MICRO SWITCH™ Cable-Pull Safety Switches
CPS Series
004785
Issue 2
Datasheet
FEATURES
DESCRIPTION
Honeywell’s MICRO SWITCH™ CPS Series Cable-Pull Safety
Switches provide a readily accessible emergency stop signal,
a cost-effective means compared to using multiple emergency
stop push-buttons. The CPS Series Cable Pull Safety Switch’s
internal mechanism latches on both slackened cable (push) and
pulled cable.
The 1CPS is intended for use in applications where the cable
span is 76 m [250 ft] or shorter. It is an economical solution for
shorter runs or zone protection typical to automated systems.
The 2CPS Series is intended for use in very long cable runs of
152 m [500 ft] or shorter, such as long conveyor lines found in
warehouses.
A line in the midpoint of the cable tension window indicates
proper cable tension, providing easy set-up. The direct opening
switch contacts are held closed when the actuating cable is
under proper tension and the reset knob is set to the RUN
position. When the actuating cable is pulled, slackened, or
broken, a cam positively opens the NC (Normally Closed) switch
contacts. The snap-action operation causes the switch contacts
to change state and mechanically latch almost simultaneously
when the cable is pulled, slackened, or broken. The NC
switch contacts remain open until the CPS is reset by properly
tensioning the cable and manually rotating the reset knob.
When the direct opening switch contacts open, the auxiliary
contacts also actuate (open contacts close). The auxiliary
contacts are electrically isolated from the direct-opening switch
contacts. These NO (Normally Open) contacts may be used for
monitoring or signaling.
• Direct opening action of NC (Normally Closed) contacts
• 2CPS: 2NO/2NC, 1NO/3NC,, or 4NC contact configurations
• 1CPS: 1NO/1NC, 2NO/2NC, 1NO/3NC, or 4NC contact
configurations
• Typical cable span of 76 m [250 ft] in an environment with
a temperature change of ±17 °C [±30 °F]. Longer spans are
possible depending upon temperature change and installation
• Choice of three actuator configurations (2CPS)
• Removable contact block version available (2CPS)
• J-hook turnbuckle included (2CPS)
• Large wiring cavity with straight-through wiring
• Models avaliable without broken cable, slack-cable detection
• 24 Vdc or 120 Vac bright, multi-cluster high-intensity LED
status indicator light available on 2CPS. Single LED on 1CPS
• Gold-plated contacts are standard on 2CPS, available on
1CPS
• Electrostatic, epoxy-coated, die-cast zinc housing
• Optional hardware packets available
POTENTIAL INDUSTRIAL APPLICATIONS
• Long conveyor systems found in warehouses and distribution
centers
• Conveyor systems with a high amount of vibration
• Conveyor systems that experience wide temperature swings
• Long conveyor systems where easy-through wiring, or highly
visible trip status, is required
• Perimeter guarding in hose-down conditions
• Packaging equipment
• Assembly lines
VALUE TO CUSTOMERS
• Cost-effective means of providing an emergency stop signal
compared to multiple emergency stop push buttons
• Capability enhances productivity by minimizing nuisance stops
due to variations in temperature, stretch of cable over time, or
other application variables
• Direct opening of normally closed contacts when cable is
actuated
DIFFERENTIATION
• Internal mechanism latches on both slackened cable (push)
and pulled cable
PORTFOLIO
The CPS Series is the largest switch in Honeywell’s MICRO
SWITCH™ line of safety switches. For more details on the
extensive line of Honeywell safety switches, click here.
Sensing and Productivity Solutions
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Table 1. Specifications
Characteristic
Parameter
Description
cable-pull safety switches
Switching options
1NO/1NC direct acting
2NO/2NC direct acting
1NO/3NC direct acting
4NC direct acting
Sealing
IP67, NEMA 1, 4, 12, 13
Contacts
silver, gold plated over silver
Conduit/Connectors
1/2 NPT, PG 13.5, 20 mm, PF 1/2; Brad Harrison 10-pin conductor
Force to maintain actuation shaft
2CPS: 25 lb*
Actuation shaft operating force
2CPS: 40 lb*
Operating temperature
-40 °C to 80 °C [-40 °F to 176 °F]
Storage temperature
1CPS: -40 °C to 85 °C [-40 °F to 185 °F]
Mechanical endurance
1 million operations
Rated thermal current (Ith)
10 A
Rated impulse withstand (Uimp)
2500 V
Rated insulation voltage (Ui)
300 V
Useable gold-plated current
1 mA to 50 mA, 60 Vdc max./125 Vdc max.
