAT. LISTING FRN91-12BB FRN91-16BB FRN91-14BB FRN91-13BB FRN91-18BB FRN91-11BB FRN91-15BB FRN91-17BB BEZEL/ACTUATOR COLOR Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black CAT. LISTING FRN91-22BB FRN91-26BB FRN91-24BB FRN91-23BB FRN91-28BB FRN91-21BB FRN91-25BB FRN91-27BB Two poles CIRCUITRY (POS. 3, 2, 1) Off, None, On Off, None, On (Mom.) Off (Mom.), None, On On, None, On On (Mom.), None, On On, Off, On On (Mom.), Off, On On (Mom.), Off, On (Mom.) www.honeywell.com/sensing 159 MANUAL SWITCHES OPTIONS FRL SERIES Accessories DESCRIPTION Rocker Boot Two poles, Illumination Style C, 12 V CIRCUITRY (POS. 3, 2, 1) Off, None, On On, None, On On, Off, On On (Mom.), Off, On (Mom.) 160 LAMP/LAMP Green/Amber Green/Green Green/Green Green/Green LENS/LENS CAT. LISTING Large white trans./White bar FRL91-22CGA3-BB79 Large white trans./White bar FRL91-23CGG3-BB79 Large white trans./Large white trans. FRL91-21CGG3-BB77 Large white trans./Large white trans. FRL91-27CGG3-BB77 www.honeywell.com/sensing CAT. LISTING FR-01 MANUAL SWITCHES SR Series Sealed Rocker Switches OPTIONS SRN SERIES The SR Series illuminated and non-illluminated full-size sealed rocker switches offer enhanced performance in a flexible package. The switches are available in single or souble pole configurations, have an optional panel seal, and the SRL Series can be illuminated with square or barshaped lenses. Approvals: UL, CSA Mechanical life: 150,000 cycles minimum Electrical life: 50,000 cycles (mom.); 100,000 cycles (maint.) Sealing: Dual switch seal certified to IP66/IP68 Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F] Termination style: Offered in both 8 and 10 terminal base options. AMP and Packard compatible connectors available. One pole CIRCUITRY (POS. 3, 2, 1) Off, None, On Off, None, On (Mom.) Off (Mom.), None, On On, None, On On (Mom.), None, On On, Off, On On (Mom.), Off, On On (Mom.), Off, On (Mom.) BEZEL/ACTUATOR COLOR Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black CAT. LISTING SRN91-12BB SRN91-16BB SRN91-14BB SRN91-13BB SRN91-18BB SRN91-11BB SRN91-15BB SRN91-17BB BEZEL/ACTUATOR COLOR Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black CAT. LISTING SRN91-22BB SRN91-26BB SRN91-24BB SRN91-23BB SRN91-28BB SRN91-21BB SRN91-25BB SRN91-27BB Two poles CIRCUITRY (POS. 3, 2, 1) Off, None, On Off, None, On (Mom.) Off (Mom.), None, On On, None, On On (Mom.), None, On On, Off, On On (Mom.), Off, On On (Mom.), Off, On (Mom.) www.honeywell.com/sensing 161 MANUAL SWITCHES OPTIONS SRL SERIES Accessories DESCRIPTION Connector Housing CAT. LISTING HRSR-01 DESCRIPTION Connector Housing CAT. LISTING SR-01 Two poles, Illumination Style A, 12 V CIRCUITRY (POS. 3, 2, 1) Off, None, On LAMP/LAMP Red/None CAT. LISTING SRL91-22ARN3-BB9N Two poles, Illumination Style U, 12 V CIRCUITRY (POS. 3, 2, 1) On, None, On On, Off, On On (Mom.), Off, On (Mom.) Off, None, On On, None, On On, Off, On Off, None, On 162 LAMP/LAMP Red/Red Red/Red Red/Red Green/Amber Green/Green Green/Green Green/Green LED VOLTAGE 12 V 12 V 12 V 12 V 12 V 12 V 12 V CAT. LISTING SRL91-23URR3-BB99 SRL91-21URR3-BB99 SRL91-27URR3-BB99 SRL91-22UGA3-BB99 SRL91-23UGG3-BB99 SRL91-21UGG3-BB99 SRL91-22UGG3-BB99 www.honeywell.com/sensing MANUAL SWITCHES MR Series Miniature Rocker Switches OPTIONS MR SERIES These miniature rocker switches offer a variety of aesthetic and functional options ranging from circuit configurations to ac and dc ratings. They feature industry standard dimensions, an easy snap-in mounting method, and offer one-or-two pole switches in numerous single-throw and double-throw maintained and momentary circuits. The illuminated and non-illuminated miniature switches are intended to meet the needs of a wide variety of industries and potential applications. The silver-alloy contacts will handle a range of electrical loads. The illuminated products offer LED or neon-style lamps. Approvals: Mechanical life: Electrical life: Dielectric strength UL/CSA: Operating temperature: Termination style: UL, CSA 100,000 cycles minimum 50,000 cycles 1000 V 0 °C to 85 °C [32 °F to 185 °F] 4,75 mm x 0,81 mm tab QC [0.187 in x 0.032 in] tab QC Non-Illuminated POLES 1 2 CIRCUITRY N N CAT. LISTING MR93-12BBN MR93-22BBN Illuminated, Single Pole * Electrical Ratings (UL/CSA) N 8 A, 125 Vac; 12 A, 125 Vac, ½ HP, 125 Vac - 250 Vac; UL, CSA 1 N/A 2 12 A, 6 V 3 12 A, 12 V 4 12 A, 24 V A 12 A, 6 V C 12 A, 12 V E 12 A, 18 V H 12 A, 24 V J 12 A, 125 Vac; UL, CSA K 8 A, 250 Vac; UL, CSA LAMP 12 V LED 12 V LED 125 V Neon 250 V Neon CIRCUITRY* 3 3 J K ACTUATOR COLOR Clear Red Clear Green Clear Red Clear Amber CAT. LISTING MR93-122B3 MR93-124B3 MR93-122BJ MR93-121BK ACTUATOR COLOR Clear Red Clear Green Clear Amber CAT. LISTING MR93-222B3 MR93-224B3 MR93-221B4 Illuminated, Double Pole LAMP 12 V LED 12 V LED 24 V Neon CIRCUITRY* 3 3 4 www.honeywell.com/sensing 163 MANUAL SWITCHES MRS Series Miniature Rocker Switches These subminiature rocker switches offer a variety of aesthetic and functional options ranging from circuit configurations to ac and dc ratings. They feature industry standard dimensions, an easy snap-in mounting method, and offer one-or-two pole switches in numerous single-throw and double-throw maintained and momentary circuits. These non-illuminated switches are often ideal for applications where there is restricted space behind the panel. It fits in a standard rectangular cutout and is designed to fit easily and securely. The snapaction contacts provide the user with a crisp, positive response. A variety of circuitry choices will appeal to many industry segments. Approvals: UL, CSA Mechanical life: 100,000 cycles minimum Electrical life: 50,000 cycles (mom.); 100,000 cycles (maint.) Dielectric strength UL/CSA: 1000 V Operating temperature: 0 °C to 85 °C [32 °F to 185 °F] Termination style: 4,75 mm x 0,81 mm tab QC [0.187 in x 0.032 in] tab QC OPTIONS MRS SERIES One pole CIRCUITRY (POS. 3, 2, 1) Off, None, On Off, None, On (Mom.) Off (Mom.), None, On On, None, On On (Mom.), None, On On, Off, On On (Mom.), Off, On On (Mom.), Off, On (Mom.) BEZEL/ACTUATOR COLOR Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black Black/Black ELEC. RATING* 1 3 3 1 3 2 2 2 CAT. LISTING MRS93-12BB MRS93-16BB MRS93-14BB MRS93-13BB MRS93-18BB MRS93-11BB MRS93-15BB MRS93-17BB * Electrical Ratings (UL/CSA) 164 1 10 A, 125 Vac; 10 A, 250 Vac; ¼ HP, 125 Vac - 250 Vac 2 8 A, 125 Vac - 250 Vac; ¼ HP, 125 Vac - 250 Vac 3 12 A, 125 Vac; 6 A, 250 Vac; ¼ HP, 125 Vac - 250 Vac www.honeywell.com/sensing MANUAL SWITCHES AND PUSHBUTTONS Manual Switches and Pushbuttons Manual Switches. Designed by industrial designers to achieve balance between harmonious appearance and ergonomics, AML Advanced Manual Line has pushbuttons, paddles, and rockers; with LED, incandescent, and neon illumination. Plus, matching indicators and LED annunciators. A smaller cousin, MML Minature Manual Line, offers many AML features in a space-saving size. Pushbuttons. A wide array of different pushbutton families, many with lighted display and matching indicators. Includes Series 2, an easily assembled modular design with many color display/control options; and compact PB unlighted pushbuttons. www.honeywell.com/sensing 165 MANUAL SWITCHES AND PUSHBUTTONS Panel Area 20,5 mm [0.80 in] square and 20,5 mm x 30 mm [0.80 in x 1.20 in] PWB mount: 10,2 mm [0.40 in] square and 15,2 mm x 10,2 mm [0.60 in x 0.40 in], except 2-pole power duty paddles and rockers 21,3 x mm x 26,2 mm [0.84 in x 1.03 in] Display 15,0 mm [0.59 in] square and 15,0 mm x 25,0 mm [0.59 in x 0.99 in] buttons Pushbuttons: 6,6 mm [0.26 in] square and 11,7 mm x 6,6 mm [0.46 in x 0.26 in]. Transmitted color 13,5 mm x 18.0 mm [0.53 in x 0.71 in] buttons Pushbutton or lens cap (indicator only) buttons with up to 3-section display. Various button heights. Transmitted, projected, and dead front hidden legend/color Rockers: Optional lenses for transmitted color Illumination Incandescent T-1-3/4 lamps – 6 V, 14 V, and 28 V LEDs - 2 V, 4 V, 5 V, 10 V, 15 V Neon lamps – 125 V, 250 V LEDs - 1.7 V, 2.1 V, 2.2 V, 2.3 V Incandescent T-1 lamps – 5 V (other voltages available) Incandescent T-3-1/4 lamps 14 V, 28 V Behind Panel Depth (max.) 43,1 mm [1.7 in] 17,0 mm [0.67 in] 6,1 mm [2.4 in] Mounting Snap-in individual, strip, matrix, sub-panel, P.C. board mounting Printed wiring board, snap-in strip, matrix Snap-in individual or strip mounting; top panel or sub-panel mounting Termination Solder, quick-connect, P.C. board, push-on Printed wiring board, solder, quick-connect Solder, quick-connect, P.C. board Sealing Optional panel seal – – Special Features Along with companion rockers and paddles, provides the most advanced and complete line of manual controls available – Can be furnished with locked button feature for use in public areas where tampering is a problem Single section display Transmitted, projected, and dead front hidden color Solid State: 5, 6 - 16, or 4.5 - 24 Vdc Electronic control: Up to 3 A, 125 Vac Power Duty: up to 10 A, 125/250 Vac Solid State: 5 Vdc to 24 Vdc Electronic Control: Up to 1 A, 125 Vac res. Power Duty Pushbuttons: up to 6 A, 250 Vac res. Circuitry Current sinking 1, 2, and 4 Form C 2 pole, Form X Current sinking 1 or 2 Form C 1 or 2 Form X Agency Listings UL, CSA, CDE and CE (selected products)* Electrical Data UL and CSA * For complete international compliance information, contact the 800 number. 166 Series 4 MML AML www.honeywell.com/sensing up to 10 A 1 or 2 Form C UL, CSA MANUAL SWITCHES AND PUSHBUTTONS AML PB Series 2 25,4 mm x 35,8 mm [1.0 in x 1.41 in] 21,8 mm x 34,3 mm [0.86 in x 1.35 in] Depends on type and number of basic switches 20,5 x mm x 30,5 mm [0.80 in x 1.20 in] 21,6 mm x 27,4 mm [0.85 in x 1.08 in] buttons. 8,1 mm [0.32 in] dia., and other button sizes Paddle: Full and split color covers 1-4 section display Transmitted and projected color Colored buttons Incandescent T-1-3/4 lamps, 28 V – – 83,3 mm [3.28 in] – – Snap-in flange mount and units with mounting barriers for individual or strip mount Threaded bushing Snap-in individual, strip, matrix, sub-panel, P.C. board mounting Solder, quick-connect, and screw terminals Solder terminals Solder, quick-connect, P.C. board, push on – Panel seal version. Hermetically sealed units – Compact size 1 A to 20 A, 125 Vac, 250 Vac, 480 Vac, depending on switch module specified 2 A to 5 A, 125/250 Vac Solid state: 5, 6 -16, or 4.5 - 24 Vdc 1 - 4 Form C 1 - 4 Form C Current sinking 1, 2, & 4 Form C, 2 or 3 positions, 2 or 3 positions, mom. or maint. mom. or maint. UL, CSA UL, CSA. Some meet MIL-S-8805 and MIL-STD-1080D www.honeywell.com/sensing Rocker: Full and split color rockers – Matches display/control options of AML pushbuttons Electronic Control: Up to 3 A, 125 Vac Power Duty Pushbuttons: up to 15 A, 125/250 Vac 1 or 2 Form A 2 pos. maint. UL, CSA, VDC, and CE (selected products)* 167 MANUAL SWITCHES AND PUSHBUTTONS AML Series Advanced Manual Line Switches Power-duty switches meet line disconnect application needs with 10-amp pushbuttons and 15-amp paddle and rocker switches. Easy to Wire. All AML devices present single-level termination. This means faster, easier, neater, and more economical wiring. And there is a choice of solder, quick-connect, push-on, and printed circuit termination. Mating Terminals The .110 x .020 quick-connect/solder terminals (types 2 and 8) are designed for use with receptacles that comply with the UL standard for insertion and withdrawal forces. Maximum insertion force is 12 lbs. max., withdrawal force is 14 lbs. These receptacles are supplied by AMP Inc., Berg, Augat, Hollingsworth, MALCO, Zierick, and others. Refer to Thomas Register or the Yellow Pages for the location of your supplier. Features • Complete selection of pushbutton, rocker, and paddle (toggle type) switches accommodates different functions and helps promote operator efficiency. In Front of the Panel Coordinated, attractive appearance. AML features innovations designed by industrial designers aimed at achieving the best balance of human factors and aesthetic appearance. Operator height, bezel size, and the compatability of square and rectangular shapes blend with other components to harmonize your panel. There’s no visual clutter to distract from man/machine communication. This comprehensive line of lighted and unlighted manual controls features: • Solid state, electronic, and power duty control. • Full or split-screen incandescent display switches and indicators provide vivid transmitted color, projected color (for neutral display when unlit), and dead front (hidden color). • Wide-angle visibility LED and line voltage neon display switches and indicators. • Annunciators back lighted by LEDs enable high density message display. • Pushbuttons for high and intermediate frequency functions. • Keylock switches available for controlled access applications. • Rocker and paddle switches, with two or three positions, for less frequent control functions. • All AML terminations at the same shallow depth (43,1 mm [1.7 in]) for convenient wiring or PC board termination. • Plus lighted indicators and annunciators which complement AML’s universal appeal. • Snap-in surface mount or sub-panel (hidden bezel) mount with mounting hardware. Various controls can be matched with their functions to accommodate the most natural and efficient habit pattern relfex. Keylock-operated switches can be used to assure “authorized personnel only” access. • Pad-printed legends with a clear polyurethane overcoat available in a choice of five standard sizes. Display flexibility. AML offers a choice of five legend sizes, four button heights, full or split second display, and illunimation by incandescent lamps, LEDs or neons. Colors are bright and uniform, providing a strong definition and good visibility. (Non-illuminated devices have the same attractive colors.) • UL recognized, CSA certification. Color display options include: • Transmitted color – color can be distinguished whether the lamp is On or Off. • Dead front – display appears black, until illumination causes legend and color to appear. • Projected color – white display is diffused with color when illuminated. Behind the Panel AMLs simple, cost-effective design provides many behind-panel benefits for the designer and installer/user. Simple to install. They snap in from the panel front individually or in vertical or horizontal strips; or in subpanel mounted strips and matrices that can be pre-assembled and pre-wired. Electrical flexibility. Solid state switches with Hall-effect integrated circuits interface directly with microprocessors and other logic-level devices. These ICs were first applied in MICRO SWITCH solid state keyboards. Today, many MICRO SWITCH products incorporate the Halleffect technology to meet a wide range of position sensing and manual control needs. Electronic control switches with gold or silver contacts, and 1, 2, or 4 poles, will handle up to three amps. Including an encoded version which generates different binary coded outputs merely by changing cam-keyed buttons. 168 • Metric design for worldwide acceptance. • Selected listings are certifed by VDE and CE. (For compliance status, contact the 800 number). Honeywell’s AML Advanced Manual Line combines functional flexibility with electrical versatility to provide a broad range of options to choose from. Easy to Relamp. Relamping of T-1-3/4 incandescent AML91 lamps is accomplished from the front of the panel without tools. (AML92 T-1-3/4 LEDs can be added in the same manner. Full Guard Bezel Option. As an alternative to standard height bezels (1,5 mm [0.6 in]), pushbutton switches can be furnished with full-guard bezels extending 5,0 mm [0.19 in] from the mounting surface. In the free position, standard buttons are flush will full-guard bezels. The raised bezel guards against accidental operation by someone leaning against or dropping something on a control console. High Intensity LEDs for Full-face AML Lighted Display AML 92 Series • Full-face illumination for high visitiblity lighted colors. • Advanced illumination technology combines high-intensity LED in standard T-1-3/4 wedge base lamp package. • Easy plug-in installation in AML lighted switches and indicators. • Low operating temperature permits high density, continuous operation with minimal heat build up. AML92 Series LEDs have a quad chip assembled in a T-1-3/4 wedge base lamp package. They provide full-face illumination when used with lighted pushbutton, rocker and paddle switches, or indicators equipped with incandescent lamp sockets. www.honeywell.com/sensing MANUAL SWITCHES AND PUSHBUTTONS AML Series, continued AML10 Series Approvals: Electromechanical Life* Pushbuttons - Momentary Pushbuttons - Alternate Rockers Paddles *95% survival UL (E53576), CSA (LR4442) 1,000,000 25,000 25,000 25,000 AML10 Series Electrical Data Absolute Maximum Rating 4 Electrical Characteristics Output Leakage Current max. (Released) Switching Time Max. Rise Fall 10% to 90% to 90% 10% Supply Voltage (V s ) Voltage Externally Applied to Output Integrated Circuit Function Supply Current (max.) Output Voltage (Operated) Loads to Output 5 Vdc Sinking 1 3.5 mA (released) 6.5 mA (operated no load) +0.4 V (sinking 8 mA) 2.0 µA 1.0 µs (sinking 8 mA) 1.0 µs (sinking 8 mA) -0.5 Vdc to 7.0 Vdc 0 °C to 65 °C [32 °F to 149 °F] -0.5 V min. 15 V max. (off condition) 20 mA (sinking) -40 °C to 65 °C [-40 °F to 149 °F] 6 Vdc to 16 Vdc Sinking 2 6.5 mA @ 6 Vdc, 10.0 mA @ 16 Vdc (plus load current) 3 +0.4 V (sinking 20 mA max.) 2.0 µA 1.5 µs (sinking 20 mA) 0.5 µs (sinking 20 mA) -1.2 Vdc to +20 Vdc 20 Vdc max. in off condition only -0.5 Vdc min. in off or on condition 40 mA -40 °C to 65 °C [-40 °F to 149 °F] 4.5 Vdc to 24 Vdc Sinking 5V 7.0 mA (released) 24 V 9.0 mA (released) 14.0 mA (operated no load) +0.4 V (sinking 10 mA) 10 µA 1.5 µs (sinking 10 mA) 0.5 µs (sinking 10 mA) -30 Vdc to +30 Vdc -0.5 V min. +24 V max. (off condition) 20 mA (sinking) -40 °C to 65 °C [-40 °F to 149 °F] Storage Temperature 1 Over temperature range of 0 °C to 55 °C [32 °F to 131 °F] and supply voltage of 4.5 Vdc to 5.5 Vdc. Over temperature range of 0 °C to 55 °C [32 °F to 131 °F] and supply voltage of 16 Vdc. 3 At 24 °C [75 °F] 4 As with all solid state components, performance can be expected to deteriorate as rating limits are approached; however, they will not be damaged unless the limits are exceeded. 