Board Mount Pressure
Sensors Line Guide
The pressure is on. The answer is here. No matter the need,
Honeywell Safety and Productivity Solutions (S&PS) has the
microstructure, pressure sensor solution. Our sensing element
design consists of four piezoresistors on a chemically etched
silicon diaphragm. A pressure change will cause a strain in
the diaphragm and the buried resistors. The resistor values will
change in proportion to the stress applied, which produces
an electrical output. You will find our components performing
in potential applications including dialysis equipment, blood
analysis, centrofusion and oxygen and nitrogen gas distribution,
HVAC devices, data storage, process controls, industrial
machinery, pumps, and robotics. Honeywell S&PS is always
working harder, no matter the situation. Or the pressure.
FEATURES
ULTRA-LOW PRESSURE SENSORS
TruStability™ RSC Series.
Features: Enhanced performance
• Proprietary Honeywell technology
• Cost-effective, high volume solution
with variety of options • High burst and
working pressures • Enhanced reliability
• Easy to design in • Meets IPC/JEDEC
J-STD-020D.1 Moisture Sensitivity Level 1
requirements • Energy efficient
Benefits: Output accelerates performance
through reduced conversion requirements
and direct interface to microprocessors.
High sensitivity with high burst and
overpressure while providing industryleading stability (performance factors
difficult to achieve in the same sensor)
provide flexibility in implementation and
minimize requirements for protecting the
sensor without sacrificing ability to sense
very small changes in pressure. High
burst pressures promote system reliability,
minimize downtime, and can simplify
design; high working pressures allow
ultra-low sensors to be used continuously
above the calibrated pressure range.
Package is small when compared to many
similar sensors, occupying less area on
the PCB. Port and housing options simplify
integration. Wide pressure range simplifies
use. IPC/JEDEC J-STD-020D.1 Moisture
Sensitivity Level 1 requirements allows
avoidance of thermal and mechanical
damage during solder reflow attachment
and/or repair that lesser rated sensors
would incur, allows unlimited floor life
when stored as specified (simplifying
storage and reducing scrap), eliminates
lengthy bakes prior to reflow, and allows
for lean manufacturing due to stability
and usability shortly after reflow. Energy
efficiency reduces system power
requirements and enables extended
battery life. Potential medical applications
include airflow monitors, anesthesia
machines, blood analysis machines, gas
chromatography, gas flow instrumentation,
hospital room air pressure, kidney dialysis
machines, nebulizers, pneumatic controls,
respiratory machines, sleep apnea
equipment, spirometers, and ventilators.
Potential industrial applications include
barometry, drones, flow calibrators, gas
chromatography, gas flow instrumentation,
HVAC clogged filter detection, HVAC
systems, HVAC transmitters, indoor air
quality, life sciences, pneumatic control,
VAV (Variable Air Volume) control, and
weather balloons.
TruStability™ HSC Series.
Features: Proprietary Honeywell
technology • Industry-leading long-term
stability, Total Error Band, and accuracy
• High burst pressures • High working
pressure ranges • Industry-leading
flexibility • Excellent repeatability
• Onboard signal conditioning • Wide
variety of pressure ranges • Meets IPC/
JEDEC J-STD-020D.1 Moisture Sensitivity
Level 1 requirements • Insensitive to
mounting orientation • Custom calibration
• Insensitive to vibration • Internal
diagnostic functions • Energy efficient
• I2C- or SPI-compatible digital output
or analog output • Small size • RoHS
compliant • Protected by multiple global
patents • Intended for use with noncorrosive, non-ionic working fluids
Benefits: Proprietary Honeywell
technology combines high sensitivity with
high overpressure and burst pressure to
give the customer more flexibility in sensor
implementation and reduce the customer
design requirements for protecting the
sensor without sacrificing the ability to
sense very small changes in pressure.
