0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DTE6-2RN2

DTE6-2RN2

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    Switch; Limit Switch Actuator:top Roller Arm; Contact Configuration:dpdt; Contact Current Ac Max:10A...

  • 数据手册
  • 价格&库存
DTE6-2RN2 数据手册
MICRO SWITCH™ Medium-Duty Limit Switches E6/V6 Series Datasheet MICRO SWITCH™ E6/V6 Series Medium-Duty Limit Switches Honeywell MICRO SWITCH™ E6/V6 Series medium-duty limit switches are designed for a wide variety of indoor and outdoor applications. Typical applications include equipment for commercial, industrial, transportation, and agriculture industries. The electrostatic applied epoxy coating to the zinc housings enhance the durability of the product in most environments. The E6/V6 family of switches incorporates the Honeywell MICRO SWITCH™ BZ switch element which has the reliable snap-spring mechanism with more than 60 years of proven service. The sealed (actuators with boots) E6/V6 Series switches are preferred for applications where there could be exposure to liquid and/or particulate environments. The general purpose (actuators without boot seals) E6/V6 Series switches are ideal for applications where there will not be exposure to liquid or dust environments. The compact size of these limit switches permits installation where there is limited space available on equipment. Most SPDT (Single Pole Double Throw) E6/V6 catalog listings are certified to UL, CSA, and CE while the DPDT (Double Pole Double Throw) E6/V6 catalog listings are certified to UL and CSA. What makes our switches better? Designed with MICRO SWITCH™ BZ, BM, or DT basic switches to deliver precise switching of electrical and mechanical operating characteristics High capacity (22 A) available with BME6 Series switch Small footprint with easy access to wiring terminals Available in a configuration suited to the application with variety of actuators, circuitries, connectivities, and mounting options HIGH PERFORMANCE • DURABILITY CUSTOMIZATION • EASY TO INSTALL 2 sensing.honeywell.com Features and Benefits DESIGNED FOR DEMANDING ENVIRONMENTS AND APPLICATIONS MICRO SWITCH™ E6/V6 Series switches feature an electrostatic epoxy coated zinc housing for durability in most indoor and outdoor environments, and a wide variety of actuators to solve most application requirements. Side and flange mounting options RELIABLY HANDLES ELECTRICAL LOADS The E6/V6 Series are available with SPDT contacts with momentary or maintained action, or DPDT contacts with momentary action. These switches also offer goldplated switch contacts for logic-level circuits and silver alloy contacts for power duty circuits. The internal ground screw is provided to meet electrical codes as required. DESIGN FLEXIBILITY These limit switches are offered with multiple connectivity options: three different conduit offerings, four-pin “mini” style connector, pre-wired 16-gage fourconductor cable, pigtail with three-pin Deutsch connector. GLOBAL APPROVALS E6/V6 Series switches are UL, CSA, and CE certified for most SPDT catalog listings. The DPDT catalog listings are UL and CSA certified. LOW TEMPERATURE OPTIONS The E6/V6 Series’ standard temperature range is -32 °C to 71 °C [-25 °F to 160 °F] with an optional -40 °C [-40 °F] low temperature. sensing.honeywell.com 3 Figure 1. MICRO SWITCH™ E6 Side Mount and V6 Flange Mount with Features and Options Stainless steel roller Wide choice of actuators and operating characteristics Diaphragm boot seal for long life Single or double pole switches Multiple conduit options for ease of connectivity Rugged zinc housing and cover are phosphate treated and epoxy coated for environmental durability Popular 25,4 mm [1 in] mounting pattern Terminal screws of switch easily accessed with cover removed Captive cover screws (2) Internal ground screw provided in cover Cover with one-piece molded insulator seal Figure 1A. E6 Side mount with boot sealed actuator (typical) Wide choice of actuator styles and operating characteristics Hardened steel plunger for long life Rugged zinc housing and cover phosphate treated and electrostatic epoxy coated for environmental durability Single or double pole switches Multiple conduit options for ease of connectivity Terminal screws of switch easily accessed with cover removed Captive cover screws (2) Internal ground screw provided in cover Optional flange base mounting Cover with one-piece molded insulator seal Figure 1B. V6 Flange mount without boot sealed actuator (typical) 4 sensing.honeywell.com Potential Applications INDUSTRIAL • Packaging equipment (balers, door interlocks) • Air curtains (control of air movement) • Conveyors (diverters, gates) TRANSPORTATION • Construction machinery