2 Order Guide SERIES NAME AML10 CAT. LISTING Custom www.honeywell.com/sensing 169 MANUAL SWITCHES AND PUSHBUTTONS AML Series, continued AML20 Series AML40 Series Approvals: Approvals: Electromechanical Life* UL (E12252), CSA (LR4442) VDE (0630/10.78*), CE (Rating 1710 No. 4275.5788) Electromechanical Life Pushbuttons - Momentary 25,000 (silver); 100,000 (gold) Pushbuttons - Alternate 25,000 Rockers 25,000 Paddles 25,000 * Exception: Four-pole AMLs are not included in VDE approval. Order Guide SERIES NAME AML40 AML 20 Series Electrical Data Contacts Voltage Current Load Type Silver or gold-plated silver 250 Vac 125 Vac 24 Vdc 2A 3A 2A 75% Power Factor 75% Power Factor Resistive Gold 125 Vac/Vdc 100 mA Resistive Order Guide SERIES NAME AML20 CAT. LISTING Custom AML30 Series Approvals: UL (E12252), CSA (LR4442) VDE (0630/10.78*), CE (Rating 1710 No. 4275.5788) Electromechanical Life Pushbuttons - Momentary 25,000 Pushbuttons - Alternate 25,000 Rockers 25,000 Paddles 25,000 * Exception: Only the two-pole AML33 and AML34 are certified by VDE. AML 30 Series Electrical Data Voltage Current Pushbuttons Current Rockers or Paddles Load Type 125 Vac 10 A 15 A 60% Power Factor 250 Vac 10 A 15 A 60% Power Factor Order Guide SERIES NAME AML30 170 UL (E58932), CSA (LR4442) N/A CAT. LISTING Custom www.honeywell.com/sensing CAT. LISTING Custom MANUAL SWITCHES AND PUSHBUTTONS MML Series Miniature Manual Line Switches Lighted Display Options Pushbuttons and indicators can be full-face illuminated by LEDs or incandescent lamps for high visibility of colors and legends. Inherently rugged, long-life LEDs can help reduce service and maintenance costs. Also, their low drive and in-rush current (30 mA or less) redueces costs of drive circuitry. Rockers can be furnished with colored lenses for illumination by LEDs or incandescent lamps. Control Versatility Solid state pushbutton switches with Hall-effect integrated circuits interface directly with microprocessors and other logic-level devices. Time-proven for billions of cycles, Hall-effect ICs provide the ultimate in reliability. Electronic control push button or rocker switches, with gold or silver contacts, handle up to 1 A; power-duty switches, up to 6 A. MML Enhances Panel Harmony Features • Breadth of line offers complete selection of pushbuttons, rockers, and indicators to accommodate different functions and promote operator efficiency. • Printed wiring board (PWB) or panel-mounted switches, plus multiunit strip mounting, and single-level termination for cost-effective installation. The attractive, clean line design of the total MML offering is coordinated to work in harmony and enhance the visual qualities of your product. MML will help make a good first impression with your customers by blending with other panel components, and also works hard over the long run to maintain operator satisfaction. • Tactile feedback imparts a definite feel of switching action. How to Order • Coordinated appearance enhances panel harmony. To specify MML catalog listings, refer to the order guides. They are based on a modular cataloging system which gives you the flexibility to choose the combination of feature options that best answers the requirements of your application. • Illumination by long-life LEDs and incandescent lamps – for lighted display versatility. • Solid state, electronic control and power-duty switching – for electrical versatility. • Temperature range 18 °C to 65 °C [0 °F to 149 °F]. Design Freedom Rocker switches are available in the MML Miniature Manual Line. They complement AML pushbuttons and indicators, providing you flexibility and design freedom to meet all your miniature manual control requirements. You can choose the actuator option that matches the switch function and natural-habit pattern reflex of the operator. You no longer need to compromise quality, appearance, or human factors considerations because of size constraints. The MML pushbutton and indicator offering has been expanded to include new square forms which are small enough to fit in the tightest places. Mounting Flexibility Printed wiring board (PWB) mounted switches can be arranged in individual panel openings or multi-unit strips, in a common panel cutout. Optional support brackets provide added rigidity for stand-alone PWBmounted devices. Units with bezels and mounting clips can be snap-in mounted from the front panel. Single-level PWB or solder/quick-connect termination throughout makes wiring faster, easier, and more economical. Housing are designed to accommodate washing, before and after wave soldering, to help prevent contamination during printed wiring board installation. www.honeywell.com/sensing 171 MANUAL SWITCHES AND PUSHBUTTONS MML20 Series Electrical Data Electrical Rating (silver contacts) MML10 Series Approvals: Mechanical Lifetime* Pushbuttons – Momentary Pushbuttons – Alternate Rockers Electrical Lifetime** Pushbuttons – Momentary Pushbuttons – Alternate Rockers UL (E53576), CSA (LR4442) 1,000,000 100,000 100,000 1,000,000 100,000 100,000 Standard buttons Up to 1 A, 125 Vac 1-piece plunger/ lens cap buttons black – up to 1 A, 125 Vac All others – up to 0.5 A, 125 Vac Electrical Rating (gold contacts) All button styles Up to 0.25 A, 30 Vdc UL rating - 0.1 A, 30 Vdc Contact arrangement One pole Form C * 95% survival ** Lifetime at full-rated load MML10 Series Electrical Data Order Guide Electrical Characteristics Integrated circuit function 5 Vdc to 24 Vdc sinking Supply current (max) 7 mA (released) 8 mA (operated no load) Output voltage (operated) 0.3 V (sinking 10 mA) Output leakage current max. (released) 5.0 µA SERIES NAME MML20 MML30 Series Switching time (max). Rise 10% to 90% Fall 90% to 10% 15 µs (sinking 10 mA) 0.5 µs (sinking 10 mA) Rated output current 10 mA sinking Approvals: Mechanical Lifetime* Pushbuttons - Momentary Pushbuttons - Alternate Rockers Electrical Lifetime** Pushbuttons - Momentary Pushbuttons - Alternate Rockers Absolute Maximum Ratings Supply Voltage (Vs) -28 Vdc to 28 Vdc Voltage externally applied to output -0.5 V min.; 28 V max. (off condition) Loads to output 20 mA (sinking) Storage temperature -40 °C to 85 °C [-40 °F to 185 °F] Operating temperature -18 °C to 65 °C [0 °F to 149 °F] and supply voltage of 4.5 Vdc to 5.5 Vdc Electrical rating Silver contacts Contact arrangement 25,000 25,000 25,000 6 A @ 125 Vac, 250 Vac, 2 A @ 30 Vdc 1 A @ 125 Vdc “L”, 1/10 hp @ 125 Vac 1 or 2 poles Form X Order Guide UL (E12252), CSA (LR4442) SERIES NAME MML30 CAT. LISTING Custom 250,000 100,000 250,000 25,000 25,000 25,000 MML40 Series Approvals: UL (E58932), CSA (LR4442) Order Guide SERIES NAME MML40 172 100,000 100,000 100,000 MML30 Series Electrical Data MML31 MML20 Series * 95% survival ** Lifetime at full-rated load UL (E12252), CSA (LR4442) * 95% survival ** Lifetime at full-rated load As with solid state components, performance can be expected to deteriorate as rating limits are approached; however, they will not be damaged unless the limits are exceeded. Approvals: Mechanical Lifetime* Pushbuttons - Momentary Pushbuttons - Alternate Rockers Electrical Lifetime** Pushbuttons - Momentary Pushbuttons - Alternate Rockers CAT. LISTING Custom www.honeywell.com/sensing CAT. LISTING Custom CUSTOM SWITCHES AND ASSEMBLIES Custom Switches and Assemblies Honeywell Sensing and Control’s broad product and technology portfolio combined with our industry experience and know-how offers customers a wealth of choice: Harness assemblies • Cable harness assemblies can be added to many of our products, designed to specific customer requirements. • These may incorporate latest specification leadwire systems, screens, connectors and backshells and aimed at providing customers with a fully integrated solutions. • Custom engineered solutions for customerspecific designs and product packaging • Technology selection • Integration and component miniaturisation For more information contact your local Honeywell sales representative. Shown here are some examples of what we can do. Switch assemblies • Honeywell has many years of experience designing custom solutions for customers. • Our environment and hermetically sealed products may, for instance, be incorporated into housings that provide minimum space envelope or specific mounting arrangement. • They may incorporate precision actuating mechanisms and electronic circuitry to interface with customer systems. Rotary switches • Based on Honeywell basic or miniature hermetic switches, rotary switches can be designed to incorporate multiple poles, specific switch on/off sequences and high or low energy switching. • Potential applications include weapons selectors, Re-fuelling probe indicators and flap position indicators. • Customer-specific space envelope and mounting arrangements can be accommodated. Operator interface products • Honeywell has many examples of custom designed operator interfaced products for both hand and foot operation. • These products may incorporate pushbuttons, indicators and electronic interfacing circuitry. • All products are capable of operating in these most severe environments. www.honeywell.com/sensing 173 CUSTOM SWITCHES AND ASSEMBLIES Gear selectors • Based on rotary switches, this family of rugged and reliable gear selectors is used in armoured vehicle applications. • These products can be modified to meet new potential applications such as illuminated or fluorescent gear position indications, number of gear positions, interlocking, high or low energy switching and mounting arrangements. Flap selectors • A range of commercial aircraft flap selectors based on RVDT (Rotary Variable Differential Transducers) or Honeywell basic switches. • These products can be modified to meet new potential application requirements such as flap positions, mounting arrangements, connectors or electrical harnesses. • The example illustrated incorporates four-position flap selection, environmentally sealed fluorescent flap decal and illuminated position indicators and is based on RVDTs. Cargo loading systems • The door sill roller is part of the cargo loading system that serves as a guiding and protecting element during load and unload operations. Incoming cargo is guided into the cargo loading bay to protect the cargo door sill. • The Y-guide is part of the cargo loading system that controls the lateral guidance of cargo during load and unload operations at the cargo entrance area. The unit is designed as a powered, retractable and overrideable guide. • The angle measurement device is part of door actuator symmetry monitoring. This device prevents damage to the main cargo door and the structure of the aircraft by monitoring the asymmetric movement of the two main cargo door actuators. • The example shown is a Y-guide cargo loading system incorporating robust mechanical components and environmentally sealed position sensors. It is used in commercial aircraft applications. 174 www.honeywell.com/sensing VEHICLE CONTROLS CUSTOM CONTROLS Custom Controls Multi-function controls Competition between off-road equipment manufacturers can be fierce. Honeywell can help you distinguish yourself from the competition by working with you in developing your custom controls and switches. We have innovative and flexible design capabilities coupled with costeffective prices. Quick response including design, and “fit-up” prototypes in weeks versus months from your initial request provides the edge you need to shine over your competition. Control interfaces that are functional, rugged and aesthetically pleasing are an important part of the design process. The ability to ergonomically design numerous functions into one product is our strength. Throttle controls Technological and process capabilities • • • Pro/Engineer software Programmable controllers Electronic shifters Mold flow analysis Control and switch capability • • • • • • • • Sliding, toggle and button engagement Environmentally protected Night visibility/lighted components Key switches Directional Speed control Molded terminal arrays Ergonomically sensitive Indicator light panels Potential Applications • • • • • • • • All terrain vehicles (ATVs) Forestry Indicator light strips Agriculture Lawn and garden Snowmobiles Motorcycles Construction Push/Pull switches Material handling Proportional retarders www.honeywell.com/sensing 175 HOUR METERS Hour meters Honeywell has a wide range of hour meters that are used for recording and tracking the total elapsed time that equipment is in use. Long recognised as the industry leader, the Hobbs brand hour meters are designed for use in a wide variety of potential applications and environments. In order to protect investment in expensive equipment, our customers demand a meter that is accurate and dependable. Down time is not an option - customers need to know when it is time to service their equipment. No matter whether the equipment is for production or recreation, manufacturers, operators and service professionals rely on Honeywell for their hour meters needs. 176 www.honeywell.com/sensing HOUR METERS 98000 Series LCD hour meters The 98000 Series LCD hour meter combines reliability with a solid state package, built for rugged, heavy-duty applications. The meter utilizes a large LCD display with 6 mm [0.24 in] high digits. Other benefits include shorter overall meter depth, totally silent operation, non-volatile memory and solid-state circuitry. A wide variety of mounting styles are offered that are direct replacements for most traditional hour meters. Optional offerings include, reset capability, customised logos, 4.5 Vdc to 16 Vdc, and pulse counters. The series is UL recognised and comes in a variety of mounting and case options. Termination: Sealing: Approvals: Operating temperature: Voltage range: 6,35 mm [¼ in] blade IP66 (Cased hour meters only) UL -40 °C to 85 °C [-40 °F to 185 °F] 9 Vdc to 64 Vdc OPTIONS 2 Screw, deluxe bezel Round, 2¼ in [57,15 mm], chrome, flush cup mount 35,80 (1.41) 31,80 (1.25) 22,60 (0.89) 2,00 (0.08) Ø 57,7 (2.27) Ø 50,8 (2.00) 54,10 (2.13) 3,60 (0.14) 19,10 (0.75) 7,60 (0.30) Ø 61,2 (2.41) 34,30 (1.35) 3,00 (0.12) 18,5 (0.73) 2 Screw Deluxe: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening 2 x 3,81 (0.15) holes spaced 44,45 (1.750) 15,2 (0.60) Ø 50,4 (1.985) Flush Mount (Retainer) 57,77 (2.27): Panel cutout 50,8 (2.00) Ø opening NUMBER OF TERMINALS 2 3 4 with reset CAT. LISTING 98313 98323 98303 NUMBER OF TERMINALS 2 3 4 CAT. LISTING 98314 98324 98304 Rectangular, retainer mount Round, 2¼ in [57,15 mm], black, flush cup mount 27,40 (1.08) 40,60 (1.60) Ø 57,7 (2.27) 2,50 (0.10) Ø 50,8 (2.00) 19,10 (0.75) 34,30 (1.35) 7,60 (0.30) Ø 61,2 (2.41) 18,5 (0.73) Retainer Mount: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening NUMBER OF TERMINALS 2 3 4 3,00 (0.12) 15,2 (0.60) CAT. LISTING 98311 98321 98301 Ø 50,4 (1.985) Flush Mount (Retainer) 57,77 (2.27): Panel cutout 50,8 (2.00) Ø opening NUMBER OF TERMINALS 2 3 4 www.honeywell.com/sensing CAT. LISTING 98312 98322 98302 177 HOUR METERS 98000 Series LCD hour meter modules 98000 Series LCD volt/hour meters The LCD hour meter module is a custom engineered elapsed time meter designed to be mounted directly onto a printed circuit board (PCB). It can be used in a variety of dc applications that require an hour meter for preventative maintenance, warranty verification, renting and leasing. LCD counter also available. Honeywell Sensing and Control has introduced the LCD volt/hour meter that combines two important instruments in one rugged, sealed package. Honeywell volt hour meters monitor the condition of battery electrical systems and simultaneously measure the total elapsed run time of equipment in which they are installed. During operation, the micro-controller based movement will cycle the LCD display between voltage and hours indication at a rate of fifteen seconds on for voltage and one second on for total hours. The high-impact polycarbonate case is sealed against dust and moisture. Available in various bezel and mounting configurations, Honeywell’s volt/hour meters are the perfect choice for a variety of applications. Approvals: Voltage range: UL, CSA 9 Vdc to 64 Vdc 4.5 Vdc to 16 Vdc A B Termination: Sealing: Operating temperature: Voltage range: 6,35 mm [¼ in] blade IP66 -40 °C to 85 °C [-40 °F to 185 °F] 7 Vdc to 19 Vdc OPTIONS Combination volt/hour meters 2 Screw, deluxe bezel 15,24 (0.60) 5,08 (0.20) 33,78 (1.33) Mounting surface 26,03 (1.025) 5,90 (0.23) Ø 0,76 ±0,05 (0.03 ±0.002) NUMBER OF TERMINALS 4 4 4 VOLTAGE RANGE A B A 31,80 (1.25) 22,60 (0.89) 14,00 (0.55) 20,57 (0.81) 7,62 (0.30) Metal bezel 35,80 (1.41) 27,94 (1.10) 5,84 (0.23) 2,00 (0.08) 54,10 (2.13) 0,135 (3.43) 3,60 (0.14) 19,10 (0.75) 34,30 (1.35) CAT. LISTING 98706 98707 98750 2 Screw Deluxe: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening 2 x 3,81 (0.15) holes spaced 44,45 (1.750) CAT. LISTING 98103 CAUTION All meter modules have crucial components exposed. The module must be sufficiently protected if used in an environment other than specified. Contact Honeywell when suitability of application is questioned. Rectangular, retainer mount 27,40 (1.08) 40,60 (1.60) 2,50 (0.10) 19,10 (0.75) 34,30 (1.35) Retainer Mount: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening CAT. LISTING 98101 178 www.honeywell.com/sensing HOUR METERS 98000 Series LCD volt/hour meters (continued) Volt meters Combination volt/hour meters Round, 2¼ in [57,15 mm], chrome, flush cup mount Ø 57,7 (2.27) The volt meter incorporates the features and benefits of the LCD volt hour meter but is used for volts only. The large easy to read LCD display provides a digital readout of the vehicle voltage. Available in standard Round, 2-Screw and Rectangular case configurations, volt meters require only battery positive and ground leads for installation and operation. Ø 50,8 (2.00) Termination: Sealing: Operating temperature: Voltage range: 7,60 (0.30) Ø 61,2 (2.41) 18,5 (0.73) 3,00 (0.12) 6,35 mm [¼ in] blade IP66 -40 °C to 85 °C [-40 °F to 185 °F] 7 Vdc to 19 Vdc 2 Screw, deluxe bezel CAT. LISTING 98108 15,2 (0.60) Ø 50,4 (1.985) Flush Mount (Retainer) 57,77 (2.27): Panel cutout 50,8 (2.00) Ø opening Rectangular, retainer mount CAT. LISTING 98111 CAT. LISTING 98106 Round, 2¼ in [57,15 mm], black, flush cup mount Round, 2¼ in [57,15 mm], chrome, flush cup mount Ø 57,7 (2.27) CAT. LISTING 98110 Ø 50,8 (2.00) Round, 2¼ in [57,15 mm], black, flush cup mount 7,60 (0.30) Ø 61,2 (2.41) 18,5 (0.73) 3,00 (0.12) CAT. LISTING 98109 15,2 (0.60) Ø 50,4 (1.985) Flush Mount (Retainer) 57,77 (2.27): Panel cutout 50,8 (2.00) Ø opening CAT. LISTING 98102 Maintenance Meter CAT. LISTING 98202 www.honeywell.com/sensing 179 HOUR METERS 85000 Series Quartz plus dc hour meters The Quartz Plus Series of hour meters are aimed at providing performance and reliability. Features include a highly reliable drive mechanism and odometer gear train combined with the accuracy of quartz crystal timing. The totally sealed meters are UL/CSA recognized and come in a variety of mounting styles. Termination: Sealing: Approvals: Operating temperature: Voltage range: 6,35 mm [¼ in] blade IP67 UL, CSA -40 °C to 85 °C [-40 °F to 185 °F] 10 Vdc to 80 Vdc 6.5 Vdc to 16 Vdc 10 Vdc to 32 Vdc A B C OPTIONS Rectangular, stirrup mount 2 Screw, bezel 44,70 (1.76) 54,10 (2.13) 31,75 (1.25) 32,00 (1.26) 23,88 (0.94) 2,03 (0.08) 2,03 (0.08) 6,10 (0.24) 6,10 (0.24) 36,58 (1.44) 47,50 (1.87) 47,50 (1.87) 73,15 (2.88) 8,38 (0.33) 8,38 (0.33) 2 Screw Mount: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening 2 x 3,81 (0.15) holes spaced 44,45 (1.750) VOLTAGE RANGE A B Rectangular Stirrup: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening VOLTAGE RANGE C CAT. LISTING 85094 85331 CAT. LISTING 85010 Rectangular, retainer mount 3 Screw, round 39,37 (1.55) 26,16 (1.03) Ø 72,64 (2.86) Ø 55,63 (2.19) 2,54 (0.10) Ø 50,42 (1.985) 7,11 (0.28) 3,30 (0.13) 47,50 (1.87) 55,63 (2.19) 48,01 (1.89) 8,38 (0.33) 3 Screw Mount: Panel cutout 50,80 (2.00) Ø opening 3 x 3,81 (0.15) holes equally spaced on a 64,26 (2.53) bolt circle Ø VOLTAGE RANGE A CAT. LISTING 85097 Rectangular Retainer: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening Sealing: VOLTAGE RANGE A 180 www.honeywell.com/sensing IP66 CAT. LISTING 82320 HOUR METERS 85000 Series Quartz plus dc hour meters (continued) Round, 2¼ in [57,15 mm], chrome, flush cup mount 82400 Series Quartz dc hour meters, polarity insensitive Termination: Sealing: Approvals: Operating temperature: Voltage range: Ø 57,66 (2.27) 6,35 mm [¼ in] blade IP66 UL -40 °C to 85 °C [-40 °F to 185 °F] 10 Vdc to 80 Vdc OPTIONS 2 Screw, bezel Ø 50,80 (2.00) 35,8 (1.41) 7,62 (0.30) Ø 61,21 (2.41) 31,80 (1.25) 22,6 (0.89) 3,05 (0.12) 2,00 (0.08) 54,10 (2.13) 3,60 (0.14) 47,75 (1.88) 55,60 (2.19) 8,38 (0.33) Ø 50,42 (1.985) 48,00 (1.89) Flush Mount (Cup): Panel cutout 57,66 (2,27) 50,80 (2.00) Ø opening VOLTAGE RANGE A CAT. LISTING 85342 CAT. LISTING 82416 Round, 2¼ in [57,15 mm], black, flush cup mount Rectangular, retainer mount 39,37 (1.55) Ø 57,66 (2.27) 26,16 (1.03) Ø 50,80 (2.00) 2,54 (0.10) 7,62 (0.30) Ø 61,21 (2.41) 3,05 (0.12) 55,63 (2.19) 48,01 (1.89) 47,75 (1.88) 8,38 (0.33) Rectangular Retainer: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening Ø 50,42 (1.985) Flush Mount (Cup): Panel cutout 57,66 (2,27) 50,80 (2.00) Ø opening VOLTAGE RANGE A CAT. LISTING 82401 CAT. LISTING 85093 www.honeywell.com/sensing 181 HOUR METERS 82400 Series Quartz dc hour meters, polarity insensitive (continued) 20000 Series Deluxe ac hour meters Honeywell’s 20000 Series Deluxe ac meter is a completely sealed hour meter that utilizes a synchronous motor to drive the odometer gear train. Meters are available in a combination of mounting styles, voltages and frequencies and are UL Listed, CSA and CE Certified. Termination: Sealing: Approvals: Operating temperature: Voltage range: Round, 2¼ in [57,15 mm], black, retainer mount A B C D Screw IP65 UL, CSA, CE -54 °C to 68 °C [-65 °F to 154 °F] 120 Vac, 60 Hz 240 Vac, 60 Hz 120 Vac, 50 Hz 240 Vac, 50 Hz OPTIONS Ø 56,90 (2.24) 2 Screw, bezel 35,5 (1.40) Ø 49,78 (1.96) 25,90 22,70 (1.02) (0.89) 52,60 (2.07) 5,33 (0.21) 2,70 (0.11) 2,79 (0.11) 36,6 (1.44) 4,20 (0.165) 50,80 (2.00) 47,50 (1.87) 64,80 (2.55) 7,62 (0.30) 2 Screw Mount: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening 2 x 3,81 (0.15) holes spaced 44,45 (1.750) Ø 50,42 (1.985) CAT. LISTING 82404 VOLTAGE RANGE A B C D CAT. LISTING 20001 20007 20028 20029 3 Screw, round Ø 55,60 (2.19) Ø 68,60 (2.70) 3,30 (0.13) Ø 50,40 (1.985) 7,40 (0.29) 46,50 (1.83) 60,50 (2.38) 3 Screw Mount: Panel cutout 50,8 (2.00) Ø opening 3 x 3,175 (0.125) holes equally spaced on 61,47 (2.42.) circle Ø VOLTAGE RANGE A B C D 182 www.honeywell.com/sensing CAT. LISTING 20017 20019 20016 20018 HOUR METERS 28000 Series Standard ac hour meters The Honeywell 28000 Series ac hour meters use a synchronous motor to drive the odometer gear train. These meters can be used in a wide variety of potential applications including control panels and medical applications. All styles are UL, CSA and CE certified. Termination: Sealing: Approvals: Operating temperature: Voltage range: A B C D 6,35 mm [¼ in] blade IP64 UL, CSA, CE -54 °C to 68 °C [-65 °F to 154 °F] 120 Vac, 60 Hz 240 Vac, 60 Hz 120 Vac, 50 Hz 240 Vac, 50 Hz OPTIONS Rectangular, retainer mount 39,37 (1.55) 26,16 (1.03) 2,54 (0.10) 55,63 (2.19) 48,01 (1.89) Rectangular Retainer: Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening VOLTAGE RANGE A B C D CAT. LISTING 28000 28004 28002 28006 Round, 2¼ in [57,15 mm], retainer mount VOLTAGE RANGE A CAT. LISTING 28030 www.honeywell.com/sensing 183 KEY SWITCHES Key Switches Honeywell Key switches are custom engineered, environmentally