MICRO SWITCH™
914CE Series
Compact Limit Switch
DESCRIPTION
All MICRO SWITCH™ 914CE series compact enclosed switches
incorporate fluorocarbon diaphragm sealing to provide reliable
protection, meeting NEMA 1, 2, 3, 3R, 4, 6, 6P, and 13 as well as
IP66, IP67, and IP68 requirements. Versions with boot seal also
meet NEMA 12 requirements (dust, falling dirt, liquid media with
solid contaminates). The cable or connector and basic switch
terminals are encapsulated in an epoxy compound, offering
superior resistance in harsh environments. For low temperature
applications (down to -40 °C, -40 °F), CE switches can be supplied with low temperature seals and lubricant.
The CE switches are a rugged and versatile switch which can
be applied indoors in harsh factory floor applications, as well as
on outdoor equipment in extreme temperatures. A full range of
actuators are available, including plain plungers, roller plungers,
side rotary, multi-directional wire, and manually operated. The
switches are also available with the industry standard, M12 miniature 4-pin connector. MICRO SWITCH™ 914CE products meet
UL and CSA standards, as well as European CE requirements.
FEATURES
POTENTIAL APPLICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Compact construction
Pre-wired or connector versions
Die-cast zinc housing
Wide selection of actuators
Gang mounting capability
Cable length variations
Side and bottom exit cable/connector
Simple two-screw mounting
Low temperature variants
Fluorocarbon sealing (standard)
Approvals: UL, CSA, CE
Processing equipment
Textile machinery
Machine tools
Robotics
Packaging equipment
Farm machinery
Commercial laundry equipment
Printing Trade machinery
Vehicles
MICRO SWITCH™ 914CE Series
SPECIFICATIONS
Characteristic
Parameter
Description
Compact enclosed limit switch
Actuators
• Top pin plunger
• Top pin plunger with boot seal
• Top pin plunger (panel mounted)
• Ball bearing plunger
• Adjustable plunger
• Manually operated
• Cross roller plunger
• Wobble
• Parallel top roller plunger
• Parallel & boot sealed top roller plunger
• Parallel and panel-mounted top roller plunger
Terminations
• SJTO 4 x 0,75 mm2 (18 AWG) cable
• Connector (dc), 4-pin male, M12 thread (-Q)
• Connector (ac), 4-pin male, 1/2 in x 20 thread (-Q1)
Switching options
SPDT, snap action contacts (1NC/1NO)
Sealing
IP66, IP67, IP68 (depending upon model)
NEMA 1, 2, 3, 3R, 4, 6, 6P, 12 (boot seal), 13
Operating temperature (914CE)
0 °C to 105 °C [32 °F to 221 °F]
Mechanical life
10 million
Thermal current
1 A, 5 A, 10 A (depending upon model)
Rated Insulation voltage (Ui)
250 V
Rated impulse withstand voltage 1.5 kV
(Uimp)
Pollution degree
3
Min. actuation speed
0.003 m/s
Max. actuation speed
0.1 m/s
Max. actuation frequency
ac – 200 Hz; dc – 20 Hz
Shock
50 g – IEC68-2-27
Vibration
10 G – IEC68-2-6
Approvals (914CE)
UL, CSA, CE
Conforming to standards
• IEC947-5-1, EN 60947-5-1
• UL recognized to US and Canadian Requirements (914CE only)
ELECTRICAL RATINGS
Model example
914CE* - *
914CE* - *G
914CE* -Q, -AQ, -AQ1
Contacts
Silver contacts
Gold contacts
Silver contacts
Rating
A
B
C
Rating Code Electrical rating
A
UL/CSA
Make
Break
240 Vac, Ind.
1.2
0.2
240 Vac, res.
5
5
28 Vdc, res.
3
3
28 Vdc, ind.
3
3
5 A, 1/10 HP, 125 Vac or 250 Vac
B
UL
1 A res., 0.5 A ind., 30 Vdc
1 A, 125 Vac
C
UL/CSA
3 A, 125 Vac or 250 Vac
2 Honeywell • Sensing and Control
Compact Limit Switch
SWITCHING AND LEAD IDENTIFICATION
914CE
GREEN
SPDT
RED
2
BLACK
1
2
3
WHITE
3
1
PINOUTS
Connector - (dc)
Connector (ac)
NO 3
2
3
1
NC
CONNECTOR
VERSIONS
NO 3
1C
The 914CE Series is available with a metal 4-pin, M12 size connector in both bottom and side exit versions.
