APPLICATIONS
LT •
HALF INCH DIAMETER LINEAR POSITION TRANSDUCER
The Model LT is a small diameter linear position transducer that is
rugged enough to withstand the hostile environment of the factory. Using
a proprietary dual wiper and the MystR® conductive plastic film the LT
provides usable output at high vibration levels for long periods. The LT
transducers use precious metal wipers to further enhance reliability. The
LT can be provided with shaft seals for spray of hose.
Intrinsically Safe for Class I, II, and III Division 1, Groups A, B,
C, D, E, F and G for Hazardous (indoor/outdoor) NEMA 4 locations.
V max = 30 V, I max = 100 mA, Ci = 0, uF, Li, = 0 mH.
•
•
•
•
•
•
•
•
BENEFIT
0.50 inch diameter
Dual wiper design
Extruded wiper block guides
MystR® plastic element
Anodized extruded aluminum housing
Stainless steel shaft
Precious metal contact
Absolute continuous measurement
•
•
•
•
•
•
•
•
Fits into tight spaces, clamps easily to cylinders
Improves shock and vibration performance
Smooth quiet motion; extends operating life
Tested up to one billion operations
Tolerates clamping loads
Full performance in hostile environments
Low noise level over entire life
Accurate position at power up
HOW TO ORDER
LTS
05
N
05K
F
5
C
Model
Termination
LTS = Standard
LTW = Water Resistant
Electrical
Travel*
Unit of
Measure
C = Cable
Shaft
5 = 4-40 Thread
01
02
03
04
05
=
=
=
=
=
1000
2000
3000
4000
5000
06
07
08
09
10
=
=
=
=
=
6000
7000
8000
9000
10000
Linearity
B = 0.1%
F = 1.0%
1000, 2000, 3000, 4000, 5000,
6000, 7000, 8000, 9000, 10000
N = Inches
Note: Not all combinations are available. Minimum quantity orders apply. Contact the factory for more details.
* Note: The Electrical Travel correlates to the Total Resistance (Ohms).
Total
Resistance*
MODEL LT
FEATURES
HALF INCH DIAMETER LINEAR POSITION TRANSDUCER
•
MEDICAL EQUIPMENT
•
HOSPITAL BEDS
•
LINEAR ACTUATORS
•
ANIMATED
CHARACTERS
•
GAUGING
•
WOODWORKING
GUIDES
•
FLUID FLOW METERS
•
SEISMOLOGY
•
SEMI CONDUCTOR
PROCESSING
MODELS LT
•
HALF INCH DIAMETER LINEAR POSITION TRANSDUCER
TECHNICAL SPECIFICATIONS
MECHANICAL
Total Mechanical Travel
1.05 to 10.05 in. (min)
26.7 to 255.3 mm (min)
Starting Force
xx.xx = inches
(xx.x) = mm
1.0 oz (max)*
Shock
50 g 11 ms half sine
Vibration
Life
DIMENSIONS
Housing Length 'X'
(Electrical Travel +1.50 [38.1])
#28 Jacketed Cable
6.0 (152.4) Long Min
20 g rms 5 Hz to 2 KHz
1" [25.4]
(Retracted)
¯1/8"
[3.17]
One Billion dither operations
¯1/2"
[12.7]
ELECTRICAL
Electrical Travel
(1 inch increments)
1 to 10 in.
(25.4 to 254.0 mm)
Total Resistance
1000 Ohms per inch
electrical travel
Operating Temperature
Shaft
Extended
-40° to 80°C
(-40° to 176°F)
Resolution
(Red)
V-in
(Black)
Ground
±20%
Resistance Tolerance
Insulation Resistance
#4-40 UNC-2A
Thd x .50 (12.7) Long
±1.0%
Independent Linearity **
(Brown)
V-out
Infinite
Connect to High Impedance Circuit
500 M Ohms @ 500 Vdc
Dielectric Strength
1000 V rms
Model
Electrical Travel
in inches
Total Resistance
Ohms
Housing Length
‘X’ in inches
Weight
in grams
LTS01 or LTW01
1.0
1000
2.5
20
LTS02 or LTW02
2.0
2000
3.5
26
LTS03 or LTW03
3.0
3000
4.5
31
LTS04 or LTW04
4.0
4000
5.5
43
LTS05 or LTW05
5.0
5000
6.5
45
Caution: Do not test on an Ohm Meter on the Rx 1 scale or other current devices.
LTS06 or LTW06
6.0
6000
7.5
48
Caution: Excessive Wiper Current can cause Output errors or damage.
LTS07 or LTW07
7.0
7000
8.5
51
Caution: Zero shaft side load is recommended to achieve maximum life.
LTS08 or LTW08
8.0
8000
9.5
57
LTS09 or LTW09
9.0
9000
10.5
62
LTS10 or LTW10
10.0
10000
11.5
68
Max. Applied Voltage
Backlash
30 Vdc
0.0002 in. max
很抱歉,暂时无法提供与“F58000138”相匹配的价格&库存,您可以联系我们找货