DUXL Series
Sursense™ Ultra Low
Silicon Pressure Sensors
DESCRIPTION
The DUXL Series sensors provide a ratiometric millivolt output
The SURSENSE™ line of ultra low pressure sensors is based
and are housed in a low profile miniature ported package.
upon a proprietary technology designed to reduce all output
These sensors are intended for those applications where
offset or common mode errors.
customized external signal conditioning is required or available
from other sources. The low profile outline is ideal for portable
These sensors use a silicon micromachined sensing element
applications where small size is critical.
which features a unique stress concentration enhanced
structure to provide a highly stable linear output that is
Product is patented by US patent 6023978
proportional to applied pressure. Output offset errors due to
changes in temperature, warm-up, long term stability and
position sensitivity have all been significantly reduced when
compared to conventional sensors.
FEATURES
POTENTIAL APPLICATIONS
•
Position sensitivity to ±5 mV/g, typical
•
Hand held instrumentation
•
Operating temperature range -25 °C to 85 °C
•
Airflow controllers
[-13 °F to 185 °F]
•
Medical monitors
Available in gage and differential pressure ranges
•
Smart microvalves and switches
•
Level indicators
•
DUXL Series
ELECTRICAL SPECIFICATIONS (At 4.5 Vdc Excitation 25 °C [77 °F].)
Characteristic
Min.
Typ.
Max.
Unit
Excitation voltage
3.0
4.5
8.0
Vdc
(1)
Span except DUXL01D, DUXL05D
15
30
45
mV
(1)
Span DUXL01D
4.0
6.0
8.0
mV
(1)
Span DUXL05D
15
22.5
30
mV
Null
-10
0
10
mV
(2)
100
Offset temperature shift 0 °C to 50 °C [32 °F to 122 °F]
µV
−
−
(2)
100
Span temperature shift 0 °C to 50 °C [32 °F to 122 °F]
µV
−
−
(3)
Linearity, hysteresis error
-0.5
0.1
0.5
% span
Temperature coefficient of resistance
2600
ppm/°C
−
−
Temperature cCoefficient of sensitivity
-2200
ppm/°C
−
−
Operating temperature
-25 [-13]
85 [185]
°C [°F]
−
Storage temperature
-40 [-40]
125 [257]
°C [°F]
−
4
Offset warm-up shift
10
µV
−
−
Offset position sensitivity (±1 g) DUXL01D, DUXL05D
15
µV
−
−
Offset position sensitivity (±1 g) DUXL10D
10
µV
−
−
Offset position sensitivity (±1 g) DUXL20D, DUXL30D
5
µV
−
−
±100
Offset long term stability (1 year)
µV
−
−
Input resistance
2.0
kΩ
−
−
Notes:
1. The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 1.0 Vdc to 6.0 Vdc.
2. Shift is relative to 25 °C [77 °F]
3. Measured at ½ full scale operating pressure using BFSL
4. Shift is within the first hour of excitation applied to the device.
PRESSURE RATINGS (In H2O by Catalog Listing)
Characteristic
Operating pressure range
Maximum overpressure
Common mode
2
www.honeywell.com/sensing
01D
1.0
100
50
05D
5.0
100
50
10D
10.0
150
50
20D
20.0
200
50
30D
30.0
300
50
Sursense™ Ultra Low Silicon Pressure Sensors
MOUNTING DIMENSIONS (For reference only: mm (in).)
EQUIVALENT CIRCUIT
Pinout
1. –Vdc supply
2. +Vdc output
3. +Vdc supply
4. –Vdc output
MEDIA COMPATIBILITY: Clean, dry gases only
Port A: Media must be compatible with nylon housing,
epoxy adhesive and silicon.
Port B: Media must be compatible with nylon housing,
epoxy adhesive and silicon
PRESSURE COMPATIBILITY
Measures differential or gage pressure and vacuum. Pressure may be applied to either port. For pressure to the low
pressure port, the output polarity is reversed.
Honeywell Sensing and Control
3
ORDER GUIDE
WARNING
WARNING
PERSONAL INJURY
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
•
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
008052-3-EN IL50 GLO Printed in USA
July 2007
© 2007 Honeywell International Inc. All rights reserved.
很抱歉,暂时无法提供与“DUXL01D”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+2224.452441+278.22804
- 10+1466.3875210+183.41148