sealed, sliding contact switches. They can be designed to match existing keys or to use a six tumbler mechanism with up to 300 unique key combinations. The stainless steel keyhole shroud and keyhole dust shutter contribute to the durability of the assembly while O-rings protect the contact and rotor assembly from moisture and contamination. Key switches can be used in off-highway, material handling or other potential applications where environmental specifications must be met. They have been tested for temperature, vibration, dust, cycling, humidity, pressure wash and salt fog and mount into a 22,10 mm [0.87 in] hole in panels 3,81 mm to 6,35 mm [0.15 in to 0.25 in] thick. Standard configurations are shown below, others are available. Contact your Honeywell sales representative for more information. Mechanical life: Operating temperature: 25000 cycles -40 °C to 85 °C [-40 °F to 185 °F] Screw or Packard MetriPack 280 Series Screw - 20 A, 12 Vdc 10 A, 24 Vdc 4 A, 48 Vdc Packard MetriPack - 20 A, 12 Vac 8 A, 24 Vac Connector: Electrical rating: 2 Position 3 Position 3 Position OFF ON OFF 45˚ 45˚ ON OFF - ON 45˚ 45˚ START OFF OFF - ON - START (Key removable in OFF position) 4 Position ON PREHEAT 45˚ ON ON OFF ON - OFF - ON (Key removable in OFF position) 45˚ 22.5˚ 22.5˚ START OFF - ON - PREHEAT - START (Key removable in OFF position) OPTIONS Integral connector Screw terminals 39,88 1.57 72,39 2.85 43,43 1.71 Ø 41,15 1.62 Ø 41,15 1.62 SWITCH POSITIONS 2 (Off/On) 3 (Off/On/Start) 3 (On/Off/On) 184 74,93 2.95 CAT. LISTING 84828 84829 84830 SWITCH POSITIONS 2 (Off/On) 3 (Off/On/Start) 3 (Off/On/Start, Magneto Ground) 4 (Off/On/Preheat/Start) www.honeywell.com/sensing CAT. LISTING 84825 84826 89165 89477 PUSH/PULL SWITCHES Push/Pull Switches Honeywell’s Push/Pull switches are robust, environmentally sealed, positive action, sliding contact switches incorporating two circuits with multiple combinations. The switch can be designed with a single contact closure in either the push or pull position, two contact closures in either the push or pull positions or a single contact closure in both the push and pull position. For more details on these options, contact a Honeywell sales office. The dual O-ring design protects the contact chamber by isolating it from moisture or any other contaminant. These switches may be suitable for the demands of harsh environments found in off-highway, material handling or other applications where rapid, positive action is required. Mechanical life: Operating temperature: 25000 cycles -40 °C to 100 °C [-40 °F to 212 °F] Screw Terminals 20 A, 12 to 14 Vdc 10 A, 24 Vdc IP67 Connector: Electrical rating: Sealing: Mounting panel thickness 1,27 - 4,83 (0.05 - 0.19) 72,01 (2.835) CIRCUITRY 2NO Circuits in Push 1NO/1NC Circuits in Push 28,32 (1.115) CAT. LISTING 87941 87943 www.honeywell.com/sensing 185 SHIFTERS Honeywell electromechanical shifters are often ideal for meeting the direction and speed control requirements of most off-highway applications. They are completely sealed and are built to withstand the harsh environments of the off-highway industry. Shifters Mounting clamps for shifters and turn signals are available to order separately, with or without locating pin, for column sizes shown in order guides. Standard configurations are shown below, others are available. Contact your Honeywell sales representative for more information. Mechanical life: Rotary Shifter handle Lever 1 million cycles (2 A, 12 V load) 500,000 cycles with drop down neutral lock 3 million cycles without drop down neutral lock 5 million cyles Sealing: IP67 Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F] Supply voltage: 3V to 32 V operation [12 V or 24 V typ.] Mounts to column size: 38 mm, 45 mm or 55 mm [1.50 in, 1.77 in or 2.17 in] Neutral lock: Drop down Connector: Integral Packard, Integral Deutsch or Wire harness 220,47 (8.68) 27,94 (1.10) Shifter - FNR Forward, Neutral, Reverse OPTIONS Column size 38 mm or 45 mm [1.50 in or 1.77 in] Integral Packard connector FEATURES Neutral lock No neutral lock Neutral lock/Wash/wipe CAT. LISTING 80438 81521 86835 MOUNTING left CAT. LISTING 80909 Wire harness connector 198,50 (7.50) FEATURES Neutral lock 59,18 (2.33) Column size 55 mm [2.17 in] Integral Deutsch connector Ø 38,18 (1.503) 75,46 (2.971) 78,79 (3.102) FEATURES Neutral lock/Horn MOUNTING left CAT. LISTING 80910 Ø 44,45 (1.750) 12.5˚ N 6,10 (0.24) 12.5˚ F 65,02 (2.56) Shifter - FNR Forward, Neutral, Reverse with speed selector OPTIONS Twist grip handle with button switch Button switch handle Column size 38 mm or 45 mm [1.50 in or 1.77 in] Integral Deutsch connector FEATURES Neutral lock Neutral lock/button No neutral lock Neutral lock Neutral lock Optional mounting clamps COLUMN SIZE 38 mm [1.50 in] 45 mm [1.77 in] 186 MOUNTING left or right left or right right MOUNTING left left left left right SPEEDS 4 3 3 bump 6 CAT. LISTING 81248 81426 81758 84105 85874 SPEEDS 4 CAT. LISTING 84467 Wire harness connector CAT. LISTING 80260 80262 FEATURES Neutral lock www.honeywell.com/sensing MOUNTING left PROPORTIONAL RETARDERS Proportional Retarders Honeywell’s Proportional Retarder is a shift-lever handle that attaches to the steering column of a vehicle and gives an electronic pulse-widthmodulated output signal that is proportional to the position of the lever. In standard mounting position, output signal has 10 % duty cycle when lever is pulled towards operator to maximum extent. When moved away from operator to its maximum travel, the lever snaps into a detent indicating the output signal now has 90 % duty cycle. The duty cycle between these two positions is a continuously variable function of position. Housed in a sealed unit with a rugged, positive locking connector, the proportional retarder has reverse voltage, short circuit and over voltage protection. Travel: Supply Voltage: 25° maximum angle travel 9 Vdc to 32 Vdc (12 Vdc to 24 Vdc operating system) Base Frequency: 500 Hz, ± 10 % over temperature and input voltage Duty Cycle: 10 % to 90 %, ± 5 % at limits of travel Output Voltage: Pulse-width-modulated, 0 V to 7 V amplitude Wiring and Connection: Receptacle compatible with positive-locking Deutsch DT06-6S connector with 18 AWG (minimum wiring to conform to 1E815) www.honeywell.com/sensing 187 TURN SIGNALS Turn signal Turn Signals Integral Deutsch connector FEATURES COLUMN SIZE MM [IN] 55 [2.17] CAT. LISTING 80877 Turn signal with wiper control Honeywell Turn signal switches are built to complement the Honeywell shifters or can be mounted independently. A variety of potential operations are available such as wiper speeds, head lamp control, button and auto cancel options. Integral Deutsch connector FEATURES Wash Wash COLUMN SIZE MM [IN] 38/45 [1.50/1.77] 55 [2.17] WIPER SPEEDS Hi/Lo 1 CAT. LISTING 80350 80876 These switches can be tailored to meet your design requirements; contact Honeywell for more information. Mechanical life: Turn signal Wiper Washer Head lamp dimmer 50,000 cycles (8 A, 12 V load) 50,000 cycles (2 A, 12 V load) 20,000 cycles (2 A, 12 V load) 20,000 cycles (15 A, 12 V load) Sealing: IP67 Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F] Supply voltage: 3V to 32 V operation (12 V or 24 V typ.) Mounts to column size: 38 mm, 45 mm, 55 mm [1.50 in, 1.77 in, 2.17 in] Connector: Integral Packard, Integral Deutsch or Wire harness 232,16 (9.14) Ø 36,07 (1.42) Turn signal with head lamp control OPTIONS Integral Packard connector FEATURES COLUMN SIZE MM [IN] 45 [1.77] LIGHTS CAT. LISTING Hazard warning 84884 Integral Deutsch connector 230,63 (9.08) FEATURES COLUMN SIZE MM [IN] Horn/side marker 61,98 (2.44) LIGHTS CAT. LISTING 45 [1.77] Head lamp switch/Dimmer 81705 Wire harness connector 50,8 (2.00) FEATURES Ø 38,18 (1.503) COLUMN SIZE MM [IN] 45 [1.77] LIGHTS CAT. LISTING Head lamp switch 79809 12.5˚ 1 8 7 5 6 2 12 11 10 9 3 65,02 (2.56) 4 12.5˚ 78,99 (3.11) 82,80 84,07 (3.26) (3.31) Ø 55,12 (2.17) Turn signal with wiper and head lamp control OPTIONS Integral Deutsch connector FEATURES Plain handle Button switch handle Wash FEATURES 188 WIPER SPEEDS LIGHTS CAT. LISTING 1 Head lamp dimmer/Flash 81601 Wire harness connector Optional mounting clamps COLUMN SIZE 38 mm [1.50 in] 45 mm [1.77 in] COLUMN SIZE MM [IN] 45 [1.77] CAT. LISTING 80260 80262 Wash Wash Wash/Horn/Auto cancel Wash/Horn COLUMN SIZE MM [IN] 45 [1.77] 45 [1.77] 38/45 [1.50/1.77] 45 [1.77] www.honeywell.com/sensing WIPER SPEEDS LIGHTS CAT. LISTING 1 Hi/Lo/Intermittent Hi/Lo/Intermittent Hi/Lo Dimmer/Flash Dimmer Dimmer/Flash Dimmer/Flash 80279 82570 86320 86508 LIGHTING Lighting products Standard Beam Patterns 100' 50' Sealing: Electrical rating (Voltage/Wattage/Current]:A B IP67 12 Vdc/50 W/4 A 24 Vdc/60 W/2.5 A 1000' Honeywell continues the Hobbs tradition of rugged, off-highway work lamps. More than 20 million incandescent and halogen work lamps have been put to use in some of the most rugged working environments imaginable. Because they are designed for potential use in heavy construction and farming equipment, they are also designed to take shock, vibration and other extreme service conditions in their stride. Flood 50 Ft. x 30 Ft. Trap 25 Ft. x 100 Ft. Spot 1000 Ft. Halogen Swivel Mount Lamps Honeywell offers a full line of heavy-duty, halogen, off highway, vehicle lamps to keep equipment moving long after the sun has set. Our halogen lamp housings are constructed of durable, vibration resistant materials. The securing hardware is zinc plated steel with a black dichromate coating. Reflectors are vacuum metalised. The borosiliate glass lenses are highly resistant to cracking, especially when subjected to extreme temperature changes. Mounting: Stud, ½ in [12,7 mm) Ø OPTIONS 4 in x 6 in [101,6 mm x 152,4 mm] 3 in x 5 in [76,2 mm x 127,0 mm] Dimensions in inches (millimetres) 5.89 (149,60) REF 3.09 (78,49) REF 3.15 (80,01) REF 3.77 3.77 REF (95,76) REF Dimensions in inches (millimetres) 3.12 (78,25) REF 3.53 (89,66) REF 6.90 (175,3) REF 4.49 (114,0) REF 1/2-13 NC-2 STUD 2.24 (56,89) REF 3.10 (78,7) REF 1.2-13 NC-2 BEAM PATTERN Wide Flood Trapezoid Spot ELECTRICAL RATING A A A CAT. LISTING 73761 73763 73764 Stud 3.16 (80,26) REF BEAM PATTERN Wide Flood Wide Flood Trapezoid Trapezoid Spot Spot www.honeywell.com/sensing ELECTRICAL RATING A B A B A B CAT. LISTING 71898 72540 71915 72542 71902 72544 189 LIGHTING Replacement Sealed Beams Round Halogen Lamps, PAR 36 Replacement sealed beams are offered in both 3 in x 5 in [76,2 mm x 127,0 mm] and 4 in x 6 in [101,6 mm x 152,4 mm] rectangular size lenses. These are designed with the same rugged construction as the originals and are designed to meet the same demanding standards. These lamps are also designed to withstand tough environmental conditions, such as sudden temperature change, shock and intense vibration. The PAR 36 Halogen work lamp may be well suited to more traditional agricultural equipment applications. They are virtually the same 4.5 in [114,3 mm] diameter lamps that have been factory-installed on popular makes of combines and tractors over the years. 4.5 in [114,3 mm] Ø lamp OPTIONS Dimensions in inches [millimetres] 5.25 (133,35) 4.5 (114,30) 3 in x 5 in [76,2 mm x 127,0 mm] Dimensions in inches (millimetres) 5.25 (133,35) 3.53 (89,66) REF 5.89 (149,61) REF BEAM PATTERN Wide Flood Trapezoid Spot ELECTRICAL RATING A A A CAT. LISTING 72408 72801 73804 BEAM PATTERN Wide flood Trapezoid 4 in x 6 in [101,6 mm x 152,4 mm] Dimensions in inches (millimetres) 4.49 (114.05) REF 6.90 (175,26) REF BEAM PATTERN Wide Flood Wide Flood Trapezoid Trapezoid Spot Spot 190 ELECTRICAL RATING A B A B A B CAT. LISTING 71017 72541 71792 72543 71794 72545 www.honeywell.com/sensing ELECTRICAL RATING A A CAT. LISTING 73468 73469 SEALED SWITCHES LIGHTING Portable Work Lamp HID Xenon High Intensity Discharge Lamps The Portable work lamp is often ideal for situations when temporary lighting is required. It can be used to replace failed equipment lighting, light dark areas, or service equipment. It is also useful for recreational activities. It operates by plugging the connector into a 12 Vdc cigarette lighter. The work lamp is supplied with a 15 foot [4,92 metre] electrical cable and an 80 lb [36,4 kg] magnet in the base. 3 in x 5 in [76,2 mm x 127,0 mm] with handle and switch Honeywell Xenon high intensity discharge lamps are designed to hold up to the extreme demands of the off-highway construction and agricultural markets. HID technology is significantly more efficient than halogen and produces more light with less amperage draw. HID lamps can provide up to three times the light output compared to the average halogen lamp. The technology allows equipment to operate more safely with less load on the electrical system resulting in optimum alternator and battery life. Honeywell’s HID features an electronic bulb/igniter/ballast system for enhanced performance throughout a broad temperature and vibration range. This reduces normal failure modes including filament breakage producing a life expectancy up to six times greater than a typical halogen lamp. Dimensions in inches [millimetres] 6.00 (152,40) Electrical rating: Operating voltage range: Startup amperage: 3.50 (88,90) Stabilised amperage: Startup time: 4.75 (120,65) 12 V [42 W] 9 V to 16 V 15 A @ 9 V, 9 A @ 16 V 15 A @ 9 V, 2.7 A @ 16 V 0.1 to 5 seconds 138,94 (5.47) BEAM PATTERN Wide flood Spot ELECTRICAL RATING A A CAT. LISTING 80413 80510 146,05 (5.75) 24 V [42 W] 10 V to 32 V 8 A @ 14 V, 5 A @ 32 V 3.3 A @ 14 V, 1.4 A @ 32 V 0.1 to 5 seconds 152,50 ± 19,05 (6.00 ± 0.75) to back of housing 5,08 (0.20) strip 138,94 (5.47) 189,23 (7.45) #16 GA. black wire (-) #16 GA. red wire (+) 22,35 (0.88) 57,15 (2.25) 76,96 (3.03) 1/2-13 NC-2 Stud 12 Volt (System requirement of 42 Watts] 35 W D1S source Wide flood Spot CAT. LISTING 84760-50 88217-50 24 Volt (System requirement of 42 Watts] 35 W D1S source Wide flood Trapezoid www.honeywell.com/sensing CAT. LISTING 88735-50 88913-50 191 LIGHTING Honeywell’s marine lamps are completely weatherproof. They are totally sealed against moisture ingress, and the mounting hardware is stainless steel to prevent rust and corrosion. The housing is shock resistant and can withstand up to 6 G vibration. The flood pattern illuminates an area 80° wide by 30° long. Marine Lamps Suitable applications for Honeywell marine lamps include: • Engine compartment lighting • Deck lighting • Emergency lighting • Launching and docking • Spreader lights • Shrimp and fishing boats • Off-shore oil rigs • Ocean vessels • Barges • Dry dock lighting • Freighters, tankers, etc. • Pleasure craft • Anywhere a corrosion resistant lamp is needed 3 in x 5 in lamp with spreader bracket OPTIONS 3 in x 5 in [76,2 mm x 127,0 mm] 4 in x 6 in [101,6 mm x 152,4 mm] Dimensions in inches (millimetres) 3.12 (78,25) REF Dimensions in inches (millimetres) 5.89 (149,60) REF 3.09 (78,49) REF 3.15 (80,01) REF 6.90 (175,3) REF 4.49 (114,0) REF 3.53 (89,66) REF 2.24 (56,89) REF 3.10 (78,7) REF 1/2-13 NC-2 STUD 3.77 3.77 REF (95,76) REF 1.2-13 NC-2 Stud 3.16 (80,26) REF Stud mount lamp Stud mount lamp Dimensions in inches (millimetres) 3.53 (89,66) REF 5.89 (149,61) REF Replacement Sealed Beam BEAM PATTERN MOUNTING Wide Flood Stud ELECTRICAL RATING A LAMP CAT. LISTING 73620 REPLACEMENT SEALED BEAM CAT. LISTING 74041 Flush mount lamp Dimensions in inches (millimetres) 4.49 (114.05) REF 6.90 (175,26) REF Replacement Sealed Beam 192 BEAM PATTERN MOUNTING Wide Wide Wide Wide Spot Spot Spot Spot Flush Stud Flush Stud Flush Stud Flush Stud flood flood flood flood www.honeywell.com/sensing ELECTRICAL RATING A A B B A A B B LAMP CAT. LISTING 72656 71723 72666 72530 72715 72716 72717 72718 REPLACEMENT SEALED BEAM CAT. LISTING 72108 72108 72728 72728 72719 72719 72720 72720 LIGHTING Marine HID Lamps Custom Vehicle Lighting Honeywell’s HID marine lamps are completely weatherproof. They are totally sealed against moisture ingress, and the mounting hardware is stainless steel to prevent rust and corrosion. 138,94 (5.47) 146,05 (5.75) 152,50 ± 19,05 (6.00 ± 0.75) to back of housing 5,08 (0.20) strip 138,94 (5.47) 189,23 (7.45) #16 GA. black wire (-) #16 GA. red wire (+) 22,35 (0.88) 57,15 (2.25) 76,96 (3.03) Lighting products designed to the form, fit and functional requirements of OEM vehicles is the fastest growing segment in lighting. Continual investment in the latest equipment and software allows optical designs to be created in unique shapes and sizes to meet this need. Honeywell Product Management and Engineering personnel can offer a complete custom design based upon the goals provided. Our manufacturing facilities are equipped to produce such lights in a matter of weeks. This quick turn around for prototype and production components is aimed at meeting even the most aggressive project timetables. 1/2-13 NC-2 Stud 12 Volt (System requirement of 42 Watts] 35 W D1S source BEAM PATTERN Wide flood Trapezoid Spot CAT. LISTING 88432 89444 89445 24 Volt (System requirement of 42 Watts] 35 W D1S source BEAM PATTERN Wide flood Trapezoid Spot CAT. LISTING 89446 89447 89448 www.honeywell.com/sensing 193 OTHER VEHICLE CONTROLS Other Vehicle Controls Honeywell Sensing and Control’s broad product and technology portfolio combined with industry experience and application know-how offers customers a wealth of choice: • Custom engineered solutions for applicationspecific designs and product packaging Pressure switches • • Extensive portfolio of existing designs • • Custom designs possible • Modular designs Designed for transportation-related applications (12 Vdc) Potential applications include engine oil pressure, compressor air pressure, heavy truck air brake pressure, transmission fluid pressure • Proven technology • Low cost • Automotive grade • Extensive portfolio of designs • Extensive high-volume experience Circuit breakers • • • • • • Extensive portfolio of existing designs • 5 A to 50 A Designed for 12 Vdc applications Type 1 automatic reset Type 2 remote reset Type 3 manual reset Multiple designs, terminal styles, and mounting brackets Mechanical switches • • • • 194 Extensive portfolio of existing designs Designed for 12 Vdc applications Multiple designs and terminal styles Potential applications include neutral start, reverse lamp, and 4WD transfer case mode indication www.honeywell.com/sensing PRECISION AEROSPACE Precision Aerospace If you have ever traveled by air, chances are you’ve flown with equipment by Honeywell Sensing and Control. We have been meeting demanding aerospace applications since 1952 under these brand names: Flight control actuation • Linear and rotary flight control actuators with integral position feedback, clutches, brakes, dual motors and other options. • These linear actuators are typically used for helicopter blade control. Many small aircraft use our rotary actuators in their autopilot systems. • Courter • Bendix • Eclipse-Pioneer • Sperry Flight control position sensing • Our linear and rotary position transmitters solve challenging measurement problems in harsh environments. • Added value through features such as integral gear-train and discreet switches, non-linear response, viewing window, auto-rig-lock feature. • MICRO SWITCH • Valetin Cockpit controls • Force and torque sensors integrated into flight control linkage measure pilot input forces. • Speedbrake, flap selector, and other pilot input devices incorporating built-in detents, servo backdrive, and up to quad-channel redundant output. Cockpit indicators • Analog cockpit indicators serve potential applications such as angle of attack, fuel quantity, fuel flow. • Dial, pointer and range markings can be designed to meet almost any customer requirement. • Instruments can be either wedge lighted, backlit, unlighted, or night vision compliant. Pressure switches and transmitters • Pressure switches for a variety of potential applications including engine, hydraulics, and bleedair. Available in a wide operating range with preset dead-band. • Our extremely rugged electromechanical pressure transmitters operate at 250 °C [482 °F] and pressures as high as 11,000 psi and feature ac output. www.honeywell.com/sensing 195 PRODUCT OVERVIEW HONEYWELL SENSING AND CONTROL PRODUCTS Selecting the right sensor or switch for your application has never been easier. Honeywell Sensing and Control has one of the broadest product ranges of any supplier in the world, and the depth of our technology and product lines ensure you are able to find the right product for most applications. We also have the outstanding technical support staff and responsive service to back this up, so you can always find what you need, when you need it. We aim to supply on time, every time, anywhere in the world. Honeywell - Taking the risk and high costs out of system critical sensing and control. You can find out more about Honeywell’s extensive product range by visiting our website at www.honeywell.com/sensing There you can browse our interactive catalogue and discover our full range of products for use in Industrial, Automotive, Aviation, Transportation, Motion Control, Medical applications and more. Some of our more popular product families include: Accelerometers Utilizing Quartz Flexure and Resonating Beam technologies for inertial, control, and industrial applications. Automotive Sensors Speed and position sensors for engine management, wheel speed sensors, and position sensors for comfort, convenience, and motor control applications. Basic Switches Standard size, miniature, subminiature, hermetically sealed, and high temperature snap-action switches for applications requiring compactness, light weight, accurate repeatability and long life. Current Sensors Adjustable linear, null balance, digital, and linear output current sensors for monitoring ac or dc current. Electronic and Electromechanical Safety products for Machine Safeguarding Safety light curtains, laser scanners, mats, door interrupt devices and single and multi-beam optoelectronic devices for industrial machine safety. Safety interlock switches, limit switches and cable-pull limit switches for industrial machine safety. Safety control modules for industrial machine safety. Environment Sealed Switches and Sensors Designed for use in the harsh environments encountered in aerospace, transportation, ordnance and marine applications. The meter family includes LCD, Counter, Battery Controller, AC ElectroMechanical and DC Electro-Mechanical. Humidity Sensors Relative humidity/temperature and relative humidity sensors in chemically resistant packages to accommodate harsh environments. Infrared Sensors Optoelectronic standard infrared emitting diodes (IREDs), sensors and assemblies for object presence, limit, and motion sensing, position encoding, and movement counting. Limit and Enclosed Switches Heavy duty limit switches, enclosed switches (precision snap-acting switches sealed in rugged metal housing) and sealed and explosion-proof switches. Liquid Level Sensors Basic and industrial (designed for harsh industrial environments) liquid level sensors used to indicate the presence or absence of liquid. Mass Airflow Sensors Amplified and unamplified microbridge mass airflow sensors provide a sensitive and fast response to the flow of air or other gas over the chip. Off-Highway Vehicular Lighting Honeywell’s Hobbs brand halogen sealed beams, composites, custom designer lights, specialty lighting and indicator modules for vehicular and non-vehicular applications. Position Sensors Fibre Optic Sensors Active optoelectronic components and sub-assemblies (LEDs/transmitters, fiber-DIPs, receivers and modules) for the datacom market. Hall-effect, magnetoresistive, and potentiometric devices for detecting the presence of a magnetic field or linear and rotary position. Force Sensors Enhanced reliability and performance in compact commercial grade packaging. Hour Meters Honeywell’s Hobbs brand products are designed for elapsed time measurement for testing, leasing, maintenance and warranty programs. 