MICRO SWITCH™
Medium-Duty Limit Switches
E6/V6 Series
Datasheet
MICRO SWITCH™ E6/V6 Series
Medium-Duty Limit Switches
Honeywell MICRO SWITCH™ E6/V6 Series medium-duty limit switches are designed for a wide variety of indoor and
outdoor applications. Typical applications include equipment for commercial, industrial, transportation, and agriculture
industries. The electrostatic applied epoxy coating to the zinc housings enhance the durability of the product in most
environments. The E6/V6 family of switches incorporates the Honeywell MICRO SWITCH™ BZ switch element which
has the reliable snap-spring mechanism with more than 60 years of proven service.
The sealed (actuators with boots) E6/V6 Series switches are preferred for applications where there could be
exposure to liquid and/or particulate environments. The general purpose (actuators without boot seals) E6/V6 Series
switches are ideal for applications where there will not be exposure to liquid or dust environments.
The compact size of these limit switches permits installation where there is limited space available on equipment.
Most SPDT (Single Pole Double Throw) E6/V6 catalog listings are certified to UL, CSA, and CE while the DPDT
(Double Pole Double Throw) E6/V6 catalog listings are certified to UL and CSA.
What makes our switches better?
Designed with MICRO SWITCH™ BZ, BM, or DT basic switches
to deliver precise switching of electrical and mechanical operating
characteristics
High capacity (22 A) available with BME6 Series switch
Small footprint with easy access to wiring terminals
Available in a configuration suited to the application with variety of
actuators, circuitries, connectivities, and mounting options
HIGH PERFORMANCE • DURABILITY
CUSTOMIZATION • EASY TO INSTALL
2
sensing.honeywell.com
Features
and Benefits
DESIGNED FOR DEMANDING ENVIRONMENTS AND
APPLICATIONS
MICRO SWITCH™ E6/V6 Series switches feature an electrostatic epoxy coated
zinc housing for durability in most indoor and outdoor environments, and a wide
variety of actuators to solve most application requirements.
Side and flange mounting options
RELIABLY HANDLES ELECTRICAL LOADS
The E6/V6 Series are available with SPDT contacts with momentary or maintained
action, or DPDT contacts with momentary action. These switches also offer goldplated switch contacts for logic-level circuits and silver alloy contacts for power
duty circuits. The internal ground screw is provided to meet electrical codes as
required.
DESIGN FLEXIBILITY
These limit switches are offered with multiple connectivity options: three different
conduit offerings, four-pin “mini” style connector, pre-wired 16-gage fourconductor cable, pigtail with three-pin Deutsch connector.
GLOBAL APPROVALS
E6/V6 Series switches are UL, CSA, and CE certified for most SPDT catalog
listings. The DPDT catalog listings are UL and CSA certified.
LOW TEMPERATURE OPTIONS
The E6/V6 Series’ standard temperature range is -32 °C to 71 °C [-25 °F to
160 °F] with an optional -40 °C [-40 °F] low temperature.
sensing.honeywell.com
3
Figure 1. MICRO SWITCH™ E6 Side Mount and V6 Flange Mount with Features and Options
Stainless steel roller
Wide choice of actuators and
operating characteristics
Diaphragm boot seal
for long life
Single or double pole switches
Multiple conduit options
for ease of
connectivity
Rugged zinc housing and cover are phosphate treated and
epoxy coated for environmental durability
Popular 25,4 mm [1 in] mounting pattern
Terminal screws of switch easily
accessed with cover removed
Captive cover screws (2)
Internal ground screw provided in cover
Cover with one-piece molded insulator seal
Figure 1A. E6 Side mount with boot sealed actuator (typical)
Wide choice of actuator styles and
operating characteristics
Hardened steel plunger for long life
Rugged zinc housing and cover phosphate
treated and electrostatic epoxy coated
for environmental durability
Single or double pole switches
Multiple conduit options
for ease
of connectivity
Terminal screws of switch easily
accessed with cover removed
Captive cover screws (2)
Internal ground screw provided in cover
Optional flange base mounting
Cover with one-piece molded insulator seal
Figure 1B. V6 Flange mount without boot sealed actuator (typical)
4
sensing.honeywell.com
Potential Applications
INDUSTRIAL
• Packaging equipment (balers, door interlocks)
• Air curtains (control of air movement)
• Conveyors (diverters, gates)
TRANSPORTATION
• Construction machinery and equipment (door and panel interlocks)
• Rail maintenance equipment (door and panel interlocks, position sensing)
• Agricultural equipment (grain handling)
Table 1. Specifications
Characteristic
Actuators
Housing material
Termination
Sealing
Switching options
Mechanical endurance
Electrical endurance
Operating temperature
Agency approvals
Parameter
top pin plunger (with and without boot seal)
top roller plunger, parallel with long axis of switch (with and without boot seal)
cross roller plunger, perpendicular with long axis of switch (with and without boot seal)
manually operated (with boot seal)
roller arm, adjustable (with and without boot seal)
one-way roller lever (with boot seal)
low-force rod lever (with and without boot seal)
wobble (with boot seal)
manual reset switches: top pin plunger, top roller plunger, adjustable roller arm, wobble
electrostatic epoxy coated zinc die-cast
see table 2 below
actuator with boot seal: NEMA 1, 3, 4, IP66
actuator without seal boot: NEMA 1, IP40
SPDT (snap-action contacts, 1NO/1NC)
SPDT-DB (double break snap-action contacts, 1NO/1NC)
DPDT (snap-action contacts, 2NO/2NC)
up to five million cycles for BZx6 and BMx6 switches; up to two million cycles for DTx6 switches
up to 50K cycles at full rated load
-32 °C to 71 °C [-25 °F to 160 °F] (standard)