and equipment (door and panel interlocks) • Rail maintenance equipment (door and panel interlocks, position sensing) • Agricultural equipment (grain handling) Table 1. Specifications Characteristic Actuators Housing material Termination Sealing Switching options Mechanical endurance Electrical endurance Operating temperature Agency approvals Parameter top pin plunger (with and without boot seal) top roller plunger, parallel with long axis of switch (with and without boot seal) cross roller plunger, perpendicular with long axis of switch (with and without boot seal) manually operated (with boot seal) roller arm, adjustable (with and without boot seal) one-way roller lever (with boot seal) low-force rod lever (with and without boot seal) wobble (with boot seal) manual reset switches: top pin plunger, top roller plunger, adjustable roller arm, wobble electrostatic epoxy coated zinc die-cast see table 2 below actuator with boot seal: NEMA 1, 3, 4, IP66 actuator without seal boot: NEMA 1, IP40 SPDT (snap-action contacts, 1NO/1NC) SPDT-DB (double break snap-action contacts, 1NO/1NC) DPDT (snap-action contacts, 2NO/2NC) up to five million cycles for BZx6 and BMx6 switches; up to two million cycles for DTx6 switches up to 50K cycles at full rated load -32 °C to 71 °C [-25 °F to 160 °F] (standard) -40 °C to 71 °C [-40 °F to 160 °F] (optional low temperature) UL, CSA, CE Table 2. Terminations Catalog Listing Suffixes none Description 0.5 - 14 NPT conduit thread S 0.5 - 14 NPSM conduit thread M M20 - 1,5 mm conduit thread R four-pin “mini” style connector F1 305 mm [12 in] pigtail STOW-A, three conductor, 16-gage cable with three-pin Deutsch connector F3 914 mm [36 in] 16-gage, four-conductor STO, PVC jacketed cable sensing.honeywell.com 5 E6/V6 Series Table 3. Electrical Ratings Rating Code UL, CSA Rating CE Rating A 15 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac; 1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac; 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc EN60947-5-1, IEC60947-5-1 AC15, B300 B 10 A @ 125 Vac, 250 Vac 0.3 A @ 125 Vdc, 0.15 A @ 250 Vdc – C 15 A @125 Vac, 250 Vac or 480 Vac; 1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac; 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc EN60947-5-1, IEC60947-5-1 AC15, B300 D 8 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac; 1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac; 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc EN60947-5-1, IEC60947-5-1 AC15, B300 E 10 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac; 1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac; 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc EN60947-5-1, IEC60947-5-1 AC15, B300 F 15 A @125 Vac, 250 Vac or 480 Vac; 1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac; 1.0 A @ 125 Vdc, 0.5 A @ 250 Vdc EN60947-5-1, IEC60947-5-1 AC15, B300 G 22 A @125 Vac, 250 Vac or 480 Vac; 1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac; 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc – H 1A @ 125 Vac (Gold-plated contacts) IEC 61058-1 1A, 250 Vac Table 4. CE Electrical Rating, EN60947-5-1, IEC 60947-5-1 Designation & Category Vac Amps Make Amps Break Continuous Current (A) VA Rating Make VA Rating Break AC15, B300 120 30 3.0 5 3600 360 AC15, B300 240 15 1.5 5 3600 360 Table 5. Switching SPDT C 6 sensing.honeywell.com DPDT NC NO SPDT-DB C NC NO C NC NO NC NO NC NO MICRO SWITCH™ Medium-Duty Limit Switches PRODUCT NOMENCLATURE BZ E6 Switch Type Enclosure Type BZ Series Basic Switch SPDT, 15 A DT Series Basic Switch DPDT, 10 A BM Series Basic Switch SPDT, 22 A E6 Side mount V6 Flange mount — 2 R N Internal Basic Switch Construction Contact Plunger Type For use with “X” actuator, maintained contact2 (blank) 2 Standard 7 Special2 R Standard (Single-break) A Double-break (BZ basic switch only) N Q Actuator Modifications3 Additional Modifications 0.5-14 NPT conduit thread Seal boot Pin plunger No seal boot X Maintained contact with reset plunger2 C3 2 Adjustable roller lever F1 Pre-leaded, 3 ft cable, conduit area epoxy sealed 12-inch pigtail cable with 3-pin Deutsch connect. 4 Manual, palm button F3 Epoxy sealed, 3 ft of cable 7 #8 mounting screws F5 Epoxy sealed, 5 ft of cable 8 80 Roller plunger F6 Epoxy sealed, 6 ft of cable 18 Coil spring wobble stick FR Epoxy sealed, 4-pin “mini style” connector 28 One-way roller lever R 4-pin “mini style” connector 34 Low temp. S 1/4-14 NPSM conduit threads Rod lever M M20 x 1,5 mm conduit thread NOTE: 1. Not all combinations of model codes are available. Contact your Honeywell rep or distributor for assistance. 