Pollution degree
3
Conditional short circuit current
1000 A
Short circuit protective device
(type/maximum rating)
Class J fuse (10 A/600 V)
Shock
15 g per IEC 68-2-27
Vibration
10 Hz to 500 Hz, 5 g per IEC 68-2-6
Approvals
UL, CSA, CE, SIL
Standards
• UL Listed per File E37138 against UL508
• CSA Certified per File 57323 against CSA C22.2 No. 14
• CE mark: The CPS complies with Low Voltage Directive 2006/95/EC; Machinery Directive 2006/42/
EC only as the directives relate to the components being used in a safety function; EN 60947-1; EN
60947-5-1; EN 60947-5-5
• SIL: MCTF (Mechanical Life): >1,000,000 cycles with single-sided confidence limit of 100 %.
MCTF (Electrical Life): >25,000 cycles with single-sided confidence limit of 87.5 %.
Highest SIL Capability: SIL3 (HFT:1), IEC 61508-2: 2010. Proof Test Interval: 1 Year
* Incline measures, and not typical for manual trip
Table 2. Electrical Ratings
ac
dc
A300
Ue
AC15
Ie
Q300
Ue
DC13
Ie
Volts
Amps
Volts
Amps
–
–
24
2.8
120
6
125
0.55
240
3
250
0.27
Ith = 10 A
2
sensing.honeywell.com
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Figure 1. 1CPS Product Nomenclature and Order Guide
1CPS
Switch Type
1CPS Series
Single-Head
Cable-Pull
Safety Switch
A
1
A
-N
Conduit
Basic Switch
Code
Indicator-Pilot
Light Code
Without
Broken
Cable
Detection
1NO/1NC direct acting
Switch 1: 1NO/1NC
Switch 2: None
A
1/2 NPT
1
B
PG 13.5
2
C
20 mm
3
2NO/2NC direct acting
Switch 1: 1NO/1NC
Switch 2: 1NO/1NC
1NO/3NC direct acting
Switch 1: 1NO/1NC
Switch 2: 2NC
D
PF 1/2
4
4NC direct acting
Switch 1: 2NC
Switch 2: 2NC
5
6
7
8
1NO/1NC direct acting, gold contacts
Switch 1: 1NO/1NC
Switch 2: None
2NO/2NC direct acting, gold contacts
Switch 1: 1NO/1NC
Switch 2: 1NO/1NC
1NO/3NC direct acting, gold contacts
Switch 1: 1NO/1NC
Switch 2: 2NC
A
24 Vdc LED
B
120 Vac LED
4NC direct acting, gold contacts
Switch 1: 2NC
Switch 2: 2NC
NOTE: Not all combinations of model code are available.
Please contact your Honeywell provider/representative for assistance.
Figure 2. 2CPS Product Nomenclature and Order Guide
2CPS
A
1
A
1
A
Conduit
Contact
Mounting Code
Basic Switch
Code
Actuation
Code
Indicator-Pilot
Light Code
A
1/2 NPT
1
Standard: contact
block mounted
to housing
A
2NO/2NC, direct acting
Switch 1: 1NO/1NC
Switch 2: 1NO/1NC
1
Maintained,
both sides
A
24 Vdc LED
cluster
B
PG 13.5
2
Removeable:
contact blocks
with receptacles
B
1NO/3NC, direct acting
Switch 1: 1NO/1NC
Switch 2: 2NC
2
Maintained, left side
No actuation, right side
B
120 Vac LED
cluster
C
20 mm
D
4NC, direct acting
Switch 1: 2NC
Switch 2: 2NC
3
Maintained, right side
No actuation, left side
D
PF 1/2
4
Maintained, both sides
w/o broken cable detection
5
Maintained, left side
No actuation, right side
w/o broken cable detection
61
Maintained, right side
No actuation, left side
w/o broken cable detection
Switch Type
2CPS Series
Dual-Head
Cable-Pull
Safety Switch
NOTE: Not all combinations of model code are available.