-40 °C to 71 °C [-40 °F to 160 °F] (optional low temperature)
UL, CSA, CE
Table 2. Terminations
Catalog Listing Suffixes
none
Description
0.5 - 14 NPT conduit thread
S
0.5 - 14 NPSM conduit thread
M
M20 - 1,5 mm conduit thread
R
four-pin “mini” style connector
F1
305 mm [12 in] pigtail STOW-A, three conductor, 16-gage cable with three-pin Deutsch connector
F3
914 mm [36 in] 16-gage, four-conductor STO, PVC jacketed cable
sensing.honeywell.com
5
E6/V6 Series
Table 3. Electrical Ratings
Rating Code
UL, CSA Rating
CE Rating
A
15 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
B
10 A @ 125 Vac, 250 Vac
0.3 A @ 125 Vdc, 0.15 A @ 250 Vdc
–
C
15 A @125 Vac, 250 Vac or 480 Vac;
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
D
8 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
E
10 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac;
1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
F
15 A @125 Vac, 250 Vac or 480 Vac;
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;
1.0 A @ 125 Vdc, 0.5 A @ 250 Vdc
EN60947-5-1, IEC60947-5-1
AC15, B300
G
22 A @125 Vac, 250 Vac or 480 Vac;
1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac;
0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc
–
H
1A @ 125 Vac (Gold-plated contacts)
IEC 61058-1
1A, 250 Vac
Table 4. CE Electrical Rating, EN60947-5-1, IEC 60947-5-1
Designation &
Category
Vac
Amps Make
Amps Break
Continuous
Current (A)
VA Rating Make
VA Rating Break
AC15, B300
120
30
3.0
5
3600
360
AC15, B300
240
15
1.5
5
3600
360
Table 5. Switching
SPDT
C
6
sensing.honeywell.com
DPDT
NC
NO
SPDT-DB
C
NC
NO
C
NC
NO
NC
NO
NC
NO
MICRO SWITCH™ Medium-Duty Limit Switches
PRODUCT NOMENCLATURE
BZ
E6
Switch Type
Enclosure
Type
BZ Series
Basic Switch
SPDT, 15 A
DT Series
Basic Switch
DPDT, 10 A
BM Series
Basic Switch
SPDT, 22 A
E6
Side mount
V6
Flange mount
—
2
R
N
Internal Basic
Switch Construction
Contact
Plunger
Type
For use with “X” actuator,
maintained contact2
(blank)
2
Standard
7
Special2
R
Standard
(Single-break)
A
Double-break
(BZ basic switch only)
N
Q
Actuator
Modifications3
Additional
Modifications
0.5-14 NPT
conduit thread
Seal boot
Pin plunger
No seal boot
X
Maintained
contact with
reset plunger2
C3
2
Adjustable
roller lever
F1
Pre-leaded, 3 ft
cable, conduit
area epoxy sealed
12-inch pigtail
cable with 3-pin
Deutsch connect.
4
Manual, palm
button
F3
Epoxy sealed,
3 ft of cable
7
#8 mounting
screws
F5
Epoxy sealed,
5 ft of cable
8
80
Roller plunger
F6
Epoxy sealed,
6 ft of cable
18
Coil spring
wobble stick
FR
Epoxy sealed,
4-pin “mini style”
connector
28
One-way
roller lever
R
4-pin “mini style”
connector
34
Low temp.
S
1/4-14 NPSM
conduit threads
Rod
lever
M
M20 x 1,5 mm
conduit thread
NOTE:
1. Not all combinations of model codes are available.
Contact your Honeywell rep or distributor for assistance.
2. BZ Series only.
3. More than one actuator modification may be permissible.
For example, BZE6-2RN8034 is a roller plunger with low temperature seals.
(blank)
62
72
722
81
(blank)
Gold-contact
switch
Cross
roller plunger
sensing.honeywell.com
7
E6/V6 Series
Pretravel
mm [in] max.
Over Travel
mm [in] min.
Differential
Travel
mm [in] max.
Operate Point
mm [in]
Operate Force
N [oz]
A,
2,50 to 6,67 43,66 ±0,76
15 A
[9 to 24]
[1.719 ±0.030]
1,98
[0.078]
5,56
[0.219]
0,05
[0.002]
BZE6-2RN-F1
BZ,
SPDT
E,
2,50 to 6,67 43,66 ±0,76
10 A
[9 to 24]
[1.719 ±0.030]
1,98
[0.078]
5,56
[0.219]
0,05
[0.002]
BZE6-2RN-F3
BZ,
SPDT
E,
2,50 to 6,67 43,66 ±0,76
10 A
[9 to 24]
[1.719 ±0.030]
1,98
[0.078]
5,56
[0.219]
0,05
[0.002]
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT,
Double
break
BM,
SPDT
DT,
DPDT
BZ,
SPDT
BZ,
SPDT
DT,
DPDT
A,
15 A
D,
8A
A,
15 A
A,
15 A
A,
15 A
H,
1A
43,66 ±0,76
[1.719 ±0.030]
43,66 ±0,76
[1.719 ±0.030]
43,66 ±0,76
[1.719 ±0.030]
43,66 ±0,76
[1.719 ±0.030]
43,66 ±0,76
[1.719 ±0.030]
43,66 ±0,76
[1.719 ±0.030]
1,98
[0.078]
1,98
[0.078]
1,98
[0.078]
1,98
[0.078]
1,98
[0.078]
1,98
[0.078]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
F,
2,50 to 6,67 43,66 ±0,76
15 A
[9 to 24]
[1.719 ±0.030]
1,98
[0.078]
5,56
[0.219]
0,05
[0.002]
Recommended for
dc applications
G,
22 A
B,
10 A
A,
15 A
A,
15 A
B,
10 A
43,66 ±0,76
[1.719 ±0.030]
46,02 ±0,76
[1.812 ±0.030]
56,7 ±1,14
[2.232 ±0.045]
56,7 ±1,14
[2.232 ±0.045]
59,6 ±1,0
[2.345 ±0.040]
1,98
[0.078]
2,80
[0.110]
1,98
[0.078]
1,98
[0.078]
2,80
[0.110]
5,56
[0.219]
3,17
[0.125]
5,56
[0.219]
5,56
[0.219]
3,17
[0.125]
0,05
[0.002]
1,52
[0.060]
0,05
[0.002]
0,05
[0.002]
1,52
[0.060]
Higher current ac
applications
Double pole
applications
DTE62RN8034-M
DT,
DPDT
B,
5,56 to 13,3
59,6 ±1,0
10 A
[20 to 48] [2.345 ±0.040]
2,80
[0.110]
3,17
[0.125]
1,52
[0.060]
BZE6-2RN81
BZ,
SPDT
A,
2,50 to 6,67
56,7 ±1,14
15 A
[9 to24]
[2.232 ±0.045]
1,98
[0.078]
5,56
[0.219]
0,05
[0.002]
BZE6-2RN-M
BZE6-2RN-R
BZE6-2RN-S
BZE6-2RN7
Pin Plunger
BZE6-2RN34
BZE6-2RN72
BZE6-2AN
BME6-2RN
DTE6-2RN
BZE6-2RN80
BZE6-2RN8034
DTE6-2RN80
Inline Roller Plunger
Cross Roller
Plunger
sensing.honeywell.com
Switch type,
Circuitry
BZE6-2RN
BZ,
SPDT
Catalog Listing
8
Electrical
Rating [page 6]
Table 6. Order Guide • E6 Series Switches, Side Mount with Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
7,23 to 16,4
[26 to 59]
2,50 to 6,67
[9 to24]
2,50 to 6,67
[9 to24]
5,56 to 13,3
[20 to 48]
Comments
12 in. pigtail, 3
wire STO cable w/
Deutsch connector
Epoxy sealed with
36 in. 4 wire STO
cable
M20-1,5 conduit
thread
4-pin "mini" style
connector
0.5-14 NPSM
conduit thread
#8 mounting screws
Low temperature
-40 °C [-40 °F]
Gold-plated
contacts
Low temperature
-40 °C [-40 °F]
Double pole
applications
Low temp. -40 °C
[-40 °F], M20 -1,5
conduit, Double pole
applications
MICRO SWITCH™ Medium-Duty Limit Switches
BZE6-2RN28-S
Differential
Travel
mm [in] max.