2. BZ Series only. 3. More than one actuator modification may be permissible. For example, BZE6-2RN8034 is a roller plunger with low temperature seals. (blank) 62 72 722 81 (blank) Gold-contact switch Cross roller plunger sensing.honeywell.com 7 E6/V6 Series Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. Operate Point mm [in] Operate Force N [oz] A, 2,50 to 6,67 43,66 ±0,76 15 A [9 to 24] [1.719 ±0.030] 1,98 [0.078] 5,56 [0.219] 0,05 [0.002] BZE6-2RN-F1 BZ, SPDT E, 2,50 to 6,67 43,66 ±0,76 10 A [9 to 24] [1.719 ±0.030] 1,98 [0.078] 5,56 [0.219] 0,05 [0.002] BZE6-2RN-F3 BZ, SPDT E, 2,50 to 6,67 43,66 ±0,76 10 A [9 to 24] [1.719 ±0.030] 1,98 [0.078] 5,56 [0.219] 0,05 [0.002] BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT, Double break BM, SPDT DT, DPDT BZ, SPDT BZ, SPDT DT, DPDT A, 15 A D, 8A A, 15 A A, 15 A A, 15 A H, 1A 43,66 ±0,76 [1.719 ±0.030] 43,66 ±0,76 [1.719 ±0.030] 43,66 ±0,76 [1.719 ±0.030] 43,66 ±0,76 [1.719 ±0.030] 43,66 ±0,76 [1.719 ±0.030] 43,66 ±0,76 [1.719 ±0.030] 1,98 [0.078] 1,98 [0.078] 1,98 [0.078] 1,98 [0.078] 1,98 [0.078] 1,98 [0.078] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] F, 2,50 to 6,67 43,66 ±0,76 15 A [9 to 24] [1.719 ±0.030] 1,98 [0.078] 5,56 [0.219] 0,05 [0.002] Recommended for dc applications G, 22 A B, 10 A A, 15 A A, 15 A B, 10 A 43,66 ±0,76 [1.719 ±0.030] 46,02 ±0,76 [1.812 ±0.030] 56,7 ±1,14 [2.232 ±0.045] 56,7 ±1,14 [2.232 ±0.045] 59,6 ±1,0 [2.345 ±0.040] 1,98 [0.078] 2,80 [0.110] 1,98 [0.078] 1,98 [0.078] 2,80 [0.110] 5,56 [0.219] 3,17 [0.125] 5,56 [0.219] 5,56 [0.219] 3,17 [0.125] 0,05 [0.002] 1,52 [0.060] 0,05 [0.002] 0,05 [0.002] 1,52 [0.060] Higher current ac applications Double pole applications DTE62RN8034-M DT, DPDT B, 5,56 to 13,3 59,6 ±1,0 10 A [20 to 48] [2.345 ±0.040] 2,80 [0.110] 3,17 [0.125] 1,52 [0.060] BZE6-2RN81 BZ, SPDT A, 2,50 to 6,67 56,7 ±1,14 15 A [9 to24] [2.232 ±0.045] 1,98 [0.078] 5,56 [0.219] 0,05 [0.002] BZE6-2RN-M BZE6-2RN-R BZE6-2RN-S BZE6-2RN7 Pin Plunger BZE6-2RN34 BZE6-2RN72 BZE6-2AN BME6-2RN DTE6-2RN BZE6-2RN80 BZE6-2RN8034 DTE6-2RN80 Inline Roller Plunger Cross Roller Plunger sensing.honeywell.com Switch type, Circuitry BZE6-2RN BZ, SPDT Catalog Listing 8 Electrical Rating [page 6] Table 6. Order Guide • E6 Series Switches, Side Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 7,23 to 16,4 [26 to 59] 2,50 to 6,67 [9 to24] 2,50 to 6,67 [9 to24] 5,56 to 13,3 [20 to 48] Comments 12 in. pigtail, 3 wire STO cable w/ Deutsch connector Epoxy sealed with 36 in. 4 wire STO cable M20-1,5 conduit thread 4-pin "mini" style connector 0.5-14 NPSM conduit thread #8 mounting screws Low temperature -40 °C [-40 °F] Gold-plated contacts Low temperature -40 °C [-40 °F] Double pole applications Low temp. -40 °C [-40 °F], M20 -1,5 conduit, Double pole applications MICRO SWITCH™ Medium-Duty Limit Switches BZE6-2RN28-S Differential Travel mm [in] max. BZ, SPDT Over Travel mm [in] min. BZE6-2RN28 Pretravel mm [in] max. A, 15 A A, 15 A A, 15 A H, 1A B, 10 A Operate Point mm [in] Electrical Rating [page 6] BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT DT, DPDT Operate Force N [oz] Switch type, Circuitry Table 6, continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Comments 2,78 to 5,57 [10 to 20] 2,78 to 5,57 [10 to 20] 2,78 to 5,57 [10 to 20] 2,78 to 5,57 [10 to 20] 2,78 to 8,35 [10 to 30] 71,42 Ref [2.812] 71,42 Ref [2.812] 71,42 Ref [2.812] 71,42 Ref [2.812] 69,44 Ref [2.734] 4,83 [0.188] 4,83 [0.188] 4,83 [0.188] 4,83 [0.188] 6,76 [0.266] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 0,15 [0.006] 0,15 [0.006] 0,15 [0.006] 0,15 [0.006] 4,19 [0.165] 0.5-14 NPSM conduit thread Low temperature -40 °C [-40 °F] Gold-plated contacts Double pole applications A, 2,22 to 5,56 15 A [8 to 20] - 5,94 [0.234] 5,56 [0.219] 0,15 [0.006] BZ, SPDT A, 2,22 to 5,56 15 A [8 to 20] - 5,94 [0.234] 5,56 [0.219] 0,15 [0.006] 0.5-14 NPSM conduit thread DTE6-2RN28 DT, DPDT B, 10 A - 7,92 [0.312] 5,56 [0.219] 4,19 [0.165] Double pole applications BZE6-2RN62 BZ, SPDT A, 0,83 to 1,95 15 A [3 to 7] - 18,24 [0.718] 21,29 [838] 5,82 [0.229] BZE6-2RN18 BZ, SPDT A, 15 A 1,95 N max. [7.0 oz max.] - 15° 20° Ref - BZE6-2RN1872 BZ, SPDT H, 1A 1,95 N max. [7.0 oz max.] - 15° 20° Ref - BZE6-2RN4 BZ, SPDT A, 2,78 to 5,57 80,0 Ref [3.15] 15 A [10 to 20] 4,83 [0.188] 5,56 [0.219] 0,15 [0.006] Catalog Listing BZE6-2RN2 BZE6-2RN2-S BZE6-2RN234 BZE6-2RN272 Roller Lever One-way Roller Lever DTE6-2RN2 5,56 to10 [20 to 36] Low-force Rod Lever Gold-plated contacts Coil-spring Wobble Manual Palm Button sensing.honeywell.com 9 E6/V6 Series Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. Operate Point mm [in] Operate Force N [oz] Electrical Rating [page 6] Catalog Listing Switch type, Circuitry Table 6. continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. 