Please contact your Honeywell provider/representative for assistance.
1
Not valid on 4NC switches
Sensing and Productivity Solutions
3
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
TEMPERATURE-SPAN DISTANCE APPLICATION
INFORMATION
Cable-Pull switches featuring broken cable detection require pretensioning in order to enable the RUN condition.
The relative expansion or contraction of the steel actuating cable
when the ambient temperature increases or decreases must be
taken into account when pre-tensioning a cable pull switch.
Table 3. Circuitry Charts
Circuitry
Chart
1NO/1NC
2NO/2NC
The change in cable length with change in temperature can cause
significant nuisance shut downs on longer runs.
Install the system when the temperature is at the mid point of the
extremes. If a warehouse has a low temperature of 15.6 °C [60 °F]
and a high of 32.2 °C [90 °F], set up the system at the midpoint
23.9 °C [75 °F].
Use an endspring or another CPS at the opposite end of the
cable span to double the temperature tolerance and to meet the
requirements of EN 418.
1NO/3NC
4NC
Figure 3. Total Temperature Variation vs. Cable Span
Distance
1NO/1NC
1NO/3NC
2NO/2NC
4NC
Table 4. 1CPS Contact Blocks
= grounding screw
4
sensing.honeywell.com
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Table 5. 2CPS Contact Blocks
Removable Contact Blocks with
Heavy-Duty Wiring Receptacles
Contact Block Mounted to Housing
A = grounding screw
A = grounding screw
2NO/2NC
2NO/2NC
1NO/3NC
1NO/3NC
4NC
Sensing and Productivity Solutions
5
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Conduit
Switching
1CPSA1
1/2 in NPT
1NO/1NC
1CPSA1A
1/2 in NPT
1NO/1NC
1CPSA1B
1/2 in NPT
1NO/1NC
1CPSA5
1/2 in NPT
1NO/1NC
1CPSC1
20 mm
1NO/1NC
Bar Chart
¢ Contact Closed | ¨ Contact Open
Contact
Material
Pilot Light
120 Vac LED
Catalog
Listing
Pilot Light
24 Vdc LED
Table 6. 1CPS With Broken Cable Detection Order Guide
silver alloy
12,7
[0.5]
Left 21-22
Switch 13-14
9,9
[0.39]
9,9
[0.39]
7,9
3,8
3,8
7,9
12,7
[0.31] [0.15] [0.15] [0.31]
[0.5]
0
Slackened
cable
Proper
cable
tension
Pulled
cable
silver alloy
Notes
–
–
ü
silver alloy
ü
–
gold-plated
–
silver alloy
–
1CPSC1A
20 mm
1NO/1NC
1CPSC5
20 mm
1NO/1NC
gold-plated
–
1CPSA2
1/2 in NPT
2NO/2NC
silver alloy
–
1CPSA2A
1/2 in NPT
2NO/2NC
silver alloy
1CPSA2B
1/2 in NPT
2NO/2NC
silver alloy
1CPSA6
1/2 in NPT
2NO/2NC
1CPSA6A
1/2 in NPT
2NO/2NC
1CPSA6B
1/2 in NPT
2NO/2NC
1CPSC2
20 mm
2NO/2NC
Left
Switch
Right
Switch
12,7
[0.5]
21-22
13-14
21-22
13-14
9,9
[0.39]
0
7,9
3,8
3,8
7,9
[0.31] [0.15] [0.15] [0.31]
9,9
[0.39]
silver alloy
12,7
[0.5]
–
ü
ü
gold-plated
gold-plated
–
ü
ü
silver alloy
Proper
cable
tension
Pulled
cable
–
–
1CPSC2A
20 mm
2NO/2NC
1CPSC2B
20 mm
2NO/2NC
silver alloy