BZ,
SPDT
Over Travel
mm [in] min.
BZE6-2RN28
Pretravel
mm [in] max.
A,
15 A
A,
15 A
A,
15 A
H,
1A
B,
10 A
Operate Point
mm [in]
Electrical
Rating [page 6]
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
DT,
DPDT
Operate Force
N [oz]
Switch type,
Circuitry
Table 6, continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
Comments
2,78 to 5,57
[10 to 20]
2,78 to 5,57
[10 to 20]
2,78 to 5,57
[10 to 20]
2,78 to 5,57
[10 to 20]
2,78 to 8,35
[10 to 30]
71,42 Ref
[2.812]
71,42 Ref
[2.812]
71,42 Ref
[2.812]
71,42 Ref
[2.812]
69,44 Ref
[2.734]
4,83
[0.188]
4,83
[0.188]
4,83
[0.188]
4,83
[0.188]
6,76
[0.266]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
0,15
[0.006]
0,15
[0.006]
0,15
[0.006]
0,15
[0.006]
4,19
[0.165]
0.5-14 NPSM
conduit thread
Low temperature
-40 °C [-40 °F]
Gold-plated
contacts
Double pole
applications
A,
2,22 to 5,56
15 A
[8 to 20]
-
5,94
[0.234]
5,56
[0.219]
0,15
[0.006]
BZ,
SPDT
A,
2,22 to 5,56
15 A
[8 to 20]
-
5,94
[0.234]
5,56
[0.219]
0,15
[0.006]
0.5-14 NPSM
conduit thread
DTE6-2RN28
DT,
DPDT
B,
10 A
-
7,92
[0.312]
5,56
[0.219]
4,19
[0.165]
Double pole
applications
BZE6-2RN62
BZ,
SPDT
A,
0,83 to 1,95
15 A
[3 to 7]
-
18,24
[0.718]
21,29
[838]
5,82
[0.229]
BZE6-2RN18
BZ,
SPDT
A,
15 A
1,95 N max.
[7.0 oz
max.]
-
15°
20° Ref
-
BZE6-2RN1872
BZ,
SPDT
H,
1A
1,95 N max.
[7.0 oz
max.]
-
15°
20° Ref
-
BZE6-2RN4
BZ,
SPDT
A,
2,78 to 5,57
80,0 Ref [3.15]
15 A
[10 to 20]
4,83
[0.188]
5,56
[0.219]
0,15
[0.006]
Catalog Listing
BZE6-2RN2
BZE6-2RN2-S
BZE6-2RN234
BZE6-2RN272
Roller Lever
One-way Roller
Lever
DTE6-2RN2
5,56 to10
[20 to 36]
Low-force Rod
Lever
Gold-plated
contacts
Coil-spring Wobble
Manual Palm Button
sensing.honeywell.com
9
E6/V6 Series
Pretravel
mm [in] max.
Over Travel
mm [in] min.
Differential
Travel
mm [in] max.
Operate Point
mm [in]
Operate Force
N [oz]
Electrical
Rating [page 6]
Catalog Listing
Switch type,
Circuitry
Table 6. continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
1,98
[0.078]
5,56
[0.219]
NA
Reset position:
53,19 [2.094] max.
56,70 ± 1,14
[2.232 ±
0.045]
1,98
[0.078]
4,75
[0.187]
NA
Reset position:
53,19 [2.094] max.
A,
4,45 N max.
15 A [16 oz max.]
71,42 Ref
[2.812 in.]
4,83
[0.188]
5,56
[0.219]
NA
Reset position:
50,40 ± 1,14
[1.984 ± 0.045]
A,
1,95 N max.
15 A [7.0 oz max.]
-
15°
20° Ref
NA
Reset position:
50,40 ± 1,14
[1.984 ± 0.045]
BZE6-RNX1
BZ,
SPDT
A,
1,67 to 5,56 43,64 ± 0,76
15 A
[6 to 20]
[1.718 ±0.030]
BZE6-RN80X2
BZ,
SPDT
A,
15 A
BZE6-RN2X1
BZ,
SPDT
BZE6-RN18X1
BZ,
SPDT
Comments
Pin Plunger w
Manual Reset
5,85 to 15,57
[21 to 56]
Inline roller plunger
w/ manual reset
Roller Lever w/
Manual Reset
Coil Spring Wobble
w/ Manual Reset
10
sensing.honeywell.com
MICRO SWITCH™ Medium-Duty Limit Switches
DIMENSIONS
Figure 2. Top pin plunger, side mount with boot seal
ref. 2,0 mm
[ref. 0.08 in]
Figure 3. Top roller plunger, side mount with boot seal
Ø 8,44 mm
[Ø 0.33 in]
23,4 mm
[0.92 in]
1/2-14 NPT
Threads
56,64 mm
[2.23 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
77,2 mm
[3.04 in]
21,1 mm
[0.83 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
19.0 mm
[0.75 in]
43,7 mm OP
[1.72 in OP]
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
21,1 mm
[0.83 in]
Figure 4. Cross roller plunger, side mount with boot seal
Figure 5. Roller lever, adjustable, side mount with boot seal
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
56,64 mm
[2.23 in]
39,6 mm
[1.57 in]
18,3 mm
[0.72 in]
19.0 mm
[0.75 in]
1/2-14 NPT
Threads
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
23,1 mm
[0.91 in]
53,1 mm
[2.09 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
77,2 mm [3.04 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
69,6 mm
[2.74 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
25,4 mm [1.00 in]
69,6 mm [2.74 in]
Figure 6. One-way roller lever, side mount with boot seal
]
6 in
1.5
3
18,3 mm
[0.72 in]
152,4 mm [6.0 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
18,3 mm
[0.72 in]
32,26 mm
[1.27 in]
53,1 mm
[2.09 in]
53,1 mm
[2.09 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
25,4 mm
[1.00 in]
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
m[
m
9,6
Figure 7. Rod lever, side mount with boot seal
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
sensing.honeywell.com
11
E6/V6 Series
Figure 8. Manual palm button, side mount with boot seal
m
8m
4
[1.4