NC
Q Version
Q1 Version
15
15
8.0
connector
dcBrad
typeHarrison
4 pin male
,
CAT.thread
No.80466 M12 Thread
M12
OPTION Q
1C
OPTION Q1
ac type, 4 pin male,
1/2 in x 20 thread
MOUNTING
MICRO SWITCH™ 914CE Series switches are mounted by using
two M5 screws. The mounting holes are counter bored to keep
the screw heads within the overall switch housing dimensions.
GANG MOUNT CAPABILITY
The housing on the 914CE Series has been designed to enable
the user to build his own multiple plunger switch by gang mounting several switches. All pin plunger and roller plunger types are
suitable for gang mounting. There is a 16 mm distance between
the plungers. Both series are very versatile that even a levertype version could be added at the end of the row.
BOTTOM EXIT OR SIDE EXIT ORIENTATION
The CE Series has been designed with a pre-wired cable fittied
in the bottom of the switch housing. Other variations are available with a side exit cable.
GOLD CONTACT VERSIONS
For low current applications (up to 30 Vdc, 1 A), gold contact
basic versions of the 914CE switches can be supplied upon
request.
Honeywell • Sensing and Control 3
MICRO SWITCH™ 914CE Series
GENERAL DIMENSIONS • ALL SWITCHES
CABLE VERSION
40 mm max.
[1.57 in max.]
16 mm max.
[0.63 in max.]
25 mm
[0.98 in]
Two (2) holes Ø 5.1 mm [Ø 0.2 in] dia. c/bore
10,2 mm dia x 6 mm deep [0.40 in dia x 0.24 in deep]
(Both sides - option “A” only)
Pretravel (PT)
Overtravel (OT)
3 mm min.
[0.12 in min.]
Max. free length
Operating
position (OP)
7,6 mm
[0.30 in]
M12
thread
44 mm max.
[1.73 in max.]
SWITCH™ 914CE Miniature Limit Switch
8,0 mm
t Nomenclature
[0.31 in]
TYPE
Q OE Q2
8,0 mm
[0.32 in]
1/2 x 20 UNF
thread
TYPE
Q1
PRODUCT NOMENCLATURE
29
Switch Type
Actuator Type
914CE Series
Small Precision
Limit Switch
3
–
914CE
Q
dc type
Brad Harrison
Gold
contacts
Q1
ac type
two keyways
Top
mounting
Q2
dc type
plastic
1
Top pin
plunger
22
Manually oper.
nylon button
3
3 feet
A
Side entry
2
Top roller
plunger, parallel
27
Top pin plunger
panel mount
6
6 feet
G
3
Top roller
plunger, perp.
28
Top roller
plunger, parallel
panel mount
9
9 feet
P
16
Front
rotary
29
Top roller
plunger, perp.
panel mount
12
12 feet
L1
Low temp.
-40 °C, cable
not for flexing
18
Top pin plunger
w/ boot seal
31
Top roller
plunger, parallel
boot seal
15
15 feet
V
Vitron seals/
gasket
(front rotary only)
19
Top adjustable
pin plunger
55
Top roller
plunger, perp.
boot seal
20
Coil
wobble
66 plunger
Top ball bearing
NOTE: not all combinations of model code are available.
Please contact your Honeywell provider/representative for assistance.
4 Honeywell • Sensing and Control
Connectors
Options
Cable Length
Bottom exit is
standard.
