ASDXL DO Series
Microstructure Pressure
Sensors
0 in to ±5 in H2O, 0 in to 10 in
H2O, 0 in to ±10 in H2O
DESCRIPTION
All ASDXL DO sensors are accurate to within ±2.5 % Full
The ASDXL DO Series pressure sensors are fully calibrated
Scale Span (FSS) and are intended for use with non-corrosive,
and temperature compensated with on-board Application
non-ionic working fluids such as air and dry gases. (Contact
Specific Integrated Circuitry (ASIC). This ASDXL DO sensor is
factory for media compatibility on G2/D4 packages.)
in a DIP format (Dual In-line Package) and provides digital
correction of sensor offset, sensitivity, temperature coefficients
2
This series is designed and manufactured in accordance with
and non-linearity. The ASDXL DO Series has 12-bit I C
ISO 9001 standards and is compliant with the WEEE and
compatible protocol interface which allows easy interfacing to
RoHS directives.
most commonly used microcontrollers and microprocessors.
2
The 2-wire I C interface has a Serial Clock Line input (SCL)
and serial digital output data line. The output of the device is a
corrected pressure value in hexadecimal format with 12-bit
accuracy (unsigned) and not ratiometric to the supply voltage.
FEATURES
POTENTIAL APPLICATIONS
•
Available in differential and gage packages
•
Medical equipment
•
Calibrated and temperature compensated output
•
HVAC controls
•
12-bit digital output (I C compatible protocol)
•
Pneumatic controls
•
Pressure ranges from 0 in to ±5 in H2O, 10 in H2O,
2
±10 in H2O
•
Response time of 8 ms
•
DIP package
•
ASIC-enhanced output
ASDXL DO Series
0 in to ±5 in H2O, 0 in to 10 in H2O, 0 in to ±10 in H2O
GENERAL SPECIFICATIONS
Characteristic
Supply voltage (Vs)
Maximum supply voltage
Current consumption
Output current - sink
Output current - source
Parameter
4.75 Vdc to 5.25 Vdc
6.50 Vdc max.
6 mA typ.
2 mA max.
2 mA max.
Characteristic
Lead soldering temperature
Vibration
Shock
Life
Position sensitivity
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Compensated
Operating
Storage
PRESSURE RANGE SPECIFICATIONS
Range
0 °C to 85 °C [32 °F to 185 °F]
-20 °C to 105 °C [-4 °F to 221 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
PERFORMANCE CHARACTERISTICS 4D DO
Characteristic
(4,5)
Full scale span (FSS)
(5)
Zero pressure offset
(5,6)
Output at full scale pressure (P2)
(5,6)
Output at full scale pressure (P1)
(7)
Accuracy
Output resolution
(8)
Response time
Listing
ASDXL05
ASDXL10
Pressure Range
0 in to ±5 in H20
0 in to 10 in H20
0 in to ±10 H20
Burst Pressure
3 PSI
(1)
3 PSI
(2,3)
Min.
–
07AE
0E14
0147
–
–
–
PERFORMANCE CHARACTERISTICS 4R DO
Characteristic
(4,5)
Full scale span (FSS)
(5)
Zero pressure offset
(5)
Output at full scale pressure
(7)
Accuracy
Output resolution
(8)
Response time
Parameter
4 s at 250 °C [482 °F]
10 g at 20 Hz to 2000 Hz
100 g for 11 ms
1 million cycles min.
50 µV/V/g typical
Typ.(5)
CCC
0800
0E66
019A
–
12
8
Max.
–
0851
0EB8
01EB
±2.5
–
11
Unit
counts hex
counts hex
counts hex
counts hex
% FSS
bit
ms
Typ.
CCC
019A
0E66
–
12
8
Max.
–
01EB
0EB8
±2.5
–
11
Unit
counts hex
counts hex
counts hex
% FSS
bit
ms
(2,3)
Min.
–
0147
0E14
–
–
–
Notes:
1. If burst pressure is exceeded, even momentarily, the package may leak or the pressure sensing die may fracture.
2. Reference conditions (unless otherwise noted): supply voltage, VS=5.0 ±0.01 Vdc, Ta=25 °C [77 °F].
3. Read operation: Start, Slave Address, R/W =1, Data Byte 1 (MSB), Ackn Bit, Data Byte 2 (LSB). The output is corrected pressure as unsigned
12 bits. Slave Address is F0h. Acknowledge Bit - pull data line LOW, master generates an extra clock pulse for this purpose.
4. Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure.
5. Output is non-ratiometric within the supply voltage range (Vs).
6. Output of the device when maximum positive pressure is applied on the backside (P2) or the front side (P1) of the sensing element.
7. Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Calibration errors
include the deviation of offset and full scale from nominal values Linearity is the measured deviation based on a straight line. Hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure and temperature.
8. Response time for 0 PSI to full scale pressure step change, 10% to 90% rise time.
9. 220 nF capacitor required between +Vs and GND.
ELECTRICAL CONNECTIONS
(1,2,3)
ASDXLYYD4ZZ-DO
ASDXLYYG2ZZ-DO
Notes:
1. N/C means no connection. Connecting to ground or other potential may damage sensors.
2. Capacitor 220 nF required between +Vs and GND.
3. The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause electrical failure.
Application of supply voltage above the maximum can cause electrical failure.
2
www.honeywell.com/sensing
Microstructure Pressure Sensors
DIMENSIONS (For reference only, mm/in.)
D4 Package
G2 Package
SERIAL INTERFACE PARAMETERS
Parameter
Input high level
Input low level
Output low level
Pull up current
Load capacitance SDA
SCL clock frequency
Bus free time between STOP
and START condition
Hold time (repeated) START
condition
LOW period of SCL
High period of SCL
Setup time repeated START
condition
Data hold time
Data setup time
Rise time of both SDA and SCL
Fall time of both SDA and SCL
Setup time for STOP condition
Input filter spike suppression
Symbol
VIH
VIL
VOL
VOH
CLSDA
fSCL
Condition
–
–
open drain IOL = -4 mA
pin SCL and SDA
–
–
Min.
4.5
0
–
5
–
–
Typ.
–
–
–
–
–
–
Max.
1
0.5
0.1
20
400
100
Unit
Vs
Vs
Vs
µA
pF
kHz
tBUF
–
4.7
–
–
µs
tHD,STA
to first clock pulse
4.0
–
–
µs
tLOW
tHIGH
–
–
4.7
4.0
–
–
–
–
µs
µs
tSU, STA
–
4.7
–
–
µs
tHD, DAT
tSU, DAT
tR
–
–
–
–
–
spikes on SDA or SCL of that
length are suppressed
0
250
–
–
4
–
–
–
–
–
–
–
300
300
–
ns
ns
ns
ns
µs
–
–
50
µs
tSU, STO
tsp
SERIAL INTERFACE TIMING CHARACTERISTICS
BLOCK DIAGRAM
Honeywell Sensing and Control
3
ORDERING INFORMATION
Pressure Range
Gage
Differential
Bidirectional
0 in to ±5 in H2O
–
–
ASDXL05D44D-DO
0 in to 10 in H2O
ASDXL10G24R-DO
ASDXL10D44R-DO
–
0 in to ±10 in H2O
–
–
ASDXL10D44D-DO
WARNING
WARNING
PERSONAL INJURY
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
•
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
008140-2-EN IL50 GLO Printed in USA
June 2006
Copyright © 2006 Honeywell International Inc. All rights reserved.