Ø 7,11 mm [Ø 0.28 in]
5
36,
Figure 9. Coil wobble, side mount with boot seal
in]
38,1 mm
[1.50 in]
18,3 mm
[0.72 in]
108,97 mm
[4.29 in]
31,75 mm
[1.25 in]
149,35 mm
[5.88 in]
53,1 mm
[2.09 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
19.0 mm
[0.75 in]
1/2-14 NPT
Threads
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
Figure 10. Top pin plunger, reset, side mount with boot seal
Figure 11. Top roller plunger, reset, side mount with boot seal
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
Ø 8,44 mm
[Ø 0.33 in]
56,64 mm
[2.23 in]
1/2-14 NPT
Threads
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
25,4 mm
[1.00 in] 19.0 mm
53,1 mm [2.09 in]
[0.75 in]
1/2-14 NPT
Threads
25,4 mm 19.0 mm
[1.00 in] [0.75 in]
53,1 mm [2.09 in] 43,69 mm [1.72 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
77,2 mm [3.04 in]
Figure 12. Roller lever plunger, reset, side mount with boot seal Figure 13. Coil wobble plunger, reset, side mount with boot seal
39,6 mm
[1.57 in]
18,3 mm
[0.72 in]
Ø 7,11 mm [Ø 0.28 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
108,97 mm
[4.29 in]
23,1 mm
[0.91 in]
149,35 mm
[5.88 in]
53,1 mm
[2.09 in]
1/2-14 NPT
Threads
69,6 mm [2.74 in]
77,2 mm [3.04 in]
sensing.honeywell.com
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
12
53,1 mm [2.09 in]
25,4 mm
[1.00 in]
53,1 mm [2.09 in]
19.0 mm
[0.75 in]
19.0 mm
[0.75 in]
1/2-14 NPT
Threads
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
MICRO SWITCH™ Medium-Duty Limit Switches
BME6-2RQ
DTE6-2RQ
BZE6-2RQ8
BZE6-2RQ8-S
Inline Roller Plunger
BZE6-2RQ8722
BZE6-2RQ81
BZE6-2RQ81-S
BME6-2RQ81
Cross Roller
Plunger
DTE6-2RQ81
BZE6-2RQ2
BZE6-2RQ2-S
Roller Lever
DTE6-2RQ2
BZE6-2RQ28
DT,
DPDT
B,
10 A
BZ,
SPDT
BZ,
SPDT
DT,
DPDT
A,
15 A
A,
15 A
B,
10 A
BZ,
SPDT
A,
2,22 to 5,00
15 A
[8 to 18]
BZ,
SPDT
BZ,
SPDT
DT,
DPDT
A,
0,56 to 1,39
15 A
[2 to 5]
A,
0,56 to 1,39
15 A
[2 to 5]
B,
1,39 to 3,34
10 A
[5 to 12]
Differential
Travel
mm [in] max.
Pin Plunger
Over Travel
mm [in] min.
BZE6-2RQ72
Pretravel
mm [in] max.
BZE6-2RQ7
A,
15 A
A,
15 A
A,
15 A
H,
1A
G,
22 A
B,
10 A
A,
15 A
A,
15 A
H,
1A
A,
15 A
A,
15 A
G,
22 A
Operate Point
mm [in]
BZE6-2RQ-S
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BM,
SPDT
DT,
DPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
BM,
SPDT
Operate Force
N [oz]
BZE6-2RQ
Electrical
Rating [page 6]
Catalog Listing
Switch type,
Circuitry
Table 7. Order Guide • E6 Series Switches, Side Mount without Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
5,56 to 11,12
[20 to 40]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
2,50 to 3,61
[9 to 13]
6,67 to
13,34
[24 to 48]
2,78 to 5,00
[10 to 18]
2,78 to 5,00
[10 to 18]
2,78 to 5,57
[10 to 20]
38,1 ±0,76
[1.5 ±0.030]
38,1 ±0,76
[1.5 ±0.030]
38,1 ±0,76
[1.5 ±0.030]
38,1 ±0,76
[1.5 ±0.030]
38,1 ±0,76
[1.5 ±0.030]
47,88 ±0,76
[1.885 ±0.030]
49,61 ±1,14
[1.953 ±0.045]
49,61 ±1,14
[1.953 ±0.045]
49,61 ±1,14
[1.953 ±0.045]
49,61 ±1,14
[1.953 ±0.045]
49,61 ±1,14
[1.953 ±0.045]
49,61 ±1,14
[1.953 ±0.045]
0,38
[0.015]
0,38
[0.015]
0,38
[0.015]
0,38
[0.015]
0,38
[0.015]
3,81
[0.150]
0,38
[0.015]
0,38
[0.015]
0,38
[0.015]
0,38
[0.015]
0,38
[0.015]
0,38
[0.015]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
2,24
[0.088]
3,56
[0.140]
3,56
[0.140]
3,56
[0.140]
3,56
[0.140]
3,56
[0.140]
3,56
[0.140]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
1,52
[0.060]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
49,61 ±1,14
[1.953 ±0.045]
3,58
[0.141]
3,18
[0.125]
1,52
[0.060]
Double pole
applications
61,11 Ref
[2.406]
61,11 Ref
[2.406]
69,44 Ref
[2.734]
4,83
[0.188]
4,83
[0.188]
6,76
[0.266]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
0,15
[0.006]
0,15
[0.006]
4,19
[0.165]
0.5-14 NPSM
conduit thread
Double pole
applications
-
5,94
[0.234]
5,56
[0.219]
0,15
[0.006]
18,24
[0.718]
18,24
[0.718]
27,94
[1,100]
21,29
[0.838]
21,29
[0.838]
21,29
[0.838]
5,82
[0.229]
5,82
[0.229]
14,22
[0.560]
Comments
0.5-14 NPSM
conduit thread
#8 mounting screws
Gold-plated
contacts
Higher current ac
applications
Double pole
applications
0.5-14 NPSM
conduit thread
Gold-plated
contacts
0.5-14 NPSM
conduit thread
Higher current ac
applications
One-way Roller
Lever
BZE6-2RQ62
BZE6-2RQ62-S
Low-force Rod
Lever
DTE6-2RQ62
-
0.5-14 NPSM
conduit thread
Double pole
applications
sensing.honeywell.com
13
E6/V6 Series
Pretravel
mm [in] max.
