Relialign™ Commercial Door Interlock Switch
001042
CDI Series
Issue 4
Datasheet
FEATURES
DESCRIPTION
Similar in design to the RDI Series, the Relialign CDI Door
Interlock Series is also an electromechanical device designed
for use in commercial applications where swing/hinge door
applications are in service. This Relialign Series design
incorporates a “mechanical lock” feature (power-to-unlock
solenoid) rather than a solenoid lock (de-energize solenoid to
unlock). The mechanical lock prevents the swing door from
accidently being opened if no power is present to the system or
a temporary power loss occurs. A manual override is integrated
into the interlock for emergency use.
The Relialign CDI Series solenoid circuit is further refined to
include integral switches which permit power to be applied
to the solenoid “only” when unlocking the door. This unique
solenoid circuit may reduce the complexity of the host
controller and extend the life of the solenoid, since power is
applied only when the door is beginning to open.
• Certified to applicable sections of ASME A17.1, ASME A18.1,
and UL 104
• Two separate independent switches to provide door
closed and door locked; factory wired for series or parallel
configurations
• No exposed switch contacts
• Key-to cam engagement design and snap action switches
minimize nuisance stops
• Rugged die-cast metal housing with electrostatic epoxy
coating for enhanced durability and choice of several colors
• Life of one million cycles minimum
• Solenoid accepts 24 Vac or Vdc
• Electrical connection choice of terminal strip or RJ-45 Cat 5
termination
• Required to mount in vertical position
POTENTIAL APPLICATIONS
USA: Swing/Hinge Doors
Commercial
& residential
elevators
Commercial
& residential
dumbwaiters
Platform/
material lifts
Mobility
impaired lifts
Canada: Swing/Hinge Doors
VALUE TO CUSTOMERS
• Certified to ASME and UL codes
• Easier installation with terminal strip or Cat 5 wire
connection
• Interlock accepts for 24 Vac or 24 Vdc signal
• Internal custom control of solenoid for increased life which
may reduce complexity of host controller and potential “time
outs” for door interlock from host controller
DIFFERENTIATION
• Exceeds commercial pull force requirement of 675 lb with a
2X margin with use of high strength stainless steel solenoid
plunger, cam, and key
• No exposed or open electrical contacts
• White electrostatic epoxy finish on metal housing to
harmonize with equipment architecture
Sensing and Internet of Things
Commercial
& residential
elevators
Commercial
& residential
dumbwaiters
Platform/
material lifts
PORTFOLIO
Honeywell also manufactures a Residential Door Interlock
(RDI) for commercial applications.
Relialign Commercial Door Interlock Switches, CDI Series
Table 1. Specifications
Characteristic
Parameter
Product type
Relialign Electromechanical Door Interlock, CDI series
Mounting
Vertical mounting required for gravity to operate de-energized solenoid plunger
Interlock override option
Certifications
Mechanical override standard on CDI door interlocks
ANSI/ASME, cULus
ANSI/ASME A17.1 (Safety Code for Elevators & Escalators)
ANSI/ASME A18.1 (Safety Standard for Platform Lifts and Stairway Chairlifts)
UL 104 (Standard for Elevator Door Locking Devices)
CAN/CSA B44 (Safety Code for Elevators & Escalators)
Die-cast metal housing with zinc phosphate treatment & electrostatic epoxy coating
Stainless steel
Exceeds 675 lbs pull force requirement by a 2x factor
Two separate independent switches; one switch for door closed, one switch for door locked
Factory wired per customer specification in parallel or series for door closed and door locked
24 Vac or 24 Vdc
AC, 0.35 A max; DC 0.2 A max
MICRO SWITCH snap action
Terminal strip or RJ-45 Cat 5
1,000,000 cycles minimum
4 ⁰C to 38 ⁰C [40 ⁰F to 100 ⁰F]
-40 ⁰C to 60 ⁰C [-40 ⁰F to 140 ⁰F]
Reference standards
Housing material
Key material
Key override force
Door indication
Wiring for door indication
Supply voltage
Supply current
Internal switches
Electrical connection
Electrical life
Operating temperature
Storage temperature
Figure 1. Design Features
Product listings right
or left hand installation
Terminal strip interface to
PCB for quicker and easier
connection
Custom solenoid
design offers
Two snap-action basic
universal voltage for switches controlling solenoid.