Industry-leading long-term stability
minimizes system calibration needs,
maximizes system performance, and
helps support system uptime by
sensing.honeywell.com 1
continued on page 7
Board Mount Pressure Sensors Line Guide
Working better under
pressure.
The human body is a
supremely sensitive
mechanism, requiring equally
perceptive observation.
Honeywell S&PS offers a line
of pressure sensors equal
to every task — including
sensors that measure the
amount of pressure delivered
to the human body.
From medical applications
to industrial needs to any
industry, we’ve got the right
solution. Our categories of
pressure sensor measurement
include absolute, differential,
gage or vacuum gage —
with unamplified or amplified
sensors covering wide
pressure ranges. You’ll also
find a variety of mounting
and package styles, digital
output, small size, reduced
cost, enhanced reliability,
enhanced repeatability and
accuracy under extreme
conditions, enhanced
operating characteristics
between sensors, and
interchangeability without
recalibration.
2 sensing.honeywell.com
Ultra-Low
Pressure Sensors
TruStability™
TruStability™
Signal conditioning
amplified
amplified
Pressure range
±1.6 mbar to ±40 mbar |
±160 Pa to ±4 kPa |
±0.5 inH2O to ±30 inH2O
±1.6 mbar to ±40 mbar |
±160 Pa to ±4 kPa |
±0.5 inH2O to ±30 inH2O
Device type
differential, gage
differential, gage
Output
24-bit digital (SPI)
analog (Vdc) or digital (I2C or SPI)
Calibrated
yes
yes
Temperature Compensated
yes
yes
Operating temperature range
-40 °C to 85 °C [-40 °F to 185 °F]
(compensated)
0 °C to 50 °C [32 °F to 120 °F]
(compensated)
Total error band
as low as ±0.25 %FSS depending on
pressure range (after auto zero)
±1 %FSS to ±3 %FSS
depending on pressure range
Accuracy
±0.1 %FSS BFSL
±0.25 %FSS BFSL
Mounting options
DIP, SMT
DIP, SIP, SMT
RSC Series
Ultra-Low
Pressure Sensors
ASDX Series
Signal conditioning
amplified
Pressure range
±5 inH2O, ±10 inH2O
Device type
differential, bidirectional gage
Output
analog (Vdc), digital (I2C or SPI)
Calibrated
yes
Temperature compensated
yes
Operating temperature range
0 °C to 85 °C [32 °F to 185 °F]
(compensated)
Total error band
±2.0 %FSS max.
Accuracy
-
Mounting options
DIP
HSC Series
Ultra-Low
Pressure Sensors
TruStability™
TruStability™
Signal conditioning
amplified
unamplified
Pressure range
±1.6 mbar to ±40 mbar |
±160 Pa to ±4 kPa |
±0.5 inH2O to ±30 inH2O
±2.5 mbar to ±40 mbar |
±250 Pa to ±4 kPa |
±1 inH2O to ±30 inH2O
Device type
differential, gage
differential, gage
Output
analog (Vdc) or digital (I C or SPI)
mV
Calibrated
yes
no
Temperature compensated
yes
no
Operating temperature range
-20 °C to 85 °C [-4 °F to 185 °F]
(compensated)
-40 °C to 85 °C [-40 °F to 185 °F]
Total error band
±2 %FSS to ±5 %FSS
depending on pressure range
-
Accuracy
±0.25 %FSS BFSL
±0.25% FSS BFSL
Mounting options
DIP, SIP, SMT
DIP, SIP, SMT
SSC Series
NSC Series
2
Ultra-Low
Pressure Sensors
SCXL Series
SDX005IND4
SDX010IND4
SXL Series
Signal conditioning
unamplified
unamplified
unamplified
Pressure range
4 inH2O to 10 inH2O
±5 inH2O to ±10 inH2O
±10 inH2O
Device type
differential, gage
differential, gage
differential, gage
Output
mV
mV
mV
Calibrated
yes
yes
no
Temperature compensated
yes
yes
no
Operating temperature range
0 °C to 50 °C [32 °F to 122 °F]
(compensated)
0 °C to 50 °C [32 °F to 122 °F]
(compensated)
0 °C to 50 °C [32 °F to 122 °F]
Total error band
-
-
-
Accuracy
linearity and hysteresis 0.2% typ.
linearity and hysteresis 0.2% typ.
linearity and hysteresis 0.2% typ.