1CPSC6
20 mm
2NO/2NC
gold-plated
1CPSC6A
20 mm
2NO/2NC
gold-plated
1CPSA3
1/2 in NPT
1NO/3NC
silver alloy
1CPSA3A
1/2 in NPT
1NO/3NC
silver alloy
ü
–
1CPSA3A-F01
1/2 in NPT
1NO/3NC
silver alloy
ü
10-pin Brad Harrison connector;
actuator to right
silver alloy
ü
10-pin Brad Harrison connector;
actuator to left
Left
Switch
Right
Switch
12,7
[0.5]
21-22
13-14
11-12
21-22
0
9,9
[0.39]
7,9
3,8
3,8
7,9
[0.31] [0.15] [0.15] [0.31]
9,9
[0.39]
silver alloy
–
–
gold-plated
Slackened
cable
–
ü
–
ü
ü
–
–
–
ü
–
12,7
[0.5]
1CPSA3A-F02
1/2 in NPT
1NO/3NC
1CPSA3B
1/2 in NPT
1NO/3NC
1CPSA7
1/2 in NPT
1NO/3NC
1CPSC3
20 mm
1NO/3NC
1CPSC3A
20 mm
1NO/3NC
silver alloy
1CPSC7
20 mm
1NO/3NC
gold-plated
–
1CPSA4
1/2 in NPT
4NC
silver alloy
–
1CPSA4B
1/2 in NPT
4NC
1CPSA8
1/2 in NPT
4NC
1CPSC4
20 mm
4NC
1CPSC8
6
20 mm
sensing.honeywell.com
4NC
Slackened
cable
Left
Switch
Right
Switch
12,7
[0.5]
11-12
21-22
11-12
21-22
9,9
[0.39]
silver alloy
Proper
cable
tension
0
7,9
3,8
3,8
7,9
[0.31] [0.15] [0.15] [0.31]
Slackened
cable
Proper
cable
tension
gold-plated
Pulled
cable
9,9
[0.39]
Pulled
cable
ü
–
silver alloy
12,7
[0.5]
silver alloy
–
–
–
ü
ü
–
gold-plated
–
silver alloy
–
gold-plated
–
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
1CPSA1-N
Conduit
Switching
1/2 in NPT
1NO/1NC
Bar Chart
¢ Contact Closed | ¨ Contact Open
7,9
[0.31]
0
1CPSA1A-N
1/2 in NPT
1NO/1NC
1CPSA1B-N
1/2 in NPT
1NO/1NC
1CPSA2-N
1/2 in NPT
2NO/2NC
1CPSA2B-N
1/2 in NPT
2NO/2NC
9,9
[0.39]
silver alloy
silver alloy
Pulled
cable
21-22
13-14
21-22
13-14
0
7,9
[0.31]
9,9
[0.39]
Notes
–
12,7
[0.5]
Left 21-22
Switch 13-14
Left
Switch
Right
Switch
Contact
Material
Pilot Light
120 Vac LED
Catalog
Listing
Pilot Light
24 Vdc LED
Table 7. 1CPS Without Broken Cable Detection Order Guide
silver alloy
–
ü
ü
silver alloy
–
–
12,7
[0.5]
silver alloy
ü
–
silver alloy
ü
–
Pulled
cable
9,9
[0.39]
1CPSA4B-N
1/2 in NPT
4NC
Left
Switch
Right
Switch
11-12
21-22
11-12
21-22
0
7,9
[0.31]
12,7
[0.5]
Pulled
cable
Sensing and Productivity Solutions
7
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Pilot Light LED
2CPSA1A1
1/2 in NPT
2NO/2NC
ü
Both
2CPSA1A1A
1/2 in NPT
2NO/2NC
ü
Both
24
Vdcdc
2CPSA1A1A-FW
1/2 in NPT
2NO/2NC
ü
Both
24 Vdc
2CPSA1A1B
1/2 in NPT
2NO/2NC
ü
Both
120 Vac
2CPSA1A2
1/2 in NPT
2NO/2NC
ü
Left only
2CPSA1A2A
1/2 in NPT
2NO/2NC
ü
Left only
24 Vdc
2CPSA1A2A-FW
1/2 in NPT
2NO/2NC
ü
Left only
24 Vdc
2CPSA1A2B
1/2 in NPT
2NO/2NC
ü
Left only
120 Vac
2CPSA1A3
1/2 in NPT
2NO/2NC
ü
Right only
2CPSA1A3A
1/2 in NPT
2NO/2NC
ü
Right only 24 Vdc
2CPSA1A3A-FW
1/2 in NPT
2NO/2NC
ü
Right only 24 Vdc
ü
Right only 120 Vac
Catalog Listing
2CPSA1A3B
1/2 in NPT
2NO/2NC
2CPSA2A1
1/2 in NPT
2NO/2NC
2CPSA2A1A
1/2 in NPT
2NO/2NC
2CPSA2A1B
1/2 in NPT