Honeywell
ac and dc applications
metal cam design
Reduces complexity
provides positive snap action
of host controller
Die-cast metal
enclosure using
current Honeywell
limit switch technology
Metal key engagement ensures
door is held securely closed to
reduce alignment issues /
Manual override
nuisance stoppage
features as required by
Optional CAT 5
connector is available
for customer connection
2 sensing.honeywell.com
Snap-action door switch
used to monitor door
position (open / closed)
certain approval
agencies
Relialign Commercial Door Interlock Switches, CDI Series
Figure 2. Product Nomenclature
CDI
Switch Type
CDI Series
L
Relialign™
Commerical
Door Interlock R
R
B
S
1
W
Key Entry
Position
Solenoid
Type
Wiring
Connector
Color
Left
B
ac/dc
Right
P
Parallel
1
Terminal strip
W
White
S
Series
2
RJ-45 Category 5
connector
B
Black
3
Other
4
RJ-45 Category 5no solenoid switch
5
Terminal strip no solenoid switch
BR
Bronze
Specials
Two characters,
letters or numbers
to signify
customer name or
other unique features
of the product not
covered in the
nomenclature.
This field is
not required.
Table 2. Order Guide
Catalog LIstings
Description
CDILBP1W
CDI Commercial Door Interlock, left key entry, 24 Vac/dc solenoid, door closed and door locked with
parallel circuits, terminal strip connector, housing finish white
CDIRBP1W
CDI Commercial Door Interlock, right key entry, 24 Vac/dc solenoid, door closed and door locked with
parallel circuits, terminal strip connector, housing finish white
CDILBP2W
CDI Commercial Door Interlock, left key entry, 24 Vac/dc solenoid, door closed and door locked with
parallel circuits, RJ-45 Category 5 connector, housing finish white
CDIRBP2W
CDI Commercial Door Interlock, right key entry, 24 Vac/dc solenoid, door closed and door locked with
parallel circuits, RJ-45 Category 5 connector, housing finish white
CDILBP2BR
CDI Commercial Door Interlock, left key entry, 24 Vac/dc solenoid, door closed and door locked with
parallel circuits, RJ-45 Category 5 connector, housing finish architectural bronze
CDIRBP2BR
CDI Commercial Door Interlock, right key entry, 24 Vac/dc solenoid, door closed and door locked with
parallel circuits, RJ-45 Category 5 connector, housing finish architectural bronze
CDILBS1W
CDI Commercial Door Interlock, left key entry, 24 Vac/dc solenoid, door closed and door locked with series
circuits, terminal strip connector, housing finish white
CDIRBS1W
CDI Commercial Door Interlock, right key entry, 24 Vac/dc solenoid, door closed and door locked with
series circuits, terminal strip connector, housing finish white
CDILBS2W
CDI Commercial Door Interlock, left key entry, 24 Vac/dc solenoid, door closed and door locked with series
circuits, RJ-45 Category 5 connector, housing finish white
CDIRBS2W
CDI Commercial Door Interlock, right key entry, 24 Vac/dc solenoid, door closed and door locked with
series circuits, RJ-45 Category 5 connector, housing finish white
Table 3. Order Guide (Replacement Actuator Keys)
Catalog LIstings
Description
GKZ91
Replacement actuator key (finish, white)
GKZ92
Replacement actuator key (finish, black)
GKZ93
Replacement actuator key (finish, architectural bronze)
Sensing and Internet of Things
3
Relialign Commercial Door Interlock Switches, CDI Series
Figure 3. CDI Left-hand Mounting Dimensions • (For reference only) in
.85
1.99
2.79
7.375 ± .007
1.88
1.200
1.47
.500
.25
.76
2.03
2.29
(DOOR SURFACE)
(1.200)
2.71
7.125 ` .007
SWITCH
SHOWN
ACTUATED
8.457 +.040
-.022
(ACTUATOR LOCATION)
6.00
RUBBER
BUMPER
6.06
.40
.28
9.75
1.05
8.42
WINDOW
MID-POINT
.49
(PLUNGER
TRAVEL)
DOOR
SURFACE
.44
.30
.31
1.750
1.125
.65
2.5
FRONT OPENING
FOR EMERGENCY
OVER-RIDE
1.375
.500 TYP
4X Ø 0.190
2X .190
SIDE OPENING FOR
EMERGENCY OVER-RIDE
KEY (BOTH SIDES)
(.863)
1.15
1.44
NOTE: Interlock must be mounted vertically as illustrated.