Mounting options
SIP
DIP
SIP
sensing.honeywell.com 3
Low Pressure
Sensors
TruStability™ RSC Series
TruStability™ HSC Series
TruStability™ SSC Series
Signal conditioning
amplified
amplified
amplified
Pressure range
±60 mbar to ±10 bar |
±6 kPa to ±1 MPa |
±1 psi to ±150 psi
±60 mbar to ±10 bar |
±6 kPa to ±1 MPa |
±1 psi to ±150 psi
±60 mbar to ±10 bar |
±6 kPa to ±1 MPa |
±1 psi to ±150 psi
Device type
absolute, differential, gage
absolute, differential, gage
absolute, differential, gage
Output
24-bit digital (SPI)
analog (Vdc) or digital (I C or SPI)
analog (Vdc) or digital (I2C or SPI)
Calibrated
yes
yes
yes
2
Compensated
yes
yes
yes
Operating temperature range
-40 °C to 85 °C [-40 °F to 185 °F]
(compensated)
0 °C to 50 °C [32 °F to 122 °F]
(compensated)
-20 °C to 85 °C [-4 °F to 185 °F]
(compensated)
Total error band
as low as ±0.25 %FSS depending on
pressure range (after auto zero)
±1 %FSS
±2 %FSS
Accuracy
±0.1 %FSS BFSL
±0.25 %FSS BFSL
±0.25 %FSS BFSL
Mounting options
DIP, SMT
DIP, SIP, SMT
DIP, SIP, SMT
Basic ABP Series
Basic TBP Series
Basic NBP Series
Signal conditioning
amplified
unamplified
unamplified
Pressure range
60 mbar to 10 bar |
6 kPa to 1 MPa |
1 psi to 150 psi
60 mbar to 10 bar |
6 kPa to 1 MPa |
1 psi to 150 psi
60 mbar to 10 bar |
6 kPa to 1 MPa |
1 psi to 150 psi
Device type
gage, differential
gage
gage, absolute
Output
digital (I2C, SPI) or ratiometric analog
mV
mV
Calibrated
yes
yes
no
Compensated
yes
yes
no
Operating temperature range
0 °C to 50 °C [32 °F to 122 °F]
(compensated)
0 °C to 85 °C [32 °F to 185 °F]
(compensated)
40 °C to 125 °C [-40 °F to 257 °F]
Total error band
±1.5 %FSS
-
-
Accuracy
±0.25 %FSS BFSL
±0.25 %FSS
±0.25 %FSS
Mounting options
DIP, leadless SMT, SMT
DIP, leadless SMT, SMT
DIP, leadless SMT, SMT
Low Pressure
Sensors
4 sensing.honeywell.com
Low Pressure
Sensors
TruStability™ TSC Series
TruStability™ NSC Series
Signal conditioning
unamplified
unamplified
Pressure range
±60 mbar to ±10 bar |
±6 kPa to ±1 MPa |
±1 psi to ±150 psi
±60 mbar to ±10 bar |
±6 kPa to ±1 MPa |
±1 psi to ±150 psi
Device type
differential, gage
absolute, differential, gage
Output
mV
mV
Calibrated
yes
no
Compensated
yes
no
Operating temperature range
0 °C to 85 °C [32 °F to 185 °F]
(compensated)
40 °C to 85 °C [-40 °F to 185 °F]
Total error band
-
-
Accuracy
0.25 %FSS BFSL
0.25 %FSS BFSL
Mounting options
DIP, SIP, SMT
DIP, SIP, SMT
Low Pressure
Sensors
24PC Series
26PC Series
ASDX Series
Signal conditioning
unamplified
unamplified
amplified
Pressure range
0.5 psi to 250 psi (SIP, DIP)
1 psi to 15 psi (SMT)
1 psi to 250 psi (SIP, DIP)
1 psi to 15 psi (SMT)
1 psi to 100 psi
Device type
absolute, differential, wet-wet differential,
gage
differential, wet-wet differential, gage
absolute, differential, gage, bidirectional
Output
mV
mV
analog (Vdc), digital (I2C or SPI)
Calibrated
no
yes
yes
Compensated
no
yes
yes
Operating temperature range
-40 °C to 85 °C [-40 °F to 185 °F]
0 °C to 50 °C [32 °F to 122 °F]
(compensated)
0 °C to 85 °C [32 °F to 185 °F]
(compensated)
Total error band
-
-
±2.0% FSS max.