196 www.honeywell.com/sensing PRODUCT OVERVIEW Pressure Sensors Thermal Products A wide offering of media-isolated pressure sensors with multiple pressure ports and electrical signals for a variety of potential applications including the monitoring and control of corrosive media in aggressive environments. Bimetal thermostats, Discrete and Packaged Thermistors, Precision Hi-Rel Negative Temperature Coefficient (NTC) Thermistors, Thermal cut offs and Flexible Heaters Proximity Sensors Megopak thermocouples, thermocouples with protecting tubes, Radiamatic/Rayotube Sensors, and the platinum RTD 100 Ohm. Severe environment proximity sensors designed for use in applications with particularly demanding requirements on temperature, vibration, shock, and EMI/lightning resistance. Pushbuttons, Keyswitches and Indicators MICRO SWITCH brand pushbuttons, keyswitches, and indicators for use anywhere manual operation is desired. Railway Sensors and Control Systems Railwheel proximity sensors, interface modules, train departure control systems, solid state sensors, pressure sensors and electromechanical switches for potential on-board and off-board rail industry applications. Relays General-purpose power relays and relay sockets designed for a wide range of applications that require stability and reliability. Resolvers Absolute position sensors which provides high angular accuracy, high resolution and repeatability under severe environmental conditions. Temperature Sensors Platinum- and silicon-based thin film resistance temperature devices (RTDs) for applications that require small package size, accuracy, and linear outputs. Thermocouples, Non-contact probes and RTDs Toggle and Rocker Switches MICRO SWITCH brand toggles, rockers and paddle switches for use anywhere manual operation is desired. Military grade and environment sealed options are available. Turbidity Sensors Wash process turbidity sensors to improve product quality, minimize ingredient consumption, and reduce wastewater discharge in commercial and industrial bath applications. Ultrasonic Sensors Ultrasonic position sensors for presence/absence sensing, precision distance sensing or tracking for areas where other sensing technologies have difficulty, such as clear or shiny objects, foggy or particle laden air, or splashing liquids. VRS Speed and Timing Sensors Completely self-powered, VRS (magnetic) sensors are simple, rugged devices that do not require an external voltage source for operation. They are generally used to provide speed, timing or synchronization data to a display (or control circuitry) in the form of a pulse train. This list of our products is not exhaustive, so check out our full range at www.honeywell.com/sensing www.honeywell.com/sensing 197 NEW TECHNOLOGIES New Technologies and Emerging Capabilities Honeywell Sensing and Control is constantly developing new technologies to keep customers competitive and at the forefront of their businesses. We excel at delivering innovative sensing and switching solutions with best use of technology. We are able to combine our different sensing technologies to offer differentiating solutions with enhanced precision and accuracy for the increasingly complex needs of our customers. Our range of technologies, combined with our application expertise and our customization capability, is what makes our sensors and switches leaders in their fields. Wireless Pressure and Torque Sensors New sensing capabilities using Surface Acoustic Wave (SAW) technology Potential Applications • Electronic power steering • Electro-hydraulic power steering • Active suspension control • Limited slip drive train controls • Transmissions Emissions sensors New sensing technologies to measure Exhaust gas recirculation (EGR) mass flow, In- cylinder pressure, oxygen, particulate matter, ammonia, nitrogen oxide. 198 www.honeywell.com/sensing INDEX Index 101HS1 . . . . . . . . . . . . . . . . . . . . . . 101TL1-21 . . . . . . . . . . . . . . . . . . . . 102HS1 . . . . . . . . . . . . . . . . . . . . . . 102TL2-2 . . . . . . . . . . . . . . . . . . . . . 102TL2-3 . . . . . . . . . . . . . . . . . . . . . 109HM1 . . . . . . . . . . . . . . . . . . . . . . 111SM1 . . . . . . . . . . . . . . . . . . . . . . 111SM2-T . . . . . . . . . . . . . . . . . . . . 114HM1-2 . . . . . . . . . . . . . . . . . . . . 1172CX12 . . . . . . . . . . . . . . . . . . . . . 1172CX2 . . . . . . . . . . . . . . . . . . . . . . 11CX12 . . . . . . . . . . . . . . . . . . . . . . . 11CX12E . . . . . . . . . . . . . . . . . . . . . . 11CX2 . . . . . . . . . . . . . . . . . . . . . . . . 11CX2E . . . . . . . . . . . . . . . . . . . . . . . 11HM1 . . . . . . . . . . . . . . . . . . . . . . . 11NT1-2 . . . . . . . . . . . . . . . . . . . . . 11NT1-3 . . . . . . . . . . . . . . . . . . . . . 11NT1-7 . . . . . . . . . . . . . . . . . . . . . 11NT1-7-NH . . . . . . . . . . . . . . . . . . 11SM1 . . . . . . . . . . . . . . . . . . . . . . . 11SM601-H4 . . . . . . . . . . . . . . . . . . 11SX1-T . . . . . . . . . . . . . . . . . . . . . 11TS115-3 . . . . . . . . . . . . . . . . . . . 11TS15-1 . . . . . . . . . . . . . . . . . . . . 11TS15-2 . . . . . . . . . . . . . . . . . . . . 11TS15-6 . . . . . . . . . . . . . . . . . . . . 11TS15-7 . . . . . . . . . . . . . . . . . . . . 11TS95-2 . . . . . . . . . . . . . . . . . . . . 11TS95-7 . . . . . . . . . . . . . . . . . . . . 11TW1-1L . . . . . . . . . . . . . . . . . . . . 11TW1-2 . . . . . . . . . . . . . . . . . . . . . 11TW1-3 . . . . . . . . . . . . . . . . . . . . . 11TW1-3D . . . . . . . . . . . . . . . . . . . . 11TW1-7 . . . . . . . . . . . . . . . . . . . . . 11TW8-2 . . . . . . . . . . . . . . . . . . . . . 11TW8-3 . . . . . . . . . . . . . . . . . . . . . 11TW8-5 . . . . . . . . . . . . . . . . . . . . . 11TW8-7 . . . . . . . . . . . . . . . . . . . . . 120000 . . . . . . . . . . . . . . . . . . . . . . 120001 . . . . . . . . . . . . . . . . . . . . . . 120002 . . . . . . . . . . . . . . . . . . . . . . 120003 . . . . . . . . . . . . . . . . . . . . . . 120004 . . . . . . . . . . . . . . . . . . . . . . 120005 . . . . . . . . . . . . . . . . . . . . . . 120006 . . . . . . . . . . . . . . . . . . . . . . 120007 . . . . . . . . . . . . . . . . . . . . . . 120008 . . . . . . . . . . . . . . . . . . . . . . 12HR1-S . . . . . . . . . . . . . . . . . . . . . 12HR8-6 . . . . . . . . . . . . . . . . . . . . . 12NT1-3 . . . . . . . . . . . . . . . . . . . . . 12PA4 . . . . . . . . . . . . . . . . . . . . . . . 129 142 129 141 141 127 106 106 126 65 65 65 65 65 65 127 151 151 152 152 106 106 106 156 156 156 156 156 156 156 144 144 144 144 144 144 144 144 144 116 116 116 116 116 116 116 116 116 138 138 151 158 12PA5-BK . . . . . . . . . . . . . . . . . . . . 12PA5-BL . . . . . . . . . . . . . . . . . . . . 12PA5-G . . . . . . . . . . . . . . . . . . . . . 12PA5-R . . . . . . . . . . . . . . . . . . . . . 12PA5-W . . . . . . . . . . . . . . . . . . . . . 12PA5-Y . . . . . . . . . . . . . . . . . . . . . 12PA6 . . . . . . . . . . . . . . . . . . . . . . . 12SE4-T . . . . . . . . . . . . . . . . . . . . . 12TL1-2 . . . . . . . . . . . . . . . . . . . . . . 12TL1-3 . . . . . . . . . . . . . . . . . . . . . . 12TS115-3 . . . . . . . . . . . . . . . . . . . 12TS15-2 . . . . . . . . . . . . . . . . . . . . 12TS15-3 . . . . . . . . . . . . . . . . . . . . 12TS15-7 . . . . . . . . . . . . . . . . . . . . 12TS95-10 . . . . . . . . . . . . . . . . . . . 12TS95-3 . . . . . . . . . . . . . . . . . . . . 12TW1-1 . . . . . . . . . . . . . . . . . . . . . 12TW1-3 . . . . . . . . . . . . . . . . . . . . . 12TW1-3D . . . . . . . . . . . . . . . . . . . . 12TW1-50 . . . . . . . . . . . . . . . . . . . . 12TW1-50M . . . . . . . . . . . . . . . . . . 12TW1-7 . . . . . . . . . . . . . . . . . . . . . 12TW1-70 . . . . . . . . . . . . . . . . . . . . 12TW29-1 . . . . . . . . . . . . . . . . . . . . 12TW29-7 . . . . . . . . . . . . . . . . . . . . 12TW75-3 . . . . . . . . . . . . . . . . . . . . 12TW75-7 . . . . . . . . . . . . . . . . . . . . 12TW8-3 . . . . . . . . . . . . . . . . . . . . . 12TW8-7 . . . . . . . . . . . . . . . . . . . . . 13HM1 . . . . . . . . . . . . . . . . . . . . . . . 14CE1-1 . . . . . . . . . . . . . . . . . . . . . . 14CE1-1A . . . . . . . . . . . . . . . . . . . . . 14CE1-1G . . . . . . . . . . . . . . . . . . . . . 14CE1-2 . . . . . . . . . . . . . . . . . . . . . . 14CE1-3 . . . . . . . . . . . . . . . . . . . . . . 14CE1-3A . . . . . . . . . . . . . . . . . . . . . 14CE1-3G . . . . . . . . . . . . . . . . . . . . . 14CE1-AQ . . . . . . . . . . . . . . . . . . . . . 14CE1-Q . . . . . . . . . . . . . . . . . . . . . . 14CE101-1 . . . . . . . . . . . . . . . . . . . . 14CE101-10 . . . . . . . . . . . . . . . . . . . 14CE101-2 . . . . . . . . . . . . . . . . . . . . 14CE101-3 . . . . . . . . . . . . . . . . . . . . 14CE101-4 . . . . . . . . . . . . . . . . . . . . 14CE101-5 . . . . . . . . . . . . . . . . . . . . 14CE101-6 . . . . . . . . . . . . . . . . . . . . 14CE102-1 . . . . . . . . . . . . . . . . . . . . 14CE102-12 . . . . . . . . . . . . . . . . . . . 14CE102-15 . . . . . . . . . . . . . . . . . . . 14CE102-3 . . . . . . . . . . . . . . . . . . . . 14CE102-3G . . . . . . . . . . . . . . . . . . . 14CE102-5 . . . . . . . . . . . . . . . . . . . . 14CE102-6 . . . . . . . . . . . . . . . . . . . . 14CE102-6G . . . . . . . . . . . . . . . . . . . 14CE102-8 . . . . . . . . . . . . . . . . . . . . 14CE103-1 . . . . . . . . . . . . . . . . . . . . 158 158 158 158 158 158 158 122 141 141 156 156 156 156 156 156 144 144 144 144 144 144 144 144 144 144 144 144 144 127 24 24 24 24 24 24 24 24 24 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 www.honeywell.com/sensing 14CE103-3 . . . . . . . . . . . . . . . . . . . . 14CE118-1 . . . . . . . . . . . . . . . . . . . . 14CE118-10 . . . . . . . . . . . . . . . . . . . 14CE118-6 . . . . . . . . . . . . . . . . . . . . 14CE16-1 . . . . . . . . . . . . . . . . . . . . . 14CE16-2 . . . . . . . . . . . . . . . . . . . . . 14CE16-3 . . . . . . . . . . . . . . . . . . . . . 14CE18-1 . . . . . . . . . . . . . . . . . . . . . 14CE18-3 . . . . . . . . . . . . . . . . . . . . . 14CE18-Q . . . . . . . . . . . . . . . . . . . . . 14CE2-1 . . . . . . . . . . . . . . . . . . . . . . 14CE2-1A . . . . . . . . . . . . . . . . . . . . . 14CE2-1G . . . . . . . . . . . . . . . . . . . . . 14CE2-2 . . . . . . . . . . . . . . . . . . . . . . 14CE2-2A . . . . . . . . . . . . . . . . . . . . . 14CE2-3 . . . . . . . . . . . . . . . . . . . . . . 14CE2-3A . . . . . . . . . . . . . . . . . . . . . 14CE2-3G . . . . . . . . . . . . . . . . . . . . . 14CE2-AQ . . . . . . . . . . . . . . . . . . . . . 14CE2-Q . . . . . . . . . . . . . . . . . . . . . . 14CE20-1 . . . . . . . . . . . . . . . . . . . . . 14CE20-3 . . . . . . . . . . . . . . . . . . . . . 14CE3-1 . . . . . . . . . . . . . . . . . . . . . . 14CE3-2 . . . . . . . . . . . . . . . . . . . . . . 14CE3-3 . . . . . . . . . . . . . . . . . . . . . . 14CE31-1 . . . . . . . . . . . . . . . . . . . . . 14CE31-3 . . . . . . . . . . . . . . . . . . . . . 14CE66-1 . . . . . . . . . . . . . . . . . . . . . 14CE66-2 . . . . . . . . . . . . . . . . . . . . . 14NT1-3 . . . . . . . . . . . . . . . . . . . . . 14XE1 . . . . . . . . . . . . . . . . . . . . . . . 14XE1-T . . . . . . . . . . . . . . . . . . . . . 15HM2 . . . . . . . . . . . . . . . . . . . . . . . 15HM5 . . . . . . . . . . . . . . . . . . . . . . . 16CX12 . . . . . . . . . . . . . . . . . . . . . . . 16CX2 . . . . . . . . . . . . . . . . . . . . . . . . 18CX0 . . . . . . . . . . . . . . . . . . . . . . . . 18CX10 . . . . . . . . . . . . . . . . . . . . . . . 18CX10E . . . . . . . . . . . . . . . . . . . . . . 19HM1 . . . . . . . . . . . . . . . . . . . . . . . 19HM4 . . . . . . . . . . . . . . . . . . . . . . . 19PA137-HM . . . . . . . . . . . . . . . . . . 1CPSA1 . . . . . . . . . . . . . . . . . . . . . . 1CPSA1A . . . . . . . . . . . . . . . . . . . . 1CPSA1B . . . . . . . . . . . . . . . . . . . . 1CPSA2 . . . . . . . . . . . . . . . . . . . . . . 1CPSA2A . . . . . . . . . . . . . . . . . . . . 1CPSA2B . . . . . . . . . . . . . . . . . . . . 1CPSA3 . . . . . . . . . . . . . . . . . . . . . . 1CPSA3A . . . . . . . . . . . . . . . . . . . . 1CPSA3B . . . . . . . . . . . . . . . . . . . . 1CPSA4 . . . . . . . . . . . . . . . . . . . . . . 1CPSA5 . . . . . . . . . . . . . . . . . . . . . . 1CPSA6 . . . . . . . . . . . . . . . . . . . . . . 1CPSA6A . . . . . . . . . . . . . . . . . . . . 1CPSA6B . . . . . . . . . . . . . . . . . . . . 58 58 58 58 25 25 25 24 24 24 24 24 24 24 24 24 24 24 24 24 25 25 25 25 25 24 24 24 24 151 124 124 127 127 65 65 65 65 65 127 127 127 100 100 100 100 100 100 100 100 100 100 100 100 100 100 199 INDEX 1CPSA7 . . . . . . . . . . . . . . . . . . . . . . 1CPSA8 . . . . . . . . . . . . . . . . . . . . . . 1CPSC1 . . . . . . . . . . . . . . . . . . . . . . 1CPSC1A . . . . . . . . . . . . . . . . . . . . 1CPSC2 . . . . . . . . . . . . . . . . . . . . . . 1CPSC2A . . . . . . . . . . . . . . . . . . . . 1CPSC2B . . . . . . . . . . . . . . . . . . . . 1CPSC3 . . . . . . . . . . . . . . . . . . . . . . 1CPSC3A . . . . . . . . . . . . . . . . . . . . 1CPSC4 . . . . . . . . . . . . . . . . . . . . . . 1CPSC5 . . . . . . . . . . . . . . . . . . . . . . 1CPSC6 . . . . . . . . . . . . . . . . . . . . . . 1CPSC6A . . . . . . . . . . . . . . . . . . . . 1CPSC7 . . . . . . . . . . . . . . . . . . . . . . 1CPSC8 . . . . . . . . . . . . . . . . . . . . . . 1EN1-6 . . . . . . . . . . . . . . . . . . . . . . 1EN231-6 . . . . . . . . . . . . . . . . . . . . 1EN51-6 . . . . . . . . . . . . . . . . . . . . . 1EN61-6 . . . . . . . . . . . . . . . . . . . . . 1EN75-R . . . . . . . . . . . . . . . . . . . . . 1EN75-R3 . . . . . . . . . . . . . . . . . . . . 1EN76-R . . . . . . . . . . . . . . . . . . . . . 1EX1 . . . . . . . . . . . . . . . . . . . . . . . . . 1HE1-6 . . . . . . . . . . . . . . . . . . . . . . 1HE222-6 . . . . . . . . . . . . . . . . . . . . 1HS1 . . . . . . . . . . . . . . . . . . . . . . . . 1HS3 . . . . . . . . . . . . . . . . . . . . . . . . 1HS41 . . . . . . . . . . . . . . . . . . . . . . . 1HS6 . . . . . . . . . . . . . . . . . . . . . . . . 1HT1 . . . . . . . . . . . . . . . . . . . . . . . . 1LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 1LS1-4C . . . . . . . . . . . . . . . . . . . . . . 1LS1-L . . . . . . . . . . . . . . . . . . . . . . . 1LS10 . . . . . . . . . . . . . . . . . . . . . . . . 1LS10-4C . . . . . . . . . . . . . . . . . . . . . 1LS10-L . . . . . . . . . . . . . . . . . . . . . . 1LS131 . . . . . . . . . . . . . . . . . . . . . . . 1LS19 . . . . . . . . . . . . . . . . . . . . . . . . 1LS19-4C . . . . . . . . . . . . . . . . . . . . . 1LS2 . . . . . . . . . . . . . . . . . . . . . . . . . 1LS2-4C . . . . . . . . . . . . . . . . . . . . . . 1LS2-L . . . . . . . . . . . . . . . . . . . . . . . 1LS23 . . . . . . . . . . . . . . . . . . . . . . . . 1LS243 . . . . . . . . . . . . . . . . . . . . . . . 1LS243-4C . . . . . . . . . . . . . . . . . . . . 1LS3 . . . . . . . . . . . . . . . . . . . . . . . . . 1LS3-4C . . . . . . . . . . . . . . . . . . . . . . 1LS3-L . . . . . . . . . . . . . . . . . . . . . . . 1LS47 . . . . . . . . . . . . . . . . . . . . . . . . 1LS501 . . . . . . . . . . . . . . . . . . . . . . . 1LS53 . . . . . . . . . . . . . . . . . . . . . . . . 1LS56 . . . . . . . . . . . . . . . . . . . . . . . . 1LS58 . . . . . . . . . . . . . . . . . . . . . . . . 1LS59 . . . . . . . . . . . . . . . . . . . . . . . . 1LS6 . . . . . . . . . . . . . . . . . . . . . . . . . 1LS9 . . . . . . . . . . . . . . . . . . . . . . . . . 200 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 133 133 133 133 134 134 134 61 137 137 129 128 129 129 130 30 30 30 31 31 31 30 30 30 31 31 31 31 30 30 30 30 30 31 30 31 31 30 30 30 31 1NT1-1 . . . . . . . . . . . . . . . . . . . . . . 1NT1-2 . . . . . . . . . . . . . . . . . . . . . . 1NT1-2G . . . . . . . . . . . . . . . . . . . . . 1NT1-3 . . . . . . . . . . . . . . . . . . . . . . 1NT1-3-NH . . . . . . . . . . . . . . . . . . . 1NT1-3D . . . . . . . . . . . . . . . . . . . . . 1NT1-5 . . . . . . . . . . . . . . . . . . . . . . 1NT1-6 . . . . . . . . . . . . . . . . . . . . . . 1NT1-7 . . . . . . . . . . . . . . . . . . . . . . 1NT1-7-NH . . . . . . . . . . . . . . . . . . . 1NT1-7E . . . . . . . . . . . . . . . . . . . . . 1NT1-8 . . . . . . . . . . . . . . . . . . . . . . 1NT1-8-NH . . . . . . . . . . . . . . . . . . . 1NT20-7E . . . . . . . . . . . . . . . . . . . . 1NT231-7 . . . . . . . . . . . . . . . . . . . . 1NT91-2 . . . . . . . . . . . . . . . . . . . . . 1NT91-7 . . . . . . . . . . . . . . . . . . . . . 1SE1 . . . . . . . . . . . . . . . . . . . . . . . . 1SE1-T . . . . . . . . . . . . . . . . . . . . . . 1SE2 . . . . . . . . . . . . . . . . . . . . . . . . 1SE3 . . . . . . . . . . . . . . . . . . . . . . . . 1SE61-T . . . . . . . . . . . . . . . . . . . . . 1SE7 . . . . . . . . . . . . . . . . . . . . . . . . 1SX1-T . . . . . . . . . . . . . . . . . . . . . . 1TB1-2 . . . . . . . . . . . . . . . . . . . . . . 1TL1-1 . . . . . . . . . . . . . . . . . . . . . . . 1TL1-1A . . . . . . . . . . . . . . . . . . . . . 1TL1-2 . . . . . . . . . . . . . . . . . . . . . . . 1TL1-21 . . . . . . . . . . . . . . . . . . . . . . 1TL1-2D . . . . . . . . . . . . . . . . . . . . . 1TL1-2G . . . . . . . . . . . . . . . . . . . . . 1TL1-3 . . . . . . . . . . . . . . . . . . . . . . . 1TL1-3D . . . . . . . . . . . . . . . . . . . . . 1TL1-5 . . . . . . . . . . . . . . . . . . . . . . . 1TL1-6 . . . . . . . . . . . . . . . . . . . . . . . 1TL1-61 . . . . . . . . . . . . . . . . . . . . . . 1TL1-7 . . . . . . . . . . . . . . . . . . . . . . . 1TL1-7E . . . . . . . . . . . . . . . . . . . . . . 1TL1-8 . . . . . . . . . . . . . . . . . . . . . . . 1TL1-8F . . . . . . . . . . . . . . . . . . . . . . 1TL150-3D . . . . . . . . . . . . . . . . . . . 1TP1-6 . . . . . . . . . . . . . . . . . . . . . . 1TP12-7 . . . . . . . . . . . . . . . . . . . . . 1TP201-7 . . . . . . . . . . . . . . . . . . . . 1TP8-2 . . . . . . . . . . . . . . . . . . . . . . 