Compact Limit Switch
PRODUCT SPECIFICATIONS AND LISTINGS
Contact your Honeywell rep or distributor for additional listings
914CE1 • Pin Plunger
914CE27 • Pin Plunger Panel Mount
Ø10,0 mm
[Ø0.39 in]
PT
OT
FP
OP
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 12,2 N [2.75 in-lb]
M10 X 1 METRIC THREAD
12 mm [0.49 in]
THREADED LENGTH
OT
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3
Bottom
UL, CSA, CE
–
914CE1-3
Gold
B
1, 3
Bottom
UL, CSA, CE
–
914CE1-3G
Silver
A
1, 3
Side
UL, CSA, CE
–
914CE1-3A
Silver
A
1, 3
Bottom
UL, CSA, CE
Panel mount
914CE27-3
Silver
C
1, 3
Bottom
UL, CSA, CE
ac-type, two keyways
914CE1-Q1
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3, 4, 12, 13
Bottom
UL, CSA, CE
Silver
A
1, 3, 4, 12, 13
Side
UL, CSA, CE
Silver
A
1, 3, 4, 12, 13
Bottom
UL, CSA, CE
Fluorocarbon seals
914CE18-3V
Silver
C
1, 3, 4, 6, 12, 13
Bottom
UL, CSA, CE
ac-type, two keyways
914CE18-Q1
Silver
C
1, 3, 4, 6, 12, 13
Side
UL, CSA, CE
ac-type, two keyways
914CE18-AQ1
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3
Bottom
UL, CSA, CE
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Silver
A
1, 3
Bottom
UL, CSA, CE
914CE2-3
Gold
B
1, 3
Bottom
UL, CSA, CE
914CE2-3G
Silver
C
1, 3
Bottom
UL, CSA, CE
Silver
A
1, 3
Side
UL, CSA, CE
Silver
A
1, 3
Bottom
UL, CSA, CE
Panel mount
914CE28-3
Silver
C
1, 3
Bottom
UL, CSA, CE
Panel mount, ac-type, two
keyways
914CE28-Q1
PT
FP
OP
914CE18 • Boot Sealed Pin Plunger
BOOT SEAL
Ø7,0 mm
[Ø0.28 in]
OT
PT
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 22,2 N [5 in-lb]
FP
OP
914CE66 • Ball Bearing Plunger
7,9 mm [0.31 in] DIA
BALL BEARING
914CE18-3
914CE18-3A
914CE66-3
PT
OT
FP
OP
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 12,2 N [2.75 in-lb]
914CE2 • Roller Plunger
914CE28 • Roller Plunger Panel Mount
Ø12,4 mm
[Ø0.49 in]
PT
OT
FP
OP
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 12,2 N [2.75 in-lb]
ROLLER
Ø 12,4 mm x 4,7 mm
[Ø 0.48 in x 0.020 in]
M14 X 1 THREAD
Options
ac-type, two keyways
Listing
914CE2-Q1
914CE2-3A
OT
PT
OP
FP
Honeywell • Sensing and Control 5
MICRO SWITCH™ 914CE Series
914CE31 • Boot Sealed Roller Plunger
ROLLER
Ø 12,4 mm x 4,7 mm
Ø 0.48 in x 0.020 in]
BOOT SEAL
PT
OT
FP
OP
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 22,2 N [5 in-lb]
914CE3 • Cross Roller Plunger
914CE29 • Cross Roller Panel Mount
Ø12,4 mm
[Ø0.49 in]
PT
OT
FP
OP
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3, 4, 6, 6P,
12, 13
Bottom
UL, CSA, CE
Silver
A
1, 3, 4, 6, 6P,
12, 13
Bottom
UL, CSA, CE
Flurocarbon seals
914CE31-3V
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3
Bottom
UL, CSA, CE
914CE3-3
Gold
B
1, 3
Bottom
UL, CSA, CE
914CE3-3G
Silver
A
1, 3
Side
UL, CSA, CE
Silver
A