Accuracy
linearity & hysteresis 0.5% typ.
linearity & hysteresis 0.25% typ.
-
Mounting options
DIP, SIP, SMT
DIP, SIP, SMT
DIP
sensing.honeywell.com 5
Low Pressure
Sensors
Signal conditioning
SCX Series
SDX Series
unamplified
unamplified
Pressure range
1 psi to 150 psi
1 psi to 100 psi
Device type
absolute, differential, gage
absolute, differential, gage
Output
mV
mV
Calibrated
yes
yes
Compensated
yes
yes
Operating temperature range
0 °C to 70 °C [32 °F to 158 °F]
(compensated)
0 °C to 50 °C [32 °F to 122 °F]
(compensated)
Total error band
-
-
Accuracy
linearity and hysteresis 0.1% typ.
linearity and hysteresis 0.25% typ.
Mounting options
SIP
DIP
Low Pressure –
Flow Through Sensors
24PC Flow-Through Series
26PC Flow-Through Series
Signal conditioning
unamplified
unamplified
Pressure range
1 psi to 100 psi
1 psi to 100 psi
Device type
flow-through gage
flow-through gage
Output
mV
mV
Calibrated
no
yes
Compensated
no
yes
Operating temperature range
-40 °C to 85 °C [-40 °F to 185 °F]
0 °C to 50 °C [32 °F to 122 °F]
(compensated)
Total error band
-
-
Accuracy
linearity and hysteresis 0.75% typ.
linearity and hysteresis 0.75% typ.
Mounting options
SIP, DIP
SIP, DIP
6 sensing.honeywell.com
eliminating the need to service or
replace the sensor during its application
life. Industry-leading Total Error Band
provides the sensor’s true accuracy over
a compensated temperature range of 0
°C to 50 °C [32 °F to 122 °F], eliminating
individual sensor testing and calibration
(which can increase manufacturing time
and process) supporting system accuracy
and warranty requirements, helping
optimize system uptime, and providing
excellent sensor interchangeability.
Industry-leading accuracy reduces
software needed to correct system
inaccuracies, minimizing system design
time, supporting system accuracy and
warranty requirements, and helping
to optimize system uptime. High burst
pressures allow the sensor to endure a
wide range of conditions while maintaining
a high level of sensitivity which measures
even the smallest change in pressure,
simplifying the design process. High
working pressure ranges allow the sensors
to be used continuously well above the
calibrated pressure range. Modular,
flexible design with many package styles
(with the same industry-leading stability),
pressure ports, and options simplify
integration into the device manufacturer’s
application. Onboard signal conditioning
typically allows for the removal of signal
conditioning components from the PCB,
reducing costs and simplifying production
processes. Meets IPC/JEDEC J-STD020D.1 Moisture Sensitivity Level 1
requirements which allows the customer
to avoid the thermal and mechanical
damage during solder reflow attachment
and/or repair that lesser rated products
would incur, and allows unlimited floor life
when stored as specified (