1TP8-3 . . . . . . . . . . . . . . . . . . . . . . 1TP8-7 . . . . . . . . . . . . . . . . . . . . . . 1TW1-3 . . . . . . . . . . . . . . . . . . . . . . 1XE1 . . . . . . . . . . . . . . . . . . . . . . . . 1XE1-T . . . . . . . . . . . . . . . . . . . . . . 1XE201 . . . . . . . . . . . . . . . . . . . . . . 1XE3 . . . . . . . . . . . . . . . . . . . . . . . . 1XE301 . . . . . . . . . . . . . . . . . . . . . . 1XE401-6 . . . . . . . . . . . . . . . . . . . . 1XE401-T . . . . . . . . . . . . . . . . . . . . 1XE99-T . . . . . . . . . . . . . . . . . . . . . 152 151 151 151 151 151 152 151 152 152 152 151 151 152 152 151 152 122 122 122 122 122 122 106 105 142 142 141 142 141 141 141 141 142 141 142 142 142 141 141 141 158 158 158 158 158 158 144 124 124 124 124 124 124 124 124 www.honeywell.com/sensing 20001 . . . . . . . . . . . . . . . . . . . . . . . 20007 . . . . . . . . . . . . . . . . . . . . . . . 20016 . . . . . . . . . . . . . . . . . . . . . . . 20017 . . . . . . . . . . . . . . . . . . . . . . . 20018 . . . . . . . . . . . . . . . . . . . . . . . 20019 . . . . . . . . . . . . . . . . . . . . . . . 2001EN1-6 . . . . . . . . . . . . . . . . . . . 20028 . . . . . . . . . . . . . . . . . . . . . . . 20029 . . . . . . . . . . . . . . . . . . . . . . . 20HM1-1 . . . . . . . . . . . . . . . . . . . . . 21CX14 . . . . . . . . . . . . . . . . . . . . . . . 21CX4 . . . . . . . . . . . . . . . . . . . . . . . . 21EN75-R1 . . . . . . . . . . . . . . . . . . . 21EN9-6 . . . . . . . . . . . . . . . . . . . . . 22HR1-S . . . . . . . . . . . . . . . . . . . . . 24CE1-S12B . . . . . . . . . . . . . . . . . . . 24CE1-S2 . . . . . . . . . . . . . . . . . . . . . 24CE1-S2A . . . . . . . . . . . . . . . . . . . . 24CE1-S2B . . . . . . . . . . . . . . . . . . . . 24CE1-S3 . . . . . . . . . . . . . . . . . . . . . 24CE1-S6 . . . . . . . . . . . . . . . . . . . . . 24CE1-Y1A . . . . . . . . . . . . . . . . . . . . 24CE1-Y2 . . . . . . . . . . . . . . . . . . . . . 24CE1-Y3 . . . . . . . . . . . . . . . . . . . . . 24CE16-S1 . . . . . . . . . . . . . . . . . . . . 24CE16-Y1 . . . . . . . . . . . . . . . . . . . . 24CE16-Y6 . . . . . . . . . . . . . . . . . . . . 24CE2-S1 . . . . . . . . . . . . . . . . . . . . . 24CE2-S2 . . . . . . . . . . . . . . . . . . . . . 24CE2-S2A . . . . . . . . . . . . . . . . . . . . 24CE2-S2B . . . . . . . . . . . . . . . . . . . . 24CE2-S3 . . . . . . . . . . . . . . . . . . . . . 24CE2-S6 . . . . . . . . . . . . . . . . . . . . . 24CE2-T2 . . . . . . . . . . . . . . . . . . . . . 24CE2-Y1 . . . . . . . . . . . . . . . . . . . . . 24CE2-Y2 . . . . . . . . . . . . . . . . . . . . . 24CE2-Y2A . . . . . . . . . . . . . . . . . . . . 24CE2-Y4 . . . . . . . . . . . . . . . . . . . . . 24CE2-Y6A . . . . . . . . . . . . . . . . . . . . 24CE28-S2 . . . . . . . . . . . . . . . . . . . . 24CE3-S2 . . . . . . . . . . . . . . . . . . . . . 24CE3-Y1 . . . . . . . . . . . . . . . . . . . . . 24CE3-Y2 . . . . . . . . . . . . . . . . . . . . . 24CE31-S1 . . . . . . . . . . . . . . . . . . . . 24CE31-S2 . . . . . . . . . . . . . . . . . . . . 24CE31-S2B . . . . . . . . . . . . . . . . . . . 24CE31-S5 . . . . . . . . . . . . . . . . . . . . 24CE31-Y1 . . . . . . . . . . . . . . . . . . . . 24CE31-Y2 . . . . . . . . . . . . . . . . . . . . 24CE31-Y3 . . . . . . . . . . . . . . . . . . . . 24CE55-S1 . . . . . . . . . . . . . . . . . . . . 24CE55-S2 . . . . . . . . . . . . . . . . . . . . 24CE55-Y1 . . . . . . . . . . . . . . . . . . . . 24CX12 . . . . . . . . . . . . . . . . . . . . . . . 24CX2 . . . . . . . . . . . . . . . . . . . . . . . . 25ET1-T-F . . . . . . . . . . . . . . . . . . . . 182 182 182 182 182 182 134 182 182 126 65 65 134 134 138 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 28 28 28 28 28 28 28 28 28 28 28 28 28 28 65 65 148 INDEX 25ET117-T . . . . . . . . . . . . . . . . . . . . 25ET61-6 . . . . . . . . . . . . . . . . . . . . . 25ET61-S . . . . . . . . . . . . . . . . . . . . 25ET61-S-F . . . . . . . . . . . . . . . . . . . 25ET61-T . . . . . . . . . . . . . . . . . . . . . 25ET62-6 . . . . . . . . . . . . . . . . . . . . . 25ET64-6 . . . . . . . . . . . . . . . . . . . . . 26900 . . . . . . . . . . . . . . . . . . . . . . . 26901 . . . . . . . . . . . . . . . . . . . . . . . 26902 . . . . . . . . . . . . . . . . . . . . . . . 26903 . . . . . . . . . . . . . . . . . . . . . . . 26904 . . . . . . . . . . . . . . . . . . . . . . . 26905 . . . . . . . . . . . . . . . . . . . . . . . 26906 . . . . . . . . . . . . . . . . . . . . . . . 26907 . . . . . . . . . . . . . . . . . . . . . . . 26908 . . . . . . . . . . . . . . . . . . . . . . . 26909 . . . . . . . . . . . . . . . . . . . . . . . 26911 . . . . . . . . . . . . . . . . . . . . . . . 26912 . . . . . . . . . . . . . . . . . . . . . . . 26913 . . . . . . . . . . . . . . . . . . . . . . . 26914 . . . . . . . . . . . . . . . . . . . . . . . 26CX4 . . . . . . . . . . . . . . . . . . . . . . . . 26ET1-R-F . . . . . . . . . . . . . . . . . . . . 26ET1-T-F . . . . . . . . . . . . . . . . . . . . 26ET107-T . . . . . . . . . . . . . . . . . . . . 26ET61-T . . . . . . . . . . . . . . . . . . . . . 26ET65-T . . . . . . . . . . . . . . . . . . . . . 27ET118-T2-N . . . . . . . . . . . . . . . . . 27ET2-6-E . . . . . . . . . . . . . . . . . . . . 27ET61-T . . . . . . . . . . . . . . . . . . . . . 27ET61-T-E . . . . . . . . . . . . . . . . . . . 27ET71-T . . . . . . . . . . . . . . . . . . . . . 27ET71-T-E . . . . . . . . . . . . . . . . . . . 28000 . . . . . . . . . . . . . . . . . . . . . . . 28002 . . . . . . . . . . . . . . . . . . . . . . . 28004 . . . . . . . . . . . . . . . . . . . . . . . 28006 . . . . . . . . . . . . . . . . . . . . . . . 28030 . . . . . . . . . . . . . . . . . . . . . . . 281CX12 . . . . . . . . . . . . . . . . . . . . . . 281CX2 . . . . . . . . . . . . . . . . . . . . . . . 29ET3 . . . . . . . . . . . . . . . . . . . . . . . 2CPSA1A1 . . . . . . . . . . . . . . . . . . . 2CPSA1A1A . . . . . . . . . . . . . . . . . . 2CPSA1A1B . . . . . . . . . . . . . . . . . . 2CPSA1A2 . . . . . . . . . . . . . . . . . . . 2CPSA1A2A . . . . . . . . . . . . . . . . . . 2CPSA1A2B . . . . . . . . . . . . . . . . . . 2CPSA1A3 . . . . . . . . . . . . . . . . . . . 2CPSA1A3A . . . . . . . . . . . . . . . . . . 2CPSA1A3B . . . . . . . . . . . . . . . . . . 2CPSA1B1 . . . . . . . . . . . . . . . . . . . 2CPSA1B1A . . . . . . . . . . . . . . . . . . 2CPSA1B1B . . . . . . . . . . . . . . . . . . 2CPSA1B2 . . . . . . . . . . . . . . . . . . . 2CPSA1B2A . . . . . . . . . . . . . . . . . . 2CPSA1B2B . . . . . . . . . . . . . . . . . . 148 148 148 148 148 148 148 117 117 117 117 117 117 117 117 117 117 117 117 117 117 65 148 148 148 148 148 148 148 148 148 148 148 183 183 183 183 183 65 65 148 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 2CPSA1B3 . . . . . . . . . . . . . . . . . . . 2CPSA1B3A . . . . . . . . . . . . . . . . . . 2CPSA1B3B . . . . . . . . . . . . . . . . . . 2CPSA2A1 . . . . . . . . . . . . . . . . . . . 2CPSA2A1A . . . . . . . . . . . . . . . . . . 2CPSA2A1B . . . . . . . . . . . . . . . . . . 2CPSA2A2 . . . . . . . . . . . . . . . . . . . 2CPSA2A2A . . . . . . . . . . . . . . . . . . 2CPSA2A2B . . . . . . . . . . . . . . . . . . 2CPSA2A3 . . . . . . . . . . . . . . . . . . . 2CPSA2A3A . . . . . . . . . . . . . . . . . . 2CPSA2A3B . . . . . . . . . . . . . . . . . . 2CPSA2B1 . . . . . . . . . . . . . . . . . . . 2CPSA2B1A . . . . . . . . . . . . . . . . . . 2CPSA2B1B . . . . . . . . . . . . . . . . . . 2CPSC1A1 . . . . . . . . . . . . . . . . . . . 2CPSC1A1A . . . . . . . . . . . . . . . . . . 2CPSC1A2 . . . . . . . . . . . . . . . . . . . 2CPSC1A2A . . . . . . . . . . . . . . . . . . 2CPSC1A3 . . . . . . . . . . . . . . . . . . . 2CPSC1A3A . . . . . . . . . . . . . . . . . . 2CPSC1D1A . . . . . . . . . . . . . . . . . . 2EN1-6 . . . . . . . . . . . . . . . . . . . . . . 2EX1 . . . . . . . . . . . . . . . . . . . . . . . . . 2HM19-1 . . . . . . . . . . . . . . . . . . . . . 2HM19-5 . . . . . . . . . . . . . . . . . . . . . 2HT1 . . . . . . . . . . . . . . . . . . . . . . . . 2LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 2LS1-4C . . . . . . . . . . . . . . . . . . . . . . 2LS1-L . . . . . . . . . . . . . . . . . . . . . . . 2LS111 . . . . . . . . . . . . . . . . . . . . . . . 2NT1-1 . . . . . . . . . . . . . . . . . . . . . . 2NT1-1-NH . . . . . . . . . . . . . . . . . . . 2NT1-10 . . . . . . . . . . . . . . . . . . . . . 2NT1-2 . . . . . . . . . . . . . . . . . . . . . . 2NT1-3 . . . . . . . . . . . . . . . . . . . . . . 2NT1-3-NH . . . . . . . . . . . . . . . . . . . 2NT1-5 . . . . . . . . . . . . . . . . . . . . . . 2NT1-50 . . . . . . . . . . . . . . . . . . . . . 2NT1-7 . . . . . . . . . . . . . . . . . . . . . . 2NT1-7-NH . . . . . . . . . . . . . . . . . . . 2NT1-70 . . . . . . . . . . . . . . . . . . . . . 2NT1-8 . . . . . . . . . . . . . . . . . . . . . . 2NT1-8-NH . . . . . . . . . . . . . . . . . . . 2NT231-7 . . . . . . . . . . . . . . . . . . . . 2NT889-70 . . . . . . . . . . . . . . . . . . . 2NT91-7 . . . . . . . . . . . . . . . . . . . . . 2TL1-1 . . . . . . . . . . . . . . . . . . . . . . . 2TL1-10 . . . . . . . . . . . . . . . . . . . . . . 2TL1-10A . . . . . . . . . . . . . . . . . . . . 2TL1-12 . . . . . . . . . . . . . . . . . . . . . . 2TL1-1A . . . . . . . . . . . . . . . . . . . . . 2TL1-2 . . . . . . . . . . . . . . . . . . . . . . . 2TL1-21 . . . . . . . . . . . . . . . . . . . . . . 2TL1-2D . . . . . . . . . . . . . . . . . . . . . 2TL1-3 . . . . . . . . . . . . . . . . . . . . . . . 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 101 133 61 126 126 130 32 32 32 32 152 152 152 151 151 151 152 152 152 152 152 151 151 152 152 152 142 142 142 142 142 141 142 141 142 www.honeywell.com/sensing 2TL1-31K . . . . . . . . . . . . . . . . . . . . 2TL1-3D . . . . . . . . . . . . . . . . . . . . . 2TL1-3G . . . . . . . . . . . . . . . . . . . . . 2TL1-5 . . . . . . . . . . . . . . . . . . . . . . . 2TL1-50 . . . . . . . . . . . . . . . . . . . . . . 2TL1-56 . . . . . . . . . . . . . . . . . . . . . . 2TL1-6 . . . . . . . . . . . . . . . . . . . . . . . 2TL1-7 . . . . . . . . . . . . . . . . . . . . . . . 2TL1-70 . . . . . . . . . . . . . . . . . . . . . . 2TL1-70E . . . . . . . . . . . . . . . . . . . . . 2TL1-8 . . . . . . . . . . . . . . . . . . . . . . . 2TL1-8F . . . . . . . . . . . . . . . . . . . . . . 2TP1-7 . . . . . . . . . . . . . . . . . . . . . . 2TP12-7 . . . . . . . . . . . . . . . . . . . . . 2TP216-7 . . . . . . . . . . . . . . . . . . . . 2TP216-8 . . . . . . . . . . . . . . . . . . . . 2TP7-3 . . . . . . . . . . . . . . . . . . . . . . 311SX5-T . . . . . . . . . . . . . . . . . . . . 31EN1-6 . . . . . . . . . . . . . . . . . . . . . 31EN11-6 . . . . . . . . . . . . . . . . . . . . 31NT91-1 . . . . . . . . . . . . . . . . . . . . 31NT91-2 . . . . . . . . . . . . . . . . . . . . 31NT91-3 . . . . . . . . . . . . . . . . . . . . 31NT91-6 . . . . . . . . . . . . . . . . . . . . 31NT91-7 . . . . . . . . . . . . . . . . . . . . 32EN1-6 . . . . . . . . . . . . . . . . . . . . . 32EN11-6 . . . . . . . . . . . . . . . . . . . . 32NT291-3G . . . . . . . . . . . . . . . . . . 32NT291-5E . . . . . . . . . . . . . . . . . . 32NT91-1 . . . . . . . . . . . . . . . . . . . . 32NT91-2 . . . . . . . . . . . . . . . . . . . . 32NT91-3 . . . . . . . . . . . . . . . . . . . . 32NT91-7 . . . . . . . . . . . . . . . . . . . . 32NT91-7-NH . . . . . . . . . . . . . . . . . 32NT94-70L . . . . . . . . . . . . . . . . . . 33EN1-6 . . . . . . . . . . . . . . . . . . . . . 33EN11-6 . . . . . . . . . . . . . . . . . . . . 34EN1-6 . . . . . . . . . . . . . . . . . . . . . 34EN11-6 . . . . . . . . . . . . . . . . . . . . 3EN1-6 . . . . . . . . . . . . . . . . . . . . . . 3HT1 . . . . . . . . . . . . . . . . . . . . . . . . 3LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 3LS1-4C . . . . . . . . . . . . . . . . . . . . . . 402EN1-6 . . . . . . . . . . . . . . . . . . . . 404EN1-6 . . . . . . . . . . . . . . . . . . . . 41EN1-6 . . . . . . . . . . . . . . . . . . . . . 42EN1-6 . . . . . . . . . . . . . . . . . . . . . 44EN1-6 . . . . . . . . . . . . . . . . . . . . . 4EN1-6 . . . . . . . . . . . . . . . . . . . . . . 4EX1-3 . . . . . . . . . . . . . . . . . . . . . . . 4HS4-118 . . . . . . . . . . . . . . . . . . . . 4LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 4LS1-4C . . . . . . . . . . . . . . . . . . . . . . 4NT1-1 . . . . . . . . . . . . . . . . . . . . . . 4NT1-1A . . . . . . . . . . . . . . . . . . . . . 4NT1-3 . . . . . . . . . . . . . . . . . . . . . . 142 142 142 142 142 142 141 142 142 142 142 142 158 158 158 158 158 106 135 135 154 153 153 153 154 135 135 153 154 154 153 153 154 154 154 135 135 135 135 133 130 32 32 136 136 135 135 135 133 61 129 32 32 152 152 151 201 INDEX 4SE1 . . . . . . . . . . . . . . . . . . . . . . . . 4TL1-2 . . . . . . . . . . . . . . . . . . . . . . . 4TL1-3 . . . . . . . . . . . . . . . . . . . . . . . 4TL1-3D . . . . . . . . . . . . . . . . . . . . . 4TL1-7 . . . . . . . . . . . . . . . . . . . . . . . 4TL1-8 . . . . . . . . . . . . . . . . . . . . . . . 4XE1 . . . . . . . . . . . . . . . . . . . . . . . . 5LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 5LS1-4C . . . . . . . . . . . . . . . . . . . . . . 5LS1-L . . . . . . . . . . . . . . . . . . . . . . . 5SE1 . . . . . . . . . . . . . . . . . . . . . . . . 5XE1 . . . . . . . . . . . . . . . . . . . . . . . . 602EN1-6 . . . . . . . . . . . . . . . . . . . . 602EN222-6 . . . . . . . . . . . . . . . . . . 602HE1-6 . . . . . . . . . . . . . . . . . . . . 602HE106-6 . . . . . . . . . . . . . . . . . . 604EN1-6 . . . . . . . . . . . . . . . . . . . . 604EN222-6 . . . . . . . . . . . . . . . . . . 604HE1-6 . . . . . . . . . . . . . . . . . . . . 61NT1-7 . . . . . . . . . . . . . . . . . . . . . 622EN1-6 . . . . . . . . . . . . . . . . . . . . 622EN222-6 . . . . . . . . . . . . . . . . . . 622HE1-6 . . . . . . . . . . . . . . . . . . . . 624EN1-6 . . . . . . . . . . . . . . . . . . . . 624EN222-6 . . . . . . . . . . . . . . . . . . 624HE1-6 . . . . . . . . . . . . . . . . . . . . 64AT22-3 . . . . . . . . . . . . . . . . . . . . . 64AT34-7E . . . . . . . . . . . . . . . . . . . . 6AT124-T . . . . . . . . . . . . . . . . . . . . . 6HM1-1 . . . . . . . . . . . . . . . . . . . . . . 6LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 6LS1-4C . . . . . . . . . . . . . . . . . . . . . . 6LS2 . . . . . . . . . . . . . . . . . . . . . . . . . 6LS2-L . . . . . . . . . . . . . . . . . . . . . . . 6LS3 . . . . . . . . . . . . . . . . . . . . . . . . . 6PA102 . . . . . . . . . . . . . . . . . . . . . . . 6PA127-EX . . . . . . . . . . . . . . . . . . . . 6PA130-EX . . . . . . . . . . . . . . . . . . . . 6PA131-EX . . . . . . . . . . . . . . . . . . . . 6PA136-EX . . . . . . . . . . . . . . . . . . . . 6PA138-EX . . . . . . . . . . . . . . . . . . . . 6PA142-EX . . . . . . . . . . . . . . . . . . . . 6PA144 . . . . . . . . . . . . . . . . . . . . . . . 6PA204-EX . . . . . . . . . . . . . . . . . . . . 6PA5-EX . . . . . . . . . . . . . . . . . . . . . . 6PA57 . . . . . . . . . . . . . . . . . . . . . . . . 6PA63 . . . . . . . . . . . . . . . . . . . . . . . . 6PA69 . . . . . . . . . . . . . . . . . . . . . . . . 6PA80 . . . . . . . . . . . . . . . . . . . . . . . . 6PA82 . . . . . . . . . . . . . . . . . . . . . . . . 6SX7-T . . . . . . . . . . . . . . . . . . . . . . 71017 . . . . . . . . . . . . . . . . . . . . . . . 71723 . . . . . . . . . . . . . . . . . . . . . . . 71792 . . . . . . . . . . . . . . . . . . . . . . . 71794 . . . . . . . . . . . . . . . . . . . . . . . 71898 . . . . . . . . . . . . . . . . . . . . . . . 202 122 141 141 141 142 141 124 32 32 32 122 124 136 136 137 137 136 136 137 152 136 136 137 136 136 137 146 146 146 126 31 31 31 31 31 72 72 72 72 72 72 72 72 72 72 73 72 72 72 72 106 190 192 190 190 189 71902 71915 72108 72408 72530 72540 72541 72542 72543 72544 72545 72656 72666 72715 72716 72717 72718 72719 72720 72728 72801 73468 73469 73761 73763 73764 73804 74041 76051 76052 76053 76054 76055 76061 76062 76063 76064 76065 76575 76576 76577 76578 77342 77343 78628 78632 78813 78815 79700 79702 79704 79708 79710 79718 79719 79720 ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... 189 189 192 190 192 189 190 189 190 189 190 192 192 192 192 192 192 192 192 192 190 190 190 189 189 189 190 192 114 114 114 114 114 114 114 114 114 114 114 114 114 114 115 115 114 114 115 115 115 115 115 115 115 115 115 115 www.honeywell.com/sensing 79721 . . . . . . . . . . . . . . . . . . . . . . . 79722 . . . . . . . . . . . . . . . . . . . . . . . 79723 . . . . . . . . . . . . . . . . . . . . . . . 79809 . . . . . . . . . . . . . . . . . . . . . . . 7SE1 . . . . . . . . . . . . . . . . . . . . . . . . 80260 . . . . . . . . . . . . . . . . . . . . . . . 80262 . . . . . . . . . . . . . . . . . . . . . . . 80279 . . . . . . . . . . . . . . . . . . . . . . . 80350 . . . . . . . . . . . . . . . . . . . . . . . 80413 . . . . . . . . . . . . . . . . . . . . . . . 80438 . . . . . . . . . . . . . . . . . . . . . . . 80510 . . . . . . . . . . . . . . . . . . . . . . . 80876 . . . . . . . . . . . . . . . . . . . . . . . 80877 . . . . . . . . . . . . . . . . . . . . . . . 80909 . . . . . . . . . . . . . . . . . . . . . . . 80910 . . . . . . . . . . . . . . . . . . . . . . . 81248 . . . . . . . . . . . . . . . . . . . . . . . 81426 . . . . . . . . . . . . . . . . . . . . . . . 81521 . . . . . . . . . . . . . . . . . . . . . . . 81601 . . . . . . . . . . . . . . . . . . . . . . . 81705 . . . . . . . . . . . . . . . . . . . . . . . 81758 . . . . . . . . . . . . . . . . . . . . . . . 81CX14 . . . . . . . . . . . . . . . . . . . . . . . 81CX2 . . . . . . . . . . . . . . . . . . . . . . . . 81CX4 . . . . . . . . . . . . . . . . . . . . . . . . 82320 . . . . . . . . . . . . . . . . . . . . . . . 82400 . . . . . . . . . . . . . . . . . . . . . . . 82401 . . . . . . . . . . . . . . . . . . . . . . . 82404 . . . . . . . . . . . . . . . . . . . . . . . 82416 . . . . . . . . . . . . . . . . . . . . . . . 82570 . . . . . . . . . . . . . . . . . . . . . . . 83298 . . . . . . . . . . . . . . . . . . . . . . . 83299 . . . . . . . . . . . . . . . . . . . . . . . 83301 . . . . . . . . . . . . . . . . . . . . . . . 83302 . . . . . . . . . . . . . . . . . . . . . . . 83304 . . . . . . . . . . . . . . . . . . . . . . . 83305 . . . . . . . . . . . . . . . . . . . . . . . 83307 . . . . . . . . . . . . . . . . . . . . . . . 83308 . . . . . . . . . . . . . . . . . . . . . . . 83310 . . . . . . . . . . . . . . . . . . . . . . . 83311 . . . . . . . . . . . . . . . . . . . . . . . 84105 . . . . . . . . . . . . . . . . . . . . . . . 84467 . . . . . . . . . . . . . . . . . . . . . . . 84760-50 . . . . . . . . . . . . . . . . . . . . . 84825 . . . . . . . . . . . . . . . . . . . . . . . 84826 . . . . . . . . . . . . . . . . . . . . . . . 84828 . . . . . . . . . . . . . . . . . . . . . . . 84829 . . . . . . . . . . . . . . . . . . . . . . . 84830 . . . . . . . . . . . . . . . . . . . . . . . 84884 . . . . . . . . . . . . . . . . . . . . . . . 84CX2 . . . . . . . . . . . . . . . . . . . . . . . . 85010 . . . . . . . . . . . . . . . . . . . . . . . 85093 . . . . . . . . . . . . . . . . . . . . . . . 85094 . . . . . . . . . . . . . . . . . . . . . . . 85097 . . . . . . . . . . . . . . . . . . . . . . . 85331 . . . . . . . . . . . . . . . . . . . . . . . 115 115 115 188 122 186 186 188 188 191 186 191 186 188 186 186 186 186 186 188 188 186 65 65 65 180 181 181 182 181 188 116 116 116 116 116 116 116 116 116 116 186 186 191 184 184 184 184 184 188 65 180 181 180 180 180 INDEX 85342 . . . . . . . . . . . . . . . . . . . . . . . 85874 . . . . . . . . . . . . . . . . . . . . . . . 86320 . . . . . . . . . . . . . . . . . . . . . . . 86508 . . . . . . . . . . . . . . . . . . . . . . . 86835 . . . . . . . . . . . . . . . . . . . . . . . 87941 . . . . . . . . . . . . . . . . . . . . . . . 87943 . . . . . . . . . . . . . . . . . . . . . . . 88217-50 . . . . . . . . . . . . . . . . . . . . . 88432 . . . . . . . . . . . . . . . . . . . . . . . 88735-50 . . . . . . . . . . . . . . . . . . . . . 88913-50 . . . . . . . . . . . . . . . . . . . . . 89165 . . . . . . . . . . . . . . . . . . . . . . . 89444 . . . . . . . . . . . . . . . . . . . . . . . 89445 . . . . . . . . . . . . . . . . . . . . . . . 89446 . . . . . . . . . . . . . . . . . . . . . . . 89447 . . . . . . . . . . . . . . . . . . . . . . . 89448 . . . . . . . . . . . . . . . . . . . . . . . 89477 . . . . . . . . . . . . . . . . . . . . . . . 8LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 8LS1-4C . . . . . . . . . . . . . . . . . . . . . . 8LS1-L . . . . . . . . . . . . . . . . . . . . . . . 8LS125 . . . . . . . . . . . . . . . . . . . . . . . 8LS125-4C . . . . . . . . . . . . . . . . . . . . 8LS152 . . . . . . . . . . . . . . . . . . . . . . . 8LS152-4C . . . . . . . . . . . . . . . . . . . . 8LS3 . . . . . . . . . . . . . . . . . . . . . . . . . 8LS3-4C . . . . . . . . . . . . . . . . . . . . . . 914CE1-3 . . . . . . . . . . . . . . . . . . . . . 