1, 3
Bottom
UL, CSA, CE
Panel mount
914CE29-3
Silver
C
1, 3
Bottom
UL, CSA, CE
ac-type, two keyways
914CE3-Q1
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3, 4, 6, 6P,
12, 13
Bottom
UL, CSA, CE
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Silver
A
1, 3, 4, 6, 6P,
12, 13
Bottom
UL, CSA, CE
914CE16-31
Silver
A
1, 3, 4, 6, 6P,
12, 13
Side
UL, CSA, CE
914CE16-3A1
Silver
C
1, 3, 4, 6, 12, 13
Bottom
UL, CSA, CE
ac-type, two keyways
914CE16-Q11
Silver
C
1, 3, 4, 6, 12, 13
Side
UL, CSA, CE
ac-type, two keyways
914CE16-AQ11
914CE31-3
914CE3-3A
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 12,2 N [2.75 in-lb]
ROLLER
Ø 12,4 mm x 4,7 mm
Ø 0.48 in x 0.020 in]
M14 X 1 THREAD
OT
PT
FP
OP
914CE55 • Boot Sealed Cross Roller
Plunger
ROLLER
Ø 12,4 mm x 4,7 mm
Ø 0.48 in x 0.020 in]
BOOT SEAL
PT
OT
FP
OP
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 22,2 N [5 in-lb]
914CE16 • Side Rotary
FP
PT
OT
DT
Actuator shaft
Ø7,32 mm
[Ø0.288 in]
914CE55-3
PT
OT
DT
18,9 mm
[0.74 in]
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 22,2 N [5 in-lb]
Options
Listing
Note: part numbers are shown with 3 ft of cable. The -X indicates the number of feet of cable provided. Six-foot, 9-foot lengths, and 12-foot lengths along with custom
amounts, are also available.
1
Switch operates on clockwise and counterclockwise rotation of lever shaft
6 Honeywell • Sensing and Control
Compact Limit Switch
914CE22 • Manually Operated
NYLON BUTTON
Ø26,4 mm
[Ø1.04 in]
OT
FP
M4 CORROSION
RESISTANT SCREW AND LOCKNUT
PT
OT
FP
[ADJUSTABLE]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 17,5 N [5 lb]
914CE20 • Random Motion Wire Actuator
OP
ALL DIRECTIONS
EXCEPT DIRECT
PULL
335,0 mm max.
[13,98 mm max.]
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3
Bottom
UL, CSA, CE
23,9 mm [0.94 in] dia.
button
914CE22-3
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 3
Bottom
UL, CSA, CE
914CE19-3
Gold
B
1, 3
Bottom
UL, CSA, CE
914CE19-3G
Silver
A
1, 3
Side
UL, CSA, CE
Silver
C
1, 3
Bottom
UL, CSA, CE
ac-type, two keyways
914CE19-Q1
Contacts
Elec
Rating
NEMA
Cable exit
Approvals
Options
Listing
Silver
A
1, 2, 3, 3R, 4, 6,
6P, 13
Bottom
UL, CSA, CE
914CE20-3
1, 2, 3, 3R, 4, 6,
6P, 13
Side
UL, CSA, CE
914CE20-3A
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 8,9 N [2 in-lb]
914CE19 • Adjustable Plunger
Ø1.8 mm
[Ø0.07 in]
Elec
Rating
PT
OP
OP
Contacts
Pretravel • 1,0 mm ±0,5 mm
[0.04 in ±0.02 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 0,55 N [0.12 lb]
Silver
914CE19-3A
A
Note: part numbers are shown with 3 ft of cable. The -X indicates the number of feet of cable provided. Six-foot, 9-foot lengths, and 12-foot lengths along with custom
amounts, are also available.