Over Travel
mm [in] min.
Differential
Travel
mm [in] max.
BZE6-2RQ4
BZ,
SPDT
A,
2,78 to 5,00
15 A
[10 to 18]
-
-
5,56
[0.219]
0,15
[0.006]
BZE6-RQX2
BZ,
SPDT
A,
1,67 to 2,64
15 A
[6 to 9.5]
38,1 ±0,76
[1.5 ±0.030]
0,30
[0.012]
4,75
[0.187]
NA
Reset position:
46,84 [1.844] max.
BZE6-RQ8X2
BZ,
SPDT
A,
1,47 to 2,64 51,18 ± 1,14
15 A
[6 to 9.5]
[2.015 ±0.045]
0,30
[0.012]
3,56
[0.140]
NA
Reset position:
46,84 [1.844] max.
BZE6-RQ81X2
BZ,
SPDT
A,
1,47 to 2,64 51,18 ± 1,14
15 A
[6 to 9.5]
[2.015 ±0.045]
0,30
[0.012]
3,56
[0.140]
NA
Reset position:
46,84 [1.844] max.
BZE6-RQ2X2
BZ,
SPDT
A,
15 A
4,83
[0.188]
5,56
[0.219]
NA
Reset position:
46,84 [1.844] max.
Catalog Listing
Switch type,
Circuitry
Operate Point
mm [in]
Operate Force
N [oz]
Electrical
Rating [page 6]
Table 7, continued. Order Guide • E6 Series Switches, Side Mount without Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
Comments
Manual Palm Button
Pin Plunger w
Manual Reset
Inline Roller Plunger
w/ Manual Reset
Cross Roller
Plunger w/ Manual
Reset
Roller Lever w/
Manual Reset
14
sensing.honeywell.com
3,34
approx.
[12 oz ]
61,11 Ref
[2.406]
MICRO SWITCH™ Medium-Duty Limit Switches
DIMENSIONS
Figure 14. Top pin plunger, side mount
Figure 15. Top roller plunger, side mount
Ø 8,44 mm
[Ø 0.33 in]
23,4 mm
[0.92 in]
1/2-14 NPT
Threads
49,61 mm
[1.95 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
19.0 mm
[0.75 in]
38,1 mm
[1.50 in]
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
77,2 mm
[3.04 in]
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
69,6 mm
[2.74 in]
77,2 mm [3.04 in]
Figure 17. Roller lever, adjustable, side mount
Figure 16. Cross roller plunger, side mount
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
1/2-14 NPT
Threads
39,6 mm
[1.57 in]
18,3 mm
[0.72 in]
19.0 mm
[0.75 in]
49,61 mm
[1.95 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
1/2-14 NPT
Threads
42,9 mm
[1.69 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
23,1 mm
[0.91 in]
77,2 mm [3.04 in]
19.0 mm
[0.75 in]
25,4 mm
[1.00 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
Figure 18. One-way roller lever, side mount
6
1.5
m[
152,4 mm [6.0 in]
18,3 mm
[0.72 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
18,3 mm
[0.72 in]
32,26 mm
[1.27 in]
42,93 mm
[1.69 in]
19.0 mm
[0.75 in]
25,4 mm
[1.00 in]
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
1/2-14 NPT
Threads
42,93 mm
[1.69 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
6m
39,
Figure 19. Rod lever, side mount
in]
25,4 mm [1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
sensing.honeywell.com
15
E6/V6 Series
Figure 20. Manual palm button, side mount
46,74 mm [1.84 in]
31,75 mm
[1.25 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
46,74 mm [1.84 in]
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
23,1 mm
[0.91 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
25,4 mm
[1.00 in]
46,74 mm [1.84 in]
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
sensing.honeywell.com
25,4 mm
[1.00 in]
77,2 mm [3.04 in]
Figure 24. Roller lever, reset, side mount
42,9 mm
[1.69 in]
22,6 mm
[0.89 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
18,3 mm
[0.72 in]
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
1/2-14 NPT
Threads
49,61 mm
[1.95 in]
[0.75 in]
25,4 mm
[1.00 in] 19.0 mm
51,31 mm [2.02 in]
46,74 mm [1.84 in]
Figure 23. Cross roller plunger, reset, side mount
1/2-14 NPT
Threads
25,4 mm
[1.00 in]
16
69,6 mm [2.74 in]
77,2 mm [3.04 in]
Figure 22. Roller plunger, reset, side mount
39,6 mm
[1.57 in]
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
22,6 mm
[0.89 in]
25,4 mm
mm
[1.00 in] 19.0
[0.75 in]
42,93 mm
[1.69 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
18,3 mm
[0.72 in]
25,4 mm
[1.00 in]
38,1 mm
[1.50 in]
36
25,4 mm [1.00 in]
Ø 8,44 mm
[Ø 0.33 in]
38,1 mm [1.50 in]
4
1.4
m[
m
,58
Figure 21. Top pin plunger, reset, side mount
in]
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
MICRO SWITCH™ Medium-Duty Limit Switches
Switch type,
Circuitry
Electrical Rating
[page 6]
Operate Force
N [oz]
Operate Point
mm [in]
Pretravel
mm [in] max.
Over Travel
mm [in] min.
Differential
Travel
mm [in] max.