2NO/2NC
2CPSA2A2
1/2 in NPT
2CPSA2A2A
1/2 in NPT
2CPSA2A2B
Bar Chart
¢ Contact Closed
¨ Contact Open
Left
Switch
Right
Switch
12,7
[0.5]
21-22
13-14
21-22
13-14
9,9
[0.39]
0
7,9
3,8
3,8
7,9
[0.31] [0.15] [0.15] [0.31]
9,9
[0.39]
12,7
[0.5]
Actuation
Switching
Removeable
Contact Block
Conduit
Standard
Contact Block
Table 8. 2CPS With Broken Cable Detection and Silver Alloy Contacts Order Guide
ü
Both
ü
Both
24 Vdc
ü
Both
120 Vac
2NO/2NC
ü
Left only
2NO/2NC
ü
Left only
24 Vdc
1/2 in NPT
2NO/2NC
ü
Left only
120 Vac
2CPSA2A3
1/2 in NPT
2NO/2NC
ü
Right only
2CPSA2A3A
1/2 in NPT
2NO/2NC
ü
Right only 24 Vdc
2CPSA2A3B
1/2 in NPT
2NO/2NC
ü
Right only 120 Vac
2CPSC1A1
20 mm
2NO/2NC
ü
Both
2CPSC1A1A
20 mm
2NO/2NC
ü
Both
2CPSC1A2
20 mm
2NO/2NC
ü
Left only
2CPSC1A2A
20 mm
2NO/2NC
ü
Left only
2CPSC1A3
20 mm
2NO/2NC
ü
Right only
2CPSC1A3A
20 mm
2NO/2NC
ü
Right only 24 Vdc
2CPSC2A1A
20 mm
2NO/2NC
8
sensing.honeywell.com
Slackened
cable
Proper
cable
tension
Pulled
cable
ü
Both
24 Vdc
24 Vdc
24 Vdc
Notes
10-pin Brad
Harrison
connector
10-pin Brad
Harrison
connector
10-pin Brad
Harrison
connector
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Pilot Light LED
2CPSA1B1
1/2 in NPT
1NO/3NC
ü
Both
2CPSA1B1A
1/2 in NPT
1NO/3NC
ü
Both
24 Vdc
2CPSA1B1A-F01 1/2 in NPT
1NO/3NC
ü
Both
24 Vdc
2CPSA1B1B
1/2 in NPT
1NO/3NC
ü
Both
120 Vac
2CPSA1B2
1/2 in NPT
1NO/3NC
ü
Left only
120 Vac
2CPSA1B2A
1/2 in NPT
1NO/3NC
ü
Left only
24 Vdc
ü
Left only
24 Vdc
ü
Left only
120 Vac
ü
Right only
ü
Right only 24 Vdc
Right only 24 Vdc
Catalog Listing
Bar Chart
¢ Contact Closed
¨ Contact Open
12,7
[0.5]
21-22
13-14
11-12
21-22
9,9
[0.39]
0
7,9
3,8
3,8
7,9
[0.31] [0.15] [0.15] [0.31]
9,9
[0.39]
12,7
[0.5]
Actuation
Switching
Removeable
Contact Block
Conduit
Standard
Contact Block
Table 8. 2CPS With Broken Cable Detection and Silver Alloy Contacts Order Guide, continued
2CPSA1B2A-F01 1/2 in NPT
1NO/3NC
2CPSA1B2B
1/2 in NPT
1NO/3NC
2CPSA1B3
1/2 in NPT
1NO/3NC
2CPSA1B3A
1/2 in NPT
1NO/3NC
2CPSA1B3A-F01 1/2 in NPT
1NO/3NC
ü
2CPSA1B3B
1/2 in NPT
1NO/3NC
ü
2CPSA2B1
1/2 in NPT
1NO/3NC
ü
Both
2CPSA2B1A
1/2 in NPT
1NO/3NC
ü
Both
24 Vdc
2CPSA2B1B
1/2 in NPT
1NO/3NC
ü
Both
120 Vac
Both
24 Vdc
2CPSC1D1A
20 mm
4NC
Left
Switch
Right
Switch
Slackened
cable
Left
Switch
Right
Switch
12,7
[0.5]
11-12
21-22
11-12
21-22
Proper
cable
tension
Pulled
cable
Notes
10-pin Brad
Harrison
connector
10-pin Brad
Harrison
connector
10-pin Brad
Harrison
connector
Right only 120 Vac
0
9,9
[0.39]
7,9
3,8
3,8
7,9
12,7
[0.31] [0.15] [0.15] [0.31]
[0.5]
9,9
[0.39]
Slackened
cable
ü
Proper
cable
tension
Pulled
cable
Sensing and Productivity Solutions
9
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
2CPSA1A4B
1/2 in NPT
2NO/2NC
2CPSA1A5B
1/2 in NPT