914CE1-3A . . . . . . . . . . . . . . . . . . . . 914CE1-3G . . . . . . . . . . . . . . . . . . . . 914CE1-6 . . . . . . . . . . . . . . . . . . . . . 914CE1-6G . . . . . . . . . . . . . . . . . . . . 914CE1-9 . . . . . . . . . . . . . . . . . . . . . 914CE1-Q . . . . . . . . . . . . . . . . . . . . . 914CE1-Q1 . . . . . . . . . . . . . . . . . . . . 914CE16-3 . . . . . . . . . . . . . . . . . . . . 914CE16-3A . . . . . . . . . . . . . . . . . . . 914CE16-6 . . . . . . . . . . . . . . . . . . . . 914CE16-9 . . . . . . . . . . . . . . . . . . . . 914CE16-Q . . . . . . . . . . . . . . . . . . . . 914CE18-3 . . . . . . . . . . . . . . . . . . . . 914CE18-3A . . . . . . . . . . . . . . . . . . . 914CE18-6 . . . . . . . . . . . . . . . . . . . . 914CE18-9 . . . . . . . . . . . . . . . . . . . . 914CE18-9A . . . . . . . . . . . . . . . . . . . 914CE18-AQ1 . . . . . . . . . . . . . . . . . . 914CE18-Q . . . . . . . . . . . . . . . . . . . . 914CE18-Q1 . . . . . . . . . . . . . . . . . . . 914CE19-3 . . . . . . . . . . . . . . . . . . . . 914CE19-9 . . . . . . . . . . . . . . . . . . . . 914CE2-3 . . . . . . . . . . . . . . . . . . . . . 914CE2-3A . . . . . . . . . . . . . . . . . . . . 914CE2-3G . . . . . . . . . . . . . . . . . . . . 914CE2-6 . . . . . . . . . . . . . . . . . . . . . 914CE2-6A . . . . . . . . . . . . . . . . . . . . 914CE2-9 . . . . . . . . . . . . . . . . . . . . . 181 186 188 188 186 185 185 191 193 191 191 184 193 193 193 193 193 184 33 33 33 33 33 33 33 33 33 24 24 24 24 24 24 24 24 25 25 25 25 25 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 914CE2-AQ . . . . . . . . . . . . . . . . . . . . 914CE2-Q . . . . . . . . . . . . . . . . . . . . . 914CE2-Q1 . . . . . . . . . . . . . . . . . . . . 914CE20-3 . . . . . . . . . . . . . . . . . . . . 914CE20-6 . . . . . . . . . . . . . . . . . . . . 914CE20-9 . . . . . . . . . . . . . . . . . . . . 914CE20-Q . . . . . . . . . . . . . . . . . . . . 914CE22-6 . . . . . . . . . . . . . . . . . . . . 914CE27-Q . . . . . . . . . . . . . . . . . . . . 914CE28-3 . . . . . . . . . . . . . . . . . . . . 914CE28-6 . . . . . . . . . . . . . . . . . . . . 914CE28-Q . . . . . . . . . . . . . . . . . . . . 914CE29-3 . . . . . . . . . . . . . . . . . . . . 914CE29-6 . . . . . . . . . . . . . . . . . . . . 914CE3-3 . . . . . . . . . . . . . . . . . . . . . 914CE3-6 . . . . . . . . . . . . . . . . . . . . . 914CE3-6A . . . . . . . . . . . . . . . . . . . . 914CE3-9 . . . . . . . . . . . . . . . . . . . . . 914CE3-Q . . . . . . . . . . . . . . . . . . . . . 914CE3-Q1 . . . . . . . . . . . . . . . . . . . . 914CE31-3 . . . . . . . . . . . . . . . . . . . . 914CE31-6 . . . . . . . . . . . . . . . . . . . . 914CE55-3 . . . . . . . . . . . . . . . . . . . . 914CE55-3A . . . . . . . . . . . . . . . . . . . 914CE66-3 . . . . . . . . . . . . . . . . . . . . 914CE66-6 . . . . . . . . . . . . . . . . . . . . 924CE1-S3 . . . . . . . . . . . . . . . . . . . . 924CE1-S6 . . . . . . . . . . . . . . . . . . . . 924CE1-S9 . . . . . . . . . . . . . . . . . . . . 924CE1-T25A . . . . . . . . . . . . . . . . . . 924CE1-T3 . . . . . . . . . . . . . . . . . . . . 924CE1-T3A . . . . . . . . . . . . . . . . . . . 924CE1-T6A . . . . . . . . . . . . . . . . . . . 924CE1-T9 . . . . . . . . . . . . . . . . . . . . 924CE1-T9A . . . . . . . . . . . . . . . . . . . 924CE1-Y3 . . . . . . . . . . . . . . . . . . . . 924CE1-Y9 . . . . . . . . . . . . . . . . . . . . 924CE16-S3 . . . . . . . . . . . . . . . . . . . 924CE16-S9 . . . . . . . . . . . . . . . . . . . 924CE16-T3 . . . . . . . . . . . . . . . . . . . 924CE16-Y3 . . . . . . . . . . . . . . . . . . . 924CE16-Y9 . . . . . . . . . . . . . . . . . . . 924CE18-S6 . . . . . . . . . . . . . . . . . . . 924CE19-S3L1 . . . . . . . . . . . . . . . . . 924CE2-S15 . . . . . . . . . . . . . . . . . . . 924CE2-S21 . . . . . . . . . . . . . . . . . . . 924CE2-S3 . . . . . . . . . . . . . . . . . . . . 924CE2-S6 . . . . . . . . . . . . . . . . . . . . 924CE2-S6A . . . . . . . . . . . . . . . . . . . 924CE2-S9 . . . . . . . . . . . . . . . . . . . . 924CE2-T25 . . . . . . . . . . . . . . . . . . . 924CE2-T25A . . . . . . . . . . . . . . . . . . 924CE2-T3 . . . . . . . . . . . . . . . . . . . . 924CE2-T6 . . . . . . . . . . . . . . . . . . . . 924CE2-T9 . . . . . . . . . . . . . . . . . . . . 924CE2-Y3 . . . . . . . . . . . . . . . . . . . . 24 24 24 25 25 25 25 24 24 24 24 24 25 25 25 25 25 25 25 25 24 24 25 25 24 24 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 www.honeywell.com/sensing 924CE2-Y9 . . . . . . . . . . . . . . . . . . . . 924CE28-S15 . . . . . . . . . . . . . . . . . . 924CE3-S3 . . . . . . . . . . . . . . . . . . . . 924CE3-S6 . . . . . . . . . . . . . . . . . . . . 924CE3-S9 . . . . . . . . . . . . . . . . . . . . 924CE3-T9 . . . . . . . . . . . . . . . . . . . . 924CE31-S6 . . . . . . . . . . . . . . . . . . . 924CE31-Y20 . . . . . . . . . . . . . . . . . . 924CE31-Y3L1 . . . . . . . . . . . . . . . . . 98101 . . . . . . . . . . . . . . . . . . . . . . . 98102 . . . . . . . . . . . . . . . . . . . . . . . 98103 . . . . . . . . . . . . . . . . . . . . . . . 98106 . . . . . . . . . . . . . . . . . . . . . . . 98108 . . . . . . . . . . . . . . . . . . . . . . . 98109 . . . . . . . . . . . . . . . . . . . . . . . 98110 . . . . . . . . . . . . . . . . . . . . . . . 98111 . . . . . . . . . . . . . . . . . . . . . . . 98202 . . . . . . . . . . . . . . . . . . . . . . . . 98301 . . . . . . . . . . . . . . . . . . . . . . . 98302 . . . . . . . . . . . . . . . . . . . . . . . 98303 . . . . . . . . . . . . . . . . . . . . . . . 98304 . . . . . . . . . . . . . . . . . . . . . . . 98311 . . . . . . . . . . . . . . . . . . . . . . . 98312 . . . . . . . . . . . . . . . . . . . . . . . 98313 . . . . . . . . . . . . . . . . . . . . . . . 98314 . . . . . . . . . . . . . . . . . . . . . . . 98321 . . . . . . . . . . . . . . . . . . . . . . . 98322 . . . . . . . . . . . . . . . . . . . . . . . 98323 . . . . . . . . . . . . . . . . . . . . . . . 98324 . . . . . . . . . . . . . . . . . . . . . . . 98706 . . . . . . . . . . . . . . . . . . . . . . . 98707 . . . . . . . . . . . . . . . . . . . . . . . 98750 . . . . . . . . . . . . . . . . . . . . . . . . 9HM1 . . . . . . . . . . . . . . . . . . . . . . . . 27 28 28 28 28 28 28 28 28 178 177 178 179 179 179 179 177 179 177 177 179 179 177 177 179 179 177 177 179 179 178 178 177 127 B BA-2RB-A2 . . . . . . . . . . . . . . . . . . . BA-2RQ1-A2 . . . . . . . . . . . . . . . . . . BA-2RV-A2 . . . . . . . . . . . . . . . . . . . BAF1-2RN-LH . . . . . . . . . . . . . . . . . . BAF1-2RN-RH . . . . . . . . . . . . . . . . . . BAF1-2RN18-LH . . . . . . . . . . . . . . . . BAF1-2RN18-RH . . . . . . . . . . . . . . . . BAF1-2RN2-LH . . . . . . . . . . . . . . . . . BAF1-2RN2-RH . . . . . . . . . . . . . . . . . BAF1-2RN28-LH . . . . . . . . . . . . . . . . BAF1-2RN28-RH . . . . . . . . . . . . . . . . BAF1-2RN4-LH . . . . . . . . . . . . . . . . . BAF1-2RN4-RH . . . . . . . . . . . . . . . . . BAF1-2RQ9-LH . . . . . . . . . . . . . . . . . BAF1-2RQ9-RH . . . . . . . . . . . . . . . . . BAF1-2RQN8-LH . . . . . . . . . . . . . . . . BAF1-2RQN8-RH . . . . . . . . . . . . . . . . BAF1-3CN18X1 . . . . . . . . . . . . . . . . . BAF1-3RN2X-LH . . . . . . . . . . . . . . . . BAF1-3RN2X-RH . . . . . . . . . . . . . . . . 103 103 104 42 42 44 44 43 43 43 43 44 44 43 43 43 43 45 44 44 203 INDEX BAF1-3RNX1 . . . . . . . . . . . . . . . . . . . BE-2R-A4 . . . . . . . . . . . . . . . . . . . . BF Series . . . . . . . . . . . . . . . . . . . . . . BFL1-AW1 . . . . . . . . . . . . . . . . . . . . . BFL1-AW2 . . . . . . . . . . . . . . . . . . . . . BFL1-BL1 . . . . . . . . . . . . . . . . . . . . . BFL1-BL2 . . . . . . . . . . . . . . . . . . . . . BFL1-BL3 . . . . . . . . . . . . . . . . . . . . . BFL1-BP1 . . . . . . . . . . . . . . . . . . . . . BFL1-BW1 . . . . . . . . . . . . . . . . . . . . . BFL1-BW3 . . . . . . . . . . . . . . . . . . . . . BFL1-BW4 . . . . . . . . . . . . . . . . . . . . . BFR1-BL1 . . . . . . . . . . . . . . . . . . . . . BFR1-BL2 . . . . . . . . . . . . . . . . . . . . . BFR1-BL3 . . . . . . . . . . . . . . . . . . . . . BFR1-BP1 . . . . . . . . . . . . . . . . . . . . . BFR1-BW1 . . . . . . . . . . . . . . . . . . . . . BFR1-BW4 . . . . . . . . . . . . . . . . . . . . . BX4A3K . . . . . . . . . . . . . . . . . . . . . . . BX4C3K . . . . . . . . . . . . . . . . . . . . . . . BX4C4L . . . . . . . . . . . . . . . . . . . . . . . BX4D3K . . . . . . . . . . . . . . . . . . . . . . . BXA3K . . . . . . . . . . . . . . . . . . . . . . . . BXA4L . . . . . . . . . . . . . . . . . . . . . . . . BXC4L . . . . . . . . . . . . . . . . . . . . . . . . BXF3K . . . . . . . . . . . . . . . . . . . . . . . . BXN3K . . . . . . . . . . . . . . . . . . . . . . . . BXN4L . . . . . . . . . . . . . . . . . . . . . . . . BXR3E . . . . . . . . . . . . . . . . . . . . . . . . BXR3K . . . . . . . . . . . . . . . . . . . . . . . . BXR4S . . . . . . . . . . . . . . . . . . . . . . . . BZ-2R-A2 . . . . . . . . . . . . . . . . . . . . BZ-2RD-A2 . . . . . . . . . . . . . . . . . . . BZ-2RDS-A2 . . . . . . . . . . . . . . . . . . BZ-2RDS-A2S . . . . . . . . . . . . . . . . . BZ-2RQ1-A2 . . . . . . . . . . . . . . . . . . BZ-2RQ18-A2 . . . . . . . . . . . . . . . . . BZ-2RQ181-A2 . . . . . . . . . . . . . . . . BZ-2RW80-A2 . . . . . . . . . . . . . . . . . BZ-2RW82-A2 . . . . . . . . . . . . . . . . . BZ-2RW822 . . . . . . . . . . . . . . . . . . . BZ-2RW822-A2 . . . . . . . . . . . . . . . . BZ-2RW8225551-A2 . . . . . . . . . . . . BZ-2RW826-A2 . . . . . . . . . . . . . . . . BZ-2RW863-A2 . . . . . . . . . . . . . . . . BZ-R . . . . . . . . . . . . . . . . . . . . . . . . BZ-R-A2 . . . . . . . . . . . . . . . . . . . . . BZ-R169 . . . . . . . . . . . . . . . . . . . . . BZE6-2RN . . . . . . . . . . . . . . . . . . . . . BZE6-2RN18 . . . . . . . . . . . . . . . . . . . BZE6-2RN2 . . . . . . . . . . . . . . . . . . . . BZE6-2RN234 . . . . . . . . . . . . . . . . . . BZE6-2RN28 . . . . . . . . . . . . . . . . . . . BZE6-2RN34 . . . . . . . . . . . . . . . . . . . BZE6-2RN62 . . . . . . . . . . . . . . . . . . . BZE6-2RN7 . . . . . . . . . . . . . . . . . . . . 204 44 103 34 35 35 34 35 35 34 35 35 35 34 35 35 34 35 35 67 68 68 68 67 67 68 69 67 67 67 67 67 103 103 104 104 103 104 104 104 104 104 104 104 104 104 103 103 103 37 39 38 38 39 37 39 37 BZE6-2RN72 . . . . . . . . . . . . . . . . . . . BZE6-2RN80 . . . . . . . . . . . . . . . . . . . BZE6-2RN81 . . . . . . . . . . . . . . . . . . . BZE6-2RQ . . . . . . . . . . . . . . . . . . . . . BZE6-2RQ2 . . . . . . . . . . . . . . . . . . . . BZE6-2RQ62 . . . . . . . . . . . . . . . . . . . BZE6-2RQ8 . . . . . . . . . . . . . . . . . . . . BZE6-2RQ81 . . . . . . . . . . . . . . . . . . . BZE6-2RQ9 . . . . . . . . . . . . . . . . . . . . BZE6-RN2X1 . . . . . . . . . . . . . . . . . . . BZE6-RN80X2 . . . . . . . . . . . . . . . . . . BZE6-RNX1 . . . . . . . . . . . . . . . . . . . . BZE6-RQ2X2 . . . . . . . . . . . . . . . . . . . BZE6-RQ8X2 . . . . . . . . . . . . . . . . . . . BZE6-RQX2 . . . . . . . . . . . . . . . . . . . . BZE7-2RN-C . . . . . . . . . . . . . . . . . . . BZE7-2RN-PG . . . . . . . . . . . . . . . . . . BZE7-2RN18-PG . . . . . . . . . . . . . . . . BZE7-2RN2-C . . . . . . . . . . . . . . . . . . BZE7-2RN2-PG . . . . . . . . . . . . . . . . . BZE7-2RQ-PG . . . . . . . . . . . . . . . . . . BZE7-2RQ8-PG . . . . . . . . . . . . . . . . . BZE7-2RQ81-PG . . . . . . . . . . . . . . . . BZV6-2RN . . . . . . . . . . . . . . . . . . . . . BZV6-2RN18 . . . . . . . . . . . . . . . . . . . BZV6-2RN2 . . . . . . . . . . . . . . . . . . . . BZV6-2RN4 . . . . . . . . . . . . . . . . . . . . BZV6-2RN62 . . . . . . . . . . . . . . . . . . . BZV6-2RN80 . . . . . . . . . . . . . . . . . . . BZV6-2RQ . . . . . . . . . . . . . . . . . . . . . BZV6-2RQ2 . . . . . . . . . . . . . . . . . . . . BZV6-2RQ62 . . . . . . . . . . . . . . . . . . . BZV6-2RQ8 . . . . . . . . . . . . . . . . . . . . BZV6-2RQ81 . . . . . . . . . . . . . . . . . . . 37 37 38 37 38 39 37 38 37 40 40 40 40 40 40 41 41 41 41 41 41 41 41 37 39 38 39 39 37 37 38 39 37 38 C CLSZC1 . . . . . . . . . . . . . . . . . . . . . . CLSZC2 . . . . . . . . . . . . . . . . . . . . . . CLSZC3 . . . . . . . . . . . . . . . . . . . . . . CLSZC4 . . . . . . . . . . . . . . . . . . . . . . CLSZC5 . . . . . . . . . . . . . . . . . . . . . . CLSZC7 . . . . . . . . . . . . . . . . . . . . . . CLSZTC . . . . . . . . . . . . . . . . . . . . . . CPS-BRACKET . . . . . . . . . . . . . . . . CPSLED120 . . . . . . . . . . . . . . . . . . . CPSLED24 . . . . . . . . . . . . . . . . . . . . CPSZ1S . . . . . . . . . . . . . . . . . . . . . . CPSZK1 . . . . . . . . . . . . . . . . . . . . . . CPSZTB . . . . . . . . . . . . . . . . . . . . . . Custom Switches & Assemblies . . . . Cargo Loading Systems . . . . . . . . Flap Selectors . . . . . . . . . . . . . . . Gear Selectors . . . . . . . . . . . . . . . Harness Assemblies . . . . . . . . . . . Operator Interface Products . . . . . Rotary Switches . . . . . . . . . . . . . . 102 102 102 102 102 102 102 102 102 102 102 102 102 173 174 174 174 173 173 173 www.honeywell.com/sensing Switch Assemblies . . . . . . . . . . . . 173 DT-2R-A7 . . . . . . . . . . . . . . . . . . . . . DTE6-2RN . . . . . . . . . . . . . . . . . . . . . DTE6-2RN2 . . . . . . . . . . . . . . . . . . . . DTE6-2RN80 . . . . . . . . . . . . . . . . . . . DTE6-2RQ . . . . . . . . . . . . . . . . . . . . . DTE6-2RQ81 . . . . . . . . . . . . . . . . . . . DTE6-2RQ9 . . . . . . . . . . . . . . . . . . . . DTE7-2RN-PG . . . . . . . . . . . . . . . . . . DTF2-2RN-LH . . . . . . . . . . . . . . . . . . DTF2-2RN-RH . . . . . . . . . . . . . . . . . . DTF2-2RN2-LH . . . . . . . . . . . . . . . . . DTF2-2RN2-RH . . . . . . . . . . . . . . . . . DTF2-2RQ9-LH . . . . . . . . . . . . . . . . . DTF2-2RQ9-RH . . . . . . . . . . . . . . . . . DTF2-2RQN8-LH . . . . . . . . . . . . . . . . DTF2-2RQN8-RH . . . . . . . . . . . . . . . . DTV6-2RN . . . . . . . . . . . . . . . . . . . . . DTV6-2RN2 . . . . . . . . . . . . . . . . . . . . 105 37 38 37 37 38 37 41 42 42 43 43 43 43 43 43 37 38 D E EVN2000A . . . . . . . . . . . . . . . . . . . . . EVN2000B . . . . . . . . . . . . . . . . . . . . . EVN2000C . . . . . . . . . . . . . . . . . . . . . EVN2000D . . . . . . . . . . . . . . . . . . . . . EX-AR . . . . . . . . . . . . . . . . . . . . . . . . EX-AR141 . . . . . . . . . . . . . . . . . . . . . EX-AR16 . . . . . . . . . . . . . . . . . . . . . . EX-AR1613 . . . . . . . . . . . . . . . . . . . . EX-AR182 . . . . . . . . . . . . . . . . . . . . . EX-AR20 . . . . . . . . . . . . . . . . . . . . . . EX-AR230 . . . . . . . . . . . . . . . . . . . . . EX-AR30 . . . . . . . . . . . . . . . . . . . . . . EX-AR400 . . . . . . . . . . . . . . . . . . . . . EX-AR50 . . . . . . . . . . . . . . . . . . . . . . EX-AR800 . . . . . . . . . . . . . . . . . . . . . EX-AR830 . . . . . . . . . . . . . . . . . . . . . EX-CR . . . . . . . . . . . . . . . . . . . . . . . . EX-N15 . . . . . . . . . . . . . . . . . . . . . . . EX-Q . . . . . . . . . . . . . . . . . . . . . . . . . EX-Q400 . . . . . . . . . . . . . . . . . . . . . . EX-Q62 . . . . . . . . . . . . . . . . . . . . . . . EX-Q800 . . . . . . . . . . . . . . . . . . . . . . EX-XR3 . . . . . . . . . . . . . . . . . . . . . . . EXA-AR . . . . . . . . . . . . . . . . . . . . . . . EXA-AR20 . . . . . . . . . . . . . . . . . . . . . EXA-AR62 . . . . . . . . . . . . . . . . . . . . . EXA-N . . . . . . . . . . . . . . . . . . . . . . . . EXA-Q . . . . . . . . . . . . . . . . . . . . . . . . EXD-AR-3 . . . . . . . . . . . . . . . . . . . . . EXD-AR30-3 . . . . . . . . . . . . . . . . . . . EXD-Q-3 . . . . . . . . . . . . . . . . . . . . . . EXH-AR3 . . . . . . . . . . . . . . . . . . . . . . EXH-AR33 . . . . . . . . . . . . . . . . . . . . . 10 10 10 10 61 61 61 62 61 60 60 61 61 63 61 61 62 63 62 62 62 62 61 61 60 61 63 62 61 61 62 61 61 INDEX EXH-AR7 . . . . . . . . . . . . . . . . . . . . . . 61 F FR-01 . . . . . . . . . . . . . . . . . . . . . . . . . FRL91-22CGA3-BB79 . . . . . . . . . . . . FRL91-23CGG3-BB79 . . . . . . . . . . . . FRL91-21CGG3-BB77 . . . . . . . . . . . . FRL91-27CGG3-BB77 . . . . . . . . . . . . FRN91-11BB . . . . . . . . . . . . . . . . . . . FRN91-12BB . . . . . . . . . . . . . . . . . . . FRN91-13BB . . . . . . . . . . . . . . . . . . . FRN91-14BB . . . . . . . . . . . . . . . . . . . FRN91-15BB . . . . . . . . . . . . . . . . . . . FRN91-16BB . . . . . . . . . . . . . . . . . . . FRN91-17BB . . . . . . . . . . . . . . . . . . . FRN91-18BB . . . . . . . . . . . . . . . . . . . FRN91-21BB . . . . . . . . . . . . . . . . . . . FRN91-22BB . . . . . . . . . . . . . . . . . . . FRN91-23BB . . . . . . . . . . . . . . . . . . . FRN91-24BB . . . . . . . . . . . . . . . . . . . FRN91-25BB . . . . . . . . . . . . . . . . . . . FRN91-26BB . . . . . . . . . . . . . . . . . . . FRN91-27BB . . . . . . . . . . . . . . . . . . . FRN91-28BB . . . . . . . . . . . . . . . . . . . 160 160 160 160 160 159 159 159 159 159 159 159 159 159 159 159 159 159 159 159 159 G GKBA10L7 . . . . . . . . . . . . . . . . . . . . . GKBA14L6 . . . . . . . . . . . . . . . . . . . . . GKBA14L7 . . . . . . . . . . . . . . . . . . . . . GKBA16L6 . . . . . . . . . . . . . . . . . . . . . GKBA16L7 . . . . . . . . . . . . . . . . . . . . . GKBA1L7 . . . . . . . . . . . . . . . . . . . . . . GKBA1L8-F11 . . . . . . . . . . . . . . . . . . GKBA1LX . . . . . . . . . . . . . . . . . . . . . GKBA2L6 . . . . . . . . . . . . . . . . . . . . . . GKBA30LX . . . . . . . . . . . . . . . . . . . . GKBA36LX . . . . . . . . . . . . . . . . . . . . GKBA3L6 . . . . . . . . . . . . . . . . . . . . . . GKBA3L7 . . . . . . . . . . . . . . . . . . . . . . GKBA6LX . . . . . . . . . . . . . . . . . . . . . GKBB14L6 . . . . . . . . . . . . . . . . . . . . . GKBB3L7 . . . . . . . . . . . . . . . . . . . . . . GKBB6L7 . . . . . . . . . . . . . . . . . . . . . . GKBC14L7 . . . . . . . . . . . . . . . . . . . . . GKBC1L6 . . . . . . . . . . . . . . . . . . . . . . GKBC1L7 . . . . . . . . . . . . . . . . . . . . . . GKBC1LX . . . . . . . . . . . . . . . . . . . . . GKBC2LX . . . . . . . . . . . . . . . . . . . . . GKBC30LX . . . . . . . . . . . . . . . . . . . . GKBC36LX . . . . . . . . . . . . . . . . . . . . GKBC6LX . . . . . . . . . . . . . . . . . . . . . GKCA10L6 . . . . . . . . . . . . . . . . . . . . . GKCA14L6 . . . . . . . . . . . . . . . . . . . . . GKCA14L7 . . . . . . . . . . . . . . . . . . . . . GKCA14L9 . . . . . . . . . . . . . . . . . . . . . GKCA14M6 . . . . . . . . . . . . . . . . . . . . 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 GKCA14P6 . . . . . . . . . . . . . . . . . . . . GKCA1L6 . . . . . . . . . . . . . . . . . . . . . . GKCA1L7 . . . . . . . . . . . . . . . . . . . . . . GKCA1LX . . . . . . . . . . . . . . . . . . . . . GKCA1P7 . . . . . . . . . . . . . . . . . . . . . GKCA30LX . . . . . . . . . . . . . . . . . . . . GKCA36LX . . . . . . . . . . . . . . . . . . . . GKCA6LX . . . . . . . . . . . . . . . . . . . . . GKCC1LX . . . . . . . . . . . . . . . . . . . . . GKCC30LX . . . . . . . . . . . . . . . . . . . . GKCC36LX . . . . . . . . . . . . . . . . . . . . GKCC6LX . . . . . . . . . . . . . . . . . . . . . GKDA14L7 . . . . . . . . . . . . . . . . . . . . . GKDA14P7 . . . . . . . . . . . . . . . . . . . . GKEA1LX . . . . . . . . . . . . . . . . . . . . . . GKEA3LX . . . . . . . . . . . . . . . . . . . . . . GKEA6LX . . . . . . . . . . . . . . . . . . . . . . GKEC1LX . . . . . . . . . . . . . . . . . . . . . . GKEC3LX . . . . . . . . . . . . . . . . . . . . . . GKEC6LX . . . . . . . . . . . . . . . . . . . . . . GKLE36PXA2 . . . . . . . . . . . . . . . . . . GKLE36PXA4 . . . . . . . . . . . . . . . . . . GKLE36PXS2 . . . . . . . . . . . . . . . . . . GKLE36PXS4 . . . . . . . . . . . . . . . . . . GKLE3LXA2 . . . . . . . . . . . . . . . . . . . . GKLE3PXA2 . . . . . . . . . . . . . . . . . . . GKLE3PXA4 . . . . . . . . . . . . . . . . . . . GKLE3PXS2 . . . . . . . . . . . . . . . . . . . GKLE3PXS4 . . . . . . . . . . . . . . . . . . . GKLE40LXA2 . . . . . . . . . . . . . . . . . . . GKLE46LXA2 . . . . . . . . . . . . . . . . . . . GKLG1PXA2 . . . . . . . . . . . . . . . . . . . GKLG1PXA4 . . . . . . . . . . . . . . . . . . . GKLG1PXS2 . . . . . . . . . . . . . . . . . . . GKLG1PXS4 . . . . . . . . . . . . . . . . . . . GKLG36PXA2 . . . . . . . . . . . . . . . . . . GKLG36PXA4 . . . . . . . . . . . . . . . . . . GKLG36PXS2 . . . . . . . . . . . . . . . . . . GKLG36PXS4 . . . . . . . . . . . . . . . . . . GKLG3PXS2 . . . . . . . . . . . . . . . . . . . GKLG44PXB2 . . . . . . . . . . . . . . . . . . GKM Series . . . . . . . . . . . . . . . . . . . . GKMA17 . . . . . . . . . . . . . . . . . . . . . . GKMA19 . . . . . . . . . . . . . . . . . . . . . . GKMA23 . . . . . . . . . . . . . . . . . . . . . . GKMA26 . . . . . . . . . . . . . . . . . . . . . . GKMA27 . . . . . . . . . . . . . . . . . . . . . . GKMA29 . . . . . . . . . . . . . . . . . . . . . . GKMA33 . . . . . . . . . . . . . . . . . . . . . . GKMA36 . . . . . . . . . . . . . . . . . . . . . . GKMA37 . . . . . . . . . . . . . . . . . . . . . . GKMA39 . . . . . . . . . . . . . . . . . . . . . . GKMB13 . . . . . . . . . . . . . . . . . . . . . . GKMB16 . . . . . . . . . . . . . . . . . . . . . . GKMB17 . . . . . . . . . . . . . . . . . . . . . . GKMB19 . . . . . . . . . . . . . . . . . . . . . . 