Table 8. Order Guide • V6 Series Switches, Flange Mount with Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
Comments
BZ,
SPDT
BZ,
SPDT
BZ,
SPDT
DT,
DPDT
A,
15 A
A,
15 A
A,
15 A
B,
10 A
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
2,50 to 6,67
[9 to 24]
7,23 to 16,4
[26 to 59]
69,09 ±1,52
[2.720 ±0.060]
69,09 ±1,52
[2.720 ±0.060]
69,09 ±1,52
[2.720 ±0.060]
71,42 ±0,76
[2.812 ±0.030]
1,98
[0.078]
1,98
[0.078]
1,98
[0.078]
2,79
[0.110]
5,56
[0.219]
5,56
[0.219]
5,56
[0.219]
3,18
[0.125]
0,05
[0.002]
0,05
[0.002]
0,05
[0.002]
1,52
[0.060]
0.5-14 NPSM
conduit thread
Low temperature
-40 °C [-40 °F]
Double pole
applications
BZV6-2RN80
BZ,
SPDT
A,
2,50 to 6,67 82,09 ±1,14
15 A
[9 to24]
[3.232 ±0.045]
1,98
[0.078]
5,56
[0.219]
0,05
[0.002]
BZV6-2RN81
BZ,
SPDT
A,
2,50 to 6,67 82,09 ±1,14
15 A
[9 to24]
[3.232 ±0.045]
1,98
[0.078]
5,56
[0.219]
0,05
[0.002]
BZV6-2RN2
BZ,
SPDT
A,
2,78 to 5,57
15 A
[10 to 20]
96,82 Ref
[3.812]
4,83
[0.188]
5,56
[0.219]
0,15
[0.006]
DTV6-2RN2
DT,
DPDT
B,
2,78 to 8,35
10 A
[10 to 30]
94,84 Ref
[3.734]
6,76
[0.266]
5,56
[0.219]
4,19
[0.165]
BZV6-2RN28
BZ,
SPDT
A,
2,22 to 5,56
15 A
[8 to 20]
-
5,94
[0.234]
5,56
[0.219]
0,15
[0.006]
BZV6-2RN62
BZ,
SPDT
A,
0,83 to 1,95
15 A
[3 to 7]
-
18,24
[0.718]
21,29
[0.838]
5,82
[0.229]
Catalog Listing
BZV6-2RN
BZV6-2RN-S
BZV6-2RN34
Pin plunger
DTV6-2RN
Inline Roller Plunger
Cross Roller
Plunger
Double pole
applications
Roller Lever
One-way Roller
Lever
Low-force Rod
Lever
sensing.honeywell.com
17
E6/V6 Series
BZ,
SPDT
A,
2,78 to 5,57
15 A
[10 to 20]
BZV6-RNX1
BZ,
SPDT
A,
1,67 to 5,56 69,09 ±1,52
15 A
[6 to 20]
[2.720 ±0.060]
Differential
Travel
mm [in] max.
BZV6-2RN4
Over Travel
mm [in] min.
A,
15 A
Pretravel
mm [in] max.
BZ,
SPDT
Operate Point
mm [in]
Electrical Rating
[page 6]
BZV6-2RN18
Catalog Listing
Operate Force
N [oz]
Switch type,
Circuitry
Table 8, continued. Order Guide • V6 Series Switches, Flange Mount with Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
1,95 N. max.
[7.0 oz max.]
-
15°
20° Ref
-
105,56 Ref.
[4.156]
4,83
[0.188]
5,56
[0.219]
0,15
[0.006]
1,98
[0.078]
4,78
[0.188]
NA
Comments
Coil-spring Wobble
Manual Palm Button
Pin Plunger w
Manual Reset
18
sensing.honeywell.com
Reset position:
26,97 [1.062] max.
MICRO SWITCH™ Medium-Duty Limit Switches
DIMENSIONS
Figure 25. Top pin plunger, flange mount with boot seal
2,0 mm
[0.08 in]
Figure 26. Top roller plunger, flange mount with boot seal
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
Ø 8,44 mm
[Ø 0.33 in]
82,04 mm
[3.23 in]
1/2-14 NPT
Threads
69,1 mm
[2.72 in]
2X Ø 4,37 mm
[Ø 0.172 in]
44,4 mm
[1.75 in]
1/2-14 NPT
Threads
2X Ø 4,37 mm
[Ø 0.172 in]
44,4 mm
[1.75 in]
22,6 mm
[0.89 in]
22,6 mm
[0.89 in]
10,7 mm
[0.42 in]
3,3 mm
[0.13 in]
25,4 mm
[1.00 in]
41,4 mm [1.63 in]
69,6 mm
[2.74 in]
3,3 mm
[0.13 in]
25,4 mm
[1.00 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
54,1 mm [2.13 in]
Figure 27. Cross roller plunger, flange mount with boot seal
Figure 28. Roller lever adjustable, flange mount with boot seal
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
56,64 mm
[2.23 in]
39,6 mm
[1.57 in]
18,3 mm
[0.72 in]
1/2-14 NPT
Threads
25,4 mm
[1.00 in]
53,1 mm
[2.09 in]
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
10,7 mm
[0.42 in]
3,3 mm
[0.13 in]
23,1 mm
[0.91 in]
69,6 mm [2.74 in]
41,4 mm [1.63 in]
77,2 mm [3.04 in]
54,1 mm [2.13 in]
1/2-14 NPT
Threads
2X Ø 4,37 mm
[Ø 0.172 in]
19.0 mm
[0.75 in]
19.0 mm
[0.75 in]
2X Ø 4,37 mm
[Ø 0.172 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
25,4 mm
[1.00 in]
3,3 mm
[0.13 in]
22,6 mm
[0.89 in]
25,4 mm
[1.00 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
Figure 29. One-way roller lever, flange mount with boot seal
18,3 mm
[0.72 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
18,3 mm
[0.72 in]
32,26 mm
[1.27 in]
53,1 mm
[2.09 in]
53,1 mm
[2.09 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
2X Ø 4,37 mm
[Ø 0.172 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
10,7 mm
[0.42 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
19.0 mm
[0.75 in]
1/2-14 NPT
Threads
2X Ø 4,37 mm
[Ø 0.172 in]
25,4 mm
[1.00 in]
3,3 mm
[0.13 in]
152,4 mm [6.0 in]
]
6 in
1.5
m[
6m
39,
Figure 30. Rod lever, flange mount with boot seal
25,4 mm
[1.00 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
3,3 mm
[0.13 in]
22,6 mm
[0.89 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
sensing.honeywell.com
19
E6/V6 Series
Figure 31. Manual palm button, flange mount with boot seal
58
36,
mm
Figure 32. Coil wobble, flange mount with boot seal
]
4 in
Ø 7,11 mm [Ø 0.28 in]
[1.4
38,1 mm
[1.50 in]
18,3 mm
[0.72 in]
108,97 mm
[4.29 in]
31,75 mm
[1.25 in]
149,35 mm
[5.88 in]
53,1 mm
[2.09 in]
1/2-14 NPT
Threads
1/2-14 NPT
Threads
25,4 mm
[1.00 in]
25,4 mm
[1.00 in]
22,6 mm
[0.89 in]
3,3 mm
[0.13 in]
25,4 mm
[1.00 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
Figure 33. Top pin plunger, reset, flange mount with boot seal
10,7 mm
[0.42 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
2X Ø 4,37 mm
[Ø 0.172 in]
25,4 mm
[1.00 in]
53,1 mm [2.09 in]
43,69 mm [1.72 in]
Ø 8,44 mm
[Ø 0.33 in]
22,6 mm
[0.89 in]
3,3 mm
[0.13 in]
25,4 mm
[1.00 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
20
sensing.honeywell.com
2X Ø 4,37 mm
[Ø 0.172 in]
19.0 mm
[0.75 in]
19.0 mm
[0.75 in]
2X Ø 4,37 mm
[Ø 0.172 in]
25,4 mm
[1.00 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
3,3 mm
[0.13 in]
22,6 mm
[0.89 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
MICRO SWITCH™ Medium-Duty Limit Switches
Pretravel
mm [in] max.