1,98 [0.078] 5,56 [0.219] NA Reset position: 53,19 [2.094] max. 56,70 ± 1,14 [2.232 ± 0.045] 1,98 [0.078] 4,75 [0.187] NA Reset position: 53,19 [2.094] max. A, 4,45 N max. 15 A [16 oz max.] 71,42 Ref [2.812 in.] 4,83 [0.188] 5,56 [0.219] NA Reset position: 50,40 ± 1,14 [1.984 ± 0.045] A, 1,95 N max. 15 A [7.0 oz max.] - 15° 20° Ref NA Reset position: 50,40 ± 1,14 [1.984 ± 0.045] BZE6-RNX1 BZ, SPDT A, 1,67 to 5,56 43,64 ± 0,76 15 A [6 to 20] [1.718 ±0.030] BZE6-RN80X2 BZ, SPDT A, 15 A BZE6-RN2X1 BZ, SPDT BZE6-RN18X1 BZ, SPDT Comments Pin Plunger w Manual Reset 5,85 to 15,57 [21 to 56] Inline roller plunger w/ manual reset Roller Lever w/ Manual Reset Coil Spring Wobble w/ Manual Reset 10 sensing.honeywell.com MICRO SWITCH™ Medium-Duty Limit Switches DIMENSIONS Figure 2. Top pin plunger, side mount with boot seal ref. 2,0 mm [ref. 0.08 in] Figure 3. Top roller plunger, side mount with boot seal Ø 8,44 mm [Ø 0.33 in] 23,4 mm [0.92 in] 1/2-14 NPT Threads 56,64 mm [2.23 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 77,2 mm [3.04 in] 21,1 mm [0.83 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 19.0 mm [0.75 in] 43,7 mm OP [1.72 in OP] Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 21,1 mm [0.83 in] Figure 4. Cross roller plunger, side mount with boot seal Figure 5. Roller lever, adjustable, side mount with boot seal Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 56,64 mm [2.23 in] 39,6 mm [1.57 in] 18,3 mm [0.72 in] 19.0 mm [0.75 in] 1/2-14 NPT Threads 25,4 mm [1.00 in] 69,6 mm [2.74 in] 23,1 mm [0.91 in] 53,1 mm [2.09 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 77,2 mm [3.04 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] Figure 6. One-way roller lever, side mount with boot seal ] 6 in 1.5 3 18,3 mm [0.72 in] 152,4 mm [6.0 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 18,3 mm [0.72 in] 32,26 mm [1.27 in] 53,1 mm [2.09 in] 53,1 mm [2.09 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] m[ m 9,6 Figure 7. Rod lever, side mount with boot seal 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] sensing.honeywell.com 11 E6/V6 Series Figure 8. Manual palm button, side mount with boot seal m 8m 4 [1.4 Ø 7,11 mm [Ø 0.28 in] 5 36, Figure 9. Coil wobble, side mount with boot seal in] 38,1 mm [1.50 in] 18,3 mm [0.72 in] 108,97 mm [4.29 in] 31,75 mm [1.25 in] 149,35 mm [5.88 in] 53,1 mm [2.09 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 19.0 mm [0.75 in] 1/2-14 NPT Threads 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] Figure 10. Top pin plunger, reset, side mount with boot seal Figure 11. Top roller plunger, reset, side mount with boot seal Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller Ø 8,44 mm [Ø 0.33 in] 56,64 mm [2.23 in] 1/2-14 NPT Threads 22,6 mm [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 19.0 mm 53,1 mm [2.09 in] [0.75 in] 1/2-14 NPT Threads 25,4 mm 19.0 mm [1.00 in] [0.75 in] 53,1 mm [2.09 in] 43,69 mm [1.72 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 77,2 mm [3.04 in] Figure 12. Roller lever plunger, reset, side mount with boot seal Figure 13. Coil wobble plunger, reset, side mount with boot seal 39,6 mm [1.57 in] 18,3 mm [0.72 in] Ø 7,11 mm [Ø 0.28 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 108,97 mm [4.29 in] 23,1 mm [0.91 in] 149,35 mm [5.88 in] 53,1 mm [2.09 in] 1/2-14 NPT Threads 69,6 mm [2.74 in] 77,2 mm [3.04 in] sensing.honeywell.com 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 12 53,1 mm [2.09 in] 25,4 mm [1.00 in] 53,1 mm [2.09 in] 19.0 mm [0.75 in] 19.0 mm [0.75 in] 1/2-14 NPT Threads 22,6 mm [0.89 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] MICRO SWITCH™ Medium-Duty Limit Switches BME6-2RQ DTE6-2RQ BZE6-2RQ8 BZE6-2RQ8-S Inline Roller Plunger BZE6-2RQ8722 BZE6-2RQ81 BZE6-2RQ81-S BME6-2RQ81 Cross Roller Plunger DTE6-2RQ81 BZE6-2RQ2 BZE6-2RQ2-S Roller Lever DTE6-2RQ2 BZE6-2RQ28 DT, DPDT B, 10 A BZ, SPDT BZ, SPDT DT, DPDT A, 15 A A, 15 A B, 10 A BZ, SPDT A, 2,22 to 5,00 15 A [8 to 18] BZ, SPDT BZ, SPDT DT, DPDT A, 0,56 to 1,39 15 A [2 to 5] A, 0,56 to 1,39 15 A [2 to 5] B, 1,39 to 3,34 10 A [5 to 12] Differential Travel mm [in] max. Pin Plunger Over Travel mm [in] min. BZE6-2RQ72 Pretravel mm [in] max. BZE6-2RQ7 A, 15 A A, 15 A A, 15 A H, 1A G, 22 A B, 10 A A, 15 A A, 15 A H, 1A A, 15 A A, 15 A G, 22 A Operate Point mm [in] BZE6-2RQ-S BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT BM, SPDT DT, DPDT BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT BZ, SPDT BM, SPDT Operate Force N [oz] BZE6-2RQ Electrical Rating [page 6] Catalog Listing Switch type, Circuitry Table 7. Order Guide • E6 Series Switches, Side Mount without Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 5,56 to 11,12 [20 to 40] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 2,50 to 3,61 [9 to 13] 6,67 to 13,34 [24 to 48] 2,78 to 5,00 [10 to 18] 2,78 to 5,00 [10 to 18] 2,78 to 5,57 [10 to 20] 38,1 ±0,76 [1.5 ±0.030] 38,1 ±0,76 [1.5 ±0.030] 38,1 ±0,76 [1.5 ±0.030] 38,1 ±0,76 [1.5 ±0.030] 38,1 ±0,76 [1.5 ±0.030] 47,88 ±0,76 [1.885 ±0.030] 49,61 ±1,14 [1.953 ±0.045] 49,61 ±1,14 [1.953 ±0.045] 49,61 ±1,14 [1.953 ±0.045] 49,61 ±1,14 [1.953 ±0.045] 49,61 ±1,14 [1.953 ±0.045] 49,61 ±1,14 [1.953 ±0.045] 0,38 [0.015] 0,38 [0.015] 0,38 [0.015] 0,38 [0.015] 0,38 [0.015] 3,81 [0.150] 0,38 [0.015] 0,38 [0.015] 0,38 [0.015] 0,38 [0.015] 0,38 [0.015] 0,38 [0.015] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 2,24 [0.088] 3,56 [0.140] 3,56 [0.140] 3,56 [0.140] 3,56 [0.140] 3,56 [0.140] 3,56 [0.140] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 1,52 [0.060] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 49,61 ±1,14 [1.953 ±0.045] 3,58 [0.141] 3,18 [0.125] 1,52 [0.060] Double pole applications 61,11 Ref [2.406] 61,11 Ref [2.406] 69,44 Ref [2.734] 4,83 [0.188] 4,83 [0.188] 6,76 [0.266] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 0,15 [0.006] 0,15 [0.006] 4,19 [0.165] 0.5-14 NPSM conduit thread Double pole applications - 5,94 [0.234] 5,56 [0.219] 0,15 [0.006] 18,24 [0.718] 18,24 [0.718] 27,94 [1,100] 21,29 [0.838] 21,29 [0.838] 21,29 [0.838] 5,82 [0.229] 5,82 [0.229] 14,22 [0.560] Comments 0.5-14 NPSM conduit thread #8 mounting screws Gold-plated contacts Higher current ac applications Double pole applications 0.5-14 NPSM conduit thread Gold-plated contacts 0.5-14 NPSM conduit thread Higher current ac applications One-way Roller Lever BZE6-2RQ62 BZE6-2RQ62-S Low-force Rod Lever DTE6-2RQ62 - 0.5-14 NPSM conduit thread Double pole applications sensing.honeywell.com 13 E6/V6 Series Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. BZE6-2RQ4 BZ, SPDT A, 2,78 to 5,00 15 A [10 to 18] - - 5,56 [0.219] 0,15 [0.006] BZE6-RQX2 BZ, SPDT A, 1,67 to 2,64 15 A [6 to 9.5] 38,1 ±0,76 [1.5 ±0.030] 0,30 [0.012] 4,75 [0.187] NA Reset position: 46,84 [1.844] max. BZE6-RQ8X2 BZ, SPDT A, 1,47 to 2,64 51,18 ± 1,14 15 A [6 to 9.5] [2.015 ±0.045] 0,30 [0.012] 3,56 [0.140] NA Reset position: 46,84 [1.844] max. BZE6-RQ81X2 BZ, SPDT A, 1,47 to 2,64 51,18 ± 1,14 15 A [6 to 9.5] [2.015 ±0.045] 0,30 [0.012] 3,56 [0.140] NA Reset position: 46,84 [1.844] max. BZE6-RQ2X2 BZ, SPDT A, 15 A 4,83 [0.188] 5,56 [0.219] NA Reset position: 46,84 [1.844] max. Catalog Listing Switch type, Circuitry Operate Point mm [in] Operate Force N [oz] Electrical Rating [page 6] Table 7, continued. Order Guide • E6 Series Switches, Side Mount without Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Comments Manual Palm Button Pin Plunger w Manual Reset Inline Roller Plunger w/ Manual Reset Cross Roller Plunger w/ Manual Reset Roller Lever w/ Manual Reset 14 sensing.honeywell.com 3,34 approx. [12 oz ] 61,11 Ref [2.406] MICRO SWITCH™ Medium-Duty Limit Switches DIMENSIONS Figure 14. Top pin plunger, side mount Figure 15. Top roller plunger, side mount Ø 8,44 mm [Ø 0.33 in] 23,4 mm [0.92 in] 1/2-14 NPT Threads 49,61 mm [1.95 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 19.0 mm [0.75 in] 38,1 mm [1.50 in] Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] Figure 17. Roller lever, adjustable, side mount Figure 16. Cross roller plunger, side mount Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 1/2-14 NPT Threads 39,6 mm [1.57 in] 18,3 mm [0.72 in] 19.0 mm [0.75 in] 49,61 mm [1.95 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 1/2-14 NPT Threads 42,9 mm [1.69 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 23,1 mm [0.91 in] 77,2 mm [3.04 in] 19.0 mm [0.75 in] 25,4 mm [1.00 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 25,4 mm [1.00 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] Figure 18. One-way roller lever, side mount 6 1.5 m[ 152,4 mm [6.0 in] 18,3 mm [0.72 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 18,3 mm [0.72 in] 32,26 mm [1.27 in] 42,93 mm [1.69 in] 19.0 mm [0.75 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 1/2-14 NPT Threads 42,93 mm [1.69 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 6m 39, Figure 19. Rod lever, side mount in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] sensing.honeywell.com 15 E6/V6 Series Figure 20. Manual palm button, side mount 46,74 mm [1.84 in] 31,75 mm [1.25 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 46,74 mm [1.84 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 23,1 mm [0.91 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 25,4 mm [1.00 in] 46,74 mm [1.84 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] sensing.honeywell.com 25,4 mm [1.00 in] 77,2 mm [3.04 