1
Switch operates on clockwise and counterclockwise rotation of lever shaft
Honeywell • Sensing and Control 7
MICRO SWITCH™ 914CE Series
This Honeywell datasheet supports the following MICRO SWITCH™ 914CE Series Limit Switch Listings
914CE1-15
914CE1-3
914CE1-3A
914CE1-3G
914CE1-6
914CE16-12
914CE16-18
914CE16-18V
914CE16-27
914CE16-3
914CE16-3A
914CE16-3N1
914CE16-6
914CE16-6A
914CE16-6AN14
914CE16-9
914CE16-9A
914CE1-6A
914CE16-AQ
914CE1-6L1
914CE16-Q
914CE16-Q1
914CE16-Q2
914CE16-QV
914CE16-VCQ1
914CE18-12
914CE18-15
914CE18-15A
914CE18-27
914CE18-3
914CE18-3A
914CE18-3AL1
914CE18-6
914CE18-6A
914CE18-9
914CE18-9A
914CE18-9AGL1
914CE18-9AL1
914CE18-AQ
914CE18-AQ1
914CE18-Q
914CE18-Q1
914CE1-9
914CE19-12
914CE19-3
914CE19-6
914CE19-9
914CE19-9A
914CE1-9A
914CE1-AQ
914CE1-AQ1
914CE1-Q
914CE1-Q1
914CE1-Q2
914CE20-12
914CE20-3
914CE20-6
914CE20-9
914CE20-9L1
914CE20-N77
914CE20-Q
914CE20-Q1
914CE2-12
914CE2-12GKL1
914CE2-15
914CE22-12
914CE22-6
914CE2-27
914CE2-3
914CE2-33N37
914CE2-3A
914CE2-3AL1
914CE2-3L1
914CE2-6
914CE2-6A
914CE2-6-C
914CE2-6G
914CE27-3
914CE27-6
914CE27-GQ1
914CE27-Q
914CE28-12
914CE28-18
914CE28-3
914CE28-6
914CE28-9
914CE28-Q
914CE2-9
914CE29-3
914CE29-6
914CE29-9L1
914CE2-9A
914CE2-9AL1
914CE2-9C
914CE2-9G
914CE2-9L1
914CE29-Q
914CE2-AGQ
914CE2-AQ
914CE2-KQ
914CE2-Q
914CE2-Q1
914CE2-Q2
914CE31-12
914CE31-12A
914CE31-18
914CE3-12
914CE31-3
914CE31-3L1
914CE31-6
914CE31-9AL1
914CE31-9L1
914CE31-9V
914CE31-AQ
914CE3-3
914CE3-3A
914CE3-3L1
914CE3-6
914CE3-6A
914CE3-9
914CE3-9L1
914CE3-AQ
914CE3-KQ
914CE3-Q
8 Honeywell • Sensing and Control
914CE3-Q1
914CE55-12
914CE55-3
914CE66-3
914CE66-6
914CE1-12
914CE1-12A
914CE1-15A
914CE1-3AK
914CE1-3AKV
914CE1-3K
914CE1-AKQ
914CE1-AKQ1
914CE1-GQ1
914CE1-KQ
914CE1-KQ1
914CE18-21A
914CE18-9V
914CE18-GQ
914CE2-12AK
914CE2-12GK
914CE2-12KL1
914CE2-15A
914CE2-18
914CE2-21
914CE2-24K
914CE2-33
914CE2-33AK
914CE2-33K
914CE2-3AK
914CE2-3G
914CE2-3K
914CE2-3KL1
914CE2-3KV
914CE2-6AK
914CE2-6K
914CE2-6KV
914CE2-9AK
914CE2-9K
914CE2-9KL1
914CE2-AKLQ
914CE2-AKQV
914CE2-AQ1
914CE2-KQ1
914CE2-KQV
914CE20-12G
914CE20-12GL1
914CE22-3
914CE22-9
914CE27-12
914CE27-9
914CE27-AGQ1
914CE28-Q1
914CE29-9
914CE3-12AK
914CE3-12K
914CE3-3AK
914CE3-3G
914CE3-3K
914CE3-3KL1
914CE3-6AK
914CE3-6G
914CE3-6K
914CE3-9AK
914CE3-9G
914CE3-9K
914CE3-9V
914CE3-AKQ
914CE3-KQ1
914CE31-12AV
914CE31-3A
914CE31-3V
914CE55-3AG
914CE553A
914CE66-12
914CE66-9
MICRO SWITCH™ 914CE Series
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
Compact Limit Switch
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives
and distributors. For application
assistance, current specifications, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847/
1-800-537-6945, visit
sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
sensing.honeywell.com
002381-1-EN IL50 GLO
March 2013
Copyright © 2013 Honeywell International Inc. All rights reserved.