Over Travel
mm [in] min.
Differential
Travel
mm [in] max.
BZV6-2RQ
BZ,
SPDT
A,
2,50 to 3,61
15 A
[9 to 13]
63,50 ±1,14
[2.50 ±0.045]
0,38
[0.015]
5,56
[0.219]
0,05
[0.002]
BZV6-2RQ8
BZ,
SPDT
A,
2,50 to 3,61 75,01 ±1,52
15 A
[9 to 13]
[2.953 ±0.060]
0,38
[0.015]
3,56
[0.140]
0,05
[0.002]
BZV6-2RQ81
BZ,
SPDT
A,
2,50 to 3,61 75,01 ±1,52
15 A
[9 to 13]
[2.953 ±0.060]
0,38
[0.015]
3,56
[0.140]
0,05
[0.002]
BZV6-2RQ2
BZ,
SPDT
A,
2,78 to 5,00
15 A
[10 to 18]
86,51 Ref
[3.406]
4,83
[0.188]
5,56
[0.219]
0,15
[0.006]
BZV6-2RQ62
BZ,
SPDT
A,
0,56 to 1,39
15 A
[2 to 5]
-
18,24
[0.718]
21,29
[0.838]
5,82
[0.229]
Catalog Listing
Switch type,
Circuitry
Operate Point
mm [in]
Operate Force
N [oz]
Electrical
Rating [page 6]
Table 9. Order Guide • V6 Series Switches, Flange Mount without Boot Seal
For catalog listings not shown, please contact your Honeywell distributor or representative.
Comments
Pin plunger
Inline Roller Plunger
Cross Roller
Plunger
Roller Lever
Low-force Rod
Lever
sensing.honeywell.com
21
E6/V6 Series
DIMENSIONS
Figure 34. Top pin plunger, flange mount
Figure 35. Top roller plunger, flange mount
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
Ø 8,44 mm
[Ø 0.33 in]
74,93 mm
[2.95 in]
1/2-14 NPT
Threads
63,5 mm
[2.50 in]
2X Ø 4,37 mm
[Ø 0.172 in]
44,4 mm
[1.75 in]
1/2-14 NPT
Threads
2X Ø 4,37 mm
[Ø 0.172 in]
44,4 mm
[1.75 in]
22,6 mm
[0.89 in]
22,6 mm
[0.89 in]
3,3 mm
[0.13 in]
25,4 mm
[1.00 in]
10,7 mm
[0.42 in]
69,6 mm
[2.74 in]
41,4 mm [1.63 in]
3,3 mm
[0.13 in]
25,4 mm
[1.00 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
54,1 mm [2.13 in]
Figure 36. Cross roller plunger, flange mount
Figure 37. Roller lever adjustable, flange mount
Ø12,7 mm [0.50 in] x
4,6 mm [0.18 in] W
roller
74,9 mm
[2.95 in]
39,6 mm
[1.57 in]
18,3 mm
[0.72 in]
1/2-14 NPT
Threads
2X Ø 4,37 mm
[Ø 0.172 in]
22,6 mm
[0.89 in]
3,3 mm
[0.13 in]
25,4 mm
[1.00 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
152,4 mm [6.0 in]
1/2-14 NPT
Threads
19.0 mm
[0.75 in]
2X Ø 4,37 mm
[Ø 0.172 in]
25,4 mm
[1.00 in]
3,3 mm
[0.13 in]
22,6 mm
[0.89 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
22
sensing.honeywell.com
22,6 mm
[0.89 in]
10,7 mm
[0.42 in]
69,6 mm [2.74 in]
77,2 mm [3.04 in]
25,4 mm
[1.00 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
18,3 mm
[0.72 in]
42,93 mm
[1.69 in]
2X Ø 4,37 mm
[Ø 0.172 in]
25,4 mm
[1.00 in]
3,3 mm
[0.13 in]
Figure 38. Rod lever, flange mount
1/2-14 NPT
Threads
42,9 mm
[1.69 in]
41,4 mm [1.63 in]
54,1 mm [2.13 in]
23,1 mm
[0.91 in]
19.0 mm
[0.75 in]
44,4 mm
[1.75 in]
Ø 19,0 mm [0.75 in] x
6,4 mm [0.25 in] W
roller
MICRO SWITCH™ Medium-Duty Limit Switches
E6/V6 REPLACEMENT PARTS
The metal bottom cover includes the insulator seal and two cover screws
The plunger seal boot includes the plunger seal and retaining hardware
The hardware packet includes mounting hardware and seal boot as noted in the tables
Table 10. Actuator with Boot Seal Replacement Parts
Cat. Listing
Bottom Cover
Plunger Seal
Boot1
Hardware Packet
Internal Basic
Switch
Actuator
BZE6-2RN
3PA13-E6
10PA2
1PA2*
BZ-2RQ77**
Integral to internal basic switch
BZV6-2RN
3PA14-V6
10PA2
1PA2*
BZ-2RQ77**
Integral to internal basic switch
BZE6-2RN7
3PA13-E6
10PA2
1PA46*2
BZ-2RN730**
Integral to internal basic switch
BZE6-2RN72
3PA13-E6
10PA2
1PA2*
BZ-2RQ7722**
Integral to internal basic switch
BZE6-2RN80
3PA13-E6
10PA2
1PA47
BZ-2RN784
Integral to internal basic switch
BZE6-2RN2
3PA13-E6
10PA2
1PA13*
BZ-2RN702**
6PA2*
BZV6-2RN2
3PA14-V6
10PA2
1PA13*
BZ-2RN702**
6PA2*
BZE6-2RN18
3PA13-E6
10PA2
-
BZ-2R-A2
6PA1953
BZV6-2RN18
3PA14-V6
10PA2
-
BZ-2R-A2
6PA1953
DTE6-2RN
3PA13-E6
10PA2
1PA2
DT-2R3-A7
8PA14
DTV6-2RN
3PA14-V6
10PA2
1PA2
DT-2R3-A7
8PA14
DTE6-2RN2
3PA13-E6
10PA2
-
DT-2R3-A7
6PA2*
DTV6-2RN2
3PA14-V6
10PA2
-
DT-2R3-A7
6PA2*
*Includes plunger seal boot
**Includes hardware packet
1. To order replacement low temperature plunger boot seal (switch code 34), specify 10PA1
2. 1PA46 hardware packet cannot be ordered separately. When BZ-2RN730 internal basic switch is ordered, the 1PA46 hardware packet
is included with internal basic switch.