2NO/2NC
2CPSA1A6B
1/2 in NPT
2NO/2NC
2CPSA2A4A
1/2 in NPT
2NO/2NC
2CPSA2A4B
1/2 in NPT
2NO/2NC
2CPSC1A4-F02
20 mm
2NO/2NC
10
sensing.honeywell.com
Left
Switch
Right
Switch
21-22
13-14
21-22
13-14
0
7,9
[0.31]
9,9
[0.39]
Pulled
cable
12,7
[0.5]
Pilot Light LED
2NO/2NC
Actuation
1/2 in NPT
Bar Chart
¢ Contact Closed
¨ Contact Open
Removeable
Contact Block
Switching
2CPSA1A4
Catalog Listing
Standard
Contact Block
Conduit
Table 9. 2CPS Without Broken Cable Detection and With Silver Alloy Contacts Order Guide
ü
Both
ü
Both
120 Vac
ü
Left only
120 Vac
ü
Right only
120 Vac
ü
Both
24 Vdc
ü
Both
120 Vac
ü
Both
Notes
No turnbuckles included
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Figure 4. 1CPS Dimensional Drawing
172,72 mm [6.8 in]
6,6 mm
[0.26 in]
88,9 mm
[3.5 in]
152,4 mm [6.0 in]
Indicator version only
81,28 mm [3.2 in]
33,02 mm
[1.3 in]
12,7 mm
[0.5 in]
99,1 mm 76,2 mm
[3.9 in]
[3.0 in]
53,34 mm
[2.1 in]
4 X Ø 7,37 mm
[4 X Ø 0.29 in]
117,25 mm [4.616 in]
approx. at full travel
56,8 mm
[2.24 in]
65,2 mm
[2.57 in]
50,82 mm
[2.001 in]
3X 25,4 mm
[3X 1.0 in]
25,4 mm
[1.0 in]
3X conduit thread
4X mounting pad
Sensing and Productivity Solutions
11
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Figure 5. 2CPS Dimensional Drawing
40,39 mm
[1.59 in]
66,8 mm
[2.63 in]
84,07 mm
[3.31 in]
92,89 mm
[3.66 in]
323,85 mm [12.75 in] approx. at actuation
152,4 mm [6.0 in]
Manual reset button
19,05 mm
[0.75 in]
52,07 mm
[2.05 in]
12,7 mm
[0.5 in]
40,39 mm
[1.59 in]
2X 7,11 mm [0.28 in]
18,29 mm [0.72 in]
34,93 mm [1.375 in]
152,4 mm
[6 in]
2X 7,11 mm
[0.28 in]
2X 9,14 mm [0.36 in]
81,3 mm
[3.2 in]
2X mounting pad
104,78 mm [4.125 in]
Indicator version only
2X 31,75 mm [1.25 in]
12,7 mm [0.5 in]
57,15 mm
[2.25 in]
139,7 mm [5.50 in]
3X conduit thread
2X mounting pad
2X 6,9 mm [0.27 in]
3X 12,46 mm [0.845 in]
12
sensing.honeywell.com
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Figure 6. 1CPS Application Information
Figure 7. 2CPS Application Information
Sensing and Productivity Solutions
13
MICRO SWITCH™ Cable-Pull Safety Switches, CPS Series
Table 10. Accessories/Hardware Packets
Catalog Listing
Accessory
CLSZC1
Cable - 7,6 m [25 ft] length
CLSZC2
Cable - 15,2 m [50 ft] length
CLSZC3
Cable - 30,5 m [100 ft] length
CLSZC4
Cable - 45,7 m [150 ft] length
CLSZC5
Cable - 61 m [200 ft] length
CLSZC7
Cable - 76,2 m [250 ft] length
CLSZTC
(2) Thimbles
(2) Low-profile duplex cable clamps
CLSZ1S
(1) Draw-bar endspring
CLSZK1
(1) J-hook turnbuckle with lock nuts
(2) Thimbles
(2) Low-profile duplex cable clamps
(16) Sets of cable supports [(16) 1/4-20 eye bolts, (32) 1/4-20 nuts, (32) flat washers, (16) lock washers]
CPSZ1E
M6 x 1 x 60 mm eyebolt
CPSZ1S
(1) Draw-bar endspring
CPSZK1