in] Figure 24. Roller lever, reset, side mount 42,9 mm [1.69 in] 22,6 mm [0.89 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 18,3 mm [0.72 in] Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 1/2-14 NPT Threads 49,61 mm [1.95 in] [0.75 in] 25,4 mm [1.00 in] 19.0 mm 51,31 mm [2.02 in] 46,74 mm [1.84 in] Figure 23. Cross roller plunger, reset, side mount 1/2-14 NPT Threads 25,4 mm [1.00 in] 16 69,6 mm [2.74 in] 77,2 mm [3.04 in] Figure 22. Roller plunger, reset, side mount 39,6 mm [1.57 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 22,6 mm [0.89 in] 25,4 mm mm [1.00 in] 19.0 [0.75 in] 42,93 mm [1.69 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 18,3 mm [0.72 in] 25,4 mm [1.00 in] 38,1 mm [1.50 in] 36 25,4 mm [1.00 in] Ø 8,44 mm [Ø 0.33 in] 38,1 mm [1.50 in] 4 1.4 m[ m ,58 Figure 21. Top pin plunger, reset, side mount in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] MICRO SWITCH™ Medium-Duty Limit Switches Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. Table 8. Order Guide • V6 Series Switches, Flange Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Comments BZ, SPDT BZ, SPDT BZ, SPDT DT, DPDT A, 15 A A, 15 A A, 15 A B, 10 A 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 2,50 to 6,67 [9 to 24] 7,23 to 16,4 [26 to 59] 69,09 ±1,52 [2.720 ±0.060] 69,09 ±1,52 [2.720 ±0.060] 69,09 ±1,52 [2.720 ±0.060] 71,42 ±0,76 [2.812 ±0.030] 1,98 [0.078] 1,98 [0.078] 1,98 [0.078] 2,79 [0.110] 5,56 [0.219] 5,56 [0.219] 5,56 [0.219] 3,18 [0.125] 0,05 [0.002] 0,05 [0.002] 0,05 [0.002] 1,52 [0.060] 0.5-14 NPSM conduit thread Low temperature -40 °C [-40 °F] Double pole applications BZV6-2RN80 BZ, SPDT A, 2,50 to 6,67 82,09 ±1,14 15 A [9 to24] [3.232 ±0.045] 1,98 [0.078] 5,56 [0.219] 0,05 [0.002] BZV6-2RN81 BZ, SPDT A, 2,50 to 6,67 82,09 ±1,14 15 A [9 to24] [3.232 ±0.045] 1,98 [0.078] 5,56 [0.219] 0,05 [0.002] BZV6-2RN2 BZ, SPDT A, 2,78 to 5,57 15 A [10 to 20] 96,82 Ref [3.812] 4,83 [0.188] 5,56 [0.219] 0,15 [0.006] DTV6-2RN2 DT, DPDT B, 2,78 to 8,35 10 A [10 to 30] 94,84 Ref [3.734] 6,76 [0.266] 5,56 [0.219] 4,19 [0.165] BZV6-2RN28 BZ, SPDT A, 2,22 to 5,56 15 A [8 to 20] - 5,94 [0.234] 5,56 [0.219] 0,15 [0.006] BZV6-2RN62 BZ, SPDT A, 0,83 to 1,95 15 A [3 to 7] - 18,24 [0.718] 21,29 [0.838] 5,82 [0.229] Catalog Listing BZV6-2RN BZV6-2RN-S BZV6-2RN34 Pin plunger DTV6-2RN Inline Roller Plunger Cross Roller Plunger Double pole applications Roller Lever One-way Roller Lever Low-force Rod Lever sensing.honeywell.com 17 E6/V6 Series BZ, SPDT A, 2,78 to 5,57 15 A [10 to 20] BZV6-RNX1 BZ, SPDT A, 1,67 to 5,56 69,09 ±1,52 15 A [6 to 20] [2.720 ±0.060] Differential Travel mm [in] max. BZV6-2RN4 Over Travel mm [in] min. A, 15 A Pretravel mm [in] max. BZ, SPDT Operate Point mm [in] Electrical Rating [page 6] BZV6-2RN18 Catalog Listing Operate Force N [oz] Switch type, Circuitry Table 8, continued. Order Guide • V6 Series Switches, Flange Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. 1,95 N. max. [7.0 oz max.] - 15° 20° Ref - 105,56 Ref. [4.156] 4,83 [0.188] 5,56 [0.219] 0,15 [0.006] 1,98 [0.078] 4,78 [0.188] NA Comments Coil-spring Wobble Manual Palm Button Pin Plunger w Manual Reset 18 sensing.honeywell.com Reset position: 26,97 [1.062] max. MICRO SWITCH™ Medium-Duty Limit Switches DIMENSIONS Figure 25. Top pin plunger, flange mount with boot seal 2,0 mm [0.08 in] Figure 26. Top roller plunger, flange mount with boot seal Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller Ø 8,44 mm [Ø 0.33 in] 82,04 mm [3.23 in] 1/2-14 NPT Threads 69,1 mm [2.72 in] 2X Ø 4,37 mm [Ø 0.172 in] 44,4 mm [1.75 in] 1/2-14 NPT Threads 2X Ø 4,37 mm [Ø 0.172 in] 44,4 mm [1.75 in] 22,6 mm [0.89 in] 22,6 mm [0.89 in] 10,7 mm [0.42 in] 3,3 mm [0.13 in] 25,4 mm [1.00 in] 41,4 mm [1.63 in] 69,6 mm [2.74 in] 3,3 mm [0.13 in] 25,4 mm [1.00 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] 54,1 mm [2.13 in] Figure 27. Cross roller plunger, flange mount with boot seal Figure 28. Roller lever adjustable, flange mount with boot seal Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 56,64 mm [2.23 in] 39,6 mm [1.57 in] 18,3 mm [0.72 in] 1/2-14 NPT Threads 25,4 mm [1.00 in] 53,1 mm [2.09 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 10,7 mm [0.42 in] 3,3 mm [0.13 in] 23,1 mm [0.91 in] 69,6 mm [2.74 in] 41,4 mm [1.63 in] 77,2 mm [3.04 in] 54,1 mm [2.13 in] 1/2-14 NPT Threads 2X Ø 4,37 mm [Ø 0.172 in] 19.0 mm [0.75 in] 19.0 mm [0.75 in] 2X Ø 4,37 mm [Ø 0.172 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 25,4 mm [1.00 in] 3,3 mm [0.13 in] 22,6 mm [0.89 in] 25,4 mm [1.00 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] Figure 29. One-way roller lever, flange mount with boot seal 18,3 mm [0.72 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller 18,3 mm [0.72 in] 32,26 mm [1.27 in] 53,1 mm [2.09 in] 53,1 mm [2.09 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 2X Ø 4,37 mm [Ø 0.172 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 10,7 mm [0.42 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 19.0 mm [0.75 in] 1/2-14 NPT Threads 2X Ø 4,37 mm [Ø 0.172 in] 25,4 mm [1.00 in] 3,3 mm [0.13 in] 152,4 mm [6.0 in] ] 6 in 1.5 m[ 6m 39, Figure 30. Rod lever, flange mount with boot seal 25,4 mm [1.00 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] 3,3 mm [0.13 in] 22,6 mm [0.89 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] sensing.honeywell.com 19 E6/V6 Series Figure 31. Manual palm button, flange mount with boot seal 58 36, mm Figure 32. Coil wobble, flange mount with boot seal ] 4 in Ø 7,11 mm [Ø 0.28 in] [1.4 38,1 mm [1.50 in] 18,3 mm [0.72 in] 108,97 mm [4.29 in] 31,75 mm [1.25 in] 149,35 mm [5.88 in] 53,1 mm [2.09 in] 1/2-14 NPT Threads 1/2-14 NPT Threads 25,4 mm [1.00 in] 25,4 mm [1.00 in] 22,6 mm [0.89 in] 3,3 mm [0.13 in] 25,4 mm [1.00 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] Figure 33. Top pin plunger, reset, flange mount with boot seal 10,7 mm [0.42 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 2X Ø 4,37 mm [Ø 0.172 in] 25,4 mm [1.00 in] 53,1 mm [2.09 in] 43,69 mm [1.72 in] Ø 8,44 mm [Ø 0.33 in] 22,6 mm [0.89 in] 3,3 mm [0.13 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 20 sensing.honeywell.com 2X Ø 4,37 mm [Ø 0.172 in] 19.0 mm [0.75 in] 19.0 mm [0.75 in] 2X Ø 4,37 mm [Ø 0.172 in] 25,4 mm [1.00 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] 3,3 mm [0.13 in] 22,6 mm [0.89 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] MICRO SWITCH™ Medium-Duty Limit Switches Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. BZV6-2RQ BZ, SPDT A, 2,50 to 3,61 15 A [9 to 13] 63,50 ±1,14 [2.50 ±0.045] 0,38 [0.015] 5,56 [0.219] 0,05 [0.002] BZV6-2RQ8 BZ, SPDT A, 2,50 to 3,61 75,01 ±1,52 15 A [9 to 13] [2.953 ±0.060] 0,38 [0.015] 3,56 [0.140] 0,05 [0.002] BZV6-2RQ81 BZ, SPDT A, 2,50 to 3,61 75,01 ±1,52 15 A [9 to 13] [2.953 ±0.060] 0,38 [0.015] 3,56 [0.140] 0,05 [0.002] BZV6-2RQ2 BZ, SPDT A, 2,78 to 5,00 15 A [10 to 18] 86,51 Ref [3.406] 4,83 [0.188] 5,56 [0.219] 0,15 [0.006] BZV6-2RQ62 BZ, SPDT A, 0,56 to 1,39 15 A [2 to 5] - 18,24 [0.718] 21,29 [0.838] 5,82 [0.229] Catalog Listing Switch type, Circuitry Operate Point mm [in] Operate Force N [oz] Electrical Rating [page 6] Table 9. Order Guide • V6 Series Switches, Flange Mount without Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Comments Pin plunger Inline Roller Plunger Cross Roller Plunger Roller Lever Low-force Rod Lever sensing.honeywell.com 21 E6/V6 Series DIMENSIONS Figure 34. Top pin plunger, flange mount Figure 35. Top roller plunger, flange mount Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller Ø 8,44 mm [Ø 0.33 in] 74,93 mm [2.95 in] 1/2-14 NPT Threads 63,5 mm [2.50 in] 2X Ø 4,37 mm [Ø 0.172 in] 44,4 mm [1.75 in] 1/2-14 NPT Threads 2X Ø 4,37 mm [Ø 0.172 in] 44,4 mm [1.75 in] 22,6 mm [0.89 in] 22,6 mm [0.89 in] 3,3 mm [0.13 in] 25,4 mm [1.00 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 41,4 mm [1.63 in] 3,3 mm [0.13 in] 25,4 mm [1.00 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] 54,1 mm [2.13 in] Figure 36. Cross roller plunger, flange mount Figure 37. Roller lever adjustable, flange mount Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 74,9 mm [2.95 in] 39,6 mm [1.57 in] 18,3 mm [0.72 in] 1/2-14 NPT Threads 2X Ø 4,37 mm [Ø 0.172 in] 22,6 mm [0.89 in] 3,3 mm [0.13 in] 25,4 mm [1.00 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 152,4 mm [6.0 in] 1/2-14 NPT Threads 19.0 mm [0.75 in] 2X Ø 4,37 mm [Ø 0.172 in] 25,4 mm [1.00 in] 3,3 mm [0.13 in] 22,6 mm [0.89 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] 22 sensing.honeywell.com 22,6 mm [0.89 in] 10,7 mm [0.42 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 25,4 mm [1.00 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] 18,3 mm [0.72 in] 42,93 mm [1.69 in] 2X Ø 4,37 mm [Ø 0.172 in] 25,4 mm [1.00 in] 3,3 mm [0.13 in] Figure 38. Rod lever, flange mount 1/2-14 NPT Threads 42,9 mm [1.69 in] 41,4 mm [1.63 in] 54,1 mm [2.13 in] 23,1 mm [0.91 in] 19.0 mm [0.75 in] 44,4 mm [1.75 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W roller MICRO SWITCH™ Medium-Duty Limit Switches E6/V6 REPLACEMENT PARTS The metal bottom cover includes the insulator seal and two cover screws The plunger seal boot includes the plunger seal and retaining hardware The hardware packet includes mounting hardware and seal boot as noted in the tables Table 10. Actuator with Boot Seal Replacement Parts Cat. Listing Bottom Cover Plunger Seal Boot1 Hardware Packet