3. To order replacement wobble actuator including internal threaded bushing, specify 6PA188-F
Table 11. Actuator without Boot Seal Replacement Parts
Cat. Listing
Bottom Cover
Hardware Packet
Internal Basic Switch
Actuator
BZE6-2RQ
3PA13-E6
1PA1
BZ-2RQ66
Integral to internal basic switch
BZV6-2RQ
3PA14-V6
1PA1
BZ-2RQ66
Integral to internal basic switch
BZE6-2RQ8
3PA13-E6
1PA19
BZ-2RQ784**
Integral to internal basic switch
BZV6-2RQ8
3PA14-V6
1PA19
BZ-2RQ784**
Integral to internal basic switch
BZE6-2RQ81
3PA13-E6
1PA19
BZ-2RQ785**
Integral to internal basic switch
BZV6-2RQ81
3PA14-V6
1PA19
BZ-2RQ785**
Integral to internal basic switch
BZE6-2RQ2
3PA13-E6
1PA3
BZ-2RQ68**
6PA1
BZV6-2RQ2
3PA14-V6
1PA3
BZ-2RQ68**
6PA1
**Includes hardware packet
sensing.honeywell.com
23
E6/V6 Series
This Honeywell datasheet supports the following MICRO SWITCH™ E6/V6 Series Limit Switch Listings
BZE6-2RN4
BZE6-2RN7
BZE6-2RN80
BZE6-2RQ2
BZE6-RN80X2
BZE6-2AQ
BZE6-2AQ8T
BZE6-2GN
BZE6-2RN
BZE6-2RN18
BZE6-2RN1809-5
BZE6-2RN1810
BZE6-2RN1812
BZE6-2RN183
BZE6-2RN185
BZE6-2RN185-WP
BZE6-2RN187
BZE6-2RN1872
BZE6-2RN18721
BZE6-2RN18-C3
BZE6-2RN19
BZE6-2RN191-S
BZE6-2RN193
BZE6-2RN196-F5
BZE6-2RN2
BZE6-2RN221
BZE6-2RN224
BZE6-2RN234
BZE6-2RN272
BZE6-2RN28
BZE6-2RN281
BZE6-2RN28-S
BZE6-2RN2-F3
BZE6-2RN2-F6
BZE6-2RN2-S
BZE6-2RN2-TW
BZE6-2RN34
BZE6-2RN37
BZE6-2RN39
BZE6-2RN5
BZE6-2RN51
BZE6-2RN62
BZE6-2RN72
24
sensing.honeywell.com
BZE6-2RN72-S
BZE6-2RN7-S
BZE6-2RN8
BZE6-2RN8034
BZE6-2RN81
BZE6-2RN-C
BZE6-2RN-F1
BZE6-2RN-F3
BZE6-2RN-F6
BZE6-2RN-FR
BZE6-2RN-M
BZE6-2RN-R
BZE6-2RN-S
BZE6-2RQ
BZE6-2RQ125
BZE6-2RQ136
BZE6-2RQ165
BZE6-2RQ168
BZE6-2RQ219
BZE6-2RQ241
BZE6-2RQ28
BZE6-2RQ2-S
BZE6-2RQ4
BZE6-2RQ5
BZE6-2RQ62
BZE6-2RQ62-S
BZE6-2RQ7
BZE6-2RQ72
BZE6-2RQ8
BZE6-2RQ81
BZE6-2RQ814
BZE6-2RQ81-S
BZE6-2RQ841-BP
BZE6-2RQ8722
BZE6-2RQ8-S
BZE6-2RQ9
BZE6-2RQ9-S
BZE6-2RQ-S
BZE6-3RN
BZE6-3RN18150-C
BZE6-3RN2153
BZE6-3YN2
BZE6-3YNP
BZE6-3YNT
BZE6-3YQ9
BZE6-3YQT
BZE6-7RN
BZE6-7RN18
BZE6-7RN1812
BZE6-7RN51
BZE6-7RN8051
BZE6-7RNT
BZE6-7RQ8
BZE6-7RQ9
BZE6-7RQ9T
BZE6-RN
BZE6-RN18X1
BZE6-RN18X2
BZE6-RN18X3
BZE6-RN2X1
BZE6-RNX1
BZE6-RNX12
BZE6-RNX17
BZE6-RQ
BZE6-RQ2
BZE6-RQ2X2
BZE6-RQ71
BZE6-RQ81X2
BZE6-RQ8X2
BZE6-RQ8X4
BZE6-RQ9
BZE6-RQX2
BZV6-2RN
BZV6-2RN18
BZV6-2RN2
BZV6-2RN28
BZV6-2RN34
BZV6-2RN4
BZV6-2RN62
BZV6-2RN80
BZV6-2RN81
BZV6-2RN-C
BZV6-2RN-S
BZV6-2RQ
BZV6-2RQ2
BZV6-2RQ39
BZV6-2RQ62
BZV6-2RQ8
BZV6-2RQ81
BZV6-2RQ9
BZV6-7RN
BZV6-7RN2T
BZV6-RNX1
10PA1
10PA2
19PA22-E6
3PA13-E6
3PA14-V6
6PA140-E6
6PA147-E6
6PA148-E6
6PA187-E6
BME6-2RN
BME6-2RN2
BME6-2RN373
BME6-2RQ
BME6-2RQ171
BME6-2RQ173
BME6-2RQ273
BME6-2RQ81
DTE6-2RN
DTE6-2RN2
DTE6-2RN28
DTE6-2RN281
DTE6-2RN4
DTE6-2RN80
DTE6-2RN8034-M
DTE6-2RQ
DTE6-2RQ2
DTE6-2RQ62
DTE6-2RQ81
DTE6-2RQ9
DTV6-2RN
DTV6-2RN2
DTV6-2RN4
HSE6-3RNT2
MICRO SWITCH™ Medium-Duty Limit Switches
ADDITIONAL INFORMATION
The following associated literature is available on the Honeywell web
site at sensing.honeywell.com:
• Product installation instructions
• Product range guide
• Product nomenclature tree
• Product application-specific information
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
– Limit and enclosed switch reference standards
WARNING
– Application note: Machine tool application guide
– Application note: Industrial machinery switch guide
MISUSE OF DOCUMENTATION
•
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge those
items it finds defective. The foregoing is buyer’s sole remedy
and is in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
sensing.honeywell.com
25
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
002383-2-EN IL50 GLO
December 2014
Copyright © 2014 Honeywell International Inc. All rights reserved.