88 88 88 88 88 88 88 88 88 88 88 88 88 88 94 94 94 94 94 94 91 91 91 91 90 91 91 91 91 90 90 91 91 91 91 91 91 91 91 91 91 82 83 83 83 83 83 83 83 83 83 83 83 83 83 83 www.honeywell.com/sensing GKMB23 . . . . . . . . . . . . . . . . . . . . . . GKMB26 . . . . . . . . . . . . . . . . . . . . . . GKMB27 . . . . . . . . . . . . . . . . . . . . . . GKMB29 . . . . . . . . . . . . . . . . . . . . . . GKMB33 . . . . . . . . . . . . . . . . . . . . . . GKMB36 . . . . . . . . . . . . . . . . . . . . . . GKMB37 . . . . . . . . . . . . . . . . . . . . . . GKMB39 . . . . . . . . . . . . . . . . . . . . . . GKMC03 . . . . . . . . . . . . . . . . . . . . . . GKMC06 . . . . . . . . . . . . . . . . . . . . . . GKMC07 . . . . . . . . . . . . . . . . . . . . . . GKMC09 . . . . . . . . . . . . . . . . . . . . . . GKMD03 . . . . . . . . . . . . . . . . . . . . . . GKMD07 . . . . . . . . . . . . . . . . . . . . . . GKMD09 . . . . . . . . . . . . . . . . . . . . . . GKMF03 . . . . . . . . . . . . . . . . . . . . . . . GKMF06 . . . . . . . . . . . . . . . . . . . . . . . GKMF07 . . . . . . . . . . . . . . . . . . . . . . . GKMF09 . . . . . . . . . . . . . . . . . . . . . . . GKNC12l . . . . . . . . . . . . . . . . . . . . . . GKNC33L . . . . . . . . . . . . . . . . . . . . . . GKNC4L . . . . . . . . . . . . . . . . . . . . . . . GKNC6L . . . . . . . . . . . . . . . . . . . . . . . GKRE36MXA2 . . . . . . . . . . . . . . . . . . GKRE36MXA4 . . . . . . . . . . . . . . . . . . GKRE36MXS2 . . . . . . . . . . . . . . . . . . GKRE3MXA2 . . . . . . . . . . . . . . . . . . . GKRE3MXA4 . . . . . . . . . . . . . . . . . . . GKRE3MXS2 . . . . . . . . . . . . . . . . . . . GKRE3MXS4 . . . . . . . . . . . . . . . . . . . GKRE40LXA2 . . . . . . . . . . . . . . . . . . GKRE46LXA2 . . . . . . . . . . . . . . . . . . GKRG1MXA2 . . . . . . . . . . . . . . . . . . . GKRG1MXA4 . . . . . . . . . . . . . . . . . . . GKRG1MXS2 . . . . . . . . . . . . . . . . . . . GKRG1MXS4 . . . . . . . . . . . . . . . . . . . GKRG36MXA2 . . . . . . . . . . . . . . . . . . GKRG36MXA4 . . . . . . . . . . . . . . . . . . GKRG36MXS2 . . . . . . . . . . . . . . . . . . GKRG36MXS4 . . . . . . . . . . . . . . . . . . GKRG3MXA2 . . . . . . . . . . . . . . . . . . . GKZ51M . . . . . . . . . . . . . . . . . . . . . . GKZ52M . . . . . . . . . . . . . . . . . . . . . . GKZ56 . . . . . . . . . . . . . . . . . . . . . . . . GKZ57 . . . . . . . . . . . . . . . . . . . . . . . . GKZ58 . . . . . . . . . . . . . . . . . . . . . . . . GKZ59 . . . . . . . . . . . . . . . . . . . . . . . . GKZ71 . . . . . . . . . . . . . . . . . . . . . . . . GKZ72 . . . . . . . . . . . . . . . . . . . . . . . . GKZ73 . . . . . . . . . . . . . . . . . . . . . . . . GKZ74 . . . . . . . . . . . . . . . . . . . . . . . . GLAA01A . . . . . . . . . . . . . . . . . . . . . . GLAA01A1A . . . . . . . . . . . . . . . . . . . GLAA01A1B . . . . . . . . . . . . . . . . . . . GLAA01A2A . . . . . . . . . . . . . . . . . . . GLAA01A2B . . . . . . . . . . . . . . . . . . . 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 97 97 97 97 91 91 91 91 91 91 91 90 90 91 91 91 91 91 91 91 91 91 83 83 92 92 92 92 92 92 92 92 15 15 15 15 15 205 INDEX GLAA01A4J . . . . . . . . . . . . . . . . . . . . GLAA01B . . . . . . . . . . . . . . . . . . . . . . GLAA01C . . . . . . . . . . . . . . . . . . . . . . GLAA01D . . . . . . . . . . . . . . . . . . . . . . GLAA01E7B . . . . . . . . . . . . . . . . . . . . GLAA01E7D . . . . . . . . . . . . . . . . . . . . GLAA01K8B . . . . . . . . . . . . . . . . . . . GLAA01K8C . . . . . . . . . . . . . . . . . . . GLAA20A . . . . . . . . . . . . . . . . . . . . . . GLAA20A1A . . . . . . . . . . . . . . . . . . . GLAA20A1B . . . . . . . . . . . . . . . . . . . GLAA20A2A . . . . . . . . . . . . . . . . . . . GLAA20A2B . . . . . . . . . . . . . . . . . . . GLAA20A4J . . . . . . . . . . . . . . . . . . . . GLAA20B . . . . . . . . . . . . . . . . . . . . . . GLAA20C . . . . . . . . . . . . . . . . . . . . . . GLAA20D . . . . . . . . . . . . . . . . . . . . . . GLAA20K8C . . . . . . . . . . . . . . . . . . . GLAB01A . . . . . . . . . . . . . . . . . . . . . . GLAB01A1A . . . . . . . . . . . . . . . . . . . GLAB01A1B . . . . . . . . . . . . . . . . . . . GLAB01A2A . . . . . . . . . . . . . . . . . . . GLAB01A2B . . . . . . . . . . . . . . . . . . . GLAB01A4J . . . . . . . . . . . . . . . . . . . . GLAB01B . . . . . . . . . . . . . . . . . . . . . . GLAB01C . . . . . . . . . . . . . . . . . . . . . . GLAB01D . . . . . . . . . . . . . . . . . . . . . . GLAB01E7B . . . . . . . . . . . . . . . . . . . . GLAB01K8B . . . . . . . . . . . . . . . . . . . GLAB01K8C . . . . . . . . . . . . . . . . . . . GLAB20A1A . . . . . . . . . . . . . . . . . . . GLAB20A1B . . . . . . . . . . . . . . . . . . . GLAB20A2A . . . . . . . . . . . . . . . . . . . GLAB20A2B . . . . . . . . . . . . . . . . . . . GLAB20A4J . . . . . . . . . . . . . . . . . . . . GLAB20B . . . . . . . . . . . . . . . . . . . . . . GLAB20C . . . . . . . . . . . . . . . . . . . . . . GLAB20D . . . . . . . . . . . . . . . . . . . . . . GLAB20E7B . . . . . . . . . . . . . . . . . . . . GLAC01A1A . . . . . . . . . . . . . . . . . . . GLAC01A1B . . . . . . . . . . . . . . . . . . . GLAC01A2A . . . . . . . . . . . . . . . . . . . GLAC01A2B . . . . . . . . . . . . . . . . . . . GLAC01A4J . . . . . . . . . . . . . . . . . . . . GLAC01B . . . . . . . . . . . . . . . . . . . . . . GLAC01C . . . . . . . . . . . . . . . . . . . . . . GLAC01D . . . . . . . . . . . . . . . . . . . . . . GLAC01E7B . . . . . . . . . . . . . . . . . . . . GLAC20A1A . . . . . . . . . . . . . . . . . . . GLAC20A1B . . . . . . . . . . . . . . . . . . . GLAC20A2B . . . . . . . . . . . . . . . . . . . GLAC20B . . . . . . . . . . . . . . . . . . . . . . GLAC20C . . . . . . . . . . . . . . . . . . . . . . GLAC20D . . . . . . . . . . . . . . . . . . . . . . GLAC20E7B . . . . . . . . . . . . . . . . . . . . GLCA01A1A . . . . . . . . . . . . . . . . . . . 206 15 15 15 15 16 16 16 16 15 15 15 15 15 15 15 15 15 16 15 15 15 15 15 15 15 15 15 16 16 16 15 15 15 15 15 15 15 15 16 15 15 15 15 15 15 15 15 16 15 15 15 15 15 15 16 16 GLCA01A1B . . . . . . . . . . . . . . . . . . . GLCA01A2A . . . . . . . . . . . . . . . . . . . GLCA01A2B . . . . . . . . . . . . . . . . . . . GLCA01A4J . . . . . . . . . . . . . . . . . . . . GLCA01B . . . . . . . . . . . . . . . . . . . . . . GLCA01C . . . . . . . . . . . . . . . . . . . . . . GLCA01D . . . . . . . . . . . . . . . . . . . . . . GLCA01E7B . . . . . . . . . . . . . . . . . . . . GLCA01K8A . . . . . . . . . . . . . . . . . . . GLCB01A1A . . . . . . . . . . . . . . . . . . . GLCB01A1B . . . . . . . . . . . . . . . . . . . GLCB01A2A . . . . . . . . . . . . . . . . . . . GLCB01A2B . . . . . . . . . . . . . . . . . . . GLCB01A4J . . . . . . . . . . . . . . . . . . . . GLCB01B . . . . . . . . . . . . . . . . . . . . . . GLCB01C . . . . . . . . . . . . . . . . . . . . . . GLCB01D . . . . . . . . . . . . . . . . . . . . . . GLCB01E7B . . . . . . . . . . . . . . . . . . . . GLCB01K8A . . . . . . . . . . . . . . . . . . . GLCC01A1B . . . . . . . . . . . . . . . . . . . GLCC01A2B . . . . . . . . . . . . . . . . . . . GLCC01B . . . . . . . . . . . . . . . . . . . . . . GLCC01C . . . . . . . . . . . . . . . . . . . . . . GLCC01D . . . . . . . . . . . . . . . . . . . . . . GLCC01E7B . . . . . . . . . . . . . . . . . . . . GLDA01A1A . . . . . . . . . . . . . . . . . . . GLDA01A1B . . . . . . . . . . . . . . . . . . . GLDA01A2A . . . . . . . . . . . . . . . . . . . GLDA01A2B . . . . . . . . . . . . . . . . . . . GLDA01A4J . . . . . . . . . . . . . . . . . . . . GLDA01B . . . . . . . . . . . . . . . . . . . . . . GLDA01C . . . . . . . . . . . . . . . . . . . . . . GLDA01D . . . . . . . . . . . . . . . . . . . . . . GLDA01E7B . . . . . . . . . . . . . . . . . . . . GLDB01A1A . . . . . . . . . . . . . . . . . . . GLDB01A1B . . . . . . . . . . . . . . . . . . . GLDB01A2A . . . . . . . . . . . . . . . . . . . GLDB01A2B . . . . . . . . . . . . . . . . . . . GLDB01A4J . . . . . . . . . . . . . . . . . . . . GLDB01B . . . . . . . . . . . . . . . . . . . . . . GLDB01C . . . . . . . . . . . . . . . . . . . . . . GLDB01D . . . . . . . . . . . . . . . . . . . . . . GLDB01E7B . . . . . . . . . . . . . . . . . . . . GLDC01A1B . . . . . . . . . . . . . . . . . . . GLDC01A2B . . . . . . . . . . . . . . . . . . . GLDC01B . . . . . . . . . . . . . . . . . . . . . . GLDC01C . . . . . . . . . . . . . . . . . . . . . . GLDC01D . . . . . . . . . . . . . . . . . . . . . . GLDC01E7B . . . . . . . . . . . . . . . . . . . . GLEA01A1A . . . . . . . . . . . . . . . . . . . . GLEA01A1B . . . . . . . . . . . . . . . . . . . . GLEA01A2A . . . . . . . . . . . . . . . . . . . . GLEA01A2B . . . . . . . . . . . . . . . . . . . . GLEA01A5A . . . . . . . . . . . . . . . . . . . . GLEA01B . . . . . . . . . . . . . . . . . . . . . . GLEA01C . . . . . . . . . . . . . . . . . . . . . . 16 17 17 17 17 17 17 17 17 16 16 17 17 17 17 17 17 17 17 16 17 17 17 17 17 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 19 19 19 19 19 www.honeywell.com/sensing GLEA01D . . . . . . . . . . . . . . . . . . . . . . GLEA01E7B . . . . . . . . . . . . . . . . . . . . GLEA24A1B . . . . . . . . . . . . . . . . . . . . GLEA24A2A . . . . . . . . . . . . . . . . . . . . GLEA24B . . . . . . . . . . . . . . . . . . . . . . GLEA24C . . . . . . . . . . . . . . . . . . . . . . GLEA24D . . . . . . . . . . . . . . . . . . . . . . GLEA24E7B . . . . . . . . . . . . . . . . . . . . GLEB01A1A . . . . . . . . . . . . . . . . . . . . GLEB01A1B . . . . . . . . . . . . . . . . . . . . GLEB01A2A . . . . . . . . . . . . . . . . . . . . GLEB01A2B . . . . . . . . . . . . . . . . . . . . GLEB01A4J . . . . . . . . . . . . . . . . . . . . GLEB01A5A . . . . . . . . . . . . . . . . . . . . GLEB01B . . . . . . . . . . . . . . . . . . . . . . GLEB01C . . . . . . . . . . . . . . . . . . . . . . GLEB01D . . . . . . . . . . . . . . . . . . . . . . GLEB01E7B . . . . . . . . . . . . . . . . . . . . GLEB24A1A . . . . . . . . . . . . . . . . . . . . GLEB24A1B . . . . . . . . . . . . . . . . . . . . GLEB24A2B . . . . . . . . . . . . . . . . . . . . GLEB24A4J . . . . . . . . . . . . . . . . . . . . GLEB24B . . . . . . . . . . . . . . . . . . . . . . GLEB24C . . . . . . . . . . . . . . . . . . . . . . GLEB24D . . . . . . . . . . . . . . . . . . . . . . GLEB24E7B . . . . . . . . . . . . . . . . . . . . GLEC01A1B . . . . . . . . . . . . . . . . . . . . GLEC01D . . . . . . . . . . . . . . . . . . . . . . GLEC24C . . . . . . . . . . . . . . . . . . . . . . GLEC24D . . . . . . . . . . . . . . . . . . . . . . GLL EN 50047 . . . . . . . . . . . . . . . . . . GLZ51A . . . . . . . . . . . . . . . . . . . . . . . GLZ51B . . . . . . . . . . . . . . . . . . . . . . . GLZ52A . . . . . . . . . . . . . . . . . . . . . . . GLZ52B . . . . . . . . . . . . . . . . . . . . . . . GLZ54J . . . . . . . . . . . . . . . . . . . . . . . GLZ55B . . . . . . . . . . . . . . . . . . . . . . . GSCA01S1 . . . . . . . . . . . . . . . . . . . . GSCA01S2 . . . . . . . . . . . . . . . . . . . . GSCA01S3 . . . . . . . . . . . . . . . . . . . . GSCA03S1 . . . . . . . . . . . . . . . . . . . . GSCA03S2 . . . . . . . . . . . . . . . . . . . . GSCA03S3 . . . . . . . . . . . . . . . . . . . . GSCA06S1 . . . . . . . . . . . . . . . . . . . . GSCA06S2 . . . . . . . . . . . . . . . . . . . . GSCA06S3 . . . . . . . . . . . . . . . . . . . . GSCB36S2 . . . . . . . . . . . . . . . . . . . . GSCB36S3 . . . . . . . . . . . . . . . . . . . . GSCC36S1 . . . . . . . . . . . . . . . . . . . . GSDA03S1 . . . . . . . . . . . . . . . . . . . . GSDA03S2 . . . . . . . . . . . . . . . . . . . . GSDA03S3 . . . . . . . . . . . . . . . . . . . . GSDA06S1 . . . . . . . . . . . . . . . . . . . . GSDA06S2 . . . . . . . . . . . . . . . . . . . . GSDA06S3 . . . . . . . . . . . . . . . . . . . . GSDB03S1 . . . . . . . . . . . . . . . . . . . . 19 19 18 19 19 19 19 19 18 18 19 19 19 19 19 19 19 19 18 18 19 19 19 19 19 19 18 19 19 19 20 72 72 72 72 72 72 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 INDEX GSDB03S2 . . . . . . . . . . . . . . . . . . . . 85 GSDB03S3 . . . . . . . . . . . . . . . . . . . . 85 GSDB06S1 . . . . . . . . . . . . . . . . . . . . 85 GSDB06S2 . . . . . . . . . . . . . . . . . . . . 85 GSDB06S3 . . . . . . . . . . . . . . . . . . . . 85 GSDC01S1 . . . . . . . . . . . . . . . . . . . . 85 GSDC01S2 . . . . . . . . . . . . . . . . . . . . 85 GSDC01S3 . . . . . . . . . . . . . . . . . . . . 85 GSEA44S1 . . . . . . . . . . . . . . . . . . . . . 86 GSEA44S2 . . . . . . . . . . . . . . . . . . . . . 86 GSEA44S3 . . . . . . . . . . . . . . . . . . . . . 86 GSEA46S1 . . . . . . . . . . . . . . . . . . . . . 86 GSEC41S1 . . . . . . . . . . . . . . . . . . . . . 86 GSS Series . . . . . . . . . . . . . . . . . . . . 84 GXE Series . . . . . . . . . . . . . . . . . . . . . 59 GXE51A1B . . . . . . . . . . . . . . . . . . . . . 59 GXE51B . . . . . . . . . . . . . . . . . . . . . . . 59 GXE51C . . . . . . . . . . . . . . . . . . . . . . . 59 H HRSR-01 . . . . . . . . . . . . . . . . . . . . . 162 J JE-1 . . . . . . . . . . . . . . . . . . . . . . . . . 123 JE-4 . . . . . . . . . . . . . . . . . . . . . . . . . 123 JE-5 . . . . . . . . . . . . . . . . . . . . . . . . . 123 JM-1 . . . . . . . . . . . . . . . . . . . . . . . . 125 JM-5 . . . . . . . . . . . . . . . . . . . . . . . . 125 JS-151 . . . . . . . . . . . . . . . . . . . . . . . 127 JS-254 . . . . . . . . . . . . . . . . . . . . . . . 127 L Levers . . . . . . . . . . . . . . . . . . . . . . . . LS2A4K . . . . . . . . . . . . . . . . . . . . . . . LS2A4L . . . . . . . . . . . . . . . . . . . . . . . LS2D4K . . . . . . . . . . . . . . . . . . . . . . . LS2D4L . . . . . . . . . . . . . . . . . . . . . . . LS2E4K . . . . . . . . . . . . . . . . . . . . . . . LS2E4L . . . . . . . . . . . . . . . . . . . . . . . LS2F4K . . . . . . . . . . . . . . . . . . . . . . . LS2F4L . . . . . . . . . . . . . . . . . . . . . . . LS2H4K . . . . . . . . . . . . . . . . . . . . . . . LS2H4L . . . . . . . . . . . . . . . . . . . . . . . LS2M4N . . . . . . . . . . . . . . . . . . . . . . LS2Z51A . . . . . . . . . . . . . . . . . . . . . . LS2Z51B . . . . . . . . . . . . . . . . . . . . . . LS2Z52A . . . . . . . . . . . . . . . . . . . . . . LS2Z52B . . . . . . . . . . . . . . . . . . . . . . LS2Z54N . . . . . . . . . . . . . . . . . . . . . . LS4A1A . . . . . . . . . . . . . . . . . . . . . . . LS4A2B . . . . . . . . . . . . . . . . . . . . . . . LS4A3K . . . . . . . . . . . . . . . . . . . . . . . LS4M2D . . . . . . . . . . . . . . . . . . . . . . LSA1A . . . . . . . . . . . . . . . . . . . . . . . . LSA1E . . . . . . . . . . . . . . . . . . . . . . . . LSA2B . . . . . . . . . . . . . . . . . . . . . . . . 71 55 55 55 55 55 55 55 55 55 55 55 73 73 73 73 73 49 49 49 49 49 49 49 LSA3K . . . . . . . . . . . . . . . . . . . . . . . . LSA4L . . . . . . . . . . . . . . . . . . . . . . . . LSA6B . . . . . . . . . . . . . . . . . . . . . . . . LSA6S . . . . . . . . . . . . . . . . . . . . . . . . LSC1A . . . . . . . . . . . . . . . . . . . . . . . . LSC1E . . . . . . . . . . . . . . . . . . . . . . . . LSC3K . . . . . . . . . . . . . . . . . . . . . . . . LSC6B . . . . . . . . . . . . . . . . . . . . . . . . LSC6S . . . . . . . . . . . . . . . . . . . . . . . . LSC7L . . . . . . . . . . . . . . . . . . . . . . . . LSD1A . . . . . . . . . . . . . . . . . . . . . . . . LSD1E . . . . . . . . . . . . . . . . . . . . . . . . LSD3K . . . . . . . . . . . . . . . . . . . . . . . . LSD6B . . . . . . . . . . . . . . . . . . . . . . . . LSD6S . . . . . . . . . . . . . . . . . . . . . . . . LSD7L . . . . . . . . . . . . . . . . . . . . . . . . LSE1A . . . . . . . . . . . . . . . . . . . . . . . . LSE1E . . . . . . . . . . . . . . . . . . . . . . . . LSE3K . . . . . . . . . . . . . . . . . . . . . . . . LSE6B . . . . . . . . . . . . . . . . . . . . . . . . LSE6S . . . . . . . . . . . . . . . . . . . . . . . . LSE7L . . . . . . . . . . . . . . . . . . . . . . . . LSF1A . . . . . . . . . . . . . . . . . . . . . . . . LSF1E . . . . . . . . . . . . . . . . . . . . . . . . LSF3K . . . . . . . . . . . . . . . . . . . . . . . . LSF6B . . . . . . . . . . . . . . . . . . . . . . . . LSF6S . . . . . . . . . . . . . . . . . . . . . . . . LSF7L . . . . . . . . . . . . . . . . . . . . . . . . LSG1A . . . . . . . . . . . . . . . . . . . . . . . . LSG1E . . . . . . . . . . . . . . . . . . . . . . . . LSG3K . . . . . . . . . . . . . . . . . . . . . . . . LSG6B . . . . . . . . . . . . . . . . . . . . . . . . LSG6S . . . . . . . . . . . . . . . . . . . . . . . . LSG7L . . . . . . . . . . . . . . . . . . . . . . . . LSH1A . . . . . . . . . . . . . . . . . . . . . . . . LSH1E . . . . . . . . . . . . . . . . . . . . . . . . LSH2B . . . . . . . . . . . . . . . . . . . . . . . . LSH3K . . . . . . . . . . . . . . . . . . . . . . . . LSH4L . . . . . . . . . . . . . . . . . . . . . . . . LSH6B . . . . . . . . . . . . . . . . . . . . . . . . LSH6S . . . . . . . . . . . . . . . . . . . . . . . . LSJ1A-7A . . . . . . . . . . . . . . . . . . . . . LSJ1A-7M . . . . . . . . . . . . . . . . . . . . . LSJ1A-7N . . . . . . . . . . . . . . . . . . . . . LSJ3K-7A . . . . . . . . . . . . . . . . . . . . . LSJ3K-7M . . . . . . . . . . . . . . . . . . . . . LSJ3K-7N . . . . . . . . . . . . . . . . . . . . . LSJ6B-7A . . . . . . . . . . . . . . . . . . . . . LSJ6B-7M . . . . . . . . . . . . . . . . . . . . . LSJ6B-7N . . . . . . . . . . . . . . . . . . . . . LSJ7L-7A . . . . . . . . . . . . . . . . . . . . . LSJ7L-7M . . . . . . . . . . . . . . . . . . . . . LSJ7L-7N . . . . . . . . . . . . . . . . . . . . . LSK1A-8A . . . . . . . . . . . . . . . . . . . . . LSK1A-8C . . . . . . . . . . . . . . . . . . . . . LSK3K-8A . . . . . . . . . . . . . . . . . . . . . 49 49 49 49 50 50 50 50 50 50 50 50 50 50 50 50 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 49 49 49 49 49 49 49 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 www.honeywell.com/sensing LSK3K-8C . . . . . . . . . . . . . . . . . . . . . LSK6B-8A . . . . . . . . . . . . . . . . . . . . . LSK6B-8C . . . . . . . . . . . . . . . . . . . . . LSK7L-8A . . . . . . . . . . . . . . . . . . . . . LSK7L-8C . . . . . . . . . . . . . . . . . . . . . LSL2C . . . . . . . . . . . . . . . . . . . . . . . . LSL4M . . . . . . . . . . . . . . . . . . . . . . . . LSL6C . . . . . . . . . . . . . . . . . . . . . . . . LSL7M . . . . . . . . . . . . . . . . . . . . . . . . LSM2D . . . . . . . . . . . . . . . . . . . . . . . LSM4N . . . . . . . . . . . . . . . . . . . . . . . LSM6D . . . . . . . . . . . . . . . . . . . . . . . LSM7N . . . . . . . . . . . . . . . . . . . . . . . LSN1A . . . . . . . . . . . . . . . . . . . . . . . . LSN3K . . . . . . . . . . . . . . . . . . . . . . . . LSN6B . . . . . . . . . . . . . . . . . . . . . . . . LSN7L . . . . . . . . . . . . . . . . . . . . . . . . LSP1A . . . . . . . . . . . . . . . . . . . . . . . . LSP1E . . . . . . . . . . . . . . . . . . . . . . . . LSP2B . . . . . . . . . . . . . . . . . . . . . . . . LSP3K . . . . . . . . . . . . . . . . . . . . . . . . LSP4L . . . . . . . . . . . . . . . . . . . . . . . . LSP6B . . . . . . . . . . . . . . . . . . . . . . . . LSP6S . . . . . . . . . . . . . . . . . . . . . . . . LSR1A . . . . . . . . . . . . . . . . . . . . . . . . LSR1E . . . . . . . . . . . . . . . . . . . . . . . . LSR2B . . . . . . . . . . . . . . . . . . . . . . . . LSR3K . . . . . . . . . . . . . . . . . . . . . . . . LSR4L . . . . . . . . . . . . . . . . . . . . . . . . LSR6B . . . . . . . . . . . . . . . . . . . . . . . . LSR6S . . . . . . . . . . . . . . . . . . . . . . . . LSU1A . . . . . . . . . . . . . . . . . . . . . . . . LSU1E . . . . . . . . . . . . . . . . . . . . . . . . LSU2B . . . . . . . . . . . . . . . . . . . . . . . . LSU3K . . . . . . . . . . . . . . . . . . . . . . . . LSU4L . . . . . . . . . . . . . . . . . . . . . . . . LSU6B . . . . . . . . . . . . . . . . . . . . . . . . LSU6S . . . . . . . . . . . . . . . . . . . . . . . . LSV1A . . . . . . . . . . . . . . . . . . . . . . . . LSV1E . . . . . . . . . . . . . . . . . . . . . . . . LSV3K . . . . . . . . . . . . . . . . . . . . . . . . LSV6B . . . . . . . . . . . . . . . . . . . . . . . . LSV6S . . . . . . . . . . . . . . . . . . . . . . . . LSV7L . . . . . . . . . . . . . . . . . . . . . . . . LSW1A . . . . . . . . . . . . . . . . . . . . . . . LSW1E . . . . . . . . . . . . . . . . . . . . . . . LSW3K . . . . . . . . . . . . . . . . . . . . . . . LSW6B . . . . . . . . . . . . . . . . . . . . . . . LSW6S . . . . . . . . . . . . . . . . . . . . . . . LSW7L . . . . . . . . . . . . . . . . . . . . . . . LSX4A3K . . . . . . . . . . . . . . . . . . . . . . LSX4A4L . . . . . . . . . . . . . . . . . . . . . . LSX4C3K . . . . . . . . . . . . . . . . . . . . . . LSX4D3K . . . . . . . . . . . . . . . . . . . . . . LSX4M4N . . . . . . . . . . . . . . . . . . . . . LSXA3E . . . . . . . . . . . . . . . . . . . . . . . 