Internal Basic Switch Actuator BZE6-2RN 3PA13-E6 10PA2 1PA2* BZ-2RQ77** Integral to internal basic switch BZV6-2RN 3PA14-V6 10PA2 1PA2* BZ-2RQ77** Integral to internal basic switch BZE6-2RN7 3PA13-E6 10PA2 1PA46*2 BZ-2RN730** Integral to internal basic switch BZE6-2RN72 3PA13-E6 10PA2 1PA2* BZ-2RQ7722** Integral to internal basic switch BZE6-2RN80 3PA13-E6 10PA2 1PA47 BZ-2RN784 Integral to internal basic switch BZE6-2RN2 3PA13-E6 10PA2 1PA13* BZ-2RN702** 6PA2* BZV6-2RN2 3PA14-V6 10PA2 1PA13* BZ-2RN702** 6PA2* BZE6-2RN18 3PA13-E6 10PA2 - BZ-2R-A2 6PA1953 BZV6-2RN18 3PA14-V6 10PA2 - BZ-2R-A2 6PA1953 DTE6-2RN 3PA13-E6 10PA2 1PA2 DT-2R3-A7 8PA14 DTV6-2RN 3PA14-V6 10PA2 1PA2 DT-2R3-A7 8PA14 DTE6-2RN2 3PA13-E6 10PA2 - DT-2R3-A7 6PA2* DTV6-2RN2 3PA14-V6 10PA2 - DT-2R3-A7 6PA2* *Includes plunger seal boot **Includes hardware packet 1. To order replacement low temperature plunger boot seal (switch code 34), specify 10PA1 2. 1PA46 hardware packet cannot be ordered separately. When BZ-2RN730 internal basic switch is ordered, the 1PA46 hardware packet is included with internal basic switch. 3. To order replacement wobble actuator including internal threaded bushing, specify 6PA188-F Table 11. Actuator without Boot Seal Replacement Parts Cat. Listing Bottom Cover Hardware Packet Internal Basic Switch Actuator BZE6-2RQ 3PA13-E6 1PA1 BZ-2RQ66 Integral to internal basic switch BZV6-2RQ 3PA14-V6 1PA1 BZ-2RQ66 Integral to internal basic switch BZE6-2RQ8 3PA13-E6 1PA19 BZ-2RQ784** Integral to internal basic switch BZV6-2RQ8 3PA14-V6 1PA19 BZ-2RQ784** Integral to internal basic switch BZE6-2RQ81 3PA13-E6 1PA19 BZ-2RQ785** Integral to internal basic switch BZV6-2RQ81 3PA14-V6 1PA19 BZ-2RQ785** Integral to internal basic switch BZE6-2RQ2 3PA13-E6 1PA3 BZ-2RQ68** 6PA1 BZV6-2RQ2 3PA14-V6 1PA3 BZ-2RQ68** 6PA1 **Includes hardware packet sensing.honeywell.com 23 E6/V6 Series This Honeywell datasheet supports the following MICRO SWITCH™ E6/V6 Series Limit Switch Listings BZE6-2RN4 BZE6-2RN7 BZE6-2RN80 BZE6-2RQ2 BZE6-RN80X2 BZE6-2AQ BZE6-2AQ8T BZE6-2GN BZE6-2RN BZE6-2RN18 BZE6-2RN1809-5 BZE6-2RN1810 BZE6-2RN1812 BZE6-2RN183 BZE6-2RN185 BZE6-2RN185-WP BZE6-2RN187 BZE6-2RN1872 BZE6-2RN18721 BZE6-2RN18-C3 BZE6-2RN19 BZE6-2RN191-S BZE6-2RN193 BZE6-2RN196-F5 BZE6-2RN2 BZE6-2RN221 BZE6-2RN224 BZE6-2RN234 BZE6-2RN272 BZE6-2RN28 BZE6-2RN281 BZE6-2RN28-S BZE6-2RN2-F3 BZE6-2RN2-F6 BZE6-2RN2-S BZE6-2RN2-TW BZE6-2RN34 BZE6-2RN37 BZE6-2RN39 BZE6-2RN5 BZE6-2RN51 BZE6-2RN62 BZE6-2RN72 24 sensing.honeywell.com BZE6-2RN72-S BZE6-2RN7-S BZE6-2RN8 BZE6-2RN8034 BZE6-2RN81 BZE6-2RN-C BZE6-2RN-F1 BZE6-2RN-F3 BZE6-2RN-F6 BZE6-2RN-FR BZE6-2RN-M BZE6-2RN-R BZE6-2RN-S BZE6-2RQ BZE6-2RQ125 BZE6-2RQ136 BZE6-2RQ165 BZE6-2RQ168 BZE6-2RQ219 BZE6-2RQ241 BZE6-2RQ28 BZE6-2RQ2-S BZE6-2RQ4 BZE6-2RQ5 BZE6-2RQ62 BZE6-2RQ62-S BZE6-2RQ7 BZE6-2RQ72 BZE6-2RQ8 BZE6-2RQ81 BZE6-2RQ814 BZE6-2RQ81-S BZE6-2RQ841-BP BZE6-2RQ8722 BZE6-2RQ8-S BZE6-2RQ9 BZE6-2RQ9-S BZE6-2RQ-S BZE6-3RN BZE6-3RN18150-C BZE6-3RN2153 BZE6-3YN2 BZE6-3YNP BZE6-3YNT BZE6-3YQ9 BZE6-3YQT BZE6-7RN BZE6-7RN18 BZE6-7RN1812 BZE6-7RN51 BZE6-7RN8051 BZE6-7RNT BZE6-7RQ8 BZE6-7RQ9 BZE6-7RQ9T BZE6-RN BZE6-RN18X1 BZE6-RN18X2 BZE6-RN18X3 BZE6-RN2X1 BZE6-RNX1 BZE6-RNX12 BZE6-RNX17 BZE6-RQ BZE6-RQ2 BZE6-RQ2X2 BZE6-RQ71 BZE6-RQ81X2 BZE6-RQ8X2 BZE6-RQ8X4 BZE6-RQ9 BZE6-RQX2 BZV6-2RN BZV6-2RN18 BZV6-2RN2 BZV6-2RN28 BZV6-2RN34 BZV6-2RN4 BZV6-2RN62 BZV6-2RN80 BZV6-2RN81 BZV6-2RN-C BZV6-2RN-S BZV6-2RQ BZV6-2RQ2 BZV6-2RQ39 BZV6-2RQ62 BZV6-2RQ8 BZV6-2RQ81 BZV6-2RQ9 BZV6-7RN BZV6-7RN2T BZV6-RNX1 10PA1 10PA2 19PA22-E6 3PA13-E6 3PA14-V6 6PA140-E6 6PA147-E6 6PA148-E6 6PA187-E6 BME6-2RN BME6-2RN2 BME6-2RN373 BME6-2RQ BME6-2RQ171 BME6-2RQ173 BME6-2RQ273 BME6-2RQ81 DTE6-2RN DTE6-2RN2 DTE6-2RN28 DTE6-2RN281 DTE6-2RN4 DTE6-2RN80 DTE6-2RN8034-M DTE6-2RQ DTE6-2RQ2 DTE6-2RQ62 DTE6-2RQ81 DTE6-2RQ9 DTV6-2RN DTV6-2RN2 DTV6-2RN4 HSE6-3RNT2 MICRO SWITCH™ Medium-Duty Limit Switches ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com: • Product installation instructions • Product range guide • Product nomenclature tree • Product application-specific information WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. – Limit and enclosed switch reference standards WARNING – Application note: Machine tool application guide – Application note: Industrial machinery switch guide MISUSE OF DOCUMENTATION • • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. sensing.honeywell.com 25 Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell’s sensing and control products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 002383-2-EN IL50 GLO  December 2014 Copyright © 2014 Honeywell International Inc. All rights reserved.
DTE6-2RN2 价格&库存

很抱歉,暂时无法提供与“DTE6-2RN2”相匹配的价格&库存,您可以联系我们找货

免费人工找货