4 sensing.honeywell.com
(.120)
(.260)
Relialign Commercial Door Interlock Switches, CDI Series
Figure 3. CDI Right-hand Mounting Dimensions • (For reference only) in
Ø 0.88
.75
.85
1.99
2.79
1.88
1.47
8.42
WINDOW
MID-POINT
2.03
2.29
(DOOR SURFACE)
1.200
.76
DOOR
SURFACE
(1.200)
2.71
.49
(PLUNGER
TRAVEL)
6.00
RUBBER
BUMPER
7.125
6.06
.40
.28
7.375
.44
9.75
.31
1.05
.30
2.5
1.750
.65
1.375
1.125
8.457 +.040
-.022
(ACTUATOR LOCATION)
FRONT OPENING
FOR EMERGENCY
OVER-RIDE
(.863)
1.15
1.44
SIDE OPENING FOR
EMERGENCY OVER-RIDE
KEY (BOTH SIDES)
2X .190
4X Ø 0.190
.500 TYP
(.120)
(.260)
NOTE: Interlock must be mounted vertically as illustrated.
Sensing and Internet of Things
5
Relialign Commercial Door Interlock Switches, CDI Series
Figure 5. Wiring Schematic Parallel Connection (CAT 5 connector)
ELECTRICAL
SCHEMATIC
7
Figure 6. Wiring Schematic Series Connection
(CAT 5 connector)
ELECTRICAL
SCHEMATIC
7
DOOR CLOSED
8
8
3
3
SOLENOID CONTROL
2
5
SOLENOID
DOOR LOCKED
-
Figure 7. CAT 5 Connector Pin
Details
PIN #1
PIN #8
DOOR CLOSED
DOOR LOCKED
SOLENOID CONTROL
2
SOLENOID
-
6
Figure 8. Wiring Schematic Parallel Connection
(6-pin Terminal)
Figure 9. Wiring Schematic Series Connection
(4-pin Terminal)
ELECTRICAL
SCHEMATIC
5
ELECTRICAL
SCHEMATIC
C
DOOR CLOSED
4
1
D
2
3
B
SOLENOID CONTROL
SOLENOID
DOOR LOCKED
-
DOOR CLOSED
DOOR LOCKED
SOLENOID CONTROL
A
SOLENOID
6
D C B A
6 5 4 3 2 1
6 sensing.honeywell.com
-
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty
applies unless agreed to otherwise by Honeywell in writing;
please refer to your order acknowledgement or consult your
local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all
other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While Honeywell may provide application assistance personally,
through our literature and the Honeywell web site, it is buyer’s
sole responsibility to determine the suitability of the product in
the application.
m WARNING
RISK TO LIFE OR PROPERTY
•
Never use this product for an application involving
serious risk to life or property without ensuring that
the system as a whole has been designed to address
the risks, and that this product is property rated and
installed for the intended use within the overall system.
Failure to comply with these instructions could result in
death or serious injury.
m WARNING
MISUSE OF DOCUMENTATION
•
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
For more information
Honeywell Sensing and Internet of
Things services its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing or the
nearest Authorized Distributor, visit
sensing.honeywell.com or call:
Asia Pacific
+65 6355-2828
Europe
+44 1698 481481
USA/Canada
+1-800-537-6945
Honeywell Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
honeywell.com
001042-4-EN | 4 | 03/19
© 2019 Honeywell International Inc. All rights reserved.