0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DE800-079A

DE800-079A

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    BOARD INTERFACE

  • 数据手册
  • 价格&库存
DE800-079A 数据手册
Oxymac50, DE800, Elecdit Oxygen Sensor Interface Boards DESCRIPTION The Oxymac 50, Elecdit and DE800 sensor interface boards are control and measurement devices for Honeywell’s range of dynamic, highly accurate oxygen sensors. The ability of these sensors to operate without any reference gas makes them ideal for potential applications such as combustion and environmental control. Honeywell oxygen sensors using zirconia-based sensing elements require external connection to an electronic measuring circuit to control sensor operation and signal processing. A heating element on the sensor produces the 700 °C [1292 °F] required for the ZrO2 to achieve its operational temperature. These interface boards supply the sensor with the necessary circuits to provide this control and processing, while also providing sensor calibration. The DE800 interface also includes the heater supply, while the Oxymac50 and Elecdit require an external heater power supply. FEATURES AND BENEFITS Provides the necessary circuits to control Honeywell oxygen sensors which removes the need to implement sensor control circuits within the customers’ equipment Functional testing and calibration in ambient air removes effects of barometric or application pressure PCB board format provides ease of mounting and calibration access Linear output of measured oxygen content in voltage or current format for a flexible interconnection Low power consumption for lower running costs Oxymac50 is a recently upgraded interface that offers similar performance to the Elecdit board but operates from a 24 Vdc power supply. The DE800 interface offers the features of the Oxymac50 but also contains the heating element power source. The Elecdit interface was developed for Industrial applications and offers a level of noise protection. It operates from a ±15 V supply. Oxymac50 and DE800 are the recommended interfaces for new applications. The interfaces are supplied ready for mounting into customers’ enclosures. Oxymac50 a 15-pin D type connector, DE800 has screw connector block and Elecdit has 2,5 mm x 2,5 mm [0.1 in x 0.1 in] pin connector. POTENTIAL APPLICATIONS Boiler combustion controls Aircraft oxygen generation systems Oxymac50, DE800, Elecdit Table 1. Technical Specifications Characteristic Measuring range Power source Other inputs Power consumption (interface) Outputs Accuracy Resolution Operating temperature Storage temperature Dimensions Mounting holes Connector 1 Oxymac50 DE800 0% to 25% oxygen (standard) 0% to 100% oxygen (option) +24 Vdc 20% +24 Vdc 20% calibration trigger, sensor calibration trigger, sensor pump, sense and common, pump, sense, common, test heater, test
DE800-079A 价格&库存

很抱歉,暂时无法提供与“DE800-079A”相匹配的价格&库存,您可以联系我们找货

免费人工找货