52 52 52 52 52 49 49 49 49 49 49 49 49 50 50 50 50 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 50 50 50 50 50 50 51 51 51 51 51 51 67 67 68 68 67 67 207 INDEX LSXA3K . . . . . . . . . . . . . . . . . . . . . . . LSXA4K . . . . . . . . . . . . . . . . . . . . . . . LSXA4L . . . . . . . . . . . . . . . . . . . . . . . LSXA7L . . . . . . . . . . . . . . . . . . . . . . . LSXB3K . . . . . . . . . . . . . . . . . . . . . . . LSXB4L . . . . . . . . . . . . . . . . . . . . . . . LSXC3K . . . . . . . . . . . . . . . . . . . . . . . LSXC4L . . . . . . . . . . . . . . . . . . . . . . . LSXD3K . . . . . . . . . . . . . . . . . . . . . . . LSXD4L . . . . . . . . . . . . . . . . . . . . . . . LSXE3K . . . . . . . . . . . . . . . . . . . . . . . LSXE4L . . . . . . . . . . . . . . . . . . . . . . . LSXF3K . . . . . . . . . . . . . . . . . . . . . . . LSXH3K . . . . . . . . . . . . . . . . . . . . . . . LSXH4L . . . . . . . . . . . . . . . . . . . . . . . LSXJ3K-7A . . . . . . . . . . . . . . . . . . . . LSXJ4L-7A . . . . . . . . . . . . . . . . . . . . LSXK3K-8A . . . . . . . . . . . . . . . . . . . . LSXM4N . . . . . . . . . . . . . . . . . . . . . . LSXN3K . . . . . . . . . . . . . . . . . . . . . . . LSXN4L . . . . . . . . . . . . . . . . . . . . . . . LSXN7L . . . . . . . . . . . . . . . . . . . . . . . LSXP3K . . . . . . . . . . . . . . . . . . . . . . . LSXR3K . . . . . . . . . . . . . . . . . . . . . . . LSXR4L . . . . . . . . . . . . . . . . . . . . . . . LSXV3K . . . . . . . . . . . . . . . . . . . . . . . LSY*C3KP-**FP . . . . . . . . . . . . . . . . LSY*C3KQ-**FP . . . . . . . . . . . . . . . . LSY*C4LX-**FP . . . . . . . . . . . . . . . . LSY*C7LR-**FP . . . . . . . . . . . . . . . . LSYAC3KP-FP . . . . . . . . . . . . . . . . . . LSYAC3KQ-FP . . . . . . . . . . . . . . . . . . LSYAC4LX-FP . . . . . . . . . . . . . . . . . . LSYAC7LR-FP . . . . . . . . . . . . . . . . . . LSYCC3KP-FP . . . . . . . . . . . . . . . . . . LSYCC3KQ-FP . . . . . . . . . . . . . . . . . . LSYCC4LX-FP . . . . . . . . . . . . . . . . . . LSYCC7LR-FP . . . . . . . . . . . . . . . . . . LSYDC3KP-FP . . . . . . . . . . . . . . . . . . LSYDC3KQ-FP . . . . . . . . . . . . . . . . . . LSYDC4LX-FP . . . . . . . . . . . . . . . . . . LSYDC7LR-FP . . . . . . . . . . . . . . . . . . LSYEC3KP-FP . . . . . . . . . . . . . . . . . . LSYEC3KQ-FP . . . . . . . . . . . . . . . . . . LSYEC4LX-FP . . . . . . . . . . . . . . . . . . LSYEC7LR-FP . . . . . . . . . . . . . . . . . . LSYLC4MX-FP . . . . . . . . . . . . . . . . . LSYLC7MR-FP . . . . . . . . . . . . . . . . . LSYMC4NX-FP . . . . . . . . . . . . . . . . . LSYMC7NR-FP . . . . . . . . . . . . . . . . . LSYPC3KP-FP . . . . . . . . . . . . . . . . . . LSYPC3KQ-FP . . . . . . . . . . . . . . . . . . LSYPC4LX-FP . . . . . . . . . . . . . . . . . . LSYPC7LR-FP . . . . . . . . . . . . . . . . . . LSYUC3KP-FP . . . . . . . . . . . . . . . . . . LSYUC3KQ-FP . . . . . . . . . . . . . . . . . . 208 67 67 67 67 67 67 68 68 68 68 69 69 69 67 67 69 69 69 67 67 67 67 67 67 67 68 54 54 54 54 53 53 53 53 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 53 53 53 53 53 53 LSZ51 . . . . . . . . . . . . . . . . . . . . . . . . LSZ51A . . . . . . . . . . . . . . . . . . . . . . . LSZ51B . . . . . . . . . . . . . . . . . . . . . . . LSZ51C . . . . . . . . . . . . . . . . . . . . . . . LSZ51D . . . . . . . . . . . . . . . . . . . . . . . LSZ51W . . . . . . . . . . . . . . . . . . . . . . LSZ51Y . . . . . . . . . . . . . . . . . . . . . . . LSZ52 . . . . . . . . . . . . . . . . . . . . . . . . LSZ52A . . . . . . . . . . . . . . . . . . . . . . . LSZ52B . . . . . . . . . . . . . . . . . . . . . . . LSZ52C . . . . . . . . . . . . . . . . . . . . . . . LSZ52D . . . . . . . . . . . . . . . . . . . . . . . LSZ52J . . . . . . . . . . . . . . . . . . . . . . . LSZ52K . . . . . . . . . . . . . . . . . . . . . . . LSZ52M . . . . . . . . . . . . . . . . . . . . . . . LSZ52N . . . . . . . . . . . . . . . . . . . . . . . LSZ52W . . . . . . . . . . . . . . . . . . . . . . LSZ52Y . . . . . . . . . . . . . . . . . . . . . . . LSZ53A . . . . . . . . . . . . . . . . . . . . . . . LSZ53B . . . . . . . . . . . . . . . . . . . . . . . LSZ53D . . . . . . . . . . . . . . . . . . . . . . . LSZ53E . . . . . . . . . . . . . . . . . . . . . . . LSZ53P . . . . . . . . . . . . . . . . . . . . . . . LSZ53S . . . . . . . . . . . . . . . . . . . . . . . LSZ53U . . . . . . . . . . . . . . . . . . . . . . . LSZ54 . . . . . . . . . . . . . . . . . . . . . . . . LSZ54M . . . . . . . . . . . . . . . . . . . . . . . LSZ54N . . . . . . . . . . . . . . . . . . . . . . . LSZ54R . . . . . . . . . . . . . . . . . . . . . . . LSZ54V . . . . . . . . . . . . . . . . . . . . . . . LSZ55 . . . . . . . . . . . . . . . . . . . . . . . . LSZ55A . . . . . . . . . . . . . . . . . . . . . . . LSZ55B . . . . . . . . . . . . . . . . . . . . . . . LSZ55C . . . . . . . . . . . . . . . . . . . . . . . LSZ55D . . . . . . . . . . . . . . . . . . . . . . . LSZ55W . . . . . . . . . . . . . . . . . . . . . . LSZ55Y . . . . . . . . . . . . . . . . . . . . . . . LSZ61 . . . . . . . . . . . . . . . . . . . . . . . . LSZ67AA . . . . . . . . . . . . . . . . . . . . . . LSZ68 . . . . . . . . . . . . . . . . . . . . . . . . 72 72 72 72 72 73 73 72 72 72 72 72 72 72 72 72 73 73 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 73 73 73 73 72 M MR93-12BBN . . . . . . . . . . . . . . . . . . MR93-121BK . . . . . . . . . . . . . . . . . . . MR93-122B3 . . . . . . . . . . . . . . . . . . . MR93-122BJ . . . . . . . . . . . . . . . . . . . MR93-124B3 . . . . . . . . . . . . . . . . . . . MR93-22BBN . . . . . . . . . . . . . . . . . . MR93-221B4 . . . . . . . . . . . . . . . . . . . MR93-222B3 . . . . . . . . . . . . . . . . . . . MR93-224B3 . . . . . . . . . . . . . . . . . . . MRS93-11BB . . . . . . . . . . . . . . . . . . MRS93-12BB . . . . . . . . . . . . . . . . . . MRS93-13BB . . . . . . . . . . . . . . . . . . MRS93-14BB . . . . . . . . . . . . . . . . . . MRS93-15BB . . . . . . . . . . . . . . . . . . 163 163 163 163 163 163 163 163 163 164 164 164 164 164 www.honeywell.com/sensing MRS93-16BB . . . . . . . . . . . . . . . . . . 164 MRS93-17BB . . . . . . . . . . . . . . . . . . 164 MRS93-18BB . . . . . . . . . . . . . . . . . . 164 P Precision Aerospace . . . . . . . . . . . . . 195 S SL1-A . . . . . . . . . . . . . . . . . . . . . . . . SL1-AK . . . . . . . . . . . . . . . . . . . . . . . SL1-B . . . . . . . . . . . . . . . . . . . . . . . . SL1-BK . . . . . . . . . . . . . . . . . . . . . . . SL1-D . . . . . . . . . . . . . . . . . . . . . . . . SL1-DK . . . . . . . . . . . . . . . . . . . . . . . SL1-E . . . . . . . . . . . . . . . . . . . . . . . . SL1-EK . . . . . . . . . . . . . . . . . . . . . . . SL1-H . . . . . . . . . . . . . . . . . . . . . . . . SL1-HK . . . . . . . . . . . . . . . . . . . . . . . SL1-K . . . . . . . . . . . . . . . . . . . . . . . . SL1-KK . . . . . . . . . . . . . . . . . . . . . . . SL1-P . . . . . . . . . . . . . . . . . . . . . . . . SL1-PK . . . . . . . . . . . . . . . . . . . . . . . SR-01 . . . . . . . . . . . . . . . . . . . . . . . . SRL91-22ARN3-BB9N . . . . . . . . . . . . SRL91-21URR3-BB99 . . . . . . . . . . . . SRL91-21UGG3-BB99 . . . . . . . . . . . . SRL91-22UGA3-BB99 . . . . . . . . . . . . SRL91-22UGG3-BB99 . . . . . . . . . . . . SRL91-23UGG3-BB99 . . . . . . . . . . . . SRL91-23URR3-BB99 . . . . . . . . . . . . SRL91-27URR3-BB99 . . . . . . . . . . . . SRN91-11BB . . . . . . . . . . . . . . . . . . . SRN91-12BB . . . . . . . . . . . . . . . . . . . SRN91-13BB . . . . . . . . . . . . . . . . . . . SRN91-14BB . . . . . . . . . . . . . . . . . . . SRN91-15BB . . . . . . . . . . . . . . . . . . . SRN91-16BB . . . . . . . . . . . . . . . . . . . SRN91-17BB . . . . . . . . . . . . . . . . . . . SRN91-18BB . . . . . . . . . . . . . . . . . . . SRN91-21BB . . . . . . . . . . . . . . . . . . . SRN91-22BB . . . . . . . . . . . . . . . . . . . SRN91-23BB . . . . . . . . . . . . . . . . . . . SRN91-24BB . . . . . . . . . . . . . . . . . . . SRN91-25BB . . . . . . . . . . . . . . . . . . . SRN91-26BB . . . . . . . . . . . . . . . . . . . SRN91-27BB . . . . . . . . . . . . . . . . . . . SRN91-28BB . . . . . . . . . . . . . . . . . . . SZL-VL-A . . . . . . . . . . . . . . . . . . . . . SZL-VL-B . . . . . . . . . . . . . . . . . . . . . SZL-VL-C . . . . . . . . . . . . . . . . . . . . . SZL-VL-D . . . . . . . . . . . . . . . . . . . . . SZL-VL-E . . . . . . . . . . . . . . . . . . . . . . SZL-VL-F . . . . . . . . . . . . . . . . . . . . . . SZL-VL-G . . . . . . . . . . . . . . . . . . . . . SZL-VL-H . . . . . . . . . . . . . . . . . . . . . SZR-LY2-1-AC110-120V . . . . . . . . . . 21 21 21 21 22 22 21 21 21 21 22 22 22 22 162 162 162 162 162 162 162 162 162 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 161 11 11 12 12 13 13 13 12 76 INDEX SZR-LY2-1-AC220V . . . . . . . . . . . . . SZR-LY2-1-DC12V . . . . . . . . . . . . . . SZR-LY2-1-DC24V . . . . . . . . . . . . . . SZR-LY2-1P-AC110-120V . . . . . . . . . SZR-LY2-1P-DC24V . . . . . . . . . . . . . SZR-LY2-D1-DC24V . . . . . . . . . . . . . SZR-LY2-N1-AC110-120V . . . . . . . . . SZR-LY2-N1-AC220V . . . . . . . . . . . . SZR-LY2-N1-DC12V . . . . . . . . . . . . . SZR-LY2-N1-DC24V . . . . . . . . . . . . . SZR-LY2-X1-DC24V . . . . . . . . . . . . . SZR-LY4-1-AC110-120V . . . . . . . . . . SZR-LY4-1-AC220V . . . . . . . . . . . . . SZR-LY4-1-DC12V . . . . . . . . . . . . . . SZR-LY4-1-DC24V . . . . . . . . . . . . . . SZR-LY4-1P-AC110-120V . . . . . . . . . SZR-LY4-1P-AC220V-240V . . . . . . . SZR-LY4-1P-DC24V . . . . . . . . . . . . . SZR-LY4-D1-DC24V . . . . . . . . . . . . . SZR-LY4-N1-AC110-120V . . . . . . . . . SZR-LY4-N1-AC220V . . . . . . . . . . . . SZR-LY4-N1-DC12V . . . . . . . . . . . . . SZR-LY4-N1-DC24V . . . . . . . . . . . . . SZR-LY4-X1-DC24V . . . . . . . . . . . . . SZR-MY2-1-AC110-120V . . . . . . . . . SZR-MY2-1-AC220V . . . . . . . . . . . . . SZR-MY2-1-DC12V . . . . . . . . . . . . . . SZR-MY2-1-DC24V . . . . . . . . . . . . . . SZR-MY2-1P-AC110-120V . . . . . . . . SZR-MY2-1P-AC220V-240V . . . . . . . SZR-MY2-1P-DC24V . . . . . . . . . . . . . SZR-MY2-D1-DC24V . . . . . . . . . . . . . SZR-MY2-N1-AC110-120V . . . . . . . . SZR-MY2-N1-AC220V . . . . . . . . . . . . SZR-MY2-N1-DC12V . . . . . . . . . . . . . SZR-MY2-N1-DC24V . . . . . . . . . . . . . SZR-MY2-X1-DC24V . . . . . . . . . . . . . SZR-MY4-1-AC110-120V . . . . . . . . . SZR-MY4-1-AC220V . . . . . . . . . . . . . SZR-MY4-1-DC12V . . . . . . . . . . . . . . SZR-MY4-1-DC24V . . . . . . . . . . . . . . SZR-MY4-1P-AC110-120V . . . . . . . . SZR-MY4-1P-AC220V-240V . . . . . . . SZR-MY4-1P-DC24V . . . . . . . . . . . . . SZR-MY4-D1-DC24V . . . . . . . . . . . . . SZR-MY4-N1-AC110-120V . . . . . . . . SZR-MY4-N1-AC220V . . . . . . . . . . . . SZR-MY4-N1-DC12V . . . . . . . . . . . . . SZR-MY4-N1-DC24V . . . . . . . . . . . . . SZR-MY4-X1-DC24V . . . . . . . . . . . . . SZX-SLF-08N . . . . . . . . . . . . . . . . . . SZX-SLF-14 . . . . . . . . . . . . . . . . . . . . SZX-SMF-08N . . . . . . . . . . . . . . . . . . SZX-SMF-14N . . . . . . . . . . . . . . . . . . 76 76 76 76 76 76 76 76 76 76 76 77 77 77 77 77 77 77 77 77 77 77 77 77 74 74 74 74 74 74 74 74 74 74 74 74 74 75 75 75 75 75 75 75 75 75 75 75 75 75 78 78 78 78 V V7-1A17D8 . . . . . . . . . . . . . . . . . . . V7-1A17D8-022 . . . . . . . . . . . . . . . V7-1A17P02 . . . . . . . . . . . . . . . . . . V7-1B10E9-207 . . . . . . . . . . . . . . . . V7-1B17D8 . . . . . . . . . . . . . . . . . . . V7-1B17D8-048 . . . . . . . . . . . . . . . V7-1B17D8-263 . . . . . . . . . . . . . . . V7-1B19D8-022 . . . . . . . . . . . . . . . V7-1B19E9 . . . . . . . . . . . . . . . . . . . V7-1C17D8 . . . . . . . . . . . . . . . . . . . V7-1C17D8-002 . . . . . . . . . . . . . . . V7-1C17D8-022 . . . . . . . . . . . . . . . V7-1C17D8-048 . . . . . . . . . . . . . . . V7-1C17D8-201 . . . . . . . . . . . . . . . V7-1C17D8-207 . . . . . . . . . . . . . . . V7-1C17D8-263 . . . . . . . . . . . . . . . V7-1C17E9 . . . . . . . . . . . . . . . . . . . V7-1C17E9-002 . . . . . . . . . . . . . . . . V7-1C17E9-201 . . . . . . . . . . . . . . . . V7-1C17E9-207 . . . . . . . . . . . . . . . . V7-1D10D8 . . . . . . . . . . . . . . . . . . . V7-1S17D8 . . . . . . . . . . . . . . . . . . . V7-1S17D8-022 . . . . . . . . . . . . . . . V7-1S17D8-201 . . . . . . . . . . . . . . . V7-1S17D8-207 . . . . . . . . . . . . . . . V7-1S17D8-263 . . . . . . . . . . . . . . . V7-1V19E9 . . . . . . . . . . . . . . . . . . . V7-1V19E9-048 . . . . . . . . . . . . . . . . V7-1V19E9-207 . . . . . . . . . . . . . . . . V7-1Z19E9 . . . . . . . . . . . . . . . . . . . V7-2B17D8-201 . . . . . . . . . . . . . . . V7-2B17E9-002 . . . . . . . . . . . . . . . . V7-2B19E9-048 . . . . . . . . . . . . . . . . V7-3S17D8-048 . . . . . . . . . . . . . . . V7-3S17E9-263 . . . . . . . . . . . . . . . . V7-7D17D8-207 . . . . . . . . . . . . . . . V7-9W1AE9-048 . . . . . . . . . . . . . . . Vehicle Controls . . . . . . . . . . . . . . . Hour Meters . . . . . . . . . . . . . . . . . . Indicator Light Strips . . . . . . . . . . Key Switches . . . . . . . . . . . . . . . . Lighting Products . . . . . . . . . . . . . Multi-function Controls . . . . . . . . Other Vehicle Controls . . . . . . . . . . Proportional Retarders . . . . . . . . . Push/Pull Switches . . . . . . . . . . . Shifters . . . . . . . . . . . . . . . . . . . . Throttle Controls . . . . . . . . . . . . . Turn Signals . . . . . . . . . . . . . . . . . 110 111 110 111 110 111 111 111 110 110 111 111 111 111 111 111 110 111 111 111 110 110 111 111 111 111 110 111 111 110 111 111 111 111 111 111 111 175 176 175 184 189 175 194 187 185 186 175 188 ZM50E10E01 . . . . . . . . . . . . . . . . . . ZM50E70A01 . . . . . . . . . . . . . . . . . . ZM50E70D01 . . . . . . . . . . . . . . . . . . ZM50E70E01 . . . . . . . . . . . . . . . . . . ZM90G20A01 . . . . . . . . . . . . . . . . . ZV10B70A01 . . . . . . . . . . . . . . . . . . ZV50E10A01 . . . . . . . . . . . . . . . . . . ZV50E10B01 . . . . . . . . . . . . . . . . . . ZV50E20A01 . . . . . . . . . . . . . . . . . . ZV50E20F01 . . . . . . . . . . . . . . . . . . ZV50E70C01 . . . . . . . . . . . . . . . . . . ZV50E70F01 . . . . . . . . . . . . . . . . . . ZW10E15CD1 . . . . . . . . . . . . . . . . . ZW10E90FW1 . . . . . . . . . . . . . . . . . ZW50F15AD1 . . . . . . . . . . . . . . . . . ZX10C10A01 . . . . . . . . . . . . . . . . . . ZX40E10C01 . . . . . . . . . . . . . . . . . . ZX40E10E01 . . . . . . . . . . . . . . . . . . ZX40E30A01 . . . . . . . . . . . . . . . . . . ZX40E30C01 . . . . . . . . . . . . . . . . . . ZX40E30E01 . . . . . . . . . . . . . . . . . . 108 107 108 108 107 108 108 109 108 109 109 109 109 109 109 107 107 108 107 107 108 Z ZM10B10A01 . . . . . . . . . . . . . . . . . 107 ZM50E10A01 . . . . . . . . . . . . . . . . . . 107 ZM50E10D01 . . . . . . . . . . . . . . . . . . 108 www.honeywell.com/sensing 209 SALES AND SERVICE Sales and Service Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorised Distributor or Sales Representative, contact your local sales office or: INTERNET: www.honeywell.com/sensing E-mail: info.sc@honeywell.com ASIA PACIFIC EUROPE Control Products Asia Pacific Headquarters Phone: +(65) 6355-2828 FAX: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799-6167 FAX: +(822) 792-9013 Australia Honeywell Limited Phone: +(61) 2-9370-4500 FAX: +(61) 2-9370-4525 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-0470 Malaysia Honeywell Engineering Sdn Bhd Phone: +(60-3) 7958-4988 FAX: +(60-3) 7958-8922 China – PRC - Beijing Honeywell China Inc. Phone: +(86-10) 8458-3280 FAX: +(86-10) 8458-3102 China – PRC - Shanghai Honeywell China Inc. Phone: (86-21) 6237-0237 FAX: (86-21) 6237-1237 China - Hong Kong S.A.R. Honeywell Ltd. Phone: +(852) 2953-6412 FAX: +(852) 2953-6767 Indonesia Honeywell Indonesia Pte Ltd. Phone: +(62) 21-535-8833 FAX: +(62) 21-5367 1008 India TATA Honeywell Ltd. Phone: +(91) 20 6870 445/ 446 FAX: +(91) 20 681 2243/ 687 5992 Japan Honeywell Inc Phone: +(81) 3 5440 1425 FAX: +(81) 3 5440 1368 New Zealand Honeywell Limited Phone: +(64-9) 623-5050 FAX: +(64-9) 623-5060 Toll Free (0800) 202-088 Philippines Honeywell Systems (Philippines) Inc. Phone: +(63-2) 636-1661 / 1662 FAX: +(63-2) 638-4013 Singapore Honeywell South East Asia Phone: +(65) 6355-2828 FAX: +(65) 6445-3033 Thailand Honeywell Systems (Thailand) Ltd. Phone: +(662) 693-3099 FAX: +(662) 693-3085 Taiwan R.O.C. Honeywell Taiwan Ltd. Phone: +(886-2) 2245-1000 FAX: +(886-2) 2245-3241 Austria Honeywell Austria GmbH Phone: +(43) 1 727 80 366/ 246 FAX: +(43) 1 727 80 337 Belgium Honeywell SA/NV Phone: +(32) 2 728 2522 FAX: +(32) 2 728 2502 Bulgaria Honeywell EOOD Phone: +(359) 2 979 00 23 FAX: +(359) 2 979 00 24 Czech Republic Honeywell spol. s.r.o. Phone: +(420) 242 442 111 FAX: +(420) 242 442 182 Denmark Honeywell A/S Phone: +(45) 39 55 55 55 FAX: +(45) 39 55 55 58 Finland Honeywell OY Phone: +(358) 9 3480101 FAX: +(358) 9 34801375 France Honeywell SA Phone: +(33) 1 60 19 80 40 FAX: +(33) 1 60 19 81 73 Germany Honeywell AG Phone: +(49) 69 8064 444 FAX: +(49) 69 8064 442 Hungary Honeywell Kft. Phone: +(361) 451 43 00 FAX: +(361) 451 43 43 Italy Honeywell S.p.A. Phone: +(39) 02 92146 450/ 456 FAX: +(39) 02 92146 490 The Netherlands Honeywell B.V. Phone: +(31) 20 565 69 11 FAX: +(31) 20 565 66 00 Norway Honeywell A/S Phone: +(47) 66 76 20 00 FAX: +(47) 66 76 20 90 Poland Honeywell Sp. zo.o Phone: +(48) 606 09 64 FAX: +(48) 606 09 01 210 Portugal Honeywell Portugal Lda Phone: +(351 21) 424 50 00 FAX: +(351 21) 424 50 99 Romania Honeywell Bucharest Phone: +(40) 21 231 64 37/ 38 FAX: +(40) 21 231 6439 Commonwealth of Independent States (CIS) Z.A.O. Honeywell Phone: +(7 095) 796 98 36 FAX: +(7 095) 797 99 06 Slovak Republic Honeywell s.r.o. Phone: +(421 2) 58 247 403 FAX: +(421 2) 58 247 415 South Africa (Republic of) Honeywell Southern Africa Honeywell S.A. Pty. Ltd Phone: +(27) 11 695 8000 FAX +(27) 11 805 1504 Spain Honeywell S.A. Phone: +(34) 91 313 6100 FAX: +(34) 91 313 6129 Sweden Honeywell AB Phone: +(46) 8 775 55 00 FAX: +(46) 8 775 56 00 Switzerland Honeywell AG Phone: +(41) 1 855 24 40 FAX: +(41) 1 855 24 45 Turkey Honeywell Turkey A.S. Phone: +(90) 216 5756620 FAX: +(90) 216 5756637 Ukraine Honeywell Phone: +(380) 44 201 44 74 FAX: +(380) 44 201 44 75 United Kingdom Honeywell Control Systems Ltd Phone: +(44) 1698 481481 FAX: +(44) 1698 481676 Mediterranean & African Distributors Honeywell SpA Phone: +(39) 2 921 46 232 FAX: +(39) 2 921 46 233 Middle East Headquarters Honeywell Middle East Ltd. Phone: +(9712) 443 2119 FAX +(9712) 443 2536 www.honeywell.com/sensing NORTH AMERICA LATIN AMERICA USA/Canada Honeywell Sensing and Control Phone: 1-800-537-6945 1-815-235-6847 FAX: 1-815-235-6545 E-mail: info.sc@honeywell.com Honeywell Latin America Headquarters Phone: 1-305-805-8188 FAX: 1-305-883-8257 Argentina Honeywell S.A.I.C. Phone: +(54-11) 4383-3627 FAX: +(54-11) 4325-6470 Brazil Honeywell Do Brasil & Cia Phone: +(55-11) 4166-1900 FAX: +(55-11) 4166-1901 Chile Honeywell Chile, S.A. Phone: +(56-2) 425-8400 FAX: +(56-2) 425-8410 Mexico Honeywell S.A. de C.V. Phone: +(52) 55 5081-0200 FAX: +(52) 55 5081-0202 Puerto Rico, Caribbean Honeywell Inc. Phone: +(787) 792-7075 FAX: +(787) 792-0053 Venezuela Honeywell C.A. Phone: +(58-212) 273-0511 FAX: +(58-212) 273-0599 Warranty/Remedy While we provide application assistance personally, through Honeywell warrants goods of its manufacture as being free of our literature and the Honeywell web site, it is up to the defective materials and faulty workmanship. Honeywell's customer to determine the suitability of the product in the standard product warranty applies unless agreed to otherwise application. by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for Specifications may change without notice. The information we specific warranty details. If warranted goods are returned to supply is believed to be accurate and reliable as of this Honeywell during the period of coverage, Honeywell will printing. However, we assume no responsibility for its use. repair or replace, at its option, without charge those items it egoing is buyer's sole rremedy emedy and finds defective. The for foregoing is in lieu of all other war ranties, expr essed or implied, warranties, expressed including those of mer chantability and fitness for a merchantability par ticular purpose. In no event shall Honeywell be liable particular for consequential, special, or indir ect damages. indirect Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com 000640-1-EN IL50 GLO July 2006 Copyright © 2006 Honeywell International Inc. All rights reserved.
82401-56 价格&库存

很抱歉,暂时无法提供与“82401-56”相匹配的价格&库存,您可以联系我们找货

免费人工找货