(1) J-hook turnbuckle with lock nuts
(2) Thimbles
(2) Low-profile duplex cable clamps
(16) Sets of cable supports [(16) 1/4-20 eye bolts, (32) 1/4-20 nuts, (32) flat washers, (16) lock washers]
CPSZK2
European hardware packet
(1) J-hook turnbuckle with lock nuts
(2) Thimbles
(2) Stainless steel cable clamps
(16) Sets of cable supports [(16) 1/4-20 eye bolts, (32) 1/4-20 nuts, (32) flat washers, (16) lock washers]
CPSZTB
J-hook turnbuckle with lock nuts (included with 2CPS)
CPSLED24
Multi-cluster LED accessory - 24 Vdc (conduit mount)
CPSLED120
Multi-cluster LED accessory - 120 Vac (conduit mount)
CPS-BRACKET
Mounting bracket (to be used with 1CPS or 2CPS)
Figure 8. CPSLED Dimensional Drawing
14
sensing.honeywell.com
Figure 9. CPS-Bracket
m WARNING
ADDITIONAL MATERIALS
The following associated literature is available on the Honeywell
web site at sensing.honeywell.com:
•
•
•
•
•
•
Product line guide
Product part listing/nomenclature tree
Product range guide
CPS troubleshooting guide
Electromechanical safety switch product selection guide
Application note: MICRO SWITCH™ switches in conveyor
applications
RISK TO LIFE OR PROPERTY
Never use this product for an application involving serious risk
to life or property without ensuring that the system as a whole
has been designed to address the risks, and that this product
is properly rated and installed for the intended use within the
overall system.
Failure to comply with these instructions could result in
death or serious injury.
m WARNING
MISUSE OF DOCUMENTATION
•
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Warranty/Remedy
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifica-
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgement
or consult your local sales office for specific warranty details. If
warranted goods are returned to Honeywell during the period of
coverage, Honeywell will repair or replace, at its option, without
charge those items it finds defective. The foregoing is buyer’s
sole remedy and is in lieu of all other warranties, expressed
or implied, including those of merchantability and fitness for
a particular purpose. In no event shall Honeywell be liable for
consequential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
tions, pricing or name of the
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
nearest Authorized Distributor,
However, we assume no responsibility for its use.
contact your local sales office.
To learn more about Honeywell’s
products, call +1-815-235-6847
or 1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
Sensing and Productivity Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
004785-2-EN IL50 GLO
November 2015
© 2015 Honeywell International Inc. All rights reserved.